Search PubMedSearch

SEARCH · Search PubMed

Results for “Error minimization”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

185 recordsLinked to original sources

Robust error-minimization in the genetic code across physicochemical metrics and variant codes: A graph-theoretic analysis in GF(2)6.

The standard genetic code reduces the impact of point mutations, but the robustness of this property across physicochemical metrics, naturally occurring variant codes, and codon-reassignment mechanisms remains incompletely quantified. Embedding the 64 codons in GF(2)6 represents the hypercube Q6 as a coordinate-dependent subgraph of the encoding-independent single-nucleotide mutation graph H(3,4), and enables continuous &#x3c1;-interpolation between the two. Under a quartet-pattern shuffle null (n=10,000), the standard code is significantly low-cost across four established, code-independent physicochemical distance metrics with partially overlapping content (Grant ham p=0.0062; Miyata p<0.001; Woese polar requirement p=0.003; Kyte-Doolittle hydropathy p=0.001), and the signal strengthens monotonically as &#x3c1; moves Q6&#x2192;H(3,4). A structure-aware sensitivity analysis under the alignment-derived ProtSub matrix (Jia & Jernigan 2021) yields the most extreme percentile of any measure tested (p=0.0004; all five p-values pass Bonferroni at &#x3b1;=0.05). Across the 27 NCBI translation tables, near-optimality is preserved: 11 of 12 informative-distance variants retain top-5% placement after BH-FDR correction. Natural codon reassignments avoid disrupting codon-family connectivity: under the encoding-independent H(3,4) adjacency, observed events are topology-breaking at relative risk 0.32 versus the candidate landscape (permutation p&#x2264;10-4). The H(3,4) result is stable by construction; the Q6 decomposition is representation-specific and fails to show depletion under 8 of 24 base-to-bit encodings, so we report H(3,4) as the primary test and Q6 as a sensitivity. Event-level conditional-logit modelling shows that topology avoidance and local physicochemical cost provide complementary, only weakly correlated signal (rs=0.15), and that topology adds explanatory value beyond physicochemistry under both Q6 and encoding-independent H(3,4) adjacency. Retrospective reanalysis of nine genome-recoding datasets is consistent with codon-family topology operating as an evolutionary-trajectory constraint distinct from acute engineering fitness. The contribution is the second axis: code evolution is jointly constrained by physicochemical smoothness and codon-family topological integrity, and these two constraints are partly independent.

Codon reassignment

Test-retest reliability of spatiotemporal, kinematic, and kinetic measures in marker-based 3D gait analysis: A systematic review.

BACKGROUND: Marker-based 3D gait analysis (3DGA) is widely used to quantify impairments and evaluate treatment effects. For longitudinal clinical interpretation, clinicians and researchers need reference values for inter-session measurement error. For this purpose, this systematic review synthesized Standard Error of Measurement (SEM) values for spatiotemporal, kinematic, and kinetic (moments) outcomes obtained from marker-based 3DGA studies. METHODS: PubMed and Scopus were searched (final search: 11 December 2025). Studies reporting inter-session test-retest SEM and/or MDC for steady-state overground or treadmill walking using marker-based motion capture were included. Two authors screened records and appraised methodological/reporting quality using a custom tool informed by COSMIN, GRRAS, and biomechanics-specific items. Due to heterogeneity, results were synthesized descriptively using study-level median SEM values, stratified by joint, plane, population (healthy, pathological, single subgroups), and walking condition. Minimal Detectable Change (MDC) values were computed for all available data. RESULTS: Thirty-four studies (762 participants, 44.2% females) were included, with substantially more evidence for overground than treadmill walking. Overground spatiotemporal outcomes showed low errors (walking speed SEM of 0.06 m/s; timing typically &#x2264;0.03 s; spatial parameters generally &#x2264;0.03 m). For joint kinematics during overground walking, median SEMs were 2.4&#xb0; (sagittal), 1.9&#xb0; (frontal), and 3.3&#xb0; (transverse). The corresponding joint-kinetic SEMs were approximately 0.06, 0.04, and 0.03 Nm/kg, respectively. Treadmill data followed similar patterns. SIGNIFICANCE: Marker-based 3DGA allows for accurate assessment of spatiotemporal, kinematic, and kinetic gait features. We provided detailed SEM/MDC lookup tables to support clinical decision-making. Results further offer a benchmark for validating emerging gait assessment technologies (e.g., markerless systems) against realistic limits of marker-based 3DGA.

Humans

Standardized visual overlays enhance laparoscopic instruction: A mixed-methods evaluation.

Effective communication during laparoscopic procedures is frequently undermined by spatial disorientation and inconsistent terminology between instructors and trainees. This study examined whether standardized visual overlays on endoscopic monitors could enhance communication and learning. We conducted a three-phase mixed-methods study: qualitative observation of 20 laparoscopic teaching cases; a randomized trial of 63 second-year medical students assigned to control, clock, or alphanumeric grid (AG) overlays during three trials of a standardized transfer task; and intraoperative implementation in 44 cases (30 AG, 14 clock) with post-case surveys and qualitative feedback. In simulation, the clock overlay produced the fastest completion times, whereas the AG yielded the lowest error scores, and both overlays outperformed the control. Intraoperatively, the AG was rated higher than the clock for communication clarity, spatial orientation, perceived operative efficiency, and trainee confidence. Standardized visual overlays, particularly the AG, appear to support intraoperative teaching by providing a shared spatial frame of reference.

Laparoscopy

A framework for delivering real-time, instrument-relative navigation in transoral robotic surgery.

Transoral robotic surgery (TORS) is a minimally invasive, inside-out technique that, compared with traditional open approaches, provides fewer post-operative complications, shorter hospital stays, and improved survival for early-stage head and neck cancer. However, TORS is limited by its steep learning curve and poor visualization of deep tumor margins. This randomized crossover study evaluated a surgical navigation system's potential to enhance accuracy and user experience with real-time, instrument-relative feedback. Seven Teflon beads (d&#x2009;=&#x2009;2.381&#xa0;mm) were embedded at the tongue base of a porcine pharynx-and-larynx model. Tongue blade compression and retraction were applied to the model to mimic intraoperative tissue deformation, reproducing the anatomical shifts that occur relative to preoperative imaging. Eight participants used the da Vinci Surgical system to localize the beads by placing pins under two conditions: (a) preoperative computed tomography with no navigation; (b) model-based visual navigation with quantitative instrument-to-target metrics. Surgical accuracy was determined by calculating the target localization error (TLE, pin-to-bead Euclidean distance) and the angular error (AE, pin axis trajectory to bead). Accounting for training level and bead depth, surgical navigation reduced TLE by 5.44&#xa0;mm (95% CI, 4.02-6.86&#xa0;mm; p&#x2009;=&#x2009;2.00e-11) and AE by 8.47 degrees (95% CI, 6.21-10.72 degrees; p&#x2009;=&#x2009;5.17e-11). Impressions of the system were generally favorable using a 5-point Likert survey and task duration (p&#x2009;=&#x2009;0.26) or cognitive workload via the NASA-Task Load Index (p&#x2009;=&#x2009;0.22) were not significantly affected. The navigation system demonstrated translational promise, offering improved target localization accuracy and more consistent performance across experience levels, two critical determinants of surgical quality in TORS.

Robotic Surgical Procedures

Pictographs: feasibility and acceptability of a novel method of newborn identification to reduce wrong-patient errors in the NICU.

Wrong-patient errors cause serious harm in newborns. These errors involve ordering and administering tests, procedures, medications, and breast milk to an unintended patient. Newborns receiving care in neonatal intensive care units (NICUs) are at particularly high risk. Although more distinct newborn naming conventions as recommended by the Joint Commission significantly reduce wrong-patient orders, name similarities among multiple-birth infants and truncation of differentiating information in some electronic health record (EHR) systems contribute to this persistent increased risk. Accordingly, novel newborn identifiers are urgently needed. We propose Pictographs&#xa0;-&#xa0;images that are appealing, recognizable, and appropriate&#xa0;-&#xa0;to serve as visual identifiers for newborns in NICUs. Pictographs are selected by caregivers, uploaded into the EHR, and displayed at bedside. As part of a multicenter randomized controlled trial assessing effectiveness of Pictographs to prevent wrong-patient order errors, we initially evaluated feasibility and acceptability of Pictographs at two study sites. Pictographs as novel visual identifiers for newborns in the NICU were generally well received by caregivers and clinicians, and the vast majority of caregivers selected a Pictograph for their infant(s), which was posted at the bedside and uploaded into the EHR. Ordering clinicians&#xa0;-&#xa0;the primary target of the intervention to prevent wrong-patient errors&#xa0;-&#xa0;recognized the potential for Pictographs to provide a visual cue when placing orders, particularly for multiple-birth infants. Here, we describe the rationale, implementation, framework, feasibility, usefulness, and acceptability of Pictographs among key stakeholders. If found effective for preventing wrong-patient errors, Pictographs could be adopted as a patient safety solution in hospitals worldwide.

Female

Family-Wise Error Rate Control in Clinical Trials With Overlapping Populations.

We consider clinical trials with multiple, overlapping patient populations that test multiple treatment policies specifically tailored to these populations. Such designs may lead to multiplicity issues, as false statements will affect several populations. For type I error control, often the family-wise error rate (FWER) is controlled, which is the probability to reject at least one true null hypothesis. If the joint distribution of the test statistics is known, the FWER level can be exhausted by determining critical values or adjusted-levels. The adjustment is typically done under the common ANOVA assumptions. However, the performed tests are then only valid under the rather strong assumption of homogeneous null effects, that is, when the null hypothesis applies to all subpopulations and their intersections. We show that under cancelling null effects, when heterogeneous effects cancel out in some or all subpopulations, this procedure does not provide FWER control. We also suggest different alternatives and compare them in terms of FWER control and their power.

Humans

An Update on Inborn Errors of V(D)J Recombination.

V(D)J recombination is the fundamental process by which developing T and B lymphocytes generate diverse antigen receptors, enabling adaptive immunity. This tightly regulated program operates exclusively in lymphoid precursors during G1 phase and depends on the lymphocyte-specific RAG1-RAG2 recombinase to introduce programmed DNA double-strand breaks at recombination signal sequences, followed by repair through the classical nonhomologous end joining (c-NHEJ) pathway. Disruption of any step in this molecular choreography compromises antigen receptor diversity and underlies a spectrum of inborn errors of immunity (IEIs), ranging from severe combined immunodeficiency (SCID) to immune dysregulation with autoimmunity and granulomatous disease. In this review, we place disorders of V(D)J recombination within the broader framework of T-cell development, detailing the temporal waves of recombinase activity, chromatin accessibility, and DNA damage responses that guide thymocyte differentiation. We discuss pathogenic variants affecting the cleavage phase [RAG1, RAG2, and the recently identified RAG cochaperone NudC domain-containing 3 (NUDCD3)], end processing (ARTEMIS), ligation and repair (LIG4, XLF, XRCC4, PRKDC), and genome surveillance pathways (ATM, MRN complex, RNF168), highlighting genotype-phenotype correlations and mechanisms driving immune deficiency and dysregulation. We briefly review recent diagnostic advances, including newborn screening using T-cell receptor excision circles, repertoire sequencing, and functional assays, alongside current therapeutic strategies. Finally, we outline key unanswered questions and argue that continued integration of clinical observation with molecular discovery is essential to improve outcomes and deepen understanding of adaptive immune development.

Humans

Beyond Photometric Consistency: Addressing Loss Insensitivity to Depth Noise in Endoscopic Estimation via Error Calibration.

Self-supervised monocular depth estimation in endoscopy is fundamentally constrained by the ill-posed nature of photometric supervision. In this work, we identify a critical yet overlooked cause of this ambiguity: the inherent insensitivity of photometric loss to depth noise. To overcome this intrinsic limitation, we propose Depth Error Calibration Learning (DECL), a two-stage framework that suppresses prediction variance and mitigates residual errors in self-supervised depth estimation. In Stage I (Variance Reduction), a cyclic depth generation strategy produces multiple depth hypotheses for the input image. The per-pixel empirical variance is quantified and integrated into a dedicated variance loss term, which penalizes inconsistent predictions and encourages the network to generate more stable and reliable depth estimates. In Stage II (Bias Calibration), an image-conditioned diffusion model refines the Stage-I depth prior and mitigates structured residuals through iterative denoising, thereby improving geometric accuracy and global consistency. Extensive experiments on three public endoscopic datasets demonstrate that DECL achieves consistent improvements over representative self-supervised monocular depth estimation methods under the evaluated protocols. Moreover, ablation studies on two representative backbones indicate that DECL is not restricted to a single network implementation, while broader validation on additional backbone families remains necessary. The source code is publicly available at https://github.com/DavidLuBit/EndoDenoising.

Journal Article

Angiotensin II regulates anxiety and social-affective top-down and bottom-up attention control in a sex-dependent manner.

BACKGROUND: The renin-angiotensin system (RAS) has been increasingly recognized as potent modulator of cognitive and affective functions, with angiotensin II type 1 receptor (AT1R) antagonists emerging as repurposing candidate for anxiety and stress-related disorders. However, it remains unclear whether transient AT1R blockade modulates emotional attentional control and whether these effects are sex-dependent. METHODS: We conducted a preregistered, randomized, double-blind, placebo-controlled pharmacological eye-tracking study in 79 healthy adults (males and females) and determined effects of transient AT1R blockade via losartan (50&#xa0;mg) on emotional attention control using a validated anti-saccade paradigm with social (emotional faces) and non-social stimuli. Treatment effects on state anxiety and oculomotor responses were characterized using traditional metrics and a novel trial-history informed dynamic control framework. RESULTS: Losartan reduced state anxiety irrespective of sex but induced sexually dimorphic effects on attentional control. In females, losartan enhanced performance by reducing endpoint error without altering latency. Conversely, in males, losartan increased endpoint error and prolonged latency of the first correct saccade. Trial-history analyses revealed losartan reduced error probabilities following errors and repeat trials in both sexes. Yet, following correct trials, females receiving losartan maintained lower error probabilities, while males exhibited higher errors, potentially reflecting failure to disengage from effortful control. CONCLUSIONS: The RAS modulates anxiety and attentional control, the latter sex-dependently. AT1R blockade reconfigures attentional processing and adaptive control, suggesting sex-specific therapeutic potential in disorders characterized by excessive anxiety and attentional dysregulation. CLINICAL TRIALS REGISTRATION: ClinicalTrials.gov; https://clinicaltrials.gov/;NCT06329050.

Humans

Application of causal discovery of factors driving dissolved oxygen in estuarine environments.

Dissolved oxygen (DO) concentrations in estuarine bottom waters are a manifestation of multiple, interacting physical and biogeochemical processes, yet identifying their independent contributions remains challenging. Here, we analyze monthly water quality monitoring data from eight stations across Long Island Sound from 1994 to 2022 using a causal discovery framework (PCMCI+) and transformation of forcing variables. Our goal is to identify and isolate variables that causally influence bottom DO and improve predictive models by minimizing overfitting and multicollinearity. PCMCI+ reveals surface-layer temperature as the most important and consistent negative driver of bottom DO, followed by stratification. Wind events exhibit only brief relief by advection and mixing, while river discharge shows no direct causal link to DO, making it less influential than previously thought. Biogeochemical variables, including chlorophyll-a (Chl-a), nitrate and nitrite, and particulate carbon, influence DO through both contemporaneous and time-lagged pathways, often with signs that shift depending on the process. The derived models were evaluated by comparing skill scores, mean squared error, and Akaike Information Criterion. Both model types perform well, with coefficient of determination values exceeding 0.90 at multiple stations using only 3-5 predictors. Our analysis reveals that the best causal predictors are surface-layer temperature, stratification, Chl-a, and particle carbon. This approach provides a scalable framework for improving prediction models and understanding the mechanistic links that control the seasonal variability of DO in estuarine systems.

Estuaries

Temporal redistribution of control reveals age-related differences in task switching at the level of preparation.

Task-switching studies often report minimal age-related differences in switch costs, leading to the conclusion that switching-related control processes are relatively preserved in aging. However, this conclusion is based on paradigms that confound preparatory and execution processes. This study examined whether age-related differences in semantic task-set reconfiguration may be underestimated due to this confound. In Experiment 1 (36 young and 30 older adults), participants performed an externally paced task-switching paradigm without control over preparation. In Experiment 2 (28 young and 28 older adults), a self-paced paradigm allowed participants to initiate stimulus onset, enabling measurement of preparation time. Across both experiments, reaction time (RT) and error rate (ER) showed reliable age effects but no interactions between age and condition, whereas switching-related condition effects varied across measures and experiments. The expression of switching-related costs differed across measures and task structures. Local switch costs were expressed in ER in Experiment 1 but in RT in Experiment 2. Global switch costs (all-switch vs. all-repeat) were observed in execution measures only in Experiment 1. In Experiment 2, preparation time showed reliable mixing, local, and global switching effects, with age-related amplification emerging specifically for global switching. These findings indicate that switching-related costs are redistributed across processing stages and behavioral measures. The results suggest that age-related modulation of semantic task-set reconfiguration may emerge more clearly during preparation than task execution, particularly under continuous switching demands. Preparation time is interpreted cautiously as reflecting participant-regulated preparatory processes rather than a pure measure of preparation efficiency.

Humans

Pilot Distractions and Interruptions in Airlines: Ranking of Sources by Analytic Hierarchy Process.

ObjectiveThis work establishes a methodological framework for sources of pilot distraction and interruptions in a structured model that can be used as a tool for cockpit design/procedure assessment.BackgroundPilots must complete complex tasks, and distractions can impair performance and lead to errors that can cause aircraft accidents. Although various cockpit distractors are examined individually, there is no integrated approach.MethodDistraction and interruption sources were identified through a literature review and confirmed/extended by interviews with airline pilots. Associated weights were determined through pairwise comparisons, yielding a hierarchical model using the Analytic Hierarchy Process.Results26 sources of pilot distraction and interruptions were quantified and categorized into four categories: communication, head-down time, responding to abnormal conditions & unexpected situations, and searching for traffic.ConclusionA taxonomic structure for assessment is achieved with the top 5 sources identified as communications, technical interruptions, experience in type, environmental factors, operational irregularities, and airspace high terrain, accounting for 63.07%.ApplicationThe structured system is a flexible assessment scale that provides a taxonomic framework for airline risk management, supports future research, and cockpit design efforts.

Humans

Civil liability in oral & maxillofacial surgery: &#x391; systematic review.

Maxillofacial surgery is a surgical specialty with anatomical, functional, and aesthetic requirements, which makes it a field at increased risk of medical negligence and subsequent legal claims. The review was conducted in accordance with the PRISMA guidelines and used international medical and legal databases. Studies that analyzed court decisions, insurance claims, or recorded compensation data related to maxillofacial surgery were included. The extracted data included, among others, the year and country of publication, the causes of action, and the amounts of financial compensation. Most lawsuits originate from countries with developed medical liability systems, primarily the United States and the United Kingdom, and there has been an increasing trend in publications over the last two decades. The most common causes of lawsuits involve nerve injuries, delayed or incorrect diagnoses, technical errors during surgery, and inadequate informed consent. The amounts of compensation vary widely, from lower five-digit amounts in milder cases to particularly high amounts in cases of permanent functional or aesthetic damage, placing a significant overall financial burden on health systems. Medical negligence in maxillofacial surgery constitutes an important forensic and socioeconomic issue. Understanding the causes of lawsuits and their financial consequences can help improve clinical practice, inform patients, and prevent legal disputes.

Humans

Premature closure underlies bias in medical diagnosis in students: A randomised controlled experiment.

OBJECTIVE: The purpose of the study reported in this article was to shed light on the cognitive mechanism mediating between biasing information and diagnostic error. The literature suggests at least two different hypotheses: premature closure leading biased participants to spend less time on diagnosis or increased competition between diagnostic hypotheses. The latter hypothesis predicts that biased participants would spend more time reaching a diagnosis. METHOD: Using the salient distracting findings (SDF) experimental paradigm, we biased 58 fourth-year medical students while diagnosing 12 clinical vignettes in a within-group incomplete block design under three conditions: cases presented without SDF, with SDF at the beginning and with SDF at the end. For each of these conditions, diagnostic accuracy, the number of SDF-related mistakes and time per word needed to process the case were recorded. The data were analysed using linear mixed modelling. Estimated marginal mean scores were reported. RESULTS: Participants confronted with salient distracting features (SDFs) at the beginning of a clinical case demonstrated significantly lower diagnostic accuracy (mean 0.11) compared with the No-SDF condition (0.27), representing a 61% reduction (F2,693&#x2009;=&#x2009;11.995, p&#x2009;<&#x2009;0.001), and made more SDF-related mistakes (F2, 693&#x2009;=&#x2009;16.395, p&#x2009;<&#x2009;0.001). When SDFs were presented at the end of the case, diagnostic accuracy was also reduced (mean 0.17; 36% reduction), but processing time did not differ from the No-SDF condition. Only early presentation of SDFs was associated with reduced processing time per word (F2,636&#x2009;=&#x2009;4.799, p&#x2009;<&#x2009;0.01), consistent with premature closure. CONCLUSION: These findings demonstrate that biasing information increases diagnostic error in medical students and that only early bias is associated with reduced information processing. The data do not support the competition hypothesis for early bias, as processing time did not increase under biasing conditions. Premature closure can therefore be directly observed rather than inferred, inviting further research.

Humans

The influence of organizational culture on medication safety practices and associated risk factors in the community setting: A systematic review.

BACKGROUND: Increasing attention has been given to the role of organizational culture in influencing medication safety practices across healthcare settings. The lack of widely accepted standardized instrumentation makes operational measurement of organizational culture and medication safety challenging. The purpose of this systematic review was to examine the impact of organizational culture on medication safety within community healthcare settings. METHODS: MEDLINE, CINAHL, Scopus, and Nursing & Allied Health were searched in August 2025 using keywords, subject terms, field codes, and Boolean operators to identify papers relevant to the review question; bibliographies of included studies were also reviewed. Screening and full-text review were completed independently by two reviewers with a third to adjudicate conflicts. The Critical Appraisal Skills Programme was used for quality assessment. The PRISMA statement guided the development and implementation of the review. RESULTS: Thirteen articles were included representing various community settings. Most studies reported on untoward medication events, but few measured systematically collected safety data before and after an intervention. Organizational culture was seldom defined or operationalized. Most studies were methodologically sound, but the overall level of evidence was weak to moderate. CONCLUSION: Organizational culture influences medication safety through aspects such as communication channels, teamwork, training, and an environment that allows error and near-miss reporting. Few studies explicitly evaluate the causal impact of culture interventions on measurable medication safety outcomes in community healthcare settings. Further research should incorporate standardized measurement tools and intervention-based, pre-post designs to better understand how organizational culture influences medication safety in community healthcare settings.

Organizational Culture

Sitosterolemia: evolving strategies for earlier diagnosis.

PURPOSE OF REVIEW: Sitosterolemia is a rare autosomal recessive lipid disorder caused by biallelic pathogenic variants in ABCG5 or ABCG8 , resulting in excessive intestinal absorption and impaired biliary excretion of plant sterols. Although historically considered exceptionally rare, recent genetic studies suggest the disorder is substantially underdiagnosed, with marked phenotypic heterogeneity ranging from xanthomas and premature atherosclerosis to hematologic abnormalities, and frequently mimics familial hypercholesterolemia. This review summarizes recent advances in the clinical, biological, and genetic diagnosis of sitosterolemia, with a focus on strategies that may facilitate earlier detection. RECENT FINDINGS: Phytosterol quantification, particularly sitosterol, campesterol, and stigmasterol, remains indispensable for accurate diagnosis. Hematologic abnormalities, including hemolytic anemia, stomatocytosis, and macrothrombocytopenia, are increasingly recognized as valuable diagnostic clues complementing the biochemical approach. Expanded variant catalogs for ABCG5/ABCG8 and genome-wide association studies have revealed potentially polygenic contributions to phytosterol metabolism extending beyond these two genes. However, no specific guidelines have yet been established for cascade screening. SUMMARY: Earlier diagnosis requires integration of clinical, biochemical, hematologic, and genetic data. Plasma phytosterol measurement remains the diagnostic cornerstone. Improved disease awareness, broader access to sterol testing, and expanded genetic screening may reduce diagnostic delays and enable timely management, including ezetimibe and dietary phytosterol restriction.

Humans

Effects of Dynamic Neck Sensorimotor Biofeedback Training in Individuals With Mechanical Neck Pain: A Pilot Randomized Controlled Trial.

Mechanical neck pain (MNP) is commonly accompanied by pain-related functional limitations, sensorimotor disturbances, and fear of movement, which together may contribute to persistent disability. This preliminary randomized controlled trial study investigated the short-term effects of dynamic neck sensorimotor-based biofeedback training in individuals with MNP. 20 MNP patients from outpatient clinics were assigned to a biofeedback training group or a control group. The training group underwent dynamic biofeedback exercises twice weekly for 2&#xa0;weeks, whereas the control group performed repeated cervical movements without biofeedback. Outcomes included cervical kinematics as repositioning errors (RPE), movement units (MU), maximal range of motion (ROM), and subjective measures, including pain intensity, Neck Disability Index (NDI), and Fear-Avoidance Beliefs Questionnaire (FABQ). All participants completed post-intervention assessments; adherence in the training group was 100%, with no missing data and no adverse events reported. Within the biofeedback training group, participants receiving biofeedback training demonstrated greater improvements in cervical repositioning accuracy during flexion (51.95%, p&#xa0;=&#xa0;0.04) and extension (46.67%, p&#xa0;=&#xa0;0.02), along with reductions in fear-avoidance beliefs related to physical activity and work (p&#xa0;<&#xa0;0.05); these changes were less apparent in the active control group. Exploratory regression analyses suggested associations between improvements in repositioning accuracy and pain reduction, and between increased cervical range of motion and improvements in fear-avoidance beliefs related to physical activity. These pilot findings suggest that dynamic sensorimotor biofeedback training may improve proprioceptive acuity and fear-avoidance beliefs in individuals with MNP, supporting further evaluation in an adequately powered randomized trial.

Humans

Associations between smart infusion pump-electronic health record interoperability and healthcare outcomes: A systematic review.

OBJECTIVE: This study synthesized available evidence on the associations between smart infusion pump-electronic health record (EHR) interoperability and healthcare outcomes. METHODS: A systematic review of PubMed, CINAHL, Embase, and Scopus databases identified 901 records, which were imported into Rayyan&#xae; for duplicate removal, independent screening by three reviewers, and resolution of discrepancies. Eligible studies were peer-reviewed, data-driven, and reported associations between smart infusion pump-EHR interoperability and healthcare outcomes. Studies focused solely on technical validation or interoperability prototypes were excluded. A backward citation search identified additional studies. Two reviewers independently extracted and cross-validated study characteristics using standardized templates. Methodological quality was assessed with the Joanna Briggs Institute Critical Appraisal Tools. RESULTS: Twenty records of 14 full-text studies and 6 conference proceedings were included. Most records reported positive associations between smart infusion pump-EHR interoperability and outcomes related to safety (e.g., medication administration errors, safety-reported events, pump alerts, and compliance with interoperability and drug library), operational efficiency (e.g., programming and documentation time and technical issues), financial performance (e.g., charges captured, and cost avoided), and user experience domains. Most studies used observational designs, reflecting real-world interoperability implementations, where controlling confounding factors is challenging. Limited reporting of baseline characteristics, pump type, and sample sizes limited comparability across studies. CONCLUSIONS: Smart infusion pump-EHR interoperability was associated with improvements in patient safety, efficiency, charge capture, and user experience, with variable findings across studies. Future research should use rigorous methodologies and standardized measures, examine relationships across outcome domains, assess limitations of pump-EHR interoperability, and evaluate underexplored outcomes, including team communication, cognitive workload, and AI-enabled pumps. IMPLICATIONS FOR CLINICAL PRACTICE: Interoperability should be viewed as a component of a broader sociotechnical system, in which technology, user, workflow, clinical content, and organizational practices collectively determine overall effectiveness.

Humans