Search PubMedSearch

PubMed · 42444565

Pictographs: feasibility and acceptability of a novel method of newborn identification to reduce wrong-patient errors in the NICU.

Abstract

Wrong-patient errors cause serious harm in newborns. These errors involve ordering and administering tests, procedures, medications, and breast milk to an unintended patient. Newborns receiving care in neonatal intensive care units (NICUs) are at particularly high risk. Although more distinct newborn naming conventions as recommended by the Joint Commission significantly reduce wrong-patient orders, name similarities among multiple-birth infants and truncation of differentiating information in some electronic health record (EHR) systems contribute to this persistent increased risk. Accordingly, novel newborn identifiers are urgently needed. We propose Pictographs - images that are appealing, recognizable, and appropriate - to serve as visual identifiers for newborns in NICUs. Pictographs are selected by caregivers, uploaded into the EHR, and displayed at bedside. As part of a multicenter randomized controlled trial assessing effectiveness of Pictographs to prevent wrong-patient order errors, we initially evaluated feasibility and acceptability of Pictographs at two study sites. Pictographs as novel visual identifiers for newborns in the NICU were generally well received by caregivers and clinicians, and the vast majority of caregivers selected a Pictograph for their infant(s), which was posted at the bedside and uploaded into the EHR. Ordering clinicians - the primary target of the intervention to prevent wrong-patient errors - recognized the potential for Pictographs to provide a visual cue when placing orders, particularly for multiple-birth infants. Here, we describe the rationale, implementation, framework, feasibility, usefulness, and acceptability of Pictographs among key stakeholders. If found effective for preventing wrong-patient errors, Pictographs could be adopted as a patient safety solution in hospitals worldwide.

Explore related subjects

Keep this discovery

BibTeXRIS

Jason S Adelman, Jo R Applebaum, Eileen Carter, James M Kim, Katie R Forman, Michelle Gontasz, Maureen Gilmore, Hojjat Salmasian, Carmina Erdei, Anika S Naidu, Emma J Weatherford, Benjamin L Ranard, I-Fong Sun Lehman, Allen R Chen, Dena Goffman, John Babineau, Sandhya Brachio. 2026-07-15. Pictographs: feasibility and acceptability of a novel method of newborn identification to reduce wrong-patient errors in the NICU.. https://doi.org/10.1515/jpm-2026-0027

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

Compound muscle action potential amplitudes in newborn screen positive spinal muscular atrophy.

OBJECTIVE: To evaluate the utility of compound muscle action potential (CMAP) amplitudes as biomarkers of disease severity in newborn screening (NBS)-positive infants with spinal muscular atrophy (SMA). METHODS: We conducted a retrospective review of 21 infants identified through SMA NBS (11 with 2 SMN2 copies and 10 with 3 SMN2 copies). Baseline and serial right median, ulnar, and fibular motor nerve CMAP amplitudes (millivolts, mV) were obtained during the study. Functional outcomes were assessed using the Children's Hospital of Philadelphia Infant Test of Neuromuscular Disorders (CHOP-INTEND). RESULTS: At baseline, infants with 2 SMN2 copies demonstrated significantly lower median, ulnar, and fibular CMAP amplitudes compared with infants with 3 SMN2 copies (p&#xa0;<&#xa0;0.05). In contrast, baseline CHOP-INTEND scores did not differ significantly between the two groups. Prior to genetic confirmation, a right median CMAP amplitude&#xa0;&#x2265;3.2&#xa0;mV predicted&#xa0;&#x2265;3 SMN2 copies. Following treatment, right median and fibular CMAP amplitudes demonstrated significant improvement over time, including in analyses accounting for SMN2 copies number. CONCLUSION: CMAP amplitudes obtained from multiple upper- and lower-extremity motor nerves provided objective electrophysiological measures that distinguished infants with two versus three SMN2 copies, despite similar baseline CHOP-INTEND scores. Furthermore, CMAP abnormalities were detectable in some cases before confirmatory genetic testing results became available. Serial CMAP measurements demonstrated significant longitudinal changes following treatment, whereas functional assessments approached ceiling values, supporting the potential value of electrophysiological monitoring in the era of disease-modifying therapies. SIGNIFICANCE: CMAP assessment is a useful adjunct in the evaluation of infants identified through SMA NBS.

Humans

Comparison between the thoracoabdominal rebalancing (TAR) method and the slow expiratory flow acceleration (SEFA) technique in preterm newborns: protocol for a randomised controlled clinical trial.

INTRODUCTION: Preterm newborns (PTNB) present respiratory immaturity and increased susceptibility to muscle fatigue. The thoracoabdominal rebalancing (TAR) method is a physiotherapeutic intervention developed in Brazil that aims to reorganise the synergy of the thoracoabdominal muscles and reduce the effort of the respiratory muscles, a benefit that is particularly important for PTNB; however, the evidence regarding its effectiveness in this population remains inconclusive. Therefore, this study aims to compare the short-term effects of the TAR method and the slow expiratory flow acceleration (SEFA) technique in improving respiratory distress and peripheral oxygen saturation (SpO2) in PTNB admitted to neonatal intensive care unit (NICU). METHODS AND ANALYSIS: The study will be a randomised, controlled, two-arm, parallel-group, single-blind clinical trial. 68 participants will be randomly assigned to one of the two treatment groups. Group 1 will receive four handling techniques of the TAR method for 10&#x2009;min, followed by the rhinopharyngeal retrograde clearance with saline instillation (RRC+I) technique. Group 2 will receive the SEFA technique for 10&#x2009;min, also followed by RRC+I. Primary outcomes are respiratory distress and SpO2. Secondary outcomes are respiratory rate (RR), heart rate (HR), pain, behaviour and diaphragmatic excursion. Assessments will be conducted by a blinded researcher at baseline (T0), immediately after the intervention (T1) and at the 30-minute follow-up (T2). Data will be described using measures of central tendency and dispersion and absolute and relative frequencies. An intention-to-treat analysis will be performed, and intragroup and intergroup comparisons will be assessed using generalised estimating equations (GEE). ETHICS AND DISSEMINATION: The Research Ethics Committee of the Faculty of Health Sciences of Trairi of the Federal University of Rio Grande do Norte approved this study (number 8,055,786). The results will be disseminated through peer-reviewed journal publications, scientific conferences presentations and knowledge translation to the public. TRIAL REGISTRATION NUMBER: This study was registered on Brazilian Registry of Clinical Trials (ReBEC) on 9 January 2026 (RBR-3gbsyc2).

Humans