Search PubMedSearch

SEARCH · Search PubMed

Results for “Cardiac magnetic resonance imaging”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

315 records · Page 9Linked to original sources

The role of media in reducing and reinforcing stigma: A randomized controlled trial investigating the impact of positive and negative representations of visible difference.

OBJECTIVES: Individuals with visible differences often experience appearance-related stigma and discrimination, reinforced by negative media portrayals. In contrast, positive portrayals may challenge stereotypes and promote acceptance. This study examined whether exposure to positive, negative or neutral images of visible difference influences appearance-related stigma, body appreciation and broad conceptualizations of beauty. It was hypothesized that positive images would decrease stigma and increase body appreciation and broad conceptualizations of beauty, whereas negative images would increase stigma and reduce broad conceptualizations of beauty. DESIGN: An online randomized controlled experiment using a mixed repeated-measures design compared three conditions (positive, negative, neutral) across pre- and post-exposure. METHODS: A sample of 103 adults viewed 10 images of individuals with visible differences presented in one of three conditions: positive (positive captions), negative (villains with visible differences and negative captions) or neutral (without captions). Participants completed pre- and post-measures of appearance-related stigma, body appreciation and broad conceptualizations of beauty. Repeated-measures ANOVAs examined within- and between-group changes. RESULTS: Appearance-related stigma significantly increased in the negative condition, while remaining unchanged in the positive and neutral groups. Body appreciation significantly increased from pre- to post- across all conditions. No significant effects emerged for broad conceptualizations of beauty. CONCLUSIONS: Negative portrayals of visible difference may reinforce stigma, highlighting the need to discourage such depictions in media. While positive exposure did not significantly reduce stigma, viewing images of visible difference increased observers' body appreciation, indicating potential downward social comparison. Future research should explore strategies to strengthen stigma reduction and broaden conceptualizations of beauty.

Humans

Cardiovascular Drug Access in Australia and New Zealand: New PBS and PHARMAC Listings, 2023-2025.

BACKGROUND: Cardiovascular disease is a leading cause of death in Australia and New Zealand. Publicly subsidised access to new cardiovascular medications is governed by the PBS (Pharmaceutical Benefits Scheme) in Australia and PHARMAC (Pharmaceutical Management Agency) in New Zealand, yet no consolidated resource catalogues recent listings across both jurisdictions. METHODS: We reviewed all new cardiovascular drug listings and indications on the PBS and PHARMAC schedules from 1 January 2023 to 31 December 2025. PBS data were obtained from the PBS Pricing and Policy Branch through the Cardiac Society for Australia and New Zealand. PHARMAC data were obtained via direct communication with PHARMAC and cross-referenced with public schedule information. Pivotal trial evidence, restriction criteria, and prescribing considerations were extracted from published literature and regulatory documents. RESULTS: Five new cardiovascular drugs were PBS-listed (inclisiran, mavacamten, tafamidis, icosapent ethyl and migalastat), two existing drugs received new cardiovascular indications (empagliflozin and dapagliflozin for heart failure with preserved ejection fraction) and prasugrel was relisted for acute coronary syndrome. One major change occurred on the PHARMAC schedule (empagliflozin for heart failure with reduced ejection fraction). CONCLUSIONS: The 2023-2025 period has seen notable additions to cardiovascular pharmacotherapy in Australia, including the first cardiac myosin inhibitor, the first transthyretin stabiliser, expanded lipid lowering therapy options, and extension of SGLT2 inhibitor coverage across the heart failure ejection fraction spectrum. A pronounced access disparity persists between Australia and New Zealand.

New Zealand

Enhanced fracture detection on radiographs with AI assistance for clinicians: a systematic review and meta-analysis.

BACKGROUND: Emergency radiographic interpretation for fractures is prone to missed or misdiagnoses. Artificial intelligence (AI) is expected to become a powerful tool to assist clinicians in fracture detection. PURPOSE: A systematic review and meta-analysis was performed to assess whether AI improves clinicians' ability to detect fractures on radiographs. MATERIALS AND METHODS: A literature search was conducted in PubMed, Web of Science, and Cochrane Library for studies published between January 1, 2010, and October 10, 2025. A meta-analysis of diagnostic accuracy studies was performed using a Summary Receiver Operating Characteristic (SROC) curve. The quality of included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Subgroup analysis and meta-regression were conducted to explore potential sources of heterogeneity. RESULTS: A total of 26 studies were included . The pooled sensitivity of clinicians increased from 77% (95% CI: 72-81) to 87% (95% CI: 83-90) with AI assistance, while the pooled specificity improved from 88% (95% CI: 85-90) to 92% (95% CI: 89-94). The corresponding AUC values were 0.90 (95% CI: 0.87-0.92) before and 0.95 (95% CI: 0.93-0.97) after AI assistance. Eight studies were rated as high risk of bias. Subgroup analysis and meta-regression identified potential sources of heterogeneity, including fracture location, AI model type, high risk of bias, and reference standards. CONCLUSION: AI assistance significantly improves clinicians' diagnostic performance in detecting fractures on radiographs for extremity and trunk fractures.

Humans

Photon-counting detector computed tomography (PCD-CT) in multiple myeloma: a systematic review and trial sequential meta-analysis on image quality and radiation dose.

OBJECTIVES: To systematically review and perform a meta-analysis comparing the effects of PCD-CT versus EID-CT on image quality (sharpness) and radiation dose (CTDIvol) in patients with bone lesions due to multiple myeloma&#xa0;(MM). METHODS: A comprehensive search of PubMed, Embase, Scopus, and Cochrane Central was conducted from inception to October 2025. Studies comparing PCD-CT and EID-CT in MM patients were included. Methodological quality was assessed using ROBINS-I, and the certainty of evidence was assessed using GRADE. RESULTS: A total of 41 studies were identified that matched our search criteria. After duplicate removal and screening, five studies (n = 170 patients) were included in the systematic review, with four contributing to the meta-analysis. PCD-CT showed a significant pooled mean difference in image sharpness (mean difference, + 0.99 points; 95% CI, 0.62-1.37; p < 0.001). PCD-CT also demonstrated a reduction in radiation dose (mean difference, -4.95 milligrays; 95% CI, -8.39 to -1.50; p = 0.005). Trial sequential analysis (TSA) confirmed stability of pooled estimates, with conclusive evidence for image sharpness improvement, and suggestive yet incomplete evidence for radiation dose reduction. CONCLUSION: Compared to EID-CT in MM, PCD-CT significantly improves subjective image sharpness as supported by trial sequential analysis. Conventional meta-analysis suggested a reduction in radiation dose with PCD-CT; however, trial sequential analysis indicated that the cumulative evidence remains inconclusive. Further large-scale studies are suggested to confirm the magnitude of the radiation dose reduction benefit.

Humans

Non-destructive prediction of lead content in oilseed rape leaves by fluorescence hyperspectral technology based on neural network.

Based on fluorescence hyperspectral imaging (FHSI), this study targeted rapid, non-destructive quantification of lead (Pb) content in oilseed rape leaves treated with varying silicon (Si) concentrations, acquiring fluorescence spectra over the 484.43-1001.61&#xa0;nm wavelength range. To optimize spectral data quality, preprocessing methods (Savitzky-Golay smoothing, first derivative, detrending) were comprehensively compared. Characteristic wavelengths were then selected via interval variable iterative shrinkage, which effectively compressed data dimensionality and reduced computational load. A hybrid SE-CL1DA model, fusing a 1D convolutional neural network, a long short-term memory network and SE attention mechanism was constructed, with Bayesian optimization tuning hyperparameters to boost stability. The BO-SE-CL1DA outperformed both traditional machine learning and insufficiently optimized deep learning model (Rp2=0.9609, RMSE&#xa0;=&#xa0;0.0377&#xa0;mg/kg, RPD&#xa0;=&#xa0;5.1736), thus enabling accurate Pb estimation, supporting Si-regulated heavy metal stress management and facilitating agricultural contamination monitoring.

Plant Leaves

Recovering membrane interaction kinetics of single molecules from 3D tracking data.

Interactions between cytosolic biomolecules and the bacterial inner membrane are fundamental to many cellular processes, yet directly measuring their binding kinetics in living cells remains challenging. Conventional 2D single-molecule tracking analyses can be insufficient, particularly when membrane association does not markedly alter the diffusion rate. Here, we present a method to recover membrane interaction kinetics from 3D single-molecule trajectories in rod-shaped bacteria. Using simulated 3D tracking data, we identify membrane-associated motion by quantifying how well short trajectory segments follow the circular curvature of the cell membrane. The resulting measure is further analyzed using a hidden Markov modeling framework, enabling robust discrimination between cytosolic and membrane-bound states and capturing the dynamics of state transitions without requiring diffusion-rate changes or direct colocalization with membrane markers. This work establishes a general framework for extracting membrane interaction kinetics from 3D single-molecule tracking data in live bacteria and highlights the value of realistic microscopy simulations for quantitative interpretation and systematic bias assessment.

Kinetics

Synaptic vesicle glycoprotein 2A PET imaging in parkinsonian &#x3b1;-synucleinopathies: a systematic review.

Synaptic dysfunction is increasingly recognized as an early and biologically relevant component of &#x3b1;-synucleinopathies. However, conventional imaging biomarkers mainly assess dopaminergic dysfunction, glucose metabolism, or structural damage rather than presynaptic density itself. Synaptic vesicle glycoprotein 2A (SV2A) PET enables in vivo assessment of presynaptic terminal integrity and may provide complementary information in Parkinson's disease (PD), Parkinson's disease dementia/dementia with Lewy bodies (PDD/DLB), and multiple system atrophy (MSA). This systematic review synthesized the available evidence on SV2A-targeted PET in parkinsonian &#x3b1;-synucleinopathies, focusing on regional imaging patterns, clinical associations, longitudinal findings, and methodological determinants of interpretation. Seventeen reports were included. In PD, the most recurrent finding was reduced SV2A binding in the substantia nigra, although additional involvement of brainstem, caudate, striatal, thalamic, raphe, or cortical regions was reported in selected cohorts. In PDD/DLB, abnormalities appeared broader and more cortical, with evidence of association between cortical SV2A binding and cognitive performance. In MSA, one study suggested a distinct infratentorial and cerebellar pattern with potential relevance for phenotypic stratification. SV2A PET is a promising research biomarker for biological characterization of synucleinopathies. However, the field remains limited by small cohorts, methodological heterogeneity, variable quantification strategies, limited longitudinal evidence, and potential cohort overlap. Multicentre validation and harmonized protocols are required before clinical translation.

Humans

Physical Appearance Anxiety and Eating Disorders Symptomatology: A Systematic Review and Meta-Analysis.

The present study aimed to assess the link between physical appearance anxiety (PAA) and eating disorder (ED) symptomatology by a meta-analysis of existing literature. Eligible studies were searched across six electronic databases up until November 20, 2025. Pooled effect sizes (r) were calculated using random-effects models. Potential variables that influence effect heterogeneity were analyzed by univariable and multivariable meta-regressions. Influence analyses and a three-parameter selection model (3PSM) were used to assess robustness of the results and publication bias. Twenty-seven effect sizes from 21 studies (N&#x2009;=&#x2009;5261) were obtained. The results indicated a strong association (i.e., r&#x2009;=&#x2009;0.559) between the two variables under consideration, which was notably stronger (i) among females compared to males; and (ii) for overall eating disorder symptoms rather than bulimic symptoms. The results of this study advocate for further investigation into the effectiveness of addressing anxiety responses related to personal body traits, particularly among females, within the context of preventing and treating eating disorders.

Humans

Intravenous thrombolysis for ischemic stroke in extended time window selected with CT perfusion: a systematic review and meta-analysis.

PURPOSE: Recent randomized controlled trials (RCTs) have provided new evidence regarding the efficacy and safety of intravenous thrombolysis (IVT) in patients with acute ischemic stroke (AIS) presenting within the extended time window (ETW). We performed a systematic review and meta-analysis to evaluate the efficacy and safety of IVT, in patients treated within the ETW and selected with perfusion imaging criteria, predominantly computed tomography perfusion (CTP). METHODS: A systematic review and meta-analysis, registered in PROSPERO, was conducted including all available RCTs comparing IVT with best medical treatment (BMT) in patients with AIS within the ETW, selected using advanced perfusion imaging criteria. The predefined efficacy outcomes were excellent functional outcome and good functional outcome at 3 months. The safety endpoints included symptomatic intracranial hemorrhage (sICH) and all-cause mortality at 90 days. RESULTS: Six RCTs, including 1182 patients treated with IVT and 1176 patients receiving BMT, were included. IVT was associated with a higher likelihood of achieving excellent and good functional outcomes at 3 months. Exploratory subgroup analyses by treatment timing suggested consistent findings up to 24 hours. No significant difference in 90-day mortality was observed between groups, whereas IVT was associated with an increased risk of sICH. CONCLUSION: Treatment with IVT in the ETW (4.5-24 h) in patients selected using advanced perfusion imaging, predominantly CTP, may be associated with improved functional outcomes in patients with AIS. Although IVT was associated with an increased risk of sICH, no significant increase in 90-day mortality was observed. PROSPERO REGISTRATION: CRD420261304314.

Aged

Shielding performance and clinical applicability of lead-free materials in computed tomography.

Owing to the high radiation exposure associated with computed tomography (CT) examinations and the image quality degradation caused by conventional radiation shielding materials, this study evaluated the dose reduction performance and image quality maintenance potential of a newly developed lead-free composite shielding material. This material was composed of bismuth, tungsten, tungsten carbide, aluminium, and polyurethane. Phantom-based dose measurements demonstrated that the shielding material achieved dose reduction rates ranging from 17.6% to 37.6%, depending on tube voltage. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and changes in tube current-time product (mAs) under a scout-based automatic exposure control (AEC) protocol were analysed according to the presence or absence of the shielding material across regions. For the clinical evaluation, CT scans were performed on four patients. Furthermore, the images were reviewed to evaluate whether this material affected image quality. The shielding material exhibited radiation reduction levels comparable to those reported in previous studies. SNR and CNR analyses showed minor statistical variations in certain regions; however, most differences were not statistically significant, and even significant differences remained within a range that did not compromise diagnostic image quality. Under the scout-based AEC protocol, the use of the shielding material resulted in less than 1% variation in mAs values. No visually perceptible artefacts or clinically significant image quality degradation were observed. The proposed composite shielding material demonstrated the potential to mitigate some limitations of conventional shielding materials and showed preliminary clinical feasibility as an adjunctive strategy for radiation dose reduction in CT examinations.

Radiation Protection

Effects of Sacubitril Valsartan Combined With Vericiguat on NT-proBNP and CK-MB Levels in Patients With Chronic Heart Failure.

This study aims to probe the influence of sacubitril valsartan sodium tablets combined with vericiguat on N-terminal pro-B-type natriuretic peptide (NT-proBNP) and creatine kinase isoenzyme (CK-MB) levels in patients with chronic heart failure (CHF). One hundred and twenty CHF patients were enrolled and stratified into a control group (sacubitril valsartan sodium tablets) and a combination group (sacubitril valsartan sodium tablets&#x2009;+&#x2009;vericiguat). Outcome measures included New York Heart Association (NYHA) functional class shifts, echocardiographic indices, cardiac injury markers, 6-min walk distance (6MWD), endothelial function parameters, inflammatory mediator levels, and adverse clinical events. Following a 6-month treatment period, patients in the combination group exhibited superior functional improvement, as reflected by greater advancement in NYHA class. Echocardiographic evaluation revealed more favorable ventricular remodeling in this group, with reduced left ventricular end-diastolic and end-systolic diameters and an elevated ejection fraction. The combination group had a higher 6MWD. Biomarker analysis showed lower NT-proBNP and CK-MB levels in the combination group. Furthermore, improvements in endothelial function were noted, with decreased endothelin and elevated NO, NOS, and CGRP levels in the combination group. Markers of systemic inflammation, including CRP and IL-6, were also attenuated in the combination group. The incidence of adverse reactions and cardiovascular events did not differ significantly between the groups. Co-administration of sacubitril/valsartan and vericiguat enhances cardiac performance, optimizes vascular endothelial responsiveness, modulates heart failure-related biomarkers, and mitigates inflammatory activity in patients with CHF without increasing the risk of adverse events.

Humans

Linked-color imaging with computer-aided detection and the proximal adenoma miss rate: a randomized tandem trial.

BACKGROUND AND AIMS: Linked-color imaging (LCI) aids the detection and characterization of lesions. Computer-aided detection (CADe) systems have been introduced to improve lesion detection during colonoscopy. Although several studies have been reported regarding LCI, few have investigated the combination of LCI and CADe. This study aimed to evaluate the efficacy of LCI with CADe colonoscopy compared to conventional white-light colonoscopy. METHODS: A single-center, randomized tandem trial was conducted. Participants referred for first-time colonoscopy after fecal immunochemical test (FIT)-positive, asymptomatic screening, or surveillance colonoscopy were randomized (1:1) to undergo CADe-assisted colonoscopy of LCI or white-light imaging (WLI) in the right side of the colon. The primary outcome was adenoma miss rate (AMR) in the right side of the colon. Secondary outcomes included polyp miss rate (PMR), diminutive adenoma miss rate (dAMR), sessile serrated lesion miss rate (SSLMR), advanced adenoma miss rate, advanced neoplasia miss rate, flat-type lesion miss rate (FMR), and the differences in miss rates based on expertise. RESULTS: Among 232 randomized participants, 209 were analyzed (LCI/CADe: 102; WLI: 107). AMR (WLI: 39% vs LCI/CADe: 20%; P = .001), PMR (42% vs 18%; P < .001), and dAMR (42% vs 21%; P = .003) were significantly lower in the LCI/CADe arm, particularly among experts. SSLMR (46% vs 0%), advanced AMR (30% vs 0%), advanced neoplasia miss rate (25% vs 0%), and FMR (27% vs 5.6%) were lower in LCI/CADe, although without statistical significance. CONCLUSIONS: Compared to conventional colonoscopy, LCI with CADe colonoscopy resulted in a statistically significant decrease, especially in AMR. (UMIN 000050685).

Humans

An RPA-assisted homogeneous electrochemical DNA sensor for on-site eDNA detection toward early warning of crown-of-thorns starfish outbreaks.

Crown-of-thorns starfish (COTS) outbreaks seriously threaten coral reef ecosystems, while conventional monitoring approaches are time-consuming and often lack sufficient sensitivity for early warning. Existing electrochemical DNA sensors usually require complex electrode-surface immobilization procedures, which can lead to uneven probe distribution, significant steric hindrance, and poor stability. Meanwhile, the low concentration of environmental DNA (eDNA) in marine environments further complicates detection. To overcome these challenges, this study developed a homogeneous electrochemical DNA sensor assisted by recombinase polymerase amplification (RPA) for COTS eDNA detection. Target DNA was first amplified by RPA, and the amplification products were then hybridized in solution with capture probe (CP)-modified magnetic beads (MB) and biotin-labeled signal probe (SP) to form sandwich-structured MB complexes. These complexes were subsequently magnetically enriched and immobilized on the electrode surface for electrochemical signal readout. Under optimized conditions, the sensor displayed a linear response to COTS genomic DNA from 3.77&#xa0;fg/&#x3bc;L to 1&#xa0;ng/&#x3bc;L, with an LOD of 2.02&#xa0;fg/&#x3bc;L and an LOQ of 3.77&#xa0;fg/&#x3bc;L. The sensor was applied to Xisha Islands samples, and the results agreed with droplet digital PCR (ddPCR) (P&#xa0;>&#xa0;0.05), demonstrating its potential for sensitive and reliable on-site COTS eDNA detection.

Animals

Initial 4-Year Experience With Microaxial Flow Pumps Within a Tertiary Centre in Regional Australia.

BACKGROUND & AIM: The Microaxial Flow Pump (MFP) is a miniaturised rotary pump that aspirates blood from the left ventricle and expels it into the ascending aorta. It unloads the left ventricle and increases mean arterial pressure and cardiac output. MFP is most commonly utilised in cardiogenic shock, for protected percutaneous coronary intervention (PCI), and for ventricular offloading in veno-arterial extracorporeal membrane oxygenation (VA-ECMO). METHOD: We conducted a retrospective review of all patients who underwent MFP insertion at John Hunter Hospital, Australia. Categorical data are represented as counts and percentages, with continuous variables described as means with standard deviations. RESULTS: Twenty-three MFP devices were inserted between September 2020 and May 2024. Five (22%) were for protected PCI, three (13%) for venting with VA-ECMO (ECPELLA), and 15 (65%) for acute coronary syndrome (ACS) and cardiogenic shock. The median age for the overall cohort was 62 years, with a 74% male predominance. Eighty percent of the protected PCI cohort were elective outpatient procedures, and there were no deaths in this cohort. The mortality in the ECPELLA group was 67%. Thirteen (87%) of the patients with cardiogenic shock presented with an anterior infarct, and 53% had cardiac arrest on admission. The overall morality in the cardiogenic shock cohort was 40%. Complications in this cohort included limb ischaemia in four patients (17%) and site bleeding in seven patients (30%). Four patients (17%) required vascular surgery intervention. CONCLUSION: Our initial experience showed the use of MFP in a tertiary centre was safe and feasible, allowing progression from protected percutaneous intervention to acute cardiogenic shock.

Humans

Ketamine Plus Midazolam versus Fentanyl Plus Midazolam for Sedation and Analgesia during Image-guided Procedures in Interventional Radiology: Randomized Clinical Trial.

Background Opioid-benzodiazepine regimens remain common for radiologist-administered procedural sedation despite respiratory and analgesic effectiveness concerns. Purpose To compare intraprocedural pain and patient-reported experience between ketamine/midazolam and fentanyl/midazolam during image-guided procedural sedation. Materials and Methods This randomized clinical trial was conducted at a single academic center between June 2025 and February 2026. Adults undergoing image-guided lung or bone biopsy or abscess drainage were randomized to fentanyl/midazolam or ketamine/midazolam administered by interventional radiologists. Procedures were performed using US, CT, CT fluoroscopy, or combined CT and US guidance. The primary outcome was maximum intraprocedural pain (0-10 on the Numeric Rating Scale). Secondary outcomes included sedation depth, physiologic parameters, oxygen desaturation, patient-reported experience assessed using a modified Heidelberg questionnaire, and complications. Results Among 264 randomized procedures (132 procedures per group) in 260 participants (median age, 68 years [IQR, 61-75 years]; 135 [52%] female), ketamine/midazolam resulted in lower maximum intraprocedural pain than fentanyl/midazolam (mean difference, -1.4 points [95% CI: -2.0, -0.8]; P < .001). Pain scores greater than 4 occurred less frequently with ketamine/midazolam (2.3% vs 17%; absolute difference, 14 percentage points [95% CI: 8, 21]; P < .001). Ketamine/midazolam was associated with higher nadir oxygen saturation (mean difference, +1.4% [95% CI: 0.6, 2.2]; P = .001) and fewer oxygen desaturation events below 90% (three [2.3%] vs 13 [9.8%]; absolute difference, 7.6 percentage points [95% CI: 1.9, 13.3]; P = .02). Ketamine/midazolam produced deeper sedation and higher intraprocedural systolic blood pressure. Hallucinations occurred more frequently with ketamine/midazolam (15 [11.4%] vs five [3.8%]; absolute difference, 7.6 percentage points [95% CI: 1.3, 13.9]; P = .03), though overall procedural comfort, reduced recall, and perceived adequacy of sedation were improved. Procedure-related and sedation-related complications did not differ between groups. Conclusion Radiologist-administered ketamine/midazolam during image-guided procedural sedation improved analgesia and patient-reported experience with fewer hypoxemic events and no increase in complications compared with fentanyl/midazolam. Clinical trial registration no. NCT07040163

Aged

Gender-specific pathways linking body dissatisfaction, self-disgust, and social anxiety in Chinese adolescents: A three-wave longitudinal study.

Adolescence is a critical period for physical and psychological development. Body dissatisfaction is a significant concern during this stage, contributing to psychological issues such as social anxiety. However, the longitudinal relationships among body dissatisfaction, self-disgust, and social anxiety, as well as the potential role of gender differences in these dynamics, remain unclear. A total of 1109 junior high school students in China completed the baseline survey, with data collected at three time points (Mage = 12.67 years, SD&#x202f;=&#x202f;0.68; 51.9% girls). Data were collected using the Body Areas Satisfaction Scale (BASS), the Self-Disgust Scale (SDS), and the Social Anxiety Scale for Children (SASC). Structural equation modeling (SEM) was employed to examine the longitudinal mediating effects among body dissatisfaction, self-disgust, and social anxiety, as well as to explore gender differences in these relationships. After controlling for autoregressive effects of self-disgust and social anxiety across waves, body dissatisfaction at T1 was found to indirectly predict social anxiety at T3 through self-disgust at T2, while indirectly predicting self-disgust at T3 through social anxiety at T2. Multi-group analyses revealed significant gender differences: for females, only the mediating pathway with self-disgust as the mediator was significant; for males, only the pathway with social anxiety as the mediator was significant. These findings contribute to a more nuanced understanding of the emotional mechanisms linking body dissatisfaction to social anxiety and highlight the importance of considering gender-specific pathways in prevention and intervention efforts.

Adolescent

Comparison of Iodinated Contrast Doses Based on Total Body Weight and Lean Body Weight in Pediatric Patients: Impact on Image Quality and Contrast Exposure.

INTRODUCTION: Iodinated contrast dosing in pediatric computed tomography (CT) traditionally relies on total body weight (TBW), which may result in excessive contrast administration, particularly in patients with higher adiposity. Lean body weight (LBW)-based protocols have shown promise in adults but remain underexplored in children. Therefore, the aim of this study was to compare contrast volume requirements and hepatic enhancement quality among three dosing protocols: LBW-based, TBW-based, and the Control Group (CG), based on the institutional standard for pediatric abdominal CT. METHODS: This prospective study enrolled 66 patients (age 0-16 years) undergoing contrast-enhanced abdominal CT between September 2023 and August 2024. Patients were randomly assigned to receive iodinated contrast (iobitridol 350mg I/mL) dosed by: (1) LBW (0.63 g iodine/kg x LBW, calculated using Peters formula; n = 23), (2) TBW (0.46 g iodine/kg x TBW; n = 20), or (3) institutional control protocol (2 mL/kg x TBW, equivalent to 0.7 g iodine/kg; n = 23). Kruskal-Wallis, ANOVA, Two-way ANOVA, ANCOVA, Scheirer-Ray-Hare, and Cohen's Kappa tests with Likert scale were used. RESULTS: The LBW group received lower median contrast volumes (27 mL; IQR, 10-80 mL) compared to the TBW group (34.5 mL; IQR, 18-78 mL) and the CG group (40 mL; IQR, 13-80 mL), although the differences did not reach statistical significance (P > 0.05). Notably, this reduction did not compromise hepatic enhancement, which remained comparable to the CG (552 &#xb1; 139 HU; P = 0.107). CONCLUSION: Lean body weight may be a useful parameter for estimating contrast dose in pediatric abdominal CT, potentially reducing administered volumes without compromising diagnostic image quality. IMPLICATIONS FOR PRACTICE: These results provide early evidence that LBW-based dosing may support more individualized contrast administration in pediatric CT, potentially reducing exposure-related risks.

Humans

Liquid biopsy-based detection of circulating and exfoliated cholangiocarcinoma tumor cells from blood and bile using heparan sulfate octasaccharides on integrated microfluidic systems.

Early diagnosis of cholangiocarcinoma (CCA) remains challenging because existing diagnostic approaches often lack sufficient sensitivity for reliable detection of early-stage disease. Circulating tumor cells (CTCs) in blood and exfoliated tumor cells (ETCs) in bile represent valuable targets for liquid biopsy-based detection; however, their low abundance and the complexity of clinical sample analysis pose substantial technical challenges for reliable enrichment and identification. Herein, we present a reproducible workflow for isolating and identifying CCA tumor cells from blood for CTCs and bile for ETCs using synthetic cell-surface heparan sulfate (HS) octasaccharide-functionalized magnetic beads (MBs) on integrated microfluidic systems. The method combined sample pre-processing, magnetic bead-based enrichment, controlled low-shear mixing and immunofluorescence-based identification into a unified workflow compatible with distinct clinical sample types. Key operational parameters, including MB concentration, mixing frequency, and pressure settings, were detailed to facilitate consistent performance. Using this workflow, tumor cell capture rates of approximately 70% in bile (for ETCs) and blood (for CTCs) were achieved, with a total processing time of 60-90&#xa0;min per sample under clinically relevant low-abundance conditions. The platform enables reliable detection of as few as 1 tumor cell per mL of blood or bile. This method provides a practical and adaptable strategy for glycosaminoglycan-mediated liquid biopsy applications and may be extended to other tumor-cell enrichment workflows involving heterogeneous cell-surface interactions.

Humans