Search PubMedSearch

SEARCH · Search PubMed

Results for “Transthoracic needle biopsy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

59 recordsLinked to original sources

Robotic-assisted transbronchial biopsy versus computed tomography-guided transthoracic needle biopsy for peripheral pulmonary lesions: a systematic review and meta-analysis of direct comparative studies.

Robotic-assisted bronchoscopy (RAB) and computed tomography-guided transthoracic biopsy (CTTB) are competing strategies for sampling peripheral pulmonary lesions (PPLs). Whether they differ in yield or safety is uncertain. To our knowledge, this is the first systematic review restricted to direct comparisons. We searched MEDLINE, Europe PMC, Scopus, Web of Science and ClinicalTrials.gov from inception to 7 July 2026 for studies directly comparing RAB with CTTB in adults with PPLs. The primary outcome was strict 2024 American Thoracic Society/American College of Chest Physicians diagnostic yield. Risk of bias was assessed with ROBINS-I and certainty with GRADE. A cohort-genealogy step identified, per outcome, the largest set of cohorts sharing no patients; only that set was pooled, with Hartung-Knapp and Mantel-Haenszel sensitivity analyses. Five retrospective studies from one US health system were eligible. Four share patients; at most three cohorts are mutually independent. Across those three, diagnostic yield was comparable (risk ratio [RR] 0.99, 95% confidence interval [CI] 0.93-1.06; I²=24%; Hartung-Knapp 0.87-1.13), with an identical relative effect under strict and intermediate definitions although absolute yields fell from 88% to 74-84% under strict criteria. Pneumothorax requiring a chest tube and/or admission was about three-quarters less frequent with RAB across all three cohorts (RR 0.25, 95% CI 0.14-0.46; I²=0%; Hartung-Knapp 0.07-0.96). Strict yield (RR 0.99) and any pneumothorax (RR 0.06) were reported by two cohorts each and neither survives the few-studies correction. RAB took about 50 min longer than CTTB where same-session staging endobronchial ultrasound was counted in the robotic time, but only about 8 min longer than CTTB where it was not. Only one cohort reported yield by lesion size category and none reported yield by bronchus sign or lung zone, so lesion-level subgroups could not be pooled. Certainty was low for pleural complications and very low elsewhere. Low-certainty evidence indicates that RAB is associated with fewer pleural complications, with no statistically detectable difference in diagnostic yield; equivalence was not formally established. Because all evidence is retrospective, confined to one health system, and almost never stratified by lesion size or accessibility, these findings are hypothesis-generating and require a multicenter randomized trial.

Humans

Robotic Needle Insertion for CT-guided Percutaneous Biopsy of Thoracoabdominal Lesions: A Prospective Multicenter Randomized Trial.

Purpose To compare safety and feasibility between a novel CT-guided robotic system and the conventional freehand technique for puncture biopsy of thoracoabdominal lesions. Materials and Methods In this prospective multicenter randomized trial, individuals with suspected lesions were enrolled between July 2023 and April 2024 across three university teaching hospitals and randomized to the robot-assisted group (n = 82) or the freehand group (n = 83). Procedure outcomes included the technical success rate, targeting error, number of CT scans and needle adjustments, puncture time, and complications. Descriptive and inferential statistics were calculated. Results A total of 165 participants (mean age, 60 years &#xb1; 10 [SD]; 83 male) were included. Compared with the freehand group, the robot-assisted group demonstrated a higher technical success rate (97.56% [80 of 82] vs 62.65% [52 of 83], P < .001), lower targeting error (mean Euclidean deviation: 1.7 mm &#xb1; 1.1 vs 4.5 mm &#xb1; 3.9, P < .001), and fewer CT scans (mean, 4.3 &#xb1; 1.9 vs 5.2 &#xb1; 2.3; P = .002) and needle adjustments (mean, 0.7 &#xb1; 0.7 vs 1.6 &#xb1; 1.6; P = .003). Despite differences in geometric precision, both groups achieved 100% (82 of 82 and 83 of 83) diagnostic yield. The median puncture time was comparable between groups (5.5 minutes &#xb1; 4.3 vs 4.8 minutes &#xb1; 7.0, P = .50). During lung biopsies, the robot-assisted approach yielded fewer complications compared with the freehand approach (4.88% [four of 82] vs 16.87% [14 of 83], P = .014). Conclusion Compared with the freehand approach, robot-assisted biopsy yielded greater precision and reduced adjustments and complications while demonstrating noninferior diagnostic efficacy and comparable duration. Keywords: Robotic Needle Insertion, Biopsy, Thoracoabdominal Lesions, Robot-assisted Biopsy, CT-guided Intervention, Percutaneous Needle Biopsy, Randomized Controlled Trial, Algorithm Development, CT, Clinical Testing, Interventional-Body, Biopsy/Needle Aspiration, Percutaneous, Thorax, Abdomen/GI, Liver, Lung, Kidney &#xa9;RSNA, 2026.

Humans

Complication rates of 16- and 18-gauge needles for native kidney biopsies: a systematic review and proportional meta-analysis.

This systematic review and meta-analysis evaluated complication rates and diagnostic yield reported in studies of adult native kidney biopsy using 16-gauge (16&#x2009;G) or 18-gauge (18&#x2009;G) needles. We included randomized trials and cohort studies of real-time ultrasound-guided biopsies, including case series. MEDLINE, Embase, and CENTRAL were searched through October 2024. Two reviewers independently performed study selection, data extraction, and risk of bias assessment using Joanna Briggs Institute tools. Random-effects meta-analyses estimated pooled proportions with 95% confidence intervals (CI), and univariable random-effects meta-regression explored study-level associations with major complications, transfusion, or gross hematuria. We screened 4,499 titles and abstracts and reviewed 319 full-text articles; 62 studies comprising 68 biopsy series were included. The pooled major complication rate in studies using 16&#x2009;G needles was 1.83% (95% CI: 1.20-2.79) and 1.29% (95% CI: 0.78-2.13) in studies using 18&#x2009;G needles, with no statistically significant difference. Mean glomerular yield was 18.8 with 16&#x2009;G and 17.5 with 18&#x2009;G needles. In study-level meta-regression, studies with higher prevalence of acute kidney injury, lower mean estimated glomerular filtration rate, or lower mean hemoglobin reported higher pooled complication rates. Most studies were single-arm cohorts; between-needle differences therefore reflect indirect study-level contrasts. Interpretation is limited by retrospective design and heterogeneity across studies. Overall, studies using both needle sizes reported low complication rates and similar diagnostic yield, although definitions and reporting varied. Direct comparative studies are needed to determine whether meaningful differences exist.

Humans

Endoscopic Ultrasound-Guided Franseen Fine-Needle Biopsy for Solid Pancreatic Lesions: A Systematic Review and Meta-Analysis.

INTRODUCTION: Accurate tissue acquisition (TA) of solid pancreatic lesions is essential for guiding treatment with endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) being the preferred method. Among FNB designs, the three-pronged Franseen-tip needle demonstrates strong diagnostic performance, though direct head-to-head comparisons with other FNB designs remain limited. METHODOLOGY: This meta-analysis was conducted in accordance with PRISMA guidelines (PROSPERO: CRD420251123856). Eligible studies enrolled patients with solid pancreatic lesions who underwent EUS-guided FNB, directly compared the Franseen-tip with other FNB needles. Six databases were systematically searched through July 2025, and study selection, data extraction, and risk of bias assessment (QUADAS-2 tool) were performed independently by two reviewers. Pooled estimates were generated using random-effects and bivariate hierarchical models. RESULTS: Sixteen studies (2,010 Franseen vs. 2,811 comparator) were included. Bivariate analysis showed that sensitivity and specificity of the Franseen needle were comparable to newer-generation comparator needles (sensitivity 91.3% vs. 94.0%; specificity 99.99% vs. 99.15%), whereas older-generation needles demonstrated lower sensitivity (80.8%) and inferior discriminatory performance (Negative Likelihood Ratio [LR&#x207b;] 0.19 vs. 0.09). Diagnostic accuracy was higher with the Franseen needle (RR 1.07, 95% CI 1.01-1.14; I2&#x2009;=&#x2009;69%). Sample adequacy was similar overall (RR 1.04, 95% CI 0.95-1.14) but superior to older-generation needles (RR 1.19, 95% CI 1.02-1.41) and in lesions&#x2009;>&#x2009;30&#xa0;mm (RR 1.14, 95% CI 1.02-1.28, I2&#x2009;=&#x2009;81.2%). The Franseen needle achieved nominally strong diagnostic performance (DOR 116.6), although small-study effects were observed. Primary procedural outcomes were comparable between Franseen and comparator needles, including technical success (RR 1.00, 95% CI 0.98-1.02) and histological core procurement (RR 1.04, 95% CI 0.92-1.17). The Franseen needle had fewer low-cellularity samples (RR 0.56, 95% CI 0.45-0.69) and lower specimen bloodiness (RR 0.48, 95% CI 0.25-0.90) but a slightly higher overall adverse event rate (RR 1.29, 95% CI 1.06-1.57). CONCLUSION: The Franseen needle provides superior diagnostic accuracy and sample adequacy compared to older-generation FNB needles with comparable performance to newer-generation designs. It reduces low-cellularity samples and specimen bloodiness, although adverse events are slightly increased, with other primary procedural outcomes remaining comparable. TRIAL REGISTRATION: PROSPERO (Registration No. CRD420251123856).

Humans

Primary pulmonary salivary gland-type tumors in cytopathology practice: A systematic review and meta-analysis.

BACKGROUND: Primary pulmonary salivary gland-type tumors (PSGTs) are rare but clinically significant tumors that originate from the submucosal glands of the tracheobronchial tree. Cytologic samples taken during bronchoscopy are a key component of preoperative evaluation. However, cytologic diagnosis remains challenging because of the submucosal growth and morphologic overlap of PSGTs. In addition, current knowledge of the cytohistologic correlation of PSGTs is fragmented. The objective of this study was to assess the effectiveness of cytologic diagnoses of PSGTs. METHODS: A comprehensive, systematic literature search of the PubMed database was conducted to identify studies with cytologic and histologic diagnoses of PSGTs. Comprehensive data on diagnostic and clinical factors, when available, were collected for all individual patients. The data were tabulated in Microsoft Excel and analyzed using OpenMeta (Analyst) software. RESULTS: In total, 49 studies comprising 106 patients were identified. Final cytohistologic concordance was demonstrated in 48.1% of cases. Fine-needle aspiration showed the highest sensitivity (75.0%), followed by bronchial/tracheal washing (38.1%), and bronchial brushing (34.2%). Adenoid cystic carcinoma was the most common histologic subtype, accounting for 67 cases, followed by mucoepidermoid carcinoma, which accounted for 27 cases. CONCLUSIONS: The cytologic diagnosis of rare PSGTs remains challenging. Overall, cytohistologic concordance was 48.1%. However, fine-needle aspiration demonstrated greater diagnostic accuracy than exfoliative cytology and may facilitate a more accurate preoperative assessment.

Humans

Diagnostic utility of high-risk HPV polymerase chain reaction-based testing in head and neck FNA specimens with indeterminate cytomorphology.

BACKGROUND: Fine-needle aspiration (FNA) is critical in the initial diagnosis of many high-risk human papillomavirus (HR-HPV)-associated, metastatic oropharyngeal squamous cell carcinomas. Updated guidelines recommend HR-HPV-specific polymerase chain reaction (PCR) analysis over p16 immunohistochemistry on FNA specimens because p16 performs poorly on cytology material. PCR-based assays on liquid cytology material have demonstrated excellent analytic performance; however, the diagnostic utility of a positive HR-HPV PCR result in specimens with indeterminate cytomorphology remains uncharacterized. METHODS: The authors retrospectively identified 279 head and neck FNA specimens that had paired HR-HPV PCR testing on residual liquid cytology material over a 5-year period. The positive predictive value for histopathologically confirmed squamous cell carcinoma on surgical follow-up was calculated within each cytologic interpretive category. RESULTS: The HR-HPV PCR results were positive in 50.2% of specimens, negative in 40.9%, and indeterminate in 9.0%. The HR-HPV positivity rate ranged from 0% in specimens categorized as negative for malignancy to 57.3% in cytologically positive specimens, with 19.0%, 41.2%, and 50.0% positivity in the atypical, suspicious, and nondiagnostic categories, respectively. Among cytologically indeterminate specimens with positive HR-HPV PCR results (n&#xa0;=&#xa0;14), the positive predictive value was 100% (95% confidence interval, 78.5%-100.0%). Blinded slide review additionally identified 15 cytologically positive specimens in which the definitive malignant interpretation depended substantially on HR-HPV positivity; all 15 were confirmed as squamous cell carcinoma. CONCLUSIONS: A positive HR-HPV PCR result on liquid cytology material carries a positive predictive value of 100% for malignancy in cytologically indeterminate head&#xa0;and neck FNA specimens. These findings support integrating HR-HPV PCR analysis into routine cytologic interpretation with the potential to upgrade some indeterminate specimens to malignant when HR-HPV is detected, expediting definitive treatment and sparing patients additional, invasive sampling.

Humans

Analyzing the impact of subcutaneous injection needle, device, and administration characteristics on patient pain, anxiety, and safety: a systematic literature review.

The subcutaneous (SC) injection route is a commonly used and important method for therapeutic delivery of a wide range of compounds, and needle characteristics have a significant influence on patient pain, anxiety, safety, and other outcomes. This systematic review evaluates the evidence on how needle-specific characteristics (e.g. gauge, length, tip design, wall thickness, concealment) and administration- or device-related factors can affect patient-reported outcomes and clinical safety indicators during and following SC injections. A comprehensive search was conducted in MEDLINE, PubMed, Embase, and ClinicalTrials.gov in June 2024. Studies were included if they assessed the relationship between needle characteristics and pain, anxiety, safety, or related outcomes in individuals receiving SC injections. A dual-reviewer process was used for study selection, data extraction, and quality assessment. Sixty-two studies met inclusion criteria. Evidence consistently indicated that thinner and shorter needles reduced patient-reported pain and adverse events such as bruising and bleeding. Tapered and lubricated needles, hidden or retractable needle designs, and use of autoinjectors or prefilled syringes also contributed to reduced anxiety and improved user satisfaction. However, results were heterogeneous, and many studies lacked sufficient power or single-variable evaluation of individual needle parameters, limiting definitive conclusions. Needle characteristics significantly influence patient experience and safety with SC delivery. While both clinical evidence and practical experience clearly favor thinner, shorter, and concealed needles, further standardized, high-quality research is needed to isolate and quantify the specific contributions of individual needle characteristics to optimize injection practices and support patient-centered device design.

Humans

Risk factors and management strategies for needle disengagement from the visual field in pediatric robot-assisted laparoscopic pyeloplasty.

OBJECTIVE: This study aimed to identify risk factors for suture needle disengagement from the visual field during pediatric robot-assisted laparoscopic pyeloplasty (RALP) and propose effective strategies for prevention and management. METHODS: A retrospective cohort study analyzed clinical data from 339 pediatric patients who underwent RALP for ureteropelvic junction obstruction (UPJO) at a single institution between August 2017 and December 2020. Patients were categorized based on the occurrence of needle disengagement from the visual field. Various patient demographics and surgical procedural factors were evaluated. Univariate and multivariate logistic regression, along with LASSO regression, identified independent risk and protective factors. RESULTS: Needle disengagement occurred in 38 (11.21%) of 339 cases. Multivariate logistic regression identified five independent risk factors for needle disengagement: use of a 3-mm auxiliary trocar (OR = 4.69, 95% CI: 1.98-12.53, P < 0.001), non-standard needle holder use (OR = 2.32, 95% CI: 1.04-5.18, P = 0.038), unshaped suture needles (OR = 3.16, 95% CI: 1.44-7.19, P = 0.005), simultaneous use of &#x2265;2 intra-abdominal sutures (OR = 2.46, 95% CI: 1.15-5.48, P = 0.023), and clamping the needle shank during withdrawal (OR = 3.42, 95% CI: 1.40-8.21, P = 0.006). Conversely, sufficient assistant experience (>10 cases) was identified as a protective factor (OR = 0.39, 95% CI: 0.18-0.88, P = 0.021). CONCLUSION: Suture needle disengagement from the visual field during pediatric RALP is associated with specific technical and instrumental factors. Implementing targeted strategies-such as mandating specialized needle holders, preoperative needle shaping, a single-needle workflow, prioritizing clamping the suture thread over the needle shank during withdrawal, and ensuring adequate assistant training-has the potential to significantly reduce significantly mitigate the risk of needle loss and enhance overall surgical safety in pediatric RALP.

Humans

[Effect of oblique needling after equal division and positioning of anatomic points on acute sacroiliac joint injury assessed with infrared thermography].

OBJECTIVE: To evaluate the clinical therapeutic effect of oblique needling after equal division and positioning of anatomic points on acute sacroiliac joint injury assessed with infrared thermography. METHODS: A total of 150 patients with acute sacroiliac joint injury were randomly divided into an oblique needling group, a perpendicular needling group, and an acupressure+tuina group, with 50 cases in each group. After equal division and positioning of anatomic points at sacroiliac joints, the oblique needling, perpendicular needling and acupressure+tuina techniques of acupuncture were operated in three groups, respectively. The treatment was administered once daily, 5 sessions per week; 10 sessions constituted one treatment course, with a total of one course required in the trial. Before and after treatment, the scores of Japanese Orthopaedic Association (JOA), visual analogue scale (VAS) of pain, and World Health Organization quality of life-BREF (WHO QOL-BREF), as well as the average temperature of the lumbosacral region were observed in each group. Additionally, the correlation between the average lumbosacral temperature and efficacy indicators was explored. RESULTS: After treatment, the scores of JOA, WHO QOL-BREF in the oblique needling group were higher (P<0.01, P<0.001), and the VAS score was lower (P<0.01, P<0.001) than those in the perpendicular needling group and the acupressure+tuina group; and the average temperature of the affected lumbosacral region in the oblique needling group was lower compared with that in the other two groups (P<0.001). After treatment, the average lumbosacral temperature of the affected side showed a negative correlation with the JOA score in each group (r=-0.645, -0.482, -0.809, P<0.001). CONCLUSION: Following equal division and positioning of anatomic points, the therapeutic effect of acupuncture with oblique needling is superior to the perpendicular needling and acupressure+tuina on acute sacroiliac joint injury. The average temperature of the affected lumbosacral region is correlated with the severity of lumbosacral dysfunction after treatment.

Humans

Phase 1 Study Evaluating Gefurulimab Pharmacokinetics and Safety Following Delivery Via Autoinjector or Prefilled Syringe With Needle Safety Device in Healthy Adults.

PURPOSE: Gefurulimab, a novel dual-binding nanobody targeting complement component 5 (C5), is in clinical development for anti-acetylcholine receptor antibody-positive generalized myasthenia gravis. Gefurulimab has a low molecular weight, enabling subcutaneous (SC) self-administration by autoinjector (AI) or prefilled syringe with needle safety device (PFS-SD). We compared gefurulimab pharmacokinetic (PK) exposure and safety in healthy adults following a single SC dose administered by AI versus PFS-SD. METHODS: In this phase 1, open-label, randomized, parallel-group study (NCT06208488), healthy participants aged 18 to 65 years were stratified by weight and randomized equally to 1 of 6 combination groups of device and injection site (abdomen/thigh/upper arm). Participants received a single SC dose of gefurulimab on day 1 and were assessed throughout the 92-day evaluation period. Primary endpoints were PK parameters for each device: maximum observed concentration (Cmax) and area under the serum concentration-time curve (AUCinf, AUClast). PK across injection sites, pharmacodynamics, safety, immunogenicity, and device performance were also assessed. FINDINGS: Overall, 175 participants were randomized: AI (n = 87), PFS-SD (n = 88). Geometric least squares mean ratios (90% CI) comparing AI/PFS-SD for Cmax, AUCinf, and AUClast were 97.6% (94.5-100.8), 99.6% (96.1-103.3), and 98.8% (95.2&#x2012;102.6), respectively. Secondary analyses found no meaningful differences in PK parameters across injection sites. Serum-free C5 concentrations over time, treatment-emergent adverse event (TEAE) profiles, and antidrug antibody responses were similar between cohorts. Most TEAEs were mild; none led to study discontinuation. IMPLICATIONS: SC administration of gefurulimab by AI and PFS-SD was well tolerated with comparable exposure, meeting bioequivalence criteria.

Humans

Hydrodissection-assisted laparoscopic orchiopexy utilizing needle grasper for palpable undescended testes: Clinical efficacy analysis.

OBJECTIVE: Laparoscopic orchiopexy has emerged as a viable alternative for the treatment of palpable undescended testis (UDT). This study aims to evaluate the feasibility and efficacy of needle-grasper hydrodissection-assisted laparoscopic orchiopexy (NHLO) in comparison to conventional laparoscopic orchiopexy (CLO) for palpable UDT. METHODS: A cohort of 96 patients diagnosed with palpable UDT, admitted between January 2020 and April 2024, was included in this study. Among these, 54 patients underwent NHLO, while 42 patients were treated with CLO. In the NHLO procedure, normal saline was injected into the retroperitoneal space to create a hydrodissection barrier, facilitating the separation and protection of the vas deferens and spermatic cord. The vas deferens and spermatic cord were meticulously dissected following the principles of integrity and minimal tissue trauma. Outcome measures included final testicular position, testicular volume growth, testicular atrophy, success rate, and postoperative complications. RESULTS: No significant differences were observed between the NHLO and CLO groups in terms of age, laterality, operative time (NHLO: 38-46 min; CLO: 39-48 min), or complication rates (NHLO: 1.9 %; CLO: 0.0 %). At follow-up, all patients in both groups exhibited palpable testes in satisfactory scrotal positions. Notably, no visible abdominal scarring was observed in the NHLO group, whereas there were two noticeable scars on the abdomen in CLO. CONCLUSION: Needle-grasper hydrodissection-assisted laparoscopic orchiopexy is a safe, effective, and minimally invasive technique that provides optimal protection of the vas deferens and spermatic cord while achieving excellent cosmetic outcomes.

Humans

PCa Detection in PI-RADS 4 and 5 Lesions: Comparison of [68Ga]Ga-PSMA-11 PET/CT-Guided Robot-Assisted Biopsy Versus mpMRI Cognitive-Fusion TRUS-Guided Prostate Biopsy.

Lesions with a Prostate Imaging-Reporting and Data System (PI-RADS) score of 4 or greater on multiparametric MRI (mpMRI) indicate a high likelihood of prostate cancer (PCa), and guidelines recommend a targeted biopsy. We aimed to compare the diagnostic performance of robotic arm-assisted [68Ga]Ga-PSMA-11 PET/CT-guided prostate biopsy (PGPB) with mpMRI-directed cognitive-fusion transrectal ultrasound-guided biopsy (MCFB) in biopsy-na&#xef;ve men with clinical findings suggestive of PCa. Methods: This prospective, single-center, randomized clinical trial (NCT05137561) enrolled biopsy-na&#xef;ve men age 50-90 y with elevated levels of prostate-specific antigen (&#x2265;4 ng/mL) and abnormal digital rectal examination findings. All participants underwent mpMRI, and those with a PI-RADS score of 4 or greater were randomized into 2 arms. In arm 1, participants underwent PGPB for a [68Ga]Ga-PSMA-avid lesion, and participants in arm 2 underwent MCFB. Participants in arm 1 with PET-negative findings subsequently underwent MCFB, and participants with negative biopsy results underwent PET and PGPB. The primary outcome was the detection of PCa. Secondary outcomes included complication rates and participant-reported pain. Result: Of the 267 participants enrolled, 81.3% (217) had lesions with a PI-RADS score of 4 or greater and were randomized to either PGPB (n = 112) or MCFB (n = 105). PCa was detected in 97.1% of participants (101/104) in arm 1 and 81.0% (85/105) in arm 2 (P < 0.05). PGPB showed higher diagnostic accuracy for PI-RADS 5 lesions (100% vs. 95.1%, P = 0.09). Major complications were observed in arm 2 only (n = 5). Arm 1 had significantly fewer complications (10.8% vs. 51.4%, P < 0.01), a lower median visual analog scale score for pain (3 vs. 5), and shorter procedure times. The core positivity rate was higher in arm 1 (60% &#xb1; 20%), despite obtaining fewer cores. Conclusion: [68Ga]Ga-PSMA-11 PGPB demonstrated higher diagnostic performance, fewer complications, and better tolerability compared with MCFB. This approach enables integrated diagnosis and staging, offering a promising alternative for efficient, safe, and accurate evaluation of prostate cancer.

Humans

Liquid biopsy-based detection of circulating and exfoliated cholangiocarcinoma tumor cells from blood and bile using heparan sulfate octasaccharides on integrated microfluidic systems.

Early diagnosis of cholangiocarcinoma (CCA) remains challenging because existing diagnostic approaches often lack sufficient sensitivity for reliable detection of early-stage disease. Circulating tumor cells (CTCs) in blood and exfoliated tumor cells (ETCs) in bile represent valuable targets for liquid biopsy-based detection; however, their low abundance and the complexity of clinical sample analysis pose substantial technical challenges for reliable enrichment and identification. Herein, we present a reproducible workflow for isolating and identifying CCA tumor cells from blood for CTCs and bile for ETCs using synthetic cell-surface heparan sulfate (HS) octasaccharide-functionalized magnetic beads (MBs) on integrated microfluidic systems. The method combined sample pre-processing, magnetic bead-based enrichment, controlled low-shear mixing and immunofluorescence-based identification into a unified workflow compatible with distinct clinical sample types. Key operational parameters, including MB concentration, mixing frequency, and pressure settings, were detailed to facilitate consistent performance. Using this workflow, tumor cell capture rates of approximately 70% in bile (for ETCs) and blood (for CTCs) were achieved, with a total processing time of 60-90&#xa0;min per sample under clinically relevant low-abundance conditions. The platform enables reliable detection of as few as 1 tumor cell per mL of blood or bile. This method provides a practical and adaptable strategy for glycosaminoglycan-mediated liquid biopsy applications and may be extended to other tumor-cell enrichment workflows involving heterogeneous cell-surface interactions.

Humans

Characteristics of p53 and Smad4 immunohistochemistry in pancreatic ductal adenocarcinoma and validation by next-generation sequencing.

BACKGROUND: Mutations in four major driver genes -KRAS, CDKN2A, TP53, and SMAD4- are central to the pathogenesis of pancreatic ductal adenocarcinoma (PDAC) and critically inform diagnosis, therapeutic decision-making, and prognostic assessment. Although next-generation sequencing (NGS) is widely regarded as the gold standard for detecting these mutations, its clinical application is often limited by suboptimal analytical efficiency and substantial economic cost. Among these genes, immunohistochemical (IHC) staining for the proteins encoded by TP53 and SMAD4 has been extensively adopted in routine pathology practice. However, standardized IHC pattern classification schemes and rigorous validation of their predictive accuracy for underlying genomic alterations remain lacking in PDAC. METHODS: We retrospectively enrolled 63 PDAC patients and systematically characterized the typical IHC expression patterns of p53 and Smad4. Targeted NGS was subsequently performed on all available tumor specimens, and the resulting mutational profiles were correlated with corresponding IHC findings. Diagnostic performance including sensitivity, specificity and accuracy of p53 IHC for predicting TP53 mutations and of Smad4 IHC for predicting SMAD4 mutations was rigorously evaluated. RESULTS: Among the four canonical driver genes, co-occurring double- or triple-gene mutations were prevalent; within TP53 and SMAD4, missense mutations constituted the most frequent variant type. Using NGS as the reference standard, we validated the diagnostic utility of a three-tiered p53 IHC classification system, particularly in fine-needle biopsy (FNB) specimens. Furthermore, we proposed a novel, refined Smad4 IHC pattern classification that incorporates an "intermediate" category, thereby expanding upon conventional binary interpretation. This new scheme achieved markedly improved mutation prediction accuracy (0.76) compared with traditional approaches (0.57). CONCLUSION: Our study highlights the complementary diagnostic value of p53 and Smad4 IHC relative to molecular testing in PDAC, especially when tissue is limited, as commonly encountered in FNB specimens. The newly established Smad4 IHC classification system, which integrates an intermediate expression category into the conventional two-tier framework, demonstrates superior clinical utility and enhances predictive accuracy for SMAD4 genomic alterations.

Humans

Use of indocyanine green fluorescence versus patent blue V dye for sentinel lymph node biopsy in early breast cancer, a randomized controlled trial.

BACKGROUND: Sentinel lymph node biopsy (SLNB) is standard for axillary staging in early breast cancer. While the combination of radioisotope and blue dye (e.g., patent blue V, PBV) remains the standard, it has limitations including logistics, variable identification rate (IR), and allergic potential. Indocyanine green (ICG) fluorescence is a promising alternative, but high-quality comparative evidence is needed. METHODS: This was a single-center, prospective, randomized controlled trial. Forty patients with early-stage, node-negative breast cancer were allocated to SLNB using either ICG (n&#x2009;=&#x2009;20) or PBV (n&#x2009;=&#x2009;20). All patients subsequently underwent completion level I-II axillary lymph node dissection (ALND) as the pathological reference standard for diagnostic performance assessment. Primary outcome was sentinel lymph node (SLN) IR. Secondary outcomes included detection time, number of SLNs retrieved, false-negative rate (FNR), and safety. RESULTS: Baseline characteristics were comparable between groups. The SLN IR was significantly higher with ICG (100% [20/20]) than with PBV (75% [15/20], p&#x2009;=&#x2009;0.047). ICG was associated with a significantly shorter median detection time (14.5 vs. 24.0&#xa0;min, p&#x2009;<&#x2009;0.001) and retrieved more SLNs (mean: 3.6 vs. 2.4, p&#x2009;=&#x2009;0.002). Most critically, ICG demonstrated 100% sensitivity, specificity, negative predictive value (NPV), and overall diagnostic accuracy, with a 0% FNR. In contrast, PBV achieved a sensitivity of 75%, an overall diagnostic accuracy of 90%, and an FNR of 25%. No ICG-related adverse events occurred. PBV caused skin discoloration in 75% of patients and one (5%) allergic reaction. CONCLUSION: ICG fluorescence achieved a higher SLN IR, shorter detection time, higher sensitivity, lower FNR, and fewer tracer-related adverse events than PBV as a single tracer for SLNB in patients with early-stage breast cancer. These findings suggest that ICG is a promising standalone tracer when radioisotope mapping is unavailable. Larger multicenter studies are required before widespread adoption can be recommended.

Humans

Integrated morphologic, immunophenotypic, and molecular profiling of advanced upper tract urothelial carcinoma across tumor compartments supports biopsy-based testing.

Upper tract urothelial carcinoma (UTUC) is an aggressive malignancy with limited molecular characterization in advanced disease. FGFR3 alterations are well established in low-grade urothelial carcinoma, but their prevalence, stability, and biological significance in locally advanced and metastatic UTUC remain only partially defined. We performed an integrated morphologic, immunohistochemical, and molecular analysis of 24 locally advanced and/or metastatic UTUC from 20 patients. FGFR3 status was assessed by RT-PCR across multiple tumor compartments, including biopsies, primary tumors, lymph-node metastases, and distant metastatic sites. Immunohistochemistry included CK20, CK5, GATA3, p53, and mismatch repair proteins. Targeted next-generation sequencing (NGS) was used to characterize co-occurring genomic alterations and to assess concordance with p53 immunophenotype. FGFR3 alterations were identified in 50% of patients and in 54.2% of analyzed tumors. FGFR3 status showed high intra-patient stability, with concordance between primary tumors and distant metastases in 90% of cases, whereas concordance with lymph node metastases was lower (50%), suggesting site-specific clonal divergence. Despite advanced stage, 92.3% of FGFR3-altered tumors displayed papillary urothelial carcinoma morphology, and most showed a luminal immunophenotype (61.5% by CK20/CK5 and 69.2% by GATA3/CK5). Targeted NGS revealed additional pathogenic alterations in 75% of patients, most frequently involving RTK/RAS/MAPK signaling (70%), cell-cycle regulation (25%), and PI3K/AKT pathway components (10%). TP53 mutations co-occurred with FGFR3 alterations in 60% of FGFR3-mutated patients and showed 90.4% concordance with p53 immunohistochemistry. Finally, a few cases exhibited complex, multi-site FGFR3 mutational patterns, consistent with intratumoral clonal evolutions. In conclusion, FGFR3 alterations are frequent and remarkably stable in advanced UTUC, even in high-grade and metastatic disease. These findings support the reliability of FGFR3 testing on limited diagnostic material and reinforce its relevance for therapeutic stratification. UTUC emerges as a molecularly dynamic disease in which early oncogenic drivers such as FGFR3 continue to shape tumor biology and therapeutic vulnerability at advanced stages.

Humans

"Everybody thinks that it won't happen to them": A mixed-methods study of HIV prevention strategies among people experiencing homelessness who use drugs.

BACKGROUND: HIV disproportionately affects people experiencing homelessness, particularly those who use drugs. Although effective prevention strategies exist, uptake remains suboptimal in high-risk populations. Limited research has examined how this population engages with HIV prevention strategies and the contextual factors shaping behaviors. METHODS: We conducted a mixed-methods study of adults (&#x2265;18 years) experiencing homelessness with recent drug use, recruited from three Boston sites (Feb 2024-Jan 2025). Participants completed a survey assessing HIV prevention strategy uptake. A subsample completed in-depth interviews on factors influencing behavior. Guided by the Theoretical Domains Framework, we coded qualitative data and identified themes to help contextualize uptake. RESULTS: Among 196 participants, mean age was 48; 61% identified as male and 44% as non-Hispanic White. Forty-two percent reported condomless sex, and among those who had ever injected drugs (n = 123), 24% reported syringe sharing in the prior three months. Only 9% reported current PrEP use, and 12% had ever used HIV self-tests. Qualitative findings highlighted perceived control as a key facilitator, while low perceived HIV risk hindered uptake across strategies. Additional barriers varied by strategy and included partner dynamics and substance use affecting condom use, structural constraints affecting syringe use, and knowledge, stigma, and cost concerns affecting PrEP and self-testing. CONCLUSION: In this cohort of people experiencing homelessness who use drugs, HIV prevention strategy uptake was suboptimal, with particularly low PrEP and HIV self-testing use. Qualitative findings suggest that interventions to promote HIV prevention strategy uptake in this population should leverage perceived control, address perceived risk, and target strategy-specific interpersonal and structural barriers.

Humans

Fractional laser therapy versus microneedling for non-acne scars and scar-like dermal fibrotic lesions.

BACKGROUND: Scarring caused by trauma, burns, surgery, and other dermal fibrotic conditions can lead to functional limitation and cosmetic distress. The comparative effectiveness of fractional laser therapy and microneedling for non-acne scars remains uncertain. METHODS: We conducted a systematic review and meta-analysis of randomized controlled trials comparing fractional laser therapy with microneedling for non-acne scars and scar-like dermal fibrotic lesions. Following a PROSPERO-registered protocol and PRISMA guidelines, we searched PubMed, EMBASE, Web of Science, Cochrane Library, and CNKI from inception to May 2026 without language restrictions. Parallel-group and split-body randomized trials were eligible. Random-effects models were used to calculate standardized mean differences (SMDs) for continuous outcomes and odds ratios (ORs) for dichotomous outcomes. RESULTS: Nine randomized controlled trials were included. Fractional laser therapy showed a statistically significant advantage over microneedling in scar scores (SMD = -0.99, 95% CI [-1.83, -0.15], P&#x2009;=&#x2009;0.02) and collagen fiber regeneration (SMD = -2.14, 95% CI [-3.57, -0.72], P&#x2009;=&#x2009;0.03). No statistically significant differences were found between the two interventions for elastic fiber improvement, epidermal thickness, or adverse events. Subgroup analyses did not show clear or consistent significant differences according to laser type, including comparisons between traditional and non-traditional fractional lasers and between CO&#x2082; and non-CO&#x2082; fractional laser systems. Substantial heterogeneity was observed across several outcomes, indicating considerable between-study variability. CONCLUSION: Based on currently available randomized evidence, fractional laser therapy may provide superior improvement in overall scar severity and collagen fiber regeneration compared with microneedling for non-acne scars and scar-like dermal fibrotic lesions. However, no clear differences were observed for elastic fiber improvement, epidermal thickness, or adverse-event incidence. Given the substantial heterogeneity, limited sample sizes, and possible reporting bias, these findings should be interpreted cautiously. Further large, standardized trials with longer follow-up are needed.

Humans