Search PubMedSearch

SEARCH · Search PubMed

Results for “Prefilled syringe with needle safety device”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,685 recordsLinked to original sources

Phase 1 Study Evaluating Gefurulimab Pharmacokinetics and Safety Following Delivery Via Autoinjector or Prefilled Syringe With Needle Safety Device in Healthy Adults.

PURPOSE: Gefurulimab, a novel dual-binding nanobody targeting complement component 5 (C5), is in clinical development for anti-acetylcholine receptor antibody-positive generalized myasthenia gravis. Gefurulimab has a low molecular weight, enabling subcutaneous (SC) self-administration by autoinjector (AI) or prefilled syringe with needle safety device (PFS-SD). We compared gefurulimab pharmacokinetic (PK) exposure and safety in healthy adults following a single SC dose administered by AI versus PFS-SD. METHODS: In this phase 1, open-label, randomized, parallel-group study (NCT06208488), healthy participants aged 18 to 65 years were stratified by weight and randomized equally to 1 of 6 combination groups of device and injection site (abdomen/thigh/upper arm). Participants received a single SC dose of gefurulimab on day 1 and were assessed throughout the 92-day evaluation period. Primary endpoints were PK parameters for each device: maximum observed concentration (Cmax) and area under the serum concentration-time curve (AUCinf, AUClast). PK across injection sites, pharmacodynamics, safety, immunogenicity, and device performance were also assessed. FINDINGS: Overall, 175 participants were randomized: AI (n = 87), PFS-SD (n = 88). Geometric least squares mean ratios (90% CI) comparing AI/PFS-SD for Cmax, AUCinf, and AUClast were 97.6% (94.5-100.8), 99.6% (96.1-103.3), and 98.8% (95.2‒102.6), respectively. Secondary analyses found no meaningful differences in PK parameters across injection sites. Serum-free C5 concentrations over time, treatment-emergent adverse event (TEAE) profiles, and antidrug antibody responses were similar between cohorts. Most TEAEs were mild; none led to study discontinuation. IMPLICATIONS: SC administration of gefurulimab by AI and PFS-SD was well tolerated with comparable exposure, meeting bioequivalence criteria.

Humans

Analyzing the impact of subcutaneous injection needle, device, and administration characteristics on patient pain, anxiety, and safety: a systematic literature review.

The subcutaneous (SC) injection route is a commonly used and important method for therapeutic delivery of a wide range of compounds, and needle characteristics have a significant influence on patient pain, anxiety, safety, and other outcomes. This systematic review evaluates the evidence on how needle-specific characteristics (e.g. gauge, length, tip design, wall thickness, concealment) and administration- or device-related factors can affect patient-reported outcomes and clinical safety indicators during and following SC injections. A comprehensive search was conducted in MEDLINE, PubMed, Embase, and ClinicalTrials.gov in June 2024. Studies were included if they assessed the relationship between needle characteristics and pain, anxiety, safety, or related outcomes in individuals receiving SC injections. A dual-reviewer process was used for study selection, data extraction, and quality assessment. Sixty-two studies met inclusion criteria. Evidence consistently indicated that thinner and shorter needles reduced patient-reported pain and adverse events such as bruising and bleeding. Tapered and lubricated needles, hidden or retractable needle designs, and use of autoinjectors or prefilled syringes also contributed to reduced anxiety and improved user satisfaction. However, results were heterogeneous, and many studies lacked sufficient power or single-variable evaluation of individual needle parameters, limiting definitive conclusions. Needle characteristics significantly influence patient experience and safety with SC delivery. While both clinical evidence and practical experience clearly favor thinner, shorter, and concealed needles, further standardized, high-quality research is needed to isolate and quantify the specific contributions of individual needle characteristics to optimize injection practices and support patient-centered device design.

Humans

"It was good because they have a relationship with us": A qualitative study on low-threshold buprenorphine treatment at syringe services programs.

INTRODUCTION: Syringe service programs (SSPs) reach people who inject drugs with opioid use disorder (OUD) and are novel "low-threshold" venues to initiate buprenorphine treatment. The study investigated patients' experiences with SSP-initiated buprenorphine treatment, which could aid in improving buprenorphine treatment delivery at SSPs. METHODS: The study included 12 participants who completed qualitative exit interviews after a randomized controlled trial of buprenorphine treatment at SSPs. In the parent study, participants received buprenorphine treatment through an onsite model at an SSP or enhanced referral to a community health center based on the randomization sequence. Most participants started taking buprenorphine at home. Exit interviews included participants from both study arms, and the semi-structured interview guide focused on their experiences with clinicians, experiences initiating buprenorphine, prior experiences with OUD treatment, and perceptions about continuing buprenorphine treatment. Four researchers iteratively read, coded, and discussed each transcript, then they derived recurring themes using thematic analysis. RESULTS: Participants were mostly male, middle-aged, and 50% identified as Latino. Four main themes related to buprenorphine treatment initiation: 1) Onsite treatment facilitated buprenorphine prescription, but some participants also expressed a need for additional support; 2) Precipitated withdrawal complicated participants' buprenorphine initiation in both arms; 3) Participants largely experienced the SSPs as affirming and welcoming; and 4) Developing strong relationships with healthcare providers was critical to successful buprenorphine treatment initiation. CONCLUSIONS: The SSP-based model provided rapid access to buprenorphine prescriptions, but precipitated withdrawal was a common complication. Some participants desired additional support and guidance when they started taking buprenorphine at home. The findings point to a "low-threshold, high-touch" approach where participants receive expedited access to buprenorphine providers at SSPs but also additional support throughout the initiation process to avoid and/or manage precipitated withdrawal. Despite some challenges, SSP-based buprenorphine treatment was highly valued by study participants.

Humans

Risk factors and management strategies for needle disengagement from the visual field in pediatric robot-assisted laparoscopic pyeloplasty.

OBJECTIVE: This study aimed to identify risk factors for suture needle disengagement from the visual field during pediatric robot-assisted laparoscopic pyeloplasty (RALP) and propose effective strategies for prevention and management. METHODS: A retrospective cohort study analyzed clinical data from 339 pediatric patients who underwent RALP for ureteropelvic junction obstruction (UPJO) at a single institution between August 2017 and December 2020. Patients were categorized based on the occurrence of needle disengagement from the visual field. Various patient demographics and surgical procedural factors were evaluated. Univariate and multivariate logistic regression, along with LASSO regression, identified independent risk and protective factors. RESULTS: Needle disengagement occurred in 38 (11.21%) of 339 cases. Multivariate logistic regression identified five independent risk factors for needle disengagement: use of a 3-mm auxiliary trocar (OR = 4.69, 95% CI: 1.98-12.53, P < 0.001), non-standard needle holder use (OR = 2.32, 95% CI: 1.04-5.18, P = 0.038), unshaped suture needles (OR = 3.16, 95% CI: 1.44-7.19, P = 0.005), simultaneous use of &#x2265;2 intra-abdominal sutures (OR = 2.46, 95% CI: 1.15-5.48, P = 0.023), and clamping the needle shank during withdrawal (OR = 3.42, 95% CI: 1.40-8.21, P = 0.006). Conversely, sufficient assistant experience (>10 cases) was identified as a protective factor (OR = 0.39, 95% CI: 0.18-0.88, P = 0.021). CONCLUSION: Suture needle disengagement from the visual field during pediatric RALP is associated with specific technical and instrumental factors. Implementing targeted strategies-such as mandating specialized needle holders, preoperative needle shaping, a single-needle workflow, prioritizing clamping the suture thread over the needle shank during withdrawal, and ensuring adequate assistant training-has the potential to significantly reduce significantly mitigate the risk of needle loss and enhance overall surgical safety in pediatric RALP.

Humans

Cryostick pre-cooling reduces pain during intra-articular knee injections: a randomized, contralateral-controlled trial.

BACKGROUND: Intra-articular knee injections are essential for osteoarthritis management but often limited by "needle phobia" and procedural pain. The cryostick, a high-thermal-conductivity device, is a potential analgesic; however, evidence regarding its efficacy in reducing pain and bleeding is limited. The purpose of the study was to evaluate whether cryostick application reduces procedural pain, reduces bleeding, and improves patient satisfaction during intra-articular knee injections. METHODS: This randomized, contralateral-controlled trial included 50 patients (100 knees) with bilateral knee osteoarthritis. One knee received a 20-s cryostick protocol (-20&#xb0;C) immediately before injection; the contralateral knee received a standard injection. Primary outcome was pain intensity (100-mm VAS) during needle penetration and at 5-min post-injection. Secondary outcomes included bleeding area (mm2) and satisfaction (1-5 Likert scale). RESULTS: Cryostick application significantly reduced pain during needle penetration (Mean Difference [MD] -24.8&#xa0;mm; 95% CI -29.9 to -19.7; P&#xa0;<&#xa0;0.001) and at 5-min post-injection (MD -20.8&#xa0;mm; 95% CI -26.8 to -14.8; P&#xa0;<&#xa0;0.001). The Number Needed to Treat (NNT) to achieve the Minimal Clinically Important Difference (13&#xa0;mm) was 1.28 (95% CI 1.15-1.54) during penetration and 1.79 (95% CI 1.45-2.36) at 5-min post-injection. The bleeding area was significantly smaller with cryostick (MD -4.82&#xa0;mm2; P&#xa0;=&#xa0;0.014). Patients reported significantly higher satisfaction scores with the cryostick (4.10 vs 2.96; P&#xa0;<&#xa0;0.001). CONCLUSIONS: A 20-s cryostick application is a safe, well-tolerated, and effective adjunct for attenuating pain and bleeding during knee injections. This technically simple approach requires minimal complexity, offering an efficient, non-pharmacological tool to enhance patient comfort.

Humans

Complication rates of 16- and 18-gauge needles for native kidney biopsies: a systematic review and proportional meta-analysis.

This systematic review and meta-analysis evaluated complication rates and diagnostic yield reported in studies of adult native kidney biopsy using 16-gauge (16&#x2009;G) or 18-gauge (18&#x2009;G) needles. We included randomized trials and cohort studies of real-time ultrasound-guided biopsies, including case series. MEDLINE, Embase, and CENTRAL were searched through October 2024. Two reviewers independently performed study selection, data extraction, and risk of bias assessment using Joanna Briggs Institute tools. Random-effects meta-analyses estimated pooled proportions with 95% confidence intervals (CI), and univariable random-effects meta-regression explored study-level associations with major complications, transfusion, or gross hematuria. We screened 4,499 titles and abstracts and reviewed 319 full-text articles; 62 studies comprising 68 biopsy series were included. The pooled major complication rate in studies using 16&#x2009;G needles was 1.83% (95% CI: 1.20-2.79) and 1.29% (95% CI: 0.78-2.13) in studies using 18&#x2009;G needles, with no statistically significant difference. Mean glomerular yield was 18.8 with 16&#x2009;G and 17.5 with 18&#x2009;G needles. In study-level meta-regression, studies with higher prevalence of acute kidney injury, lower mean estimated glomerular filtration rate, or lower mean hemoglobin reported higher pooled complication rates. Most studies were single-arm cohorts; between-needle differences therefore reflect indirect study-level contrasts. Interpretation is limited by retrospective design and heterogeneity across studies. Overall, studies using both needle sizes reported low complication rates and similar diagnostic yield, although definitions and reporting varied. Direct comparative studies are needed to determine whether meaningful differences exist.

Humans

Glaucoma filtering surgery combined with phacoemulsification in the era of new aqueous humor filtration devices: A systematic review.

We evaluate the efficacy and safety of filtering glaucoma surgeries combined with phacoemulsification (PCE)-including new aqueous humor drainage devices-compared to standalone procedures. We performed a systematic search up to March 23, 2025, including all comparative studies assessing trabeculectomy (TRAB), non-penetrating deep sclerectomy (NPDS), Xen&#xae; Gel Stent (XEN), or Preserflo&#xae; MicroShunt (PMS) combined with PCE, versus the same surgery alone. Key exclusion criteria include inadequate follow-up (less than 12-month), absence of a defined success criterion, more than 50% of loss to follow-up at 12-month, and lens extraction performed without PCE. Main outcome was surgical success at &#x2265;&#x202f;12 months. Secondary outcomes included intraocular pressure (IOP) reduction, decrease in hypotensive medications, and rates of complications. A total of 27 studies were included for analysis. Among studies comparing TRAB/PCE with standalone TRAB, half reported similar success rates, while others favored standalone TRAB, particularly using strict IOP thresholds. Safety profiles were comparable. For NPDS/PCE, data mostly showed equivalent outcomes versus standalone NPDS, with comparable safety. In studies on XEN/PCE and PMS/PCE, results suggested similar rates of surgical success, efficacy in IOP and medication reduction, and safety compared to their stand-alone procedures. Small differences occasionally favored standalone procedures under stricter success definitions. Current evidence suggests that combined filtering glaucoma surgery provides long-term efficacy and safety comparable to standalone, though some subgroups and outcome thresholds may slightly favor standalone approaches. The limited availability of high-quality prospective trials underscores the need for further large-scale robust studies.

Humans

Hydrodissection-assisted laparoscopic orchiopexy utilizing needle grasper for palpable undescended testes: Clinical efficacy analysis.

OBJECTIVE: Laparoscopic orchiopexy has emerged as a viable alternative for the treatment of palpable undescended testis (UDT). This study aims to evaluate the feasibility and efficacy of needle-grasper hydrodissection-assisted laparoscopic orchiopexy (NHLO) in comparison to conventional laparoscopic orchiopexy (CLO) for palpable UDT. METHODS: A cohort of 96 patients diagnosed with palpable UDT, admitted between January 2020 and April 2024, was included in this study. Among these, 54 patients underwent NHLO, while 42 patients were treated with CLO. In the NHLO procedure, normal saline was injected into the retroperitoneal space to create a hydrodissection barrier, facilitating the separation and protection of the vas deferens and spermatic cord. The vas deferens and spermatic cord were meticulously dissected following the principles of integrity and minimal tissue trauma. Outcome measures included final testicular position, testicular volume growth, testicular atrophy, success rate, and postoperative complications. RESULTS: No significant differences were observed between the NHLO and CLO groups in terms of age, laterality, operative time (NHLO: 38-46 min; CLO: 39-48 min), or complication rates (NHLO: 1.9 %; CLO: 0.0 %). At follow-up, all patients in both groups exhibited palpable testes in satisfactory scrotal positions. Notably, no visible abdominal scarring was observed in the NHLO group, whereas there were two noticeable scars on the abdomen in CLO. CONCLUSION: Needle-grasper hydrodissection-assisted laparoscopic orchiopexy is a safe, effective, and minimally invasive technique that provides optimal protection of the vas deferens and spermatic cord while achieving excellent cosmetic outcomes.

Humans

Prostate morcellation devices: a systematic review and meta-analysis of clinical outcomes and efficiency.

OBJECTIVE: To systematically evaluate the efficiency and safety of different prostate morcellators used during prostate enucleation for benign prostatic hyperplasia (BPH). METHODS: A systematic review was performed according to the Preferred Reporting Items for Systematic Review and Meta-analyses guidelines. PubMed/Medline, Scopus, and Web of Science were searched for studies published between October 2012 and May 2025. Studies reporting clinical outcomes of morcellators used during prostate enucleation were included. Primary outcome was morcellation efficiency (g/min). Secondary outcomes included intraoperative complications, device malfunction, and cost when available. Risk of bias (RoB) was assessed using the Risk Of Bias In Non-randomised Studies of Interventions (ROBINS-I), RoB 2 tool, and European Association of Urology case-series criteria. Random-effects meta-analyses and multilevel meta-regression adjusted for prostate volume were conducted. RESULTS: A total of 22 studies comprising 5980 patients were included, most undergoing holmium laser enucleation of the prostate. The most frequently evaluated devices were the Piranha&#x2122; (Richard Wolf GmbH, Knittlingen, Germany) and Lumenis VersaCut&#x2122; (Lumenis Ltd., Yokneam, Israel; 12 and 13 studies, respectively), followed by DrillCut&#x2122; (Karl Storz SE & Co. KG, Tuttlingen, Germany), MultiCut&#x2122; (Asclepion Laser Technologies GmbH, Jena, Germany), and Cyber Blade&#x2122; (Quanta System SpA, Milan, Italy) systems. Unadjusted weighted mean morcellation efficiency was 7.80&#x2009;g/min (95% confidence interval [CI] 6.26-9.34&#x2009;g/min) for Piranha, 4.70&#x2009;g/min (95% CI 3.61-5.79&#x2009;g/min) for VersaCut, 5.90&#x2009;g/min (95% CI 3.16-8.64&#x2009;g/min) for DrillCut, and 9.59&#x2009;g/min (95% CI 4.78-14.39&#x2009;g/min) for MultiCut. In volume-adjusted meta-regression using Piranha as reference, VersaCut remained significantly less efficient (-2.75&#x2009;g/min; 95% CI -4.58 to -0.92&#x2009;g/min; P&#x2009;=&#x2009;0.003), with an even greater difference in prostates >70&#x2009;mL (-4.34&#x2009;g/min). Bladder mucosal injury was the most frequently reported complication; however, relatively rare across all devices. Meta-analysis demonstrated a significantly higher risk with VersaCut compared to Piranha (risk ratio 3.22, 95% CI 1.81-5.71), with low heterogeneity. CONCLUSION: This systematic review provides a contemporary clinical benchmark of the efficiency and safety of currently available prostate morcellators. Oscillating blade systems, particularly the Piranha morcellator, demonstrated higher morcellation efficiency and a more favourable safety profile than reciprocating blade devices, with the largest performance differences observed in patients with larger prostates.

Humans

Prothrombin complex concentrate (PCC) vs. non-PCC strategies for warfarin reversal in left ventricular assist device recipients: A systematic review and meta-analysis.

BACKGROUND: Left ventricular assist devices (LVADs) prolong survival in end-stage heart failure, and warfarin thromboprophylaxis is recommended to prevent device thrombosis and thromboembolic complications. When bleeding occurs or emergency surgery is required, rapid anticoagulation reversal is critical. Prothrombin complex concentrate (PCC) provides rapid reversal; however, its risk-benefit profile in LVAD recipients remains unclear. We conducted a systematic review and meta-analysis comparing PCC with non-PCC strategies for warfarin reversal in LVAD recipients. METHODS: MEDLINE, Embase, and Scopus were searched through June 2025 for studies of PCC versus non-PCC strategies for warfarin reversal in LVAD recipients. Two reviewers independently extracted data. Random-effects models were used to pool arm-level estimates and to pool head-to-head comparisons using mean differences or risk ratios (RRs). RESULTS: Eighteen studies involving 779 patients were included. Arm-level pooled estimates for PCC versus non-PCC comparators were 24.0% versus 15.8% for mortality, 16.5% versus 12.1% for thrombotic events, and 3.1 versus 5.7 for FFP units. Arm-level time to INR correction was longer with PCC overall (16.5 versus 13.6&#xa0;h), driven by one elective cohort, but faster within the ICH subgroup (6.0 versus 13.7&#xa0;h). In head-to-head comparisons, PCC achieved faster INR correction than non-PCC comparators (mean difference&#xa0;-&#xa0;7.6&#xa0;h; p&#xa0;=&#xa0;0.001) and required fewer FFP units (-2.6&#xa0;units; p&#xa0;=&#xa0;0.019), with no significant difference in all-cause mortality (RR 1.14; p&#xa0;=&#xa0;0.490) or thrombotic events (RR 1.43; p&#xa0;=&#xa0;0.176). CONCLUSIONS: In head-to-head studies, PCC was associated with faster INR correction and lower FFP requirements than non-PCC strategies, whereas mortality and thrombotic events did not differ significantly. Given the observational evidence, wide confidence intervals, and heterogeneity, equivalent safety cannot be established, and prospective studies are needed to define the relative safety and effectiveness of the two approaches. IMPLICATIONS FOR CLINICAL PRACTICE: PCC-based strategies may be considered for urgent warfarin reversal in LVAD recipients, particularly when rapid INR reduction or avoidance of large-volume plasma transfusion is clinically important. Treatment decisions should account for the indication, bleeding severity, and underlying thrombotic risk. TRIAL REGISTRATION: CRD42024573925.

Humans

Primary pulmonary salivary gland-type tumors in cytopathology practice: A systematic review and meta-analysis.

BACKGROUND: Primary pulmonary salivary gland-type tumors (PSGTs) are rare but clinically significant tumors that originate from the submucosal glands of the tracheobronchial tree. Cytologic samples taken during bronchoscopy are a key component of preoperative evaluation. However, cytologic diagnosis remains challenging because of the submucosal growth and morphologic overlap of PSGTs. In addition, current knowledge of the cytohistologic correlation of PSGTs is fragmented. The objective of this study was to assess the effectiveness of cytologic diagnoses of PSGTs. METHODS: A comprehensive, systematic literature search of the PubMed database was conducted to identify studies with cytologic and histologic diagnoses of PSGTs. Comprehensive data on diagnostic and clinical factors, when available, were collected for all individual patients. The data were tabulated in Microsoft Excel and analyzed using OpenMeta (Analyst) software. RESULTS: In total, 49 studies comprising 106 patients were identified. Final cytohistologic concordance was demonstrated in 48.1% of cases. Fine-needle aspiration showed the highest sensitivity (75.0%), followed by bronchial/tracheal washing (38.1%), and bronchial brushing (34.2%). Adenoid cystic carcinoma was the most common histologic subtype, accounting for 67 cases, followed by mucoepidermoid carcinoma, which accounted for 27 cases. CONCLUSIONS: The cytologic diagnosis of rare PSGTs remains challenging. Overall, cytohistologic concordance was 48.1%. However, fine-needle aspiration demonstrated greater diagnostic accuracy than exfoliative cytology and may facilitate a more accurate preoperative assessment.

Humans

Intraocular Pressure Changes Following Intraluminal Stent Removal From the Paul Glaucoma Implant: A Systematic Review and Meta-Analysis.

PURPOSE: This study aims to systematically review and perform a single-arm meta-analysis to comprehensively evaluate the effect of removal of intraluminal stent from the Paul glaucoma implant (PGI) on intraocular pressure (IOP) changes and to summarize its long-term efficacy and safety. CLINICAL RELEVANCE: Glaucoma remains one of the leading global causes of irreversible vision loss, necessitating effective surgical management for refractory cases. Glaucoma drainage devices are critical for these complex forms, and intraluminal stent removal from the PGI serves as a key strategy to titrate aqueous outflow and optimize long-term IOP control. METHODS: A systematic review was conducted by searching EMBASE, Medline, and CENTRAL. The meta-analysis ultimately included 5 observational studies. The Risk of Bias in Nonrandomized Studies of Interventions (ROBINS-I) tool was used to assess the quality of the included studies. Continuous outcomes (eg, postremoval stent IOP reduction) were analyzed using the mean difference (MD) with 95% confidence intervals (CI); dichotomous outcomes (eg, hypotony incidence) were evaluated using pooled proportion with 95% CI. All meta-analyses employed a random-effects model. RESULTS: Our meta-analysis included 5 studies, involving a total of 283 eyes. The meta-analysis revealed that removal of the stent leads to a significant and immediate IOP reduction. The IOP reduction (immediate postremoval stent IOP minus preremoval stent IOP) was significant, with a pooled MD of -9.09 mm Hg IOP (MD = 9.09; 95% CI = [-11.77, -6.41]). In the preremoval stent high-IOP (>21 mm Hg) subgroup, the IOP reduction is -11.82 (95% CI = [-10.14, -13.51]). This reduction was significantly greater than the preremoval stent low-IOP (<21 mm Hg) subgroup, whose reduction is -6.66 mm Hg (95% CI = [-5.55, -7.77]). Regarding safety, the pooled proportion of clinically hypotony was low and highly consistent (I&#xb2; = 0.00%) at only 0.03 (95% CI = [0.00, 0.15]). CONCLUSIONS: Intraluminal stent removal from the PGI is an effective and safe IOP-lowering intervention. Its IOP reduction effect is significantly more pronounced in patients with preremoval stent high IOP, providing crucial clinical guidance for managing persistently high IOP after PGI implantation.

Humans

Oxygen-controlled gamma-irradiation and annealing enable terminal processing of collagen-based biomaterials.

Gamma irradiation is a widely adopted method for terminal sterilization of medical devices; however, its application to collagen-based extracellular matrix (ECM) materials remains limited due to radiation-induced degradation of structural integrity and mechanical performance. Here, we present an engineered terminal-processing strategy that combines oxygen controlled gamma irradiation (25-30&#xa0;kGy) with post-irradiation dry-heat annealing to preserve ECM functionality while achieving effective sterilization. By modulating oxygen availability during irradiation, this approach alters radical reaction pathways, suppresses oxygen-mediated oxidative degradation, and generates a metastable radical-containing intermediate, which is subsequently converted into a structurally stabilized collagen network through thermal annealing. As a result, the treated matrices preserved ECM integrity and recovered clinically relevant mechanical properties. Furthermore, the process achieved cumulative viral reductions exceeding 6 log10 across a representative panel including enveloped and non-enveloped DNA and RNA viruses, demonstrating compatibility with sterility assurance and viral safety requirements for biologically derived medical devices. Notably, preliminary observations indicate that mechanical integrity can be partially preserved even at elevated irradiation doses up to 50&#xa0;kGy, suggesting potential applicability to sterilization validation frameworks requiring higher assurance levels. Overall, this work establishes a mechanistically grounded terminal-processing paradigm that enables control of radical fate, decouples sterilization efficacy from material degradation, and integrates sterilization, viral safety, and functional preservation into a unified and scalable framework for collagen-based biomaterials. This concept repositions gamma-irradiation from a purely degradative process to a controllable tool for tuning collagen structure and performance.

Gamma Rays

Effect of urinary catheter securement band on meatal pressure injury in male intensive care patients: A randomized controlled trial.

OBJECTIVES: To investigate the effectiveness of a urinary catheter securement band in preventing meatal pressure injury (meatal-PI) in male ICU patients, and to identify associated risk factors and the timing of injury development. METHODS: A total of 248 adult male ICU patients were randomly allocated to an intervention group (n&#xa0;=&#xa0;124) or a control group (n&#xa0;=&#xa0;124) between December 2024 and April 2025. The intervention group received a catheter securement band in addition to standard care, while the control group received standard care alone. Meatal-PI was evaluated daily using a structured monitoring form and a validated staging system. RESULTS: The incidence of meatal-PI was significantly lower in the intervention group (6.5%) compared with the control group (16.1%) (p&#xa0;=&#xa0;0.016). Multivariate analysis identified catheter securement, use of silicone catheters, higher Braden Scale scores, and shorter ICU length of stay as independent protective factors, while advanced age was associated with increased risk. Additional factors significantly associated with meatal-PI included comorbidities, higher device burden, latex catheter use, dry skin, lower Glasgow Coma Scale and Braden scores, sedation, and perineal oedema (p&#xa0;<&#xa0;0.001). CONCLUSIONS: The use of a catheter securement band significantly reduces the incidence of meatal-PI in male ICU patients. Incorporating catheter securement devices into routine nursing care, prioritising silicone catheter use, and performing regular meatal assessments may enhance patient safety by reducing the risk of device-related pressure injuries. Further research comparing different catheter securement methods across diverse patient populations is warranted. IMPLICATIONS FOR CLINICAL PRACTICE: The use of catheter securement bands may reduce the incidence of meatal-PI in male ICU patients. Incorporating standardized catheter stabilization strategies into routine intensive care nursing practice may enhance patient safety and support pressure injury prevention efforts.

Humans

Evaluation of one-step amplicon-based targeted enrichment for SARS-CoV-2 whole-genome sequencing using the Midnight amplicon scheme.

Genomic surveillance proved invaluable during the COVID-19 pandemic for tracking SARS-CoV-2 variants and guiding outbreak responses, underscoring the ongoing need to reduce whole-genome sequencing (WGS) costs and improve workflow efficiency to ensure accessibility in resource limited settings. Here, we evaluated a one-step reverse transcription polymerase chain reaction (RT-PCR) approach using the Midnight V2 primer scheme for targeted amplification of the SARS-CoV-2 genome, assessed its compatibility with Illumina sequencing, and compared its performance to a well-established two-step method. Initially, we determined optimal RT-PCR reaction conditions using the Midnight V2 primer panel for the one-step RT-PCR kit and scaled reaction volumes for both RT-PCR and library preparation. Clinical specimens (n&#x202f;=&#x202f;53) that had undergone routine WGS for surveillance purposes using the established two-step RT-PCR method were compared using the one-step RT-PCR assay. For samples with genome completeness greater than 70%, both methods gave comparable results with similar sequence coverage and 100% concordance for lineage assignment. Further investigation revealed a higher percentage of reads aligning to the SARS-CoV-2 genome with a greater depth of coverage using the one-step method compared to the two-step method. Finally, analysis of scaled one-step and library reaction volumes revealed significant cost savings for samples undergoing WGS. Overall, the results presented here verify the accuracy and reproducibility of one-step targeted amplification and offer an efficient and cost-effective workflow for routine SARS-CoV-2 genomic surveillance.

Humans

Effect of Music on Pain, Anxiety, and Satisfaction During Intrauterine Device Application: A Randomized Clinical Trial.

This randomized controlled trial aimed to determine the effect of music played during intrauterine device (IUD) insertion on perceived pain, state anxiety, and satisfaction levels. The study was conducted with 70 women who applied to a maternal and child health and family planning center and were randomly assigned to the intervention and control groups using simple randomization. Data were collected using a Demographic Information Form, the State-Trait Anxiety Inventory (STAI-I), and the Visual Analog Scale (VAS), as well as Bluetooth speakers and the musical piece Evgeny Grinko-Valse. Participants in the intervention group listened to music before and during the IUD insertion procedure, whereas the control group received routine care only. Data were analyzed using SPSS version 26 with appropriate descriptive and inferential statistical methods. Women in the music group had significantly lower perceived pain (p&#x2009;<&#x2009;0.001) and state anxiety levels during the procedure (p&#x2009;=&#x2009;0.022), and significantly higher satisfaction levels compared with the control group (p&#x2009;<&#x2009;0.001). In addition, post-procedure state anxiety levels were positively correlated with pain intensity experienced during and after the procedure (r&#x2009;=&#x2009;0.542 and r&#x2009;=&#x2009;0.496, respectively; p&#x2009;<&#x2009;0.001), and negatively correlated with procedural satisfaction (r&#x2009;=&#x2009;-0.652; p&#x2009;<&#x2009;0.001). These findings suggest that listening to music during IUD insertion may help reduce pain and anxiety while potentially enhancing patient satisfaction. Trial Registration: NCT06215183.

Humans

Assessment of Surgical Salvage Outcomes for Exposed Cranial Neuromodulating Devices.

OBJECTIVES: Implanted neuromodulating devices (NMDs) such as cochlear implants (CIs) and deep brain stimulators (DBSs) are commonly used in modern medicine. Rarely, complications arise post-operatively, including hardware exposure. Traditional teaching suggests that these devices require removal if exposed; however, surgical salvage is a high risk, high reward alternative. We review our single institution experience managing NMD exposure with surgical salvage. METHODS: Retrospective chart review was performed on individuals who had a NMD implanted and underwent an attempt at surgical salvage for exposure during the study period (January 01, 2021 through December 31, 2023). Study outcome success was defined as maintaining a functional NMD 1&#x2009;year after salvage was attempted. Surgical techniques associated with successful salvage were compared. RESULTS: Nine of 729 patients (1.2%) implanted with NMDs experienced hardware exposure during this 2-year study period. Nine subjects were referred for NMD salvage; however, only 6 of 9 subjects (66.7%, CI&#x2009;=&#x2009;3; DBS&#x2009;=&#x2009;3) underwent NMD salvage attempts. Four of the subjects had successful salvage demonstrated successful salvage with a functioning NMD and without wound healing concerns 1&#x2009;year after their salvage procedure. CONCLUSIONS: Classic teaching states that exposed NMDs require explantation. However, this approach necessarily imposes time without benefit from the NMD between explantation and reimplantation. Our experience demonstrates that surgical salvage can be a successful alternative for the majority (66.7%) of individuals.

Humans

Use of wearable technologies for physical activity promotion in older adults: A systematic review.

This systematic review, conducted according to PRISMA guidelines and registered in PROSPERO (CRD420251055299), examined the use of wearable technologies for promoting physical activity (PA) in adults aged 60 years and older. Searches across five databases (PubMed, Scopus, Web of Science, CINAHL, Cochrane) identified 2438 records, of which only six randomized controlled trials published between 2021 and 2025 met inclusion criteria, with sample sizes ranging from 36 to 551 participants and mean ages between 65 and 79 years. Given the small number of included studies, findings should be interpreted as preliminary. The studies ranged from the standalone use of commercial trackers (Fitbit, Polar, ActiGraph) to multicomponent interventions combining wearables with physiotherapist feedback, telephone counseling, web-based platforms, or interactive cognitive-motor training. Wearables used alone, as in the REACT trial, produced small or non-significant PA effects. In contrast, interventions integrating devices with personalized feedback, professional support, or digital platforms, such as PROMOTE and TASMANIA, were associated with more consistent improvements in PA, physical function, and cognitive outcomes. Multicomponent programs, such as PEER and ICMT, reported broader benefits, including cognition, balance, and reductions in sedentary behavior, though these findings derive from individual trials and require replication. Risk of bias, assessed with the Cochrane Risk of Bias tool version 2 (RoB 2.0), was rated as "some concerns" for five studies and low for only one, mainly due to gaps in randomization reporting, missing data, and lack of preregistration. Tentatively, and based on a very limited evidence base, wearables may have greater impact when embedded within broader behavioral systems, incorporating feedback, coaching, or interactive components, rather than when used in isolation as passive monitoring tools. Adherence and psychosocial outcomes appeared related to comfort and perceived usefulness among older adults, though larger and more robust trials are needed to confirm these patterns.

Humans