Search PubMedSearch

SEARCH · Search PubMed

Results for “MM”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

76 records · Page 4Linked to original sources

Optimizing focal vibration therapy for balance and gait: A systematic review.

OBJECTIVE: This systematic review evaluated the efficacy of focal (localized) vibration therapy (FVT) applied to muscles/tendons on balance, gait, and mobility, with a specific focus on defining optimal vibration protocols (frequency, amplitude, dosing) and muscle-targeting strategies to maximize sensorimotor recovery. METHODS: A systematic review was conducted across six databases (CINHAL, Embase, Medline, Web of Science, Scopus, CENTRAL) from January 2000 to May 2025. Studies were included if they involved human participants, applied FVT therapeutically, and reported balance, gait, or mobility outcomes. Data extraction included study characteristics, intervention protocols, and outcomes. Methodological quality was assessed using the PEDro scale. RESULTS: Sixty-two studies (n = 2090 participants) were included. Methodological quality assessment (PEDro scale) indicated 44% of studies met high-quality standards. Biomechanical analysis identified the quadriceps, gastrocnemius/soleus, and plantar muscles as the most effective vibration sites, given their critical roles in gait propulsion and postural stability. The synthesis of protocol data indicated a promising therapeutic window characterized by a vibration frequency of 80-120 Hz (primarily fixed sinusoidal waveforms at a single frequency) and an amplitude of 0.2-0.5 mm (reported only in 12 studies; amplitude was not reported in 23 studies), applied bilaterally for a minimum of 3 sessions per week over 4-12 weeks, which could lead to improved balance and gait performance with benefits sustained for up to 5 months. CONCLUSION: FVT shows potential to improve gait and balance, particularly when targeting lower-extremity muscles with optimized vibration parameters. To advance the field, future research must prioritize the development of standardized protocols and investigate neurophysiological mechanisms to refine FVT as a precision bioengineering solution for mobility deficits.

Humans

Ciliochoroidal Effusion and Regional Scleral Thickening in Peripapillary Pachychoroid Syndrome.

PURPOSE: To assess anterior scleral thickness and the presence of ciliochoroidal effusion (CE) in eyes with peripapillary pachychoroid syndrome (PPS), and to compare the results with a cohort of healthy age-matched controls. DESIGN: Retrospective cross-sectional study METHODS: A total of 20 eyes from 12 patients diagnosed with PPS and 30 eyes from 15 healthy control subjects. All participants underwent a comprehensive ophthalmic examination, including spectral-domain optical coherence tomography with enhanced depth imaging (EDI-OCT) and anterior segment OCT (AS-OCT). Choroidal thickness was measured at predefined macular and peripapillary locations, while anterior scleral thickness was assessed 6 mm posterior to the scleral spur in 4 quadrants. Ciliochoroidal effusion was evaluated qualitatively using AS-OCT. Comparisons between groups were performed using linear mixed models with Bonferroni correction (scleral thickness corrected P < .010) RESULTS: The mean age of PPS patients was 75.6 &#xb1; 9.8 years, and 16% were females. Anterior scleral thickness was significantly greater in the temporal quadrant in PPS eyes compared to controls (396.85 &#xb1; 74.97 &#xb5;m vs 331.13 &#xb1; 62.65 &#xb5;m: P = .007). Ciliochoroidal effusion was detected in 60% of PPS eyes, predominantly in the superior and temporal sectors, whereas no effusion was observed in healthy controls (P < .001). Eyes with CE exhibited a thicker mean scleral thickness and a thicker subfoveal choroidal thickness compared to eyes without effusion (P < .05). CONCLUSION: Eyes with PPS demonstrated increased temporal scleral thickness and a high prevalence of CE. These findings suggest that scleral characteristics may represent a predisposing anatomical factor in PPS, although the precise pathophysiological mechanisms remain to be elucidated.

Humans

Simultaneous determination of imiquimod and terbinafine in skin permeation studies: Validation of a liquid chromatography method with fluorescence detection.

Chromoblastomycosis is a chronic, neglected subcutaneous mycosis posing significant therapeutic challenges. A topical strategy combining terbinafine (TBF), an antifungal, with imiquimod (IMQ), a TLR-7/8 agonist immunomodulator, has emerged a promising alternative. However, no validated analytical method is currently available to simultaneously quantify both drugs in skin, which is crucial for novel formulation development. This study reports the development and validation of a simple HPLC method with fluorescence detection (excitation 236&#xa0;nm, emission 340&#xa0;nm) for the simultaneous determination of TBF and IMQ extracted from porcine skin. Separation was achieved on a C8 reversed-phase column (125&#xa0;&#xd7;&#xa0;4.0&#xa0;mm, 5&#xa0;&#x3bc;m) using a mobile phase of methanol and water (60,40, v/v), both containing 0.1% formic acid at a flow rate of 0.8&#xa0;mL/min. The method showed excellent linearity (r&#xa0;>&#xa0;0.999) over 0.01-1.0&#xa0;&#x3bc;g/mL for IMQ and 0.1-2.0&#xa0;&#x3bc;g/mL for TBF. Intra- and inter-day precision demonstrated coefficients of variation below 5%, and recovery rates from skin (79-105%) confirmed accuracy. Limits of detection were 0.001&#xa0;&#x3bc;g/mL for IMQ and 0.004&#xa0;&#x3bc;g/mL for TBF, with quantification limits of 0.02&#xa0;&#x3bc;g/mL and 0.16&#xa0;&#x3bc;g/mL, respectively. This selective, sensitive, and reproducible method represents a valuable analytical tool for supporting the development and quality control of topical formulations for chromoblastomycosis and other fungal skin diseases.

Animals

Genome-wide identification of CXE gene family in soybean and functional characterization of GmCXE31 in lipid biosynthesis and salt tolerance.

GmCXE31 negatively regulates salt tolerance and lipid synthesis in soybean, and the cxe31-edited lines improve soybean yield and seed quality. Carboxylesterases (CXEs), as essential lipid hydrolases of the &#x3b1;/&#x3b2;-hydrolase fold superfamily, are critical for plant stress responses, hormone signaling and secondary metabolism. The key candidate gene GmCXE31 was previously identified in our laboratory through a genome&#x2011;wide association study (GWAS) of soybean lipid&#x2011;related traits. In the present study, we further identified 60 GmCXE family genes in soybean. Phylogenetic analysis clustered them into 11 conserved subfamilies. Cis-acting element analysis showed their promoters are enriched with elements related to abiotic stress, growth and hormone signaling, suggesting potential roles in soybean development and stress adaptation. GmCXE31 is highly expressed in seedling roots and responsive to strigolactones (SLs) and salt stress. Functional assays revealed that GmCXE31 negatively regulates soybean salt tolerance: its overexpression reduced salt tolerance in Arabidopsis and soybean under 150&#x202f;mM NaCl stress, while its knockout enhanced this trait. Lipid profiling revealed GmCXE31-edited lines had higher seed oil content, elevated oleic/linoleic acid ratio and lower saturated fatty acid proportion, which was achieved by regulating lipid synthesis-related genes like GmNFYA. Agronomic trait analysis showed GmCXE31-edited lines had increased nodule number, plant height and single-plant yield at maturity, with opposite phenotypes in overexpression lines. In conclusion, this study elucidates the multifaceted roles of GmCXE31 in coordinating soybean salt tolerance, lipid metabolism and agronomic traits, providing theoretical and genetic resources for salt-tolerant and high-quality soybean molecular breeding.

Glycine max

Postoperative chemoradiotherapy in Wilms tumor with concurrent lung and lymph node metastasis.

BACKGROUND: An effective treatment strategy is essential for metastatic Wilms tumor (WT) management. To improve prognostic accuracy, this study examined metastatic patterns and key prognostic factors. METHODS: Children diagnosed with WT from 2010 to 2021 were identified from the SEER database. All patients underwent chemotherapy and surgical resection. Metastatic patterns, metastasis-related predictors, and prognostic factors were evaluated. RESULTS: Of the 1040 patients analyzed, 226 (21.7%) experienced lung metastasis, 31 (3.0%) liver metastasis, 6 (0.6%) bone metastasis, and 220 (21.2%) regional lymph node metastasis. Distant metastasis was associated with a higher incidence of lymph node metastasis (OR = 1.506, 95% CI 1.346-1.685, p < 0.001). Age 3-17 years (OR = 1.933, 95% CI 1.406-2.680, p < 0.001), left-sided (OR = 1.383, 95% CI 1.016-1.890, p = 0.040), bilateral (OR = 2.303, 95% CI 1.215-4.243, p = 0.009), and tumor size &#x2265;135 mm (OR = 2.020, 95% CI 1.481-2.749, p < 0.001) were identified as predictors of metastasis. Both lymph node (p < 0.001) and lung metastasis (p < 0.001) were high-risk factors for WT. Radiotherapy provided long-term survival benefits for the metastatic population (p = 0.027), while postoperative chemotherapy showed better outcomes than preoperative or other strategies (p < 0.001). Further analysis demonstrated that the concurrent lung and lymph node metastasis group benefited more from postoperative chemoradiotherapy, with HRs of 0.226 (p = 0.028) for overall survival and 0.255 (p = 0.048) for cancer-specific survival. CONCLUSION: WT with concurrent lung and lymph node metastasis represents a distinct and aggressive metastatic phenotype associated with a significantly poor prognosis. Postoperative chemoradiotherapy may provide superior survival benefits for this high-risk population.

Humans

Indications, Techniques and Complications Associated With Pterygoid Implants: A Systematic Review and Meta-Analysis.

BACKGROUND AND OBJECTIVES: Pterygoid implants represent a graftless option for rehabilitation of patients with posterior maxillary atrophy, engaging the dense cortical bone of the pterygomaxillary complex. Despite clinical growth, a comprehensive synthesis of indications, surgical techniques, and complications is lacking. This review evaluated the prevalence of complications, implant survival rates, and marginal bone loss (MBL) associated with pterygoid implant placement. METHODS: The reporting of this review follows PRISMA 2020 guidelines. Six electronic databases (PubMed, Ovid, Scopus, WoS, CENTRAL, and Dentistry & Oral Sciences Source) were searched from 1 January 2020 to 31 December 2025. Included criteria comprised randomized and non-randomized clinical studies reporting outcomes of pterygoid implants (&#x2265;&#x2009;13&#x2009;mm) in adult patients with posterior maxillary atrophy (minimum 10 implants). Risk of bias was assessed using JBI critical appraisal checklists. Proportions were pooled using the Freeman-Tukey double arcsine transformation under a random-effects model. Certainty of evidence was assessed using GRADE. RESULTS: Seventeen studies reporting 846 patients and 1915 pterygoid implants were included. The pooled survival rate was 97.9% (95% CI: 97.1%-98.6%; I2&#x2009;=&#x2009;0%; 14 studies) and the overall failure rate was 2.1% (95% CI: 1.4%-3.0%). Early failure rate was 0.9% (95% CI: 0.0%-3.0%; I2&#x2009;=&#x2009;59.5%). Late failure and MBL were summarized narratively. Certainty of evidence was low to very low. CONCLUSIONS: Pterygoid implants demonstrate excellent survival (97.9%) and low failure rates (2.1%), primarily early, supporting their reliability as a graftless solution for posterior maxillary atrophy. Complications appear infrequent though heterogeneously reported. Low evidence certainty necessitates prospective studies with standardized outcome reporting.

Humans

The effect of combining visuo-vestibular exercises with manual therapy and exercise on sensorimotor function in chronic neck pain: A randomized controlled trial.

OBJECTIVE: To investigate whether adding visuo-vestibular exercises to standard manual therapy and exercise produces superior improvements in sensorimotor function, pain, balance, and functional disability in adults with chronic neck pain. METHODS: This prospective, randomized controlled trial enrolled 58 adults with chronic neck pain (&#x2265;3 months) allocated to a manual therapy and exercise group (MtE; n&#x202f;=&#x202f;29) or MtE plus visuo-vestibular exercises (MtE-VVE; n&#x202f;=&#x202f;29). Both groups completed 12 supervised sessions over six weeks with a daily home exercise programme. Outcomes were assessed at baseline, 6 weeks, and 12 weeks, and included pain intensity (Visual Analog Scale [VAS]), upper extremity reaction time, computerized posturography, the Neck Disability Index (NDI), and cervical muscle endurance. RESULTS: Fifty-four participants (27 per group) completed the study. Both groups improved significantly across all outcomes (p&#x202f;<&#x202f;0.001). At 12-week follow-up, the MtE-VVE group demonstrated superior outcomes: activity-related pain was reduced by an additional 2.00&#x202f;cm (95% CI: 0.75-3.25; p&#x202f;=&#x202f;0.005), bilateral reaction time improved by 1.70&#x202f;s (p&#x202f;=&#x202f;0.001), eyes-open mediolateral sway decreased by 0.50&#x202f;mm (p&#x202f;<&#x202f;0.001), NDI score was 6.30 points lower (95% CI: 3.42-9.18; p&#x202f;<&#x202f;0.001), and cervical flexion and extension endurance improved by 12.00&#x202f;s and 27.70&#x202f;s, respectively (p&#x202f;&#x2264;&#x202f;0.020). CONCLUSION: Adding visuo-vestibular exercises to standard manual therapy and exercise produces clinically meaningful and sustained improvements in activity-related pain, sensorimotor function, postural control, and functional disability in adults with chronic neck pain, and may be recommended as an effective adjunctive intervention.

Humans

Phenotypic, physiological and transcriptomic analysis of graded salt stress responses in Pyrus betulifolia Bunge and functional characterization of the hub gene PbSTY46.

Pyrus betulifolia Bunge is a salt&#x2011;tolerant rootstock for pear, but its salt&#x2011;tolerance mechanisms remain largely unknown. In this study, P. betulifolia seedlings were subjected to graded NaCl stress at concentrations of 0 (CK), 50 (T1), 100 (T2), and 200 (T3) mM. We integrated phenotypic observation, physiological assessment, transcriptomic profiling, and functional gene validation to systematically elucidate its salt tolerance mechanisms. Salt stress inhibited seedling growth and root traits in a concentration-dependent manner, and T3 caused the most severe damage. Osmotic solutes responded differentially: soluble sugars peaked under T2, while proline peaked under T3. Antioxidant enzymes showed tissue-specific biphasic responses and declined after prolonged T3 stress. Meanwhile, chlorophyll and photosynthesis decreased, whereas anthocyanin increased, indicating a metabolic shift from photosynthesis to photoprotection. Transcriptome analysis revealed distinct responses depending on stress intensity: mild stress induced membrane lipid remodeling, moderate stress activated circadian rhythm and hormone signaling, and severe stress enhanced phenylpropanoid biosynthesis and thiamine metabolism. Gene Set Enrichment Analysis (GSEA) further highlighted progressive enrichment of phenylpropanoid biosynthesis, heme binding, and oxidoreductase activity. Weighted Gene Co&#x2011;expression Network Analysis (WGCNA) identified a blue module significantly positively correlated with root traits, from which the hub gene PbSTY46 was identified. Functional validation via overexpression, loss&#x2011;of&#x2011;function mutants, and pharmacological interventions (MeJA/DIECA) confirmed that PbSTY46 acts through JA signaling to enhance antioxidant enzyme activities and thereby confer salt tolerance. Collectively, P. betulifolia adopts a "survival&#x2011;first" strategy that coordinates growth arrest, osmotic homeostasis, and ROS scavenging. These findings establish PbSTY46 as a key regulator that links JA signaling to antioxidant defense. Thus, PbSTY46 represents a promising candidate for marker&#x2011;assisted breeding of salt&#x2011;tolerant pear cultivars.

Salt Stress

Novel non-contrast computed tomography parameters for predicting spontaneous stone passage and surgical requirement in ureteral stones: The role of ureteral wall thickness and dilatation ratio.

We investigated the predictive value of standard non-contrast computed tomography (NCCT) measurements, the ureteral dilatation ratio (DDR) and intraluminal urine stasis markers, for spontaneous stone passage (SSP) versus surgical intervention in patients with ureteral stones. We also evaluated ureteral wall thickness (UWT) as a practical clinical marker. This retrospective study included 461 patients diagnosed with ureteral stones via NCCT. Patients were categorised into two groups based on clinical outcomes: the spontaneous passage group (MET; n&#x2009;=&#x2009;229) and the endoscopic surgery group (URS; n&#x2009;=&#x2009;232). Stone volume, stone density (HU), UWT, DDR and intraluminal urine attenuation values were measured for all patients. Independent risk factors were identified using a multivariate logistic regression model and clinical cut-off values were determined via ROC curve analysis. Stone volume, density, UWT and hydronephrosis grade were all significantly higher in the URS group. Multivariate regression analysis revealed that increased UWT (OR: 5.03, 95% CI: 3.66-6.90; p&#x2009;<&#x2009;0.001) was the strongest independent predictor of surgery. Higher DDR (OR: 1.88; p&#x2009;=&#x2009;0.003), advanced hydronephrosis, stone volume, and density also increased surgical risk. A UWT cut-off &#x2265;&#x2009;2.97&#xa0;mm predicted surgery with 84.8% sensitivity and 84.3% specificity (AUC: 0.872). A DDR cut-off >&#x2009;1.79 yielded 81.7% specificity and 40.4% sensitivity. UWT weakly correlated with stone volume (r&#x2009;=&#x2009;0.145), indicating wall thickening reflects an inflammatory response rather than a mere mechanical consequence. UWT is a superior predictor of SSP failure, supported by increased DDR as a highly specific complementary risk factor. These parameters could help clinicians to identify patients who would benefit from early surgical counselling and intervention rather than prolonged conservative management.

Humans

Clinical Trial: Effectiveness and Safety of a Novel Anal Insert Device for Treatment of Faecal Incontinence.

BACKGROUND: Treatment options for medically-refractory faecal incontinence (FI)-including anorectal biofeedback, dextranomer injection, and sacral nerve stimulation-are limited and outcomes are often suboptimal. Anal or vaginal insert devices are infrequently used. AIMS: We evaluated the safety and effectiveness of a new anal insert device (StaySure) in patients with FI. METHODS: Patients with FI for&#x2009;&#x2265;&#x2009;6&#x2009;months and&#x2009;&#x2265;&#x2009;4 moderate or large FI episodes during a 4-week baseline entered a 2-4&#x2009;week fitting/run-in period to individualise device size (10 or 13&#x2009;mm) followed by a 4-week treatment period. Outcomes included effectiveness, safety, and quality of life (QoL). The primary outcome was the proportion achieving a&#x2009;&#x2265;&#x2009;50% reduction in FI frequency. RESULTS: Of 124 enrolled patients, 98, 71, and 61 progressed through the baseline, fitting/run-in, and treatment phases respectively, with few exclusions due to device intolerance. In the intent-to-treat cohort of 59 participants (93% women), mean (SD) number of days with FI declined from 13.2 (7.0) to 6.3 (6.9), and FI weekly episodes declined from 5.4 (6.9) to 2.1 (5.1) (69% reduction; p&#x2009;<&#x2009;0.001) with similar results for both device sizes. The primary endpoint was achieved in 76.3% of participants; 54.2% achieved&#x2009;&#x2265;&#x2009;75% reduction. The FIQoL overall score increased from a mean (SD) of 1.9 (0.6) to 2.3 (0.6) (p&#x2009;<&#x2009;0.001), indicating improved QoL. Improvements in FI frequency, FIQoL exceeded minimal clinically important difference thresholds, confirming clear clinical benefit. No treatment-related serious adverse events were reported. CONCLUSIONS: The StaySure anal insert device is safe, well tolerated, and effective in reducing FI in patients with moderate to severe symptoms refractory to conservative therapies. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT03898778.

Adult

Risk factors and management strategies for needle disengagement from the visual field in pediatric robot-assisted laparoscopic pyeloplasty.

OBJECTIVE: This study aimed to identify risk factors for suture needle disengagement from the visual field during pediatric robot-assisted laparoscopic pyeloplasty (RALP) and propose effective strategies for prevention and management. METHODS: A retrospective cohort study analyzed clinical data from 339 pediatric patients who underwent RALP for ureteropelvic junction obstruction (UPJO) at a single institution between August 2017 and December 2020. Patients were categorized based on the occurrence of needle disengagement from the visual field. Various patient demographics and surgical procedural factors were evaluated. Univariate and multivariate logistic regression, along with LASSO regression, identified independent risk and protective factors. RESULTS: Needle disengagement occurred in 38 (11.21%) of 339 cases. Multivariate logistic regression identified five independent risk factors for needle disengagement: use of a 3-mm auxiliary trocar (OR = 4.69, 95% CI: 1.98-12.53, P < 0.001), non-standard needle holder use (OR = 2.32, 95% CI: 1.04-5.18, P = 0.038), unshaped suture needles (OR = 3.16, 95% CI: 1.44-7.19, P = 0.005), simultaneous use of &#x2265;2 intra-abdominal sutures (OR = 2.46, 95% CI: 1.15-5.48, P = 0.023), and clamping the needle shank during withdrawal (OR = 3.42, 95% CI: 1.40-8.21, P = 0.006). Conversely, sufficient assistant experience (>10 cases) was identified as a protective factor (OR = 0.39, 95% CI: 0.18-0.88, P = 0.021). CONCLUSION: Suture needle disengagement from the visual field during pediatric RALP is associated with specific technical and instrumental factors. Implementing targeted strategies-such as mandating specialized needle holders, preoperative needle shaping, a single-needle workflow, prioritizing clamping the suture thread over the needle shank during withdrawal, and ensuring adequate assistant training-has the potential to significantly reduce significantly mitigate the risk of needle loss and enhance overall surgical safety in pediatric RALP.

Humans

Clinical Performance of Bulk-Fill Versus Incremental Composite Placement Approaches in Vital Posterior Teeth: A 24&#x2009;Months Randomized Controlled Trial.

BACKGROUND: Composite resin placement technique may influence marginal integrity, polymerization stress distribution, and long-term clinical performance of posterior restorations. This randomized controlled clinical trial evaluated the 24-month clinical performance of four different placement techniques in Class I posterior composite restorations. METHODS: Fifty patients aged 20-35&#x2009;years presenting with four occlusal carious lesions each were enrolled, resulting in 200 restorations. Cavities (4-5&#x2009;mm depth) were prepared according to caries extension. Restorations were randomly allocated into four equal groups (n&#x2009;=&#x2009;50) according to placement technique: stamp technique, snowplow technique, modified incremental "pizza" technique, and bulk-fill technique. All materials were applied following manufacturers' instructions. Clinical evaluation was performed at baseline and after 6, 12, and 24&#x2009;months using FDI criteria. Functional (fracture/retention, marginal adaptation), esthetic (marginal staining, anatomical form), and biological (postoperative sensitivity, secondary caries) properties were assessed by two calibrated evaluators. Statistical analysis was performed at a significance level of &#x3b1;&#x2009;=&#x2009;0.05. RESULTS: Thirty-eight patients with a total of 152 restorations were evaluated at the end of the 24&#x2009;months in line with FDI at the end of the study with 76% recall rates. No statistically significant differences were observed among groups regarding fracture/retention or secondary caries (p&#x2009;>&#x2009;0.05). Marginal adaptation and marginal staining demonstrated minor deterioration over time across all groups, with statistically significant intergroup differences found (p&#x2009;<&#x2009;0.05). Postoperative sensitivity was minimal and transient in all groups with no significant difference (p&#x2009;=&#x2009;0.181). CONCLUSIONS: Within the limitations of this 24-month follow-up, the four placement techniques demonstrated comparable clinical performance in Class I posterior composite restorations. Selection of technique may therefore be guided by clinical preference and procedural efficiency rather than differences in short-term clinical outcomes. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT07415317.

Humans

Comfort and Usability of Digital Versus Conventional Custom-Fit Mouthguards: A Randomized Clinical Trial.

BACKGROUND/OBJECTIVES: The use of mouthguards protects teeth and the supporting tissues against impacts. Digital impressions and 3D-printed models can reduce manufacturing steps and minimize discomfort. This study evaluated the fit, comfort, and usability of custom-made mouthguards, obtained by conventional and digital workflow, in amateur athletes. MATERIALS AND METHODS: Amateur athletes were recruited for this randomized, double-blind, crossover clinical study. Each participant received two 4-mm-thick custom-fit mouthguards made of ethylene vinyl acetate (EVA) sheets using two protocols: conventional impression using alginate to produce dental stone cast (CMP) and intraoral digital scanning to produce 3D-printed resin models (DMP). Each mouthguard was worn during all training and matches over 3&#x2009;months. The order of mouthguard use was randomly assigned. Patient satisfaction with the impression protocol and mouthguard use, model accuracy, and mouthguard fit were assessed. RESULTS: Overall, 46 participants completed the study. The DMP protocol required less execution time (p&#x2009;=&#x2009;0.023), caused less discomfort (p&#x2009;=&#x2009;0.018), anxiety (p&#x2009;=&#x2009;0.008), nausea (p&#x2009;=&#x2009;0.027), difficulty breathing (p&#x2009;<&#x2009;0.001), and unpleasant taste (p&#x2009;=&#x2009;0.006) compared to the CMP protocol. The pain (p&#x2009;=&#x2009;0.971) perceived by the participants was similar in both impression protocols. The CMP-mouthguards were considered to be better fitting by the majority of participants (p&#x2009;=&#x2009;0.027). Between-group comparisons revealed that DMP-mouthguard caused less discomfort immediately postadaptation (p&#x2009;=&#x2009;0.034), with no significant differences observed at 30 or 90&#x2009;days. CONCLUSIONS: The digital workflow demonstrated to be efficient in the fabrication of mouthguards. Digital impression was more comfortable, requiring less execution time, with more accurate printed models and produced mouthguards with reported comfort and fit levels similar to those manufactured conventionally.

Humans

First evaluation of a novel recombinant eCG molecule in ewes reveals a discrepancy between ovulatory response and pregnancy outcome.

This study evaluated the reproductive performance and clinical safety of a novel recombinant eCG (r-eCG) in ewes. Two weeks prior to study onset (Day 0: intravaginal progesterone device insertion), 45 ewes were randomly assigned to negative control (NC; no eCG; n&#x202f;=&#x202f;10), positive control (PC; 400IU commercial non-recombinant eCG; n&#x202f;=&#x202f;20), or treatment group (T; 400IU r-eCG; n&#x202f;=&#x202f;15). Ewes were inseminated with fresh-diluted semen (200&#x202f;&#xd7;&#x202f;106 sperm). Ultrasonography assessed follicle count/diameter (days 11, 13), ovulation (day 13), corpus luteum (CL) number/characteristics (day 20), and pregnancy (day 44). Serum progesterone was measured on day 20; Group T underwent clinical/hematological evaluations (days 0, 20, and 44). Estrus signs were more frequent (P&#x202f;<&#x202f;0.01) in T (100%) than NC (50%), while PC (85%) did not differ. Ovulation rates were similar between T (93%) and PC (95%), but higher than NC (50%; P&#x202f;<&#x202f;0.05). On day 13, largest follicle diameter did not differ (P&#x202f;>&#x202f;0.05) among groups; however, fewer follicles > 2&#x202f;mm occurred in PC than NC and T (P&#x202f;<&#x202f;0.05). CL number was higher in T than PC (2.0&#x202f;&#xb1;&#x202f;0.3 vs. 1.0&#x202f;&#xb1;&#x202f;0.0, P&#x202f;<&#x202f;0.01), while NC did not differ (1.0&#x202f;&#xb1;&#x202f;0.25). Conversely, pregnancy rate was higher (P&#x202f;<&#x202f;0.05) in PC (70%) than T (28.6%) and NC (20%). Among ovulated ewes, progesterone concentration and progesterone/CL ratio did not differ among groups (P&#x202f;=&#x202f;0.92 and P&#x202f;=&#x202f;0.08, respectively). No relevant r-eCG-related clinical or hematological alterations occurred. In conclusion, 400IU r-eCG effectively induces estrus and ovulation without adverse effects; however, the discrepancy between ovulatory response and pregnancy rate underscores the need for further study refinement to improve fertility.

Animals

Comparative effectiveness of percutaneous coronary intervention strategies for coronary small-vessel disease: a network meta-analysis of randomized trials.

BACKGROUND: Coronary small-vessel disease (SVD) remains challenging for percutaneous coronary intervention (PCI) because small lumens magnify restenosis and ischemic risk. Multiple devices are available, yet their comparative performance is uncertain. This study evaluated and ranked PCI strategies for SVD. METHODS: A systematic review and network meta-analysis was conducted in accordance with PRISMA. PubMed, Embase, the Cochrane Central Register of Controlled Trials, Web of Science, and Google Scholar were searched from inception to 15 August 2025. Eligible studies were English-language randomized controlled trials enrolling adults with angiographic SVD defined as reference vessel diameter &#x2264;3.0&#x2009;mm, comparing PCI strategies, and reporting target lesion revascularization (TLR), binary restenosis (BR), or myocardial infarction (MI). A frequentist random-effects network meta-analysis generated odds ratios (ORs) with 95% confidence intervals (CIs) and treatment rankings using the surface under the cumulative ranking curve (SUCRA). RESULTS: Thirty-nine trials including 14,503 patients met the criteria. For TLR (37 studies; 11,980 patients), the highest SUCRA values were observed with sirolimus-eluting stents (SES 90.1%), zotarolimus-eluting stents (ZES 83.9%), and everolimus-eluting stents (EES 82.2%). For BR (32; 6,468), SES, ZES, and paclitaxel-coated balloons (DCB-PTX) ranked highest (95.0%, 80.0%, and 78.3%). For MI (37; 11,602), SES, DCB-PTX, and ZES ranked highest (79.0%, 78.7%, and 68.5%). Representative effects showed SES reduced TLR versus bare-metal stents (BMS) (OR, 0.25; 95% CI, 0.15-0.43) and MI versus BMS (OR, 0.41; 95% CI, 0.21-0.79). Conventional approaches such as BMS, plain old balloon angioplasty (POBA), and gold-plated balloon angioplasty (GPBA) ranked lowest across outcomes. CONCLUSION: SES provides the most consistent clinical benefit for coronary SVD. ZES, EES, and DCB-PTX are effective alternatives in selected settings, whereas BMS, POBA, and GPBA are less effective. These findings offer comparative evidence to guide device selection in SVD.

Humans

Vestibular schwannoma associated normal pressure hydrocephalus: clinical features and shunt responsiveness compared with idiopathic NPH.

BACKGROUND: Vestibular schwannoma (VS) is commonly associated with obstructive hydrocephalus due to mass effect; however, a rarer communicating form resembling normal pressure hydrocephalus (NPH) has also been described, possibly related to impaired CSF absorption from elevated CSF protein. We aimed to characterize the clinical and imaging features of VS-associated NPH (VS-NPH) and compare them with those of an idiopathic NPH (iNPH) cohort. METHODS: We retrospectively analyzed 18 patients with VS-NPH identified between 2008 and 2024. For comparison, 41 iNPH patients were drawn from a prospective longitudinal study at our center. Variables included demographics, tumor size, VS treatment modality, CSF parameters, Radscale imaging features, and shunt responsiveness. RESULTS: VS-NPH patients had markedly higher CSF protein levels than patients with iNPH (median 100 vs. 51&#xa0;mg/dL, p&#xa0;<&#xa0;0.001). Radiological features largely overlapped; however, parasagittal sulcal narrowing was more frequent in VS-NPH (61&#xa0;% vs.13&#xa0;%, p&#xa0;=&#xa0;0.002). These differences remained significant in the sensitivity analysis excluding the two patients without gait impairment. VS-NPH patients were younger in the primary analysis (66.8 vs. 72.0&#xa0;years, p&#xa0;=&#xa0;0.03), while exploratory associations between larger tumor size and both earlier NPH symptom onset (r&#xa0;=&#xa0;-0.48, p&#xa0;=&#xa0;0.049) and smaller callosal angle (r&#xa0;=&#xa0;-0.49, p&#xa0;=&#xa0;0.048) attenuated to non-significant trends in the sensitivity analysis. Tumor size was&#xa0;<&#xa0;30&#xa0;mm in 89&#xa0;% of patients. Ventriculoperitoneal shunt (VPS) resulted in clinical improvement in both groups, although response rates were numerically lower in VS-NPH than in iNPH (63&#xa0;% vs.75&#xa0;%). CTT was positive in 9 of 11 VS-NPH patients who underwent testing, although improvement after shunting also occurred in patients with negative CTT results or without prior CTT. CONCLUSIONS: VS-NPH may represent a secondary subtype of NPH with distinct biochemical and subtle imaging features. Elevated CSF protein may contribute to altered CSF dynamics. These findings are exploratory and require confirmation in larger prospective studies.

Humans

ALID score for treatment-effect heterogeneity of adjunctive low-voltage area ablation in persistent atrial fibrillation: A post hoc analysis of SUPPRESS-AF.

BACKGROUND: In persistent atrial fibrillation (AF), the incremental benefit of adjunctive low-voltage area (LVA) ablation beyond pulmonary vein isolation (PVI) remains inconsistent. OBJECTIVE: To examine whether a simple clinical score characterizes treatment-effect heterogeneity of adjunctive LVA ablation among patients with mapped LVA&#xa0;>&#xa0;5&#xa0;cm2 and to perform an exploratory supportive analysis in an independent randomized cohort. METHODS: In this post-hoc analysis of SUPPRESS-AF, which included patients with persistent AF and mapped LVA&#xa0;>&#xa0;5&#xa0;cm2 after PVI, four variables-age&#xa0;&#x2265;&#xa0;75&#xa0;years, left atrial diameter&#xa0;>&#xa0;44&#xa0;mm, estimated glomerular filtration rate&#xa0;<&#xa0;60&#xa0;mL/min/1.73&#xa0;m2, and absence of diabetes-were combined into the ALID score (0-4). Patients were stratified into low (0-1), intermediate (2), and high (3-4) score groups. Because EARNEST-PVI did not use LVA-guided ablation or select patients based on mapped LVA, it was analyzed as an exploratory supportive cohort rather than as an external validation cohort. RESULTS: In SUPPRESS-AF (n&#xa0;=&#xa0;336), a significant treatment-by-score interaction was observed (P&#xa0;<&#xa0;0.001). Adjunctive LVA ablation was associated with increased recurrence in the low-score stratum (HR 3.92; 95% CI 1.50-10.20) and reduced recurrence in the high-score stratum (HR 0.48; 95% CI 0.26-0.86). In EARNEST-PVI (n&#xa0;=&#xa0;494), a qualitatively similar interaction pattern was observed for additional ablation beyond PVI (interaction P&#xa0;=&#xa0;0.029), although the ablation strategy differed from LVA-guided ablation. CONCLUSIONS: Among patients with persistent AF and mapped LVA >5&#xa0;cm2, the ALID score identified heterogeneity in response to adjunctive LVA ablation. These hypothesis-generating findings require prospective validation before clinical implementation.

Humans

Comparison of short-term clinical outcomes and patient satisfaction between intraoral scanning and conventional impressions for complete-arch implant prostheses: a pilot RCT.

OBJECTIVE: To compare framework passive fit, subjective evaluations, and short-term clinical outcomes between conventional impressions (CI) and intraoral scanning (IOS) for complete-arch implant-supported fixed dental prostheses (CIFDPs). METHODS: In this randomized controlled trial, 22 patients were allocated to the CI or IOS groups. All participants received a definitive one-piece CIFDP. The primary outcome was framework passive fit, assessed using the Vision and Tactile Score (V&T score), which included framework lift-off, the single-screw test, the full-screw test, smoothness of screw insertion, and radiographic gap assessment. Secondary outcomes included operator evaluation, patient satisfaction using a visual analog scale (VAS), early implant survival, marginal bone loss (MBL), modified Plaque Index (mPII), and complications at the 6-month follow-up. RESULTS: Twenty-two patients were enrolled (CI: n = 11; IOS: n = 11), and one patient in the CI group was lost to follow-up. No statistically significant difference in the V&T score was observed between the CI and IOS groups (4.66 &#xb1; 0.17 vs. 4.65 &#xb1; 0.28; P = 0.93). The operator reported greater nervousness during the CI procedure than during IOS (21.82 &#xb1; 15.69 vs. 8.64 &#xb1; 7.47; P < 0.05). Patients in the CI group reported significantly greater discomfort, including nausea and anxiety, than those in the IOS group (P < 0.05). At the 6-month follow-up, the early implant survival rate was 100% in both groups. No significant differences were found between the groups in MBL (0.09 &#xb1; 0.09 vs. 0.06 &#xb1; 0.10 mm; P = 0.43) or mPII (0.10 &#xb1; 0.12 vs. 0.10 &#xb1; 0.28; P = 0.99). CONCLUSION: IOS and CI achieved comparable short-term clinical outcomes in patients who met the predefined inclusion criteria, including controlled implant number, spacing, and angulation. IOS provided a more favorable experience for both operators and patients. CLINICAL SIGNIFICANCE: In complete-arch implant restorations, intraoral scanning may provide clinical outcomes comparable to those of conventional impressions while improving patient comfort.

Humans