Search PubMedSearch

SEARCH · Search PubMed

Results for “physical performance”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

957 records · Page 14Linked to original sources

Diagnostic performance of machine learning models for malignant and non-malignant pleural effusion: Systematic review and meta-analysis.

BACKGROUND: Accurately distinguishing malignant pleural effusion (MPE) from non-malignant pleural effusion is clinically important, but the generalisability and methodological quality of machine-learning (ML) models remain uncertain. METHODS: We searched eight databases to 23 April 2026. Diagnostic performance was pooled using random-effects and Reitsma bivariate models, and study quality was assessed using PROBAST+AI. RESULTS: Forty-two studies were included; 17 contributed to the AUC meta-analysis and 14 to the bivariate analysis. The pooled AUC was 0.90 (95 % CI 0.85-0.94; 95 % prediction interval 0.62-0.98), with sensitivity of 0.80 (95 % CI 0.77-0.83) and specificity of 0.87 (95 % CI 0.79-0.92). Only nine studies reported external, temporal or independent validation. Externally validated studies had a lower pooled AUC than studies without external validation (0.83 vs 0.92), with lower specificity observed in the two externally validated studies contributing sensitivity and specificity data. All 42 development assessments had high overall quality concerns, and all 42 model evaluations were judged at high risk of bias. CONCLUSIONS: ML models showed good apparent accuracy for distinguishing MPE from non-MPE, but the evidence was limited by substantial heterogeneity, high risk of bias and scarce external validation. The pooled estimates reflect the average performance of different selected models rather than the expected accuracy of a single clinical test. ML models should be regarded as adjuncts to existing diagnostic pathways until they are confirmed by rigorous multicentre prospective external validation and clinical-impact studies.

Humans

An Assessment of Reliability Estimation Methods for Binomial Health Care Quality Measures.

We evaluated the performance of commonly used methods for estimating the reliability of binomial health care quality measures using simulated datasets spanning a range of performance score means and variances, numbers of entities, and patient sample sizes. For each simulation, reliability was estimated for all selected methods and compared with the known true reliability derived from the simulation parameters, with methods assessed on their accuracy and precision. Logistic regression with reliability estimated on the outcome scale demonstrated the highest accuracy and precision among all methods evaluated. The widely used Adams beta-binomial method performed poorly, although a modification recommended by Nieser and Harris substantially improved its performance. These approaches are applicable only to binomial measures. Among methods that can be applied to both binomial and continuous measures, permutation resampling of the Spearman rank correlation coefficient was the most accurate and precise, outperforming other commonly used approaches. Overall, for binomial quality measures, logistic regression on the outcome scale is the preferred method for reliability estimation, followed closely by the modified beta-binomial approach, while for non-binomial measures, permutation-based Spearman rank correlation appears to be the most suitable method.

Reproducibility of Results

Performance of Automated Hematology Analyzer Criteria in Detecting Peripheral Blood Smear Abnormalities: A Systematic Literature Review.

OBJECTIVES: Criteria for visual examination of stained peripheral blood smear (PBS) differ among institutions in the United States and internationally. In an effort to standardize review criteria, the International Consensus Group for Hematology Review (ICGHR) proposed in 2005 a consensus list of rules for CBC findings that should trigger a review of automated cell counter results and potentially lead to further testing or blood smear review. The primary aim of this paper is to report on the published literature in the past 20 years regarding PBS review criteria and their ability to identify relevant peripheral blood abnormalities. METHODS: We performed a systematic review of the published literature from 2005 to 2025 to investigate and summarize PBS review criteria and performance in the context of automated hematology analyzers in clinical laboratories. RESULTS: Of 5351 citations, 68 studies met our search criteria. These studies included 22 countries and all major hematology analyzer manufacturers. Marked variability was observed in study populations, analyzer flagging criteria, details of PBS visual review, definitions of a "positive" smear, and approaches to statistical data analysis. Across studies, the blast flag sensitivity ranged from 18% to 100% while the blast flag specificity ranged from 17% to 100%. Wide ranges in sensitivity/specificity were also seen for atypical and/or abnormal lymphocyte flags across studies. For studies analyzing the same patient population, less striking variation was seen across instruments. CONCLUSIONS: This systematic review provides a 20-year overview of the literature, highlighting significant variability in PBS review criteria, dependence on study design and hematology analyzer, and the importance of developing harmonized evidence-based guidelines.

Humans

Influence of microplastics on microalgal performance during wastewater polishing.

Microplastics (MPs) are emerging contaminants that are increasingly accumulating in aquatic ecosystems due to excessive anthropogenic activity and insufficient mitigation strategies, posing serious environmental and public health risks. Their impact on wastewater (WW) treatment processes remains poorly understood. This study evaluated the effects of five MPs commonly found in WW - polypropylene, polystyrene, polyamide, low-density polyethylene, and high-density polyethylene - on the physiology and bioremediation performance of the microalga Chlorella vulgaris in synthetic WW (SWW). Metabolic responses were assessed via esterase activity and intracellular reactive oxygen species (ROS), while nitrogen (N), phosphorus (P), and glucose removal were monitored to evaluate bioremediation efficiency. MPs inhibited esterase activity and elevated ROS levels, indicating oxidative stress. Nevertheless, C. vulgaris maintained a high bioremediation capacity (> 75 % N, > 60 % P, and > 70 % for glucose). Environmental conditions modulated microalga response to MPs exposure. Under N-limited conditions, C. vulgaris exhibited enhanced nutrient uptake and biomass production, but a 12 h/12 h light/dark photoperiod reduced N removal but stimulated glucose consumption via heterotrophic metabolism. In contrast, C-limited conditions exacerbated oxidative stress and compromised nutrient removal, resulting in residual concentrations exceeding legal limits. These findings highlight that environmental factors can either mitigate or exacerbate the physiological stress induced by MPs, ultimately affecting WW polishing. This work provides a comprehensive insight into the cellular and metabolic effects of MPs on microalgae and supports C. vulgaris as a resilient and sustainable approach for nutrient and carbon removal in MP-contaminated WW systems.

Microalgae

Prenatal exposure to indoor PM2.5 and children's cognitive performance at 4 years of age: an observational analysis from the UGAAR randomized controlled trial.

Outdoor fine particulate matter (PM2.5) concentrations during pregnancy are linked to reduced cognitive performance in children. We previously reported that portable HEPA filter air cleaners use during pregnancy improved children's mean full-scale IQ (FSIQ), but no previous studies have evaluated the relationship between indoor PM2.5 during pregnancy and FSIQ in childhood. We conducted an observational analysis using data from the Ulaanbaatar Gestation and Air Pollution Research (UGAAR) randomized controlled trial. Using a previously developed model of weekly indoor PM2.5 concentrations, we estimated the average concentrations in participants' homes over the full pregnancy and in each trimester. When the children were four years old, we measured FSIQ using the Wechsler Preschool and Primary Scale of Intelligence (WPPSI-IV). We used multiple linear regression to assess the adjusted relationships between interquartile range (IQR) contrasts in indoor PM2.5 during pregnancy and FSIQ among 475 mother-child dyads. An 8.8 μg/m3 increase in indoor PM2.5 concentration over the full pregnancy was associated with a reduction of 1.4 points (95% CI: -3.4, 0.6) in mean FSIQ. The strongest association between PM2.5 concentrations and FSIQ was in the first trimester, when a 19.1 μg/m3 contrast was associated with a 2.8-point reduction (95% CI: -5.7, 0.2) in mean FSIQ. Indoor PM2.5, particularly during early pregnancy, may impair brain development, leading to lower mean FSIQ scores in four-year old children. These results, combined with our previous analysis of HEPA filter air cleaners, indicate that reducing PM2.5 exposure during pregnancy has beneficial effects on children's cognitive performance.

Humans

Natural deep eutectic solvent in situ formation-based extraction method coupled to high-performance anion-exchange chromatography with pulsed amperometric detection for multiclass carbohydrates in hot pot bases.

A novel method was developed for the simultaneous extraction of fourteen multiclass carbohydrates from high-fat foods via the in situ formation of deep eutectic adducts from analytes and acetate ions. Different natural deep eutectic solvents (NADESs) composed of fructose and organic acids were tested as extraction solvents. A model NADES formulated with sodium acetate and fructose was characterized using Fourier transform infrared (FTIR) spectroscopy and hydrogen nuclear magnetic resonance (1H-NMR) spectroscopy. The critical extraction parameters were systematically optimized using multi-response surface methodology (MRSM) with a central composite design (CCD). The extract was analyzed using high-performance anion-exchange chromatography coupled with pulsed amperometric detection (HPAEC-PAD) using a sodium hydroxide-sodium acetate eluent, which did not require organic solvents. This approach exhibited good linearity over the concentration range of 0.02-10 mg L-1, with correlation coefficients (r) ranging from 0.9994 to 0.9999. The limits of detection and quantification were in the ranges of 0.06-0.42 mg kg-1 and 0.19-1.3 mg kg-1, respectively, which were significantly lower than those of liquid chromatography (LC). The protocol was successfully applied to the determination of fourteen carbohydrates in forty-five hotpot seasoning samples. The recoveries ranged from 86.3% to 104.1%, with relative standard deviations (RSDs) of 0.9-7.1%. By integrating multiple techniques, this strategy simplifies operations, shortens extraction time, and achieves baseline separation of three carbohydrate classes that exhibit poor resolution using a conventional LC method. This study describes an efficient procedure for the simultaneous determination of multiple trace-level carbohydrates in complex samples using HPAEC-PAD.

Journal Article

Clinical performance of two lithium disilicate CAD/CAM materials in posterior Class II inlay restorations: A 48-month randomised split-mouth clinical trial.

OBJECTIVES: To compare the clinical performance of Amber Mill (AM) and IPS e.max CAD (EM) lithium disilicate computer-aided design/computer-aided manufacturing (CAD/CAM) materials in posterior Class II inlay restorations and characterise their baseline properties. METHODS: Thirty-four adults received paired AM and EM posterior Class II inlays (68 restorations) in a triple-blind randomised split-mouth trial followed for 48 months. Restorations were evaluated at baseline and annually using revised World Dental Federation (FDI) criteria, with fracture and retention as the primary endpoint. Baseline characterisation included flexural strength, shear bond strength, translucency parameter, and scanning electron microscopy. McNemar, Wilcoxon signed-rank, Friedman, one-way analysis of variance, Tukey post hoc, and inter-rater agreement analyses were used. RESULTS: At 48 months, 18 paired participants were available for primary analysis. Failures occurred in 2 of 18 AM restorations and in 3 of 18 EM restorations, corresponding to success rates of 88.9% and 83.3%, respectively, with no significant between-material difference (McNemar p = 1.000). No catastrophic bulk ceramic fracture was observed. Secondary FDI scores remained mostly within the clinically acceptable range; marginal staining deteriorated over time in both groups (p < .001) without significant between-material differences. Baseline material testing showed significant material- and translucency-dependent differences in flexural strength, shear bond strength, and translucency. CONCLUSIONS: Within the limitations of the 48-month follow-up and the tested Class II inlay indication, AM showed clinical performance comparable to EM. Observed clinical complications were related to retention or marginal/interface behaviour. CLINICAL SIGNIFICANCE: For posterior Class II lithium disilicate CAD/CAM inlays, medium-term complications were mainly retention/interface-related, suggesting adhesive-interface durability may be as important as baseline ceramic strength.

Humans

Diagnostic performance of panfungal PCR on tissue specimens for the diagnosis of invasive fungal diseases: a systematic review and meta-analysis of the Fungal PCR Initiative (FPCRI).

UNLABELLED: Invasive fungal diseases are difficult to diagnose because of the limited sensitivity of culture. Panfungal PCR amplicon sequencing assays (targeting ribosomal RNA, such as 18S, 28S, ITS) are recommended for fungal identification in histopathology samples showing fungal elements. However, data describing its overall performance and consistency are lacking. This systematic literature review and meta-analysis assessed the performance of panfungal PCR on formalin-fixed paraffin-embedded (FFPE) and non-fixed (fresh or frozen) tissue samples. A systematic literature search was performed to include studies reporting the use of panfungal PCR for fungal identification in FFPE or non-fixed tissue samples. PCR sensitivity and specificity were assessed using the reference standard of histopathology showing fungal elements. Quality assessment was performed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Pooled estimates were obtained using random-effects meta-analysis. Twenty-eight studies were included. In FFPE samples (18 studies, 852 samples), sensitivity and specificity were 75.4% (95% confidence interval [CI], 59.2-86.6) and 93.5% (70.2-98.9), respectively. Sensitivity in non-fixed samples (13 studies, 207 samples) was 86.5% (74.7-93.3), while specificity could not be assessed (insufficient data). Comparative analyses showed a significantly higher sensitivity of panfungal PCR over culture (88.2%; 76-94.7 vs 52.2%; 39-65, P = 0.001). Sub-analyses could not demonstrate the superiority of one PCR target over another due to limited data. Panfungal PCR exhibited adequate sensitivity and good specificity in FFPE samples. Sensitivity was even higher in non-fixed samples and largely superior to culture. Nevertheless, large interstudy variability was observed, warranting interlaboratory studies to define the optimal PCR target and standardized protocols. IMPORTANCE: Invasive fungal diseases are difficult to diagnose because of the low sensitivity of culture. Panfungal PCRs are widely used for fungal identification in tissue specimens but suffer from heterogeneous procedures and performance. This meta-analysis shows an acceptable sensitivity (75.4% and 86.5% in fixed and non-fixed samples, respectively) and good specificity (93.5%) of panfungal PCR, supporting its use, not only on histopathology-positive fixed samples but also in non-fixed samples concomitantly with other diagnostic tools (cultures and fungal-specific PCRs if available). These results provide a strong basis for further standardization of panfungal PCR techniques via interlaboratory assays to assess reproducibility and optimize analytical protocols. CLINICAL TRIALS: This study is registered with PROSPERO as CRD42023461148.

Humans

Engineering copper ferrite (CuFe2O4) nanocomposites for enhanced eco-friendly photocatalysis: a systematic critical review on mechanisms, performance, and environmental applications.

Water pollution caused by organic and inorganic contaminants, particularly dyes and pharmaceuticals, represents a major environmental challenge. Advanced oxidation processes based on photocatalysts have emerged as efficient and sustainable approaches for water and wastewater treatment. Copper ferrite (CuFe2O4) is considered a promising photocatalyst owing to its narrow bandgap, visible-light activity, chemical stability, and magnetic properties. Despite extensive experimental investigations, a comprehensive systematic comparison of CuFe2O4-based photocatalysts under diverse operational conditions has remained limited. In this study, a systematic review following PRISMA guidelines was conducted using studies published between January 2014 and November 2025 indexed in Scopus, PubMed, Web of Science, and ScienceDirect. From an initial pool of 397 studies, 98 articles met the inclusion criteria. Key parameters&#xa0;-&#xa0;including pollutant type, pH, catalyst dosage, initial pollutant concentration, irradiation time, light source, and degradation efficiency&#xa0;-&#xa0;were quantitatively compared to identify performance trends and operational optima. The results demonstrate that CuFe2O4-based nanocomposites, particularly heterojunction, Z-scheme, and S-scheme architectures combined with TiO2, g-C3N4, graphene, and metal oxides, achieve high degradation efficiencies (often >90&#x202f;%) for a wide&#xa0;range of organic pollutants and selected inorganic contaminants (e.g., Cr(VI)). Enhanced charge separation and suppressed electron-hole recombination were identified as the primary factors contributing to improved photocatalytic activity. In addition, the intrinsic magnetic properties of these&#xa0;nanocomposites enable facile catalyst recovery and reuse. In conclusion, CuFe2O4-based nanocomposites, especially those&#xa0;incorporating advanced heterojunction architectures, emerge as highly efficient and magnetically recoverable photocatalytic platforms for sustainable water and wastewater treatment, with strong potential for scalable implementation and real-wastewater applications.

Catalysis

Diagnostic performance of machine learning models versus established risk stratification for intracranial aneurysm rupture: a systematic review and bivariate meta-analysis.

BACKGROUND: Machine learning (ML) models have been proposed to improve the discrimination of intracranial aneurysm rupture status beyond established clinical risk stratification tools. However, reported performance is heterogeneous and the relative contribution of model architecture and feature dominance remains unclear. METHODS: We performed a Preferred Reporting Items for Systematic Reviews and Meta-Analyses-diagnostic test accuracy systematic review and diagnostic meta-analysis of studies evaluating ML models for intracranial aneurysm rupture discrimination. PubMed, Embase and CENTRAL were searched to February 2026. Sensitivity and specificity were pooled using a bivariate random-effects model, with summary receiver operating characteristic curves generated across training, internal testing and external validation datasets. Models were compared with regression-based approaches and Population, Hypertension, Age, Size of aneurysm, Earlier subarachnoid haemorrhage, Site of aneurysm (PHASES) scores. Subgroup and meta-regression analyses explored associations between algorithm family and feature domain. RESULTS: Sixty-two retrospective cohorts (29&#x2009;709 patients 209 models) met the inclusion criteria. In training datasets, pooled sensitivity and specificity for ML were 0.81 (95% CI 0.75 to 0.85)&#x2009;and 0.83 (0.80-0.86), with an area under the curve (AUC) of 0.878, exceeding PHASES (AUC 0.667). In testing datasets, ML retained higher discrimination (AUC 0.837) than regression models (0.806) and PHASES (0.646). In external validation, sensitivity was preserved (0.82), but specificity declined (0.66). Deep learning demonstrated the highest AUCs (training and testing). Incorporation of haemodynamic or radiomic features improved pooled discrimination relative to morphology alone. Evidence of small-study effects and mostly unclear Prediction Model Risk Of Bias Assessment Tool ratings were observed. CONCLUSIONS: ML approaches demonstrate higher pooled discrimination for aneurysm rupture status than conventional risk scores in retrospective datasets, but reduced external validation specificity and heterogeneity limit confidence for clinical translation. Prospective, externally validated, calibrated models are required before integration into routine cerebrovascular risk stratification.

Humans

Performance comparison of rapid and native barcoding methods for Oxford Nanopore sequencing of Poliovirus Viral Protein 1 (VP1) amplicons.

Accurate and timely sequencing of poliovirus is critical for global eradication efforts, particularly for molecular epidemiology based on the typing region of the genome, viral protein 1 (VP1). While Oxford Nanopore Technologies (ONT) sequencing has expanded capabilities for poliovirus surveillance, the relative performance of different ONT library preparation methods, including ligation-based (Native Barcoding) and transposase-based (Rapid Barcoding) approaches, has not been systematically evaluated. In this study, we compared rapid barcoding and native barcoding workflows for sequencing VP1 amplicons from 17 type 2 poliovirus-positive samples, each processed in triplicate. Native barcoding generated significantly more sequencing output, producing approximately 2.3-fold greater total read yield than rapid barcoding, and demonstrated higher run-to-run reproducibility (R2 = 0.979-0.998 vs. 0.847-0.929, respectively; p&#x202f;<&#x202f;0.001). In addition, native barcoding generated 80% of the total yield achieved by rapid barcoding within approximately 7&#x202f;h, whereas rapid barcoding required approximately 40&#x202f;h to reach the same output. Despite these differences, both methods produced identical VP1 consensus sequences across all samples, with comparable read quality (median per-base Q-scores of approximately Q17-Q18). Rapid barcoding provided substantial practical advantages, reducing hands-on library preparation time (55 vs. 200&#x202f;min) and per-sample cost ($12.82 vs. $16.54), while simplifying workflow and reducing technical complexity. These findings indicate that sequencing yield may not be a determinant of downstream analytical outcomes for poliovirus VP1 ONT sequencing. Rapid barcoding therefore represents a cost-effective and efficient approach for routine poliovirus surveillance, whereas native barcoding remains advantageous in applications requiring rapid data generation or maximal sequencing depth.

Poliovirus

Immersive virtual reality-assisted anatomy training improves endotracheal intubation performance in simulation: a randomized controlled trial among Chinese non-anesthesiology residents.

INTRODUCTION: This study aimed to compare immersive virtual reality (IVR)-assisted versus conventional anatomy training for teaching endotracheal intubation (ETI) to novice non-anesthesiology residents enrolled in China's Standardized Residency Training program. METHODS: A total of 90 non-anesthesiology residents without prior ETI experience were randomly assigned to either an IVR group receiving IVR-assisted anatomy training (n&#x2009;=&#x2009;45) or a control group receiving conventional anatomy training (n&#x2009;=&#x2009;45). All participants underwent a standardized teaching protocol. The primary endpoint was residents' ETI performance on a simulator, assessed using both the Global Rating Scale (GRS) and a task-specific checklist. The secondary endpoints included changes in written multiple-choice question (MCQ) scores and residents' evaluations of the course. RESULTS: In practical ETI assessments on a manikin, the IVR group achieved significantly higher scores on the task-specific checklist than the control group (90.34&#x2009;&#xb1;&#x2009;2.89 vs. 87.20&#x2009;&#xb1;&#x2009;3.29; p&#x2009;<&#x2009;0.001), whereas GRS scores were comparable between groups. Both groups showed significant post-training improvement in knowledge scores (p&#x2009;<&#x2009;0.001), with the IVR group showing a greater gain in theoretical knowledge (54.0% vs. 36.3%; p&#x2009;<&#x2009;0.001). Participants in the IVR group also expressed a stronger preference for their training method (80.8%) and reported higher levels of motivation, confidence, and enjoyment (all p&#x2009;<&#x2009;0.05). CONCLUSION: IVR-assisted anatomy training enhances the effectiveness of ETI training for novice non-anesthesiology residents, offering an interactive, engaging, and reproducible approach within China's Standardized Residency Training framework.

Humans

Diagnostic Performance of Machine Learning for Systemic Lupus Erythematosus: Systematic Review and Meta-Analysis.

BACKGROUND: Early and accurate diagnosis of systemic lupus erythematosus (SLE) and its organ involvement is essential. Previous reviews of machine learning (ML) in SLE combined heterogeneous tasks and validation strategies and may have overinterpreted model performance. OBJECTIVE: This study evaluated the diagnostic performance of ML and deep learning (DL) models for 3 clinically distinct SLE-related tasks: SLE classification or diagnosis, lupus nephritis (LN) diagnosis, and neuropsychiatric systemic lupus erythematosus (NPSLE) discrimination. We also assessed methodological quality and certainty of evidence. METHODS: PubMed, Embase, Cochrane Library, Web of Science, and IEEE Xplore were searched from January 2014 to April 2026. Eligible peer-reviewed diagnostic accuracy studies developed or validated ML or DL models for 1 of the 3 prespecified tasks, used an accepted reference standard, and provided data for a 2&#xd7;2 contingency table. Bivariate random-effects meta-analyses with the Hartung-Knapp-Sidik-Jonkman adjustment were used to pool sensitivity and specificity. We reported 95% prediction intervals (PIs), assessed risk of bias using the Quality Assessment of Diagnostic Accuracy Studies for Artificial Intelligence tool (QUADAS-AI; Viknesh Sounderajah [Imperial College London]), and evaluated certainty of evidence using the Grading of Recommendations Assessment, Development, and Evaluation framework for diagnostic test accuracy. RESULTS: Twenty-nine studies were included: 17 for SLE classification, 5 for LN diagnosis, and 7 for NPSLE discrimination. In the primary task-stratified analysis, pooled sensitivity was 0.91 (95% CI 0.86-0.94; 95% PI 0.56-0.99), and pooled specificity was 0.94 (95% CI 0.91-0.96; 95% PI 0.69-0.99), with low heterogeneity (I&#xb2;=23.9% and 22.9%, respectively). DL models showed a sensitivity of 0.93 and specificity of 0.95, compared with 0.88 and 0.94 for traditional ML models. Certainty of evidence was high for most analyses but low for LN diagnosis because of inconsistency and imprecision. All studies were retrospective, and only 9 of 29 (31%) performed independent external validation. Overall risk of bias was high or unclear in 22 of 29 (75.9%) studies. No study reported model calibration, decision-curve analysis, or net clinical benefit. CONCLUSIONS: ML models showed promising diagnostic accuracy across 3 distinct SLE-related tasks, but wide PIs, limited external validation, and pervasive risk of bias restrict conclusions about real-world generalizability. Prospective multicenter studies with standardized tasks and reference standards, independent external validation, and formal assessment of calibration and clinical utility are required before clinical implementation.

Humans

Comparison of the predictive performance of systemic immune-inflammation index and neutrophil-to-lymphocyte ratio for three-month poor functional outcome in ischemic stroke: a systematic review and meta-analysis.

INTRODUCTION: Ischemic stroke (IS) is a leading cause of global mortality and disability. Early and accurate prognosis is crucial for patient management. The neutrophil-to-lymphocyte ratio (NLR) and systemic immune-inflammation index (SII) are emerging inflammatory biomarkers; however, their relative predictive value for three-month poor functional outcome (modified Rankin Scale [mRS]&#x2009;>&#x2009;2) remains uncertain. METHODS: We systematically searched PubMed, Embase, Web of Science, and the Cochrane Library up to 20 July 2025, adhering to PRISMA guidelines. Observational studies reporting the association of SII or NLR with three-month poor outcome were included. Study quality was evaluated using the Newcastle-Ottawa Scale. Area under the curve (AUC), odds ratios (OR), and standardized mean differences (SMD) were pooled using random-effects models in Stata 16.0. RESULTS: Twenty-one studies involving 7520 IS patients were analysed. NLR demonstrated marginally superior discriminative ability compared to SII (AUC 0.71, 95% CI: 0.67-0.76 vs. 0.68, 95% CI: 0.64-0.71), though this difference was not statistically significant. Elevated NLR was significantly associated with poor outcome (OR = 1.26, 95% CI: 1.17-1.37, p&#x2009;<&#x2009;.001), whereas SII was not (OR = 1.00, 95% CI: 1.00-1.00, p&#x2009;=&#x2009;.384). Both markers showed moderate effect sizes (SMD: NLR = 0.69, SII = 0.72; p&#x2009;<&#x2009;.001). NLR performed better in non-intervention and Chinese subgroups, while SII exhibited consistent AUC values across treatment and ethnic subgroups. CONCLUSION: NLR and SII are accessible prognostic markers in IS. NLR demonstrates superior accuracy and a significant association with poor outcome, while SII shows greater stability across patient subgroups. Both may assist in risk stratification, in resource-limited settings.

Humans

Impact of neoprene wetsuits on lung volumes and work of breathing: implications for military diver safety and performance.

INTRODUCTION: Neoprene wetsuits may impose mechanical constraints on the chest wall, potentially altering respiratory function. This study investigated the impact of neoprene wetsuits on lung volumes, airway mechanics, and work of breathing (WOB) in healthy male divers. METHODS: A randomised crossover trial was conducted with 31 male divers at the Royal Netherlands Navy Diving Medical Centre. Participants underwent pulmonary function testing, including spirometry, body plethysmography, the forced oscillation technique (FOT), and diffusion capacity measurements, both with and without a hoodless standardised 5 mm neoprene full body wetsuit with a neoprene neck seal. Primary outcomes included changes in forced vital capacity (FVC), functional residual capacity (FRC), airway resistance (Raw), reactance (Xrs), and WOB. RESULTS: Wearing a neoprene wetsuit led to statistically significant reductions in FVC (2.8%, P < 0.05), forced expiration in one second (2.9%, P < 0.05), FRC (4.0%, P < 0.05), and expiratory reserve volume (10.9%, P < 0.05), alongside increases in inspiratory capacity and tidal volume. Raw increased significantly (P < 0.05), while the FOT revealed altered airway mechanics, evidenced by increased Xrs at multiple frequencies (P < 0.05). Diffusion capacity remained unchanged, suggesting preserved alveolar-capillary function. CONCLUSIONS: Neoprene wetsuits induce mechanically restrictive effects on the chest wall, reducing static and dynamic lung volumes and increasing WOB. While these changes may not be clinically relevant at rest, their impact needs to be determined during strenuous or prolonged dives, particularly when combined with other equipment that limits thorax excursions. Future research should explore the effects of the military 5 mm wetsuit under immersed conditions to better understand their operational impact on diver performance and safety.

Male

Optimization of a niosomal formulation for Quercetin delivery: Comparative effects on growth performance, antioxidant and immune responses, and disease resistance against Streptococcus iniae in rainbow trout (Oncorhynchus mykiss).

Quercetin (QUR) is a flavonoid with antibacterial and antioxidant properties that has been studied for its effects on fish health and the immune system. Due to the low bioavailability of QUR, the present study was primarily aimed at developing a niosomal formulation of QUR to enhance its bioavailability and therapeutic properties. The performance of niosomal QUR was then compared with that of its free form by evaluating their effects on the growth and immune system of rainbow trout, Oncorhynchus mykiss. For this purpose, an optimal QUR-containing niosome was formulated by testing different proportions of cholesterol, surfactant, and stabilizer, and the niosomes were then added to the fish diet. A QUR-free diet and a diet containing QUR-free niosomes (QFN) were considered control groups. Niosomes prepared at low hydrophilic-lipophilic balance (HLB) values showed higher QUR entrapment efficiency (QUR-EE%) (P&#x202f;<&#x202f;0.01). An increase in the molar ratio of cholesterol to surfactant significantly reduced QUR-EE% (P&#x202f;<&#x202f;0.05). A surfactant/cholesterol/stabilizer ratio of 1:1:0.1 increased QUR-EE% (P&#x202f;<&#x202f;0.05). The particle size of the niosomes was also affected by HLB and the surfactant/cholesterol/stabilizer ratio. Low HLB values resulted in smaller particle sizes (P&#x202f;<&#x202f;0.01). Furthermore, a surfactant/cholesterol/stabilizer ratio of 1:1:0.1 resulted in the smallest niosomal particle size (P&#x202f;<&#x202f;0.05). The presence of diacetyl phosphate as the stabilizer in the formulation improved the niosomal zeta potential to -40.55&#x202f;mV. The optimal niosomal formulation (HLB&#x202f;=&#x202f;6.6; surfactant/cholesterol/stabilizer ratio of 1:1:0.1) remained stable at 2&#x202f;&#xb0;C over 10 days of storage, as the niosomal QUR content and size did not show significant changes during this period (P&#x202f;>&#x202f;0.01). After preparation of the diets containing the optimal niosomal QUR, fish were fed the experimental diets for two months. QUR, in both niosomal and free forms, resulted in better growth performance than the QUR-free diets (P&#x202f;<&#x202f;0.01). There were no significant differences in growth performance between the free and niosomal forms of QUR; however, 500&#x202f;mg/kg QUR showed significantly better growth performance than 250&#x202f;mg/kg QUR (P&#x202f;<&#x202f;0.01). Although both the niosomal and free forms of QUR enhanced immune and antioxidant components in the fish, the effects of the niosomal form were more significant (P&#x202f;<&#x202f;0.01). In addition, QUR in both free and niosomal forms reduced fish mortality after challenge with Streptococcus iniae. In conclusion, the results of this study suggest that the niosomal form of QUR has strong potential for improving the immune system of fish and increasing resistance to S. iniae infection.

Animals

Effects of adjunctive bifrontal tDCS on depressive symptoms and cognitive performance in major depressive disorder: A randomized, double-blind, sham-controlled crossover pilot study.

BACKGROUND: Evidence for antidepressant effects of transcranial direct current stimulation (tDCS) in major depressive disorder (MDD) is heterogeneous, and cognitive effects remain uncertain. We compared depressive symptoms and DSST performance during active and sham bifrontal tDCS in medicated outpatients with MDD and baseline HAMD-17 &#x2265; 15. METHODS: In this randomized, double-blind, sham-controlled crossover pilot trial, adults with MDD and inadequate response to an adequate antidepressant trial were assigned to active&#x2192;sham or sham&#x2192;active tDCS sequences while continuing antidepressants. Each period comprised 10 sessions over 2 weeks. Active stimulation was delivered at 2 mA for 20 min (anode F3, cathode F4); sham used the same montage with brief ramping only. No washout interval was used. No washout interval was used. The primary outcome was HAMD-17; secondary outcomes were DSST and CGI ratings. RESULTS: Of 38 randomized participants, 32 completed both periods and were analyzed per protocol. HAMD-17 scores were lower during active than sham stimulation (mean difference -3.63, 95% CI -5.86 to -1.40; p = 0.002), but the condition-by-sequence interaction was significant (p = 0.026). No condition effect was observed for DSST (p = 0.261) or CGI-Severity (p = 1.000); CGI-Improvement was strongly sequence-dependent (p < 0.001). In an exploratory first-period analysis, adjusted T1 HAMD-17 scores were lower in the active-first group (adjusted difference -4.90, 95% CI -7.92 to -1.87; p = 0.003). Adverse effects were mild and transient. CONCLUSIONS: Active tDCS was associated with lower HAMD-17 scores, but the pooled contrast was order-dependent and cannot be interpreted as a definitive treatment effect. No DSST benefit was observed.

Humans

Effects of six weeks of guanidinoacetic acid supplementation with and without creatine monohydrate on cognitive function and markers of health in healthy adults.

BACKGROUND: Guanidinoacetic acid (GAA) supplementation has been reported to increase brain creatine content more effectively than creatine monohydrate (CrM). However, the effects on cognitive function are unclear. PURPOSE: The purpose of this proof-of-concept exploratory clinical trial was to determine whether GAA supplementation with and without CrM affects cognitive function and/or markers of health. METHODS: In a double-blind, randomized, and counterbalanced manner, 58 healthy and active adults (33 females, 35.5&#x2009;&#xb1;&#x2009;14 years, 76.2&#x2009;&#xb1;&#x2009;14 kg) ingested a PLA (PLA, 2 &#xd7; 6 g/d maltodextrin), GAA (2 &#xd7; 1 g/d)&#x2009;+&#x2009;PLA (2 &#xd7; 5 g/d), or GAA (2 &#xd7; 1 g/d)&#x2009;+&#x2009;CrM (2 &#xd7; 5 g/d) for six weeks. The participants donated fasting blood samples and completed a battery of tests and questionnaires assessing various aspects of function, mood, stress, sleep quality, and markers of health at baseline and after six weeks of supplementation. Data were analyzed using General Linear Model (GLM) multivariate and univariate with repeated measures, and mean changes from baseline with 95% confidence intervals, and Chi-squared analysis, and considered significant when the probability of error was 0.05 or less, and approaching significance (p&#x2009;>&#x2009;0.05-p&#x2009;<&#x2009;0.10). RESULTS: GAA supplementation tended to improve overall reaction time (-241.8&#x2009;ms [-533, 50], p&#x2009;=&#x2009;0.10) while significant interaction effects were observed in overall reaction time (p&#x2009;=&#x2009;0.031-330 ms [-629, -31]) and YES reaction time (-290&#x2009;ms [-484, -96], p&#x2009;=&#x2009;0.004) while recalled correct reaction time (-178&#x2009;ms [-374, 21], p&#x2009;=&#x2009;0.078) and recalled correct YES (7.4 % [-1, 15.8], p&#x2009;=&#x2009;0.084) approached significance compared to PLA. Limited to no effects were observed on the Delayed Picture Recognition Task Test, Digit Vigilance Task Test, Corsi Block Task Test, or Stroop Color-Word Task Test. The amount of time engaged in moderate physical activity was significantly greater (p&#x2009;<&#x2009;0.05) in the GAA group compared to PLA. Participants in the GAA group reported a lower frequency of controlling irritations (p&#x2009;=&#x2009;0.036), and feeling like difficulties are mounting (p&#x2009;=&#x2009;0.053) on the Perceived Stress Scale. Some positive and potentially undesirable effects were observed in sleep quality assessments. The quality of life assessment revealed that participants in the GAA group reported less frequent feelings of being worn out (p&#x2009;=&#x2009;0.068) and that their health was excellent (p&#x2009;=&#x2009;0.092) while those in the GAA&#x2009;+&#x2009;CrM group reported more frequent limitations when bending, kneeling, or stooping (p&#x2009;=&#x2009;0.053), more often feeling full of life (p&#x2009;=&#x2009;0.081), and less frequency in feeling downhearted and depressed (p&#x2009;=&#x2009;0.066). No clinically meaningful changes were observed in blood markers or self-reported side effects among the groups. CONCLUSION: Dietary supplementation with GAA (2 g/d) and the combination of CrM (10 g/d&#x2009;+&#x2009;GAA 2 g/d) for six weeks improved delayed verbal episodic recognition memory and retrieval speed and some measures of perceived stress, sleep quality, and quality of life. However, most cognitive tests were not affected, particularly when comparing the GAA to the PLA group; there were some inconsistencies in the findings, and several differences only approached significance. Additional research is needed before conclusions can be drawn. Clinical trial registration: ISRCTN68542582.

Humans