Search PubMedSearch

SEARCH · Search PubMed

Results for “Technical complications”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

347 records · Page 2Linked to original sources

Triggering modalities to synchronise non-invasive respiratory support in preterm infants: a systematic review and meta-analysis.

BACKGROUND: Increasing evidence suggests that synchronised nasal intermittent positive pressure ventilation (sNIPPV) may be the optimal mode of non-invasive respiratory support. However, no comprehensive review of sNIPPV modes is available. This review aims to describe different synchronisation methods for sNIPPV and compare their effectiveness in clinical, physiological and technical outcomes with other modes of non-invasive respiratory support. METHODS: This review identified all clinical studies in preterm infants that compared sNIPPV to other non-invasive respiratory support modes or compared different trigger modalities between 1990 and 2026. A search was carried out in MEDLINE, Embase and the Cochrane Library. Main outcomes were categorised as clinical (eg, extubation failure (EF)), physiological (eg, breathing effort) and technical (eg, synchronisation rate). RESULTS: 49 studies (2864 infants) were included, with a low to moderate risk of bias. Meta-analysis showed a reduction in EF (risk ratio=0.38; 95% CI 0.17 to 0.85; p=0.03) in favour of sNIPPV compared with nasal continuous positive airway pressure (nCPAP). Physiological outcomes were significantly improved during sNIPPV compared with nCPAP and nasal intermittent positive pressure ventilation (NIPPV), especially breathing effort. When reviewing technical outcomes, non-invasive neurally adjusted ventilatory assist showed lower patient-ventilator asynchrony (PVA) (index ranging from 7% to 50%), a higher synchronisation rate (80%-99%) and a shorter trigger delay (35 ms) compared with other sNIPPV modes. CONCLUSIONS: This review shows that synchronising NIPPV results in consistent physiological (reduced patient effort) and technical benefits (reduced PVA). However, evidence on positive effects on (long-term) major clinical outcomes remains limited and requires further studies. PROSPERO REGISTRATION NUMBER: CRD420251022479.

Humans

Application of Three-Dimensionally Printed Surgical Guides in Precise Sacral Tumor Excision and Defect Reconstruction.

OBJECTIVE: Precise resection of sacral tumors remains technically demanding due to their deep anatomical location and close proximity to critical neurovascular structures. Conventional freehand techniques often result in suboptimal resection margins, excessive blood loss, and compromised lumbopelvic stability. This study evaluated whether patient-specific three-dimensional (3D)-printed guiding templates improve surgical accuracy and perioperative outcomes in sacral tumor resection and reconstruction. METHODS: Nineteen patients undergoing en bloc sacral tumor resection (S1-S3 involvement) with spinopelvic reconstruction (2006-2020) were retrospectively analyzed. Patients were divided into a 3D-printing group (n&#x2009;=&#x2009;10) and a conventional freehand group (n&#x2009;=&#x2009;9). In the 3D-printing group, computer-aided design and 3D-printed templates were used for osteotomy, screw placement, and defect reconstruction. Perioperative metrics, surgical accuracy, and complications were compared between groups using Welch's t-test and the Hodges-Lehmann method; oncologic events during follow-up were recorded descriptively. RESULTS: The 3D-printing group demonstrated significantly shorter operative time (456.5&#x2009;&#xb1;&#x2009;62.36 vs. 574.44&#x2009;&#xb1;&#x2009;114.58&#x2009;min, p&#x2009;=&#x2009;0.012), reduced blood loss (4081.40&#x2009;&#xb1;&#x2009;838.99 vs. 5090.0&#x2009;&#xb1;&#x2009;1059.67&#x2009;mL, p&#x2009;=&#x2009;0.034), and fewer fluoroscopic exposures (4.2&#x2009;&#xb1;&#x2009;0.79 vs. 10.0&#x2009;&#xb1;&#x2009;1.58, p&#x2009;<&#x2009;0.001) compared with the conventional group. Osteotomy accuracy was also superior in the 3D-printing group, with significantly lower angular deviation (3.33&#xb0;&#x2009;&#xb1;&#x2009;0.45&#xb0; vs. 6.79&#xb0;&#x2009;&#xb1;&#x2009;2.16&#xb0;, p&#x2009;=&#x2009;0.0012). Postoperative complication rates were comparable (30% vs. 44.4%, p&#x2009;=&#x2009;0.649), but hospital stay was significantly shorter in the 3D-printing group (10.7&#x2009;&#xb1;&#x2009;2.71 vs. 18.11&#x2009;&#xb1;&#x2009;4.01&#x2009;days, p&#x2009;<&#x2009;0.001). CONCLUSION: Patient-specific 3D-printed guiding templates enhance precision in sacral tumor excision and reconstruction, improving surgical efficiency and perioperative safety. This computer-assisted, template-guided approach represents a valuable advancement for complex sacral oncologic surgery.

Humans

The Effectiveness of Passive Half-Time Interventions on Simulated Second-Half Performance in Elite Youth Soccer Players.

The half-time period in soccer provides a potentially important window to implement short-duration interventions aimed at maintaining second-half performance. However, passive rest has been associated with a decline in subsequent physical and technical performance. While re-warm-up strategies are well studied, little is known about the efficacy of technology-based, passive recovery modalities, device-supported interventions that require minimal active movement or physical exertion from the athlete, during half-time intervals. This study examined whether percussive therapy, electrical muscle stimulation, and pneumatic compression can mitigate second-half performance decline in male adolescent soccer players. Forty-three academy-level players (17.5 &#xb1; 0.6 years) completed a simulated soccer protocol including the Loughborough Soccer Pass Test (LSPT), repeated 20-meter sprints, and completed Total Quality of Recovery (TQR) assessments before and after half-time. Participants were randomized into one of four intervention groups during the 15-minute half-time interval: Passive Rest (CON), Percussive Therapy (Theragun Pro; TG), EMS (PowerDot; PD), and Pneumatic Compression (RecoveryAir; COMP). Linear mixed-effects models assessed Time &#xd7; Condition interactions for performance and recovery outcomes. Passive half-time rest led to significant deterioration in technical skill, sprint performance, and perceived recovery (p < .05) for the control group. TG and PD significantly improved technical performance (LSPT scores) compared to the control group (d = 0.65 and 0.72, respectively; p < .01). Furthermore, TG and COMP were effective at maintaining 20-meter sprint times (d = 0.58 and 0.49; p < .01), whereas the control group experienced significant slowing. Perceived recovery (TQR) scores significantly declined in the CON group from First Half to Second Half (16.5 &#xb1; 2.2 to 11.1 &#xb1; 2.3. However, this decline was significantly attenuated in all intervention groups: TG (17.5 &#xb1; 1.9 to 14.2 &#xb1; 1.9), PD (17.3 &#xb1; 1.9 to 15.1 &#xb1; 1.9), and COMP (17.6 &#xb1; 1.9 to 15.9 &#xb1; 2.0). Short-duration passive interventions during half-time can mitigate performance decline in adolescent soccer players. TG and EMS appear most effective for preserving technical skills, while COMP may support perceived recovery. These findings highlight practical strategies for optimizing in-game performance and inform evidence-based half-time protocols.

Humans

Applications of artificial intelligence in robot-assisted surgery: a systematic review.

To characterize applications of artificial intelligence (AI) in robot-assisted surgery, summarize technical and clinical performance, and assess the quality of the available evidence. PubMed, Web of Science Core Collection, and Scopus were searched for English-language journal articles published from 1 January 2020 through 31 October 2025. Randomized, observational, model-development, validation, and feasibility studies evaluating AI in robot-assisted surgery or closely related image-guided minimally invasive workflows were eligible. Two reviewers independently performed study selection, data extraction, and risk-of-bias assessment. Owing to heterogeneity in surgical procedures, AI tasks, analytical units, validation strategies, and outcomes, findings were synthesized descriptively without statistical pooling. The review was registered in the International Prospective Register of Systematic Reviews (CRD420251175699). Seventeen studies were included: seven clinical prediction or decision-support studies, eight intraoperative recognition, segmentation, or image-guided studies, and two training or workflow studies. Five prediction studies reported area-under-the-curve values of 0.74-0.95. Technical studies reported F1 or Dice scores of 0.525-0.995 and task-specific accuracies of 0.840-0.998. Two randomized studies suggested benefits for personalized suturing feedback and automated camera control, but neither established improved patient outcomes. Only one study had low overall risk of bias; the remaining studies were at high or unclear risk or raised some concerns. AI applications in robot-assisted surgery show promise for prediction, intraoperative perception, training, and workflow support. Evidence primarily demonstrates technical feasibility rather than established clinical effectiveness. Independent multicenter validation and prospective evaluation of patient, educational, and workflow outcomes are required before widespread implementation.

Robotic Surgical Procedures

Getting to the Core of the Matter-Assessing the Role of Replication in Metabarcoding-Based sedaDNA.

Replication is central to most experimental and sampling designs, increasing inferential power and capturing fine-scale data heterogeneity. However, its importance remains poorly evaluated in some ecological and evolutionary settings. This is the case of metabarcoding studies using DNA recovered from sedimentary archives, in which biological signals integrate ecological information through depositional and burial processes, yet are commonly inferred from a single sediment core per site. Here, we evaluated the effect of different types of replication using sedimentary DNA metabarcoding data from two genetic markers (mitochondrial COI and nuclear 18S) using a nested sampling design. The design included three intertidal sites, three spatially separated sediment cores per site (biological replicates), two sediment horizons per core, and eight PCR (technical) replicates per sediment sample. Variance partitioning showed that site identity and sediment age group together explained >&#x2009;70% of the variation in beta diversity, indicating that among-site spatial and stratigraphic differences were the dominant drivers of community composition. PERMANOVA likewise identified non-significant effects of biological replication. Among PCR replicates from the same sediment sample, richness varied substantially, whereas Shannon diversity was more consistent. Despite this variability, differences in community composition among technical replicates remained smaller than those associated with biological replication or site identity, indicating a limited influence on broader ecological patterns. Community composition was highly similar among replicate cores within sites, consistent with stratigraphic coherence. These results indicate limited within-site heterogeneity and suggest that, under stratigraphically coherent conditions, increasing biological replication may provide little additional information, whereas enhancing technical replication and stratigraphic resolution can improve ecological inference from sedimentary DNA metabarcoding datasets.

DNA Barcoding, Taxonomic

Efficacy and safety of endoscopic ultrasound-guided choledochoduodenostomy compared with endoscopic ultrasound-guided gallbladder drainage for palliation of malignant distal biliary obstruction: a systematic review and meta-analysis.

BACKGROUND AND AIMS: When ERCP is not feasible or fails in the palliation of malignant distal biliary obstruction (MDBO), EUS-guided choledochoduodenostomy (EUS-CDS) and EUS-guided gallbladder drainage (EUS-GBD) are viable alternatives. We conducted a systematic review and meta-analysis comparing the safety and efficacy of the 2 techniques for the palliation of MDBO. METHODS: Multiple databases were searched through November 2025 for studies that reported outcomes of EUS-CDS and EUS-GDB in patients with MDBO. A meta-analysis was performed to determine pooled proportions and relative risk (RR) with 95% CIs. We compared the rates of technical and clinical success, overall adverse events (AEs), and lumen-apposing metal stent dysfunction. A random-effects model was used for our meta-analysis, and heterogeneity was assessed using the I2 (%) statistics. RESULTS: Five studies (352 patients; EUS-CDS: 193 and EUS-GBD: 159) were included. Technical success was 93.3% (95% CI, 70.6-98.8) for EUS-CDS and 95.9% (95% CI, 90.0-98.4) for EUS-GBD (RR, 1.02; 95% CI, 0.94-1.10; P = .6). Clinical success was 90.1% (95% CI, 84.7-93.7) versus 86.6% (95% CI, 80.3-91.0) (RR, 0.97; 95% CI, 0.90-1.05; P = .4). There were no significant differences in overall AEs (19.7% vs 17.6%; RR, 0.93; 95% CI, 0.58-1.48; P = .8), severe AEs (11.0% vs 8.3%; RR, 0.69; 95% CI, 0.33-1.44; P = .3), or stent dysfunction (15.0% vs 14.5%; RR, 0.95; 95% CI, 0.35-2.58; P = .9). CONCLUSIONS: EUS-GBD appears comparable to EUS-CDS in terms of technical and clinical success, AEs, and stent dysfunction. Further prospective studies are warranted to corroborate our findings.

Humans

Dual-Reporter Gene-Based Multimodal Imaging for Tracking Mesenchymal Stem Cells in Diabetic Skin Wound Repair.

BACKGROUND: Diabetic foot ulcer (DFU) is a clinically challenging complication characterized by poor healing outcomes, and conventional therapies provide limited benefit. Mesenchymal stem cell (MSC) transplantation offers a promising strategy for DFU repair. However, the low survival of transplanted MSCs in the hostile wound microenvironment, coupled with the lack of real-time, non-invasive methods to track these cells in vivo, severely hampers their therapeutic efficacy and clinical translation. METHODS: We engineered MSCs to co-express a dual reporter system comprising near-infrared fluorescent protein (iRFP) and ferritin heavy chain (FTH1). These modified cells were then integrated with a fibrin glue (FG) scaffold to create a unified platform that supports both multimodal imaging and therapeutic function within skin wounds. First, FTH1 overexpression enhances the antioxidant capacity of MSCs, while the FG scaffold provides structural support; this combination enhances cell survival and retention. Second, the iRFP/FTH1 dual reporter enables near-infrared fluorescence imaging and MRI-based localization, establishing a multimodal platform for real-time cell tracking. RESULTS: In a full-thickness skin defect model in diabetic mice, multimodal imaging revealed that transplanted cells persisted in the wound area for approximately seven days. Treatment with iRFP/FTH1-MSCs/FG significantly accelerated wound closure and promoted hair follicle regeneration and angiogenesis. Additionally, local iron deposition resulting from FTH1 expression enhanced fibroblast migration and collagen synthesis, further facilitating extracellular matrix remodeling. Mechanistic studies demonstrated that this therapy drives macrophage polarization toward the anti-inflammatory M2 phenotype and activates the PI3K-AKT-VEGF signaling pathway. These complementary effects synergistically enhance tissue regeneration and systematically improve diabetic wound healing. CONCLUSIONS: Collectively, this multimodal stem cell-scaffold system effectively integrates dynamic cell tracking with stem cell therapy during skin wound repair. It addresses a critical technical gap in visualizing stem cells within the wound microenvironment and provides valuable methodological and theoretical foundations for optimizing regenerative strategies for diabetic skin wounds.

Animals

Comparative efficacy and safety of bi-flanged metal stents versus lumen-apposing metal stents for endoscopic drainage of pancreatic fluid collections: a systematic review and meta-analysis.

INTRODUCTION: Pancreatic fluid collections (PFCs), particularly walled-off necrosis, are common complications of acute pancreatitis that often require endoscopic drainage. Bi-flanged metal stents (BFMS; NAGI; Taewoong Medical, Gyenoggi-do, Korea) and electrocautery-enhanced lumen-apposing metal stents (LAMS; AXIOS, Boston Scientific Corporation, Marlborough, Massachusetts, USA) are frequently used, but comparative data remain limited. This study aims to compare the efficacy and safety of BFMS and LAMS in the endoscopic drainage of PFCs. METHODS: This meta-analysis followed the Cochrane Handbook for Systematic Reviews of Interventions and Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Comprehensive database searches were conducted through November 2024 to identify studies comparing BFMS and LAMS for endoscopic ultrasound-guided drainage of PFCs. Outcomes were pooled using a random-effects model with RevMan Web, and statistical significance was defined as a P value less than 0.05. RESULTS: Three studies ( n &#x2005;=&#x2005;627; 329 BFMS and 298 LAMS) met inclusion criteria. No significant differences were observed between BFMS and LAMS for technical success [odds ratio (OR): 1.16; 95% confidence interval (CI): 0.55-2.43] or clinical success (OR: 0.97; 95% CI: 0.51-1.87). Similarly, there were no differences in walled-off necrosis recurrence (OR: 2.01; 95% CI: 0.17-24.02), number of direct endoscopic necrosectomy sessions (OR: 0.52; 95% CI: 0.05-5.12), or mean number of endoscopic procedures (mean difference: 0.18, 95% CI: 2.08-2.45). Adverse events were also comparable between groups, including bleeding (OR: 0.64), infection (OR: 1.18), stent migration (OR: 1.83), and stent occlusion/dysfunction (OR: 1.71). CONCLUSION: BFMS and LAMS provide equivalent efficacy and safety in the endoscopic ultrasound-guided drainage of PFCs. Either stent type represents a viable therapeutic option. Further large-scale prospective studies are warranted to refine stent selection strategies.

Humans

Virtual, Augmented, and Mixed Reality Technologies in Neurosurgical Training: Enhancing Skills and Surgical Outcomes: A Systematic Review.

OBJECTIVE: To systematically review the role of virtual reality (VR), augmented reality (AR), and mixed reality (MR) in neurosurgical education and training. DESIGN: Systematic review conducted in accordance with the PRISMA guidelines. SETTING: A comprehensive search was performed across PubMed/MEDLINE, Scopus, Web of Science, and Google Scholar for English-language studies published between 1 January 2020 and 30 April 2026. PARTICIPANTS: Studies involving neurosurgeons, fellows, residents, and medical students (maximum sample size: n = 48) were included. RESULTS: Of 7,204 initially identified studies, 25 met the inclusion criteria. VR was primarily used for surgical simulation (100% of VR studies) and anatomical education (62.5%). AR demonstrated broader applications, including preoperative planning (40%) and intraoperative support (30%). MR was evenly distributed across simulation, planning, and intraoperative support (40% each). The most frequently improved outcomes were training effectiveness (52%) and technical proficiency (44%). Methodological quality scores, assessed using the Modified Medical Education Research Study Quality Instrument (MMERSQI), ranged from 39.5 to 84.5, indicating varied rigor. CONCLUSION: VR, AR, and MR technologies show potential to enhance surgical precision, technical skills, and educational outcomes in neurosurgical training. However, standardization of methodologies and cost-effective solutions remain essential. Future research should focus on long-term clinical impact and integration of AI-driven training models.

Virtual Reality

Gelified ethanol for percutaneous sclerotherapy of bone lesions: a systematic review of clinical applications and outcomes.

PURPOSE: To systematically review the available evidence on the feasibility, safety, and clinical effectiveness of percutaneous sclerotherapy using radiopaque gelified ethanol (RGE, Discogel&#xae;) for bone lesions. METHODS: A systematic search of MEDLINE, Embase, Web of Science, and Cochrane CENTRAL was performed. Primary studies reporting clinical, technical, and safety outcomes following RGE sclerotherapy for bone lesions were included. Data on patient characteristics, lesion type, procedural details, and outcomes were extracted and synthesized descriptively. RESULTS: Six retrospective studies involving 55 patients (mean age 22.2&#x2009;&#xb1;&#x2009;20.4&#xa0;years; range 3-65; 26 females) with 56 lesions and 119 procedures were included (mean 2.16 procedures per patient). Aneurysmal bone cysts (80%) and aggressive vertebral hemangiomas (18%) were the main indications. Technical success was reported in 100% of procedures. Pain outcomes were available for 28 patients, with complete resolution in 64.3% (18/28), partial reduction in 32.1% (9/28), and persistence in 3.6% (1/28). Radiological follow-up (50 lesions) demonstrated complete response in 96% and partial response in 4%. No major adverse events were reported according to CIRSE (&#x2265;&#x2009;4) or CTCAE (&#x2265;&#x2009;4) criteria. One SIR grade 3 vertebral fracture occurred without confirmed causal association to RGE. Subsequent surgery was required in 3.6% of lesions. CONCLUSION: Although limited to small retrospective series, current evidence suggests that RGE sclerotherapy is a safe and effective minimally invasive option for selected benign bone lesions. Prospective comparative studies with longer follow-up are warranted.

Humans

Endoscopic Ultrasound-Guided Versus Transjugular Portal Pressure Measurements: Systematic Review and Meta-Analysis.

PURPOSE: Published reviews of endoscopic ultrasound-guided portal pressure gradient (EUS-PPG) have emphasized feasibility and safety. We performed a systematic review and meta-analysis specifically to evaluate how closely EUS-based portal pressure measurements track invasive comparator measurements in prospective paired studies and to summarize agreement, technical success, and adverse events. METHODS: We searched major databases through January 2026 for prospective cohorts reporting same-patient EUS-based portal pressure measurement and invasive hemodynamic measurements. Correlations were pooled with random-effects models and analyzed separately for studies comparing EUS-PPG with hepatic venous pressure gradient (HVPG) and studies comparing EUS-based portal measurements with direct portal venous pressure. Agreement and threshold discordance were summarized descriptively. RESULTS: Six prospective cohorts (127 attempted procedures) were included. In studies using HVPG as the comparator, the pooled correlation was 0.82 (95% CI, 0.72-0.89; I2&#x2009;=&#x2009;0%). In studies comparing EUS-based portal measurements with direct portal venous pressure, the pooled correlation was 0.86 (95% CI, 0.72-0.93; I2&#x2009;=&#x2009;16.9%). Technical success was 95.3%. EUS-PPG-attributed adverse events occurred in 2.4% of procedures, with no procedure-related deaths. Agreement data were limited. Reported limits of agreement were wide (approximately -&#xa0;6 to&#x2009;+&#x2009;7&#xa0;mmHg), and discrepancies of 5&#xa0;mmHg or greater occurred in 4 of 30 paired measurements. CONCLUSIONS: EUS-based portal pressure measurement is feasible and shows a strong association with invasive hemodynamic comparators, but the evidence base remains small (six cohorts, 127 attempted procedures). Further study will be necessary to establish patient-level agreement, procedural reproducibility, EUS-specific clinically significant portal hypertension thresholds, and whether HVPG-based decision thresholds can be transferred to EUS-derived measurements.

Humans

Associations between smart infusion pump-electronic health record interoperability and healthcare outcomes: A systematic review.

OBJECTIVE: This study synthesized available evidence on the associations between smart infusion pump-electronic health record (EHR) interoperability and healthcare outcomes. METHODS: A systematic review of PubMed, CINAHL, Embase, and Scopus databases identified 901 records, which were imported into Rayyan&#xae; for duplicate removal, independent screening by three reviewers, and resolution of discrepancies. Eligible studies were peer-reviewed, data-driven, and reported associations between smart infusion pump-EHR interoperability and healthcare outcomes. Studies focused solely on technical validation or interoperability prototypes were excluded. A backward citation search identified additional studies. Two reviewers independently extracted and cross-validated study characteristics using standardized templates. Methodological quality was assessed with the Joanna Briggs Institute Critical Appraisal Tools. RESULTS: Twenty records of 14 full-text studies and 6 conference proceedings were included. Most records reported positive associations between smart infusion pump-EHR interoperability and outcomes related to safety (e.g., medication administration errors, safety-reported events, pump alerts, and compliance with interoperability and drug library), operational efficiency (e.g., programming and documentation time and technical issues), financial performance (e.g., charges captured, and cost avoided), and user experience domains. Most studies used observational designs, reflecting real-world interoperability implementations, where controlling confounding factors is challenging. Limited reporting of baseline characteristics, pump type, and sample sizes limited comparability across studies. CONCLUSIONS: Smart infusion pump-EHR interoperability was associated with improvements in patient safety, efficiency, charge capture, and user experience, with variable findings across studies. Future research should use rigorous methodologies and standardized measures, examine relationships across outcome domains, assess limitations of pump-EHR interoperability, and evaluate underexplored outcomes, including team communication, cognitive workload, and AI-enabled pumps. IMPLICATIONS FOR CLINICAL PRACTICE: Interoperability should be viewed as a component of a broader sociotechnical system, in which technology, user, workflow, clinical content, and organizational practices collectively determine overall effectiveness.

Humans

Quo vadis, BGA? A collaborative EDNAP exercise on the challenges and progress in forensic biogeographical ancestry inference.

There is a broad consensus that forensic tests for the prediction of externally visible characteristics (EVC) and analysis of biogeographic ancestry (BGA) of an individual are technically reliable. However, interpretation of the results and population-specific genotype distribution patterns remains challenging. EVC and BGA analyses provide valuable information for population genetics studies and as investigative leads for criminal cases, as well as for historical and contemporary identification tests. However, inaccurate or incorrect predictions, for example, from subjective bias in the interpretations made, have the potential to misdirect police investigations. The legal situation regarding EVC and BGA testing varies by country: ranging from countries where it is explicitly prohibited, to those without specific regulations on biogeographic ancestry prediction, and others that have already enacted laws governing its use. The reluctance to utilize these analyses is not only due to legal restrictions and data protection concerns, but also to initial limited sets of sufficiently comprehensive forensic DNA assays. Forensic BGA marker panels typically contain up to &#x223c;300 SNPs. This relatively small number of genetic markers, along with limited reference population data, complicates the interpretation of results from donors of unknown origin. This paper presents the results of a collaborative EDNAP study, which, for the first time, evaluated the approach to reporting EVC and BGA data between international laboratories. For the study, DNA from nine individuals with self-reported ancestry was collected and analysed using various forensic panels differing in the number and composition of ancestry-informative markers genotyped, comprising: the Precision ID mtDNA Whole Genome Panel, the VISAGE Basic Tool and the VISAGE Enhanced Tool for Appearance and Ancestry Prediction, and the Ion AmpliSeq&#x2122; PhenoTrivium Panel. To ensure full data protection, all SNP genotypes and uniparental marker haplotypes obtained were not shared with third parties. Instead, the genetic data were analysed using a range of commonly used population analysis software packages. These analysis outcomes were then distributed to twelve European forensic laboratories (both academic and law enforcement institutions), who were asked to prepare reports based on their interpretation of the phenotypes and ancestry they inferred from the analysis data. A questionnaire sent alongside the genetic information, aimed to evaluate which difficulties were encountered by the participants in processing the BGA analysis data they were given.

Humans

Robot-assisted versus manual percutaneous vascular interventions across vascular territories: a systematic review and meta-analysis.

Robot-assisted percutaneous vascular intervention (R-PVI) has expanded beyond coronary procedures, but previous reviews were largely coronary-focused and observational. Recent randomized controlled trials (RCTs) warrant broader reassessment of R-PVI versus manual percutaneous vascular intervention (M-PVI) across vascular territories. PubMed, Embase, Web of Science, and the Cochrane Central Register of Controlled Trials were searched from database inception to January 31, 2026, following PRISMA guidelines. RCTs and observational studies including &#x2265;10 adult patients in total were eligible. Comparative studies informed primary analyses, while single-arm studies provided supportive evidence. Primary outcomes were clinical success rate and major adverse cardiovascular/cerebrovascular events (MACE) rate. Secondary outcomes included mortality rate, technical success rate, procedural time metrics, contrast volume, and radiation exposure. Random-effects models were used. Forty studies were included: 3 RCTs, 10 comparative observational studies, and 27 single-arm observational studies, comprising 3,870 patients undergoing R-PVI and 1,142 undergoing M-PVI. Comparative analyses showed similar clinical success rates (RR 1.00, P = 0.46), MACE rates (RR 0.72, P = 0.43), and mortality. Single-arm pooled estimates for clinical and technical success were 98.76% and 96.09%, respectively. R-PVI prolonged total procedure time overall (MD 15.92&#xa0;min, P = 0.01), with consistent increases in the neurovascular, RCT, and non-RCT subgroups. Fluoroscopy time was also longer (MD 1.91&#xa0;min, P = 0.04), mainly in the RCT subgroup (MD 2.83&#xa0;min, P = 0.001). In contrast, intravascular intervention time was unchanged overall and in RCTs, but was prolonged in non-RCTs (MD 8.72&#xa0;min, P = 0.006). Operator radiation exposure was markedly reduced (MD -33.97 &#x3bc;Sv, P < 0.001), whereas patient radiation exposure and contrast volume were similar. R-PVI appears feasible and safe across selected vascular procedures. Its clearest benefit is reduced operator radiation exposure, whereas lower whole-procedure efficiency remains its main limitation.

Humans

A dual-dimensional CRISPR toolkit enables one-step high-efficiency multiplex genome editing in Komagataella phaffii.

Against the backdrop of green biomanufacturing, engineering methanol-utilizing Komagataella phaffii (K. phaffii) represents an effective strategy to expand the one carbon (C1) product profile and speed up the industrialization of C1-based bioeconomy. To address the technical challenges of low efficiency and cumbersome experimental procedures for multiplex gene editing and precise large-fragment integration during the reconstruction of complex metabolic pathways in K. phaffii, this study established a CRISPR toolkit - Efficient Multi-Gene Editing System 3.0 (EMGES 3.0) - which enabled one-step large-fragment integration coupled with multiplex gene knockout. EMGES 3.0 was constructed through the synergistic optimization of a repair-engineered chassis and an episomal CRISPR vector. For chassis engineering, five DNA repair modules: &#x394;lig4 (DNA Ligase IV, non-homologous end joining end ligation), ppMRE11(The endogenous MRE11 gene from Pichia pastoris) overexpression (The Meiotic Recombination 11, DNA double-strand break end resection), &#x394;rad9 (Radiation-Sensitive 9, DNA damage checkpoint regulation), &#x394;mph1 (Mutator Phenotype Helicase 1, improvement of homologous recombinant strand extension), and PapRecT-PaSSB co-expression (stabilization of recombination intermediates) were integrated to generate the highly recombinogenic strain Y09. For vector engineering, cenARS was replaced by panARS and the endogenous promoter PGAP was employed to drive the double hammerhead ribozyme-single guide RNA-hepatitis delta virus ribozyme (double HH-sgRNA-HDV: dHgH)-mediated sgRNA expression, yielding the optimized vector Nov_pGAP_panARS_pLAT1_Cas9. These two features on K. phaffii together enhanced the EMGES 3.0 to a higher standard of transformation rate and editing efficiency. According to our results, EMGES 3.0 achieved dual-functional gene knockout efficiencies between 76.6% and 100%. For insertion of medium-long fragments (>4.5&#x202f;kb), the efficiency achieved 93.3%. In addition, the one-step integration of ultra-long fragments (>16&#x202f;kb) achieved 14.8%, which was reported for the first time. Furthermore, the efficiency of simultaneous long-fragment integration at three neutral loci reached 38.4% (>15&#x202f;kb). We applied the system for one-step production of free fatty acids (FFAs, yield: 5.82 &#x223c; 7.30&#x202f;mg/L/OD600) and resveratrol (yield: 1.14 &#x223c; 1.28&#x202f;mg/L) using methanol as the sole carbon source. EMGES 3.0 provides a robust technical foundation for complex compounds biosynthesis and high-yield industrial strains, while also advancing K. phaffii as an industrial synthetic biology chassis for efficient C1 utilization.

CRISPR-Cas Systems

Rare clinical complications following scorpion envenomation worldwide: A systematic review.

Scorpion envenomation is an important public health problem in many tropical and subtropical regions and may result in rare but life-threatening grade III complications involving multiple organ systems. This systematic review synthesizes published articles from 2000 to 2025 that describe uncommon, severe clinical manifestations following scorpion stings. A total of 71 rare clinical complications were identified, encompassing cardiovascular, neurological, respiratory, renal, hematological, ocular, dermatological, and other systemic manifestations. Cardiovascular complications were the most frequently reported, whereas neurological complications exhibited the greatest clinical diversity. Mesobuthus tamulus and Hemiscorpius lepturus were most commonly associated with severe complications, and children younger than 10 years appeared to be at increased risk of serious neurological involvement. These findings highlight the remarkable clinical heterogeneity of grade III scorpion envenomation and emphasize the importance of early recognition, species-specific clinical awareness, and timely management to reduce severe outcomes in endemic regions.

Humans

The Neurological Impact of Metabolic and Bariatric Surgery: A Systematic Review of Post-Operative Neuropathic and Non-Neuropathic Complications.

Metabolic and bariatric surgery achieves durable weight loss and meaningful improvement in obesity-related comorbidities yet carries a risk of neurological complications that remains under-recognised in routine clinical practice. This systematic review, registered with PROSPERO (CRD42024591611) and conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses 2020 guidelines, searched MEDLINE, Embase, Emcare, CINAHL and Cochrane databases through September 2023 to evaluate the incidence, spectrum, timing, pathophysiology and management of post-operative neurological complications. Twelve studies comprising over 5000 patients were included. Reported incidence ranged from 1.4% to 16%, with peripheral neuropathy the most frequent manifestation. Mononeuropathies, particularly carpal tunnel syndrome, were prominent in several cohorts, while central complications including Wernicke encephalopathy occurred less commonly but with considerably greater severity. Thiamine deficiency was the predominant aetiological factor. Onset varied from days to several years postoperatively, with early presentations typically compression-related and later ones nutritionally mediated. Outcomes were generally favourable with early intervention, though severe or delayed cases were associated with persistent neurological deficits and occasional mortality. Neurological complications after bariatric surgery are heterogeneous and largely preventable, and structured post-operative follow-up with consistent adherence to nutritional supplementation remains central to reducing long-term harm.

Humans

Is There a Difference in Occurrence of Complications Between Adults With Hemoglobin SS and Hemoglobin SC Disease: An Extended Systematic Review.

Sickle cell disease (SCD) is characterized by both acute and chronic complications. The clinical manifestation of these complications differs between genotypes. Given the large amount of research already published, this systematic review aims to offer a complete overview of types of sickle cell complications between adults in the most common genotypes Hemoglobin SS (HbSS) and Hemoglobin SC (HbSC), putting options for further research into perspective. An extensive literature search was performed to study all available evidence on these complications. This review was performed according to the "Preferred Reporting Items for Systematic Reviews and Meta-Analyses" (PRISMA) statement guidelines, and was performed on January 2, 2024. A total of 710 references were identified. After careful screening, 521 records were excluded based on title and abstract and other exclusion criteria. In total, 158 articles were excluded after full-text assessment. Our analysis of 31 studies highlights key differences in complications between HbSS and HbSC genotypes in sickle cell disease (SCD). Vaso-occlusive crises (VOCs) remain the most common acute complication in both genotypes. HbSS patients experience more frequent VOCs, while HbSC patients generally have a milder clinical course when it comes to acute complications. Chronic complications, particularly in the ocular and pulmonary systems, are more prevalent in HbSC patients. However, as acute complications are more common in HbSS and chronic complications more common in HbSC, both genotypes face progressive organ damage due to recurrent ischemic injury and inflammation.

Humans