Search PubMedSearch

SEARCH · Search PubMed

Results for “laser fluorescence”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

55 recordsLinked to original sources

Effect of Various Types of Remineralizing Agents on the Remineralization of Mild and Moderate Defects Caused by Molar-Incisor Hypomineralization in Mexican Schoolchildren: A 12-month Follow-up Randomized Clinical Trial.

PURPOSE: Using Laser-Induced Fluorescence (LIF), this study aimed to evaluate the effect of three remineralizing agents on permanent molars and incisors with both mild and moderate Molar-Incisor Hypomineralization (MIH) in 8-to-12-year-old Mexican schoolchildren. MATERIALS AND METHODS: In this randomized clinical trial, 104 children were selected to participate and then divided randomly into four groups: Group I: control, Oral-B kids (toothpaste); Group II: Fluor Protector (varnish); Group III: Clinpro White Varnish; and Group IV: MI Paste (CCP-ACP). Both varnishes were applied once every four weeks for twelve months for each group. Remineralization was evaluated by LIF at intervals of 1, 3, 6, 9, and 12 months. Paired-sample t-tests and repeated-measures ANOVA were performed, while the Greenhouse-Geisser correction was used to evaluate sphericity. RESULTS: The three test agents used increased the level of remineralization observed at the site of mild and moderate MIH defects over the course of twelve months (p0.001). A similar decrease in average LIF values was observed across the three treatment groups. CONCLUSIONS: The use of both fluoride varnishes and the CPP-ACP toothpaste was observed to promote the remineralization of both mild and moderate MIH defects.

Humans

Non-destructive prediction of lead content in oilseed rape leaves by fluorescence hyperspectral technology based on neural network.

Based on fluorescence hyperspectral imaging (FHSI), this study targeted rapid, non-destructive quantification of lead (Pb) content in oilseed rape leaves treated with varying silicon (Si) concentrations, acquiring fluorescence spectra over the 484.43-1001.61 nm wavelength range. To optimize spectral data quality, preprocessing methods (Savitzky-Golay smoothing, first derivative, detrending) were comprehensively compared. Characteristic wavelengths were then selected via interval variable iterative shrinkage, which effectively compressed data dimensionality and reduced computational load. A hybrid SE-CL1DA model, fusing a 1D convolutional neural network, a long short-term memory network and SE attention mechanism was constructed, with Bayesian optimization tuning hyperparameters to boost stability. The BO-SE-CL1DA outperformed both traditional machine learning and insufficiently optimized deep learning model (Rp2=0.9609, RMSE = 0.0377 mg/kg, RPD = 5.1736), thus enabling accurate Pb estimation, supporting Si-regulated heavy metal stress management and facilitating agricultural contamination monitoring.

Plant Leaves

Comparison of a 755-nm picosecond laser and a 1565-nm nonablative fractional laser for the treatment of atrophic acne scars: a 20-week prospective, randomized, split-face clinical study.

To compare the efficacy and safety of a 755-nm picosecond laser with a diffractive lens array (P-DLA) and a 1565-nm nonablative fractional laser (NAFL) for the treatment of atrophic acne scars. Twenty-seven patients with atrophic acne scars underwent three sessions of randomized split-face treatment with P-DLA and NAFL at 4-week intervals. Patients were followed up at 1, 2, and 3 months after the final treatment. Efficacy was assessed using the &#xc9;chelle d'&#xc9;valuation Clinique des Cicatrices d'Acn&#xe9; (ECCA) grading scale, the Investigator's Global Assessment (IGA) score, patients' self-rated improvement, and overall satisfaction. Treatment-related adverse reactions were recorded daily by patients until resolution. Both modalities demonstrated significant improvements in scar appearance based on ECCA score, IGA score, and patients' self-rated improvement (P&#x2009;<&#x2009;0.001). No statistically significant differences in efficacy were observed between the two treatments. However, the P-DLA group showed higher patient satisfaction (P&#x2009;=&#x2009;0.035) and a more favorable safety profile, including shorter durations of erythema and edema and the absence of crusting. Both P-DLA and NAFL were effective and safe for the treatment of atrophic acne scars, with similar efficacy. P-DLA offered better tolerability.

Humans

Effectiveness of high-power laser use in the removal of esthetic restorations: a systematic review.

This systematic review aimed to evaluate the effectiveness of high-power lasers in the removal of esthetic restorations compared with conventional methods. The review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) and registered in PROSPERO (registration number: CRD420251055736). A comprehensive electronic search was performed in MEDLINE, Scopus, Embase, Web of Science, and the Cochrane Library. Study selection, data extraction, and methodological quality assessment were independently performed by four reviewers using QUIN tool for in vitro studies. A total of 2.384 records were identified, of which 19 in vitro studies conducted on extracted human permanent teeth met the eligibility criteria and were included in the qualitative synthesis. The included studies evaluated different high-power laser systems, predominantly Er: YAG and Er, Cr: YSGG lasers, as well as CO&#x2082; lasers. Five studies were classified as high quality, whereas the remaining fourteen studies were classified as moderate quality. Available laboratory evidence suggests that laser-assisted techniques may represent a potential alternative approach for removing esthetic restorations, with advantages including conservative tissue removal, reduced damage to underlying tooth structures, and intrapulpal temperature increases within acceptable limits. The Er: YAG laser was the most frequently investigated system, with power settings ranging from 1.5 to 5.9&#xa0;W, showing particularly favorable laboratorial performance in the removal of lithium disilicate restorations, especially in thinner substrates. Within the limitations of the available evidence, high-power lasers appear to be a promising and minimally invasive alternative to conventional methods for the removal of esthetic restorations. However, the predominance of in vitro studies highlights the need for well-designed clinical trials to confirm these findings and support their clinical application.

Humans

Use of indocyanine green fluorescence versus patent blue V dye for sentinel lymph node biopsy in early breast cancer, a randomized controlled trial.

BACKGROUND: Sentinel lymph node biopsy (SLNB) is standard for axillary staging in early breast cancer. While the combination of radioisotope and blue dye (e.g., patent blue V, PBV) remains the standard, it has limitations including logistics, variable identification rate (IR), and allergic potential. Indocyanine green (ICG) fluorescence is a promising alternative, but high-quality comparative evidence is needed. METHODS: This was a single-center, prospective, randomized controlled trial. Forty patients with early-stage, node-negative breast cancer were allocated to SLNB using either ICG (n&#x2009;=&#x2009;20) or PBV (n&#x2009;=&#x2009;20). All patients subsequently underwent completion level I-II axillary lymph node dissection (ALND) as the pathological reference standard for diagnostic performance assessment. Primary outcome was sentinel lymph node (SLN) IR. Secondary outcomes included detection time, number of SLNs retrieved, false-negative rate (FNR), and safety. RESULTS: Baseline characteristics were comparable between groups. The SLN IR was significantly higher with ICG (100% [20/20]) than with PBV (75% [15/20], p&#x2009;=&#x2009;0.047). ICG was associated with a significantly shorter median detection time (14.5 vs. 24.0&#xa0;min, p&#x2009;<&#x2009;0.001) and retrieved more SLNs (mean: 3.6 vs. 2.4, p&#x2009;=&#x2009;0.002). Most critically, ICG demonstrated 100% sensitivity, specificity, negative predictive value (NPV), and overall diagnostic accuracy, with a 0% FNR. In contrast, PBV achieved a sensitivity of 75%, an overall diagnostic accuracy of 90%, and an FNR of 25%. No ICG-related adverse events occurred. PBV caused skin discoloration in 75% of patients and one (5%) allergic reaction. CONCLUSION: ICG fluorescence achieved a higher SLN IR, shorter detection time, higher sensitivity, lower FNR, and fewer tracer-related adverse events than PBV as a single tracer for SLNB in patients with early-stage breast cancer. These findings suggest that ICG is a promising standalone tracer when radioisotope mapping is unavailable. Larger multicenter studies are required before widespread adoption can be recommended.

Humans

Efficacy and safety of thulium fiber laser versus conventional holmium:YAG laser in anatomical endoscopic enucleation of the prostate: a systematic review and pairwise meta-analysis.

PURPOSE: Anatomical endoscopic enucleation is an established treatment for benign prostatic obstruction. Whether thulium fiber laser enucleation (ThuFLEP) improves outcomes over conventional holmium:YAG laser enucleation (HoLEP) remains uncertain. We compared the efficacy and safety of ThuFLEP versus non-MOSES-modulated HoLEP. METHODS: We performed a PRISMA-compliant systematic review and pairwise meta-analysis of randomised and comparative cohort studies comparing ThuFLEP and conventional HoLEP in adult men. Six databases were searched. Outcomes included International Prostate Symptom Score (IPSS), IPSS quality-of-life score, maximum urinary flow rate (Qmax), post-void residual volume, hospital stay, and complications. Risk of bias and certainty of evidence were assessed with RoB 2/ROBINS-I and GRADE. RESULTS: Seven non-overlapping comparative populations in eight publications included 3,509 patients. ThuFLEP was associated with a small statistically significant reduction in IPSS at 3&#xa0;months (mean difference [MD] -1.04 points, 95% confidence interval [CI] -1.81 to -0.28) of uncertain clinical relevance. Qmax differences were small and directionally inconsistent across follow-up (favouring HoLEP at 3&#xa0;months and ThuFLEP at 6 and 12&#xa0;months) and derived mainly from retrospective cohorts, with neutral randomised subgroups. Stress and urge urinary incontinence were less frequent overall (RR 0.75, 95% CI 0.58 to 0.96, and RR 0.39, 95% CI 0.22 to 0.68), but both estimates depended on one large registry cohort and were not robust to its exclusion. Most other complications and hospital stay showed no clear between-group difference. Limitations include few studies per outcome, heterogeneity, sparse safety events, inconsistent prostate-specific antigen reporting, and mostly low/very low certainty evidence. CONCLUSION: ThuFLEP and conventional HoLEP are clinically comparable with no definitive superiority of either laser. Platform selection should be individualised according to surgeon expertise, institutional resources, and patient characteristics. Future trials should standardise cost-effectiveness outcomes and investigate whether the distinct laser-tissue interactions impact adenoma clearance, PSA reduction, enucleation completeness, and long-term durability.

Humans

Excimer laser angioplasty for acute coronary occlusion: a stratified meta-analysis of efficacy against aspiration thrombectomy and conventional PCI.

Primary percutaneous coronary intervention (PCI) achieves epicardial reperfusion in most STEMI patients, yet microvascular obstruction persists in up to 60% of patients. Excimer laser coronary angioplasty (ELCA) vaporizes thrombus in situ and may reduce distal embolization, but the evidence base has not been systematically synthesized. This systematic review and meta-analysis (PROSPERO CRD420261422463) included comparative studies of adjunctive ELCA versus aspiration thrombectomy (Stratum A) or PCI alone (Stratum B) in acute coronary occlusion. Primary outcomes were final TIMI-3 flow and myocardial blush grade (MBG) 3; secondary outcomes were short-term mortality, MACCE, and slow-flow/no-reflow. A random-effects model with Hartung-Knapp-Sidik-Jonkman confidence intervals was applied to all outcomes. Certainty was assessed with GRADE. Ten studies (1 RCT, 9 observational) were included, from a total enrolled population exceeding 3,500. In Stratum A, no outcome reached significance: MBG-3 (OR 3.57, 95% CI 0.07-185.10), mortality (OR 0.31, 0.02-4.04), MACCE (OR 0.22, 0.04-1.26), TIMI-3 flow (OR 1.58, 0.67-3.75) and slow-flow/no-reflow (OR 0.78, 0.22-2.78). In Stratum B, using each study's propensity-matched data, no outcome differed significantly (TIMI-3 OR 0.88, 0.38-2.03; MBG-3 OR 1.06, 0.13-8.43; slow-flow/no-reflow OR 0.93, 0.29-3.02; mortality OR 0.44, 0.05-3.80). Composite endpoints were not pooled across incompatible follow-up horizons, and all outcomes were of very low certainty. Adjunctive ELCA-containing strategies during primary PCI were not associated with improved angiographic or short-term clinical outcomes against either comparator. Multicenter randomized trials are required before recommending clinical adoption.

Humans

Intraoperative indocyanine green near-infrared fluorescence imaging for assessing testicular viability in pediatric testicular torsion: A retrospective study.

OBJECTIVE: To evaluate the clinical efficacy of indocyanine green near-infrared fluorescence (ICG-NIRF) imaging versus conventional surgery for assessing testicular viability and guiding decision-making in pediatric testicular torsion (TT). METHODS: A retrospective analysis was performed on 225 pediatric patients undergoing emergency scrotal exploration for TT between January 2019 and January 2025. Patients were categorized into a conventional surgery group (n = 118) relying on visual grading and an ICG-NIRF imaging group (n = 107). Primary outcomes included intraoperative testicular preservation rates and postoperative success rates. Multivariate Cox regression was utilized to identify factors influencing testicular preservation. RESULTS: Baseline characteristics were comparable between groups. The ICG-NIRF group demonstrated a significantly higher intraoperative preservation rate (74.77% vs. 61.02%, p = 0.028) and postoperative success rate (88.75% vs. 69.44%, p = 0.003) compared to the conventional group. Additionally, the ICG-NIRF group exhibited significantly lower rates of secondary orchiectomy (1.25% vs. 9.72%, p = 0.027) and 6-month testicular atrophy (7.59% vs. 23.08%, p = 0.02). Multivariate analysis confirmed ICG-NIRF application as an independent protective factor for testicular preservation (HR = 0.556, p < 0.001). CONCLUSION: ICG-NIRF imaging provides an objective, real-time assessment of testicular perfusion, significantly improving testicular preservation rates and postoperative outcomes. This technique overcomes the subjectivity of conventional visual methods, offering substantial clinical value for fertility preservation in pediatric TT.

Humans

Efficacy of high-intensity laser therapy versus ultrasound therapy in patients with knee osteoarthritis: a randomized controlled trial.

PURPOSE: High-intensity laser therapy (HILT) and ultrasound (US) are widely used for knee osteoarthritis (KOA), but comparative efficacy data remain scarce. This study compared HILT and US as exercise adjuncts in patients with KOA. METHODS: In this single-center, assessor-blinded RCT, 66 adults with KOA were randomized 1:1 to HILT or US twice weekly for 6&#xa0;weeks as exercise adjuncts. The primary outcome was WOMAC total score change from baseline to 12&#xa0;weeks post-treatment (minimum important change [MIC]&#x2009;=&#x2009;10 points, applied as an approximation). Secondary outcomes included VAS, OKS, KOOS, and EQ-5D-5L. RESULTS: In ITT analysis (N&#x2009;=&#x2009;66), the HILT group achieved a mean WOMAC reduction of 40.0 vs 8.2 points (adjusted between-group difference: -27.7 points, 95% CI:&#x2009;-&#x2009;39.0 to&#x2009;-&#x2009;16.5; p&#x2009;<&#x2009;0.001, partial &#x3b7;2&#x2009;=&#x2009;0.277). At 12&#xa0;weeks post-treatment, greater improvements across all secondary outcomes were observed in exploratory analyses (p&#x2009;&#x2264;&#x2009;0.012). Furthermore, HILT maintained therapeutic effects up to 12&#xa0;weeks post-treatment, whereas the US group experienced a gradual loss of post-treatment gains. CONCLUSION: HILT combined with exercise produced greater short-term improvements in WOMAC total score than US in patients with KOA, with exploratory findings suggesting consistent benefits in pain, function, and quality of life, and with benefits maintained up to 12&#xa0;weeks after the last treatment session.

Humans

The use of diode laser and scalpel blade in stage-two dental implant surgery: a comparative study.

OBJECTIVE: The use of lasers in dental implant procedures raises questions regarding the preservation of keratinized tissues and implant outcomes. This study aimed to compare the clinical effects (pain and impression time) and soft tissue healing (keratinization, peri-implant probing, bleeding, and healing) of diode lasers and scalpels used during stage-two dental implant surgery. METHOD AND MATERIALS: A prospective randomized clinical trial with a 1:1 allocation ratio was conducted. The study included 30 patients, each with a single, fully osseointegrated implant. Patients were categorized into two groups. The study group underwent stage-two implant surgery using a 970-nm diode laser. In the control group, implants were exposed using a conventional surgical blade. A comparison between the diode laser and conventional scalpel groups was made based on clinical outcomes (pain and impression time) and soft tissue healing (keratinization, peri-implant probing, bleeding, and healing). Data were analyzed using a paired t test. RESULTS: Pain intensity significantly decreased from immediate postoperative to 7 days in both scalpel (49.87 &#xb1; 6.78, t = 28.48, df = 14, P .001) and diode laser (7.67 &#xb1; 7.58, t = 3.91, df = 14, P = .002) groups. Immediately after surgery, pain scores were significantly higher in the scalpel group compared with the diode laser group (94.53 &#xb1; 4.45 vs 46.93 &#xb1; 5.85, t = 25.076, df = 26.151, P .001). Although pain decreased in both groups by day 7, the scalpel group continued to exhibit significantly greater pain (44.67 &#xb1; 5.96 vs 39.27 &#xb1; 3.73, t = 2.974, df = 23.513, P = .007). Impression time (P = .231) and gingival keratinized tissue (P = .736) did not differ significantly between the scalpel and diode laser approaches. At week 6, the scalpel group exhibited a significantly higher mean peri-implant bleeding index (2.60 &#xb1; 0.507) compared with the laser group (0.07 &#xb1; 0.258, P .001). However, after 12 weeks, no significant difference was observed (1.58 &#xb1; 0.19 vs 1.55 &#xb1; 0.21, P = .748). Laser surgery produced significantly better early wound healing at all intervals (P .001), while intraoperative bleeding was more common with the scalpel technique than with the diode laser (100.0% vs 66.7%, P = .042). CONCLUSION: Compared with the scalpel method, the diode laser method resulted in a significant reduction in pain intensity, improved wound healing, and less peri-implant bleeding during the stage-two dental implant surgery.

Humans

Simultaneous determination of imiquimod and terbinafine in skin permeation studies: Validation of a liquid chromatography method with fluorescence detection.

Chromoblastomycosis is a chronic, neglected subcutaneous mycosis posing significant therapeutic challenges. A topical strategy combining terbinafine (TBF), an antifungal, with imiquimod (IMQ), a TLR-7/8 agonist immunomodulator, has emerged a promising alternative. However, no validated analytical method is currently available to simultaneously quantify both drugs in skin, which is crucial for novel formulation development. This study reports the development and validation of a simple HPLC method with fluorescence detection (excitation 236&#xa0;nm, emission 340&#xa0;nm) for the simultaneous determination of TBF and IMQ extracted from porcine skin. Separation was achieved on a C8 reversed-phase column (125&#xa0;&#xd7;&#xa0;4.0&#xa0;mm, 5&#xa0;&#x3bc;m) using a mobile phase of methanol and water (60,40, v/v), both containing 0.1% formic acid at a flow rate of 0.8&#xa0;mL/min. The method showed excellent linearity (r&#xa0;>&#xa0;0.999) over 0.01-1.0&#xa0;&#x3bc;g/mL for IMQ and 0.1-2.0&#xa0;&#x3bc;g/mL for TBF. Intra- and inter-day precision demonstrated coefficients of variation below 5%, and recovery rates from skin (79-105%) confirmed accuracy. Limits of detection were 0.001&#xa0;&#x3bc;g/mL for IMQ and 0.004&#xa0;&#x3bc;g/mL for TBF, with quantification limits of 0.02&#xa0;&#x3bc;g/mL and 0.16&#xa0;&#x3bc;g/mL, respectively. This selective, sensitive, and reproducible method represents a valuable analytical tool for supporting the development and quality control of topical formulations for chromoblastomycosis and other fungal skin diseases.

Animals

Topical Carboxytherapy as an Adjunct to Skin Recovery Post-CO2 Laser Fractional Resurfacing.

BACKGROUND: Topical carboxytherapy, a transcutaneous carbon dioxide (CO2) delivery system, may support skin repair and regeneration, yet its role as an adjunct to fractional laser treatment remains underexplored. OBJECTIVE: To investigate the effectiveness and safety of topical CO2 mask (CO2Lift&reg; Carboxy Gel, Lumisque Skincare) in supporting skin recovery and improving clinical outcomes following fractional CO2 laser resurfacing. METHOD: This 12-week randomized, placebo-controlled trial evaluated mild-to-moderate photoaging (n=6 females only). Participants received either topical carboxytherapy (n=4) or standard care (n=2). Assessments included VISIA-CR imaging, biophysical measurements, investigator ratings, and paired (baseline and 4-week) skin biopsies. RESULTS: Topical carboxytherapy accelerated recovery and was well-tolerated, with no major adverse events. VISIA-CR imaging showed accelerated erythema resolution, transepidermal water loss normalized more rapidly, and pH remained stable. Skin histology at week 4 revealed epidermal thickening and rete ridge formation with topical carboxytherapy vs placebo. Investigator ratings demonstrated significantly improved healing, global assessment, and global aesthetic improvement scale scores, with trends toward improvement in photodamage, rhytides, and pigmentation. CONCLUSION: Adjunctive topical carboxytherapy after fractional CO2 resurfacing accelerated healing, improved barrier recovery, and overall aesthetic outcomes. Larger studies are needed to confirm these findings.

Humans

Application of Perioperative Real-Time Fluorescence Imaging to Achieve High-Quality Debridement: A Randomized Control Trial.

OBJECTIVE: To investigate the effectiveness of real-time fluorescence imaging (RTFI)-assisted debridement in managing chronic wounds compared with standard surgical debridement. APPROACH: This study was a patient-blinded, randomized clinical trial conducted from February 17, 2021, to July 30, 2021, on patients with chronic wounds. Patients were randomized to an RTFI group (M group) or conventional group (C group). The primary outcomes were as follows: percentage of residual bacterial area (preoperative and postoperative), number of debridements, high-quality debridement ratio, operation duration, and wound healing duration. RESULTS: A total of 100 patients were enrolled in both groups. No significant difference in the percentage of preoperative residual bacterial area or high-quality debridement ratio was seen. The M group underwent debridement an average of 2.6 times and had a significantly longer duration of operation (33.5 &#xb1; 12.7 min) than the C group (29.9 &#xb1; 10.4 min; p = 0.031). The postoperative residual bacterial area was significantly lower in the M than in the C group (6.83% &#xb1; 1.39% vs. 30.0% &#xb1; 12.37%, respectively; p < 0.001). The M group required significantly fewer wound healing days (49.2 &#xb1; 25.3 vs. 63.0 &#xb1; 27.9, p < 0.001). Secondary outcomes also demonstrated statistically significant differences in total hospitalized days (17.5 &#xb1; 9.3 vs. 21.5 &#xb1; 12.5, p < 0.01), days of antibiotic use (15.5 &#xb1; 8.7 vs. 18.7 &#xb1; 6.7, p < 0.01), and reinfection rates (4 of 100 vs. 22 of 100, p < 0.001). INNOVATION: RTFI can detect signals from normal skin components and bacterial metabolites. Therefore, interpretation of RTFI results should be correlated with the clinical condition. RTFI is associated with high-quality debridement. This technique can also be applied in targeted biopsy and in training young staff to mature debridement procedures. CONCLUSION: RTFI in debridement is associated with favorable clinical outcomes and may have a positive influence on chronic wound healing.

Humans

Viscoelastic-Assisted Patient Interface Docking: A Technical Optimization in LenSx Femtosecond Laser-Assisted Cataract Surgery.

PURPOSE: To evaluate the efficacy of viscoelastic-assisted patient interface docking in LenSx (Alcon Laboratories, Inc) femtosecond laser-assisted cataract surgery (FLACS). METHODS: This was a randomized controlled trial. Patients undergoing FLACS from January to August 2025 at Aier Eye Hospital of Wuhan University were randomized via a random number table to receive balanced salt solution (BSS) or visoeleastic as the patient interface docking medium. The primary outcome was docking efficiency, measured by one-time docking success rate, the number of docking attempts, and mean docking time. Secondary outcomes included surgical safety (subconjunctival hemorrhage, capsulotomy completeness/tear rate), laser treatment duration (anterior capsulotomy time, nucleus pretreatment time, total laser emission time), and patient comfort (post-laser pain sensation). RESULTS: A total of 100 patients were enrolled, 50 in each group. Suction loss occurred in 7 patients (14%) in the BSS group and 1 patient (2%) in the viscoelastic group; the one-time docking success rate was significantly higher in the viscoelastic group (98%) than in the BSS group (86%) (chi-square = 3.93, P < .05). The viscoelastic group also had fewer mean docking attempts (1.02 &#xb1; 0.14) than the BSS group (1.16 &#xb1; 0.42), showing a significant difference (t = 2.23, P < .05). The viscoelastic group exhibited significantly shorter mean docking time (44.66 &#xb1; 4.47 seconds) compared to the BSS group (48.62 &#xb1; 3.11 seconds) (t = 2.17, P < .05). No significant differences were observed between the groups in subconjunctival hemorrhage, capsulotomy completeness/tear rate, anterior capsulotomy time, nucleus pretreatment time, total femtosecond laser emission time, or patient-reported pain sensation (all P > .05). CONCLUSIONS: Viscoelastic-assisted patient interface docking in FLACS effectively elevates one-time docking success rate, reduces docking attempts, and shortens docking time.

Humans

Rates, Timing, and Predictors of Retreatment Across Risk-Cohorts in Retinopathy of Prematurity: Intravitreal Bevacizumab Injection Versus Laser.

OBJECTIVE: To characterize rates, timing, and predictors of retinopathy of prematurity (ROP) retreatment among infants treated with primary laser or intravitreal bevacizumab injection. DESIGN: Retrospective consecutive, comparative clinical study. PARTICIPANTS: Infants who underwent initial treatment for treatment-warranted ROP (TW-ROP) with either intravitreal bevacizumab or laser photocoagulation between 2017 and 2023. METHODS: Patients were stratified into two treatment groups: primary laser group vs primary bevacizumab group. MAIN OUTCOME MEASURES: Retreatment within the first 3 months (0-90 days) was assessed and classified as early (&#x2264;30 days) or late (31-90 days). RESULTS: Two hundred and thirty eight eyes of 122 infants were treated for ROP; of those, 181 (76.1%) eyes of 93 (76.2%) patients were included. There were 116 (64.1%) eyes in the bevacizumab group, and 65 (35.9%) eyes in the laser group. Thirty-three (18.2%) eyes-all micro- or nano-premature (<27 weeks GA and/or <800 grams)-required retreatment for TW-ROP. Sixteen (8.8%) required early retreatment at a median postmenstrual age (PMA) of 40.4 weeks (IQR, 38.44-43.3). There were differences in the proportion of early retreated infants (21.5% for laser vs 1.7% for injection, P < .001). Seventeen (9.4%) eyes required late retreatment. The median PMA at late retreatment was 45.6 weeks (IQR, 43.7-47.4). Infants in the bevacizumab group had lower odds of retreatment within three months than those with laser (OR, 0.23; 95% CI, 0.06-0.82). Similarly, patients in the bevacizumab group had lower odds of requiring early retreatment compared to those with laser (OR, 0.08; 95% CI, 0.04-0.18). Within eyes with retreatment, infants in the bevacizumab group had a later PMA at retreatment than those in the laser group (B = 6.81; 95% CI: 4.68-8.93). AROP was associated with earlier PMA at retreatment (B = -7.72; 95% CI, -9.36 to -6.10). CONCLUSION: In this study, early retreatment was low (8.8%), with most eyes initially treated with laser (21.5%) rather than bevacizumab (1.7%). Aggressive ROP was associated with earlier retreatment, highlighting its role as a marker of more severe disease. Compared to laser, bevacizumab was associated with lower overall and early retreatment, and delayed need for additional intervention when necessary. All retreatments occurred in micro- or nano-premature infants, suggesting that medium-to-low risk infants may require less strict post-treatment monitoring.

Humans

Skin barrier repairing and anti-aging effects evaluation of a comprehensive topical regimen incorporating niacinamide, Pro-Xylane, and panthenol after PicoWay laser: a randomized controlled study.

Pro-Xylane is a potent anti-aging ingredient; however, there is limited knowledge regarding whether a comprehensive post-procedure regimen incorporating a combination of Pro-Xylane, niacinamide, and panthenol alongside other active agents can deliver synergistic benefits for both skin barrier repair and anti-aging. This study assesses the effectiveness of the REGENMEDIC cream (anti-aging cream) and REGENMEDIC serum (anti-aging serum) in promoting skin barrier recovery and enhancing anti-aging effects following PicoWay laser treatment. A 112-day randomized controlled trial was conducted with 88 Chinese females, who were divided into two groups: the test group, using REGENMEDIC cream and Serum following PicoWay laser treatment, and the control group, using standard care regimen consisting of a standard cream. Skin barrier-repairing effects were assessed during the initial 14 days following a single use of REGENMEDIC cream, while skin elasticity, firmness, wrinkles and skin tone were evaluated over the 112-day study period after the combined use of REGENMEDIC cream and Serum. The test group exhibited lower transepidermal water loss (TEWL) and higher hydration after 14 days compared to the control group, along with a more significant reduction in skin redness. After 112-day use of REGENMEDIC cream and serum, test group showed increased skin elasticity and firmness, reduced wrinkles, and an overall improvement in skin tone and texture. Dermatologists reported excellent tolerability, with minimal adverse events. Initial application of the REGENMEDIC cream facilitated rapid skin barrier repair, while the subsequent sequential regimen incorporating the serum yielded significant long-term anti-aging benefits following PicoWay laser treatment. This study demonstrates that targeting multiple physiological pathways-specifically hydration, barrier integrity, and cellular senescence-provides a robust therapeutic option for amplifying the anti-aging outcomes of aesthetic procedures.

Humans

Effectiveness of STK Spray&#xae; for semen stain localization on solid surfaces: A specificity and sensitivity study.

Semen identification is a crucial step in sexual assault cases. The aim of this study was to assess STK Spray&#xae;, a presumptive test for semen, under controlled conditions including, simulated crime scene stains detection. Easy to use, it can be sprayed directly onto different surfaces and visualized under UV light. Several tests were performed on five different substrates (ceramic tile, drywall, metal, wood, and faux leather). The spray was able to enhance semen fluorescence, especially in diluted samples, with characteristic "globular" spots. Although it showed good specificity, false positives could be obtained with 10% bleach. The fluorescence signals were quantified using ImageJ&#x2122; and showed a statistically significant substrate-dependent variability. Mixture analysis indicated that saliva did not interfere with detection of semen, while urine partially suppressed the signal and blood markedly affected its interpretation. Simulation tests with UV lamp comparisons confirmed the importance of choosing the right detection method and the utility of this presumptive test in combination with additional immunochromatographic tests. A preliminary signal retention test showed stable fluorescence for up to two years when stains were stored appropriately. Finally, complete DNA profiles (100% of alleles) were obtained from all samples (n&#xa0;=&#xa0;24) after exposure to the reagent and UV light. Because of its ability to enhance semen signal, especially on specific surfaces, and its rapidity of use and detection, STK Spray&#xae; may represent a useful aid in the preliminary screening phase.

Humans

A STORM-based protocol for nanoscale imaging and quantitative analysis of protein-associated and phospholipid-associated structures in natural rubber.

Stochastic Optical Reconstruction Microscopy (STORM) enables nanoscale mapping of molecular components beyond the diffraction limit; however, its reproducible implementation in hydrophobic polymer matrices remains challenging because fluorescence-labeling specificity, fluorophore photoswitching, three-dimensional localization, chromatic registration, and quantitative image analysis must be carefully controlled. This protocol presents a standardized experimental workflow for dual-color labeling, astigmatism-based three-dimensional STORM acquisition, and quantitative analysis of protein-associated and phospholipid-associated structures in natural rubber (NR). The workflow covers sample pretreatment, Cy5 NHS ester labeling of protein-associated primary amines, DiI labeling of phospholipid-rich domains, STORM imaging-buffer preparation, three-dimensional single-molecule localization, dual-channel registration, generation of standardized xy projections, aggregate-size analysis, and projected lateral spatial correlation assessment. Reproducibility is supported by defined acquisition and localization criteria, three independent sample preparations with at least five fields of view analyzed per condition, and unlabeled, single-color, dye-only matrix, and processing-associated Cy5 controls. Mean lateral localization precisions of 11.8&#x202f;&#xb1;&#x202f;2.3&#x202f;nm for Cy5 and 13.5&#x202f;&#xb1;&#x202f;2.9&#x202f;nm for DiI were obtained, while two-dimensional Fourier ring correlation analysis of the xy projections yielded effective lateral image resolutions of approximately 25 and 28&#x202f;nm, respectively. Image-based particle segmentation and localization-coordinate-based density-based spatial clustering of applications with noise (DBSCAN) were applied to standardized xy projections as complementary quantitative approaches. Application of the protocol to untreated, centrifuged, and protease-treated NR samples demonstrated treatment-associated changes in the detected abundance and projected size distributions of protein- and phospholipid-associated aggregates, together with a non-monotonic change in their projected lateral spatial correlation. These observations describe alterations in nanoscale organization but do not, by themselves, establish stable protein-phospholipid complex formation. Unlike previous studies that primarily demonstrated the feasibility of STORM imaging in rubber materials, the principal contribution of this work is an end-to-end, step-by-step protocol incorporating defined controls, three-dimensional localization, image-quality metrics, chromatic-registration procedures, and complementary quantitative-analysis pipelines for non-expert users. The workflow may be adaptable to other hydrophobic polymers and soft-material systems after appropriate optimization and validation.

Rubber