605 records · Page 9Linked to original sources

Comprehensive analysis of mRNA-microRNA-lncRNA expression profiles in post-traumatic elbow heterotopic ossification using RNA sequencing and experimental validation.

BACKGROUND: This study aimed to profile the molecular signatures of post-traumatic elbow heterotopic ossification (HO) to identify key regulators and potential therapeutic targets. METHODS: Total RNA from post-traumatic elbow HO tissues (n=4) and normal bone tissues (n=6) was subjected to high-throughput sequencing to identify differentially expressed mRNAs (DEGs), microRNAs (DEMs), and lncRNAs (DELs). Bioinformatics analyses included Gene Ontology (GO), Kyoto Encyclopedia of Genes and Genomes (KEGG) pathway enrichment, protein-protein interaction network construction, and transcription factor (TF)-microRNA-mRNA network analysis. The expression trends of four most upregulated and four most downregulated DEGs were validated by real-time quantitative reverse transcription polymerase chain reaction (qRT-PCR). RESULTS: We identified 2,138 DEGs, 40 DEMs, and 905 DELs. DEGs were significantly enriched in biological process "bone mineralization," cellular component "plasma membrane," molecular function "integrin binding," and pathways including PI3K-Akt, NF-κB, JAK-STAT, and TNF signaling pathways. Hub genes with high connectivity included MMP9, IL6, MMP3, CTSK, and BGLAP. Integrated network analysis highlighted the transcription factor JUN and key microRNAs (hsa-miR-124-3p, hsa-miR-548c-3p, and hsa-miR-135b). The qRT-PCR results confirmed the expression trends of selected DEGs. CONCLUSIONS: This study, for the first time, profiled the differentially expressed mRNAs, microRNAs, and lncRNAs in post-traumatic elbow HO using high-throughput RNA sequencing. These findings provide valuable insights into the molecular mechanisms of HO following elbow trauma. The identified hub genes (MMP9, IL6, MMP3, CTSK, and BGLAP), key TF (JUN), and key microRNAs (hsa-miR-124-3p, hsa-miR-548c-3p, and hsa-miR-135b) may serve as potential therapeutic targets for preventing and treating post-traumatic elbow HO.

Humans

Safety and efficacy of distal versus conventional radial artery cannulation for invasive blood pressure monitoring: a systematic review and meta-analysis.

To compare the safety and effectiveness of distal radial artery (DRA) versus conventional radial artery (CRA) catheterization for invasive arterial blood pressure monitoring. This meta-analysis followed PRISMA guidelines. Randomized controlled trials published up to December 30, 2025 were systematically searched in PubMed, Embase, Web of Science, the Cochrane Library, CINAHL, CNKI, Wanfang, VIP, and SinoMed. Two reviewers independently screened studies, extracted data, and assessed risk of bias. Meta-analyses were conducted using Review Manager 5.4 and Stata 18.0, and evidence quality was evaluated with the GRADE system. 12 randomized controlled trials (RCTs) involving 1,790 participants were included. For the primary outcomes, compared with CRA, DRA was associated with lower incidences of haematoma (RR = 0.42, 95% CI: 0.24-0.73), catheter blockage (RR = 0.33, 95% CI: 0.14-0.81), and bleeding (RR = 0.25, 95% CI: 0.11-0.59), but a longer catheter insertion time (MD = 26.89, 95% CI: 5.28-48.50). For the secondary outcomes, DRA was associated with a shorter haemostasis time and reduced waveform instability, with no significant differences in first-attempt success rate or pain scores. Subgroup analysis showed a higher first-attempt success rate in patients aged ≤ 65 years (RR = 1.14, 95% CI: 1.02-1.28). DRA catheterization for invasive arterial blood pressure monitoring appears to be associated with fewer complications and more stable arterial waveform acquisition than CRA catheterization, despite a longer insertion time. DRA may represent a feasible alternative in surgical and intensive care settings; however, further high-quality studies are needed to confirm its long-term safety and generalizability.

Humans

A systematic approach to standardizing the visual appearance of endometriotic lesions for artificial intelligence recognition.

INTRODUCTION: Numerous studies have shown that the diagnostic performance and reproducibility of visual recognition of endometriosis during laparoscopy are poor. The use of artificial intelligence (AI) seems relevant for exhaustive lesion recognition. Standardization of the visual classification of lesions, in the form of an ontology, is an essential prerequisite to enable medical experts to annotate surgical data consistently and subsequently allow engineers to train and build an artificial intelligence tool for endometriosis recognition. MATERIAL AND METHODS: A systematic search was conducted in the MEDLINE (via PubMed), EMBASE, and the Cochrane Library databases up to May 2022, aiming to identify studies describing the laparoscopic visual appearance of superficial endometriosis, endometriomas, and deep infiltrating endometriosis. The accumulated data in the literature concerning the visual appearance of the different forms of endometriosis were used to create an ontology that could be used for artificial intelligence applications. RESULTS: Out of 932 articles screened, 35 studies were selected based on the inclusion criteria of human subjects with histologically confirmed endometriosis lesions visualized via laparoscopy. The selected studies were reviewed to develop a visual ontology of endometriosis lesions observed via laparoscopy. The lesions were categorized into 4 classes and further subdivided into 11 subclasses: superficial (black, red, white, or subtle), adhesions (dense or filmy), deep (obliteration, retraction, or deformation), and ovarian (endometrioma or chocolate fluid). The positive predictive value (PPV) varied across lesion types: black lesions (PPV 47%-97%), red lesions (PPV 33%-100%), white lesions (PPV 20%-81%), and ovarian endometriosis (PPV 42%-98%). Nonspecific lesions such as adhesions (PPV 16%-50%) and subtle superficial lesions (PPV 0%-67%) presented lower PPVs. Deep endometriosis lesions, often buried within organs, required indirect signs (obliteration, retraction, deformation) for identification. CONCLUSIONS: The visual ontology proposed in this systematic search could facilitate the detection and classification of endometriosis lesions using artificial intelligence. This study highlights the challenges of reaching a consensus on lesion recognition and classification in AI projects due to the diverse visual presentations of endometriosis.

Humans

Delphi study robot consenso: Strategies for the implementation of robotic surgery in general surgery in the Spanish hospital network.

INTRODUCTION: The implementation of robotic surgery in public hospitals presents multiple logistical, educational, and organizational challenges. In the absence of unified guidelines, a national consensus is required to optimize its safe and efficient adoption. This study aimed to establish a set of consensus-based and measurable recommendations for the implementation of robotic surgery programs in hospitals within the Spanish National Health System, based on the experience of centres with established robotic programs and intended to serve as guidance for hospitals that are initiating or planning their implementation. METHODS: A national Delphi study was conducted with the participation of robotic surgery experts from 26 public hospitals. The expert panel was composed exclusively of digestive surgeons with experience in robotic surgery. Three iterative rounds of expert panel evaluation were conducted between March 2024 and March 2025. The questions were grouped into five thematic blocks. Consensus was defined as an agreement level of ≥66.7%. Kendall's W coefficient was used to assess concordance. RESULTS: High levels of consensus were achieved on key aspects related to infrastructure, structured training, cost evaluation, and quality assurance mechanisms. Areas of disagreement were also identified, such as the need for a dedicated anaesthesiologist, purchase of accessory instruments during the initial phase, and official accreditation pathways. CONCLUSIONS: This study provides a guideline for developing a national robotic surgery strategy focused on patient safety, program sustainability, and standardized training of surgical teams. These recommendations can guide hospitals at different stages of robotic technology adoption. Given that the consensus was reached from an exclusively surgical perspective, the recommendations focus on patient safety, program sustainability, and standardized training of the surgical team, and should be interpreted in an adaptable manner according to each centre's context, case volume, and available resources.

Cirugía Asistida por Robot

Machine learning vs. traditional methods for predicting postoperative cardiac complications after non-cardiac surgery: a systematic review and Bayesian network meta-analysis.

INTRODUCTION: Accurate prediction of peri-operative cardiac complications is critical to optimise pre-operative decision-making. Traditional risk prediction scores, such as the Revised Cardiac Risk Index, show only modest discrimination. Machine learning can model complex, non-linear relationships but their predictive performance compared with traditional scores remains unclear. METHODS: We performed a systematic review and Bayesian network meta-analysis. The primary outcome was postoperative adverse cardiac events following non-cardiac surgery. Prediction models were assessed relative to the Revised Cardiac Risk Index. As many studies evaluated multiple versions of each model type, the highest performing ('best version') and lowest performing ('worst version') results were analysed. Models were ranked using the surface under the cumulative ranking curve (SUCRA). RESULTS: Thirteen studies evaluating 54 models and 927,113 patients were included. Machine learning approaches generally outperformed traditional risk scores. Automated machine learning ranked highest (SUCRA 96.6) showed the greatest improvement in the best version analysis (mean difference (MD) 0.28 (95%CrI 0.16-0.40)) and remained superior in the sensitivity analysis (MD 0.30 (95%CrI 0.14-0.45)). Gradient boosting models showed superior performance over the Revised Cardiac Risk Index across analysis (best version: MD 0.20 (95%CrI 0.14-0.26), worst version: MD 0.18 (95%CrI 0.12-0.25), SUCRA 82.4). The Gupta Perioperative Risk for Myocardial Infarction or Cardiac Arrest score outperformed the Revised Cardiac Risk Index in the best version analysis (MD 0.16 (95%CrI 0.01-0.32)). Between-study heterogeneity was low. None of the included studies externally validated their machine learning models and only six were judged to be at low risk of bias. DISCUSSION: Most machine learning models showed better discrimination than traditional risk scores, with automated machine learning and gradient boosting models ranking highest. However, study quality, calibration reporting and absence of external validation limit immediate clinical adoption. Prospective, multicentre evaluation is required before integration of these models into peri-operative practice.

Humans

Automated CEAP Classification of Venous Duplex Reports Using Multimodal Artificial Intelligence.

OBJECTIVE: To develop and internally validate a prototype multimodal artificial intelligence system for automated CEAP (Clinical, Etiological, Anatomical and Pathophysiological) classification of venous duplex ultrasound (VDUS) reports, integrating natural language processing of free-text components with computer vision analysis of hand-drawn anatomical diagrams. METHODS: Single centre retrospective observational study using routinely collected clinical data. One thousand consecutive venous duplex ultrasound reports from Cambridge University Hospitals NHS Foundation Trust, UK (July 2024 - May 2025) were labelled according to the CEAP classification, excluding the Etiological component, which could not be reliably determined from duplex reports alone. Transfer learning was applied using ClinicalBERT for text and MobileNetV3 for diagrammatic data. Clinical classes were predicted from request line text. Text- and image-based pathophysiological models were developed for four anatomical territories (Great Saphenous Vein, Small Saphenous Vein, Deep system, Perforators), combined using late fusion with probability averaging. RESULTS: The clinical CEAP model achieved accuracy of 0.91, macro-F1 of 0.82, and macro-AUC of 0.98. Pathophysiological prediction varied, with text models broadly outperforming image models. Fusion yielded heterogeneous benefits, improving SSV performance but reducing Deep system accuracy. The performance of the final pathophysiological CEAP fusion models varied across anatomical territories: accuracy ranged from 0.70-0.92 and macro-AUC from 0.80-0.92. CONCLUSION: This study demonstrates the feasibility of automated CEAP classification from VDUS reports. Despite class imbalance affecting minority class predictions, the strong discriminatory performance validates this multimodal ML model for extracting clinically meaningful information from real-world data. This approach offers potential, pending external validation, to streamline vascular services through automated triage and guideline-compliant decision making.

Artificial intelligence

Application of SPI-guided analgesia in laparoscopic gynecologic surgery: a randomized controlled trial evaluating the remifentanil-sparing effect and predictive value of time-weighted SPI.

This study aimed to achieve two primary objectives: (1) to evaluate the opioid-sparing effect of Surgical Pleth Index (SPI)-directed analgesia during surgery via a randomized controlled trial (RCT), and (2) to propose and preliminarily assess a novel dynamic metric, Threshold-based Time-Weighted SPI (Tb-TW-SPI), which integrates stimulus intensity and duration, for its predictive efficacy regarding postoperative moderate-to-severe pain. Employing an RCT combined with exploratory analysis, 61 patients undergoing elective laparoscopic gynecologic surgery were randomized into an SPI-directed analgesia group or a conventional analgesia group. The primary outcome was total intraoperative remifentanil consumption. Postoperatively, an exploratory analysis of the control group data evaluated the correlation between Tb-TW-SPI and Numeric Rating Scale (NRS) pain scores in the post-anesthesia care unit (PACU), calculating its predictive value for moderate-to-severe pain (NRS ≥ 4). Results: The SPI-directed group required significantly less intraoperative remifentanil than the conventional group [median (IQR): 5.84(5.02,6.62)vs. 6.96(5.81,8.19)µg/kg/h; P = 0.016]. Postoperative pain scores did not differ significantly between groups (P > 0.05). Exploratory analysis of the conventional analgesia group revealed that Tb-TW-SPI values were significantly higher in patients with moderate-to-severe postoperative pain (NRS ≥ 4) compared to those without (P = 0.0417).The area under the ROC curve for Tb-TW-SPI predicting this pain was 0.74 (95% CI: 0.52-0.96), with 67% sensitivity and 76% specificity at an optimal cutoff of 1210. This RCT suggests that SPI-directed analgesia can safely and moderately reduce intraoperative remifentanil consumption. Furthermore, the proposed Tb-TW-SPI metric, in this exploratory analysis, suggests potential for predicting postoperative pain, though this finding requires validation in larger cohorts with higher-frequency SPI sampling, offering a new direction for SPI interpretation. Large-scale, multicenter trials are warranted to validate the predictive utility of Tb-TW-SPI. Clinical Trial Registration, China Clinical Trial Registry: ChiCTR2400088444.

Humans

Closed-loop vasopressor systems for hemodynamic control in perioperative and critical care settings: a systematic review and meta-analysis.

Maintaining mean arterial pressure (MAP) within a predefined target is central to haemodynamic management in surgical and critically ill adults receiving vasopressors. Closed-loop vasopressor (CLV) systems automate titration to optimise blood pressure control, but their clinical effectiveness remains uncertain. We performed a systematic review and meta-analysis comparing CLV with manual titration. This PRISMA 2020-compliant review was prospectively registered in PROSPERO (CRD420250655697). MEDLINE, Embase, Scopus, Web of Science, CENTRAL, and the Cochrane Library were searched (January 2000-June 2025). Randomised controlled trials enrolling adults receiving vasopressors in perioperative or intensive care settings were included. Primary outcomes were time within the MAP target range and time spent in hypotension or hypertension. Risk of bias was assessed using RoB 2.0 and certainty of evidence using GRADE. Random- or fixed-effects models were selected according to heterogeneity. Six randomized controlled trials (215 patients) were included in the systematic review, whereas five perioperative trials contributed to the meta-analysis of haemodynamic control outcomes, and one ICU-based study was summarized narratively because it did not report comparable MAP control endpoints. CLV increased time within the MAP target range (mean difference [MD] 33.94%, 95% CI 20.41-47.46; I2 = 77%) and reduced time in hypotension (MD - 18.24%, 95% CI - 28.95 to - 7.53; I2 = 73%). There was no significant difference in time in hypertension, cumulative norepinephrine dose, or major/minor adverse events. ICU length of stay was not pooled because of clinical and methodological heterogeneity. Certainty of evidence ranged from low to high (moderate for haemodynamic control outcomes). CLV systems improved haemodynamic control, primarily in perioperative settings, but heterogeneity and small samples limit confidence in effect size and generalisability. Evidence in critically ill populations remains limited, and larger trials are needed to determine whether improvements in these physiological surrogate endpoints translate into meaningful patient-centred outcomes.

Humans

Molecular characterization and biological characteristics of a highly pathogenic recombinant ALV-J strain (HUE2023) with cross-clade gp85 recombination.

Avian leukosis virus subgroup J (ALV-J) has undergone extensive diversification into phylogenetically distinct clades, yet whether recombination between these clades within the gp85 envelope glycoprotein generates variants with altered pathogenicity has received little direct investigation. A field strain (HUE2023) was recovered from breeding roosters displaying vascular tumors. The viral genome was sequenced and subjected to phylogenetic and recombination analyses. The three-dimensional structure of gp85 was predicted with AlphaFold3; electrostatic surface potentials and surface hydrophobicity were computed using the Adaptive Poisson-Boltzmann Solver and the Eisenberg hydrophobicity scale, respectively. Pathogenicity and immunosuppressive effects were assessed in Hy-Line Brown chickens. Recombination analysis revealed that HUE2023 is an inter-clade recombinant derived from Clade 1.1 (major parent: JS14NT01) and Clade 1.2 (minor parent: JS09GY3). A single-residue deletion at position 61 within receptor-binding domain 1 (RBD-1), unique to the recombinant, induced a localized conformational rearrangement that generated a concentrated electronegative surface patch and a contiguous hydrophobic pocket not observed in either parental gp85. Animal challenge showed that HUE2023 is highly pathogenic: female chickens in the high-dose group reached only 61% survival and displayed significant growth retardation (P&#x202f;<&#x202f;0.05) together with marked immunosuppression. The recombination in the RBD-1 led to local conformational rearrangement, resulting in a concentrated and negatively charged surface area as well as a continuous hydrophobic pocket, which were never present in any of the parental gp85 sequences. These results indicate that gp85 recombination across clades can yield variants with fundamentally altered receptor-binding surfaces and argue for integrating structural surveillance into ALV-J monitoring programmes.

Animals

Diagnostic Performance of Machine Learning for Systemic Lupus Erythematosus: Systematic Review and Meta-Analysis.

BACKGROUND: Early and accurate diagnosis of systemic lupus erythematosus (SLE) and its organ involvement is essential. Previous reviews of machine learning (ML) in SLE combined heterogeneous tasks and validation strategies and may have overinterpreted model performance. OBJECTIVE: This study evaluated the diagnostic performance of ML and deep learning (DL) models for 3 clinically distinct SLE-related tasks: SLE classification or diagnosis, lupus nephritis (LN) diagnosis, and neuropsychiatric systemic lupus erythematosus (NPSLE) discrimination. We also assessed methodological quality and certainty of evidence. METHODS: PubMed, Embase, Cochrane Library, Web of Science, and IEEE Xplore were searched from January 2014 to April 2026. Eligible peer-reviewed diagnostic accuracy studies developed or validated ML or DL models for 1 of the 3 prespecified tasks, used an accepted reference standard, and provided data for a 2&#xd7;2 contingency table. Bivariate random-effects meta-analyses with the Hartung-Knapp-Sidik-Jonkman adjustment were used to pool sensitivity and specificity. We reported 95% prediction intervals (PIs), assessed risk of bias using the Quality Assessment of Diagnostic Accuracy Studies for Artificial Intelligence tool (QUADAS-AI; Viknesh Sounderajah [Imperial College London]), and evaluated certainty of evidence using the Grading of Recommendations Assessment, Development, and Evaluation framework for diagnostic test accuracy. RESULTS: Twenty-nine studies were included: 17 for SLE classification, 5 for LN diagnosis, and 7 for NPSLE discrimination. In the primary task-stratified analysis, pooled sensitivity was 0.91 (95% CI 0.86-0.94; 95% PI 0.56-0.99), and pooled specificity was 0.94 (95% CI 0.91-0.96; 95% PI 0.69-0.99), with low heterogeneity (I&#xb2;=23.9% and 22.9%, respectively). DL models showed a sensitivity of 0.93 and specificity of 0.95, compared with 0.88 and 0.94 for traditional ML models. Certainty of evidence was high for most analyses but low for LN diagnosis because of inconsistency and imprecision. All studies were retrospective, and only 9 of 29 (31%) performed independent external validation. Overall risk of bias was high or unclear in 22 of 29 (75.9%) studies. No study reported model calibration, decision-curve analysis, or net clinical benefit. CONCLUSIONS: ML models showed promising diagnostic accuracy across 3 distinct SLE-related tasks, but wide PIs, limited external validation, and pervasive risk of bias restrict conclusions about real-world generalizability. Prospective multicenter studies with standardized tasks and reference standards, independent external validation, and formal assessment of calibration and clinical utility are required before clinical implementation.

Humans

A randomized study of antibiotic prophylaxis after hypospadias repair in children.

BACKGROUND AND OBJECTIVE: Antibiotic resistance is a challenge in contemporary world. Urethroplasty for hypospadias is one of the most common urological surgeries performed around the world, yet, there is still no consensus on the use of antibiotics pre- and post-operatively. Our objective was to analyze the effectiveness of antibiotic prophylaxis and therapy before, during, and after hypospadias repair in children. METHODS: A prospective randomized trial was carried out including patients with coronal hypospadias who underwent urethroplasty performed by one surgeon. Urethral catheters were used in all cases for 10 days. Study participants were randomly assigned in a 1:1:1 ratio to receive a single intraoperative administration of antibiotics (Group I); an intraoperative antibiotic prophylaxis and antibiotic therapy for 10 days until the removal of urethral catheter (Group II); no antibiotic administration (Group III). Randomization was performed using computer-generated permuted blocks with randomly varying block sizes, prepared by an independent statistician. The results were analyzed using the analysis of variance (ANOVA). The following criteria were compared: postoperative functional complications, such as: urethral fistula, stenosis, diverticulum; wound infection symptoms: hyperemia of surgical site, pain during palpation, and symptomatic urinary tract infection. RESULTS: A total of 300 patients were included in the study. Two patients (2%) in Group I, two patients (2%) in Group II, and four patients (4%) in Group III had urethral fistulas, requiring surgery 6 months after primary repair, yet without statistical difference between groups. We found no significant difference in frequency of symptomatic UTIs between three groups (p = 0.182). CONCLUSION: There is no effect of antibiotic prophylaxis and therapy on the frequency of postoperative surgical and infectious complications after urethroplasty for coronal hypospadias repair in children.

Humans

Changes in hippocampal functional connectivity and volume associated with cognitive improvement and decline in amnestic mild cognitive impairment following computerized cognitive training.

BACKGROUND: The hippocampus influences the outcomes of amnestic mild cognitive impairment (aMCI) and undergoes different changes during the cognitive decline or recovery of aMCI compared to elderly individuals with normal cognition, which may reveal disease-dependent neurodegeneration or plasticity. We first aimed to investigate the hippocampal changes associated with cognitive changes in aMCI using a combined case-control study design. METHODS: In total, 50&#x202f;aMCI individuals and 50 healthy controls (HCs) were recruited in Shenyang, China, and separately randomized into training and control groups: aMCI training group, aMCI no training group, HC training group, and HC no training group. The aMCI and HC training groups received computerized cognitive training (CCT) thrice weekly for 12 weeks. Cognitive assessments and MRI data were collected at baseline and follow-up. RESULTS: The primary outcome was significant CCT&#xd7;diagnosis interaction effect on the change in cognitive performance as measured by clock drawing test (CDT) scores (F&#x202f;=&#x202f;4.322, P&#x202f;=&#x202f;0.041); this interaction was driven by CCT specifically in aMCI (F&#x202f;=&#x202f;4.465, P&#x202f;=&#x202f;0.038). Significant CCT&#xd7;diagnosis interaction effects of right-hippocampal FC changes were observed in the bilateral precuneus/cuneus (Pvoxel<0.05) driven by CCT in aMCI (F&#x202f;=&#x202f;5.429, P&#x202f;=&#x202f;0.023), and in the left superior temporal gyrus/middle temporal gyrus (STG/MTG, Pvoxel<0.05), driven by CCT of only in HCs (F&#x202f;=&#x202f;6.587, P&#x202f;=&#x202f;0.013). A significant interaction effect of left-hippocampal FC changes were observed in the right triangular part of the inferior frontal gyrus (IFGtriang, Pvoxel<0.05), driven by CCT in aMCI and HCs (F&#x202f;=&#x202f;6.550, P&#x202f;=&#x202f;0.013; F&#x202f;=&#x202f;7.097, P&#x202f;=&#x202f;0.010). No significant interaction effect on the change in hippocampal GMV was noted (P&#x202f;>&#x202f;0.05). CONCLUSION: CCT can improve the visuospatial ability of aMCI, which is reflected by the CDT scores. CCT can alter hippocampal FC in the bilateral precuneus/cuneus, the right IFGtriang, and the left STG/MTG. The hippocampal GMV is difficult to change in both HCs and aMCI during the cognitive decline. REGISTRATION NUMBER: ChiCTR1900026849. DATE OF REGISTRATION: 24 October 2019 NAME OF TRIAL REGISTRY: Chinese Clinical Trial Registry (ChiCTR).

Humans

Test-retest reliability of spatiotemporal, kinematic, and kinetic measures in marker-based 3D gait analysis: A systematic review.

BACKGROUND: Marker-based 3D gait analysis (3DGA) is widely used to quantify impairments and evaluate treatment effects. For longitudinal clinical interpretation, clinicians and researchers need reference values for inter-session measurement error. For this purpose, this systematic review synthesized Standard Error of Measurement (SEM) values for spatiotemporal, kinematic, and kinetic (moments) outcomes obtained from marker-based 3DGA studies. METHODS: PubMed and Scopus were searched (final search: 11 December 2025). Studies reporting inter-session test-retest SEM and/or MDC for steady-state overground or treadmill walking using marker-based motion capture were included. Two authors screened records and appraised methodological/reporting quality using a custom tool informed by COSMIN, GRRAS, and biomechanics-specific items. Due to heterogeneity, results were synthesized descriptively using study-level median SEM values, stratified by joint, plane, population (healthy, pathological, single subgroups), and walking condition. Minimal Detectable Change (MDC) values were computed for all available data. RESULTS: Thirty-four studies (762 participants, 44.2% females) were included, with substantially more evidence for overground than treadmill walking. Overground spatiotemporal outcomes showed low errors (walking speed SEM of 0.06 m/s; timing typically &#x2264;0.03 s; spatial parameters generally &#x2264;0.03 m). For joint kinematics during overground walking, median SEMs were 2.4&#xb0; (sagittal), 1.9&#xb0; (frontal), and 3.3&#xb0; (transverse). The corresponding joint-kinetic SEMs were approximately 0.06, 0.04, and 0.03 Nm/kg, respectively. Treadmill data followed similar patterns. SIGNIFICANCE: Marker-based 3DGA allows for accurate assessment of spatiotemporal, kinematic, and kinetic gait features. We provided detailed SEM/MDC lookup tables to support clinical decision-making. Results further offer a benchmark for validating emerging gait assessment technologies (e.g., markerless systems) against realistic limits of marker-based 3DGA.

Humans

Webcam-Based Real-Time Visual Feedback During Baduanjin Practice in Older Adults: 6-Week Pilot Randomized Study.

BACKGROUND: Baduanjin qigong is a traditional mind-body exercise used to support balance and physical health in older adults. Age-related changes in proprioception may make accurate self-directed performance difficult without external guidance. OBJECTIVE: The aim of this study is to explore whether webcam-based real-time visual feedback delivered during supervised laboratory sessions was associated with differences in webcam-derived 2D pose discrepancy and movement consistency during Baduanjin practice in older adults. METHODS: A total of 31 older adults were enrolled, and 28 participants with complete analyzable records were included in this complete-case dataset (feedback group, n=14; nonfeedback group, n=14). All sessions were conducted face-to-face in a supervised motion-analysis laboratory. Weekly 2D pose-discrepancy values were analyzed using a linear mixed-effects model with fixed effects for group, categorical week, and the group-by-week interaction and a participant-specific random intercept. Joint- and movement-specific participant-level 6-week means were analyzed exploratorily using Welch independent-samples t tests. Holm correction was applied across 24 exploratory contrasts (6 week-specific, 8 joint-specific, and 10 movement-specific comparisons), and Hedges g and 95% CIs were reported. Participant-specific weekly slopes and within-participant variability were additionally examined to directly assess longitudinal error drift. RESULTS: The linear mixed-effects model showed no significant group-by-week interaction (Wald &#x3c7;25=1.09; P=.96) and no significant overall week effect (Wald &#x3c7;25=6.40; P=.27). Averaged across 6 weeks, the feedback group had an estimated mean 2D pose discrepancy 1.20&#xb0; lower than the nonfeedback group (95% CI -2.38&#xb0; to -0.02&#xb0;; P=.046), although this marginal pilot finding was sensitive to an analytic approach. No week-specific contrast remained significant after Holm adjustment. Nominal right elbow, right shoulder, and right knee differences did not survive global Holm correction. Form 3 showed a lower mean discrepancy in the feedback group (mean difference -3.70&#xb0;, 95% CI -5.86&#xb0; to -1.54&#xb0;; Hedges g=-1.30; unadjusted P=.002; Holm-adjusted P=.04). Direct analyses of participant-specific slopes and within-participant SDs did not support a significant between-group difference in longitudinal error drift. CONCLUSIONS: In this small exploratory pilot study conducted under supervised laboratory conditions, the 6-week trajectories did not differ significantly between groups. A marginally lower average 2D pose discrepancy was observed in the feedback group across the 6 weeks, but no individual week- or joint-specific comparison remained significant after multiplicity adjustment. Form 3 was the only exploratory contrast that remained significant after global Holm correction. Direct longitudinal analyses did not demonstrate prevention of error drift. Larger studies using validated reference measurements, prespecified outcomes, and adequately powered longitudinal designs are required.

Humans

Ifebemtinib plus garsorasib in previously treated metastatic colorectal cancer with KRASG12C mutation: a multicentre, randomised, phase 1b/2 trial.

BACKGROUND: Ifebemtinib is a potent oral focal adhesion kinase inhibitor. Preclinical evidence supports combining ifebemtinib with the KRASG12C inhibitor garsorasib. This study aimed to evaluate this combination in KRASG12C-mutated solid tumours. METHODS: This multicentre, phase 1b/2 study had a phase 1b component to establish the recommended phase 2 dose and a phase 2 multitumour expansion component. In phase 1b, the safety and tolerability of ifebemtinib combined with garsorasib was assessed using a 3&#x2008;+&#x2008;3 design in KRASG12C-mutated solid tumours. No dose-limiting toxic effects were observed, and the recommended phase 2 dose was established as ifebemtinib 100 mg orally once daily plus garsorasib 600 mg orally twice daily. Here, we report the results of the cohort of previously treated KRASG12C-mutated metastatic colorectal cancer from phase 2 expansion. Eligible patients (aged &#x2265;18 years) who had histologically confirmed locally advanced or metastatic colorectal cancer harbouring the KRASG12C mutation, an Eastern Cooperative Oncology Group performance-status score of 0 or 1, and had disease progression after previous irinotecan-based or oxaliplatin-based combination therapy, were recruited from seven of nine participating tertiary hospitals in China. On the basis of the recommended phase 2 dose, phase 2 comprised a single-arm study to evaluate the safety and efficacy of ifebemtinib combined with garsorasib and an open-label, randomised study in which patients were randomly assigned (1:1) to receive ifebemtinib plus garsorasib or garsorasib alone, by use of centralised computer-generated block randomisation with no stratification. Investigators were masked to the block size. The primary efficacy endpoint of phase 2 was investigator-assessed objective response rate (Response Evaluation Criteria in Solid Tumours, version 1.1), assessed in the safety analysis set in the single-arm study and in all randomly assigned patients (intention-to-treat population) in the randomised study. At least six objective responses (safety analysis set) were required in the single-arm study to proceed to the randomised study. This study is registered with ClinicalTrials.gov, NCT06166836 and NCT05379946, and is active but not recruiting. FINDINGS: Between April 7, 2023 and Dec 13, 2024, 51 patients were enrolled in phase 2 (15 in the single-arm study and 36 in the randomised study). In the single-arm study, the median age was 53 years (IQR 39 to 63), nine (60%) patients were female, six (40%) were male, and all were Asian. In the randomised study, the median age was 51 years (IQR 42 to 59) in the combination group and 63 years (IQR 54 to 66) in the monotherapy group, 24 (67%) were female, 12 (33%) were male, and all patients were Asian. In the single-arm part, the confirmed objective response rate was 46&#xb7;7% (95% CI 21&#xb7;3 to 73&#xb7;4). Seven patients had partial responses, triggering progression to the randomised study. In the randomised study, the confirmed objective response rate was 38&#xb7;9% (95% CI 17&#xb7;3 to 64&#xb7;3) with the combination therapy versus 16&#xb7;7% (95% CI 3&#xb7;6 to 41&#xb7;4) with garsorasib alone (between-group difference 22&#xb7;2%, 95% CI -7&#xb7;7 to 49&#xb7;1; one-sided p=0&#xb7;068). In the single-arm study, grade 3 treatment-related adverse events occurred in four (27%) of 15 patients, and in the randomised study, grade 3 treatment-related adverse events occurred in six (33%) of 18 patients in the combination group and five (28%) of 18 in the garsorasib group. Grade 3 treatment-related adverse events occurring in at least two patients were diarrhoea (six [18%]), proteinuria (two [6%]), and intestinal obstruction (two [6%]) in patients treated with combination therapy (combined), and increased alanine aminotransferase and &#x3b3;-glutamyltransferase (two [11%] each) in patients treated with garsorasib alone. Serious adverse events occurred in ten (30%) patients in the combination group and in four (22%) patients in the monotherapy group. One patient in the garsorasib monotherapy group died due to the underlying malignancy within 30 days after completing study treatment, which was reported as a serious adverse event. The death was assessed by the investigators as not related to garsorasib. No grade 4 treatment-related adverse events or treatment-related deaths were reported across all cohorts. INTERPRETATION: The combination of ifebemtinib and garsorasib showed promising anticancer activity and manageable safety profile in previously treated patients with KRASG12C-mutated metastatic colorectal cancer. Although the improvement in response rate did not reach statistical significance in the randomised study, these findings support further evaluation of ifebemtinib plus garsorasib in this population. FUNDING: InxMed, InventisBio, National Natural Science Foundation of China, the Jian Bing Ling Yan + X Research and Development Program of Zhejiang Province, and the Zhejiang Province Medical and Health Science and Technology Plan Project.

Humans

Comprehensive source-risk assessment of organophosphate esters in surface water of the Dianchi Lake Basin, Yunnan, China.

Organophosphate esters (OPEs), widely used as flame retardants and plasticizers, have been increasingly detected in aquatic environments. However, investigations of their distribution in high-altitude plateau lakes remain scarce. Identifying and quantifying the sources and associated risks of OPEs are crucial for subsequent water environment management. In this study, an integrated source-risk analysis approach was employed by combining the Positive Matrix Factorization (PMF) model, the Geodetector (GD) model, and risk quotient (RQ). Analysis of 14 OPEs in surface waters of the Dianchi Lake Basin (DLB) revealed 12 detectable compounds, with total OPEs concentrations (&#x3a3;OPEs) ranging from not detected (ND)-64.6 ng/L during the wet season and ND-35.8 ng/L during the dry season. Elevated &#x3a3;OPEs were primarily observed at inflow sites in the northern part of the lake and in urban rivers. Source apportionment indicated four major contributing sources: agricultural films containing flame-retardant and plasticizer additives, traffic-related particulate emissions, releases from household and personal care products, and industrial production and applications of flame retardants in plastics, electronics, and related products (the predominant source). The ecological impact caused by OPEs ranges from no risk to low risk, with tris(2-chloroethyl) phosphate emitted from industrial source being the primary driver of potential environmental risk. These findings highlight the necessity of prioritizing industrial sources in future management strategies. Overall, this study provides a methodological framework for source apportionment and risk assessment of OPEs and offers scientific evidence to support environmental management of OPEs in the DLB.

Environmental Monitoring

Pollution characteristics and health risks of PAHs and OPAHs in PM2.5 of an inland basin city in China under the influence of the clean air action plan.

Since the implementation of China's Clean Air Action, remarkable progress has been made in air pollution control, with continuous air quality improvement in Xi'an, a typical inland basin city in the Fenwei Plain. To clarify winter organic aerosol pollution variations and pinpoint targeted control needs under policy regulation, this study investigated PM2.5-bound polycyclic aromatic hydrocarbons (PAHs) and oxygenated derivatives (OPAHs) in winter Xi'an, focusing on pollution levels, chemical compositions, source contributions, meteorological impacts, regional transport and health risks. Historical comparison showed generally lower wintertime PAH concentrations in Xi'an during the period of China's clean-air actions. PMF results indicated mixed source influences on PAHs and OPAHs, with biomass-burning-related mixed combustion showing the largest contribution. During haze episodes, absolute concentrations of both PAHs and OPAHs increased; the increase was statistically significant for OPAHs but not for parent PAHs, while 4-5 ring PAHs and BcdPQ dominated the PAH and OPAH profiles, respectively. Meteorological variability, particularly synoptic pressure patterns, was strongly associated with pollutant concentrations, and regional pollution was dominated by in-basin accumulation combined with short-range transport from northern Shaanxi industrial zones. Haze periods exhibited higher toxic-equivalent concentrations, with OPAHs, particularly BcdPQ, dominating the toxicity-equivalent burden. Screening-level ILCR estimates generally remained below 10&#x207b;4 but increased during haze episodes, especially for adult and elderly groups. In conclusion, China's clean air actions have coincided with lower wintertime PAH pollution, but stronger control of residential biomass and other solid-fuel combustion, traffic emissions, and OPAH formation remains necessary in the Fenwei Plain.

China

Quantifying the combined effects of semi-closed terrain and monsoon on PM2.5 and O3 pollution aggregation in the North China Plain.

The North China Plain (NCP) and its surrounding regions represent one of the key priority areas for air pollution control. As anthropogenic emissions decline significantly, the effect of terrain and meteorology on air pollution pattern has become increasingly prominent, particularly given the NCP's unique semi-closed terrain and East Asian monsoon dynamics. However, quantitative characterization of terrain-dominated blocking effects remains unexplored. Here we quantitatively assess the blocking effects of mountains and terrain-coupled meteorological factors on air pollutant dispersion. We find the NCP on the eastern side of the Taihang Mountains showed high PM2.5 and O3 pollution levels, with winter PM2.5 and summer O3 high-value zones showing opposite north-south aggregation patterns. PM2.5 and O3 concentrations were highest in plains, followed by platforms, hills, and finally mountains. Within the 120-km buffer zones of the typical mountains in the NCP and its surrounding regions, PM2.5 and O3 concentrations increased initially with altitude but then decreased markedly above a threshold altitude. Above the threshold altitude, mountain blocking effects became dominant. The effective blocking altitudes of typical mountains in the NCP and its surrounding regions ranged between 22 and 929 m for winter PM2.5 pollution, and between 19 and 1060 m for summer O3 pollution. The Terrain-Wind Close Index indicates that the terrain-coupled East Asian monsoon showed stronger blocking effects on PM2.5 dispersion in southern NCP during winter and on O3 diffusion in northern NCP during summer, matching observed high-pollution zones. This study offers key insights for regional joint air pollution mitigation strategies, as well as regional pollution assessment.

Particulate Matter