Search PubMedSearch

SEARCH · Search PubMed

Results for “platform design”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

645 records · Page 9Linked to original sources

Human-Centered Workspace Optimization: A 2 × 2 Factorial Study of Adjustable Furniture and Indoor Environmental Quality.

Small workspaces function as integrated systems, yet ergonomic furniture and indoor environmental conditions are usually evaluated separately. A six-site, assessor-blinded, randomized 2 × 2 factorial controlled study was conducted of two multicomponent packages-adjustable furniture and optimized indoor environmental quality (IEQ)-among 240 office workers for four weeks. Each group included 60 participants. Overall comfort in week 4 was highest for both packages (5.62 ± 0.53 versus 3.99 ± 0.60 with fixed furniture and basic IEQ). In a site-adjusted factorial model with HC3 robust standard errors, the adjustable-furniture effect was 0.86 points (95% confidence interval [CI], 0.62-1.09), the optimized-IEQ effect was 0.34 points (95% CI, 0.12-0.55), and their interaction was 0.44 points (95% CI, 0.14-0.74). Adjustable furniture improved postural comfort and reduced neck and lower back discomfort; optimized IEQ improved environmental comfort; both packages improved perceived productivity, satisfaction, and fatigue. The task-accuracy interaction did not remain significant after false-discovery-rate adjustment, and exploratory mediation and spline analyses did not support indirect or nonlinear effects. These results support coordinated ergonomic and environmental implementation while preserving distinct outcome pathways.

Interior Design and Furnishings

Clinical performance of two lithium disilicate CAD/CAM materials in posterior Class II inlay restorations: A 48-month randomised split-mouth clinical trial.

OBJECTIVES: To compare the clinical performance of Amber Mill (AM) and IPS e.max CAD (EM) lithium disilicate computer-aided design/computer-aided manufacturing (CAD/CAM) materials in posterior Class II inlay restorations and characterise their baseline properties. METHODS: Thirty-four adults received paired AM and EM posterior Class II inlays (68 restorations) in a triple-blind randomised split-mouth trial followed for 48 months. Restorations were evaluated at baseline and annually using revised World Dental Federation (FDI) criteria, with fracture and retention as the primary endpoint. Baseline characterisation included flexural strength, shear bond strength, translucency parameter, and scanning electron microscopy. McNemar, Wilcoxon signed-rank, Friedman, one-way analysis of variance, Tukey post hoc, and inter-rater agreement analyses were used. RESULTS: At 48 months, 18 paired participants were available for primary analysis. Failures occurred in 2 of 18 AM restorations and in 3 of 18 EM restorations, corresponding to success rates of 88.9% and 83.3%, respectively, with no significant between-material difference (McNemar p = 1.000). No catastrophic bulk ceramic fracture was observed. Secondary FDI scores remained mostly within the clinically acceptable range; marginal staining deteriorated over time in both groups (p < .001) without significant between-material differences. Baseline material testing showed significant material- and translucency-dependent differences in flexural strength, shear bond strength, and translucency. CONCLUSIONS: Within the limitations of the 48-month follow-up and the tested Class II inlay indication, AM showed clinical performance comparable to EM. Observed clinical complications were related to retention or marginal/interface behaviour. CLINICAL SIGNIFICANCE: For posterior Class II lithium disilicate CAD/CAM inlays, medium-term complications were mainly retention/interface-related, suggesting adhesive-interface durability may be as important as baseline ceramic strength.

Humans

Remotely Supervised, Home-Based Transcranial Direct Current Stimulation for Major Depressive Disorder: Systematic Review and Meta-Analysis.

BACKGROUND: Major depressive disorder affects over 280 million people worldwide, and access to effective treatment remains limited. Transcranial direct current stimulation (tDCS) is a noninvasive option, and portable devices now allow for home-based delivery under varying degrees of remote supervision. OBJECTIVE: This study aimed to systematically review and meta-analyze the efficacy, safety, feasibility, and acceptability of home-based and remotely supervised tDCS for depressive disorders. METHODS: Following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) 2020 and PRISMA-S (Preferred Reporting Items for Systematic Reviews and Meta-Analyses literature search extension) guidelines, we searched MEDLINE, Embase, Web of Science, the Cochrane databases, ClinicalTrials.gov, and the World Health Organization International Clinical Trials Registry Platform up to July 2025, with backward and forward citation searching. Two reviewers independently screened records, extracted data, and assessed risk of bias (version 2 of the Cochrane risk-of-bias tool for randomized trials, Newcastle-Ottawa Scale for observational studies, and Critical Appraisal Skills Programme for qualitative studies) and certainty of evidence (Grading of Recommendations Assessment, Development, and Evaluation; GRADE). RESULTS: This review included 12 distinct studies (16 reports), of which 6 (50%) were randomized sham-controlled trials forming the meta-analytic pool. Active home-based tDCS produced a small, statistically significant improvement over sham (pooled Hedges g=0.36, 95% CI 0.06-0.66; P=.03; I2=34.3%). The effect was not robust to removal of the single largest positive trial (omitting the one study from 2025: g=0.39, 95% CI -0.12 to 0.91), and trial-level results were mixed: the 2 largest trials (one unsupervised [n=210] and one self-administered [n=141]) were negative on their primary depression outcomes, whereas the largest real-time supervised trial (n=174) was positive (between-group 95% CI 0.51-4.01; P=.01). This estimate was concordant in direction with an independent peer-reviewed meta-analysis of overlapping trials, which reported a pooled Montgomery-&#xc5;sberg Depression Rating Scale reduction (weighted mean difference -2.74, 95% CI -4.19 to -1.29) and Hamilton Depression Rating Scale reduction (weighted mean difference -2.24, 95% CI -4.16 to -1.49), attenuating to nonsignificance (P>.05) in major depressive disorder without comorbid cognitive impairment. The pooled effect fell at or near the minimal clinically important difference. GRADE certainty was moderate. Adverse events were predominantly mild: one pilot study was terminated early for skin lesions, and one nonfatal suicide attempt occurred in an unsupervised trial. CONCLUSIONS: Home-based and remotely supervised tDCS produces a small, statistically significant but clinically modest antidepressant effect that is sensitive to the inclusion of the largest positive trial, with the 2 largest trials being negative. The available controlled evidence does not establish supervision intensity as a determinant of efficacy. Current data are insufficient to recommend routine clinical adoption; adequately powered trials with standardized supervision and longer follow-up are needed.

Humans

Sugar rationing during the first 1000 days and early onset cancer: a natural experiment.

BACKGROUND: The "first 1000 days" of life is a critical window for metabolic programming, while the long-term oncological consequences of nutritional exposures during this period remain understudied. OBJECTIVES: We aimed to evaluate whether restricted sugar intake in utero and during early childhood reduces risk of early onset cancer diagnosis and mortality in adulthood, utilizing a natural experiment. METHODS: We analyzed 63,819 United Kingdom Biobank participants born between October 1951 and March 1956, spanning the end of United Kingdom sugar rationing (September 1953). Leveraging a quasi-experimental birth cohort design, we compared participants exposed to sugar rationing in utero and during infancy with those unexposed. Early onset cancer incidence (&#x2264;50 y) and mortality were ascertained via integrated national Cancer Registry and hospital inpatient records. Multivariable Cox proportional hazards models (including Gompertz distribution) were used to estimate hazard ratios (HRs), with exploratory site-specific analyses. RESULTS: Among 63,819 participants (56.3% female), 40,397 were exposed to rationing and 23,422 were unexposed. Early life sugar restriction significantly reduced early onset cancer risk (HR: 0.66; 95% confidence interval: 0.53, 0.81; P < 0.001). A dose-response relationship was observed, with peak protection in individuals exposed for &#x2264;24 mo postnatally. This protection was observed systemically across solid tumors, independent of specific cancer sites. Specificity was corroborated by null associations with negative controls (herpes zoster and cataract). No significant difference was found for cancer-specific mortality. CONCLUSIONS: Restricting sugar intake during the first 1000 days is associated with a reduced risk of early onset cancer, extending the disease-free lifespan. The divergence between reduced incidence and unchanged mortality suggests early life metabolic environments primarily influence tumor latency rather than biological aggressiveness. These findings highlight the potential long-term public health implications of early life dietary guidelines against the rising burden of early onset cancer.

Humans

Re-evaluating pediatric laryngoscope blade size recommendations: Comparable intubation performance across blade sizes in pediatric manikin models.

BACKGROUND: Pediatric airway management traditionally emphasizes strict adherence to age-based laryngoscope blade size recommendations, despite limited empirical validation. OBJECTIVES: To evaluate whether intubation performance varies across a range of blade sizes, and whether a Macintosh 2 blade performs comparably across multiple pediatric age groups in a simulation setting. METHODS: We conducted a randomized crossover simulation study using three pediatric airway manikins (neonate, infant, and child age groups). Emergency medicine residents and faculty physicians performed intubations using multiple laryngoscope blade types and sizes, including standard and nonstandard options. Primary outcomes were intubation time and first-attempt success. Secondary outcomes included complications and operator-rated ease of glottic view and tube passage. Between-blade differences were estimated with 95% confidence intervals. RESULTS: Across manikin sizes and blade types, intubation times were short and first-attempt success rates exceeded 98% in most conditions. Performance remained consistent even with blade sizes outside conventional age-based recommendations. Between-blade differences in intubation time were small, and complication rates were low across conditions. The Macintosh 2 blade performed comparably across all manikin sizes, with similar intubation times, high success rates, and favorable ease ratings. CONCLUSIONS: Intubation performance in pediatric manikin models was similar across a wide range of blade sizes. These hypothesis-generating findings warrant prospective clinical evaluation of simplified blade selection strategies for pediatric intubation.

Manikins

Clinical performance of monolithic and veneered zirconia three-unit posterior FDPs: A five-year multicenter randomized controlled trial.

AIM: This randomized controlled clinical study compared monolithic, partially veneered, and fully veneered zirconia FDPs over a 5-year period with respect to survival, technical and biological complications, and patient-reported outcome measures (PROMs). MATERIALS AND METHODS: Sixty-four patients requiring three-unit posterior FDPs were randomly allocated to monolithic (MONO-FDP), partially veneered (PV-FDP), or fully veneered (FV-FDP) groups. All FDPs were fabricated from 4 mol% Y&#x2082;O&#x2083; partially stabilized zirconia (4Y-TZP). Follow-up examinations were conducted at baseline, 1, 3, and 5 years. Technical parameters were evaluated using modified USPHS criteria. Periodontal measurements (PPD, BOP, PI) and patient satisfaction were assessed at all time points. RESULTS: A total of 63 FDPs were evaluated at baseline, 57 at 3 years, and 54 at 5 years. Survival at 5 years was 94.7% for MONO-FDPs, 100% for FV-FDPs and 100% for PV-FDPs. Technical complications occurred exclusively in PV-FDP (33%) and FV-FDP (38%) groups and consisted of minor, polishable chipping; no chipping or fractures were recorded in MONO-FDPs (0%) with statistically significant difference between MONO-FDP and the other two groups (p &#x2264; 0.014). Biological parameters remained stable across all groups, with no significant differences in PPD, BOP, or PI. PV-FDPs and FV-FDPs tended to receive more favorable professional color ratings, whereas PROMs were similar among the groups. CONCLUSIONS: All three FDP designs-monolithic, partially veneered, and fully veneered-fabricated from 4Y-TZP zirconia demonstrated excellent 5-year clinical performance. Technical complications were limited to PV- and FV-FDPs and consisted of minor chipping. Biological outcomes and patient satisfaction were similar across groups. CLINICAL SIGNIFICANCE: The five-year outcomes suggest that veneered, partially veneered, and monolithic FDPs can be used with high clinical reliability; however, restorations incorporating veneering ceramic may present an elevated risk of ceramic chipping.

Humans

Evaluating Patient Satisfaction and Oral Health Impact Profile-14 (OHIP-14): A Multicenter Crossover Study Comparing Selective Pressure Impression Conventional Dentures with Mucostatic Digital Dentures.

PURPOSE: To compare patient satisfaction and oral health impact between individuals receiving complete dentures made by digital methods and those using conventional techniques. MATERIALS AND METHODS: In this randomized crossover clinical trial, 23 patients aged 40 years and older with completely edentulous arches were enrolled at three treatment centers. Each participant received two sets of complete dentures: one set created using conventional methods (selective pressure impression) and the other through digital techniques (mucostatic digital impression). The order of denture placement was randomized, with each set used for 4 weeks. A trained specialist administered treatments alongside research tools, including a general information questionnaire, a denture satisfaction survey, and the OHIP-14 interview tool. Statistical analysis was conducted using Mann-Whitney U test. RESULTS: Participants with digital dentures reported significantly higher satisfaction regarding treatment duration, comfort, confidence, chewing ability, esthetics, and overall satisfaction compared to those with conventional dentures. There were no significant differences in satisfaction concerning speech and pronunciation. Overall, the oral health impact on quality of life was similar between denture types, but participants indicated improved quality of life while using dentures compared to being edentulous. CONCLUSIONS: Patients with digital dentures exhibited greater satisfaction across various domains compared to those with conventional dentures, despite similar satisfaction levels in speech and pronunciation. The impact on quality of life was comparable between both types, as measured by the OHIP-14.

Humans

Application of Three-Dimensionally Printed Surgical Guides in Precise Sacral Tumor Excision and Defect Reconstruction.

OBJECTIVE: Precise resection of sacral tumors remains technically demanding due to their deep anatomical location and close proximity to critical neurovascular structures. Conventional freehand techniques often result in suboptimal resection margins, excessive blood loss, and compromised lumbopelvic stability. This study evaluated whether patient-specific three-dimensional (3D)-printed guiding templates improve surgical accuracy and perioperative outcomes in sacral tumor resection and reconstruction. METHODS: Nineteen patients undergoing en bloc sacral tumor resection (S1-S3 involvement) with spinopelvic reconstruction (2006-2020) were retrospectively analyzed. Patients were divided into a 3D-printing group (n&#x2009;=&#x2009;10) and a conventional freehand group (n&#x2009;=&#x2009;9). In the 3D-printing group, computer-aided design and 3D-printed templates were used for osteotomy, screw placement, and defect reconstruction. Perioperative metrics, surgical accuracy, and complications were compared between groups using Welch's t-test and the Hodges-Lehmann method; oncologic events during follow-up were recorded descriptively. RESULTS: The 3D-printing group demonstrated significantly shorter operative time (456.5&#x2009;&#xb1;&#x2009;62.36 vs. 574.44&#x2009;&#xb1;&#x2009;114.58&#x2009;min, p&#x2009;=&#x2009;0.012), reduced blood loss (4081.40&#x2009;&#xb1;&#x2009;838.99 vs. 5090.0&#x2009;&#xb1;&#x2009;1059.67&#x2009;mL, p&#x2009;=&#x2009;0.034), and fewer fluoroscopic exposures (4.2&#x2009;&#xb1;&#x2009;0.79 vs. 10.0&#x2009;&#xb1;&#x2009;1.58, p&#x2009;<&#x2009;0.001) compared with the conventional group. Osteotomy accuracy was also superior in the 3D-printing group, with significantly lower angular deviation (3.33&#xb0;&#x2009;&#xb1;&#x2009;0.45&#xb0; vs. 6.79&#xb0;&#x2009;&#xb1;&#x2009;2.16&#xb0;, p&#x2009;=&#x2009;0.0012). Postoperative complication rates were comparable (30% vs. 44.4%, p&#x2009;=&#x2009;0.649), but hospital stay was significantly shorter in the 3D-printing group (10.7&#x2009;&#xb1;&#x2009;2.71 vs. 18.11&#x2009;&#xb1;&#x2009;4.01&#x2009;days, p&#x2009;<&#x2009;0.001). CONCLUSION: Patient-specific 3D-printed guiding templates enhance precision in sacral tumor excision and reconstruction, improving surgical efficiency and perioperative safety. This computer-assisted, template-guided approach represents a valuable advancement for complex sacral oncologic surgery.

Humans

Shielding performance and clinical applicability of lead-free materials in computed tomography.

Owing to the high radiation exposure associated with computed tomography (CT) examinations and the image quality degradation caused by conventional radiation shielding materials, this study evaluated the dose reduction performance and image quality maintenance potential of a newly developed lead-free composite shielding material. This material was composed of bismuth, tungsten, tungsten carbide, aluminium, and polyurethane. Phantom-based dose measurements demonstrated that the shielding material achieved dose reduction rates ranging from 17.6% to 37.6%, depending on tube voltage. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and changes in tube current-time product (mAs) under a scout-based automatic exposure control (AEC) protocol were analysed according to the presence or absence of the shielding material across regions. For the clinical evaluation, CT scans were performed on four patients. Furthermore, the images were reviewed to evaluate whether this material affected image quality. The shielding material exhibited radiation reduction levels comparable to those reported in previous studies. SNR and CNR analyses showed minor statistical variations in certain regions; however, most differences were not statistically significant, and even significant differences remained within a range that did not compromise diagnostic image quality. Under the scout-based AEC protocol, the use of the shielding material resulted in less than 1% variation in mAs values. No visually perceptible artefacts or clinically significant image quality degradation were observed. The proposed composite shielding material demonstrated the potential to mitigate some limitations of conventional shielding materials and showed preliminary clinical feasibility as an adjunctive strategy for radiation dose reduction in CT examinations.

Radiation Protection

Astigmatic vector outcomes after FS-LASIK versus SMILE for high myopic astigmatism: a single-center retrospective comparative cohort study without cyclotorsion compensation.

PURPOSE: To compare astigmatic correction vector outcomes between femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and small-incision lenticule extraction (SMILE, also termed Keratorefractive Lenticule Extraction, KLEx) without intraoperative cyclotorsion compensation in patients with high myopic astigmatism (-&#x2009;2.00 to&#x2009;-&#x2009;3.75 D), and to clarify procedure-specific correction tendencies under this non-standardized alignment protocol. METHODS: This single-center retrospective comparative cohort study enrolled 155 eyes (one eye randomly selected per patient) that underwent FS-LASIK (80 eyes) or SMILE/KLEx (75 eyes) for high myopic astigmatism correction from January 2023 to July 2024 in Beijing Fenglian Jiayue Lige Clinic. Intraoperative cyclotorsion compensation was intentionally disabled to isolate inherent procedural astigmatism correction characteristics. Standardized Alpins vectorial analysis was performed at 3&#xa0;months and 12&#xa0;months postoperatively. PRIMARY ENDPOINT: 12-month Alpins correction index (CI). Multivariable propensity score adjustment was applied to mitigate confounding by clinical treatment selection bias. Statistical multiplicity control was implemented for secondary vector and visual outcomes. RESULTS: Baseline demographic, refractive, corneal and ocular biometric parameters were balanced between groups after propensity matching. No statistically significant intergroup differences were detected in uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), residual cylinder, safety index or efficacy index at 3 and 12&#xa0;months (all P&#x2009;>&#x2009;0.05). Under the non-cyclotorsion-compensated protocol, significant intergroup differences were identified in the magnitude of surgically induced astigmatism (SIA), correction index (CI), and magnitude error (ME) at both follow-up timepoints (all P&#x2009;<&#x2009;0.0001). Target induced astigmatism (TIA), difference vector (DV), index of success (IOS), and angle error (AE) magnitudes were comparable between groups (all P&#x2009;>&#x2009;0.05). The vector mean axis of DV differed significantly between groups at 3 and 12&#xa0;months (Watson-Williams circular test, all P&#x2009;<&#x2009;0.0001). No reoperations were documented in clinic medical records for either cohort. No standardized dry eye questionnaires, tear film testing or corneal nerve density metrics were collected to quantify dry eye adverse events; only unstructured clinical notes were reviewed for complication screening. CONCLUSIONS: Under surgical alignment without cyclotorsion compensation, FS-LASIK and SMILE/KLEx both yielded acceptable visual and refractive safety/efficacy for high myopic astigmatism (-&#x2009;2.00 to&#x2009;-&#x2009;3.75 D) at 1-year follow-up, but demonstrated divergent astigmatism correction tendencies: FS-LASIK exhibited relative astigmatism overcorrection (vector mean DV:&#x2009;-&#x2009;0.35&#x2009;&#xb1;&#x2009;0.43 D&#x2009;&#xd7;&#x2009;91&#xb0;, CI&#x2009;>&#x2009;1), while SMILE/KLEx showed relative undercorrection (vector mean DV:&#x2009;-&#x2009;0.21&#x2009;&#xb1;&#x2009;0.53 D&#x2009;&#xd7;&#x2009;12&#xb0;, CI&#x2009;<&#x2009;1). These correction biases are specific to the study's manual limbal alignment protocol without cyclotorsion tracking and cannot be generalized to modern optimized surgical platforms equipped with automated cyclotorsion compensation. Residual refractive errors across both groups are likely multifactorial, including differential corneal stromal healing responses, divergent femtosecond/excimer laser tissue modification mechanisms, and uncorrected intraoperative ocular cyclotorsion.

Humans

Virtual surgical planning-assisted versus free-hand head and neck reconstruction: Systematic review, meta-analysis, and a novel classification.

Virtual surgical planning (VSP)-assisted reconstruction is increasingly used as an alternative to conventional free-hand (FH) techniques in mandibular and maxillary free-flap reconstruction. This systematic review and meta-analysis compared clinical outcomes and proposed a Reconstruction Complexity-Completeness classification. PubMed/MEDLINE, Scopus, Web of Science, Google Scholar, and reference lists were searched from inception to 20 June 2026. Comparative studies were eligible. Risk of bias was assessed using RoB 2 or the Newcastle-Ottawa Scale. Random-effects meta-analyses used restricted maximum likelihood estimation and Hartung-Knapp adjustment. Forty-two studies included 2763 patients (1204 VSP; 1559 FH). VSP significantly reduced operative time (33 studies; MD -64.75&#x202f;min, 95% CI -83.51 to -46.00), ischemia time (15 studies; MD -37.40&#x202f;min, 95% CI -48.97 to -25.82), and hospital stay (16 studies; MD -1.75 days, 95% CI -3.43 to -0.08). VSP was associated with significantly lower odds of bony non-union (OR 0.31, 95% CI 0.16-0.59) and malocclusion (OR 0.14, 95% CI 0.03-0.64), whereas flap loss, surgical site infection, and plate exposure did not differ significantly. VSP-assisted reconstruction was associated with improved operative efficiency, shorter hospitalization, and lower odds of bony non-union and malocclusion, while no statistically significant differences were detected in flap loss, surgical site infection, or plate exposure. The proposed classification may support complexity-adjusted reporting and comparison.

Humans

Efficacy and Safety of Psychedelic Microdosing on Psychological Outcomes in Healthy Adults: A Systematic Review and Meta-analysis.

BACKGROUND: Psychedelic microdosing has gained increasing popularity for enhancing mood and cognition, yet its effects on psychological outcomes in healthy adults remain unclear. We aim to evaluate the efficacy and safety of psychedelic microdosing on psychological outcomes in healthy/non-clinical adult&#xa0;population. METHODS: This review was registered in the International Prospective Register of Systematic Reviews (PROSPERO; CRD420251035294). We searched Embase, MEDLINE, and PsycINFO from inception to February 2026 for original studies in healthy adults using sub-hallucinogenic psychedelic doses on separate days. We included randomized studies, nonrandomized prospective studies, cross-sectional studies, and observational longitudinal designs and stratified meta-analyses by design. Random-effects models were used; safety in randomized controlled trials (RCTs) was pooled as risk differences (RDs). Risk of bias was assessed using the Joanna Briggs Institute (JBI) critical appraisal tools appropriate for each study design. RESULTS: 24 studies (3,681 participants) met inclusion criteria, 6 contributed to meta-analyses. RCTs of psilocybin and LSD microdosing showed subjective and neurophysiological effects but minimal impact on cognition, creativity, or sustained mood. Psilocybin altered EEG and speech with little behavioral change, while LSD caused transient mood and minor physiological effects without lasting cognitive or personality benefits. Observational studies indicated mood and personality improvements, likely influenced by expectancy or lifestyle factors. Meta-analyses included two parallel RCTs (3 comparisons; n = 117) and three non-RCT studies (n = 1,013). Adverse event analyses included two RCTs (4 comparisons; n = 109). RCTs showed no clear evidence of immediate symptom reduction: depressive symptoms (SMD = -0.19; 95% CI -0.56, 0.19; I2 = 0%), anxiety (SMD = -0.20; 95% CI -1.11, 0.71; I2 = 82.3%),and stress (SMD = 0.02; 95% CI -0.39, 0.43; I2 = 0%). Non-RCT within-arm estimates were imprecise and heterogeneous for depressive symptoms (SMCC -0.33; 95% CI -0.75, 0.08) and anxiety (SMCC -0.29; 95% CI-0.84, 0.26). Exploratory pooling across all designs suggested decreases in depressive symptoms and stress, while anxiety remained uncertain. Adverse event risks were similar between treatment and control. CONCLUSIONS: Microdosing does not show consistent immediate benefits for depressive, anxiety, or stress symptoms in healthy adults, and evidence from RCTs remains inconclusive. Although improvements were observed in some studies, these effects were not significantly different from placebo. Larger, well-designed RCTs are needed to clarify the efficacy and safety of psychedelic microdosing beyond placebo.

Humans

A hybrid effectiveness-implementation trial to integrate precision skin cancer risk feedback in federally qualified health centers.

BACKGROUND: Skin cancers are the most common type of cancer in the United States, occur in all segments of the population, and are preventable. Our previous research with primary care patients' demonstrated interest in and efficacy of a precision prevention intervention providing feedback on MC1R risk level (higher versus average) in combination with prevention education materials relative to a standard educational intervention. Our current study is a hybrid type 1 effectiveness-implementation trial deployed at six federally-qualified health centers. This paper presents the study protocol. METHODS: A community advisory panel will guide development of study materials and measures. Staff training at each clinic will be completed in-person. Patients will be approached and screened in-person. Those completing genetic testing and the baseline survey will be randomized to the precision versus standard intervention for each risk level with a target sample size of 286 for each combination. Primary outcomes of effectiveness, assessed at 6 and 12&#xa0;months, include a tanning score (5 items assessing intentional and unintentional tanning), number of sunburns, conduct of a skin self-examination, and electronic health record documentation of clinician-patient communication about skin cancer prevention. Effectiveness comparisons will focus on the precision relative to the standard intervention among higher risk participants. Implementation data will be collected to identify barriers and facilitators. RESULTS: Effectiveness and implementation outcomes will be evaluated following study completion. CONCLUSIONS: Results will guide subsequent scale-up of the precision intervention, including modifications of the intervention as well as methods for implementation. CLINICAL TRIALS IDENTIFIER: NCT07222995.

Humans

What's the meta now? More updates on the problems with systematic reviews.

BACKGROUND: Systematic reviews are intended to provide trustworthy evidence synthesis, yet previous iterations of this living review have identified numerous recurring problems in their conduct and reporting. This article presents the third version and second update of the living systematic review examining issues raised across the academic literature. METHODS: Using consistent eligibility criteria and methods from earlier versions, literature searches were updated to May 2025. Eligible meta-research and editorial articles describing problems with systematic reviews were analyzed to identify emerging themes. Additionally, four basic indicators of methodological quality of the included meta-research were presented across review versions. RESULTS: The update included 209 additional articles. Critically low methodological quality and absence of protocols remained among the most frequently reported issues in systematic reviews across disciplines and journals but notably in evidence underpinning clinical practice guidelines. Spin in abstracts and conflicts of interest continued to be common. Apparent improvements in reporting quality were inconsistent, with modest gains in some full-text reporting but persistent deficiencies in abstracts. Authorship diversity of systematic reviews improved in gender representation but remained geographically concentrated in high-income countries, and primary research included in reviews similarly lacked global representativeness. The issue of misalignment between systematic review evidence bases and global burden of disease bring the total number of problems with systematic reviews to 69. Emerging use of automation and artificial intelligence was variably reported. Descriptive comparison of meta-research articles over the three versions of this living review suggests a greater proportion meeting basic quality indicators in more recent updates. CONCLUSION: Across successive updates, problems with systematic reviews remain widespread and consistent rather than isolated. Incremental reporting improvements coexist with persistent concerns about transparency, bias, and representativeness. Future efforts should prioritize evaluating interventions and aligning research incentives to support genuinely trustworthy evidence synthesis.

Humans

Physical reconfiguration of limb electrodes for Precordial Bipolar Lead acquisition: Morphological validation against digital subtraction.

BACKGROUND: The V2&#xa0;-&#xa0;V1 Precordial Bipolar Lead (PBL) selectively evaluates the right-to-left retrosternal axis and has shown diagnostic value beyond the standard 12&#x2011;lead electrocardiogram. However, its use has been limited by the need for raw electrocardiographic data and post-processing software. This study evaluated whether a simple physical reconfiguration of limb electrodes could reproduce the digitally derived V2&#xa0;-&#xa0;V1 morphology with sufficient accuracy for clinical application. METHODS: Thirty-seven subjects underwent two sequential 10-s 12&#x2011;lead recordings using a Cardiovit FT-1 electrocardiograph sampled at 1000&#xa0;Hz. In the standard recording, the digital PBL was calculated as V2&#xa0;-&#xa0;V1. In the second recording, the right-arm and left-arm electrodes were repositioned to the V1 and V2 sites so that Lead I directly recorded the retrosternal dipole. Signals were filtered, synchronized, and analyzed using median beats. Morphological agreement was assessed with Pearson correlation on Z-normalized signals, while absolute agreement was evaluated using Lin's concordance correlation coefficient (CCC), intraclass correlation coefficient (ICC (Lewis, 1931; Nehb, 1938 [1,2])), root mean square error (RMSE), and Bland-Altman analysis. RESULTS: Mean Pearson correlation between digital and physical PBL was 0.955 (SD 0.043), with segment-specific correlations of 0.953 (SD 0.054) for QRS and 0.967 (SD 0.052) for ST-T. Lin's CCC and ICC(2,1) were both 0.871 (SD 0.110), and RMSE was 0.091 (SD 0.049) mV. Bland-Altman analysis showed minimal bias (-0.008&#xa0;mV). CONCLUSIONS: Physical acquisition of the V2&#xa0;-&#xa0;V1 PBL achieved high agreement with the digitally derived signal, supporting a simplified analog method for broader clinical implementation.

Humans

Ageing effects on chemical, physical, mechanical, and morphological properties of clear aligners - a systematic review.

BACKGROUND: Clear aligner (CA) therapy has experienced rapid use over the past two decades to treat orthodontic malocclusions. However, evidence on CA material degradation in the oral environment remains limited and often focuses on single brands or isolated material properties. OBJECTIVES: To investigate CA ageing characteristics across different materials and brands and evaluate the chemical, physical, mechanical, and morphological changes following simulated or intraoral ageing. SEARCH METHODS: Five databases (PubMed, Web of Science, MEDLINE [Ovid], ProQuest, and Scopus) were searched to 18 March 2026, with no restrictions. ELIGIBILITY CRITERIA: Studies assessing CA properties after intraoral use or simulated ageing (thermocycling, cyclic loading, or liquid immersion) were included. DATA COLLECTION AND ANALYSIS: Study selection followed PRISMA 2020. RoB was assessed using QUIN for purely in vitro studies, JBI for cohort in vivo studies, and Cochrane RoB 2 for RCTs. Results were synthesised narratively and organised by property domain, as substantial methodological heterogeneity precluded formal meta-analysis. Where protocols were comparable, a simple pooled weighted mean was calculated and presented graphically. RESULTS: Ninety-five studies were included. RoB was low in eight studies, moderate in sixty-two, and high in twenty-five. Chemical composition remained largely stable during ageing, though some brands showed trace elemental release. Physical, mechanical, and morphological properties showed material-dependent deterioration. Pooled discolouration was greatest with coffee (weighted mean &#x394;E&#x2009;=&#x2009;70.9), versus tea (&#x394;E&#x2009;=&#x2009;18.4) and red wine (&#x394;E&#x2009;=&#x2009;11.5), with Invisalign&#xae; consistently exceeding the clinically perceptible threshold. Force decay of 40-90% typically occurred within 48&#xa0;h. Thermoplastic polyurethane (TPU)-based and directly printed aligners (DPAs) generally showed greater susceptibility than polyethylene terephthalate glycol-modified (PETG)-based aligners, though findings on hardness, roughness, and stiffness were inconsistent. CONCLUSIONS: CA materials undergo clinically relevant degradation during use, particularly in TPU-based and DPAs aligners. Clinicians may need to prioritise material-specific protocols, reinforce dietary and cleaning instructions, and consider force decay when determining aligner replacement intervals. PROSPERO number: CRD420251110248.

Humans

Anatomy and Biomechanics of the Deltoid Ligament Complex in Healthy Ankles: Protocol for a Systematic Review and Meta-Analysis.

INTRODUCTION: Up to one in two individuals who have a history of an ankle injury will develop chronic ankle instability, which subsequently increases the risk of osteoarthritis development. Although lateral ankle ligament injuries are the most common, recent research shows that concomitant injuries to the deltoid (medial collateral) ligament complex may be more prevalent than previously recognised. However, the anatomy and biomechanics of the deltoid ligament complex are reported inconsistently in the literature. This systematic review will summarise current evidence on the anatomy and biomechanics of the deltoid ligament complex in healthy adult ankles. METHODS: Searches will be conducted in Scopus, MEDLINE, Embase, CINAHL and SPORTDiscus. Our search strategy will cover terms associated with 'deltoid ligament', 'anatomy' and 'biomechanics'. We will only include dissection and imaging studies published in English that report any of the listed clinically relevant properties of the deltoid ligament in healthy adult human ankles. Two reviewers will independently perform screening and assess study quality using the anatomical quality assessment (AQUA) tool. One reviewer will extract relevant data, which will be independently verified by co-authors. Primary outcomes include band prevalence, length, width, cross-sectional area, maximum and/or failure load and elastic modulus. If three or more studies report a primary outcome, we will conduct a meta-analysis and report findings as pooled means with 95% confidence intervals. If a meta-analysis is not feasible, outcomes will be summarised as a narrative analysis. Measures will be taken during data synthesis to address anticipated methodological heterogeneity across included studies, and pooled estimates will be interpreted with caution. DISCUSSION: This protocol details a systematic review that aims to summarise the anatomy and biomechanics of the deltoid ligament complex. Our findings will inform computational modelling, clinical management and biomechanics for ankle pathologies, as well as identifying research gaps and directions for future research. TRIAL REGISTRATION: PROSPERO: CRD420251142867.

Humans

Comparative efficacy and safety of bi-flanged metal stents versus lumen-apposing metal stents for endoscopic drainage of pancreatic fluid collections: a systematic review and meta-analysis.

INTRODUCTION: Pancreatic fluid collections (PFCs), particularly walled-off necrosis, are common complications of acute pancreatitis that often require endoscopic drainage. Bi-flanged metal stents (BFMS; NAGI; Taewoong Medical, Gyenoggi-do, Korea) and electrocautery-enhanced lumen-apposing metal stents (LAMS; AXIOS, Boston Scientific Corporation, Marlborough, Massachusetts, USA) are frequently used, but comparative data remain limited. This study aims to compare the efficacy and safety of BFMS and LAMS in the endoscopic drainage of PFCs. METHODS: This meta-analysis followed the Cochrane Handbook for Systematic Reviews of Interventions and Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Comprehensive database searches were conducted through November 2024 to identify studies comparing BFMS and LAMS for endoscopic ultrasound-guided drainage of PFCs. Outcomes were pooled using a random-effects model with RevMan Web, and statistical significance was defined as a P value less than 0.05. RESULTS: Three studies ( n &#x2005;=&#x2005;627; 329 BFMS and 298 LAMS) met inclusion criteria. No significant differences were observed between BFMS and LAMS for technical success [odds ratio (OR): 1.16; 95% confidence interval (CI): 0.55-2.43] or clinical success (OR: 0.97; 95% CI: 0.51-1.87). Similarly, there were no differences in walled-off necrosis recurrence (OR: 2.01; 95% CI: 0.17-24.02), number of direct endoscopic necrosectomy sessions (OR: 0.52; 95% CI: 0.05-5.12), or mean number of endoscopic procedures (mean difference: 0.18, 95% CI: 2.08-2.45). Adverse events were also comparable between groups, including bleeding (OR: 0.64), infection (OR: 1.18), stent migration (OR: 1.83), and stent occlusion/dysfunction (OR: 1.71). CONCLUSION: BFMS and LAMS provide equivalent efficacy and safety in the endoscopic ultrasound-guided drainage of PFCs. Either stent type represents a viable therapeutic option. Further large-scale prospective studies are warranted to refine stent selection strategies.

Humans