Search PubMedSearch

SEARCH · Search PubMed

Results for “Mandibular advancement device”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

177 recordsLinked to original sources

Treatment of OSA using mandibular advancement versus CPAP in improving cardiovascular health.

BACKGROUND: Obstructive sleep apnea is a significant risk factor for hypertension. We assessed the relative effectiveness of mandibular advancement device (MAD) versus continuous positive airway pressure (CPAP) in reducing 24 h ambulatory blood pressure (BP) and other health-related outcomes over 12 months. METHODS: In a randomized, non-inferiority trial, 321 participants with hypertension and increased cardiovascular risk were recruited for polysomnography. Of these, 220 with moderate-to-severe OSA (apnea-hypopnea index (AHI) &#x2265;15 events/hour) were randomized to MAD or CPAP (1:1). We report the final outcomes at the 12-month follow-up. RESULTS: A total of 180 participants (MAD: 89; CPAP: 91) completed the 12-month follow-up. Median usage for MAD and CPAP was 5.5 and 4.9 h per night, respectively. Compared to baseline, the 24 h mean arterial BP at 12 months decreased by 2.3 mmHg (P = 0.200) in the MAD group and by 1.0 mmHg (P = 0.999) in the CPAP group. The difference between-groups was -0.6 mmHg (95% confidence interval: -2.53 to 1.39, non-inferiority P < 0.019). The MAD group demonstrated a larger reduction in asleep BP compared to the CPAP group. The prevalence of excessive daytime sleepiness in the MAD group decreased from 30.3% at baseline to 10.1% at 12-month follow-up (P = 0.001), and from 38.5% to 7.7% in the CPAP group (P < 0.001). The between-group difference was 10.6% (P = 0.097). No significant within-group or between-group differences were observed in the prevalence of arrhythmias and plasma levels of cardiac biomarkers. CONCLUSION: At 12-month, MAD is non-inferior to CPAP for reducing 24 h mean arterial BP in participants with hypertension and increased cardiovascular risk. TRIAL REGISTRATION: NCT04119999.

Humans

Comparative safety and operative efficiency of surgical approaches for open reduction and internal fixation of mandibular condylar fractures: a systematic review and network meta-analysis.

BACKGROUND: The optimal surgical approach for mandibular condyle fractures remains controversial, particularly regarding the trade-off between facial nerve safety and surgical efficiency. METHODS: Our systematic review and frequentist NMA analyzed studies evaluating open reduction and internal fixation (ORIF) for mandibular condyle fractures. The primary safety outcome was transient or persistent (&#x2265;6 months) facial nerve weakness. The efficiency outcome was operative exposure time. Surgical approaches were categorized, and random-effects NMAs estimated odds ratios (ORs) and mean differences (MDs). Treatments were ranked using P-scores, and clustered rankings explored safety-efficiency relationships. RESULTS: Overall, 121 studies (n&#x202f;=&#x202f;6659 patients) were included. For facial nerve safety, endoscope-assisted (EA), preauricular transmasseteric anteroparotid (PATMA), and high submandibular (HSMA) approaches ranked highest, while the retromandibular transparotid (RMTA) approach carried a higher risk. Analyses restricted to persistent weakness yielded consistent results. For exposure time, submandibular (SM), HSMA, and retromandibular transmasseteric anteroparotid (RMTMA) approaches were most efficient. Clustered ranking analysis identified HSMA and RMTMA as achieving the best overall balance between safety and efficiency. Subgroup analyses confirmed the overall hierarchy, though evidence for high-level and intracapsular fractures remains limited. CONCLUSIONS: HSMA and RMTMA offer an optimal compromise between safety and efficiency for extracapsular condylar fractures, while EA may minimize nerve injury risk where technical expertise allows. High-quality comparative trials - particularly for intracapsular fractures - are warranted.

Humans

Effectiveness of kinesiologic tape in the management of postoperative trismus, discomfort, and edema in mandibular fractures: a randomized controlled trial.

OBJECTIVE: This study compared kinesiologic taping (KT) with conventional elastic adhesive bandaging in managing postoperative morbidity following open reduction and internal fixation. STUDY DESIGN: In this prospective, randomized controlled trial conducted at KLE Dr Prabhakar Kore Hospital, 26 patients with unilateral mandibular fractures were allocated into two groups: Group 1 received an elastic adhesive bandage (n = 13) and Group 2 used KT (n = 13). Pain (Visual Analog Scale), facial swelling (standardized linear measurements), and maximum interincisal distance were recorded at baseline and on postoperative Days 2 and 5. Data were analyzed using repeated measures ANOVA and independent t tests (p < .05). RESULTS: The KT group showed significantly lower pain scores and reduced facial edema at Days 2 and 5 compared with controls (P < .05). Trismus improved in both groups without significant intergroup differences. No adverse effects were observed. CONCLUSIONS: KT is a safe and effective adjunct for reducing early postoperative pain and edema after mandibular fracture fixation.

Humans

Virtual surgical planning-assisted versus free-hand head and neck reconstruction: Systematic review, meta-analysis, and a novel classification.

Virtual surgical planning (VSP)-assisted reconstruction is increasingly used as an alternative to conventional free-hand (FH) techniques in mandibular and maxillary free-flap reconstruction. This systematic review and meta-analysis compared clinical outcomes and proposed a Reconstruction Complexity-Completeness classification. PubMed/MEDLINE, Scopus, Web of Science, Google Scholar, and reference lists were searched from inception to 20 June 2026. Comparative studies were eligible. Risk of bias was assessed using RoB 2 or the Newcastle-Ottawa Scale. Random-effects meta-analyses used restricted maximum likelihood estimation and Hartung-Knapp adjustment. Forty-two studies included 2763 patients (1204 VSP; 1559 FH). VSP significantly reduced operative time (33 studies; MD -64.75&#x202f;min, 95% CI -83.51 to -46.00), ischemia time (15 studies; MD -37.40&#x202f;min, 95% CI -48.97 to -25.82), and hospital stay (16 studies; MD -1.75 days, 95% CI -3.43 to -0.08). VSP was associated with significantly lower odds of bony non-union (OR 0.31, 95% CI 0.16-0.59) and malocclusion (OR 0.14, 95% CI 0.03-0.64), whereas flap loss, surgical site infection, and plate exposure did not differ significantly. VSP-assisted reconstruction was associated with improved operative efficiency, shorter hospitalization, and lower odds of bony non-union and malocclusion, while no statistically significant differences were detected in flap loss, surgical site infection, or plate exposure. The proposed classification may support complexity-adjusted reporting and comparison.

Humans

Oxygen-controlled gamma-irradiation and annealing enable terminal processing of collagen-based biomaterials.

Gamma irradiation is a widely adopted method for terminal sterilization of medical devices; however, its application to collagen-based extracellular matrix (ECM) materials remains limited due to radiation-induced degradation of structural integrity and mechanical performance. Here, we present an engineered terminal-processing strategy that combines oxygen controlled gamma irradiation (25-30&#xa0;kGy) with post-irradiation dry-heat annealing to preserve ECM functionality while achieving effective sterilization. By modulating oxygen availability during irradiation, this approach alters radical reaction pathways, suppresses oxygen-mediated oxidative degradation, and generates a metastable radical-containing intermediate, which is subsequently converted into a structurally stabilized collagen network through thermal annealing. As a result, the treated matrices preserved ECM integrity and recovered clinically relevant mechanical properties. Furthermore, the process achieved cumulative viral reductions exceeding 6 log10 across a representative panel including enveloped and non-enveloped DNA and RNA viruses, demonstrating compatibility with sterility assurance and viral safety requirements for biologically derived medical devices. Notably, preliminary observations indicate that mechanical integrity can be partially preserved even at elevated irradiation doses up to 50&#xa0;kGy, suggesting potential applicability to sterilization validation frameworks requiring higher assurance levels. Overall, this work establishes a mechanistically grounded terminal-processing paradigm that enables control of radical fate, decouples sterilization efficacy from material degradation, and integrates sterilization, viral safety, and functional preservation into a unified and scalable framework for collagen-based biomaterials. This concept repositions gamma-irradiation from a purely degradative process to a controllable tool for tuning collagen structure and performance.

Gamma Rays

Effectiveness and usability of artificial intelligence-powered assistive technologies in Supporting daily activities of children with cerebral palsy: a systematic review.

BACKGROUND: Cerebral Palsy (CP) is the main cause of motor disabilities in childhood, necessitating innovative approaches to rehabilitation and assistive technology (AT). Simultaneously, artificial intelligence (AI) is increasingly being integrated into devices to create more adaptive, personalized, and effective AT. This systematic review aimed to evaluate the effectiveness and usability of AI-powered assistive technologies designed to support daily activities and rehabilitation in children with CP. MATERIALS AND METHODS: Five databases, including Scopus, Web of Science, PubMed, Embase, and IEEE Xplore, were systematically searched, and 23 articles were included in the final analysis. Articles were identified, selected, and categorized into emerging thematic areas based on the primary function and application of the technology. RESULTS: Five key thematic topics were identified: 1) AI-driven motor rehabilitation and gait training for functional mobility; 2) intelligent assessment and monitoring systems for clinical decision support; 3) AI-supported communication, social interaction, and intention recognition tools; 4) gamified and virtual reality-based interventions to enhance engagement and usability; and 5) smart assistive systems supporting daily living and independent mobility. The findings demonstrate a strong trend toward the application of AI technologies in personalized, engaging, and data-driven interventions for children with CP. However, the field is predominantly in the proof-of-concept stage, with limitations including small sample sizes, lack of long-term clinical validation, challenges in user-centered design, and usability for children with CP. CONCLUSION: AI-powered assistive technologies hold significant potential for transforming the care of children with CP by enabling highly personalized and engaging interventions. To actualize this potential, future work must realize that practical application remains challenging owing to limited clinical validation, technological integration, and usability barriers for children with CP. Future research must prioritize user-centered design and multidisciplinary collaboration to ensure that AI and robotic advancements improve the usability and quality of life for children with CP.

Humans

Effect of urinary catheter securement band on meatal pressure injury in male intensive care patients: A randomized controlled trial.

OBJECTIVES: To investigate the effectiveness of a urinary catheter securement band in preventing meatal pressure injury (meatal-PI) in male ICU patients, and to identify associated risk factors and the timing of injury development. METHODS: A total of 248 adult male ICU patients were randomly allocated to an intervention group (n&#xa0;=&#xa0;124) or a control group (n&#xa0;=&#xa0;124) between December 2024 and April 2025. The intervention group received a catheter securement band in addition to standard care, while the control group received standard care alone. Meatal-PI was evaluated daily using a structured monitoring form and a validated staging system. RESULTS: The incidence of meatal-PI was significantly lower in the intervention group (6.5%) compared with the control group (16.1%) (p&#xa0;=&#xa0;0.016). Multivariate analysis identified catheter securement, use of silicone catheters, higher Braden Scale scores, and shorter ICU length of stay as independent protective factors, while advanced age was associated with increased risk. Additional factors significantly associated with meatal-PI included comorbidities, higher device burden, latex catheter use, dry skin, lower Glasgow Coma Scale and Braden scores, sedation, and perineal oedema (p&#xa0;<&#xa0;0.001). CONCLUSIONS: The use of a catheter securement band significantly reduces the incidence of meatal-PI in male ICU patients. Incorporating catheter securement devices into routine nursing care, prioritising silicone catheter use, and performing regular meatal assessments may enhance patient safety by reducing the risk of device-related pressure injuries. Further research comparing different catheter securement methods across diverse patient populations is warranted. IMPLICATIONS FOR CLINICAL PRACTICE: The use of catheter securement bands may reduce the incidence of meatal-PI in male ICU patients. Incorporating standardized catheter stabilization strategies into routine intensive care nursing practice may enhance patient safety and support pressure injury prevention efforts.

Humans

Effect of Music on Pain, Anxiety, and Satisfaction During Intrauterine Device Application: A Randomized Clinical Trial.

This randomized controlled trial aimed to determine the effect of music played during intrauterine device (IUD) insertion on perceived pain, state anxiety, and satisfaction levels. The study was conducted with 70 women who applied to a maternal and child health and family planning center and were randomly assigned to the intervention and control groups using simple randomization. Data were collected using a Demographic Information Form, the State-Trait Anxiety Inventory (STAI-I), and the Visual Analog Scale (VAS), as well as Bluetooth speakers and the musical piece Evgeny Grinko-Valse. Participants in the intervention group listened to music before and during the IUD insertion procedure, whereas the control group received routine care only. Data were analyzed using SPSS version 26 with appropriate descriptive and inferential statistical methods. Women in the music group had significantly lower perceived pain (p&#x2009;<&#x2009;0.001) and state anxiety levels during the procedure (p&#x2009;=&#x2009;0.022), and significantly higher satisfaction levels compared with the control group (p&#x2009;<&#x2009;0.001). In addition, post-procedure state anxiety levels were positively correlated with pain intensity experienced during and after the procedure (r&#x2009;=&#x2009;0.542 and r&#x2009;=&#x2009;0.496, respectively; p&#x2009;<&#x2009;0.001), and negatively correlated with procedural satisfaction (r&#x2009;=&#x2009;-0.652; p&#x2009;<&#x2009;0.001). These findings suggest that listening to music during IUD insertion may help reduce pain and anxiety while potentially enhancing patient satisfaction. Trial Registration: NCT06215183.

Humans

Assessment of Surgical Salvage Outcomes for Exposed Cranial Neuromodulating Devices.

OBJECTIVES: Implanted neuromodulating devices (NMDs) such as cochlear implants (CIs) and deep brain stimulators (DBSs) are commonly used in modern medicine. Rarely, complications arise post-operatively, including hardware exposure. Traditional teaching suggests that these devices require removal if exposed; however, surgical salvage is a high risk, high reward alternative. We review our single institution experience managing NMD exposure with surgical salvage. METHODS: Retrospective chart review was performed on individuals who had a NMD implanted and underwent an attempt at surgical salvage for exposure during the study period (January 01, 2021 through December 31, 2023). Study outcome success was defined as maintaining a functional NMD 1&#x2009;year after salvage was attempted. Surgical techniques associated with successful salvage were compared. RESULTS: Nine of 729 patients (1.2%) implanted with NMDs experienced hardware exposure during this 2-year study period. Nine subjects were referred for NMD salvage; however, only 6 of 9 subjects (66.7%, CI&#x2009;=&#x2009;3; DBS&#x2009;=&#x2009;3) underwent NMD salvage attempts. Four of the subjects had successful salvage demonstrated successful salvage with a functioning NMD and without wound healing concerns 1&#x2009;year after their salvage procedure. CONCLUSIONS: Classic teaching states that exposed NMDs require explantation. However, this approach necessarily imposes time without benefit from the NMD between explantation and reimplantation. Our experience demonstrates that surgical salvage can be a successful alternative for the majority (66.7%) of individuals.

Humans

Phase 1 Study Evaluating Gefurulimab Pharmacokinetics and Safety Following Delivery Via Autoinjector or Prefilled Syringe With Needle Safety Device in Healthy Adults.

PURPOSE: Gefurulimab, a novel dual-binding nanobody targeting complement component 5 (C5), is in clinical development for anti-acetylcholine receptor antibody-positive generalized myasthenia gravis. Gefurulimab has a low molecular weight, enabling subcutaneous (SC) self-administration by autoinjector (AI) or prefilled syringe with needle safety device (PFS-SD). We compared gefurulimab pharmacokinetic (PK) exposure and safety in healthy adults following a single SC dose administered by AI versus PFS-SD. METHODS: In this phase 1, open-label, randomized, parallel-group study (NCT06208488), healthy participants aged 18 to 65 years were stratified by weight and randomized equally to 1 of 6 combination groups of device and injection site (abdomen/thigh/upper arm). Participants received a single SC dose of gefurulimab on day 1 and were assessed throughout the 92-day evaluation period. Primary endpoints were PK parameters for each device: maximum observed concentration (Cmax) and area under the serum concentration-time curve (AUCinf, AUClast). PK across injection sites, pharmacodynamics, safety, immunogenicity, and device performance were also assessed. FINDINGS: Overall, 175 participants were randomized: AI (n = 87), PFS-SD (n = 88). Geometric least squares mean ratios (90% CI) comparing AI/PFS-SD for Cmax, AUCinf, and AUClast were 97.6% (94.5-100.8), 99.6% (96.1-103.3), and 98.8% (95.2&#x2012;102.6), respectively. Secondary analyses found no meaningful differences in PK parameters across injection sites. Serum-free C5 concentrations over time, treatment-emergent adverse event (TEAE) profiles, and antidrug antibody responses were similar between cohorts. Most TEAEs were mild; none led to study discontinuation. IMPLICATIONS: SC administration of gefurulimab by AI and PFS-SD was well tolerated with comparable exposure, meeting bioequivalence criteria.

Humans

Prothrombin complex concentrate (PCC) vs. non-PCC strategies for warfarin reversal in left ventricular assist device recipients: A systematic review and meta-analysis.

BACKGROUND: Left ventricular assist devices (LVADs) prolong survival in end-stage heart failure, and warfarin thromboprophylaxis is recommended to prevent device thrombosis and thromboembolic complications. When bleeding occurs or emergency surgery is required, rapid anticoagulation reversal is critical. Prothrombin complex concentrate (PCC) provides rapid reversal; however, its risk-benefit profile in LVAD recipients remains unclear. We conducted a systematic review and meta-analysis comparing PCC with non-PCC strategies for warfarin reversal in LVAD recipients. METHODS: MEDLINE, Embase, and Scopus were searched through June 2025 for studies of PCC versus non-PCC strategies for warfarin reversal in LVAD recipients. Two reviewers independently extracted data. Random-effects models were used to pool arm-level estimates and to pool head-to-head comparisons using mean differences or risk ratios (RRs). RESULTS: Eighteen studies involving 779 patients were included. Arm-level pooled estimates for PCC versus non-PCC comparators were 24.0% versus 15.8% for mortality, 16.5% versus 12.1% for thrombotic events, and 3.1 versus 5.7 for FFP units. Arm-level time to INR correction was longer with PCC overall (16.5 versus 13.6&#xa0;h), driven by one elective cohort, but faster within the ICH subgroup (6.0 versus 13.7&#xa0;h). In head-to-head comparisons, PCC achieved faster INR correction than non-PCC comparators (mean difference&#xa0;-&#xa0;7.6&#xa0;h; p&#xa0;=&#xa0;0.001) and required fewer FFP units (-2.6&#xa0;units; p&#xa0;=&#xa0;0.019), with no significant difference in all-cause mortality (RR 1.14; p&#xa0;=&#xa0;0.490) or thrombotic events (RR 1.43; p&#xa0;=&#xa0;0.176). CONCLUSIONS: In head-to-head studies, PCC was associated with faster INR correction and lower FFP requirements than non-PCC strategies, whereas mortality and thrombotic events did not differ significantly. Given the observational evidence, wide confidence intervals, and heterogeneity, equivalent safety cannot be established, and prospective studies are needed to define the relative safety and effectiveness of the two approaches. IMPLICATIONS FOR CLINICAL PRACTICE: PCC-based strategies may be considered for urgent warfarin reversal in LVAD recipients, particularly when rapid INR reduction or avoidance of large-volume plasma transfusion is clinically important. Treatment decisions should account for the indication, bleeding severity, and underlying thrombotic risk. TRIAL REGISTRATION: CRD42024573925.

Humans

Analyzing the impact of subcutaneous injection needle, device, and administration characteristics on patient pain, anxiety, and safety: a systematic literature review.

The subcutaneous (SC) injection route is a commonly used and important method for therapeutic delivery of a wide range of compounds, and needle characteristics have a significant influence on patient pain, anxiety, safety, and other outcomes. This systematic review evaluates the evidence on how needle-specific characteristics (e.g. gauge, length, tip design, wall thickness, concealment) and administration- or device-related factors can affect patient-reported outcomes and clinical safety indicators during and following SC injections. A comprehensive search was conducted in MEDLINE, PubMed, Embase, and ClinicalTrials.gov in June 2024. Studies were included if they assessed the relationship between needle characteristics and pain, anxiety, safety, or related outcomes in individuals receiving SC injections. A dual-reviewer process was used for study selection, data extraction, and quality assessment. Sixty-two studies met inclusion criteria. Evidence consistently indicated that thinner and shorter needles reduced patient-reported pain and adverse events such as bruising and bleeding. Tapered and lubricated needles, hidden or retractable needle designs, and use of autoinjectors or prefilled syringes also contributed to reduced anxiety and improved user satisfaction. However, results were heterogeneous, and many studies lacked sufficient power or single-variable evaluation of individual needle parameters, limiting definitive conclusions. Needle characteristics significantly influence patient experience and safety with SC delivery. While both clinical evidence and practical experience clearly favor thinner, shorter, and concealed needles, further standardized, high-quality research is needed to isolate and quantify the specific contributions of individual needle characteristics to optimize injection practices and support patient-centered device design.

Humans

Glaucoma filtering surgery combined with phacoemulsification in the era of new aqueous humor filtration devices: A systematic review.

We evaluate the efficacy and safety of filtering glaucoma surgeries combined with phacoemulsification (PCE)-including new aqueous humor drainage devices-compared to standalone procedures. We performed a systematic search up to March 23, 2025, including all comparative studies assessing trabeculectomy (TRAB), non-penetrating deep sclerectomy (NPDS), Xen&#xae; Gel Stent (XEN), or Preserflo&#xae; MicroShunt (PMS) combined with PCE, versus the same surgery alone. Key exclusion criteria include inadequate follow-up (less than 12-month), absence of a defined success criterion, more than 50% of loss to follow-up at 12-month, and lens extraction performed without PCE. Main outcome was surgical success at &#x2265;&#x202f;12 months. Secondary outcomes included intraocular pressure (IOP) reduction, decrease in hypotensive medications, and rates of complications. A total of 27 studies were included for analysis. Among studies comparing TRAB/PCE with standalone TRAB, half reported similar success rates, while others favored standalone TRAB, particularly using strict IOP thresholds. Safety profiles were comparable. For NPDS/PCE, data mostly showed equivalent outcomes versus standalone NPDS, with comparable safety. In studies on XEN/PCE and PMS/PCE, results suggested similar rates of surgical success, efficacy in IOP and medication reduction, and safety compared to their stand-alone procedures. Small differences occasionally favored standalone procedures under stricter success definitions. Current evidence suggests that combined filtering glaucoma surgery provides long-term efficacy and safety comparable to standalone, though some subgroups and outcome thresholds may slightly favor standalone approaches. The limited availability of high-quality prospective trials underscores the need for further large-scale robust studies.

Humans

Prostate morcellation devices: a systematic review and meta-analysis of clinical outcomes and efficiency.

OBJECTIVE: To systematically evaluate the efficiency and safety of different prostate morcellators used during prostate enucleation for benign prostatic hyperplasia (BPH). METHODS: A systematic review was performed according to the Preferred Reporting Items for Systematic Review and Meta-analyses guidelines. PubMed/Medline, Scopus, and Web of Science were searched for studies published between October 2012 and May 2025. Studies reporting clinical outcomes of morcellators used during prostate enucleation were included. Primary outcome was morcellation efficiency (g/min). Secondary outcomes included intraoperative complications, device malfunction, and cost when available. Risk of bias (RoB) was assessed using the Risk Of Bias In Non-randomised Studies of Interventions (ROBINS-I), RoB 2 tool, and European Association of Urology case-series criteria. Random-effects meta-analyses and multilevel meta-regression adjusted for prostate volume were conducted. RESULTS: A total of 22 studies comprising 5980 patients were included, most undergoing holmium laser enucleation of the prostate. The most frequently evaluated devices were the Piranha&#x2122; (Richard Wolf GmbH, Knittlingen, Germany) and Lumenis VersaCut&#x2122; (Lumenis Ltd., Yokneam, Israel; 12 and 13 studies, respectively), followed by DrillCut&#x2122; (Karl Storz SE & Co. KG, Tuttlingen, Germany), MultiCut&#x2122; (Asclepion Laser Technologies GmbH, Jena, Germany), and Cyber Blade&#x2122; (Quanta System SpA, Milan, Italy) systems. Unadjusted weighted mean morcellation efficiency was 7.80&#x2009;g/min (95% confidence interval [CI] 6.26-9.34&#x2009;g/min) for Piranha, 4.70&#x2009;g/min (95% CI 3.61-5.79&#x2009;g/min) for VersaCut, 5.90&#x2009;g/min (95% CI 3.16-8.64&#x2009;g/min) for DrillCut, and 9.59&#x2009;g/min (95% CI 4.78-14.39&#x2009;g/min) for MultiCut. In volume-adjusted meta-regression using Piranha as reference, VersaCut remained significantly less efficient (-2.75&#x2009;g/min; 95% CI -4.58 to -0.92&#x2009;g/min; P&#x2009;=&#x2009;0.003), with an even greater difference in prostates >70&#x2009;mL (-4.34&#x2009;g/min). Bladder mucosal injury was the most frequently reported complication; however, relatively rare across all devices. Meta-analysis demonstrated a significantly higher risk with VersaCut compared to Piranha (risk ratio 3.22, 95% CI 1.81-5.71), with low heterogeneity. CONCLUSION: This systematic review provides a contemporary clinical benchmark of the efficiency and safety of currently available prostate morcellators. Oscillating blade systems, particularly the Piranha morcellator, demonstrated higher morcellation efficiency and a more favourable safety profile than reciprocating blade devices, with the largest performance differences observed in patients with larger prostates.

Humans

Use of wearable technologies for physical activity promotion in older adults: A systematic review.

This systematic review, conducted according to PRISMA guidelines and registered in PROSPERO (CRD420251055299), examined the use of wearable technologies for promoting physical activity (PA) in adults aged 60 years and older. Searches across five databases (PubMed, Scopus, Web of Science, CINAHL, Cochrane) identified 2438 records, of which only six randomized controlled trials published between 2021 and 2025 met inclusion criteria, with sample sizes ranging from 36 to 551 participants and mean ages between 65 and 79 years. Given the small number of included studies, findings should be interpreted as preliminary. The studies ranged from the standalone use of commercial trackers (Fitbit, Polar, ActiGraph) to multicomponent interventions combining wearables with physiotherapist feedback, telephone counseling, web-based platforms, or interactive cognitive-motor training. Wearables used alone, as in the REACT trial, produced small or non-significant PA effects. In contrast, interventions integrating devices with personalized feedback, professional support, or digital platforms, such as PROMOTE and TASMANIA, were associated with more consistent improvements in PA, physical function, and cognitive outcomes. Multicomponent programs, such as PEER and ICMT, reported broader benefits, including cognition, balance, and reductions in sedentary behavior, though these findings derive from individual trials and require replication. Risk of bias, assessed with the Cochrane Risk of Bias tool version 2 (RoB 2.0), was rated as "some concerns" for five studies and low for only one, mainly due to gaps in randomization reporting, missing data, and lack of preregistration. Tentatively, and based on a very limited evidence base, wearables may have greater impact when embedded within broader behavioral systems, incorporating feedback, coaching, or interactive components, rather than when used in isolation as passive monitoring tools. Adherence and psychosocial outcomes appeared related to comfort and perceived usefulness among older adults, though larger and more robust trials are needed to confirm these patterns.

Humans

One in three patients with positional obstructive sleep apnea does not benefit from positional therapy: Insights from a home-based trial.

PURPOSE: Positional obstructive sleep apnea (POSA) is the most common phenotype of obstructive sleep apnea, yet patient selection for positional therapy (PT) remains suboptimal. With this analysis we aimed to clarify how many patients with POSA may not require PT because they do not habitually sleep supine at home, and how many fail vibrotactile PT despite appropriate indication. METHODS: We conducted a retrospective observational study of consecutive adults with POSA evaluated at a tertiary sleep center between 2021 and 2024. All patients underwent a home-based trial with a neck-based vibrotactile positional therapy device (Night Shift&#x2122;), consisting of monitoring mode followed by therapy mode. Outcomes included the proportion of non-supine sleepers at home, failure rate of vibrotactile PT, device compliance and differences in supine sleep time between diagnostic testing and home monitoring. RESULTS: Of 92 screened patients, 74 met inclusion criteria (mean age 60.3&#x202f;&#xb1;&#x202f;13.2 years; mean AHI 22.9&#x202f;&#xb1;&#x202f;13.3 events/h). Fifteen percent (11/74) did not habitually sleep supine at home, indicating no clinical need for PT, and an additional 14.8% (11/74) failed vibrotactile PT. Overall, 30% of patients were either unlikely to benefit from PT or failed therapy. Non-response was frequently associated with psychotropic or sedative medication use and neurological or sleep-related comorbidities. CONCLUSION: A substantial proportion of patients diagnosed with POSA either do not require or fail vibrotactile treatment in real-world conditions. Incorporating a brief home monitoring and therapy trial into routine clinical practice may optimize patient selection, reduce unnecessary costs, and improve personalized management of POSA.

Humans

The Effect of Slow Deep Breathing Relaxation Exercise on Pain and Anxiety Levels During and Post-Chest Tube Removal After CABG.

Chest tube removal after coronary artery bypass graft is frequently reported by patients as stressful and painful, highlighting the need for effective nonpharmacological interventions. Slow deep breathing relaxation exercises (SDBREs) may serve as a simple nursing strategy to reduce discomfort. In this study, we aimed to evaluate the effect of SDBRE on pain and anxiety during and after chest tube removal following coronary artery bypass grafting in Nablus hospitals. An experimental design was used with 80 patients recruited from 2 hospitals. Participants were randomly assigned to either an intervention group (n = 40) that practiced SDBRE or a control group (n = 40) that received standard care. Data were collected through a self-administered questionnaire, the Numeric Pain Scale, and the Visual Anxiety Scale. Data collection occurred from March to October 2024. The intervention group reported significantly lower pain scores during removal (M: 5.325 vs 7.125, P < .001) and after removal (P < .001). Anxiety scores were significantly lower both during and after removal (P < .001). Pain correlated with duration, with more complex operations and prolonged chest tube insertion linked to higher scores. SDBRE significantly reduced pain and anxiety during and after chest tube removal, supporting its integration into routine postoperative nursing care.

Humans

Intraocular Pressure Changes Following Intraluminal Stent Removal From the Paul Glaucoma Implant: A Systematic Review and Meta-Analysis.

PURPOSE: This study aims to systematically review and perform a single-arm meta-analysis to comprehensively evaluate the effect of removal of intraluminal stent from the Paul glaucoma implant (PGI) on intraocular pressure (IOP) changes and to summarize its long-term efficacy and safety. CLINICAL RELEVANCE: Glaucoma remains one of the leading global causes of irreversible vision loss, necessitating effective surgical management for refractory cases. Glaucoma drainage devices are critical for these complex forms, and intraluminal stent removal from the PGI serves as a key strategy to titrate aqueous outflow and optimize long-term IOP control. METHODS: A systematic review was conducted by searching EMBASE, Medline, and CENTRAL. The meta-analysis ultimately included 5 observational studies. The Risk of Bias in Nonrandomized Studies of Interventions (ROBINS-I) tool was used to assess the quality of the included studies. Continuous outcomes (eg, postremoval stent IOP reduction) were analyzed using the mean difference (MD) with 95% confidence intervals (CI); dichotomous outcomes (eg, hypotony incidence) were evaluated using pooled proportion with 95% CI. All meta-analyses employed a random-effects model. RESULTS: Our meta-analysis included 5 studies, involving a total of 283 eyes. The meta-analysis revealed that removal of the stent leads to a significant and immediate IOP reduction. The IOP reduction (immediate postremoval stent IOP minus preremoval stent IOP) was significant, with a pooled MD of -9.09 mm Hg IOP (MD = 9.09; 95% CI = [-11.77, -6.41]). In the preremoval stent high-IOP (>21 mm Hg) subgroup, the IOP reduction is -11.82 (95% CI = [-10.14, -13.51]). This reduction was significantly greater than the preremoval stent low-IOP (<21 mm Hg) subgroup, whose reduction is -6.66 mm Hg (95% CI = [-5.55, -7.77]). Regarding safety, the pooled proportion of clinically hypotony was low and highly consistent (I&#xb2; = 0.00%) at only 0.03 (95% CI = [0.00, 0.15]). CONCLUSIONS: Intraluminal stent removal from the PGI is an effective and safe IOP-lowering intervention. Its IOP reduction effect is significantly more pronounced in patients with preremoval stent high IOP, providing crucial clinical guidance for managing persistently high IOP after PGI implantation.

Humans