Search PubMedSearch

SEARCH · Search PubMed

Results for “Equipment and Supplies”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

2,984 recordsLinked to original sources

Discarding Bedside Cart Paper-Packaged Supplies Between Patients: What Evidence Is Required?

BACKGROUND: Discarding paper-packaged sterile supplies from bedside supply carts between patients in pediatric intensive care units (PICUs) is a potential practice to target for environmental stewardship. OBJECTIVES: To determine opinions about this practice, including what evidence should be required to implement and what evidence would be adequate to abandon it. METHODS: A survey was distributed to all pediatric intensivists engaged in multicenter research in Canada and to all PICU nurses at one institution in Canada. RESULTS: The response rate was 75 of 254 (30%). The practice occurred in 54 (72%) of the respondents' units. Ten respondents (13%) agreed the practice was effective in preventing nosocomial infections. Most respondents agreed the practice should be based on empirical evidence, including a combination of improved patient outcomes (n = 57, 76%), rate of contamination of supplies within the supply carts (n = 55, 73%), and survivability of pathogens inoculated onto paper (n = 56, 75%). Most respondents agreed they would be comfortable with a randomized controlled trial (n = 52, 69%) and would support action based on the results (n = 54, 72%). The potential trial outcome most highly ranked was next-patient nosocomial infection with pathogen from the previous patient (n = 23, 31%); this was ranked more often by intensivists (P = .005). Other outcomes highly ranked included next-patient colonization with pathogen from the previous patient (n = 44, 59%) and pathogen detection on supplies within the supply cart (n = 43, 57%). CONCLUSIONS: Most respondents agreed that the practice was not based on empirical evidence, agreed the practice should be based on empirical evidence, and would agree to a randomized trial with patient-important outcomes.

Humans

Insights from expert panels on the EU clinical evaluation consultation procedure.

BACKGROUND: The Clinical Evaluation Consultation Procedure (CECP) under the EU Medical Device Regulation aims to strengthen and harmonize the assessment of high-risk medical devices. This review summarizes early insights from expert panels to support improved clinical evaluation practices. RESEARCH DESIGN AND METHODS: This review analyses 34 expert panel opinions derived from 281 CECP submissions between April 2021 and December 2025. Statements from opinions were systematically extracted, de-duplicated, and grouped into thematic categories, with independent review and validation. The analysis focuses on common challenges found during the consultation procedure of the expert panels on the content of the clinical assessment in relation to clinical evidence, benefit-risk assessment, intended purpose alignment, and post-market clinical follow-up planning. RESULTS: Expert panel findings highlight recurrent issues in the sufficiency, consistency, and transparency of clinical evidence, underscoring the need for improved standardization and clearer guidance. CONCLUSIONS: Strengthening documentation quality and alignment across stakeholders will enhance the robustness, efficiency, and predictability of conformity assessments for high-risk medical devices.

Humans

Review of regulatory requirements for benefit-risk assessment for medical devices: uncovering existing methodologies.

INTRODUCTION: A positive benefit-risk profile is a prerequisite for the market approval of medical devices. However, regulations are often criticized for providing limited information on benefit-risk assessment (BRA) despite growing expectations for quantitative methods. A clearer understanding of regulatory requirements, existing methodologies, and unresolved issues is needed. AREAS COVERED: Relevant regulatory documents referencing BRA for medical devices were systematically identified, with a primary focus on the European regulation followed by screening to extract BRA‑related requirements and any explicitly or implicitly described methods. The findings were analyzed and consolidated by BRA context, type, objective, methodological description, and implementation, thereby establishing a basis for the BRA methodological landscape. EXPERT OPINION: BRA is not a single concept, but a set of context‑dependent assessments across lifecycle of a medical device. BRA within clinical evaluation framed into BRAs of risk management holds a pivotal role and is supported by the most detailed methodological guidance, although BRAs in other contexts are important. A structured overview of existing BRA requirements clarifies their treatment across regulatory documents. By differentiating BRA contexts, types, objectives, and required methodological detail, the analysis supports a more transparent understanding of BRA and helps identify priorities for methodological refinement and interface clarification.

Risk Assessment

An impact assessment of the European medical device regulations implementation - the current status quo.

BACKGROUND: This research aims to assess the current impact of the medical and in-vitro diagnostic devices regulations (MDR/IVDR) on the device industry in the EU, under the lens of postimplementation and the amending regulation, and in advance of the final transition to the IVDR/MDR in the future. RESEARCH DESIGN AND METHODS: A quantitative survey was administered to a diverse cohort of medical device enterprises, ranging from micro to large organizations. RESULTS: The survey indicates that the MDR/IVDR has harmed innovation, leading many manufacturers to seek initial device approval and launch elsewhere before in Europe. There is evidence that some manufacturers have rationalized their existing product portfolios and removed devices from the market as they stated they would in previous industry surveys. The MDR/IVDR has been shown to negatively impact manufacturers, with increased costs related to notified body (NB) fees, maintaining and updating documentation, recertification fees, and hiring additional staff. CONCLUSION: This study provides a current status of the effects of MDR/IVDR on manufacturers and finds that despite amending regulations and other interventions taken by the EU to mitigate regulatory burden, ensure product availability, and address stakeholder concerns, the EU is no longer the market of choice for new products.

Equipment and Supplies

Effect of brewers' yeast or beta-glucan derived from Saccharomyces cerevisiae on breast milk supply following preterm birth: the BLOOM randomised controlled trial.

OBJECTIVE: Breast milk is the optimal source of nutrition for preterm infants; however, low breast milk production is common following a preterm birth. This study aimed to determine if taking brewers' yeast or beta-glucan improves daily expressed breast milk volume. DESIGN: Randomised, blinded, parallel, placebo-controlled trial. SETTING: Three Australian tertiary-level neonatal units. PATIENTS: Mothers with a singleton or twin pregnancy who gave birth at <34 weeks' gestation. INTERVENTIONS: Mothers were randomised within 72 hours of birth into three parallel groups in a 1:1:1 ratio to receive either brewers' yeast, beta-glucan or placebo capsules for 7&#x2009;days. MAIN OUTCOME MEASURE: Total expressed breast milk volume over a 24-hour period on day 7 of intervention. RESULTS: A total of 105 mothers underwent randomisation between August 2022 and April 2024 (36 brewers' yeast, 35 beta-glucan and 34 placebo). The adjusted mean difference in daily expressed breast milk volume was 94&#x2009;mL/day (95%&#x2009;CI -51 mL/day to 239&#x2009;mL/day) between the brewers' yeast and placebo groups and -25&#x2009;mL/day (95%&#x2009;CI -173 mL/day to 123&#x2009;mL/day) between the beta-glucan and placebo groups. Maternal side effects were similar across groups. CONCLUSION: We found no clear effect of short-term administration of brewers' yeast or beta-glucan on breast-milk production following preterm birth; both interventions were well tolerated. Given the small sample size, these findings do not rule out the possibility of a clinically meaningful benefit of brewers' yeast and suggest further research with a larger sample size may be warranted to clarify the potential clinical impact. TRIAL REGISTRATION NUMBER: ACTRN12622000968774.

Intensive Care Units, Neonatal

Re-evaluating pediatric laryngoscope blade size recommendations: Comparable intubation performance across blade sizes in pediatric manikin models.

BACKGROUND: Pediatric airway management traditionally emphasizes strict adherence to age-based laryngoscope blade size recommendations, despite limited empirical validation. OBJECTIVES: To evaluate whether intubation performance varies across a range of blade sizes, and whether a Macintosh 2 blade performs comparably across multiple pediatric age groups in a simulation setting. METHODS: We conducted a randomized crossover simulation study using three pediatric airway manikins (neonate, infant, and child age groups). Emergency medicine residents and faculty physicians performed intubations using multiple laryngoscope blade types and sizes, including standard and nonstandard options. Primary outcomes were intubation time and first-attempt success. Secondary outcomes included complications and operator-rated ease of glottic view and tube passage. Between-blade differences were estimated with 95% confidence intervals. RESULTS: Across manikin sizes and blade types, intubation times were short and first-attempt success rates exceeded 98% in most conditions. Performance remained consistent even with blade sizes outside conventional age-based recommendations. Between-blade differences in intubation time were small, and complication rates were low across conditions. The Macintosh 2 blade performed comparably across all manikin sizes, with similar intubation times, high success rates, and favorable ease ratings. CONCLUSIONS: Intubation performance in pediatric manikin models was similar across a wide range of blade sizes. These hypothesis-generating findings warrant prospective clinical evaluation of simplified blade selection strategies for pediatric intubation.

Manikins

GIP contributes to postprandial regulation of splanchnic blood supply in humans with type 2 diabetes: a randomised, single-blinded, placebo-controlled, crossover study.

AIMS/HYPOTHESIS: In healthy lean humans, endogenous glucose-dependent insulinotropic polypeptide (GIP) contributes significantly to the postprandial increase in arteria mesenterica superior blood flow. The vascular biology related to activation of the GIP receptor is markedly impaired in individuals with type 2 diabetes and is sometimes absent. In this population, we investigated the role of endogenous GIP on postprandial splanchnic blood flow by using the GIP receptor antagonist, GIP(3-30)NH2. The primary outcome of this study was the changes in blood flow in arteria mesenterica superior during oral glucose with or without GIP receptor antagonist infusion. METHODS: Ten participants with type 2 diabetes (age 20-80 years, BMI 20-35 kg/m2, and HbA1c >48 mmol/mol and <75 mmol/mol) were investigated in a randomised, placebo-controlled, crossover study. On four separate occasions, participants received the following treatment: oral glucose + i.v. GIP(3-30)NH2; oral glucose + i.v. saline (154 mmol/l NaCl); oral water + i.v. GIP(3-30)NH2; oral water + i.v. saline. Participants were randomly assigned to intervention groups using (random.org). Participants were unaware of allocation, while investigators were aware. No additional allocation concealment procedures were used. During all four interventions, splanchnic blood flow was measured using phase-contrast MRI in the arteria mesenterica superior, truncus coeliacus and vena portae during oral glucose (75 g) or water ingestion. The study was conducted at Rigshospitalet, Copenhagen. Liver volume and oxygenation, as well as gallbladder volume, were assessed. Blood samples were collected and analysed for insulin, C-peptide, GIP, glucagon and glucose. RESULTS: Oral glucose alone increased mean blood flow in arteria mesenterica superior by 57% (95% CI 26, 88) and this was 15% (95% CI -2, 32) lower during concomitant GIP receptor antagonist infusion, p=0.012. Infusion of GIP receptor antagonist during oral glucose treatment did also result in lower insulin secretion, C-peptide and C-peptide/glucose ratio compared with saline infusion, whereas glucagon levels and plasma glucose were unaffected. Oral water did not affect any outcomes. CONCLUSIONS/INTERPRETATION: Endogenous GIP contributes to postprandially increased splanchnic blood flow in people with type 2 diabetes. TRIAL REGISTRATION: ClinicalTrials.gov NCT06426823 FUNDING: This work was supported by the Novo Nordisk Foundation.

Humans

Physical reconfiguration of limb electrodes for Precordial Bipolar Lead acquisition: Morphological validation against digital subtraction.

BACKGROUND: The V2&#xa0;-&#xa0;V1 Precordial Bipolar Lead (PBL) selectively evaluates the right-to-left retrosternal axis and has shown diagnostic value beyond the standard 12&#x2011;lead electrocardiogram. However, its use has been limited by the need for raw electrocardiographic data and post-processing software. This study evaluated whether a simple physical reconfiguration of limb electrodes could reproduce the digitally derived V2&#xa0;-&#xa0;V1 morphology with sufficient accuracy for clinical application. METHODS: Thirty-seven subjects underwent two sequential 10-s 12&#x2011;lead recordings using a Cardiovit FT-1 electrocardiograph sampled at 1000&#xa0;Hz. In the standard recording, the digital PBL was calculated as V2&#xa0;-&#xa0;V1. In the second recording, the right-arm and left-arm electrodes were repositioned to the V1 and V2 sites so that Lead I directly recorded the retrosternal dipole. Signals were filtered, synchronized, and analyzed using median beats. Morphological agreement was assessed with Pearson correlation on Z-normalized signals, while absolute agreement was evaluated using Lin's concordance correlation coefficient (CCC), intraclass correlation coefficient (ICC (Lewis, 1931; Nehb, 1938 [1,2])), root mean square error (RMSE), and Bland-Altman analysis. RESULTS: Mean Pearson correlation between digital and physical PBL was 0.955 (SD 0.043), with segment-specific correlations of 0.953 (SD 0.054) for QRS and 0.967 (SD 0.052) for ST-T. Lin's CCC and ICC(2,1) were both 0.871 (SD 0.110), and RMSE was 0.091 (SD 0.049) mV. Bland-Altman analysis showed minimal bias (-0.008&#xa0;mV). CONCLUSIONS: Physical acquisition of the V2&#xa0;-&#xa0;V1 PBL achieved high agreement with the digitally derived signal, supporting a simplified analog method for broader clinical implementation.

Humans

Comparison of Traditional Chinese Exercise and Equipment-Based Exercise on Glycaemic Control and Vitamin D Levels in Middle-Aged and Elderly Patients With Prediabetes: A Randomised Controlled Trial.

BACKGROUND: Prediabetes is a critical window for preventing progression to type 2 diabetes mellitus (T2DM). Both vitamin D deficiency and physical inactivity are associated with impaired glucose metabolism. This study compared the effects of Traditional Chinese Exercise (TCE) and Kuanle Equipment Exercise (KEE) on glycaemic measures, lipid profiles, body composition and serum 25-hydroxyvitamin D3 [25(OH)D3] in middle-aged and elderly adults with prediabetes. METHODS: We conducted a 12-week, single-centre, randomised controlled trial involving 62 participants with prediabetes (mean age 55.2&#x2009;&#xb1;&#x2009;8.4&#x2009;years; 88.7% female). Participants were randomly assigned to control (usual care, n&#x2009;=&#x2009;21), TCE (n&#x2009;=&#x2009;20), or KEE (n&#x2009;=&#x2009;21). Primary outcomes included fasting plasma glucose (FPG), 2-h OGTT glucose, glycated haemoglobin (HbA1c) and serum 25(OH)D3. Secondary outcomes comprised triglycerides, total cholesterol, LDL-C, HDL-C and body composition. RESULTS: At baseline, mean serum 25(OH)D3 was 21.53&#x2009;&#xb1;&#x2009;3.90&#x2009;nmol/L. At 12&#x2009;weeks, both TCE and KEE improved FPG, 2-h OGTT glucose, HbA1c and 25(OH)D3 versus control (all p&#x2009;&#x2264;&#x2009;0.001). Relative changes in FPG were -9.4% (TCE) and -15.2% (KEE) versus -1.5% (control); corresponding changes were -14.6% and -21.2% for 2-h OGTT glucose, -6.7% and -12.9% for HbA1c, and +60.6% and +81.9% for 25(OH)D3. Direct TCE-KEE comparisons were not significant (all p&#x2009;>&#x2009;0.05). In an exploratory analysis, change in 25(OH)D3 was inversely associated with change in 2-h OGTT glucose (partial r&#x2009;=&#x2009;-0.358, p&#x2009;=&#x2009;0.006), but not with FPG, HbA1c, or triglycerides. CONCLUSIONS: Both TCE and KEE improved glycaemic outcomes and increased serum 25(OH)D3 compared with usual care in middle-aged and elderly adults with prediabetes. Although KEE produced numerically larger estimates, direct between-group comparisons were not significant, and the superiority of KEE over TCE was not established. These vitamin D findings require confirmation in trials that quantify sunlight exposure and dietary vitamin D intake.

Aged

Comfort and Usability of Digital Versus Conventional Custom-Fit Mouthguards: A Randomized Clinical Trial.

BACKGROUND/OBJECTIVES: The use of mouthguards protects teeth and the supporting tissues against impacts. Digital impressions and 3D-printed models can reduce manufacturing steps and minimize discomfort. This study evaluated the fit, comfort, and usability of custom-made mouthguards, obtained by conventional and digital workflow, in amateur athletes. MATERIALS AND METHODS: Amateur athletes were recruited for this randomized, double-blind, crossover clinical study. Each participant received two 4-mm-thick custom-fit mouthguards made of ethylene vinyl acetate (EVA) sheets using two protocols: conventional impression using alginate to produce dental stone cast (CMP) and intraoral digital scanning to produce 3D-printed resin models (DMP). Each mouthguard was worn during all training and matches over 3&#x2009;months. The order of mouthguard use was randomly assigned. Patient satisfaction with the impression protocol and mouthguard use, model accuracy, and mouthguard fit were assessed. RESULTS: Overall, 46 participants completed the study. The DMP protocol required less execution time (p&#x2009;=&#x2009;0.023), caused less discomfort (p&#x2009;=&#x2009;0.018), anxiety (p&#x2009;=&#x2009;0.008), nausea (p&#x2009;=&#x2009;0.027), difficulty breathing (p&#x2009;<&#x2009;0.001), and unpleasant taste (p&#x2009;=&#x2009;0.006) compared to the CMP protocol. The pain (p&#x2009;=&#x2009;0.971) perceived by the participants was similar in both impression protocols. The CMP-mouthguards were considered to be better fitting by the majority of participants (p&#x2009;=&#x2009;0.027). Between-group comparisons revealed that DMP-mouthguard caused less discomfort immediately postadaptation (p&#x2009;=&#x2009;0.034), with no significant differences observed at 30 or 90&#x2009;days. CONCLUSIONS: The digital workflow demonstrated to be efficient in the fabrication of mouthguards. Digital impression was more comfortable, requiring less execution time, with more accurate printed models and produced mouthguards with reported comfort and fit levels similar to those manufactured conventionally.

Humans

Beyond da Vinci: a systematic review of next-generation multiport robotic platforms in pediatric surgery.

As robotic surgery expands beyond the da Vinci platform, the relevance of new-generation systems to pediatric patients remains uncertain. This review examined the technical characteristics, applications, and perioperative outcomes of alternative multiport robotic platforms in children. PubMed/MEDLINE, Web of Science, Scopus, and the Cochrane Library were searched through 28 February 2026 in accordance with PRISMA 2020. Owing to clinical heterogeneity, findings were synthesized narratively, with Wilson 95% confidence intervals for key binary outcomes. Six studies reported 166 patients across 27 procedure types. Senhance accounted for 164 patients, while Hugo RAS and Hinotori were each represented by one patient. Ages ranged from 15&#xa0;days to 17&#xa0;years and weights from 3.8 to more than 100&#xa0;kg. Senhance was the only platform used with 3-mm robotic instruments. Conversion or planned escalation occurred in 19 patients (11.4%; 95% CI, 7.5-17.2%). Four intraoperative complications were reported (2.4%; 95% CI, 0.9-6.0%). Across all reports, 20 patients experienced postoperative complications (12.0%; 95% CI, 7.9-17.9%). In the largest cohort, seven patients required reintervention (4.6%; 95% CI, 2.2-9.2%) and seven were readmitted (4.6%; 95% CI, 2.2-9.2%). No deaths or comparative pediatric studies were reported. Published experience remains sparse and is almost entirely limited to Senhance. Current evidence describes early clinical use without establishing comparative safety, effectiveness, or platform superiority. Prospective multicenter studies with standardized reporting are needed.

Humans

Analyzing the impact of subcutaneous injection needle, device, and administration characteristics on patient pain, anxiety, and safety: a systematic literature review.

The subcutaneous (SC) injection route is a commonly used and important method for therapeutic delivery of a wide range of compounds, and needle characteristics have a significant influence on patient pain, anxiety, safety, and other outcomes. This systematic review evaluates the evidence on how needle-specific characteristics (e.g. gauge, length, tip design, wall thickness, concealment) and administration- or device-related factors can affect patient-reported outcomes and clinical safety indicators during and following SC injections. A comprehensive search was conducted in MEDLINE, PubMed, Embase, and ClinicalTrials.gov in June 2024. Studies were included if they assessed the relationship between needle characteristics and pain, anxiety, safety, or related outcomes in individuals receiving SC injections. A dual-reviewer process was used for study selection, data extraction, and quality assessment. Sixty-two studies met inclusion criteria. Evidence consistently indicated that thinner and shorter needles reduced patient-reported pain and adverse events such as bruising and bleeding. Tapered and lubricated needles, hidden or retractable needle designs, and use of autoinjectors or prefilled syringes also contributed to reduced anxiety and improved user satisfaction. However, results were heterogeneous, and many studies lacked sufficient power or single-variable evaluation of individual needle parameters, limiting definitive conclusions. Needle characteristics significantly influence patient experience and safety with SC delivery. While both clinical evidence and practical experience clearly favor thinner, shorter, and concealed needles, further standardized, high-quality research is needed to isolate and quantify the specific contributions of individual needle characteristics to optimize injection practices and support patient-centered device design.

Humans

Shielding performance and clinical applicability of lead-free materials in computed tomography.

Owing to the high radiation exposure associated with computed tomography (CT) examinations and the image quality degradation caused by conventional radiation shielding materials, this study evaluated the dose reduction performance and image quality maintenance potential of a newly developed lead-free composite shielding material. This material was composed of bismuth, tungsten, tungsten carbide, aluminium, and polyurethane. Phantom-based dose measurements demonstrated that the shielding material achieved dose reduction rates ranging from 17.6% to 37.6%, depending on tube voltage. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and changes in tube current-time product (mAs) under a scout-based automatic exposure control (AEC) protocol were analysed according to the presence or absence of the shielding material across regions. For the clinical evaluation, CT scans were performed on four patients. Furthermore, the images were reviewed to evaluate whether this material affected image quality. The shielding material exhibited radiation reduction levels comparable to those reported in previous studies. SNR and CNR analyses showed minor statistical variations in certain regions; however, most differences were not statistically significant, and even significant differences remained within a range that did not compromise diagnostic image quality. Under the scout-based AEC protocol, the use of the shielding material resulted in less than 1% variation in mAs values. No visually perceptible artefacts or clinically significant image quality degradation were observed. The proposed composite shielding material demonstrated the potential to mitigate some limitations of conventional shielding materials and showed preliminary clinical feasibility as an adjunctive strategy for radiation dose reduction in CT examinations.

Radiation Protection

Fundamentals of pacemakers ECG interpretation - part 2.

BACKGROUND: Modern pacemakers incorporate arrhythmia-response algorithms, ventricular pacing minimization protocols, and safety mechanisms that generate ECG patterns indistinguishable from pathological AV block, sensing malfunction, or device-mediated tachycardia. Failure to recognize these algorithm-driven signatures leads to unnecessary interventions, misdiagnosis, and inappropriate device reprogramming. This manuscript is the second in a two-part series on pacemaker ECG interpretation. METHODS: We conducted a narrative review of peer-reviewed literature and device-specific documentation on algorithm-driven ECG behavior, synthesizing evidence across arrhythmia recognition, upper rate physiology, ventricular pacing minimization, mode switching, safety mechanisms, and hysteresis algorithms. RESULTS: Pacemaker-mediated tachycardia produces regular paced wide-complex tachycardia locked at the upper tracking rate, initiated by any event with retrograde VA conduction. Ventricular tachycardia is identified by QRS morphology diverging from the known paced pattern, absent pacing spikes, and AV dissociation. Upper rate Wenckebach behavior mimics Mobitz type I AV block; 2:1 upper rate response mimics second-degree AV block. Ventricular pacing minimization algorithms produce isolated nonconducted P waves and prolonged AV intervals that simulate pathological conduction disease. Mode switching causes abrupt rate drops misidentified as output failure. Ventricular safety pacing generates a conspicuously short, fixed AV interval. Three discrete pacing artifacts reflect AV-sequential cardiac resynchronization therapy (CRT), ventricular safety pacing in CRT, or His-bundle pacing with backup RV output. Rate and AV hysteresis produce pauses and wandering AV intervals mimicking oversensing or Wenckebach periodicity. CONCLUSIONS: Recognizing algorithm-driven ECG patterns requires knowledge of device timing intervals and refractory periods, which lets clinicians distinguish programmed behavior from true malfunction or cardiac arrhythmia.

Humans

The environmental impact of diagnosis and therapy in obstructive sleep Apnea: A systematic review.

Healthcare contributes significantly to global greenhouse gas (GHG) emissions, yet the environmental impact of sleep medicine, particularly the diagnosis and therapy of obstructive sleep apnea (OSA), remains poorly characterized. We systematically searched PubMed, Scopus, and Embase (2015-2025) for studies on OSA care reporting environmental metrics (carbon footprint, energy use, resource consumption) or healthcare resource utilization. Supplementary searches identified additional non-peer-reviewed sustainability-focused studies that have been presented at conferences. Of 19 primary peer-reviewed studies on OSA care and utilization, only one reported environmental metrics (telemedicine CO2 savings related to reduction in travel-related emissions). Supplementary sources revealed that OSA care has a measurable carbon footprint driven by disposable equipment, device electricity, and travel and that OSA diagnostics create significant solid waste with opportunities for waste reduction through the use of reusable equipment. This review shows that while the environmental impact of sleep medicine has been rarely studied to this date, available evidence suggests significant opportunities for sustainability through virtual care, home testing, and equipment optimization. Future research should incorporate environmental impact into the assessment of clinical pathways.

Humans

An automated geometric modeling framework in GATE for the design and optimization of high-sensitivity converging-beam SPECT collimators.

Objective.The trade-off between detection sensitivity and spatial resolution is a fundamental challenge in designing organ-dedicated Single-photon emission computed tomography (SPECT) collimators. While converging-hole geometries offer a solution, their optimization is often hindered by the lack of flexible computational tools capable of modeling large-scale, non-parallel hole arrays. This study aims to develop an automated geometric modeling framework to facilitate the design and evaluation of complex converging- and diverging-hole collimators within standard Monte Carlo environments.Approach.We developed a specialized modeling framework by implementing custom C++ classes and a vector-based alignment algorithm within GATE. This platform enables automated, orientation-consistent construction of large-scale converging arrays not natively supported by standard implementations. A high-sensitivity pure cone-beam collimator (CBC) was designed using this framework. The evaluation used hot-rod, disc, and Jaszczak phantoms for physical characterization, while XCAT and dedicated brain models were employed for clinical tasks, including cardiac, brain perfusion, and DaTscan SPECT simulations.Main results.The CBC achieved a nearly fourfold sensitivity increase compared to a conventional low-energy high-resolution parallel-hole collimator at a 20 cm radius of rotation, while maintaining comparable spatial resolution. Despite a 52.3% field of view reduction, the CBC yielded a 2.2-fold noise reduction (CV: 11.7% vs 25.9%) and mitigated partial volume effects via geometric magnification. XCAT and brain phantom simulations confirmed enhanced anatomical definition and contrast recovery in cardiac, perfusion, and DaTscan tasks.Significance.This work provides an efficient computational tool for rapid design space exploration of advanced collimator geometries. The results demonstrate that the proposed CBC design offers a significant sensitivity advantage, making it highly suitable for high-performance, small-volume clinical applications such as brain and cardiac molecular imaging.

Tomography, Emission-Computed, Single-Photon

Regional genomic analysis of lineage distribution and transferable multidrug resistance among chicken-associated Salmonella Kentucky isolates in China.

Salmonella enterica serovar Kentucky is an important multidrug-resistant foodborne pathogen in the poultry meat supply chain. Although recent broader genomic studies have elucidated the population structure and epidemiological significance of major lineages in China (e.g., ST198 and ST314), the regional dynamics within local poultry supply chains remain insufficiently characterized. In this study, 31 chicken meat-derived isolates from Shanghai and 39 publicly available genomes from China were analyzed using antimicrobial susceptibility testing, whole-genome sequencing, phylogenetic analysis, conjugation experiments, and complete sequencing of representative plasmids. This enabled a systematic characterization of the molecular epidemiological features of the population and the mechanisms underlying resistance dissemination. Population genomic analysis revealed a lineage composition markedly different from the global epidemiological pattern: ST314 was the predominant sequence type among the Shanghai chicken-derived isolates (74.2%), whereas the internationally recognized high-risk clone ST198 accounted for only 25.8% of the local isolates. However, risk stratification analysis indicated that although ST198 was detected less frequently, it carried a significantly greater burden of acquired resistance genes and therefore represented a higher-risk resistant lineage. Functional and structural validation further elucidated the molecular basis of resistance dissemination within this high-risk lineage. Conjugation experiments confirmed the co-transfer of a multidrug resistance module carrying blaTEM-1 and blaCTX-M-267 to the recipient strain Escherichia coli J53. Complete plasmid analysis revealed that these two &#x3b2;-lactam resistance genes were co-localized on a 242-kb transferable plasmid flanked by Tn1331, Tn3, and multiple transposase-associated elements, thereby providing a structural basis for their horizontal transfer. This study provides important molecular epidemiological evidence for lineage-specific surveillance and risk-stratified control of resistant Salmonella in the poultry meat supply chain and further underscores the need for continuous monitoring of mobile genetic elements within a One Health framework.

Animals

Endoscopic Ultrasound-Guided Franseen Fine-Needle Biopsy for Solid Pancreatic Lesions: A Systematic Review and Meta-Analysis.

INTRODUCTION: Accurate tissue acquisition (TA) of solid pancreatic lesions is essential for guiding treatment with endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) being the preferred method. Among FNB designs, the three-pronged Franseen-tip needle demonstrates strong diagnostic performance, though direct head-to-head comparisons with other FNB designs remain limited. METHODOLOGY: This meta-analysis was conducted in accordance with PRISMA guidelines (PROSPERO: CRD420251123856). Eligible studies enrolled patients with solid pancreatic lesions who underwent EUS-guided FNB, directly compared the Franseen-tip with other FNB needles. Six databases were systematically searched through July 2025, and study selection, data extraction, and risk of bias assessment (QUADAS-2 tool) were performed independently by two reviewers. Pooled estimates were generated using random-effects and bivariate hierarchical models. RESULTS: Sixteen studies (2,010 Franseen vs. 2,811 comparator) were included. Bivariate analysis showed that sensitivity and specificity of the Franseen needle were comparable to newer-generation comparator needles (sensitivity 91.3% vs. 94.0%; specificity 99.99% vs. 99.15%), whereas older-generation needles demonstrated lower sensitivity (80.8%) and inferior discriminatory performance (Negative Likelihood Ratio [LR&#x207b;] 0.19 vs. 0.09). Diagnostic accuracy was higher with the Franseen needle (RR 1.07, 95% CI 1.01-1.14; I2&#x2009;=&#x2009;69%). Sample adequacy was similar overall (RR 1.04, 95% CI 0.95-1.14) but superior to older-generation needles (RR 1.19, 95% CI 1.02-1.41) and in lesions&#x2009;>&#x2009;30&#xa0;mm (RR 1.14, 95% CI 1.02-1.28, I2&#x2009;=&#x2009;81.2%). The Franseen needle achieved nominally strong diagnostic performance (DOR 116.6), although small-study effects were observed. Primary procedural outcomes were comparable between Franseen and comparator needles, including technical success (RR 1.00, 95% CI 0.98-1.02) and histological core procurement (RR 1.04, 95% CI 0.92-1.17). The Franseen needle had fewer low-cellularity samples (RR 0.56, 95% CI 0.45-0.69) and lower specimen bloodiness (RR 0.48, 95% CI 0.25-0.90) but a slightly higher overall adverse event rate (RR 1.29, 95% CI 1.06-1.57). CONCLUSION: The Franseen needle provides superior diagnostic accuracy and sample adequacy compared to older-generation FNB needles with comparable performance to newer-generation designs. It reduces low-cellularity samples and specimen bloodiness, although adverse events are slightly increased, with other primary procedural outcomes remaining comparable. TRIAL REGISTRATION: PROSPERO (Registration No. CRD420251123856).

Humans