Search PubMedSearch

SEARCH · Search PubMed

Results for “anal barrier device”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

200 recordsLinked to original sources

Clinical Trial: Effectiveness and Safety of a Novel Anal Insert Device for Treatment of Faecal Incontinence.

BACKGROUND: Treatment options for medically-refractory faecal incontinence (FI)-including anorectal biofeedback, dextranomer injection, and sacral nerve stimulation-are limited and outcomes are often suboptimal. Anal or vaginal insert devices are infrequently used. AIMS: We evaluated the safety and effectiveness of a new anal insert device (StaySure) in patients with FI. METHODS: Patients with FI for&#x2009;&#x2265;&#x2009;6&#x2009;months and&#x2009;&#x2265;&#x2009;4 moderate or large FI episodes during a 4-week baseline entered a 2-4&#x2009;week fitting/run-in period to individualise device size (10 or 13&#x2009;mm) followed by a 4-week treatment period. Outcomes included effectiveness, safety, and quality of life (QoL). The primary outcome was the proportion achieving a&#x2009;&#x2265;&#x2009;50% reduction in FI frequency. RESULTS: Of 124 enrolled patients, 98, 71, and 61 progressed through the baseline, fitting/run-in, and treatment phases respectively, with few exclusions due to device intolerance. In the intent-to-treat cohort of 59 participants (93% women), mean (SD) number of days with FI declined from 13.2 (7.0) to 6.3 (6.9), and FI weekly episodes declined from 5.4 (6.9) to 2.1 (5.1) (69% reduction; p&#x2009;<&#x2009;0.001) with similar results for both device sizes. The primary endpoint was achieved in 76.3% of participants; 54.2% achieved&#x2009;&#x2265;&#x2009;75% reduction. The FIQoL overall score increased from a mean (SD) of 1.9 (0.6) to 2.3 (0.6) (p&#x2009;<&#x2009;0.001), indicating improved QoL. Improvements in FI frequency, FIQoL exceeded minimal clinically important difference thresholds, confirming clear clinical benefit. No treatment-related serious adverse events were reported. CONCLUSIONS: The StaySure anal insert device is safe, well tolerated, and effective in reducing FI in patients with moderate to severe symptoms refractory to conservative therapies. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT03898778.

Adult

Predictive value of anal sphincter electromyography for sacral neuromodulation test-phase outcomes.

BACKGROUND: Sacral neuromodulation (SNM) is an established therapy for refractory pelvic organ dysfunction. Anal sphincter electromyography (EMG) is commonly used preoperatively to assess sacral and peripheral nerve integrity. However, the prognostic significance of chronic neurogenic EMG changes for SNM outcomes remains unclear. OBJECTIVE: To evaluate whether chronic neurogenic changes on preoperative anal sphincter EMG predict the outcome of the SNM test phase. METHODS: We retrospectively analysed 62 consecutive patients with bladder and/or bowel dysfunction or pelvic pain who were candidates for SNM treatment and who underwent preoperative anal sphincter EMG. EMG findings were classified as normal or showing chronic neurogenic changes. SNM test-phase success was defined as a &#x2265;50% improvement of symptoms at 24&#xa0;days. Outcomes were compared between EMG groups. RESULTS: Of the 62 patients (49 women, 13 men), 30 (48%) had normal EMG findings and 32 (52%) showed chronic neurogenic changes. Overall, the SNM test phase was successful in 47 patients (76%). Success rates were similar in patients with normal EMG (72%) and neurogenic EMG changes (79%), with no statistically significant difference (p&#xa0;=&#xa0;0.878). Sex-stratified analyses revealed no significant association between EMG findings and test-phase success in women or men. CONCLUSIONS: Chronic neurogenic changes on anal sphincter EMG do not predict SNM test-phase outcomes. These findings suggest that abnormal sphincter EMG results should not be used as a standalone criterion to exclude patients from SNM therapy. SIGNIFICANCE: Signs of neurogenic damage on anal sphincter EMG are not an indicator of reduced neuromodulatory capacity or diminished clinical response to SNM.

Humans

From human papillomavirus (HPV) infection to HPV-associated cancers in systemic lupus erythematosus: A systematic review and Meta-analysis.

OBJECTIVE: The current cervix-focused screening paradigm in systemic lupus erythematosus (SLE) may underestimate extra-cervical anogenital cancer risk. This meta-analysis aimed to quantify the risk of human papillomavirus (HPV) infection and HPV-associated cancers in SLE patients. METHODS: A comprehensive search was conducted in PubMed (2010), Embase (2010), and Cochrane Library (2010) to August 8, 2025. Odds Ratios (ORs) and Standardized Incidence Ratios (SIRs) with 95% Confidence Intervals (CIs) were calculated. The study protocol was registered with PROSPERO (CRD420251122192). RESULTS: SLE was associated with significantly increased odds of HPV infection (OR&#xa0;=&#xa0;4.12, 95% CI 2.03, 8.32). We further assessed the risk of HPV-associated malignancies in SLE patients. SLE patients exhibited substantially elevated risks across multiple HPV-associated cancers (SIR&#xa0;=&#xa0;1.90, 95% CI 1.51, 2.38). The risk of cervical cancer was more than doubled (SIR&#xa0;=&#xa0;2.25, 95% CI 1.75, 2.89). Notably, even higher risks were observed for extra-cervical anogenital cancers, namely vulvar/vaginal cancers (SIR&#xa0;=&#xa0;5.60, 95% CI 3.71, 8.43). CONCLUSIONS: SLE is associated with elevated risks of HPV infection and a broad spectrum of HPV-associated cancers. Subgroup analyses suggested that cyclophosphamide use, multiple sexual partners, and Asian populations may constitute higher-risk subgroups. These findings highlight the need for additional prospective evidence to better characterize HPV-associated cancer risks in SLE patients.

Humans

Intersphincteric resection versus abdominoperineal resection for lower rectal cancer: A systematic review and meta-analysis.

BACKGROUND: The optimal surgical approach for lower rectal cancer (LRC) remains debated, particularly between intersphincteric resection (ISR) and abdominoperineal resection (APR). While ISR offers potential sphincter preservation, its oncological efficacy compared to APR is unclear. METHODS: A systematic review was conducted to compare clinical and oncological outcomes of ISR versus APR in LRC patients. On December 8, 2024, a comprehensive search of Medline, Embase, Cochrane Library, Scopus, and Web of Science identified 24 retrospective studies involving 4502 patients. Key outcomes analyzed included positive circumferential resection margin (CRM), number of harvested lymph nodes (LNs), local recurrence (LR), length of hospital stay (LOS), early postoperative complications, and survival. RESULTS: Twenty-four retrospective studies involving 4502 patients (ISR: 2266 (50.3%) and APR: 1558 (34.6%)) met the eligibility criteria. ISR was associated with significantly lower rates of positive CRM (risk ratio (RR): 0.41, p&#x202f;<&#x202f;0.001), decreased early postoperative complications (RR: 0.76, p&#x202f;<&#x202f;0.001), lower LR (RR: 0.63, p&#x202f;=&#x202f;0.0038), and improvement in five-year overall survival (5YOS) (hazard ratio (HR)&#x202f;=&#x202f;0.42, p&#x202f;<&#x202f;0.001) and five-year disease-free survival (5YDFS) (HR&#x202f;=&#x202f;0.59, p&#x202f;<&#x202f;0.001). CONCLUSIONS: ISR demonstrates several advantages over APR in selected LRC patients, including lower rates of positive CRM, fewer early postoperative complications, reduced LR, greater LN harvest, shorter LOS, and improved long-term survival outcomes (5YOS and 5YDFS). Therefore, ISR can be considered a safe and effective alternative to APR in appropriately chosen patients, with careful patient selection and surgical expertise remaining essential.

Humans

Effectiveness and usability of artificial intelligence-powered assistive technologies in Supporting daily activities of children with cerebral palsy: a systematic review.

BACKGROUND: Cerebral Palsy (CP) is the main cause of motor disabilities in childhood, necessitating innovative approaches to rehabilitation and assistive technology (AT). Simultaneously, artificial intelligence (AI) is increasingly being integrated into devices to create more adaptive, personalized, and effective AT. This systematic review aimed to evaluate the effectiveness and usability of AI-powered assistive technologies designed to support daily activities and rehabilitation in children with CP. MATERIALS AND METHODS: Five databases, including Scopus, Web of Science, PubMed, Embase, and IEEE Xplore, were systematically searched, and 23 articles were included in the final analysis. Articles were identified, selected, and categorized into emerging thematic areas based on the primary function and application of the technology. RESULTS: Five key thematic topics were identified: 1) AI-driven motor rehabilitation and gait training for functional mobility; 2) intelligent assessment and monitoring systems for clinical decision support; 3) AI-supported communication, social interaction, and intention recognition tools; 4) gamified and virtual reality-based interventions to enhance engagement and usability; and 5) smart assistive systems supporting daily living and independent mobility. The findings demonstrate a strong trend toward the application of AI technologies in personalized, engaging, and data-driven interventions for children with CP. However, the field is predominantly in the proof-of-concept stage, with limitations including small sample sizes, lack of long-term clinical validation, challenges in user-centered design, and usability for children with CP. CONCLUSION: AI-powered assistive technologies hold significant potential for transforming the care of children with CP by enabling highly personalized and engaging interventions. To actualize this potential, future work must realize that practical application remains challenging owing to limited clinical validation, technological integration, and usability barriers for children with CP. Future research must prioritize user-centered design and multidisciplinary collaboration to ensure that AI and robotic advancements improve the usability and quality of life for children with CP.

Humans

[Analysis of a Chinese pedigree affected with Townes-Brocks syndrome due to a novel variant of SALL1 gene and a literature review].

OBJECTIVE: To analyze a novel exonic variant of the SALL1 gene and its impact on the binding site of SALL protein. METHODS: Clinical data of three children diagnosed with Townes-Brocks syndrome and their family members who had presented at the First Affiliated Hospital of Shandong First Medical University in April 2022 were retrospectively collected. The pathogenic variant was identified through whole-genome sequencing (WGS) and validated by Sanger sequencing. Protein structural prediction was performed using AlphaFold and PyMOL software to construct three-dimensional models of the wild-type and mutant proteins. Additionally, previously reported cases were systematically reviewed. This study was approved by the Medical Ethics Committee of the hospital (Ethics No.: 2023-386). RESULTS: The proband was one of triplet sisters born at 34+4 gestational weeks. All three cases had presented with anal atresia and rectovaginal fistula, and case 3 also had toe malformation of left foot. WGS revealed a novel heterozygous c.757C>T (p.Gln253*) variant in the SALL1 gene, which was predicted to be pathogenic. Sanger sequencing confirmed co-segregation of the variant with the disease within the family. Protein structural modeling demonstrated that the variant has introduced a premature stop codon at position 253, resulting in a truncated protein. CONCLUSION: Above finding has enriched the mutation spectrum of the SALL1 gene in association with Townes-Brocks syndrome, which also represented a rare case of anal atresia in triplets, and provided a basis for molecular diagnosis, genetic counseling, and further research.

Humans

Home-Based Cardiac Rehabilitation Using a Smart Ring and Telephone Counselling: A Randomized Controlled Trial.

BACKGROUND: Home-based cardiac rehabilitation (HB-CR) is a promising alternative to center-based cardiac rehabilitation as it can address several barriers impeding CR implementation because of its enhanced accessibility. However, to date, HB-CR has not garnered adequate attention due to a lack of communication between patients and medical staff. In this study, we aimed to investigate the effectiveness of HB-CR by monitoring the pulse rate (PR) using a smart ring equipped with photoplethysmography. METHODS: Patients with cardiovascular disease were educated on structured HB-CR methods following a symptom-limited cardiopulmonary exercise test (CPET), and were instructed to wear the device during the exercise session. The recorded PR was uploaded to a website via a smartphone and monitored by medical staff. Patients were randomly assigned to one of two groups: intervention or control group. The intervention group received weekly telephone counselling and was encouraged to maintain optimal levels of physical activity. In contrast, the control group only recorded their exercise data without additional interventions. After 3 months of training, the CPET was performed. RESULTS: Among the 64 randomized patients (32 in each group), an intention-to-treat analysis showed that peak oxygen consumption increased over time in both the groups, with a significantly greater improvement in the intervention group. The group-by-time interaction for peak oxygen consumption was statistically significant (estimated mean difference, 2.0 mL/kg/min; 95% confidence interval, 0.7-3.3; P = 0.004). CONCLUSION: HB-CR using a smart device was effective in improving oxygen consumption. However, appropriate monitoring and timely counselling by medical professionals are important for improved outcomes. TRIAL REGISTRATION: Clinical Research Information Service Identifier: KCT0005893.

Humans

An impact assessment of the European medical device regulations implementation - the current status quo.

BACKGROUND: This research aims to assess the current impact of the medical and in-vitro diagnostic devices regulations (MDR/IVDR) on the device industry in the EU, under the lens of postimplementation and the amending regulation, and in advance of the final transition to the IVDR/MDR in the future. RESEARCH DESIGN AND METHODS: A quantitative survey was administered to a diverse cohort of medical device enterprises, ranging from micro to large organizations. RESULTS: The survey indicates that the MDR/IVDR has harmed innovation, leading many manufacturers to seek initial device approval and launch elsewhere before in Europe. There is evidence that some manufacturers have rationalized their existing product portfolios and removed devices from the market as they stated they would in previous industry surveys. The MDR/IVDR has been shown to negatively impact manufacturers, with increased costs related to notified body (NB) fees, maintaining and updating documentation, recertification fees, and hiring additional staff. CONCLUSION: This study provides a current status of the effects of MDR/IVDR on manufacturers and finds that despite amending regulations and other interventions taken by the EU to mitigate regulatory burden, ensure product availability, and address stakeholder concerns, the EU is no longer the market of choice for new products.

Equipment and Supplies

Comparison of three tracking methods to assess usage of two pediatric powered mobility devices for young children with cerebral palsy.

Powered mobility devices are underutilized for promoting self-initiated mobility in young children with cerebral palsy due to prioritization of walking, caregiver effort, device characteristics, and environmental factors. Understanding device usage patterns is important to assess the impact of powered mobility interventions on child outcomes. As part of clinical trial (NCT04684576), three objective tracking methods including integrated loggers, Global Positioning System trackers (GPST), and caregiver reported activity logs (CRAL) were compared to provide insights into device usage patterns. Metrics included play session frequency, session duration, total usage minutes, and unique usage days for two powered mobility devices: Modified Ride-on Cars (MROC) and the Permobil Explorer Mini (EM). Twelve children with cerebral palsy used each device for eight consecutive weeks in home and community settings (16&#x2009;weeks total), with device ordered randomized. Results showed no significant differences among tracking methods for the MROC. For the EM, only session duration differed between GPST and CRAL. Correlation analysis revealed variable relationships amongst tracking methods for both devices. The EM was used more frequently than the MROC, with significantly greater total usage minutes and session duration via CRAL, not GPST. The findings highlight the need for reliable tracking technologies that can be used across powered mobility devices.

Child, Preschool

Review of regulatory requirements for benefit-risk assessment for medical devices: uncovering existing methodologies.

INTRODUCTION: A positive benefit-risk profile is a prerequisite for the market approval of medical devices. However, regulations are often criticized for providing limited information on benefit-risk assessment (BRA) despite growing expectations for quantitative methods. A clearer understanding of regulatory requirements, existing methodologies, and unresolved issues is needed. AREAS COVERED: Relevant regulatory documents referencing BRA for medical devices were systematically identified, with a primary focus on the European regulation followed by screening to extract BRA&#x2011;related requirements and any explicitly or implicitly described methods. The findings were analyzed and consolidated by BRA context, type, objective, methodological description, and implementation, thereby establishing a basis for the BRA methodological landscape. EXPERT OPINION: BRA is not a single concept, but a set of context&#x2011;dependent assessments across lifecycle of a medical device. BRA within clinical evaluation framed into BRAs of risk management holds a pivotal role and is supported by the most detailed methodological guidance, although BRAs in other contexts are important. A structured overview of existing BRA requirements clarifies their treatment across regulatory documents. By differentiating BRA contexts, types, objectives, and required methodological detail, the analysis supports a more transparent understanding of BRA and helps identify priorities for methodological refinement and interface clarification.

Risk Assessment

Insights from expert panels on the EU clinical evaluation consultation procedure.

BACKGROUND: The Clinical Evaluation Consultation Procedure (CECP) under the EU Medical Device Regulation aims to strengthen and harmonize the assessment of high-risk medical devices. This review summarizes early insights from expert panels to support improved clinical evaluation practices. RESEARCH DESIGN AND METHODS: This review analyses 34 expert panel opinions derived from 281 CECP submissions between April 2021 and December 2025. Statements from opinions were systematically extracted, de-duplicated, and grouped into thematic categories, with independent review and validation. The analysis focuses on common challenges found during the consultation procedure of the expert panels on the content of the clinical assessment in relation to clinical evidence, benefit-risk assessment, intended purpose alignment, and post-market clinical follow-up planning. RESULTS: Expert panel findings highlight recurrent issues in the sufficiency, consistency, and transparency of clinical evidence, underscoring the need for improved standardization and clearer guidance. CONCLUSIONS: Strengthening documentation quality and alignment across stakeholders will enhance the robustness, efficiency, and predictability of conformity assessments for high-risk medical devices.

Humans

Percutaneous left ventricular assist device in cardiogenic shock associated with and without acute myocardial infarction: a real-world retrospective cohort study.

BACKGROUND: Percutaneous left ventricular assist devices (pLVAD, such as Impella), are increasingly used for cardiogenic shock (CS). Outcomes may differ between acute myocardial infarction-related CS (AMI-CS) and non-AMI CS due to differing pathophysiology and trajectories. METHODS: Using the USA TriNetX Network (2016-2024), we identified adults with CS treated withpLVAD. AMI-CS was defined by MI within seven days of implantation; non-AMI CS included all patients with CS not attributable to acute MI, representing heterogeneous etiologies such as decompensated cardiomyopathy, myocarditis, valvular failure, pulmonary vascular causes, and arrhythmic shock. Patients with recent coronary artery bypass graft (CABG) were excluded. Propensity matching produced two balanced cohorts (n&#x2009;=&#x2009;2,026 each). RESULTS: Among 6,873 AMI-CS and 4,521 non-AMI CS patients, matched groups were similar (mean age 63&#x2009;years, 26% female). AMI-CS had higher mortality at 30&#x2009;days (hazard ratio [HR] 1.19, p&#x2009;=&#x2009;0.002), 90&#x2009;days (HR 1.13, p&#x2009;=&#x2009;0.02), and 180&#x2009;days (HR 1.14, p&#x2009;=&#x2009;0.007). Heart failure (HF) exacerbations (HR 1.21, p&#x2009;<&#x2009;0.001) and pulmonary edema (HR 1.23, p&#x2009;=&#x2009;0.005) were also more common in AMI-CS. Stroke, ventricular arrhythmias, cardiac arrest, acute kidney injury, major bleeding, vascular complications, and hemodialysis were comparable. CONCLUSION: AMI-CS patients supported with pLVAD experienced higher mortality and greater HF-related morbidity than non-AMI CS.

Humans

Effect of Music on Pain, Anxiety, and Satisfaction During Intrauterine Device Application: A Randomized Clinical Trial.

This randomized controlled trial aimed to determine the effect of music played during intrauterine device (IUD) insertion on perceived pain, state anxiety, and satisfaction levels. The study was conducted with 70 women who applied to a maternal and child health and family planning center and were randomly assigned to the intervention and control groups using simple randomization. Data were collected using a Demographic Information Form, the State-Trait Anxiety Inventory (STAI-I), and the Visual Analog Scale (VAS), as well as Bluetooth speakers and the musical piece Evgeny Grinko-Valse. Participants in the intervention group listened to music before and during the IUD insertion procedure, whereas the control group received routine care only. Data were analyzed using SPSS version 26 with appropriate descriptive and inferential statistical methods. Women in the music group had significantly lower perceived pain (p&#x2009;<&#x2009;0.001) and state anxiety levels during the procedure (p&#x2009;=&#x2009;0.022), and significantly higher satisfaction levels compared with the control group (p&#x2009;<&#x2009;0.001). In addition, post-procedure state anxiety levels were positively correlated with pain intensity experienced during and after the procedure (r&#x2009;=&#x2009;0.542 and r&#x2009;=&#x2009;0.496, respectively; p&#x2009;<&#x2009;0.001), and negatively correlated with procedural satisfaction (r&#x2009;=&#x2009;-0.652; p&#x2009;<&#x2009;0.001). These findings suggest that listening to music during IUD insertion may help reduce pain and anxiety while potentially enhancing patient satisfaction. Trial Registration: NCT06215183.

Humans

Assessment of Surgical Salvage Outcomes for Exposed Cranial Neuromodulating Devices.

OBJECTIVES: Implanted neuromodulating devices (NMDs) such as cochlear implants (CIs) and deep brain stimulators (DBSs) are commonly used in modern medicine. Rarely, complications arise post-operatively, including hardware exposure. Traditional teaching suggests that these devices require removal if exposed; however, surgical salvage is a high risk, high reward alternative. We review our single institution experience managing NMD exposure with surgical salvage. METHODS: Retrospective chart review was performed on individuals who had a NMD implanted and underwent an attempt at surgical salvage for exposure during the study period (January 01, 2021 through December 31, 2023). Study outcome success was defined as maintaining a functional NMD 1&#x2009;year after salvage was attempted. Surgical techniques associated with successful salvage were compared. RESULTS: Nine of 729 patients (1.2%) implanted with NMDs experienced hardware exposure during this 2-year study period. Nine subjects were referred for NMD salvage; however, only 6 of 9 subjects (66.7%, CI&#x2009;=&#x2009;3; DBS&#x2009;=&#x2009;3) underwent NMD salvage attempts. Four of the subjects had successful salvage demonstrated successful salvage with a functioning NMD and without wound healing concerns 1&#x2009;year after their salvage procedure. CONCLUSIONS: Classic teaching states that exposed NMDs require explantation. However, this approach necessarily imposes time without benefit from the NMD between explantation and reimplantation. Our experience demonstrates that surgical salvage can be a successful alternative for the majority (66.7%) of individuals.

Humans

Phase 1 Study Evaluating Gefurulimab Pharmacokinetics and Safety Following Delivery Via Autoinjector or Prefilled Syringe With Needle Safety Device in Healthy Adults.

PURPOSE: Gefurulimab, a novel dual-binding nanobody targeting complement component 5 (C5), is in clinical development for anti-acetylcholine receptor antibody-positive generalized myasthenia gravis. Gefurulimab has a low molecular weight, enabling subcutaneous (SC) self-administration by autoinjector (AI) or prefilled syringe with needle safety device (PFS-SD). We compared gefurulimab pharmacokinetic (PK) exposure and safety in healthy adults following a single SC dose administered by AI versus PFS-SD. METHODS: In this phase 1, open-label, randomized, parallel-group study (NCT06208488), healthy participants aged 18 to 65 years were stratified by weight and randomized equally to 1 of 6 combination groups of device and injection site (abdomen/thigh/upper arm). Participants received a single SC dose of gefurulimab on day 1 and were assessed throughout the 92-day evaluation period. Primary endpoints were PK parameters for each device: maximum observed concentration (Cmax) and area under the serum concentration-time curve (AUCinf, AUClast). PK across injection sites, pharmacodynamics, safety, immunogenicity, and device performance were also assessed. FINDINGS: Overall, 175 participants were randomized: AI (n = 87), PFS-SD (n = 88). Geometric least squares mean ratios (90% CI) comparing AI/PFS-SD for Cmax, AUCinf, and AUClast were 97.6% (94.5-100.8), 99.6% (96.1-103.3), and 98.8% (95.2&#x2012;102.6), respectively. Secondary analyses found no meaningful differences in PK parameters across injection sites. Serum-free C5 concentrations over time, treatment-emergent adverse event (TEAE) profiles, and antidrug antibody responses were similar between cohorts. Most TEAEs were mild; none led to study discontinuation. IMPLICATIONS: SC administration of gefurulimab by AI and PFS-SD was well tolerated with comparable exposure, meeting bioequivalence criteria.

Humans

Prothrombin complex concentrate (PCC) vs. non-PCC strategies for warfarin reversal in left ventricular assist device recipients: A systematic review and meta-analysis.

BACKGROUND: Left ventricular assist devices (LVADs) prolong survival in end-stage heart failure, and warfarin thromboprophylaxis is recommended to prevent device thrombosis and thromboembolic complications. When bleeding occurs or emergency surgery is required, rapid anticoagulation reversal is critical. Prothrombin complex concentrate (PCC) provides rapid reversal; however, its risk-benefit profile in LVAD recipients remains unclear. We conducted a systematic review and meta-analysis comparing PCC with non-PCC strategies for warfarin reversal in LVAD recipients. METHODS: MEDLINE, Embase, and Scopus were searched through June 2025 for studies of PCC versus non-PCC strategies for warfarin reversal in LVAD recipients. Two reviewers independently extracted data. Random-effects models were used to pool arm-level estimates and to pool head-to-head comparisons using mean differences or risk ratios (RRs). RESULTS: Eighteen studies involving 779 patients were included. Arm-level pooled estimates for PCC versus non-PCC comparators were 24.0% versus 15.8% for mortality, 16.5% versus 12.1% for thrombotic events, and 3.1 versus 5.7 for FFP units. Arm-level time to INR correction was longer with PCC overall (16.5 versus 13.6&#xa0;h), driven by one elective cohort, but faster within the ICH subgroup (6.0 versus 13.7&#xa0;h). In head-to-head comparisons, PCC achieved faster INR correction than non-PCC comparators (mean difference&#xa0;-&#xa0;7.6&#xa0;h; p&#xa0;=&#xa0;0.001) and required fewer FFP units (-2.6&#xa0;units; p&#xa0;=&#xa0;0.019), with no significant difference in all-cause mortality (RR 1.14; p&#xa0;=&#xa0;0.490) or thrombotic events (RR 1.43; p&#xa0;=&#xa0;0.176). CONCLUSIONS: In head-to-head studies, PCC was associated with faster INR correction and lower FFP requirements than non-PCC strategies, whereas mortality and thrombotic events did not differ significantly. Given the observational evidence, wide confidence intervals, and heterogeneity, equivalent safety cannot be established, and prospective studies are needed to define the relative safety and effectiveness of the two approaches. IMPLICATIONS FOR CLINICAL PRACTICE: PCC-based strategies may be considered for urgent warfarin reversal in LVAD recipients, particularly when rapid INR reduction or avoidance of large-volume plasma transfusion is clinically important. Treatment decisions should account for the indication, bleeding severity, and underlying thrombotic risk. TRIAL REGISTRATION: CRD42024573925.

Humans

Sacral Neuromodulation in the Management of Refractory Pediatric Lower Urinary Tract Dysfunction.

INTRODUCTION: Sacral neuromodulation is currently used in the pediatric patient population for refractory lower urinary tract dysfunction (LUTD). Evidence, however, is currently limited for institutional experiences of long-term outcomes for sacral neuromodulation in the pediatric patient population. OBJECTIVE: The objective of this study is to perform a retrospective review of a large multi-institutional cohort of pediatric patients that underwent sacral neuromodulation (SNM) for refractory LUTD, focused on rates of symptom improvement, quality of life, and bowel-bladder dysfunction measures following device implantation. Secondary objectives included assessing device complication rates and device removals due to failure or successful resolution of symptoms. METHODS: We performed a retrospective cohort study of pediatric patients at three children's hospitals that underwent SNM device implantation for refractory LUTD. Patients 4-18 years of age who were diagnosed with refractory LUTD and managed at a participating institution with follow-up were included. Outcomes were evaluated at baseline and post-operatively after two-stage device implantation at initial follow-up and annually until device removal or final follow-up. RESULTS: From 2010 to 2022, a total of 205 children underwent SNM procedures at three pediatric hospital centers. 204 patients completed the two-stage procedure for permanent device implantation with a median follow-up of 3.4 years (1.3, 4.9). One hundred seventy-eight patients reported partial (25%) or complete (54%) device response/symptom improvement by final follow-up. Comparison of patient-reported validated questionnaires completed at baseline and by final follow-up visit revealed significant improvement in median Pediatric Quality of Life Inventory (PedsQL) (p&#x2009;=&#x2009;0.004) and Vancouver Nonneurogenic Lower Urinary Tract Dysfunction/Dysfunctional Elimination Syndrome bowel-bladder dysfunction (BBD) scores (p&#x2009;<&#x2009;0.001). Of those with any device complication (n&#x2009;=&#x2009;43;21%), 19 patients required device revision, and 20 required complete device removal. Separately, twenty-eight patients (13%) underwent device removal due to resolution of symptoms or treatment success at a median period of 5 years (4,7). CONCLUSION: SNM use demonstrated a majority of patients reporting at least partial subjective symptom improvement following device implantation across multiple institutions by final follow-up. SNM is a viable treatment option for refractory LUTD in the pediatric patient if willing to undergo an invasive procedure and in which thorough counseling of risks and benefits has occurred.

Humans

Copper-Containing Surface Engineering for Soft-Tissue Biomedical Devices: Structure-Function Relationships and Ion Release-Driven Biological Performance, A Systematic Review.

Copper and copper-based materials have gained increasing attention for the functional modification of implantable medical devices intended for prolonged soft-tissue contact, including vascular stents, catheters, and intrauterine devices. Owing to their broad-spectrum antimicrobial activity, redox reactivity, and involvement in angiogenesis and cellular signaling, copper-based systems offer significant potential for multifunctional surface engineering. However, achieving a balance between antibacterial efficacy, corrosion behavior, controlled ion release, and cytocompatibility remains a critical challenge. This PRISMA-compliant systematic review analyzes copper-containing materials and surface modification strategies for soft-tissue biomedical applications. A structured search of Scopus, Web of Science, and PubMed (2015-2025) identified 65 eligible studies. The review encompasses bulk copper-containing alloys, electrochemical and chemical surface modification techniques, physical vapor deposition approaches, and advanced hybrid systems integrating copper with polymers, hydrogels, or metal-phenolic networks. Across the reviewed literature, antibacterial performance was strongly dependent on copper concentration, microstructural distribution, and spatiotemporal ion release profiles. Moderate, well-controlled copper incorporation frequently improved antibacterial efficacy while maintaining acceptable hemocompatibility and cytocompatibility, particularly in vascular and blood-contacting devices. In contrast, excessive copper loading often accelerated corrosion and induced adverse cellular responses. Emerging multifunctional architectures demonstrated improved regulation of biological interactions, enabling simultaneous antibacterial, antithrombotic, and proendothelial effects. Overall, copper-based surface technologies represent a versatile platform for soft-tissue implant modification. Future translational progress will require precise control of copper release kinetics and comprehensive long-term in vivo validation to ensure safety and sustained therapeutic performance. From the authors' perspective, the most promising future direction involves multifunctional copper-based hybrid coatings capable of dynamically regulating ion release, host tissue integration, and antibacterial performance simultaneously. Strategies integrating hierarchical architectures, stimulus-responsive release systems, and clinically scalable fabrication methods are expected to play a key role in translating copper-containing surfaces from experimental concepts toward commercially viable soft-tissue biomedical devices.

Copper