Search PubMedSearch

SEARCH · Search PubMed

Results for “surgical technique”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

391 records · Page 11Linked to original sources

Development, feasibility, acceptability, and preliminary impact of NutriSOS®: A behavioral mobile app to promote sustainable diets.

The primary objective of this study was to describe the development of the NutriSOS&#xae; app and to evaluate its feasibility and acceptability for its use in the NutriSOS&#xae; Randomized Controlled Trial (RCT) to promote sustainable diets. A secondary objective was to explore preliminary changes in dietary and physical activity behaviors and environmental impact following app use. The NutriSOS&#xae; app integrates personalized dietary advice, educational content, self-monitoring, and social interaction features. A single-arm, pre-post pilot study was conducted in 37 young Mexican adults over four weeks. Feasibility, acceptability, quality, and usability were assessed using online surveys, alongside exploratory changes in dietary and physical activity behaviors, environmental indicators, and their association with perceived behavioral determinants. Feasibility and acceptability were high overall, with favorable responses reaching up to 100% in key components such as the nutritional guide and learning modules, and above 90% for messaging, registration, and design. Greater variability was observed in some sections, particularly the 24-h recall (41-86%). Reductions in red and processed meat and ultra-processed food consumption were observed (from 3 to 1 times/week, p&#xa0;<&#xa0;0.01), with &#x223c;60% decreases in their related environmental footprints (p&#xa0;<&#xa0;0.01) and favorable self-reported behavioral determinants (p&#xa0;<&#xa0;0.0001). Physical activity type and intensity changed (p&#xa0;<&#xa0;0.05). These findings support NutriSOS&#xae; as a feasible and acceptable tool, while highlighting areas for refinement, particularly those related to the time and effort required for data entry, prior to its implementation in the NutriSOS&#xae; RCT, in which its effectiveness will be formally evaluated.

Humans

Efficacy and safety of microwave ablation for the treatment of pulmonary osteosarcoma oligometastases.

PURPOSE: Evaluate efficacy and safety of microwave ablation (MWA) for pulmonary osteosarcoma oligometastases. METHODS: Twenty-two patients (median age, 16&#x2009;years [range, 9-41&#x2009;years]; 15 male) with pulmonary osteosarcoma oligometastases who underwent MWA from January 2018 to December 2023 were included, with 27 MWA sessions for 36 lung metastases. Technical success and complications were evaluated in all 22 patients, while efficacy and survival were evaluated in 19 patients with 24 MWA sessions in treatment of 32 tumors. Technical success was assessed for each tumor. Local tumor control, progression-free survival (PFS) and overall survival (OS) were estimated using Kaplan-Meier method. Complications were classified using Common Terminology Criteria for Adverse Events version 5.0. RESULTS: Technical success was achieved in all 36 tumors (100.0%). Local tumor progression occurred in five of 32 tumors (15.6%). The estimated local tumor control rates at 12, 24 and 36&#x2009;months were 96.9%, 86.1% and 81.5%, respectively. No significant difference in local control was found between tumors &#x2264; 10&#x2009;mm and > 10&#x2009;mm (p&#x2009;=&#x2009;.470). Twelve of 19 patients (63.2%) developed new lung metastases outside the ablation area, including one with concurrent newly developed bone metastases and one with recurrence of primary osteosarcoma. The median PFS was 21.5&#x2009;months. The estimated OS rates at 12, 24 and 60&#x2009;months were 100.0%, 94.4% and 94.4%, respectively. Major complications occurred in five of 27 sessions (18.5%). CONCLUSIONS: MWA preliminarily demonstrates a high technical success rate, notable local tumor control, promising overall survival and acceptable safety for pulmonary osteosarcoma oligometastases.

Adolescent

Solutions for engaging priority populations in HIV cure research: a hybrid Delphi consensus-building process.

BACKGROUND: To achieve consensus on barriers and strategies to improve the engagement of three priority populations - Black and Latino/a/x individuals, cisgender women, and transgender women in HIV cure research. METHODS: We assembled a panel of 54 experts assigned to six groups in a hybrid Delphi process: (1) HIV community members, (2) biomedical researchers, (3) medical providers, (4) funders and private industry members, (5) bioethicists and regulators, and (6) social scientists. Over 18 months, we conducted four iterative survey rounds and three group discussions to identify barriers and strategies to arrive at a consensus on how to engage these priority populations in HIV cure research. RESULTS: For Black and Latino/a/x populations, the panellists identified inadequate outreach and a lack of accessible educational information as primary barriers and emphasised community-driven engagement and partnerships with trusted leaders as key strategies. For cisgender women, logistical hurdles, caregiving responsibilities and time constraints were identified as major barriers, with flexible trial designs and equitable compensation proposed as solutions. For transgender women, the lack of transgender-focused research design, including misrepresentation and exclusion, was identified as a key barrier, while centring transgender-specific needs in study design achieved consensus as the most effective strategy. CONCLUSION: Among all four priority populations, investment in outreach, engagement along the research process, better integration of health needs with research, and enhanced incentives are not novel ideas, but remain obviously ignored in a way that has led to underrepresentation of people in HIV cure research, who carry the greatest burden of HIV in the U.S. SUMMARY: This paper uses a hybrid Delphi process to identify and reach consensus on key barriers and strategies to engage underrepresented groups: Black and Latino/a/x individuals, cisgender women, and transgender women in HIV cure research across the United States.

Humans

Physical reconfiguration of limb electrodes for Precordial Bipolar Lead acquisition: Morphological validation against digital subtraction.

BACKGROUND: The V2&#xa0;-&#xa0;V1 Precordial Bipolar Lead (PBL) selectively evaluates the right-to-left retrosternal axis and has shown diagnostic value beyond the standard 12&#x2011;lead electrocardiogram. However, its use has been limited by the need for raw electrocardiographic data and post-processing software. This study evaluated whether a simple physical reconfiguration of limb electrodes could reproduce the digitally derived V2&#xa0;-&#xa0;V1 morphology with sufficient accuracy for clinical application. METHODS: Thirty-seven subjects underwent two sequential 10-s 12&#x2011;lead recordings using a Cardiovit FT-1 electrocardiograph sampled at 1000&#xa0;Hz. In the standard recording, the digital PBL was calculated as V2&#xa0;-&#xa0;V1. In the second recording, the right-arm and left-arm electrodes were repositioned to the V1 and V2 sites so that Lead I directly recorded the retrosternal dipole. Signals were filtered, synchronized, and analyzed using median beats. Morphological agreement was assessed with Pearson correlation on Z-normalized signals, while absolute agreement was evaluated using Lin's concordance correlation coefficient (CCC), intraclass correlation coefficient (ICC (Lewis, 1931; Nehb, 1938 [1,2])), root mean square error (RMSE), and Bland-Altman analysis. RESULTS: Mean Pearson correlation between digital and physical PBL was 0.955 (SD 0.043), with segment-specific correlations of 0.953 (SD 0.054) for QRS and 0.967 (SD 0.052) for ST-T. Lin's CCC and ICC(2,1) were both 0.871 (SD 0.110), and RMSE was 0.091 (SD 0.049) mV. Bland-Altman analysis showed minimal bias (-0.008&#xa0;mV). CONCLUSIONS: Physical acquisition of the V2&#xa0;-&#xa0;V1 PBL achieved high agreement with the digitally derived signal, supporting a simplified analog method for broader clinical implementation.

Humans

Marginal fit and five-year outcomes of posterior monolithic zirconia restorations: A randomized paired and observational clinical study.

OBJECTIVES: The aim of this study was to evaluate the marginal fit and five-year clinical performance of posterior 5 mol% yttria-partially stabilized zirconia restorations. A randomized paired comparison with lithium disilicate crowns was performed for marginal fit. METHODS: A total of 65 posterior restorations were placed in 38 patients, including 32 zirconia crowns, 17 lithium disilicate crowns, and 16 zirconia partial coverage restorations. In the randomized paired comparison, 17 patients received one lithium disilicate crown and one zirconia crown. Additional zirconia crowns (n=15) and zirconia partial coverage restorations (n=16) were included in a prospective observational cohort. The primary outcome was marginal fit within the randomized cohort. Marginal and internal fit were assessed using the replica technique. Marginal and internal gap values were compared using the Wilcoxon signed-rank test; clinical outcomes were analyzed descriptively, and Kaplan-Meier estimates were calculated for survival and complication-free survival. Clinical performance was assessed using CDA criteria, periodontal parameters, complication recording, and patient-reported outcomes. Clinical examinations were performed at baseline and at 12, 24, 36, 48, and 60 months. RESULTS: Mean marginal gap values at the crown margin were 46 &#xb1;33 &#xb5;m for lithium disilicate crowns and 50 &#xb1;32 &#xb5;m for zirconia crowns (p>0.05). No restoration required replacement, resulting in 100% restoration survival after a median follow-up of 60 months (range: 57-64 months). Most complications were biological or functional, including endodontic, periodontal, occlusal, and proximal-contact-related events. One zirconia partial coverage restoration exhibited a small ceramic fracture managed by polishing. The Kaplan-Meier probability of complication-free survival was 76.4% for zirconia crowns, 66.7% for lithium disilicate crowns, and 87.5% for zirconia partial coverage restorations. CONCLUSIONS: In the randomized paired comparison, 5 mol% yttria-partially stabilized zirconia crowns showed marginal gap values similar to lithium disilicate crowns. All restorations remained in situ during the observation period. Lower complication-free survival was mainly related to biological and functional events and should be interpreted separately from restoration survival. CLINICAL SIGNIFICANCE: Clinical evidence for posterior 5 mol% yttria-partially stabilized zirconia restorations remains limited. This study provides mid-term clinical data on crowns and partial coverage restorations. In the randomized full-crown comparison, marginal fit was similar to that of lithium disilicate crowns, supporting the clinical consideration of monolithic zirconia restorations for posterior teeth.

Humans

Robotic surgery for gastric gastrointestinal stromal tumors: a systematic review.

Robotic surgery is used for selected gastric gastrointestinal stromal tumours (GISTs), particularly when location makes conventional wedge resection difficult. We synthesised technical, perioperative, pathological, functional and oncological outcomes. PubMed/MEDLINE, Scopus and the Cochrane Library were searched from inception to 14 August 2026. Primary reports with at least three eligible robotic gastric-GIST patients were included. Two reviewers independently selected studies, extracted data and completed design-specific JBI appraisal. Because outcome definitions, denominators and reporting were heterogeneous, findings were synthesised narratively in accordance with SWiM guidance rather than pooled. Twenty-three studies, including six comparative cohorts, were included. Institutional robotic cohorts contained 3-45 eligible patients; one national registry included 1,567 robotic cases. Tumour size ranged from 2.68&#x2009;&#xb1;&#x2009;1.55 to 7.9&#x2009;&#xb1;&#x2009;1.8&#xa0;cm among studies reporting means. Most institutional reports described R0 resection in all eligible patients; exceptions were 23/24 and 24/25, while the registry reported 1,425/1,567 R0 resections. Grade III morbidity occurred in 2/25 patients in one function-preserving series. Registry 30- and 90-day mortality after robotic resection were 0.5% and 0.8%, respectively. Comparative studies did not demonstrate superior postoperative or oncological outcomes with robotic surgery. Robotic gastric-GIST resection appears feasible in selected patients and may facilitate organ-preserving surgery at anatomically challenging sites. Current observational evidence does not establish comparative functional, oncological or economic superiority.

Humans

Effect of knee and hip joint positions on passive stiffness of the rectus femoris and vastus lateralis in healthy individuals.

Passive muscle stiffness is a key determinant of musculoskeletal function and is influenced by structural components such as titin, connective tissue, and fascia. However, the effects of joint position, muscle depth, and sex on quadriceps passive stiffness remain unclear. To investigate the passive stiffness of the rectus femoris (RF) and vastus lateralis (VL) under different joint configurations, muscle depths, and between sexes using shear wave elastography (SWE). Thirty-six healthy young adults (18 men and 18 women) participated in this randomized crossover study. Passive stiffness was assessed in four positions of knee flexion: supine with 60&#xb0; (SUP60), supine with 20&#xb0; (SUP20), sitting with 60&#xb0; (SIT60), and sitting with 20&#xb0; (SIT20). SWE measurements (m/s) were obtained from 30 regions of interest (ROIs) per muscle, categorized into superficial, intermediate, and deep levels. Data were analyzed using Generalized Estimating Equations (GEE). A significant effect of position was observed, with higher stiffness values in the SUP60 condition for both RF and VL (p&#x2009;<&#x2009;0.001). Superficial regions consistently exhibited greater stiffness compared to intermediate and deep regions across all positions (p&#x2009;<&#x2009;0.001). Additionally, men demonstrated significantly higher stiffness values than women (p&#x2009;<&#x2009;0.001). Significant interactions were found between position and muscle, as well as position and depth. Quadriceps passive stiffness is influenced by joint position, muscle depth, and sex. The SUP60 position elicits the highest stiffness, while superficial muscle regions are consistently stiffer. These findings highlight the non-uniform mechanical behavior of the quadriceps and may have implications for clinical assessment, rehabilitation, and exercise prescription. Clinical trial registration: This study was registered at Clinicaltrials.gov in June 06th, 2023. Register number NCT05905406. Link to access https//clinicaltrials.gov/study/NCT05905406.

Humans

Autologous Fibrin Glue in Pterygium Surgery as an Alternative to Commercial Fibrin Glue.

PURPOSE: The aim of this study was to evaluate the efficacy and safety of autologous fibrin glue in pterygium surgery, comparing it with commercial fibrin glue in terms of postoperative complications, graft stability, and recurrence rate. METHODS: A prospective, randomized, double-blind study was conducted, involving 42 patients with primary pterygium who underwent autologous conjunctival-limbal transplantation. The graft was fixed using autologous fibrin glue (Group 1, G1) or commercial fibrin glue (Group 2, G2). All patients underwent surgery performed by the same surgeon and were reevaluated on postoperative days 7, 30, 90, and 180 by an independent observer, assessing clinical parameters in the preoperative, intraoperative, and postoperative periods. RESULTS: No cases of severe adverse events were reported. Complete graft dehiscence occurred in 1 patient from G1. The G2 group had more cases of subconjunctival hemorrhage ( P = 0.0355). Pyogenic granuloma was observed in 1 patient from G2 and 2 patients from G1. There was no significant difference in recurrence rates between the groups (15% in G1 vs. 5% in G2; P = 0.2918). In both groups, graft dimensions tended to decrease slightly in the early postoperative period, followed by stabilization. CONCLUSIONS: Autologous fibrin glue demonstrated efficacy and safety comparable to commercial fibrin glue, making it a viable alternative to conjunctival graft fixation in primary pterygium surgery.

Humans

Beyond da Vinci: a systematic review of next-generation multiport robotic platforms in pediatric surgery.

As robotic surgery expands beyond the da Vinci platform, the relevance of new-generation systems to pediatric patients remains uncertain. This review examined the technical characteristics, applications, and perioperative outcomes of alternative multiport robotic platforms in children. PubMed/MEDLINE, Web of Science, Scopus, and the Cochrane Library were searched through 28 February 2026 in accordance with PRISMA 2020. Owing to clinical heterogeneity, findings were synthesized narratively, with Wilson 95% confidence intervals for key binary outcomes. Six studies reported 166 patients across 27 procedure types. Senhance accounted for 164 patients, while Hugo RAS and Hinotori were each represented by one patient. Ages ranged from 15&#xa0;days to 17&#xa0;years and weights from 3.8 to more than 100&#xa0;kg. Senhance was the only platform used with 3-mm robotic instruments. Conversion or planned escalation occurred in 19 patients (11.4%; 95% CI, 7.5-17.2%). Four intraoperative complications were reported (2.4%; 95% CI, 0.9-6.0%). Across all reports, 20 patients experienced postoperative complications (12.0%; 95% CI, 7.9-17.9%). In the largest cohort, seven patients required reintervention (4.6%; 95% CI, 2.2-9.2%) and seven were readmitted (4.6%; 95% CI, 2.2-9.2%). No deaths or comparative pediatric studies were reported. Published experience remains sparse and is almost entirely limited to Senhance. Current evidence describes early clinical use without establishing comparative safety, effectiveness, or platform superiority. Prospective multicenter studies with standardized reporting are needed.

Humans

Construction of precision clinical-proteomics risk model based on machine learning for predicting heart failure in type II diabetes mellitus.

BACKGROUND AND AIMS: Heart failure (HF) is a severe complication in type 2 diabetes mellitus (T2DM), but current risk stratification scores have limited predictive accuracy. We aimed to develop novel prediction tools integrating clinical variables with proteomics to improve risk stratification of hospitalization for HF in T2DM. METHODS AND RESULTS: In this study, we included 2111 UK Biobank participants with T2DM but no prior HF, and profiled 2920 proteins to predict 10-year incident HF hospitalization. Participants were randomly divided into training (70%), tuning (10%), and validation (20%) sets.Three prediction models were developed: a Clinical model based on demographic characteristics, comorbidities, medication use, and laboratory indices; a Protein model based on 40 proteins selected by the Light Gradient Boosting Machine (LGBM); and the Clinical OMics and Protein ASSessment for Heart Failure (COMPASS-HF) model, which integrated both clinical variables and the LGBM-selected proteins. Models were evaluated for area under the curve (AUC), sensitivity, and specificity. During follow-up, 168 participants (7.96%) developed incident HF. The COMPASS-HF model showed better discrimination than the Clinical model, with an AUC of 0.897 (95% CI: 0.850-0.945) versus 0.790 (95% CI: 0.723-0.856). It also demonstrated higher sensitivity (0.882; 95% CI: 0.725-0.967) and consistent performance in subgroups. COMPASS-HF effectively stratified risk of hospitalization for HF, with cumulative incidence rates of 31.9% in the high-risk group and 1.2% in the low-risk group. CONCLUSIONS: By combining clinical and proteomic variables, we developed a high-performance HF prediction model for T2DM, enabling precise risk stratification and informing early intervention strategies.

Humans

Data-centric, robust, and explainable multimodal deep learning for clinical decision support: A systematic review.

PURPOSE: Multimodal deep learning is increasingly proposed for clinical decision support (CDS) under a "data-centric" framing that prioritizes label quality, missing-modality robustness, distribution shift, calibration, and explainability. Prior reviews have examined multimodal medical AI, CDS, and data-centric methods separately, but none address their intersection. We mapped the modalities, fusion strategies, and data-centric and explainability techniques used in this recent literature, quantified how often each is implemented rather than merely mentioned, assessed deployment-relevant evidence (external validation, clinical-outcome measurement, equity), and formally appraised study-level risk of bias. METHODS: Following the PRISMA 2020 statement (PROSPERO CRD420261427815; registered retrospectively), we screened 150 records and included primary, clinical, multimodal studies that applied machine or deep learning to a decision-support task and reported at least one quantitative result. Two reviewers screened and extracted data with consensus adjudication. Each study was coded against pre-specified operational definitions, separating implemented or empirically evaluated techniques from those only mentioned. Study-level risk of bias was assessed with PROBAST + AI. Synthesis was narrative. RESULTS: Thirty-one studies met inclusion; 30 (97%) were published between 2024 and 2026, with a median of three modalities (range 2-6), most commonly structured EHR (71%) and imaging (39%). Data-centric techniques were frequently reported (74-84% across label-noise, distribution-shift, calibration, missing-modality and class-imbalance handling; equity 61%). However, external validation was reported in only 4/31 studies (13%), a clinical or provider outcome in 3/31 (10%), and no study reported routine deployment. Overall risk of bias was high in 27/31 studies (87%), driven by the analysis domain. CONCLUSION: Within this recent, self-selected slice of the field, technical robustness and explainability techniques are widely reported but rarely validated out-of-distribution or against clinical outcomes, and the underlying evidence is at high risk of bias. Progress requires external multi-site validation, clinical-outcome measurement, formal bias appraisal, and adherence to AI reporting standards (e.g., TRIPOD + AI) before deployment can be justified.

Deep Learning

Pulmonary artery catheters or central venous catheters for cardiac surgery: the PUMA Pilot randomised clinical trial.

INTRODUCTION: Pulmonary artery catheters are used widely in cardiac surgery despite observed associations with worse outcomes and guidelines that recommend against their routine use. No adequately powered randomised trials are available. METHODS: The PUMA Pilot was a multicentre, randomised, parallel assignment, open-label, pilot and feasibility trial conducted at three tertiary cardiac surgery centres. Eligible patients were adults undergoing coronary artery bypass grafting, aortic valve replacement or surgery on the aortic root or ascending aorta with or without aortic valve replacement, with a predicted surgical mortality of <&#x2009;2%. Patients were allocated randomly to receive a pulmonary artery catheter or a central venous catheter inserted immediately before surgery. The primary feasibility outcome was protocol compliance, defined as receiving the assigned intervention without crossover. Secondary feasibility outcomes were eligibility rate; recruitment proportion and rate; data completeness; and rate of clinician refusal. RESULTS: We screened 480 patients and 206 (43%) were eligible; 150/203 (74%) approached provided informed consent. Three of 206 (1%) eligible patients were not included due to clinician refusal. Of 149 patients who were randomised, 76 were assigned to the pulmonary artery catheter group and 73 to the central venous catheter group. For the primary feasibility outcome, 147 patients (99%) received the allocated intervention. Data were complete for 144 (97%) patients. Median (IQR [range]) days alive and at home at 30&#x2009;days was 23.7 (21.9-24.7 [7.0-26.0]) in the pulmonary artery catheter group and 22.9 (20.8-23.9 [8.6-25.8]) in the central venous catheter group. Acute kidney injury occurred in 26/76 (34%) patients in the pulmonary artery catheter group and 14/73 (19%) in the central venous catheter group. DISCUSSION: A randomised trial of pulmonary artery catheters compared with central venous catheters in low-risk cardiac surgery is feasible. Such a trial would address significant practice variability and inform international guidelines.

Humans

Contrast Heat-Cold Versus Thermoneutral Showering in Trained Combat Sport Athletes: A Randomized Field Trial of Recovery Outcomes.

Contrast heat-cold showering is popular for recovery, but multisystem evidence and persistence after cessation remain unclear. To evaluate whether a 4-week post-training contrast heat-cold shower intervention produces an integrated recovery profile across four domains (autonomic, endocrine, perceptual, and microvascular) rather than testing a single isolated physiological pathway, across baseline (T0), post-intervention (T1), and 2-week wash-out (T2). Sixty combat-sport athletes were randomized to contrast showers (10 min alternating warm 38-40&#xb0;C and cold 13-15&#xb0;C) or an active thermoneutral-shower comparator (10 min, 32-34&#xb0;C) after training for 4 weeks. Primary analyses were per-protocol (&#x2265; 75% compliance; n = 57), with intention-to-treat sensitivity analyses. Outcomes were Total Quality Recovery (TQR), morning salivary cortisol (two mornings averaged), resting HRV, and post-occlusive reactive hyperemia (PORH). From T0 to T1, favorable between-group changes were observed for resting HR (&#x394;&#x394; -2.10 bpm, 95% CI -2.24 to -1.96; g -0.65; p < 0.001), lnRMSSD (&#x394;&#x394; 0.123 log units, 95% CI 0.108 to 0.137; g 0.74; p < 0.001), with similar T1 effects for RMSSD and SDNN, and TQR (&#x394;&#x394; 0.61 points, 95% CI 0.27 to 0.95; g 0.80; p < 0.001). These T1 autonomic and perceptual changes were not maintained at T2 (all T2-T0 &#x394;&#x394; p > 0.05). Cortisol and PORH-derived outcomes showed no statistically clear between-group differences at T1 or T2 (all p > 0.05). Compared with thermoneutral showering, 4 weeks of post-training contrast heat-cold showering produced short-term favorable between-group changes in autonomic regulation and perceived recovery, but not in morning cortisol or PORH-derived microvascular reactivity. These effects were not maintained after wash-out; therefore, causal attribution to the shower intervention alone and claims of persistent physiological adaptation should be made cautiously. Trial registration: ISRCTN15418049.

Humans

Diagnostic performance of panfungal PCR on tissue specimens for the diagnosis of invasive fungal diseases: a systematic review and meta-analysis of the Fungal PCR Initiative (FPCRI).

UNLABELLED: Invasive fungal diseases are difficult to diagnose because of the limited sensitivity of culture. Panfungal PCR amplicon sequencing assays (targeting ribosomal RNA, such as 18S, 28S, ITS) are recommended for fungal identification in histopathology samples showing fungal elements. However, data describing its overall performance and consistency are lacking. This systematic literature review and meta-analysis assessed the performance of panfungal PCR on formalin-fixed paraffin-embedded (FFPE) and non-fixed (fresh or frozen) tissue samples. A systematic literature search was performed to include studies reporting the use of panfungal PCR for fungal identification in FFPE or non-fixed tissue samples. PCR sensitivity and specificity were assessed using the reference standard of histopathology showing fungal elements. Quality assessment was performed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Pooled estimates were obtained using random-effects meta-analysis. Twenty-eight studies were included. In FFPE samples (18 studies, 852 samples), sensitivity and specificity were 75.4% (95% confidence interval [CI], 59.2-86.6) and 93.5% (70.2-98.9), respectively. Sensitivity in non-fixed samples (13 studies, 207 samples) was 86.5% (74.7-93.3), while specificity could not be assessed (insufficient data). Comparative analyses showed a significantly higher sensitivity of panfungal PCR over culture (88.2%; 76-94.7 vs 52.2%; 39-65, P = 0.001). Sub-analyses could not demonstrate the superiority of one PCR target over another due to limited data. Panfungal PCR exhibited adequate sensitivity and good specificity in FFPE samples. Sensitivity was even higher in non-fixed samples and largely superior to culture. Nevertheless, large interstudy variability was observed, warranting interlaboratory studies to define the optimal PCR target and standardized protocols. IMPORTANCE: Invasive fungal diseases are difficult to diagnose because of the low sensitivity of culture. Panfungal PCRs are widely used for fungal identification in tissue specimens but suffer from heterogeneous procedures and performance. This meta-analysis shows an acceptable sensitivity (75.4% and 86.5% in fixed and non-fixed samples, respectively) and good specificity (93.5%) of panfungal PCR, supporting its use, not only on histopathology-positive fixed samples but also in non-fixed samples concomitantly with other diagnostic tools (cultures and fungal-specific PCRs if available). These results provide a strong basis for further standardization of panfungal PCR techniques via interlaboratory assays to assess reproducibility and optimize analytical protocols. CLINICAL TRIALS: This study is registered with PROSPERO as CRD42023461148.

Humans

A New Highly Concentrated Insulin Aspart AT278 (500&#x2009;U/mL) Demonstrates Ultra-Rapid Pharmacokinetic and Pharmacodynamic Properties in Type 2 Diabetes Regardless of BMI.

AIMS: To evaluate the pharmacokinetics, pharmacodynamics, and safety of a novel U500 insulin aspart formulation (AT278 [500&#x2009;U/mL]; AT278-U500) compared with standard concentration insulin aspart (InsAsp [100&#x2009;U/mL]; InsAsp-U100) and U500 human regular insulin (HumIns [500&#x2009;IU/mL]; HumIns-U500). MATERIALS AND METHODS: This single-centre, randomised, double-blind crossover 12-h euglycaemic clamp study was conducted in 41 overweight and obese people with type 2 diabetes (BMI 25.0-38.7&#x2009;kg/m2) receiving a single subcutaneous dose (0.5&#x2009;U/kg) of AT278-U500 and InsAsp-U100. HumIns-U500 was consecutively studied open label in a 24-h clamp. RESULTS: AT278-U500 exhibited a significantly faster insulin absorption than InsAsp-U100 and HumIns-U500 (t Early50%Cmax: 9&#x2009;min vs. 35&#x2009;min vs. 55&#x2009;min), leading to a significantly higher glucose-lowering effect within the first hour (AUCGIR,0-60min) compared with both InsAsp-U100 (treatment ratio 2.02 [95% CI 1.64; 2.50]) and HumIns-U500 (3.91 [2.89; 5.27]). When divided by median BMI (29.7&#x2009;kg/m2), AUCGIR,0-60min was significantly higher with AT278-U500 in both the low-BMI and high-BMI subgroup compared to InsAsp-U100. Linear regression showed a significant inverse relationship between BMI and AUCGIR,0-60min for InsAsp-U100 (slope -0.142, p&#x2009;<&#x2009;0.0001), whereas AT278-U500 showed no such relationship. Overall insulin exposure was similar for AT278-U500 and InsAsp-U100, while overall glucose-lowering effect was comparable across all three treatments. CONCLUSIONS: AT278-U500 maintains its ultra-rapid onset characteristics independent of BMI, representing the first ultra-rapid U500 option for prandial dosing in insulin-resistant people with type 2 diabetes requiring high-dose therapy. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT05754424.

Humans

A 20-Y Analysis of Motorcycle Trauma After Helmet Law Repeal.

INTRODUCTION: After Arkansas repealed its universal motorcycle helmet law in 1997, helmet use decreased and motorcycle-related injuries and fatalities increased. Long-term clinical and population-level impacts of this policy change remain incompletely characterized. This study integrates statewide crash and fatality data with trauma center data to evaluate trends in helmet use, injury severity, and mortality at scene and hospitalization. METHODS: We retrospectively reviewed motorcycle-related admissions and emergency department deaths at the state's only adult level I trauma center from 2004 to 2023 across three periods: 2004-2006, 2013-2015, and 2021-2023. Demographics, helmet use, injury severity, and outcomes were assessed. Logistic regression evaluated associations between helmet use, severe head injury (Abbreviated Injury Scale &#x2265;3), and inhospital mortality. Fatality data were obtained from the National Highway Traffic Safety Administration, and crash-level data (2015-2023) were obtained from the State Department of Transportation. RESULTS: Among 1104 trauma admissions, annual admissions nearly tripled over time, with nonhelmeted riders representing 64%-72%. Helmet use was independently associated with lower odds of severe head injury (odds ratio 0.48, P < 0.001). Nonhelmeted riders had higher on-scene fatality risk (relative risk 1.21). Severe head injuries increased and were strong predictors of inhospital mortality. Population-adjusted motorcycle fatality rates rose from 2.34 to 3.18 per 100,000 residents by 2021-2023. CONCLUSIONS: Motorcycle fatalities and severe head injuries increased during the postrepeal period and were associated with helmet nonuse and severe head trauma. Clinical and statewide data show consistent associations among helmet nonuse, severe head injury, and prehospital and in-hospital mortality, highlighting helmet use as a target for injury prevention policy.

Acute brain injury

Effects of essential amino acid supplementation on musculotendinous recovery following eccentric plantar flexor exercise: a randomized controlled trial.

BACKGROUND: Exercise-induced muscle damage (EIMD) resulting from eccentric contractions leads to transient impairments in muscle function. Essential amino acids (EAAs) stimulate muscle protein synthesis and may support recovery following damaging exercise. However, limited research has examined the effects of EAAs on muscle function following eccentric plantar flexor exercise. The purpose of this study was to examine the effects of EAA supplementation on indirect markers of muscle and musculotendinous recovery following EIMD. METHODS: Thirty-six recreationally active males (age: 21.2&#x2009;&#xb1;&#x2009;2.7&#x2009;years) were randomly assigned to an EAA group (10&#x2009;g of EAAs), placebo (10&#x2009;g of maltodextrin), or control (no supplementation). Supplements were consumed 30&#x2009;minutes before and immediately after an eccentric plantar flexor protocol (4&#x2009;&#xd7;&#x2009;50 repetitions followed by one set to failure) and during the 72&#x2009;hours recovery period. Indirect markers of muscle damage were assessed pre-exercise, immediately post-exercise, and 24, 48, and 72&#x2009;hours post-exercise, consisting of perceived soreness (NPRS), pain pressure threshold (PPT), calf muscle thickness and Achilles tendon thickness (ultrasound), and calf circumference. RESULTS: The eccentric protocol elicited responses consistent with EIMD, including increased soreness (p&#x2009;<&#x2009;0.001), increased calf muscle thickness and circumference (p&#x2009;<&#x2009;0.001), and reduced PPT (p&#x2009;=&#x2009;0.018). EAA supplementation attenuated soreness at 24&#x2009;hours compared with placebo. Calf muscle thickness increased following exercise in both groups; however, swelling returned to baseline by 72&#x2009;hours in the EAA group but remained elevated in placebo (Condition&#x2009;&#xd7;&#x2009;Time, p&#x2009;<&#x2009;0.001). Achilles tendon thickness decreased immediately post-exercise (p&#x2009;=&#x2009;0.005) but was not influenced by supplementation. CONCLUSIONS: EAA supplementation modestly reduced soreness and was associated with faster recovery of muscle swelling but did not influence tendon morphology within 72&#x2009;hours.

Humans

Comfort and Usability of Digital Versus Conventional Custom-Fit Mouthguards: A Randomized Clinical Trial.

BACKGROUND/OBJECTIVES: The use of mouthguards protects teeth and the supporting tissues against impacts. Digital impressions and 3D-printed models can reduce manufacturing steps and minimize discomfort. This study evaluated the fit, comfort, and usability of custom-made mouthguards, obtained by conventional and digital workflow, in amateur athletes. MATERIALS AND METHODS: Amateur athletes were recruited for this randomized, double-blind, crossover clinical study. Each participant received two 4-mm-thick custom-fit mouthguards made of ethylene vinyl acetate (EVA) sheets using two protocols: conventional impression using alginate to produce dental stone cast (CMP) and intraoral digital scanning to produce 3D-printed resin models (DMP). Each mouthguard was worn during all training and matches over 3&#x2009;months. The order of mouthguard use was randomly assigned. Patient satisfaction with the impression protocol and mouthguard use, model accuracy, and mouthguard fit were assessed. RESULTS: Overall, 46 participants completed the study. The DMP protocol required less execution time (p&#x2009;=&#x2009;0.023), caused less discomfort (p&#x2009;=&#x2009;0.018), anxiety (p&#x2009;=&#x2009;0.008), nausea (p&#x2009;=&#x2009;0.027), difficulty breathing (p&#x2009;<&#x2009;0.001), and unpleasant taste (p&#x2009;=&#x2009;0.006) compared to the CMP protocol. The pain (p&#x2009;=&#x2009;0.971) perceived by the participants was similar in both impression protocols. The CMP-mouthguards were considered to be better fitting by the majority of participants (p&#x2009;=&#x2009;0.027). Between-group comparisons revealed that DMP-mouthguard caused less discomfort immediately postadaptation (p&#x2009;=&#x2009;0.034), with no significant differences observed at 30 or 90&#x2009;days. CONCLUSIONS: The digital workflow demonstrated to be efficient in the fabrication of mouthguards. Digital impression was more comfortable, requiring less execution time, with more accurate printed models and produced mouthguards with reported comfort and fit levels similar to those manufactured conventionally.

Humans