Search PubMedSearch

SEARCH · Search PubMed

Results for “Minimal detectable change”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

734 records · Page 5Linked to original sources

Interfacial engineering of cobalt tungstate-halloysite nanotube nanocomposite for electrochemical detection of synthetic vanillin in food matrices.

In processed foods and medicine, synthetic vanillin is widely used, although excessive intake poses toxicological risks. Due to the rising usage of synthetic vanillin in food products and associated health hazards, quick, sensitive, and reliable analytical methods are needed to precisely measure vanillin in complex food matrices. This work introduces a CoWO4@F-HNT/GCE nanocomposite as an efficient electrocatalytic modifier for glassy carbon electrodes aimed at trace-level synthetic vanillin detection. Structural and microscopic analyses confirmed phase-pure monoclinic CoWO4, preservation of the tubular aluminosilicate framework, and homogeneous nanoparticle anchoring on F-HNT. Differential pulse voltammetry provided a broad linear range from 0.01 to 372.14 μM and a low detection limit of 4.3 nM, together with excellent selectivity against common interferents, good cycling stability, and high inter-electrode reproducibility. These characteristics position the CoWO4@F-HNT-modified electrode as a cost-effective and reliable platform for on-site quality control of synthetic vanillin in complex food matrices.

Benzaldehydes

Influence of soil types with different soil-forming process on the qualitative and quantitative detection of microplastics by near-infrared spectroscopy.

Microplastics (MPs) have become a pressing global environmental threat, with soils-acting as sinks for MPs from multiple sources-gaining increasing attention. Near-infrared (NIR) spectroscopy offers a promising tool for MPs detection due to its rapid, non-destructive, and field-applicable features. Although previous studies have focused on the effects of individual soil components on the NIR detection performance of MPs, there is still a lack of systematic research on how the complex background-formed by the coupling of multiple physicochemical properties in natural soils-affects detection performance. This study focuses on soil types with different soil-forming processes, selected five representative agricultural soils to systematically evaluate how the combinations of physicochemical properties they represented affect the performance of NIR-based qualitative and quantitative analysis of MPs in soils. The results demonstrated that soil type significantly affected both the spectral response and detection performance of MPs. Brown Pedocals and Brown Earth exhibited clearer characteristic absorption and stronger linear responses, achieving higher identification accuracy under low (<1.5 %) or zero MPs concentrations and the best quantitative performance (R2 &#x2265; 0.988, prediction set root mean square error (RMSEP) &#x2264; 0.110 %). In contrast, Phaeozem and Red Soil were more prone to misclassification at low concentrations, while Fluvo-aquic Soil showed the poorest quantitative performance. This study is the first to reveal, at a holistic level, the critical constraints posed by natural soil complexity on the NIR detection of MPs, offering targeted empirical evidence to support the application of NIR technology in real-world soil environments.

Soil

Portable metagenomics for preventive surveillance and outbreak control in livestock and poultry: Pathogen detection, resistome profiling, and antimicrobial stewardship.

Conventional diagnostics for livestock and poultry outbreaks commonly rely on culture or targeted PCR panels, which may be too slow or too narrow to guide early control decisions. Portable metagenomics, particularly real-time nanopore sequencing, offers a route to broad pathogen detection, antimicrobial-resistance gene profiling, and outbreak investigation within an integrated workflow. This implementation-focused review evaluates how near-point-of-care metagenomics may support preventive veterinary medicine through earlier detection, surveillance, cohorting, biosecurity decisions, and antimicrobial stewardship. We synthesize sample-to-answer workflows for enteric and respiratory disease in food-producing animals, including sampling, nucleic-acid extraction, host depletion or target enrichment, library preparation, sequencing, bioinformatics, quality control, and interpretation. Applications in calf diarrhea, bovine respiratory disease, poultry outbreaks, mastitis, and resistome monitoring are considered alongside the central limitation that detection alone does not establish causation. Pathogen and resistance-gene signals must therefore be interpreted with clinical signs, lesions, epidemiology, controls, and confirmatory testing. We also propose a minimum reporting checklist, intended as a practical framework rather than a validated consensus standard. Portable metagenomics is not a replacement for conventional diagnostics, but appropriately validated workflows can reduce uncertainty during time-sensitive outbreaks and support more judicious antimicrobial use.

Animals

Recent advances in electrode materials for electrochemical detection of zearalenone.

Zearalenone (ZEN) is an estrogenic mycotoxin commonly found in cereals, animal feed, and processed foods, making it an important concern for food safety and public health. Conventional chromatographic and immunological methods can detect ZEN; however, they often require expensive instruments, lengthy sample preparation, and skilled personnel, which restrict their use for rapid and on-site testing. Electrochemical sensors have attracted enormous interest of the scientific community because of their high sensitivity, rapid response, low cost, miniaturization potential, and compatibility with portable systems. The analytical performance of the electrochemical sensors is strongly influenced by electrode materials, morphology, conductivity, porosity, surface functionality, and the efficiency of bioreceptor immobilization. Despite several reviews on mycotoxin detection, a systematic assessment connecting electrode-material design, modification strategies, sensing mechanisms, and electroanalytical performance specifically for ZEN sensing remain limited. This review critically evaluates recent advances in metal oxides, carbon-based materials, metal-organic- and covalent organic frameworks, MXenes, polymers, and hybrid composites for electrochemical ZEN detection. Particular attention has been given to their roles in electron transfer, analyte enrichment, selectivity, and real-sample analysis. The review also compares the major limitations of current sensing systems, including complex fabrication, matrix interference, insufficient long-term stability, poor inter-electrode reproducibility, and limited scalability. Finally, future directions for developing robust, cost-effective, portable, and commercially viable ZEN sensors are discussed.

Journal Article

Selective and sensitive colorimetric sensing of carbosulfan based on BiO2-x/Bi2O2.75 nanosheets with excellent haloperoxidase-like activity.

The development of colorimetric methods based on directly inhibiting nanozyme activity for pesticide detection has attracted considerable attention. In this study, we report a novel colorimetric sensing strategy utilizing BiO2-x/Bi2O2.75 nanosheets (BiO2-x/Bi2O2.75 NSs) with haloperoxidase (HPO)-like activity for the rapid and sensitive detection of carbosulfan (CBS) in foods. Oxygen-vacancy-rich BiO2-x/Bi2O2.75 NSs with HPO-like activity were rationally constructed. Kinetic studies revealed a remarkable Michaelis-Menten constant (Km) of 0.014&#xa0;mM for I-, indicating a higher affinity for iodide ions than other reported HPO-like nanozymes, as evidenced by its lower Km. Under acidic conditions, CBS tends to be hydrolyzed to produce reductive sulfide species, which directly inhibit the iodoperoxidase-like activity of BiO2-x/Bi2O2.75 NSs, enabling selective detection with a limit of detection (LOD) of 0.18&#xa0;&#x3bc;g/mL and a linear range of 0.20-100&#xa0;&#x3bc;g/mL. When the concentration of interfering pesticides and substances was 5 times that of CBS, the sensor remained unaffected, exhibiting excellent stability and specificity. This work contributes to the detection of CBS in complex food matrices, bridging the application gap of HPO-like nanozymes in pesticide detection and providing a promising method for food safety detection.

Colorimetry

A point-of-use SERS assay for rapid detecting difenoconazole and flusilazole residues in fruit juices using Au/COF substrate.

We developed a ready-to-use surface-enhanced Raman scattering (SERS) sensor for rapid, pretreatment-free detection of difenoconazole (DIF) and flusilazole (FLU) in peach and lychee juices. The substrate combines Au nanoparticles (AuNPs) with covalent organic frameworks (COF) and is implemented on a portable 25-well plate, enabling in situ testing. Juices can be directly applied to the SERS-active Au/COF composite, allowing simultaneous adsorption and signal generation. The correlation between SERS intensity and logarithmic concentration yielded R-values between 0.925 and 0.986, meeting the monitoring needs of non-laboratory scenarios. The entire workflow completes within 12&#xa0;min, offering a faster alternative to conventional methods while maintaining high sensitivity and reproducibility. Detection limits reach 0.96-1.22&#xa0;ppb for DIF and FLU, both of which are below the regulatory maximum residue limits. Distinct SERS fingerprints enable reliable discrimination of mixed residues across juice matrices, supporting rapid on-site monitoring and cost-effective pesticide surveillance.

Triazoles

A homogeneous immunoassay based on AlphaLICA technology for detecting florfenicol residues in animal-derived foods.

Florfenicol (FF), a broad-spectrum amide antibiotic widely used in livestock, poultry, and aquaculture, poses potential threats to food safety and public health due to its residual accumulation. In this study, a novel homogeneous immunoassay based on Amplified Luminescent Proximity Homogeneous Assay (AlphaLICA) technology was developed for the first time for rapid screening of FF residues in milk and egg matrices. By covalently immobilizing the FF-BSA conjugate and goat anti-mouse IgG onto luminescent and photosensitive microspheres, respectively, the method achieved wash-free, homogeneous quantitative detection through a competitive immunoreaction. Under optimized conditions, the assay exhibited a linear range of 0.2-16.2 ng mL-1, with a limit of detection of 9.7 pg mL-1 and a limit of quantification of 183 pg mL-1. The intra- and inter-batch coefficients of variation ranged from 3.08% to 5.70% and 2.44% to 7.09%, respectively. Spike recovery rates in milk and egg matrices ranged from 93.18% to 107.17% (RSD &#x2264; 5.57%). Cross-reactivity with 11 other common antibiotics, including chloramphenicol and thiamphenicol, was below 0.1%, demonstrating excellent specificity. Comparative analysis with a commercial ELISA kit showed high consistency (r2 = 0.9332, p < 0.001). With high sensitivity, strong specificity, simple operation, and a detection time of only 10 min, this method provides a reliable technical platform for high-throughput, rapid monitoring of FF residues in milk and egg matrices.

Journal Article

Emergence of a Novel, Phenotypically Difficult-to-Detect Vancomycin-Resistant Enterococcus faecium Clone (ST117/CT7799).

A significant increase of vancomycin-resistant Enterococcus faecium (VREfm) infections was observed in South-Eastern Austria since 2024. The prolonged outbreak is caused by a novel vanB-VREfm clone (ST117/CT7799, "VREfmstyr"). This study characterizes the atypical difficult-to-detect resistance phenotype and assesses the genomic relatedness of the isolates. Patient and outbreak characteristics were investigated including whole genome sequencing of the isolates. Sensitivity of broth microdilution (BMD), gradient tests (GT), disk diffusion (DD), and automated susceptibility testing (VITEK2) was compared. The performance of commercial screening media was evaluated. From sporadic detections in early 2024 case numbers began to rise during the year. In 30/31 (97%) of all cases, intra-hospital transmission was considered likely and an association with invasive procedures was identified in most cases. Core genome multilocus sequence typing revealed only six allelic differences between VREfmstyr isolates collected in a 12-month period, all belonging to the E. faecium ST117/CT7799 lineage. BMD detected vancomycin resistance (MIC&#x2009;>&#x2009;4&#x2009;mg/L) in no more than 16/31 (52%) of isolates after 24&#x2009;h incubation, while GT and DD misclassified all isolates. Only prolonged incubation improved the performance of these assays. VITEK2 analysis, however, correctly classified all 31 isolates. Of four commercially available VRE-screening agars, only one was capable of detecting VREfmstyr after 24&#x2009;h incubation. The emergence and clonal dissemination of VREfm ST117/CT7799 reveals a serious diagnostic gap as commonly used diagnostic algorithms fail to reliably detect this resistance phenotype. Our findings should help to further evaluate the true geographical distribution and clinical significance of this novel VREfm clone.

Enterococcus faecium

Genomic and One Health insights into Vibrio parahaemolyticus from environmental, seafood and clinical sources.

Vibrio parahaemolyticus is a leading cause of seafood-borne gastroenteritis worldwide, with climate warming facilitating its spread to high-latitude areas. In this study, we analyzed 212 genomes of environmental and seafood-associated isolates collected from seven cities in Zhejiang Province, China (2019-2024), alongside 228 clinical genomes from public databases. The 212 isolates were assigned to 172 sequence types (STs), with ST490 being the most frequent (5/212, 2.36%). Forty-four serotypes were identified, dominated by OL3:KUT (12.68%). High ST and serotype diversity were observed across different sample types and sources, with median pairwise single nucleotide polymorphisms (SNPs) ranging from 57,431 to 58,378, indicating comparable genetic diversity across groups. All isolates carried tlh and T3SS1 but lacked tdh and T3SS2. Resistance rates against ampicillin and cefazolin were 54.72% (116/212) and 44.34% (94/212), respectively, with multidrug resistance (MDR) detected in nine isolates, predominantly from seafood (7/9). A total of 63 distinct antimicrobial resistance genes (ARGs) spanning seven classes were identified. Isolates from aquaculture farms and wet markets exhibited greater resistance category diversity and higher ARG carriage than those from coastal or riverine sites. In contrast, the 228 clinical isolates harbored only 25 ARGs across two classes, with a significantly lower proportion of isolates carrying multiple ARG classes (0.44% vs. 6.13%, P&#xa0;<&#xa0;0.001). Human isolates formed tighter phylogenetic clusters, although a minority were closely related to environmental/foodborne strains. Overall, our findings demonstrate the genetic diversity and resistance potential of V. parahaemolyticus across environmental, seafood, and clinical sources, highlighting the importance of the One Health approach to comprehensive public health risk assessment.

Vibrio parahaemolyticus

A versatile reversed-phase liquid chromatography charged aerosol detection method for streamlined monitoring of QS-21 content and stability in liposomal adjuvant formulations.

Identifying and quantifying an active adjuvant along with its degradants in drug formulations is essential for ensuring the safety and efficacy of the drug product. QS-21 is a potent adjuvant that is being evaluated in several clinical trials and is currently formulated in licensed vaccines that protect against shingles, malaria, and RSV. In aqueous environments, QS-21 is subject to hydrolytic degradation that is influenced by pH and temperature, resulting in the formation of a degradant known as QS-21 Hydrolyzed Product, QS-21 HP, which can occur during manufacturing and/or prolonged storage. The intact QS-21 and QS-21 HP induce distinct immune response profiles, making it critical to monitor the degradation of QS-21 in vaccine adjuvant formulations. To date, there has been a paucity of reliable assays for QS-21, its isomers, and degradant QS-21 HP in liposomal adjuvant formulations available that can be transferred seamlessly in quality control (QC) environments. Herein, we introduce a simple and QC-friendly liquid chromatography coupled to a charged aerosol detector (LC-CAD) enabled by stationary phase screening combined with in silico method development optimization. The method exploits 2.7&#xa0;&#x3bc;m fused-core phenyl hexyl particles, ensuring its versatility in standard and ultra-high pressure LC systems. This approach demonstrates a high correlation between predicted retention time (RT) and experimental outcomes with overall &#x2206;RT&#xa0;<&#xa0;4%. In addition, this assay shows great linearity, precision, specificity, and accuracy to advance process development characterization of new vaccine formulations.

Liposomes

Enhanced fracture detection on radiographs with AI assistance for clinicians: a systematic review and meta-analysis.

BACKGROUND: Emergency radiographic interpretation for fractures is prone to missed or misdiagnoses. Artificial intelligence (AI) is expected to become a powerful tool to assist clinicians in fracture detection. PURPOSE: A systematic review and meta-analysis was performed to assess whether AI improves clinicians' ability to detect fractures on radiographs. MATERIALS AND METHODS: A literature search was conducted in PubMed, Web of Science, and Cochrane Library for studies published between January 1, 2010, and October 10, 2025. A meta-analysis of diagnostic accuracy studies was performed using a Summary Receiver Operating Characteristic (SROC) curve. The quality of included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Subgroup analysis and meta-regression were conducted to explore potential sources of heterogeneity. RESULTS: A total of 26 studies were included . The pooled sensitivity of clinicians increased from 77% (95% CI: 72-81) to 87% (95% CI: 83-90) with AI assistance, while the pooled specificity improved from 88% (95% CI: 85-90) to 92% (95% CI: 89-94). The corresponding AUC values were 0.90 (95% CI: 0.87-0.92) before and 0.95 (95% CI: 0.93-0.97) after AI assistance. Eight studies were rated as high risk of bias. Subgroup analysis and meta-regression identified potential sources of heterogeneity, including fracture location, AI model type, high risk of bias, and reference standards. CONCLUSION: AI assistance significantly improves clinicians' diagnostic performance in detecting fractures on radiographs for extremity and trunk fractures.

Humans

Linked-color imaging with computer-aided detection and the proximal adenoma miss rate: a randomized tandem trial.

BACKGROUND AND AIMS: Linked-color imaging (LCI) aids the detection and characterization of lesions. Computer-aided detection (CADe) systems have been introduced to improve lesion detection during colonoscopy. Although several studies have been reported regarding LCI, few have investigated the combination of LCI and CADe. This study aimed to evaluate the efficacy of LCI with CADe colonoscopy compared to conventional white-light colonoscopy. METHODS: A single-center, randomized tandem trial was conducted. Participants referred for first-time colonoscopy after fecal immunochemical test (FIT)-positive, asymptomatic screening, or surveillance colonoscopy were randomized (1:1) to undergo CADe-assisted colonoscopy of LCI or white-light imaging (WLI) in the right side of the colon. The primary outcome was adenoma miss rate (AMR) in the right side of the colon. Secondary outcomes included polyp miss rate (PMR), diminutive adenoma miss rate (dAMR), sessile serrated lesion miss rate (SSLMR), advanced adenoma miss rate, advanced neoplasia miss rate, flat-type lesion miss rate (FMR), and the differences in miss rates based on expertise. RESULTS: Among 232 randomized participants, 209 were analyzed (LCI/CADe: 102; WLI: 107). AMR (WLI: 39% vs LCI/CADe: 20%; P = .001), PMR (42% vs 18%; P < .001), and dAMR (42% vs 21%; P = .003) were significantly lower in the LCI/CADe arm, particularly among experts. SSLMR (46% vs 0%), advanced AMR (30% vs 0%), advanced neoplasia miss rate (25% vs 0%), and FMR (27% vs 5.6%) were lower in LCI/CADe, although without statistical significance. CONCLUSIONS: Compared to conventional colonoscopy, LCI with CADe colonoscopy resulted in a statistically significant decrease, especially in AMR. (UMIN 000050685).

Humans

Artificial intelligence for dental caries detection: An umbrella review.

Artificial intelligence (AI) has been proposed as a tool to improve dental caries detection across imaging modalities; however, its clinical value remains uncertain. This umbrella review aimed to synthesize and critically appraise systematic reviews evaluating AI for caries detection and diagnosis. An umbrella review was conducted following PRIOR guidance (PROSPERO CRD420261340728). Searches were performed in MEDLINE, Embase, Scopus, Web of Science, and Google Scholar up to 15 March 2026. Methodological quality was assessed using AMSTAR 2, and overlap of primary studies was quantified using the corrected covered area (CCA). Seventeen systematic reviews were included, of which five reported diagnostic test accuracy meta-analyses using bivariate or HSROC models. Across these meta-analyses, pooled sensitivity ranged from 0.76 to 0.94 and specificity from 0.85 to 0.91. Most systems were based on deep learning models applied to bitewing radiographs and intraoral photographs. However, substantial heterogeneity was observed in imaging modalities, lesion thresholds, analytical tasks, and evaluation metrics. In addition, a high degree of overlap across reviews and recurrent methodological limitations, including reliance on retrospective datasets, limited external validation, and inconsistent reporting, substantially weaken the reliability of the evidence. Although AI models demonstrate high diagnostic performance under experimental conditions, current evidence does not support their use as stand-alone diagnostic tools. Their clinical applicability remains limited, and implementation should be restricted to decision-support contexts until robust prospective validation demonstrates meaningful impact on clinical decision-making and patient outcomes.

Dental Caries

Metal-organic frameworks nanozyme-integrated portable microneedle patch for visual bacterial monitoring in meat.

Foodborne microbial contamination is a major global health concern, with conventional methods often being time-consuming and complex. Herein, we developed a novel portable biosensor by integrating microneedle patch technology and a metal-organic framework (Fe/Cu-NBDC MOF) nanozyme, enabling rapid, on-site, visual detection of bacteria in meat. The sensing system works by encapsulating aptamer-functionalized MOF nanozymes within a hydrogel patch, where their catalytic sites are initially blocked by the aptamer. In the presence of Staphylococcus aureus (S. aureus) as the target, the specific aptamer's binding to bacteria exposes numerous catalytic sites, further activating the chromogenic reaction of the tetramethylbenzidine&#x2011;hydrogen peroxide (TMB-H&#x2082;O&#x2082;) system, enabling visual detection of S. aureus. The biosensor demonstrates a detection limit of 82&#xa0;CFU/mL with excellent specificity to successfully apply to commercial mutton. By integrating sampling, enrichment, and visual detection into a single compact device, this platform offers a practical, efficient solution for rapid on-site screening of foodborne pathogens.

Biosensing Techniques

Artificial intelligence-assisted detection and optical differentiation of colorectal lesions in Lynch syndrome surveillance (CADLY2): a multicentre, open-label, randomised controlled superiority trial.

BACKGROUND: Artificial intelligence (AI)-based computer-aided detection (CADe) systems improve adenoma detection in average-risk colorectal cancer screening. Meanwhile, evidence in Lynch syndrome surveillance is sparse and inconsistent. We assessed the effect of CADe on adenoma detection during Lynch syndrome surveillance. Computer-aided optical diagnosis (CADx) performance for optical differentiation of colorectal lesions was evaluated as a secondary aim. METHODS: CADLY2 was an international, multicentre, open-label, randomised controlled superiority trial at nine specialised hereditary cancer surveillance centres in Belgium, Germany, the Netherlands, and Spain. Adults aged 18 years or older with genetically confirmed Lynch syndrome scheduled for surveillance colonoscopy were randomly assigned (1:1) to high-definition white-light (HD-WL) colonoscopy alone or to HD-WL colonoscopy with computer-aided assistance from CAD EYE (Fujifilm, Tokyo, Japan). CAD EYE was used for CADe during withdrawal and for CADx after lesion detection. Randomisation was done centrally through a secure web-based system using Pocock's minimisation algorithm with a stochastic component and was stratified by centre, sex, previous colorectal cancer, underlying pathogenic variant, and interval since previous colonoscopy. Allocation concealment was ensured through the centralised web-based system. Patients were masked to group allocation until the start of withdrawal in procedures with mild sedation, or until completion of the procedure in procedures with propofol-based sedation. Endoscopists were not masked. The primary outcome was adenoma detection rate, defined as the proportion of patients with at least one histopathologically confirmed adenoma, analysed in the full analysis set (defined as all randomly allocated patients with available data for the primary outcome). The diagnostic performance of the CADx system was evaluated as a secondary outcome. The safety analysis set comprised all randomly allocated patients who underwent a study colonoscopy. This study is registered with the German Clinical Trials Register, DRKS00030695, and is completed. FINDINGS: Between May 9, 2023, and Oct 30, 2025, 757 patients were randomly allocated to HD-WL colonoscopy (377 patients) or to AI-assisted colonoscopy (380 patients); 733 patients were included in the full analysis set (369 HD-WL and 364 AI-assisted). The median age was 49 years (IQR 38-59) in the HD-WL group and 50 years (38-59) in the AI-assisted group; 213 (58%) were female and 156 (42%) male in the HD-WL group, and 207 (57%) were female and 157 (43%) male in the AI-assisted group. The adenoma detection rate was 30&#xb7;9% (114 of 369 patients) with HD-WL versus 33&#xb7;8% (123 of 364 patients) with CADe assistance (odds ratio 1&#xb7;14 [95% CI 0&#xb7;83-1&#xb7;57], p=0&#xb7;41). For CADx differentiation of neoplastic versus non-neoplastic lesions in the paired lesion-level analysis, with histopathology as the reference standard and sessile serrated lesions and traditional serrated adenomas classified as non-neoplastic, CADx sensitivity was 85&#xb7;9% (95% CI 82&#xb7;0-89&#xb7;1) and specificity was 91&#xb7;4% (89&#xb7;4-93&#xb7;0). Three adverse events occurred in the AI-assisted group: two mild post-polypectomy bleedings and one serious pulmonary embolism or deep venous thrombosis unrelated to the procedure. No adverse events occurred in the HD-WL group. INTERPRETATION: CADe-assisted colonoscopy did not show the absolute improvement in adenoma detection rate that was assumed in the prespecified sample-size calculation. CADx did not clearly improve lesion differentiation beyond expert optical diagnosis in expert Lynch syndrome surveillance settings. FUNDING: Third-party research funding of the National Center for Hereditary Tumor Syndromes, University Hospital Bonn.

Humans

Natural deep eutectic solvent in situ formation-based extraction method coupled to high-performance anion-exchange chromatography with pulsed amperometric detection for multiclass carbohydrates in hot pot bases.

A novel method was developed for the simultaneous extraction of fourteen multiclass carbohydrates from high-fat foods via the in situ formation of deep eutectic adducts from analytes and acetate ions. Different natural deep eutectic solvents (NADESs) composed of fructose and organic acids were tested as extraction solvents. A model NADES formulated with sodium acetate and fructose was characterized using Fourier transform infrared (FTIR) spectroscopy and hydrogen nuclear magnetic resonance (1H-NMR) spectroscopy. The critical extraction parameters were systematically optimized using multi-response surface methodology (MRSM) with a central composite design (CCD). The extract was analyzed using high-performance anion-exchange chromatography coupled with pulsed amperometric detection (HPAEC-PAD) using a sodium hydroxide-sodium acetate eluent, which did not require organic solvents. This approach exhibited good linearity over the concentration range of 0.02-10 mg L-1, with correlation coefficients (r) ranging from 0.9994 to 0.9999. The limits of detection and quantification were in the ranges of 0.06-0.42 mg kg-1 and 0.19-1.3 mg kg-1, respectively, which were significantly lower than those of liquid chromatography (LC). The protocol was successfully applied to the determination of fourteen carbohydrates in forty-five hotpot seasoning samples. The recoveries ranged from 86.3% to 104.1%, with relative standard deviations (RSDs) of 0.9-7.1%. By integrating multiple techniques, this strategy simplifies operations, shortens extraction time, and achieves baseline separation of three carbohydrate classes that exhibit poor resolution using a conventional LC method. This study describes an efficient procedure for the simultaneous determination of multiple trace-level carbohydrates in complex samples using HPAEC-PAD.

Journal Article

Impact of subthreshold troponin levels and temporal trends on short term adverse cardiovascular outcomes in patients discharged from the emergency department: a RACE-IT trial substudy.

BACKGROUND: High-sensitivity cardiac troponin I assays enable early exclusion of myocardial infarction in the emergency department. However, the clinical implications of detectable troponin values below the 99th percentile upper reference limit (4-18 ng/L) remain unclear. OBJECTIVE: To assess the association between subthreshold troponin levels and 30-day outcomes in patients from the RACE-IT trial, using exact troponin values when available. METHODS: This post-hoc analysis of the RACE-IT stepped-wedge randomized controlled trial included patients with troponin&#x2009;&#x2264;&#x2009;18 ng/L across nine EDs. Patients were stratified by initial troponin, peak value, absolute change, and percent change. The primary outcome was a 30-day composite of all-cause death, acute MI, percutaneous coronary intervention, and coronary artery bypass grafting. Logistic regression analysis after adjusting for age, sex, race, and coronary artery disease was performed. RESULTS: Among 19,194 patients with troponin&#x2009;&#x2264;&#x2009;18 ng/L, 117 (0.6%) experienced the composite outcome. Higher troponin levels were associated with increased event rates in unadjusted analyses. Adjusted analyses showed no independent associations overall, though patients whose highest troponin values fell within the&#x2009;&#x2265;&#x2009;11-&#x2009;&#x2264;&#x2009;18 ng/L range continued to demonstrate significantly worse outcomes than those with lower peak levels. Elevated troponin values correlated with older age, male sex, and greater comorbidity burden. CONCLUSION: In this post-hoc analysis of patients with troponin values below the 99th percentile URL, absolute levels and temporal changes were not independently associated with 30-day adverse outcomes. These findings support the use of subthreshold troponin values in rapid rule-out protocols, emphasizing the need to consider clinical context and comorbidities in risk assessment.

Humans

Enhancing Hemoglobin Bart's hydrops fetalis syndrome prevention: a single-tube multiplex real-time PCR assay for the comprehensive detection of four significant &#x3b1;0-thalassemia deletions (--SEA, --THAI, --CR, and --SA) found in Thailand.

BACKGROUND: Hemoglobin (Hb) Bart's hydrops fetalis is a major public health concern in Southeast Asia, particularly in Thailand. Current screening strategies target the two most common &#x3b1;0 -thalassemia deletions (--SEA and --THAI). METHOD: In this study, we developed a single-tube multiplex real-time PCR assay for the simultaneous detection of four clinically relevant &#x3b1;0-thalassemia deletions (--SEA, --THAI, --CR, and --SA). The assay was validated using 538 clinical samples with diverse thalassemia genotypes and compared against conventional gap-PCR as the reference method. Analytical performance, including sensitivity, specificity, and limit of detection (LOD), was evaluated. In addition, clinical utility was assessed in 22 prenatal diagnosis cases at risk of Hb Bart's hydrops fetalis. RESULTS: The study cohort demonstrated substantial genetic heterogeneity, comprising 43 distinct genotypes. The developed assay achieved 100% sensitivity and specificity for all targeted deletions, with complete concordance with gap-PCR results. No cross-reactivity was observed with &#x3b1;+-thalassemia. The assay demonstrated a high analytical sensitivity with a LOD of 9.76&#x2009;&#xd7;&#x2009;10-3&#x2009;ng per reaction. Whereas in prenatal diagnosis, all 22 fetal genotypes were accurately identified, including five cases of homozygous --SEA and one rare compound heterozygous --SEA/--CR fetus. CONCLUSIONS: This study presents a rapid, accurate, and cost-effective multiplex real-time PCR assay capable of detecting both common and rare &#x3b1;0-thalassemia deletions in a single reaction. The assay demonstrates strong potential for implementation in routine clinical laboratories and large-scale population screening, contributing to improved prevention and control of severe thalassemia syndromes in high-prevalence regions.

Humans