Search PubMedSearch

SEARCH · Search PubMed

Results for “Standard error of measurement”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

2,992 records · Page 3Linked to original sources

Perioperative safety and survival outcomes of robot-assisted partial nephrectomy in elderly patients with localized renal cell carcinoma: an overlap-weighted Asian cohort study.

The value of robot-assisted partial nephrectomy (RAPN) in elderly Asian patients with localized renal cell carcinoma (RCC) remains insufficiently defined. We retrospectively analyzed 339 patients (&#x2265;&#x2009;70 years) with localized RCC treated at a single Asian center between 2015 and 2025, including 119 undergoing partial nephrectomy (PN) and 220 undergoing radical nephrectomy (RN). Propensity score overlap weighting (OW) was applied to compare PN versus RN and, within the PN cohort, RAPN versus laparoscopic partial nephrectomy (LPN). Three open partial nephrectomy cases were summarized descriptively and retained only in exploratory sensitivity analyses. Weighted logistic regression and Cox models with robust standard errors evaluated Clavien-Dindo grade&#x2009;&#x2265;&#x2009;II complications and overall survival (OS). After OW, PN was associated with better early postoperative renal functional preservation than RN but a greater incidence of grade&#x2009;&#x2265;&#x2009;II complications (36.4% vs. 17.6%; weighted p&#x2009;<&#x2009;0.001); OS was similar. Within the PN cohort, RAPN had longer operative time than LPN (weighted p&#x2009;=&#x2009;0.030), whereas warm ischemia time, early postoperative eGFR, and grade&#x2009;&#x2265;&#x2009;II complications (31.8% vs. 40.4%; weighted p&#x2009;=&#x2009;0.414) were not significantly different. Exploratory analyses favored RAPN, but only one death occurred in this group, and residual confounding remains possible. PN may preserve early renal function in selected older patients, while RAPN appears feasible in experienced centers; its survival association remains hypothesis-generating.

Humans

Analyzing salinity tolerance in grass carp (Ctenopharyngodon idella): Insights from genome-wide association study and genomic selection.

Grass carp (Ctenopharyngodon idella) is one of the most widely cultured freshwater fish species globally. However, the expansion of its farming scale faces severe limitation owing to freshwater scarcity; therefore, the development of strains with greater salinity tolerance is key for expanding production using brackish water resources. To investigate the genetic basis of salinity tolerance in grass carp, a genome-wide association study (GWAS) was conducted using 200 individuals representing extreme phenotypes, namely salinity-tolerant and salinity-sensitive groups. In total, 17 single nucleotide polymorphisms (SNPs) related to salinity tolerance were detected, which were distributed across 11 chromosomes. Through gene annotation, 38 candidate genes were obtained from these loci. Enrichment analysis revealed these candidate genes are primarily implicated in key biological processes, including osmotic regulation, energy metabolism, and stress responses. Analyses of different SNP densities revealed that the 5&#xa0;K SNP density panel can balance prediction accuracy and computational efficiency. The BayesA model achieved the highest prediction accuracy under the GWAS_Evenly selection strategy, with substantial reductions in mean absolute error and mean square error. This study reveals the genetic mechanisms of salinity tolerance in grass carp, which might be optimized through genomic selection, and provides insights for selectively breeding new varieties with greater salinity tolerance.

Animals

A Standardized Nursing-Led Protocol Integrated Pain, Sleep, Medication Adherence, and Symptom Management in Postherpetic Neuralgia.

Postherpetic neuralgia (PHN) is a persistent neuropathic pain condition after herpes zoster that frequently coexists with sleep disturbance, medication-related problems, and fluctuating symptoms. This study evaluated whether a standardized nursing-led protocol could improve multidimensional short-term outcomes beyond usual care. In this prospective, parallel-group randomized controlled trial, 128 adults with PHN were allocated 1:1 to usual care or usual care plus an eight-week protocol integrating structured pain assessment, sleep monitoring, medication-adherence support, and rule-based digital symptom monitoring. The primary outcome was the between-group difference in change in Numeric Rating Scale (NRS) pain score from baseline to Week 8. Secondary outcomes included Pittsburgh Sleep Quality Index (PSQI), MMAS-8 medication adherence, symptom burden, pain-related nocturnal awakenings, breakthrough pain, rescue analgesic use, adverse events, rule-based alerts, and nursing satisfaction. Week-8 data were available for 116 participants (57 usual care; 59 protocol). Mean NRS scores decreased from 7.19 &#xb1; 1.08 to 4.82 &#xb1; 1.53 in the usual-care group and from 7.28 &#xb1; 1.05 to 3.24 &#xb1; 1.28 in the protocol group. An NRS reduction of at least 2 points occurred in 49.1% and 76.3% of participants, respectively. The protocol group also showed larger improvements in PSQI, MMAS-8, symptom burden, and nocturnal awakenings, with fewer breakthrough-pain episodes and less rescue-analgesic use. These findings support further evaluation of the standardized nursing-led protocol in preregistered multicenter trials with intention-to-treat analyses and longer follow-up.

Humans

Not just when, but how: An exploratory dual-control approach to video feedback in motor learning.

The present study provides exploratory evidence for a novel dual-control paradigm. It examines whether combining temporal over video feedback timing with learner-controlled interactive playback functions (pause, slow-motion, rewind) would enhance motor skill acquisition beyond temporal autonomy alone. Sixty-four novice adults were randomly assigned to one of four conditions: Full Control (self-controlled timing + interactive replay), Partial Control (self-controlled timing + non-interactive replay), Yoked Full Control (externally controlled timing + interactive replay), or Yoked Partial Control (externally controlled timing + non-interactive replay). Motor accuracy (Radial Error), movement consistency (Bivariate Variable Error), technical execution, and self-efficacy were assessed at pre-test, 24-h retention, and 72-h retention following two acquisition sessions on a dart-throwing task (120 trials total). The Full Control group demonstrated the greatest and most durable learning gains across all outcomes. The Group &#xd7; Time interaction was significant across all dependent variables (&#x3b7;2&#x209a; ranging from 0.140 to 0.234), with Full Control demonstrating superior retention at both 24 and 72&#xa0;h relative to other groups (though differences relative to Partial Control were more pronounced at 72-h retention). Critically, the Yoked Full Control group showed comparatively weaker outcomes despite access to the same interactive playback functions. These findings suggest that interactive video tools may be most useful when learners can regulate both when feedback is accessed and how it is inspected. Theoretical and practical implications for the design of learner-centered video feedback systems are discussed.

Humans

Improving insurance deduction identification: a hybrid artificial intelligence model using machine learning and expert systems.

PURPOSE: Financial challenges in healthcare systems worldwide, especially in low- and middle-income countries like Iran, have increased hospitals' reliance on insurance reimbursements. Unrecognized insurance deductions often cause severe financial shortages, making efficient deduction management crucial. This study aimed to design a hybrid intelligent system for identifying and predicting insurance deductions by combining machine learning and expert system frameworks. DESIGN/METHODOLOGY/APPROACH: A mixed-methods design was applied in four stages. First, a scoping review identified the causes and patterns of insurance deductions. Second, interviews with 15 insurance experts produced a validated checklist and a dataset from inpatient billing records. Third, using the CRISP-DM methodology, machine learning algorithms were developed and tested in SPSS Modeler alongside a fuzzy expert system developed in MATLAB. Finally, the model was validated using the holdout method. FINDINGS: Four categories of deduction drivers were identified: service provision, registration errors, document submission issues, and revenue conversion processes. The CHAID decision tree outperformed other algorithms with a 99% precision rate and the lowest Mean Absolute Error (9.43). A brief assessment of potential overfitting was conducted to ensure that the CHAID model's high accuracy was interpreted cautiously and supported by the validation results. The fuzzy expert system with validated rules was adaptable for deduction classification, especially for cases unsuitable for quantitative modeling. ORIGINALITY/VALUE: The hybrid model improves detection and prevention of deductions, offering actionable insights for hospital administrators, insurers, and policymakers. Its implementation can enhance hospital information systems, streamline claims processing, and optimize revenue management amid financial constraints.

Machine Learning

Plasma proteomics: considerations for preanalytical variability; a systematic review with narrative synthesis.

BACKGROUND: The plasma proteome (PP) is a dynamic system subject to pathology-associated changes and a focus for novel disease biomarker discovery. Disease-related PP research assumes protein concentrations in test specimens accurately reflect the in&#xa0;vivo milieu. However, measures to maintain the physicochemical integrity of the proteome before assay are often rudimentary, poorly described, or lacking standardisation in published studies. Contrastingly, in laboratory medicine, there is an expectation that errors in the so-called "preanalytical phase" (PAP) that impact patient results are understood, monitored, and mitigated against, while also being well described in research publications. There is therefore scope for good practice from laboratory medicine to inform PP research workflows. This review considers factors in the PAP which may impact the validity of PP results. CONTENT: A systematic review was conducted per PRISMA guidelines, limited to English-language peer-reviewed studies (2014-2024). Candidate studies were imported, screened, and managed using Covidence systematic review software. SUMMARY: 15 eligible studies were reviewed, covering many relevant processes. 11 studies reported statistically significant differences in PP due to factors in the PAP. Temperature and time-to-processing were the most commonly reported factors affecting the PP, with significant effects reported in 8 studies. OUTLOOK: PAP variability can significantly affect results in PP studies. Careful consideration of the effect of each stage of the PAP is needed when working with the PP. In multicenter studies, pre-defined and research question-specific sample processing workflows are essential for reducing PAP variability, which helps ensure the validity of PP studies.

Humans

Patient-reported outcomes in pediatric regional anesthesia trials: current use and limitations.

PURPOSE OF REVIEW: This review examines the current use and limitations of patient-reported outcome measures (PROMs) in pediatric regional anesthesia research. Despite the increasing emphasis on patient-centered outcomes, existing pediatric outcome assessment frameworks may inadequately capture the pain experience and interference with daily living. RECENT FINDINGS: Across 17 identified randomized controlled trials and 15 ongoing studies, PROM use remains highly variable, with consistent reliance on observational pain scales such as the Face, Legs, Activity, Cry, and Consolability scale and limited incorporation of standardized, longitudinal health-related quality-of-life measures. SUMMARY: Current pediatric PROM frameworks remain fragmented, limiting comprehensive evaluation of recovery. Greater standardization and incorporation of developmentally appropriate, longitudinal outcome measures are needed to better align clinical research with meaningful patient-centered endpoints and to improve assessment of functional and psychosocial recovery.

Humans

Immersive virtual reality-assisted anatomy training improves endotracheal intubation performance in simulation: a randomized controlled trial among Chinese non-anesthesiology residents.

INTRODUCTION: This study aimed to compare immersive virtual reality (IVR)-assisted versus conventional anatomy training for teaching endotracheal intubation (ETI) to novice non-anesthesiology residents enrolled in China's Standardized Residency Training program. METHODS: A total of 90 non-anesthesiology residents without prior ETI experience were randomly assigned to either an IVR group receiving IVR-assisted anatomy training (n&#x2009;=&#x2009;45) or a control group receiving conventional anatomy training (n&#x2009;=&#x2009;45). All participants underwent a standardized teaching protocol. The primary endpoint was residents' ETI performance on a simulator, assessed using both the Global Rating Scale (GRS) and a task-specific checklist. The secondary endpoints included changes in written multiple-choice question (MCQ) scores and residents' evaluations of the course. RESULTS: In practical ETI assessments on a manikin, the IVR group achieved significantly higher scores on the task-specific checklist than the control group (90.34&#x2009;&#xb1;&#x2009;2.89 vs. 87.20&#x2009;&#xb1;&#x2009;3.29; p&#x2009;<&#x2009;0.001), whereas GRS scores were comparable between groups. Both groups showed significant post-training improvement in knowledge scores (p&#x2009;<&#x2009;0.001), with the IVR group showing a greater gain in theoretical knowledge (54.0% vs. 36.3%; p&#x2009;<&#x2009;0.001). Participants in the IVR group also expressed a stronger preference for their training method (80.8%) and reported higher levels of motivation, confidence, and enjoyment (all p&#x2009;<&#x2009;0.05). CONCLUSION: IVR-assisted anatomy training enhances the effectiveness of ETI training for novice non-anesthesiology residents, offering an interactive, engaging, and reproducible approach within China's Standardized Residency Training framework.

Humans

Comparative Evaluation of Virtual Reality versus Standard Nursing Care in Managing Pain and Fear during Lumbar Puncture Procedures: A Randomised Controlled Trial.

BACKGROUND: Meningitis is a serious infectious disease that can cause significant morbidity and long-term neurological problems. Although a lumbar puncture is a necessary diagnostic procedure, it is often accompanied by discomfort, anxiety, and fear, which can severely impact the patient's experience. Although there is few data on its application prior to lumbar puncture in adult patients with meningitis, immersive virtual reality (VR) has become a promising non-pharmacological technique for lowering procedural distress. Thus, among individuals undergoing lumbar punctures, this randomized controlled research assessed how well pre-procedural VR reduced pain, anxiety, and fear while enhancing patient satisfaction. OBJECTIVE: This study aims to evaluate the effectiveness of virtual reality (VR) in reducing pain and fear among adults undergoing lumbar puncture (LP) compared with standard care protocol. METHODS: A randomised clinical trial was conducted from May to October 2025, using a single-blind, true experimental design. A total of 85 patients were randomly assigned to either the VR intervention group ( n = 41) or the control group receiving standard care ( n = 44). Pain levels were assessed using a visual analogue scale. Fear was assessed using the Multidimensional Fear-of-Injection Scale. Data were analysed using SPSS version 26. RESULTS: According to the study, the findings revealed a significant reduction in pain levels among the study group following the VR intervention, with mean pain scores dropping from 7.54 &#xb1; 1.925 to 2.49 &#xb1; 0.675. In contrast, the control group showed increased pain intensity, with mean scores rising from 6.84 &#xb1; 1.842 to 8.36 &#xb1; 1.348. The VR group showed a significant reduction in fear scores across all domains, whereas no significant changes were observed in the control group. Direct fear decreased from 20.12 &#xb1; 1.71 to 9.44 &#xb1; 2.00, indirect fear from 17.24 &#xb1; 1.46 to 8.66 &#xb1; 2.24, physiological response improved from 0.34 &#xb1; 0.66 to 3.00 &#xb1; 1.00 and avoidance behaviour decreased from 16.71 &#xb1; 1.49 to 7.80 &#xb1; 1.85. CONCLUSIONS: The research shows that the use of VR prior to LP significantly reduces level of pain and fear compared to standard care. These results support VR as a non-pharmacological intervention for fear and pain to improve patient experience during invasive procedures. In contrast, the control group experienced no improvement.Trial Registration: The IRCT code for the trial was IRCT ID 20250803066743N1.

Humans

A framework for delivering real-time, instrument-relative navigation in transoral robotic surgery.

Transoral robotic surgery (TORS) is a minimally invasive, inside-out technique that, compared with traditional open approaches, provides fewer post-operative complications, shorter hospital stays, and improved survival for early-stage head and neck cancer. However, TORS is limited by its steep learning curve and poor visualization of deep tumor margins. This randomized crossover study evaluated a surgical navigation system's potential to enhance accuracy and user experience with real-time, instrument-relative feedback. Seven Teflon beads (d&#x2009;=&#x2009;2.381&#xa0;mm) were embedded at the tongue base of a porcine pharynx-and-larynx model. Tongue blade compression and retraction were applied to the model to mimic intraoperative tissue deformation, reproducing the anatomical shifts that occur relative to preoperative imaging. Eight participants used the da Vinci Surgical system to localize the beads by placing pins under two conditions: (a) preoperative computed tomography with no navigation; (b) model-based visual navigation with quantitative instrument-to-target metrics. Surgical accuracy was determined by calculating the target localization error (TLE, pin-to-bead Euclidean distance) and the angular error (AE, pin axis trajectory to bead). Accounting for training level and bead depth, surgical navigation reduced TLE by 5.44&#xa0;mm (95% CI, 4.02-6.86&#xa0;mm; p&#x2009;=&#x2009;2.00e-11) and AE by 8.47 degrees (95% CI, 6.21-10.72 degrees; p&#x2009;=&#x2009;5.17e-11). Impressions of the system were generally favorable using a 5-point Likert survey and task duration (p&#x2009;=&#x2009;0.26) or cognitive workload via the NASA-Task Load Index (p&#x2009;=&#x2009;0.22) were not significantly affected. The navigation system demonstrated translational promise, offering improved target localization accuracy and more consistent performance across experience levels, two critical determinants of surgical quality in TORS.

Robotic Surgical Procedures

Comparison between measured and synthesized posterior lead electrocardiograms during percutaneous coronary intervention-induced myocardial ischemia.

BACKGROUND: Posterior/inferolateral myocardial ischemia is frequently underrecognized on standard 12&#x2011;lead electrocardiography (ECG). Synthesized posterior leads derived from the standard 12&#x2011;lead ECG have been proposed as an alternative to directly measured posterior leads; however, their accuracy under controlled ischemic conditions has not been fully validated. METHODS: We prospectively enrolled 26 consecutive patients undergoing percutaneous coronary intervention (PCI) in whom simultaneously recorded measured and synthesized posterior lead ECGs (V7-V9) were obtained during balloon-induced myocardial ischemia. ST-segment deviation was measured at the ST junction (STJ), 40&#xa0;ms (ST1), and 80&#xa0;ms (ST2) thereafter. Agreement between measured and synthesized posterior leads was assessed using Pearson correlation and Bland-Altman analyses. As an exploratory patient-level analysis, diagnostic performance was compared with reciprocal anterior ST-segment depression (V1-V4). RESULTS: Strong correlations were observed between measured and synthesized posterior lead ST-segment deviations (V7: r&#xa0;=&#xa0;0.89; V8: r&#xa0;=&#xa0;0.86; V9: r&#xa0;=&#xa0;0.83; all P&#xa0;<&#xa0;0.001). Bland-Altman analysis demonstrated minimal systematic bias (within &#xb1;0.004&#xa0;mV) and narrow limits of agreement. Synthesized posterior leads showed higher diagnostic performance than reciprocal anterior ST-segment depression (AUC 0.917 vs. 0.708), although the difference was not statistically significant (DeLong test, P&#xa0;=&#xa0;0.197). Using a 0.05&#xa0;mV threshold, synthesized posterior leads demonstrated 83.3% sensitivity, 100% specificity, and 96.2% overall accuracy. CONCLUSIONS: Synthesized posterior leads closely reproduced measured posterior lead ST-segment deviations during percutaneous coronary intervention (PCI)-induced myocardial ischemia, supporting the technical validity of posterior lead reconstruction. Larger prospective studies are warranted to determine whether synthesized posterior leads provide incremental diagnostic value beyond careful interpretation of the standard 12&#x2011;lead ECG.

Humans

Robotic Needle Insertion for CT-guided Percutaneous Biopsy of Thoracoabdominal Lesions: A Prospective Multicenter Randomized Trial.

Purpose To compare safety and feasibility between a novel CT-guided robotic system and the conventional freehand technique for puncture biopsy of thoracoabdominal lesions. Materials and Methods In this prospective multicenter randomized trial, individuals with suspected lesions were enrolled between July 2023 and April 2024 across three university teaching hospitals and randomized to the robot-assisted group (n = 82) or the freehand group (n = 83). Procedure outcomes included the technical success rate, targeting error, number of CT scans and needle adjustments, puncture time, and complications. Descriptive and inferential statistics were calculated. Results A total of 165 participants (mean age, 60 years &#xb1; 10 [SD]; 83 male) were included. Compared with the freehand group, the robot-assisted group demonstrated a higher technical success rate (97.56% [80 of 82] vs 62.65% [52 of 83], P < .001), lower targeting error (mean Euclidean deviation: 1.7 mm &#xb1; 1.1 vs 4.5 mm &#xb1; 3.9, P < .001), and fewer CT scans (mean, 4.3 &#xb1; 1.9 vs 5.2 &#xb1; 2.3; P = .002) and needle adjustments (mean, 0.7 &#xb1; 0.7 vs 1.6 &#xb1; 1.6; P = .003). Despite differences in geometric precision, both groups achieved 100% (82 of 82 and 83 of 83) diagnostic yield. The median puncture time was comparable between groups (5.5 minutes &#xb1; 4.3 vs 4.8 minutes &#xb1; 7.0, P = .50). During lung biopsies, the robot-assisted approach yielded fewer complications compared with the freehand approach (4.88% [four of 82] vs 16.87% [14 of 83], P = .014). Conclusion Compared with the freehand approach, robot-assisted biopsy yielded greater precision and reduced adjustments and complications while demonstrating noninferior diagnostic efficacy and comparable duration. Keywords: Robotic Needle Insertion, Biopsy, Thoracoabdominal Lesions, Robot-assisted Biopsy, CT-guided Intervention, Percutaneous Needle Biopsy, Randomized Controlled Trial, Algorithm Development, CT, Clinical Testing, Interventional-Body, Biopsy/Needle Aspiration, Percutaneous, Thorax, Abdomen/GI, Liver, Lung, Kidney &#xa9;RSNA, 2026.

Humans

Proficiency-based training and evidence-based methodology: a systematic review and meta-analysis.

OBJECTIVE: To assess adherence of self-labelled proficiency-based progression (PBP) studies to evidence-based PBP criteria and examine associations with training outcomes. METHODS: A systematic review and meta-analysis were conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines and registered in the International Prospective Register of Systematic Reviews. PubMed, CENTRAL, EMBASE, MEDLINE, and Scopus were searched from inception to 1 March 2023. Prospective English-language studies on healthcare procedural training reporting objective performance outcomes were included; non-prospective, non-quantitative, non-procedural, non-English studies, and reviews were excluded. Pre-specified outcomes included adherence to 18 evidence-based PBP criteria and objective performance metrics (errors, steps, time); secondary outcomes included proficiency benchmark achievement and Likert ratings. Data extraction was performed independently by multiple reviewers. Study quality was assessed using the Medical Education Research Study Quality Instrument and risk of bias by two investigators. Effect sizes were pooled using random-effects models (DerSimonian-Laird), expressed as the ratio of means (ROM) for continuous outcomes and bias-corrected odds ratios for dichotomous outcomes. RESULTS: Of 646 studies identified 175 met inclusion criteria. In the PBP studies (n&#x2009;=&#x2009;18), 94% fulfilled minimum criteria (use of a proficiency benchmark, its quantitative definition, and requirement for demonstration prior to progression) vs 36% of non-PBP studies (n&#x2009;=&#x2009;157). If all PBP criteria were included, 83% of PBP studies used these criteria vs only 2% of non-PBP-studies. In quantitative analysis (27 randomised clinical studies, 761 participants), ROM results showed that PBP training reduced the number of performance errors by 58% (P&#x2009;<&#x2009;0.001) and procedural time by 28% (P&#x2009;=&#x2009;0.006), increasing number of steps performed by 22% (P&#x2009;=&#x2009;0.03). When stratified based on number of criteria fulfilled, meta-regression demonstrated that increasing the number of PBP criteria fulfilled was associated with progressive and systematic trainee performance improvement. CONCLUSIONS: The more training methodologies adhere to established PBP criteria, the better training outcome will be.

Humans

Nociception-guided opioid administration within multimodal analgesia for laparoscopic endometriosis surgery: a randomized controlled trial.

Women with endometriosis are at increased risk of severe postoperative pain due to nociceptive sensitization. While multimodal analgesia reduces opioid use, the added value of objective nociception monitoring remains unclear. This study evaluated whether NOL&#xae;-guided opioid titration improves perioperative outcomes within a standardized multimodal regimen. In this prospective, randomized, single-blinded trial, premenopausal women undergoing laparoscopic surgery for suspected endometriosis or adenomyosis were assigned to NOL&#xae;-guided analgesia or standard care based on clinical assessment. All patients received a standardized multimodal protocol. The primary outcome was total perioperative opioid consumption. Secondary outcomes included postoperative pain scores (NRS) and PACU length of stay. Exploratory analyses assessed the association between preoperative pain (Mankoski Pain Scale, MPS) and postoperative outcomes. A total of 111 patients were analyzed (NOL&#xae;: n&#x2009;=&#x2009;54; control: n&#x2009;=&#x2009;57). Total perioperative opioid consumption did not differ significantly between groups (adjusted mean difference&#x2009;=&#x2009;14&#xa0;&#x3bc;g for Fentanyl and 52&#xa0;&#x3bc;g for Remifentanil; p&#x2009;=&#x2009;0.8). Surgery duration was an independent predictor of opioid use (p&#x2009;<&#x2009;0.001) and PACU length of stay (p&#x2009;=&#x2009;0.01), whereas treatment group had no significant effect. Postoperative pain scores were comparable between groups at all time points. NOL&#xae;-derived metrics were not associated with opioid consumption or pain. Higher preoperative MPS scores independently predicted higher pain scores in the late PACU phase. NOL&#xae;-guided opioid titration did not reduce perioperative opioid consumption or improve early postoperative outcomes compared with standard multimodal analgesia in women undergoing laparoscopic surgery for endometriosis.

Humans

Measurement of low-density lipoprotein cholesterol and other circulating lipids in Brazil: a systematic literature review.

Accurate laboratory assessment of circulating lipids underpins cardiovascular risk stratification, yet clinical interpretation depends not only on the assays but on the formula chosen to estimate low-density lipoprotein cholesterol (LDL-C). This review integrates the 2019-2025 evidence on laboratory methods for triglycerides (TG), total cholesterol (TC), and high-density lipoprotein cholesterol (HDLC), and on the formulas estimating LDL-C, VLDL-C, and non-HDL cholesterol, to determine how these should be measured, reported, and harmonized in Brazil, where lipid thresholds are adapted from international consensus. A PRISMA 2020 systematic search (PROSPERO CRD420251241064) of PubMed/MEDLINE, Scopus, SciELO, LILACS, Web of Science, and Embase retrieved 57,915 records; after removing 38,210 duplicates, 19,705 titles/abstracts were screened, 312 full texts assessed, and 25 sources included. Enzymatic colorimetric assays remain standard for TG, TC, and HDLC. For LDL-C, Martin/Hopkins classifies more accurately than Friedewald (89.6% vs 83.2% correct categorization in 5,051,467 patients), particularly at high TG and low LDL-C, while Sampson/NIH and modified Sampson/NIH extend reliable estimation into hypertriglyceridemia and very low LDL-C; direct measurement is reserved for TG beyond the validated range. Although the review centers on the Friedewald, Martin/Hopkins, and Sampson/NIH families that dominate guideline practice, other published equations exist and are addressed in context. In Brazil, atherogenic-lipid thresholds are risk-based decision limits rather than reference intervals; national surveys describe lipid distributions but were not designed to establish them. Analytical standardization through traceability programs, multicenter validation of formulas, and-where the distribution-based construct applies (HDLC, pediatrics)-nationally derived reference intervals are priorities for equitable cardiovascular risk assessment in Brazil.

Humans

GATA2 deficiency: enhancer deregulation, immune surveillance failure, and clonal evolution.

Germline mutations in GATA2 cause a syndromic inborn error of immunity characterized by cytopenia, infections, immune dysregulation, and a marked predisposition to myelodysplastic syndrome and acute myeloid leukemia. Initially defined by the DCML phenotype-dendritic cell, monocyte, B- and NK-cell deficiency-GATA2 deficiency is now recognized as a disorder of global immune-hematopoietic homeostasis. Recent multi-omics and experimental models reveal enhancer-driven inflammatory rewiring, IRF8-dependent lineage imbalance, and premature hematopoietic aging. In parallel, adaptive immune defects, including impaired B- and T-cell development and function, contribute to defective immune surveillance. These alterations not only explain susceptibility to infection but also shape clonal evolution and malignant transformation. Clinically, improved risk stratification and transplant outcomes underscore the importance of early recognition and monitoring of immune dysfunction. GATA2 deficiency thus represents a paradigm linking immune dysregulation, inflammatory stress, and cancer predisposition.

Humans

Cochlear size variation in a large-scale international multicentre cohort.

AIM: This study aims to (1) review the literature on cochlear size, measured by the A-value, to assess reported variation across studies, and (2) consolidate cochlear parameters-specifically basal turn diameter (A-value) and width (B-value)-measured using the standardized DICOM viewer OTOPLAN&#xae;, and compare these with published data. METHODS: A scoping literature review was conducted using the search term "diameter of cochlear basal turn" to identify studies reporting A-value measurements. To complement this, cochlear measurements obtained with OTOPLAN&#xae; were collected from clinical collaborators across multiple international centres. The ratio of B- to A-values, which defines the cochlear basal turn shape, was calculated as previously described by Khurayzi et al. (2021). RESULTS: The literature review identified 38 studies comprising 5,206 A-value measurements (average: 9.08 mm; range: 8.01-10.03 mm). Additionally, 5,580 OTOPLAN&#xae; measurements were collected from 43 clinics across 25 countries (mean: 9.07 mm; range: 6.67-11.45 mm). Overall, 68.7% of cochleae exhibited an elliptical basal turn shape. CONCLUSION: Using a large, international multicentre dataset and a standardized measurement tool, this study demonstrates substantial variation in cochlear size and shape across clinical cohorts from different regions. The mean A-value (9.07 mm) is consistent with previously published literature, while the wider observed range highlights greater anatomical variability within a multicentre clinical population than previously reported. The majority of cochleae demonstrate an elliptical basal turn configuration.

Humans

Socket motility assessment of anophthalmic sockets: a systematic review.

PURPOSE: Systematically review and categorize the methods used to assess socket and prosthetic motility in anophthalmic patients following enucleation or evisceration. METHODS: A systematic review was conducted in accordance with PRISMA guidelines. PubMed, Embase, Web of Science, and Scopus were searched from inception through September 2024. Studies reporting qualitative or quantitative assessments of motility in anophthalmic sockets or ocular prostheses were included. Motility assessment methods were categorized as qualitative (descriptive or graded clinical evaluation) or quantitative (numerical measurements in millimeters, degrees, or objective tracking systems). RESULTS: Thirty-five studies encompassing 1,819 patients met inclusion criteria. Nineteen studies used qualitative assessment methods, including subjective observation, graded scales based on cardinal gaze positions, or comparison with the contralateral eye. Sixteen studies employed quantitative techniques, such as the Kestenbaum limbus test, Lister perimeter measurements, conjunctival or limbal markings, photographic image analysis, infrared eye-tracking systems, and magnetic search-coil technology. Considerable heterogeneity was observed in measurement techniques, reporting standards, timing of assessment, and distinction between socket and prosthetic motility. CONCLUSIONS: Substantial variability exists in the methods used to assess motility in anophthalmic sockets, limiting comparability across studies. Establishing standardized, feasible, and reproducible assessment approaches may improve outcome reporting and facilitate meaningful comparisons in future oculoplastic research.

Humans