Search PubMedSearch

SEARCH · Search PubMed

Results for “anal barrier device”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

200 records · Page 2Linked to original sources

Analyzing the impact of subcutaneous injection needle, device, and administration characteristics on patient pain, anxiety, and safety: a systematic literature review.

The subcutaneous (SC) injection route is a commonly used and important method for therapeutic delivery of a wide range of compounds, and needle characteristics have a significant influence on patient pain, anxiety, safety, and other outcomes. This systematic review evaluates the evidence on how needle-specific characteristics (e.g. gauge, length, tip design, wall thickness, concealment) and administration- or device-related factors can affect patient-reported outcomes and clinical safety indicators during and following SC injections. A comprehensive search was conducted in MEDLINE, PubMed, Embase, and ClinicalTrials.gov in June 2024. Studies were included if they assessed the relationship between needle characteristics and pain, anxiety, safety, or related outcomes in individuals receiving SC injections. A dual-reviewer process was used for study selection, data extraction, and quality assessment. Sixty-two studies met inclusion criteria. Evidence consistently indicated that thinner and shorter needles reduced patient-reported pain and adverse events such as bruising and bleeding. Tapered and lubricated needles, hidden or retractable needle designs, and use of autoinjectors or prefilled syringes also contributed to reduced anxiety and improved user satisfaction. However, results were heterogeneous, and many studies lacked sufficient power or single-variable evaluation of individual needle parameters, limiting definitive conclusions. Needle characteristics significantly influence patient experience and safety with SC delivery. While both clinical evidence and practical experience clearly favor thinner, shorter, and concealed needles, further standardized, high-quality research is needed to isolate and quantify the specific contributions of individual needle characteristics to optimize injection practices and support patient-centered device design.

Humans

Improving Patient Comfort of Vibratory Anesthetic Devices With a Dampener: A Pilot Study.

BACKGROUND: Vibratory anesthetic devices (VADs) reduce dermatologic injection pain, but their vibration can feel harsh at sensitive anatomical sites. Simple modifications improving patient comfort may enhance VAD adoption. OBJECTIVE: The authors evaluated whether dampening VAD vibration with a cotton buffer improves patient comfort and characterized tactile features influencing preferences. MATERIALS AND METHODS: In a single-site, participant-blinded pilot study (N = 53), adults received a dampened VAD (D-VAD) and standard VAD (S-VAD) at 5 sites-lateral nasal wall, submalar cheek, ear helix, lateral neck, and dorsal forearm-in randomized, contralateral application. Site-specific preference was analyzed with binomial and Cochran Q tests; demographic associations with univariate analyses. Word2vec and hierarchical clustering analyzed qualitative reasons behind patient preference. RESULTS: D-VAD was preferred at all sites across demographics-lateral nasal wall (88.7%), submalar cheek (84.9%), ear helix (88.7%), lateral neck (77.4%), and dorsal forearm (75.5%) (all p < .001), with strongest preference at face and head/neck (p = .018). Computational semantics analysis of qualitative responses identified 6 themes driving preference: Smoothness, Gentleness, Controlled, Low Frequency, Low Intensity, and Less Bothersome. CONCLUSION: Dampening VAD vibration with a cotton buffer enhances comfort across sensitive sites, with reduced harshness and smoother sensation underlying preference. This simple modification may improve patient experience, encouraging broader VAD adoption.

Humans

Glaucoma filtering surgery combined with phacoemulsification in the era of new aqueous humor filtration devices: A systematic review.

We evaluate the efficacy and safety of filtering glaucoma surgeries combined with phacoemulsification (PCE)-including new aqueous humor drainage devices-compared to standalone procedures. We performed a systematic search up to March 23, 2025, including all comparative studies assessing trabeculectomy (TRAB), non-penetrating deep sclerectomy (NPDS), Xen&#xae; Gel Stent (XEN), or Preserflo&#xae; MicroShunt (PMS) combined with PCE, versus the same surgery alone. Key exclusion criteria include inadequate follow-up (less than 12-month), absence of a defined success criterion, more than 50% of loss to follow-up at 12-month, and lens extraction performed without PCE. Main outcome was surgical success at &#x2265;&#x202f;12 months. Secondary outcomes included intraocular pressure (IOP) reduction, decrease in hypotensive medications, and rates of complications. A total of 27 studies were included for analysis. Among studies comparing TRAB/PCE with standalone TRAB, half reported similar success rates, while others favored standalone TRAB, particularly using strict IOP thresholds. Safety profiles were comparable. For NPDS/PCE, data mostly showed equivalent outcomes versus standalone NPDS, with comparable safety. In studies on XEN/PCE and PMS/PCE, results suggested similar rates of surgical success, efficacy in IOP and medication reduction, and safety compared to their stand-alone procedures. Small differences occasionally favored standalone procedures under stricter success definitions. Current evidence suggests that combined filtering glaucoma surgery provides long-term efficacy and safety comparable to standalone, though some subgroups and outcome thresholds may slightly favor standalone approaches. The limited availability of high-quality prospective trials underscores the need for further large-scale robust studies.

Humans

Prostate morcellation devices: a systematic review and meta-analysis of clinical outcomes and efficiency.

OBJECTIVE: To systematically evaluate the efficiency and safety of different prostate morcellators used during prostate enucleation for benign prostatic hyperplasia (BPH). METHODS: A systematic review was performed according to the Preferred Reporting Items for Systematic Review and Meta-analyses guidelines. PubMed/Medline, Scopus, and Web of Science were searched for studies published between October 2012 and May 2025. Studies reporting clinical outcomes of morcellators used during prostate enucleation were included. Primary outcome was morcellation efficiency (g/min). Secondary outcomes included intraoperative complications, device malfunction, and cost when available. Risk of bias (RoB) was assessed using the Risk Of Bias In Non-randomised Studies of Interventions (ROBINS-I), RoB 2 tool, and European Association of Urology case-series criteria. Random-effects meta-analyses and multilevel meta-regression adjusted for prostate volume were conducted. RESULTS: A total of 22 studies comprising 5980 patients were included, most undergoing holmium laser enucleation of the prostate. The most frequently evaluated devices were the Piranha&#x2122; (Richard Wolf GmbH, Knittlingen, Germany) and Lumenis VersaCut&#x2122; (Lumenis Ltd., Yokneam, Israel; 12 and 13 studies, respectively), followed by DrillCut&#x2122; (Karl Storz SE & Co. KG, Tuttlingen, Germany), MultiCut&#x2122; (Asclepion Laser Technologies GmbH, Jena, Germany), and Cyber Blade&#x2122; (Quanta System SpA, Milan, Italy) systems. Unadjusted weighted mean morcellation efficiency was 7.80&#x2009;g/min (95% confidence interval [CI] 6.26-9.34&#x2009;g/min) for Piranha, 4.70&#x2009;g/min (95% CI 3.61-5.79&#x2009;g/min) for VersaCut, 5.90&#x2009;g/min (95% CI 3.16-8.64&#x2009;g/min) for DrillCut, and 9.59&#x2009;g/min (95% CI 4.78-14.39&#x2009;g/min) for MultiCut. In volume-adjusted meta-regression using Piranha as reference, VersaCut remained significantly less efficient (-2.75&#x2009;g/min; 95% CI -4.58 to -0.92&#x2009;g/min; P&#x2009;=&#x2009;0.003), with an even greater difference in prostates >70&#x2009;mL (-4.34&#x2009;g/min). Bladder mucosal injury was the most frequently reported complication; however, relatively rare across all devices. Meta-analysis demonstrated a significantly higher risk with VersaCut compared to Piranha (risk ratio 3.22, 95% CI 1.81-5.71), with low heterogeneity. CONCLUSION: This systematic review provides a contemporary clinical benchmark of the efficiency and safety of currently available prostate morcellators. Oscillating blade systems, particularly the Piranha morcellator, demonstrated higher morcellation efficiency and a more favourable safety profile than reciprocating blade devices, with the largest performance differences observed in patients with larger prostates.

Humans

Postoperative Curvature Loss in Three-Level Anterior Cervical Discectomy and Fusion With Zero-Profile Device.

PURPOSE: Cervical curvature loss is a frequent complication following 3-level anterior cervical discectomy and fusion (ACDF) using a Zero-Profile device. Consequently, the capacity of this device to maintain cervical sagittal alignment in 3-level ACDF remains highly controversial. This study aimed to identify potential predictors for postoperative curvature loss (PCL) and evaluate its impact on clinical outcomes. METHODS: A total of 113 patients who underwent ACDF for 3-level cervical degenerative disc disease (CDDD) between January 2021 and December 2023 were retrospectively reviewed. Demographic data, radiological parameters, and clinical outcomes were analyzed. Radiographic measures included cervical curvature, T1 slope, C2-7 sagittal vertical axis, and titanium plate and endplate (TPE) distance. Clinical outcomes were assessed using the Visual Analog Scale (VAS), Neck Disability Index (NDI), and Japanese Orthopaedic Association (JOA) scores. Statistical analyses were performed using paired and independent t-tests, as well as Pearson correlation coefficients. RESULTS: The average curvature loss was 6.82&#xb0; from 1&#x2009;week postoperatively to the final follow-up (p&#x2009;<&#x2009;0.001). However, the final curvature (11.65&#xb0;) was maintained, representing a 4.33&#xb0; improvement compared to preoperative values. Significant correlations were observed between PCL and preoperative curvature (r&#x2009;=&#x2009;-0.368, p&#x2009;=&#x2009;0.013), preoperative T1 slope (r&#x2009;=&#x2009;-0.546, p&#x2009;<&#x2009;0.001), &#x2206;T1 slope (r&#x2009;=&#x2009;0.443, p&#x2009;=&#x2009;0.002), and &#x2206;TPE distance (r&#x2009;=&#x2009;0.417, p&#x2009;=&#x2009;0.004). PCL did not correlate with Japanese Orthopaedic Association (JOA) scores or arm VAS scores at the final follow-up. Nevertheless, patients with a PCL&#x2009;&#x2265;&#x2009;6&#xb0; exhibited significantly higher neck VAS (p&#x2009;=&#x2009;0.028) and NDI scores (p&#x2009;=&#x2009;0.041). CONCLUSION: Although contiguous 3-level ACDF with a Zero-Profile device may result in PCL, it preserves an improved cervical lordosis compared to the preoperative baseline. Low preoperative curvature and a low preoperative T1 slope are potentially predictive factors for PCL. Postoperative changes in TPE distance and T1 slope are significantly associated with PCL, suggesting a potential biomechanical link that requires direct validation. Furthermore, PCL may lead to higher neck VAS and NDI scores. Consequently, the Zero-Profile device may require careful consideration in 3-level CDDD patients presenting with low preoperative curvature and a low T1 slope. Importantly, the 6&#xb0; PCL threshold identified is preliminary and requires prospective validation before clinical application.

Humans

Use of wearable technologies for physical activity promotion in older adults: A systematic review.

This systematic review, conducted according to PRISMA guidelines and registered in PROSPERO (CRD420251055299), examined the use of wearable technologies for promoting physical activity (PA) in adults aged 60 years and older. Searches across five databases (PubMed, Scopus, Web of Science, CINAHL, Cochrane) identified 2438 records, of which only six randomized controlled trials published between 2021 and 2025 met inclusion criteria, with sample sizes ranging from 36 to 551 participants and mean ages between 65 and 79 years. Given the small number of included studies, findings should be interpreted as preliminary. The studies ranged from the standalone use of commercial trackers (Fitbit, Polar, ActiGraph) to multicomponent interventions combining wearables with physiotherapist feedback, telephone counseling, web-based platforms, or interactive cognitive-motor training. Wearables used alone, as in the REACT trial, produced small or non-significant PA effects. In contrast, interventions integrating devices with personalized feedback, professional support, or digital platforms, such as PROMOTE and TASMANIA, were associated with more consistent improvements in PA, physical function, and cognitive outcomes. Multicomponent programs, such as PEER and ICMT, reported broader benefits, including cognition, balance, and reductions in sedentary behavior, though these findings derive from individual trials and require replication. Risk of bias, assessed with the Cochrane Risk of Bias tool version 2 (RoB 2.0), was rated as "some concerns" for five studies and low for only one, mainly due to gaps in randomization reporting, missing data, and lack of preregistration. Tentatively, and based on a very limited evidence base, wearables may have greater impact when embedded within broader behavioral systems, incorporating feedback, coaching, or interactive components, rather than when used in isolation as passive monitoring tools. Adherence and psychosocial outcomes appeared related to comfort and perceived usefulness among older adults, though larger and more robust trials are needed to confirm these patterns.

Humans

Reliability, Device Agreement and Validity of Load-Velocity Profiles: A Systematic Review with Meta-analysis.

BACKGROUND: For a valid one-repetition maximum (1RM) prediction via load-velocity (LV) relationships, high reliability and accuracy must be assumed. OBJECTIVE: Since individual study results indicate ambivalent prediction, this systematic review and meta-analysis was designed to provide a updated and comprehensive overview, extending knowledge about the validity and reliability of commercially available velocity sensors in Part I and the validity and reliability of velocity-based 1RM prediction models in Part II. METHODS: A systematic literature search was conducted in PubMed/MEDLINE, Web of Science, and Scopus. Validity and/or reliability studies or velocity-based 1RM prediction evaluations were included. Methodological quality was assessed using adapted COSMIN. The analysis was performed for intraclass correlation coefficient (ICC), Lin's concordance correlation coefficient (CCC), and Pearson's correlation coefficient (r). The review was preregistered in PROSPERO (CRD42025634595). RESULTS: Sixty-three studies were included for sensor validity and reliability and 38 for 1RM prediction models. Part I: Velocity sensors demonstrated good-to-excellent pooled validity and device agreement (ICC&#x2009;=&#x2009;0.91-0.92 [0.83-0.97]; k&#x2009;=&#x2009;55 and 439, respectively); intra- and inter-day reliability were classified as good to excellent with ICC&#x2009;=&#x2009;0.90-0.91 [0.85-0.95] (k&#x2009;=&#x2009;228 and 608, respectively), with sensor technology moderating the results. However, substantial heterogeneity and wide ranges of study-level estimates indicated considerable variability across moderators, linear position transducer (LPT) generally showing more consistent performance than inertial measurement units (IMU). Part II: Velocity-based 1RM prediction showed ICCs&#x2009;=&#x2009;0.90 [0.83-0.94] (k&#x2009;=&#x2009;124) and ICC&#x2009;=&#x2009;0.91 [0.72-0.98] (k&#x2009;=&#x2009;9); for reliability and validity, respectively. DISCUSSION: Commercial velocity sensors generally provide high relative validity and reliability. Results varied depending on exercise complexity, intensity, sensor technology, and modeling approach. While velocity-based 1RM prediction demonstrated high average validity, large heterogeneity in lower body exercises significantly biased the results. Furthermore, the dearth of measurement error and agreement analyses prohibits final conclusions. CONCLUSION: Therefore, velocity-based monitoring and 1RM prediction require cautious interpretation, as sensor- and exercise-specific evidence remains limited.

Load&#x2013;velocity relationship

Effectiveness of Wearable Digital Therapeutics in Improving Sleep Outcomes Among Individuals With Insomnia: Systematic Review and Meta-Analysis of Randomized Controlled Trials.

BACKGROUND: Wearable devices are increasingly used for sleep monitoring and as adjunctive treatment. Existing meta-analyses mostly pool composite digital therapies and rarely isolate stand-alone wearables or distinguish between objective and subjective end points. Whether stand-alone wearable interventions improve sleep outcomes in adults with insomnia, and which factors moderate treatment heterogeneity, remains unclear. OBJECTIVE: This study aims to evaluate the effectiveness of wearable digital interventions on sleep outcomes in adults with insomnia versus control strategies and explore moderators of effectiveness, including device-wearing position, intervention duration, and control type, using meta-regression. METHODS: This systematic review and meta-analysis was conducted in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta&#x2011;Analyses) 2020 statement and the PRISMA-S (Preferred Reporting Items for Systematic Reviews and Meta&#x2011;Analyses Literature Search Extension) guideline. Five electronic databases and clinical trial registries were searched from inception to May 18, 2026. Eligible studies were randomized controlled trials (RCTs) evaluating wearable digital interventions in adults with insomnia compared with sham, waitlist, usual care, or active control conditions and had an intervention duration of at least 1 week. Study screening, data extraction, and risk-of-bias assessment were carried out independently by 2 reviewers. Pooled estimates were calculated using a restricted maximum likelihood random-effects model with the Hartung-Knapp-Sidik-Jonkman correction. Heterogeneity was assessed using the I&#xb2; statistic, and 95% prediction intervals (PIs) were calculated for the primary analyses. The certainty of evidence was rated using the GRADE (Grading of Recommendations, Assessment, Development, and Evaluation) approach. RESULTS: Sixteen RCTs (N=910) were included. Wearable digital interventions were associated with a significant reduction in objective sleep-onset latency (SOL; mean difference [MD] -4.52, 95% CI -8.38 to -0.67, PI -9.52 to 0.47 min) and a significant improvement in subjective sleep efficiency (SE; MD 2.00%, 95% CI 1.90%-2.11%, PI 1.85%-2.15%). Subjective total sleep time (TST) also showed a significant increase (MD 19.11, 95% CI 2.98-35.24, PI -16.20 to 54.43 minutes). Meta-regression showed that control type, intervention duration, and device location did not explain the heterogeneity of the insomnia severity index (ISI) (R&#xb2;=0). Sensitivity analysis confirmed the robustness of pooled ISI estimates, and an Egger test indicated no small-study effects (P=.07). Certainty of evidence ranged from moderate to high. CONCLUSIONS: Wearable digital interventions provide selective benefits for objective SOL, subjective SE, and subjective TST in adults with insomnia, with no improvement in overall ISI. Despite statistically significant effects on several sleep parameters, wide PIs, substantial heterogeneity, and limited study numbers indicate preliminary, nonconclusive findings. Wearables should be viewed as affordable adjunctive tools requiring further validation, not substitutes for first-line cognitive behavioral therapy for insomnia. Large-scale, long-term RCTs with standardized protocols and patient-level external validation are required to consolidate the evidence base.

Humans

Hand Pain and Sensory Deficits: Carpal Tunnel Syndrome: 2026 Revision. Using the Evidence to Guide Musculoskeletal Rehabilitation Practice.

SYNOPSIS: Carpal tunnel syndrome is common in women, manual laborers, and during pregnancy; it is often associated with medical conditions such as obesity and diabetes. The musculoskeletal rehabilitation clinician's approach to managing hand pain and sensory deficits associated with carpal tunnel syndrome should include prescribing a neutral-positioned wrist orthosis plus instructing the patient on how to modify activities, adjust ergonomics, and reduce exposure to risk factors. Here, we present for clinicians the most up-to-date information to guide their work in managing hand pain and sensory deficits associated with carpal tunnel syndrome. J Orthop Sports Phys Ther 2026;56(9):622-623. doi:10.2519/jospt.2026.0502.

Humans

Wearable Sleep Monitoring in Pediatric Acute Lymphoblastic Leukemia: Associations With Subjective Sleep Ratings and Neurocognitive Functioning.

BACKGROUND: Sleep disturbances are associated with increased fatigue, reduced quality of life, and neurocognitive dysfunction and have emerged as a common complication among pediatric cancer survivors. Sleep disturbances are particularly concerning given their potential to exacerbate existing neurocognitive impacts of cancer treatments. This pilot study examined the feasibility and acceptability of a home-wearable EEG-based sleep device (Sleep ProfilerTM) for acute lymphoblastic leukemia (ALL) survivors as well as associations between specific sleep parameters and neurocognitive functioning. PROCEDURE: Children (ages 8-12; M = 10 years, SD = 1.6; N = 23) >6 months post-treatment for ALL were enrolled at clinical visits and wore the Sleep ProfilerTM for two consecutive nights at home, followed by neurocognitive testing of attention, inhibitory control, working memory, and processing speed. Parents completed subjective measures of child sleep, anxiety, depression, and acceptability. Feasibility reflected the percentage of children wearing the device at least one night and the percentage of nights with good EEG quality data. RESULTS: All participants wore the device both nights, with 84% meeting the threshold for good quality measurement. Few children met recommended quantity and quality sleep thresholds based on objective measurement, including 5 patients with elevated snoring levels; 43.5% of subjective ratings fell above the threshold for sleep disturbance. Greater sleep latency was associated with worse inhibitory control (r = -0.42, p = 0.046), and total sleep time was positively associated with inhibitory control and attention. CONCLUSIONS: Findings confirm the feasibility and acceptability of home EEG sleep monitoring in school-age survivors, and associations of sleep latency and snoring with reduced neurocognitive functioning may offer modifiable risk factors for aspects of neuropsychological dysfunction common in pediatric survivorship. CLINICAL TRIAL REGISTRATION: At the time this study was conducted, we were not required to register the study on ClinicalTrials.gov. It was a single-institution feasibility study without intervention, which was not considered a clinical trial.

Humans

One in three patients with positional obstructive sleep apnea does not benefit from positional therapy: Insights from a home-based trial.

PURPOSE: Positional obstructive sleep apnea (POSA) is the most common phenotype of obstructive sleep apnea, yet patient selection for positional therapy (PT) remains suboptimal. With this analysis we aimed to clarify how many patients with POSA may not require PT because they do not habitually sleep supine at home, and how many fail vibrotactile PT despite appropriate indication. METHODS: We conducted a retrospective observational study of consecutive adults with POSA evaluated at a tertiary sleep center between 2021 and 2024. All patients underwent a home-based trial with a neck-based vibrotactile positional therapy device (Night Shift&#x2122;), consisting of monitoring mode followed by therapy mode. Outcomes included the proportion of non-supine sleepers at home, failure rate of vibrotactile PT, device compliance and differences in supine sleep time between diagnostic testing and home monitoring. RESULTS: Of 92 screened patients, 74 met inclusion criteria (mean age 60.3&#x202f;&#xb1;&#x202f;13.2 years; mean AHI 22.9&#x202f;&#xb1;&#x202f;13.3 events/h). Fifteen percent (11/74) did not habitually sleep supine at home, indicating no clinical need for PT, and an additional 14.8% (11/74) failed vibrotactile PT. Overall, 30% of patients were either unlikely to benefit from PT or failed therapy. Non-response was frequently associated with psychotropic or sedative medication use and neurological or sleep-related comorbidities. CONCLUSION: A substantial proportion of patients diagnosed with POSA either do not require or fail vibrotactile treatment in real-world conditions. Incorporating a brief home monitoring and therapy trial into routine clinical practice may optimize patient selection, reduce unnecessary costs, and improve personalized management of POSA.

Humans

Efficacy of targeted neuromodulation treatments: a clinical report.

BACKGROUND: Peripheral neuropathy is a debilitating condition characterized by chronic pain, numbness, tingling, burning, and tightness/swelling. Conventional therapies often focus on symptom management, and some patients experience chronic and refractory symptoms. RESEARCH DESIGN AND METHODS: This retrospective clinical analysis evaluated the clinical outcomes of neuromodulation neuropathy treatment using the NeuroGen-Series device in patients with diabetic peripheral neuropathy (DPN) or idiopathic peripheral neuropathy (IPN). 9,805 unique patients who underwent 133,741 treatments between 18 August 2017, and 23 July 2024, were analyzed. Patients were divided into treatment completers (&#x2265;24 sessions) and noncompleters (<24 sessions). Paired t-tests confirmed statistically significant reductions in pre- and post-treatment symptom scores (p&#x2009;<&#x2009;0.001). RESULTS: Among completers, symptom severity decreased by an average of 46.2%. Tingling and pain showed the greatest improvement, while tightness/swelling and numbness showed the least reduction. 64% of patients reported improvement after one session, and 84% reported improvement after 24 sessions. Nonresponders accounted for 5.8% of patients overall. Younger patients and those with higher initial symptom severity were more likely to discontinue treatment. CONCLUSIONS: Overall, neuromodulation treatment resulted in statistically significant reductions in symptom severity, though nonresponders and high attrition rate highlight the need for individualized treatment strategies and further investigation.

Humans

Initial 4-Year Experience With Microaxial Flow Pumps Within a Tertiary Centre in Regional Australia.

BACKGROUND & AIM: The Microaxial Flow Pump (MFP) is a miniaturised rotary pump that aspirates blood from the left ventricle and expels it into the ascending aorta. It unloads the left ventricle and increases mean arterial pressure and cardiac output. MFP is most commonly utilised in cardiogenic shock, for protected percutaneous coronary intervention (PCI), and for ventricular offloading in veno-arterial extracorporeal membrane oxygenation (VA-ECMO). METHOD: We conducted a retrospective review of all patients who underwent MFP insertion at John Hunter Hospital, Australia. Categorical data are represented as counts and percentages, with continuous variables described as means with standard deviations. RESULTS: Twenty-three MFP devices were inserted between September 2020 and May 2024. Five (22%) were for protected PCI, three (13%) for venting with VA-ECMO (ECPELLA), and 15 (65%) for acute coronary syndrome (ACS) and cardiogenic shock. The median age for the overall cohort was 62 years, with a 74% male predominance. Eighty percent of the protected PCI cohort were elective outpatient procedures, and there were no deaths in this cohort. The mortality in the ECPELLA group was 67%. Thirteen (87%) of the patients with cardiogenic shock presented with an anterior infarct, and 53% had cardiac arrest on admission. The overall morality in the cardiogenic shock cohort was 40%. Complications in this cohort included limb ischaemia in four patients (17%) and site bleeding in seven patients (30%). Four patients (17%) required vascular surgery intervention. CONCLUSION: Our initial experience showed the use of MFP in a tertiary centre was safe and feasible, allowing progression from protected percutaneous intervention to acute cardiogenic shock.

Humans

Multicenter randomized effectiveness/implementation trial of a digital self-management support tool to improve the quality of life during adjuvant hormonal therapy for patients with early breast cancer: The HOPE trial.

BACKGROUND: For patients with hormone receptor (HR) positive early breast cancer (BC), adjuvant endocrine therapy (ET) represents the cornerstone of treatment. However, 75% of patients experience ET-related symptoms that negatively affect their quality of life (QOL). Despite their high prevalence, these symptoms are often underestimated and under-addressed during consultations. As a result, non-adherence to ET is common and remains a major barrier for optimal disease and survival outcomes. METHODS: National, prospective, randomized, open-label hybrid type 1 effectiveness/implementation trial conducted in France comparing a personalized digital health pathway plus standard of care (SoC) vs. SoC alone in patients with HR+ early BC reporting ET-related symptoms. 180 patients will be randomized 1:1 to receive either 12&#xa0;weeks of the digital health pathway or 12&#xa0;weeks of SoC. The intervention is anchored by the Resilience&#xa9; digital companion including remote symptom and needs assessment, an introductory nurse-navigator phone call, and access to personalized, symptom-specific online educational and self-management programs (physical activity, yoga, meditation or cognitive behavioral therapy). In both arms, patients will be invited to wear a wearable device to objectively monitor behavioral parameters. The primary endpoint is the ET symptoms scale of the European Organization for Research and Treatment of Cancer (EORTC) QLQ-BR45 over 12-weeks. Secondary endpoints include other QOL domains, self-reported ET adherence, eHealth literacy, self-efficacy, and evaluation of the implementation process. DISCUSSION: This study should provide evidence on the effectiveness and real-world implementation of a personalized digital health pathway to improve QOL in patients experiencing ET-related symptoms. TRIAL REGISTRATION: ClinicalTrials.gov NCT06781996; Protocol version 3.0.

Humans

Smart crutch tipsTM real-time feedback improves adherence to partial weight-bearing protocols following lower extremity fracture surgery: a pilot study.

PURPOSE: To evaluate the effectiveness of Smart Crutch Tips&#x2122; in promoting adherence to prescribed early partial weight-bearing (PWB) protocols and to assess patient experience with real-time weight-bearing feedback during home rehabilitation. METHODS: Twenty patients with lower extremity fractures prescribed partial weight-bearing (PWB) were randomized into two groups utilizing real-time feedback crutch tips (RFC). The Intervention group (n&#x2009;=&#x2009;10) used Smart Crutch Tips&#x2122; (ComeBack Mobility Inc., Kiev, Ukraine), which provided real-time feedback on weight-bearing compliance. The Control group (n&#x2009;=&#x2009;10) also used crutches equipped with Smart Crutch Tips&#x2122;, but notifications were disabled, allowing passive data collection without patient feedback. Weight-bearing compliance was defined as the percentage of steps within &#xb1;&#x2009;10% of the prescribed target. Secondary outcomes included patient satisfaction and device usability assessed using the System Usability Scale (SUS) throughout the home rehabilitation period. RESULTS: The Intervention group demonstrated significantly greater PWB compliance compared with the Control group (73.6% vs. 21.1%, p&#x2009;<&#x2009;0.01). The Intervention group reported a mean SUS score of 84.25, indicating excellent usability. No device-related complications or adverse events were observed. Patient satisfaction, assessed through video interviews, was high, with participants in the Intervention group expressing a strong willingness to recommend the device to others with similar injuries and rating it 10 out of 10. CONCLUSION: Smart Crutch Tips&#x2122; significantly improved adherence to prescribed partial weight-bearing protocols following lower extremity fracture surgery. The RFC device demonstrated high usability, excellent patient satisfaction, and no device-related complications during home rehabilitation throughout the study period.

Humans

The Effect of Slow Deep Breathing Relaxation Exercise on Pain and Anxiety Levels During and Post-Chest Tube Removal After CABG.

Chest tube removal after coronary artery bypass graft is frequently reported by patients as stressful and painful, highlighting the need for effective nonpharmacological interventions. Slow deep breathing relaxation exercises (SDBREs) may serve as a simple nursing strategy to reduce discomfort. In this study, we aimed to evaluate the effect of SDBRE on pain and anxiety during and after chest tube removal following coronary artery bypass grafting in Nablus hospitals. An experimental design was used with 80 patients recruited from 2 hospitals. Participants were randomly assigned to either an intervention group (n = 40) that practiced SDBRE or a control group (n = 40) that received standard care. Data were collected through a self-administered questionnaire, the Numeric Pain Scale, and the Visual Anxiety Scale. Data collection occurred from March to October 2024. The intervention group reported significantly lower pain scores during removal (M: 5.325 vs 7.125, P < .001) and after removal (P < .001). Anxiety scores were significantly lower both during and after removal (P < .001). Pain correlated with duration, with more complex operations and prolonged chest tube insertion linked to higher scores. SDBRE significantly reduced pain and anxiety during and after chest tube removal, supporting its integration into routine postoperative nursing care.

Humans

Ten years on, still out of reach: barriers to PrEP access and retention in France according to frontline actors (QualiPrEP Study).

Pre-exposure prophylaxis (PrEP) for HIV has been available in France since 2014, and reimbursed since 2016, with general practitioners allowed to prescribe it since 2021. Despite these policy advances, uptake remains low among some of the most affected populations. This community-based qualitative study explored barriers to PrEP access and retention ten years into its implementation.Interviews were conducted with 28 PrEP frontline actors (healthcare professionals and community-based workers involved in promoting, prescribing, or supporting PrEP). The sample included one group discussion (n = 5), two triads (n = 6), two dyads (n = 4), and nine individual interviews (n = 13). Thematic analysis was inductive, with barriers classified across four main domains.Participants were mostly cisgender men, median age 48, born in France and abroad, and employed by NGOs in Paris. Thirteen barriers and four major themes emerged: (1) Internal psychosocial barriers: lack of knowledge, negative health-related reactions; HIV stigma; STI risk perception, taboos; (2) Internal pragmatic barriers: perceived limits of protection, usage and follow-up constraints; (3) External psychosocial barriers: limited physician knowledge and reluctance; (4) External pragmatic barriers: communication failures; structural constraints, lack of human and financial resources.Findings call for more targeted messaging, simplified care models and provider training. They highlight the need to address social and symbolic dimensions of PrEP, with insights from those supporting users to ensure more equitable implementation.

Humans

Effects of Vacuum Compression Therapy on Healing of Chronic Lower Limb Ulcers: A Randomised Controlled Study.

Chronic lower limb ulcers remain difficult to manage when unresponsive to conventional treatment. This study evaluated the clinical and physiological effects of vacuum compression therapy on wound healing and quality of life. Fifty patients with chronic lower limb ulcers were randomised to receive 12 sessions of vacuum compression therapy plus standard care or standard care alone over 4&#x2009;weeks. Wound dimensions, exudate, pain intensity and quality of life were assessed at baseline and post-treatment. Estimated wound volume was calculated as length&#x2009;&#xd7;&#x2009;width&#x2009;&#xd7;&#x2009;depth. Tissue oxygenation was measured at the dorsum of the foot in the experimental group. The vacuum compression therapy group showed greater improvements in wound width, depth, volume and quality of life. Estimated wound volume decreased by 61% in the intervention group, whereas no statistically significant volume reduction was observed in controls. Local tissue oxygenation in the experimental group increased by 43%. Baseline wound size was associated with poorer quality of life. Vacuum compression therapy may enhance wound healing and quality of life in patients with chronic lower limb ulcers. Observed increases in local tissue oxygenation represent exploratory physiological findings within the treated cohort that warrant controlled comparative evaluation. Trial Registration: ClinicalTrials.gov identifier: NCT07737184.

Humans