Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Immunoassay”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Toxicological detection of pholcodine and its metabolites in urine and hair using radio immunoassay, fluorescence polarisation immunoassay, enzyme immunoassay, and gas chromatography-mass spectrometry.

Pholcodine (3-O-(2'-morpholinoethyl)-morphine) is used in many countries as an antitussive without analgesic or addictive properties. It is of forensic relevance that pholcodine interferes with opiate immunoassays. In this paper a gas chromatographic-mass spectrometric (GC-MS) procedure for the precise and sensitive detection of pholcodine and its metabolites in urine and hair, after acid hydrolysis, extraction and acetylation, is presented. Furthermore, detection of pholcodine using radio immunoassay (RIA), fluorescence polarisation immunoassay (FPIA) and enzyme immunoassay (EIA) for opiates is described. Using GC-MS, unmodified pholcodine could be detected in urine samples 4-7 weeks after ingestion of a single therapeutic dose of 50mg of pholcodine, the desmorpholinohydroxy metabolite for 1-2 weeks and the other metabolites (nor-, nordesmorpholinohydroxy-, hydroxy-, oxo- and noroxo-pholcodine) only during the first few hours. Morphine could also be detected in urine samples for the first few days. It was however mainly formed artificially during acid hydrolysis and only in trace amounts by metabolism. All the immunoassays tested gave positive results in urine samples during the first week taking the cut-off values recommended by the manufacturer into consideration. If values between the cut-off and the detection limit were taken into consideration, RIA and FPIA gave positive results for 2-4 weeks and EIA up to 2 weeks. Pholcodine could also be detected by RIA and GC-MS in samples of head hair clipped 10 weeks after ingestion of 50mg and in daily shaved samples of beard hair over a period of three weeks after ingestion of three doses of 60mg. It can be concluded that the widely used immunoassays for opiates show positive results in urine and hair samples for a long time after ingestion of the non-opioid pholcodine and that these results can be confirmed by the GC-MS procedure described in this paper.

Codeine↗

Enzyme immunoassay, kinetic microparticle immunoassay, radioimmunoassay, and fluorescence polarization immunoassay compared for drugs-of-abuse screening.

The newest formulation of the Syva EMIT assay for drugs of abuse, EMIT II, and a new immunoassay, OnLine (Roche), utilizing the kinetic interaction of microparticles in solution (KIMS) methodology, RIA tests, and TDx fluorescence polarization immunoassay (FPIA) procedures were compared for marijuana, cocaine, opiates, and barbiturates. Both EMIT II and OnLine immunoassays were performed with a Hitachi 717 analyzer. Calibration curves, the degree of separation between negative and cutoff calibrators, precision, likelihood of carryover from positive to negative samples, and overall ease and speed of analysis were evaluated. RIA and OnLine detected 99% of gas chromatography/mass spectrometry (GC/MS)-confirmed marijuana samples; TDx, 95%; and EMIT II, 88%. All four immunoassays detected approximately 99% of confirmed cocaine-positive urines. RIA, OnLine, and TDx all detected 100% of opiate-confirmed samples; EMIT II, 97%. Barbiturate assays exhibited the greatest disparity, with OnLine and TDx detecting 100% of confirmed positives; EMIT II, 88%; and RIA, 78%. For a variety of reasons, we prefer the fully automated EMIT II and OnLine assays for high-volume urine testing, in comparison with our laboratory's semiautomated RIA tests and the limited-throughput TDx system. The four immunoassays investigated delivered comparable performance in terms of detection rates for GC/MS-confirmed positives for some drugs but not for others.

Enzyme Multiplied Immunoassay Technique↗

Specificity of immunoassays. II. Heterogeneity of specificity of antibodies in antisera used for steroid immunoassay and the selective blocking of less specific antibodies, including a new method for the measurement of immunoassay specificity.

Practical aspects of the measurement of the specificity of immunoassay are reviewed. Antibody heterogeneity in an antiserum makes a pragmatic rather than a theoretical approach necessary. A new method for the measurement of immunoassay specificity is described. This method is based on the errors caused by the cross-reacting antigens and is directly relevant to the validity of results obtained by immunoassay methods. The effect of selectively blocking the least specific antibodies in antisera raised against steroid haptens is tested. The practical consequences of these considerations are tested using steroid radioimmunoassay and enzyme-immunoassay.

Androgens↗

Evaluation of the Boehringer Mannheim ES 300 immunoassay analyzer and comparison with enzyme immunoassay, fluorescence polarization immunoassay, and radioimmunoassay methods.

The ES 300 (Boehringer Mannheim Diagnostics, Indianapolis, IN) is a new automated immunoassay analyzer intended for the quantitative determination of a wide range of analytes. We compared its performance to enzyme immunoassay (EIA), fluorescence polarization immunoassay (FPIA), and radioimmunoassay (RIA) methods for cortisol, digoxin, ferritin, prolactin, T4-uptake, total-T3, and TSH. The ES 300 methods showed excellent precision and the manufacturers' linearity claims were met in all cases. Cortisol, prolactin, total-T3, and TSH showed no bias and acceptable correlation with other methods. Digoxin, ferritin and total T4 showed positive bias but acceptable correlation. The ES 300 T4-uptake correlated poorly with the TDx method and showed positive bias; however, these assays appear comparable (although deficient) in diagnostic sensitivity when compared to TSH and T4 data for the same patient population. In all, we found the ES 300 to be an acceptable instrumental alternative for the high volume immunoassay laboratory.

Blood Chemical Analysis↗

An evaluation of four different luminescence immunoassay systems: CELIA (chemiluminescent immunoassay), SPALT (solid-phase antigen luminescence technique), ILMA (immunoluminometric assay) and ILSA (immunoluminometric labelled second antibody). A critical study of macro solid phases for use in immunoassay systems, Part III.

The performance of different solid-phase luminescence immunoassays has been documented using four different assay concepts. These are CELIA (chemiluminescence immunoassay), SPALT (solid-phase antigen luminescence technique), ILMA (immunoluminometric assay) and ILSA (immunoluminometric labelled second-antibody assay). CELIA is analogous to a solid-phase radioimmunoassay and uses a labelled antigen, SPALT and ILSA use a labelled second (species-specific) antibody and ILMA a labelled substance-specific antibody, i.e. analogous to the immunoradiometric assay. Both bioluminescent and chemiluminescent labels have been used. Pyruvate kinase was used for bioluminescence and diazoluminol and N-(4-amino-butyl)-N-ethyl isoluminol hemisuccinamide for chemiluminescence. Relevant quality-control parameters and reference ranges have been given for the optimised assays. Assays described are: thyroxine, thyroxine binding globulin, cortisol, caeruloplasmin, ferritin and C-reactive protein. Luminescence immunoassays with coefficients of variation comparable with radioimmunoassay have been designed, values of under 5% being obtainable within the working range of the assay.

Animals↗

Evaluation of instrumental, nonisotopic immunoassays (fluorescence polarization immunoassay and enzyme-multiplied immunoassay technique) for cyclosporine monitoring in whole blood after kidney and liver transplantation.

Two new instrumental methods, an enzyme-multiplied immunoassay technique (EMIT) and a fluorescence polarization immunoassay (FPIA), were evaluated for monitoring of cyclosporine (CyA) in whole blood samples of renal and liver transplant patients. They are considered as being specific to the parent drug and they were compared with a specific radioimmunoassay (RIA) and a nonspecific FPIA. The data reveal that the novel procedures provide slightly overestimated CyA levels compared with specific RIA (6-12% for EMIT, 20-25% for FPIA). For both assays, intrarun and interrun reproducibilities were found to be in the 2-8% range. The ease of performance and the possibility of performing approximately 40 assays/h make the two methodologies very attractive for both routine and emergency analyses. These approaches are viewed to be complementary to the only previously available instrumental method, the nonspecific FPIA, which provides three- to fourfold higher CyA levels than those obtained with specific methods. Specific and nonspecific monitoring of CyA levels allowed variations in proportions of metabolites to total CyA and metabolites to be distinguished. A higher percentage and variability of cross-reacting metabolites were found in whole blood samples after liver transplantation compared with those in blood of kidney transplant recipients.

Cyclosporine↗

Performance of a time-resolved fluorescence immunoassay for measuring varicella-zoster virus immunoglobulin G levels in adults and comparison with commercial enzyme immunoassays and Merck glycoprotein enzyme immunoassay.

Highly sensitive and specific, quantitative assays are needed to detect varicella-zoster virus (VZV) immunoglobulin G in human sera, particularly for determining immune status and response following vaccination. A time-resolved fluorescence immunoassay (TRFIA) has been developed, and its performance was compared to that of two commercial enzyme immunoassays (EIAs) and Merck glycoprotein EIA (gpEIA). The TRFIA had equivalent sensitivity (97.8%) and high specificity (93.5%) in relation to gpEIA. A commercial (Behring) EIA compared favorably with TRFIA in terms of sensitivity (98.4%) but had lower specificity (80.7%). Another commercial EIA (Diamedix) had high specificity (97.1%) but low sensitivity (76.4%) compared to TRFIA if equivocal test results were treated as negative for VZV antibody. A novel feature of the TRFIA was that the cutoff was generated using population mixture modeling and was expressed in mIU/ml, as the assay was calibrated using the British standard VZV antibody.

Adult↗

Particle counting immunoassay for urinary cotinine. Comparison with chromatography, enzyme-linked immunoassay and fluorescence polarization immunoassay.

Urinary cotinine was measured according to its inhibitory activity on the agglutination of cotinine-coated latex particles by anti-cotinine antibodies, the agglutination being measured by optical counting of the remaining non-agglutinated particles (particle counting, PaC). The detection limit was 0.03 microgram/ml and the practical range extended from 0.03 to 3.9 micrograms/ml. The correlation results of 320 urine samples with those of high pressure liquid chromatography, enzyme-linked (Coti-Tracq EIA, Serex Inc., Maywood, NJ, USA), and fluorescence polarization immunoassay (TDX instrument, Abbott, Abbott Park, IL, USA) were r = 0.90, r = 0.69, r = 0.87, respectively, whereas the correlation coefficients between the assays other than particle counting ranged from 0.62 to 0.88. PaC does not require any separation step and can thus be easily automated.

Chromatography, High Pressure Liquid↗

Rapid and ultrasensitive enzyme immunoassay (thin aqueous layer immune complex transfer enzyme immunoassay) for HIV-1 p24 antigen.

The immune complex transfer enzyme immunoassay for HIV-1 p24 antigen was performed in three different ways (in the present immunoassays I, II, and III) within much shorter periods of time than previously reported. In the present (simultaneous) immunoassay I, p24 antigen was incubated simultaneously with 2,4-dinitrophenyl-biotinyl-bovine serum albumin-affinity-purified rabbit anti-p24 Fab' conjugate and monoclonal mouse anti-p24 Fab'-beta-D-galactosidase conjugate in a total volume of 19 microL for 15 min to form the immune complex comprising the three components. The reaction mixture was incubated with a polystyrene bead of 6.35 mm in diameter coated with affinity-purified (anti-2,4-dinitrophenyl group) IgG for 5 min to trap the immune complex. After washing, the polystyrene bead was incubated with 35 microL of epsilonN-2,4-dinitrophenyl-L-lysine for 15 min to elute the immune complex (the first eluate) and, after removing the first eluate, with an additional 35 microL of epsilonN-2,4-dinitrophenyl-L-lysine for 1 min (the second eluate). The first and second eluates were incubated with a polystyrene test tube (12 x 75 mm) coated with streptavidin for 15 min. In the present (sequential) immunoassay II, a polystyrene bead of 6.35 mm in diameter successively coated with affinity-purified (anti-2,4-dinitrophenyl group) IgG and 2,4-dinitrophenyl-biotinyl-bovine serum albumin-affinity-purified rabbit anti-p24 Fab' conjugate was incubated with p24 antigen in a total volume of 20 microL for 5 min and subsequently with monoclonal mouse anti-p24 Fab'-beta-D-galactosidase conjugate in a volume of 5 microL for 20 min. The immune complex formed on the polystyrene bead was transferred to a polystyrene test tube coated with streptavidin as described above. In the present (sequential) immunoassay III, p24 antigen was incubated with monoclonal mouse anti-p24 Fab'-beta-D-galactosidase conjugate in a total volume of 19 microL for 10 min and with a polystyrene bead of 6.35 mm in diameter coated successively with affinity-purified (anti-2,4-dinitrophenyl group) IgG and 2,4-dinitrophenyl-biotinyl-bovine serum albumin-affinity-purified rabbit anti-p24 Fab' conjugate for 20 min. The immune complex formed on the polystyrene bead was transferred as described above. The incubations were performed at room temperature either by shaking the polystyrene beads (one/assay) and the reaction mixtures in styrol test tubes (13.3 x 54 mm and 2.1 g) so as to randomly rotate the polystyrene beads or by rotating the polystyrene test tubes (12 x 75 mm) containing the reaction mixtures, so that small drops (19 to 70 microL) of the reaction mixtures evenly contacted all parts of the solid phase surfaces during the incubations (although they contacted only small parts of the solid phase surfaces at a time) to continuously mix thin aqueous layers covering the solid phase surfaces with the rest of the reaction mixtures. (Therefore, these immunoassays are called thin aqueous layer immunoassays.) The detection limits of p24 antigen by 1 hr assay of bound beta-D-galactosidase activity in the present immunoassays I, II, and III were 0.1, 0.2 and 0.1 amol/assay, respectively, and were slightly higher than or equal to that by the previously reported immune complex transfer enzyme immunoassay, in which the immune complex was formed for 4 hr, was trapped for 16 hr, and was transferred for 3 hr followed by 1-hr assay of bound beta-D-galactosidase activity. By 20-hr assay of bound beta-D-galactosidase activity, the detection limit of p24 antigen was further lowered to 10 zmol/assay in the present (simultaneous) immunoassay I and to 3 zmol/assay in the present (sequential) immunoassay III. However, the nonspecific reaction(s) with serum samples from HIV-1 seronegative subjects hampered the improvement of the detection limit by 20-hr assay of bound beta-D-galactosidase activity.

Acquired Immunodeficiency Syndrome↗

Ultrasensitive and rapid enzyme immunoassay (thin aqueous layer immune complex transfer enzyme immunoassay) for antibody IgG to HIV-1 p17 antigen.

The immune complex transfer enzyme immunoassay for antibody IgG to HIV-1 p17 antigen was performed in two different ways (the present immunoassays I and II) within shorter periods of time than previously reported. In the present (simultaneous) immunoassay I, antibody IgG to HIV-1 p17 antigen in 10 microL of serum samples was incubated simultaneously with 2,4-dinitrophenyl-maltose binding protein-recombinant p17(rp17) fusion protein and rp17-beta-D-galactosidase conjugate in a total volume of 22 microL for 10 min to form the immune complex comprising the three components. The reaction mixture was incubated with a polystyrene bead of 6.35 mm in diameter coated with affinity-purified (anti-2,4-dinitrophenyl group) IgG for 5 min in a styrol test tube (13.3 x 54 mm and 2.1 g) to trap the immune complex. After washing, the polystyrene bead was incubated with 30 microL of epsilonN-2,4-dinitrophenyl-L-lysine solution in a polystyrene tube (12 x 75 mm) coated with affinity-purified (antihuman IgG gamma-chain) IgG for 10 min to transfer the immune complex. In the present (sequential) immunoassay 11, a polystyrene bead of 6.35 mm in diameter coated successively with affinity-purified (anti-2,4-dinitrophenyl group) IgG and 2,4-dinitrophenyl-maltose binding protein-rp17 fusion protein was incubated in a styrol test tube (13.3 x 54 mm and 2.1 g) sequentially with antibody IgG to HIV-1 p17 antigen in 10 microL of serum samples in a total volume of 16 microL for 5 min and subsequently with rp17-beta-D-galactosidase conjugate in a volume of 10 microL for 5 and 10 min. The immune complex formed on the polystyrene bead was transferred to a polystyrene tube coated with affinity-purified (antihuman IgG gamma-chain) IgG for 5 and 10 min in the same way as in the present immunoassay I. During the incubations, the styrol test tubes containing the polystyrene beads and reaction mixtures were shaken, and the polystyrene test tubes were rotated with shaking, so that the polystyrene beads were rotated randomly, and small drops (16 to 30 microL) of the reaction mixtures evenly contacted all parts of the solid phase surfaces during the incubations, though only small parts of the solid phase surfaces were contacted at one time. The intent was to continuously mix thin aqueous layers of the reaction mixtures covering the solid phase surfaces with the rest of the reaction mixtures. (Therefore, these immunoassays were called thin aqueous layer immunoassays.) beta-D-Galactosidase activity bound to the polystyrene tubes was assayed by fluorometry for 30 and 60 min. The present immunoassays I and II, in which only 15 to 25 min were used for the immunoreactions, were as sensitive if not more so than the previous immune complex transfer enzyme immunoassay requiring 150 min for the immunoreactions. In these earlier immunoreactions, the immune complex comprising the three components formed by 30 min incubation was trapped onto two polystyrene beads (3.2 mm in diameter) coated with affinity-purified (anti-2,4-dinitrophenyl group) IgG for 60 min, and was then transferred to two polystyrene beads (3.2 mm in diameter) coated with affinity-purified (antihuman IgG y-chain) IgG for 60 min in a total volume of 150 microL. Furthermore, the present (sequential) immunoassay 11 (and probably I) could become approximately 10 times more sensitive by assaying bound beta-D-galactosidase activity for a longer period of time (10 h), since beta-D-galactosidase activity, bound nonspecifically in the presence of serum samples from HIV-1 seronegative subjects, was considerably low.

2,4-Dinitrophenol↗

Noncompetitive enzyme immunoassay (hetero-two-site enzyme immunoassay) for gamma 2-melanocyte-stimulating hormone (gamma 2-MSH) and measurement of immunoreactive gamma 2-MSH in plasma of healthy subjects.

A noncompetitive enzyme immunoassay (hetero-two-site enzyme immunoassay) for gamma 2-melanocyte-stimulating hormone (gamma 2-MSH) was developed. gamma 2-MSH (1-12) was biotinylated, trapped onto an anti-gamma 2-MSH (1-12) IgG-coated polystyrene bead, eluted at pH 1 after washing to eliminate other biotinylated substances, and measured using two streptavidin-coated polystyrene beads and affinity-purified anti-gamma 2-MSH (1-12) Fab'-peroxidase conjugate. The detection limit of gamma 2-MSH (1-12) was 10-30 amol (16-48 fg)/assay and 130-400 fmol (210-630 pg)/L of plasma. There was little or only slight cross reaction with alpha-MSH, beta-MSH, and gamma 1-MSH. By this immunoassay, the concentration and molecular size of immunoreactive gamma 2-MSH in plasma of healthy subjects were examined, and the results were compared with those by competitive enzyme immunoassay. Immunoreactive gamma 2-MSH measured by competitive enzyme immunoassay was a mixture of substances with high molecular weights (100-500 kDa), and its concentration was calculated to be 50-60 pmol/L using gamma 2-MSH (1-12) as standard. Immunoreactive gamma 2-MSH detected by the noncompetitive enzyme immunoassay after removal of high molecular weight substances was not homogeneous and smaller than gamma 2-MSH (1-12), and its concentration was approximately 1 pmol/L. The exact nature of these immunoreactive gamma 2-MSHs remains to be elucidated. gamma 2-MSH (1-12) added to plasma was degraded rapidly, and the concentration of gamma 2-MSH (1-12) was very low, if any, in plasma of healthy subjects.

Adult↗

Early detection of antibodies to human immunodeficiency virus 1 by a third-generation enzyme immunoassay. A comparative study with the results of second-generation immunoassays and western blot.

The aim of the study was to examine the sensitivity and the specificity of a HIV-1/HIV-2 third-generation enzyme immunoassay, the Abbott recombinant HIV-1/HIV-2 third-generation enzyme immunoassay, which is reported to detect simultaneously IgG and IgM. Sensitivity was evaluated with sera from seropositive subjects and a series of samples from eight HIV-1 seroconverting subjects. Results were compared with Western blot, second-generation immunoassays (including Vidas HIV-1 + 2) and an HIV-1 antigen assay. Specificity was studied with sera collected from a low-risk population and sera with false-reactive enzyme immunoassays results. In seven cases, the third-generation immunoassay detected HIV-antibodies several days earlier (range 4 to > or = 9 days) than the Western blot test according to the criteria proposed by the Association of State and Territorial Public Health Laboratory Directors, ie, positive with two of the three bands-gp160 or gp120, gp41, and p24. In the last case detection occurred at the same time as Western blot. The second-generation tests generally detected HIV-antibodies at the same time as Western blot. Antigaenemia was positive in the first samples tested in most cases, prior to or simultaneously with the Abbott third-generation test first reactivity, before the second generation tests and the Western blot test. In most cases, the disappearance of detectable HIV antigen was observed, and was concurrent with the development of the antibodies immune response. For our low-risk population, the current third-generation EIA test obtained a false-reactive rate of 0.26%. Our data indicate that the Abbott third-generation immunoassay is more sensitive than the Western blot test and the second-generation tests. The addition of a third-generation assay to the strategy for HIV-antibody screening may indeed be of interest and could make it possible to decrease the number of false-negative results.

Blotting, Western↗

More reliable diagnosis of infection with human immunodeficiency virus type 1 (HIV-1) by detection of antibody IgGs to pol and gag proteins of HIV-1 and p24 antigen of HIV-1 in urine, saliva, and/or serum with highly sensitive and specific enzyme immunoassay (immune complex transfer enzyme immunoassay): a review.

Ultrasensitive enzyme immunoassays (immune complex transfer enzyme immunoassays) were developed for antibody IgGs to HIV-1 using recombinant reverse transcriptase (rRT), p17 (rp17), and p24 (rp24) as antigens. Antibody IgGs were reacted with 2,4-dinitrophenyl-recombinant antigens and recombinant antigen-beta-D-galactosidase conjugates, and the immune complexes formed, comprising the three components, were trapped onto polystyrene beads coated with (anti-2,4-dinitrophenyl group) IgG. After washing, the immune complexes were eluted from the polystyrene beads with excess of epsilon N-2,4-dinitrophenyl-L-lysine and were transferred to clean polystyrene beads coated with (antihuman IgG gamma-chain) IgG. beta-D-Galactosidase activity bound to the last polystyrene beads was assayed by fluorometry. By transfer of the immune complexes from one solid phase to another, the nonspecific binding of the beta-D-galactosidase conjugates was minimized and the sensitivity was markedly improved. The immune complex transfer enzyme immunoassays using rRT, rp17, and rp24 as antigens were 300-1,000-fold, 1,000-3,000-fold, and 30-100-fold, respectively, more sensitive than Western blotting for the corresponding antigens and 10-300-fold more sensitive than a conventional ELISA and a gelatin particle agglutination test. For urine (100 microliters), whole saliva (1 microliter), and serum (1 microliter) samples, the sensitivity and specificity of the immune complex transfer enzyme immunoassay using rRT as antigen were both 100%. However, for urine samples in which the specific activities of antibody IgG to RT, p17, and p24 were much lower than those in serum samples probably due to degradation by the kidney, a longer assay of bound beta-D-galactosidase activity or/and a concentration process for urine was required. The use of more than 1 microliter of whole saliva was recommended for reliable diagnosis of the infections, whereas 1 microliter of serum was sufficient for the purpose. The positivity with rRT as antigen could be confirmed by demonstration of antibody IgGs to p17 and p24 in most of the urine, whole saliva, and serum samples. In HIV-1 seroconversion serum panels, antibody IgG to p17 was detected as early as or even earlier than antibodies to HIV-1 by a conventional ELISA or/and a gelation particle agglutination test, whereas antibody IgGs to RT and p24 were detected as early as or later than antibody IgG to p17. Thus the uses of rRT and rp17 as antigens were advantageous over that of the other antigens for randomly collected serum samples probably long after the infection and serum samples at early stages of the infection, respectively. On the basis of these results and other reports, the immune complex transfer enzyme immunoassay was developed for simultaneous detection of p24 antigen and antibody IgGs to RT and p17 in a single assay tube, and the window period (8 weeks, although widely variable), during which diagnosis of HIV-1 infection is not possible due to the absence of detectable antibodies to HIV-1, was shortened by 2 weeks. As a result, the simultaneous detection made possible not only as early diagnosis as that by detection of p24 antigen, but also as reliable diagnosis as that by detection of antibodies to HIV-1. Finally, the immune complex transfer enzyme immunoassay has been recently improved so as to be performed within shorter periods of time (2-3 hr) with higher sensitivity, and testing many samples has become easy.

Acquired Immunodeficiency Syndrome↗

A capillary electrophoresis laser-induced fluorescence method for analysis of potato glycoalkaloids based on a solution-phase immunoassay. 1. Separation and quantification of immunoassay products.

Solution-phase immunoassays are typically faster and more precise than ELISAs. This research developed a solution-phase for the immunoassay of potato glycoalkaloids (GAs) based on quantification by capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection. Solanidine coupled to 4'-(aminomethyl)fluorescein and a polyclonal antibody solution were used as the immunoreagents. Unbound fluorescent solanidine was detected by CE-LIF (excitation 488 nm, emission 520 nm). Optimum resolution of immunoassay products was achieved with a buffer consisting of 50 mM phosphate, 10% (v/v) methanol, and 1.5 mM SDS, pH 7.5. A plot of signal vs log [GA] produced a sigmoidal curve typical of immunoassays. Analysis of extracts of sprouted Yukon Gold potato tubers and nonsprouted Yukon Gold tubers resulted in total [GA] of 98 microg/g (RSD 9%) and 55 microg/g (RSD 9%), respectively. The findings indicated that CE-LIF coupled with a solution-phase immunoassay can be used to quantify total GA in potatoes.

Carbohydrate Sequence↗

Monoclonal antibodies based sandwich erythro-immunoassay and 'dot' enzyme immunoassay for human chorionic gonadotropin in urine.

Two simple solid-phase sandwich immunoassays for human chorionic gonadotropin (hCG) employing monoclonal antibodies have been described. One is a sandwich erythro-immunoassay employing V-shaped well microtitration plates coated with monoclonal anti-beta-hCG antibody and monoclonal anti-alpha-hCG antibody labelled sheep erythrocytes. The second is a 'dot' enzyme immuno-assay employing dip-stick (plastic strips pasted with nitrocellulose pads) coated with monoclonal anti-beta-hCG antibody. Anti-alpha-hCG monoclonal-alkaline phosphatase conjugate was used to reveal hCG bound to solid surface. The assays can be performed by 'one-step' or 'two-step' procedures. Erythro-immunoassay as well as 'dot' enzyme immunoassay was able to detect in urine as low as 10 mIU hCG/ml. A good correlation was observed between the values obtained by these two methods as well as 'two-step' sandwich enzyme immunoassay on 47 urine samples.

Antibodies, Monoclonal↗

[Fluorescence polarization immunoassay and microparticle enzyme immunoassay].

We describe a new clinical laboratory instrument, the Abbott AxSYM, which provides random- and continuous-access testing for immunoassays, 20 onboard reagents, primary tube sampling, and a throughput of 80 to 120 tests per hour. The AxSYM incorporates three separate analytical technologies for processing immunoassays: microparticle enzyme immunoassay, fluorescence polarization immunoassay, and a novel technology known as ion-capture immunoassay. The system incorporates both common and technology-specific subsystems controlled by a real-time software scheduling processor. Tests can be processed in one- or two-step sandwich or competitive formats, with variable pipetting steps, incubation periods, optical read formats, and wash sequences. Menu capabilities include test for hepatitis, retrovirus, tumor markers, fertility markers, thyroid functions, and therapeutic drugs. The time to first result is 15 approximately 25 min for most routine assay and < or = 15 min for stat assays (i.e., creatine kinase MB isoenzyme, human chorionic gonadotropin beta subunit, and therapeutic drugs). AxSYM assay performance for 23 assays was comparable with that of the Abbott IMx and TDx analyzers; specimen correlation data had correlation from 0.99 to 1.10. Within-run imprecision (CV) was 1.5% to 11.4%, with most assays (19 of 23) demonstrating CVs < or = 8.0%.

Fluorescence Polarization Immunoassay↗

Novel and sensitive noncompetitive enzyme immunoassay (hetero-two-site enzyme immunoassay) for alpha-human atrial natriuretic peptide in plasma.

A novel and sensitive noncompetitive enzyme immunoassay (hetero-two-site enzyme immunoassay) for alpha-human atrial natriuretic peptide (alpha-hANP) in plasma, which uses only one monoclonal IgG for the ring structure of alpha-hANP, is described. Plasma was filtered through polysaccharide membrane to separate peptides from proteins. The plasma filtrate was incubated with N-hydroxysuccinimidobiotin to biotinylate alpha-hANP and subsequently with a polystyrene ball coated with monoclonal IgG for the ring structure of alpha-hANP to trap biotinylated alpha-hANP. The polystyrene ball was washed to eliminate unreacted N-hydroxysuccinimidobiotin and other biotinylated substances, and biotinylated alpha-hANP was eluted from the polystyrene ball with HCl. The eluate was neutralized and incubated with horseradish peroxidase-labeled antibody IgG for the ring structure of alpha-hANP and subsequently with two streptavidin-coated polystyrene balls. Peroxidase activity bound to the streptavidin-coated polystyrene balls was assayed by fluorometry. The detection limit of alpha-hANP was 20 amol, and the assay range of plasma alpha-hANP was 0.8-1,200 ng/L using 100 microliters of plasma filtrates corresponding to 75 microliters of plasma. Plasma levels of hANP in healthy subjects were 9.8-21.5 ng/L. These values were significantly lower than those measured by a two-site enzyme immunoassay probably due to the presence of alpha-hANPs lacking some N-terminal amino acids, which were as reactive as alpha-hANP in the two-site enzyme immunoassay but less reactive in the hetero-two-site enzyme immunoassay.

Adult↗