Search PubMedSearch

SEARCH · Search PubMed

Results for “Ocular Hypertension”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

68 records · Page 2Linked to original sources

Endoscopic Ultrasound-Guided Versus Transjugular Portal Pressure Measurements: Systematic Review and Meta-Analysis.

PURPOSE: Published reviews of endoscopic ultrasound-guided portal pressure gradient (EUS-PPG) have emphasized feasibility and safety. We performed a systematic review and meta-analysis specifically to evaluate how closely EUS-based portal pressure measurements track invasive comparator measurements in prospective paired studies and to summarize agreement, technical success, and adverse events. METHODS: We searched major databases through January 2026 for prospective cohorts reporting same-patient EUS-based portal pressure measurement and invasive hemodynamic measurements. Correlations were pooled with random-effects models and analyzed separately for studies comparing EUS-PPG with hepatic venous pressure gradient (HVPG) and studies comparing EUS-based portal measurements with direct portal venous pressure. Agreement and threshold discordance were summarized descriptively. RESULTS: Six prospective cohorts (127 attempted procedures) were included. In studies using HVPG as the comparator, the pooled correlation was 0.82 (95% CI, 0.72-0.89; I2 = 0%). In studies comparing EUS-based portal measurements with direct portal venous pressure, the pooled correlation was 0.86 (95% CI, 0.72-0.93; I2 = 16.9%). Technical success was 95.3%. EUS-PPG-attributed adverse events occurred in 2.4% of procedures, with no procedure-related deaths. Agreement data were limited. Reported limits of agreement were wide (approximately - 6 to + 7 mmHg), and discrepancies of 5 mmHg or greater occurred in 4 of 30 paired measurements. CONCLUSIONS: EUS-based portal pressure measurement is feasible and shows a strong association with invasive hemodynamic comparators, but the evidence base remains small (six cohorts, 127 attempted procedures). Further study will be necessary to establish patient-level agreement, procedural reproducibility, EUS-specific clinically significant portal hypertension thresholds, and whether HVPG-based decision thresholds can be transferred to EUS-derived measurements.

Humans

Obstructive sleep apnea and idiopathic intracranial hypertension: a systematic review and meta-analysis.

OBJECTIVE: To determine the pooled prevalence of obstructive sleep apnea (OSA) among adults with idiopathic intracranial hypertension (IIH) using polysomnography (PSG) and the Berlin Questionnaire screening. NATURE: IIH is a vision-threatening disorder characterized by elevated intracranial pressure. OSA shares overlapping risk factors and pathophysiological mechanisms with IIH, including nocturnal hypoxia and hypercapnia. Clarifying OSA prevalence in IIH is clinically important for diagnosis and management. METHODS: For this prospectively registered systematic review and meta-analysis (PROSPERO: CRD420251132794), we searched MEDLINE, Embase, and CENTRAL from inception to August 23, 2025, for studies reporting PSG-confirmed OSA or Berlin Questionnaire positivity in adults with IIH. Risk of bias was assessed using ROBINS-I and RoB-2, and certainty of evidence was checked using the Grading of Recommendations, Assessment, Development and Evaluation tool. Random-effects meta-analyses of proportions generated pooled prevalence estimates. Subgroup analyses excluded high-risk studies, leave-one-out analyses assessed robustness, and funnel plots evaluated publication bias. RESULTS: Eleven studies met the inclusion criteria. Across 9 PSG-based studies (n = 299), the pooled prevalence of OSA in IIH was 0.44 (95% CI: 0.26-0.63; I² = 90.5%). Leave-one-out analyses showed stable results (39%-50%). Excluding high-risk studies (4 studies; n = 132) yielded a pooled prevalence of 0.53 (95% CI: 0.32-0.74). Four Berlin Questionnaire studies (n = 154) showed a pooled prevalence of 0.65 (95% CI: 0.54-0.74; I² = 0%). Funnel plot asymmetry suggested publication bias, and certainty of evidence was very low. CONCLUSIONS: OSA is common among patients with IIH, supporting routine objective sleep evaluation. Prospective studies are needed to clarify this association.

Humans

Postoperative hypotony after retinectomy in rhegmatogenous retinal detachment surgery: A systematic review and meta-analysis.

We estimate the incidence of postoperative hypotony after retinectomy performed during rhegmatogenous retinal detachment surgery and explore clinical, surgical, and methodological factors associated with hypotony risk. We include human clinical studies reporting postoperative intraocular pressure (IOP) outcomes after retinectomy or retinotomy for retinal detachment. Postoperative hypotony was defined as IOP ≤ 6 mmHg, with alternative thresholds (≤5 or ≤3 mmHg) retained for sensitivity analyses. A random-effects meta-analysis was used to pool hypotony incidence, with prespecified subgroup and sensitivity analyses according to retinectomy extent, tamponade strategy, hypotony definition, assessment timepoint, and vitrectomy gauge size. Study-level associations with visual outcomes and proliferative vitreoretinopathy (PVR) severity were also explored. Thirty-three studies comprising 2673 eyes were included. The pooled incidence of postoperative hypotony was 13.71% (95% CI, 10.40-17.40), with substantial heterogeneity (I² = 83.2%). Hypotony incidence did not increase linearly with retinectomy extent, and similar rates were observed for extents of 180°-269° and ≥ 270°. Stricter hypotony definitions and later postoperative assessment timepoints were associated with a higher reported incidence. A significant negative association was observed between hypotony incidence and visual improvement rates (Spearman ρ = -0.47, p = 0.03). In contrast, no significant study-level difference in hypotony incidence was observed according to PVR severity grouping or vitrectomy gauge size. Postoperative hypotony after retinectomy is a frequent and clinically relevant complication, moderately associated with poorer visual outcomes and influenced by methodological factors rather than retinectomy extent alone.

Humans

Axial Length Adjustment and AL/R Ratio Optimization of IOL Power Calculation in Extremely Long Eyes.

PURPOSE: To evaluate the accuracy of modern intraocular lens (IOL) power calculation formulas and axial length (AL) adjustment methods in eyes with AL ≥ 30.0 mm. DESIGN: Retrospective consecutive cross-sectional study. PARTICIPANTS AND CONTROLS: A total of 308 eyes (308 patients) with AL ≥ 30.00 mm were included. METHODS: Accuracy of modern online formulas, alone or with established AL adjustments methods, was analyzed. Subgroup analyses were performed based on AL, keratometry (K), anterior chamber depth (ACD), lens thickness (LT), and AL-to-corneal radius (AL/R) ratio. MAIN OUTCOME MEASURES: Predictive accuracy was evaluated using the formula performance index (FPI), root mean square absolute prediction error (RMSAE), standard deviation (SD) of prediction error (PE), and percentage of eyes within ±0.25 and ±0.50 diopters (D). RESULTS: Overall, Holladay 1 combined with the nonlinear polynomial Wang-Koch axial length adjustment (H1-PWK) demonstrated the best overall performance, achieving the lowest SD (0.40), RMSAE (0.40), and highest FPI (0.494). A tendency toward hyperopic error was observed in eyes with AL ≥ 32.0 mm, K ≥ 46.0 D. The AL/R ratio showed a significant positive correlation with PE in the Ladas Super formula, Barrett Universal II, EVO, PEARL-DGS, and Hoffer QST formulas. Spline-based regression analysis indicated that the transition point of AL/R from myopic to hyperopic PE varied across different formulas. CONCLUSIONS: H1-PWK provides robust refractive accuracy in extremely long eyes. The AL/R ratio may provide a useful composite biometric stratification parameter compared to AL alone.

Humans

Intraocular pressure-lowering effects of tetrahydrocannabinol drugs: a systematic review and meta-analysis.

PURPOSE: Within the past few decades, several studies have reported intraocular pressure (IOP)-lowering effects associated with tetrahydrocannabinol (THC) compounds as an alternative or complementary agent to conventional glaucoma therapies. The purpose of this study is to generate pooled estimates on the IOP-lowering effects of THC. METHODS: This systematic review and meta-analysis article was registered a priori on PROSPERO (CRD420251007916). MEDLINE, EMBASE, and Web of Science were searched for studies reporting IOP reduction following THC administration. Two reviewers independently performed screening, data extraction, and risk of bias assessments. A random-effects meta-analysis of mean differences was performed to estimate the overall pooled peak percentage reduction in IOP following THC administration, stratified by route of THC administration. RESULTS: Five studies were included, consisting of a total of 99 patients and 69 with THC exposure/intervention. Overall, the pooled peak percentage reduction in IOP after THC administration was 14.66% (95% CI: [3.38%, 25.93%]; p < 0.005). By route of THC delivery, the pooled peak percentage reduction in IOP was 33.27% (95% CI: [20.36%, 46.17%]; p < 0.0001) with the IV route. It was 10.65% (95% CI: [-7.60%, 28.89%]) with the oral route and 9.36% (95% CI: [-8.89%, 27.6%]) with the topical route. Four studies reported the peak percentage reduction in IOP after THC and control administration. From these studies, the pooled peak percentage reduction in IOP after THC was 6.88% (95% CI: [-9.56%, 23.33%]; p&#x202f;=&#x202f;0.41) and nonsignificantly different from control. CONCLUSIONS: Our study generated literature-pooled estimates of the overall and route-stratified peak percentage reduction in IOP following THC administration. THC significantly reduced IOP, although comparatively less significant to the control group.

Humans

Risk Factors and Predictive Model for Postoperative High Myopia in Children Undergoing Congenital Cataract Surgery With Intraocular Lens Implantation.

PURPOSE: To identify risk factors associated with the development of high myopia following congenital cataract surgery and to establish a robust predictive model. DESIGN: Retrospective clinical cohort study. SUBJECTS: This retrospective study included 106 pediatric patients who underwent congenital cataract surgery with primary IOL implantation (mean follow-up 8.19 years). The model was externally validated in an independent cohort of 72 patients with a mean follow-up of 7.83 years. METHODS: Preoperative and postoperative ocular biometric parameters were collected. Risk factors for postoperative high myopia were analyzed using Cox proportional hazards regression, which served as the basis for model construction. The predictive performance of the model was rigorously evaluated for discrimination and calibration. Discriminative ability was quantified using Harrell's C-index and the area under the receiver operating characteristic curve (AUC). Model calibration was assessed via calibration plots by comparing predicted probabilities with actual observed outcomes. Internal validation was performed using a bootstrapping method (500 iterations) to ensure model stability and adjust for potential overfitting. RESULTS: An initial postoperative refraction of <+0.75D, and a higher IOL Power to Axial length Ratio (IOL/AL ratio) were identified as significant risk factors for the development of postoperative high myopia. Shorter preoperative axial length was associated with a greater magnitude of postoperative myopic shift. The predictive model demonstrated robust performance, achieving a C-index of 0.711 (internal validation C-index: 0.713). The area under the receiver operating characteristic curve (AUC) values for predicting high myopia at 5 and 10 years were 0.858 and 0.745, respectively. Furthermore, calibration curves demonstrated excellent agreement between the predicted and observed outcomes throughout the follow-up period. In external validation, the model achieved a C-index of 0.825, 5-year AUC of 0.833, and 10-year AUC of 0.713. CONCLUSIONS: Our analysis established that initial postoperative refraction <+0.75D, and an elevated IOL/AL ratio are key determinants of high myopia risk following surgery. Shorter preoperative axial length was associated with a greater magnitude of postoperative myopic shift. This predictive framework provides clinicians with a practical tool to optimize preoperative IOL selection and identify high-risk infants who require vigilant myopia prevention and balanced amblyopia management.

Humans

Discovery and characterization of multifunctional bioactive peptides from Alaska Pollock (Gadus chalcogrammus) milt: hybrid in silico, in vitro, and proteomic approaches.

The growing demand for multifunctional bioactive peptides has sparked interest in underutilized marine by-products as sustainable bioresources. This study explored Alaska Pollock (Gadus chalcogrammus) milt protein as a novel source of peptides with anti-inflammatory, anti-hypertensive, and anti-diabetic effects. Protein composition was analyzed via LC-MS, followed by in silico digestion and bioactivity prediction. Molecular docking identified peptides targeting DPP-IV, &#x3b1;-glucosidase, ACE, GLP-1 receptor, COX-2, MuRF1, and the 20S proteasome. Among the candidates, a promising peptide (CLPPH) was synthesized and validated in vitro, demonstrating inhibitory effects on nitric oxide production, DPP-IV, ACE, and &#x3b1;-glucosidase. These results highlight CLPPH's potential as a multifunctional bioactive peptide and support the valorization of Alaska Pollock milt as a sustainable source for functional foods and nutraceutical applications.

Animals

Astigmatic vector outcomes after FS-LASIK versus SMILE for high myopic astigmatism: a single-center retrospective comparative cohort study without cyclotorsion compensation.

PURPOSE: To compare astigmatic correction vector outcomes between femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and small-incision lenticule extraction (SMILE, also termed Keratorefractive Lenticule Extraction, KLEx) without intraoperative cyclotorsion compensation in patients with high myopic astigmatism (-&#x2009;2.00 to&#x2009;-&#x2009;3.75 D), and to clarify procedure-specific correction tendencies under this non-standardized alignment protocol. METHODS: This single-center retrospective comparative cohort study enrolled 155 eyes (one eye randomly selected per patient) that underwent FS-LASIK (80 eyes) or SMILE/KLEx (75 eyes) for high myopic astigmatism correction from January 2023 to July 2024 in Beijing Fenglian Jiayue Lige Clinic. Intraoperative cyclotorsion compensation was intentionally disabled to isolate inherent procedural astigmatism correction characteristics. Standardized Alpins vectorial analysis was performed at 3&#xa0;months and 12&#xa0;months postoperatively. PRIMARY ENDPOINT: 12-month Alpins correction index (CI). Multivariable propensity score adjustment was applied to mitigate confounding by clinical treatment selection bias. Statistical multiplicity control was implemented for secondary vector and visual outcomes. RESULTS: Baseline demographic, refractive, corneal and ocular biometric parameters were balanced between groups after propensity matching. No statistically significant intergroup differences were detected in uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), residual cylinder, safety index or efficacy index at 3 and 12&#xa0;months (all P&#x2009;>&#x2009;0.05). Under the non-cyclotorsion-compensated protocol, significant intergroup differences were identified in the magnitude of surgically induced astigmatism (SIA), correction index (CI), and magnitude error (ME) at both follow-up timepoints (all P&#x2009;<&#x2009;0.0001). Target induced astigmatism (TIA), difference vector (DV), index of success (IOS), and angle error (AE) magnitudes were comparable between groups (all P&#x2009;>&#x2009;0.05). The vector mean axis of DV differed significantly between groups at 3 and 12&#xa0;months (Watson-Williams circular test, all P&#x2009;<&#x2009;0.0001). No reoperations were documented in clinic medical records for either cohort. No standardized dry eye questionnaires, tear film testing or corneal nerve density metrics were collected to quantify dry eye adverse events; only unstructured clinical notes were reviewed for complication screening. CONCLUSIONS: Under surgical alignment without cyclotorsion compensation, FS-LASIK and SMILE/KLEx both yielded acceptable visual and refractive safety/efficacy for high myopic astigmatism (-&#x2009;2.00 to&#x2009;-&#x2009;3.75 D) at 1-year follow-up, but demonstrated divergent astigmatism correction tendencies: FS-LASIK exhibited relative astigmatism overcorrection (vector mean DV:&#x2009;-&#x2009;0.35&#x2009;&#xb1;&#x2009;0.43 D&#x2009;&#xd7;&#x2009;91&#xb0;, CI&#x2009;>&#x2009;1), while SMILE/KLEx showed relative undercorrection (vector mean DV:&#x2009;-&#x2009;0.21&#x2009;&#xb1;&#x2009;0.53 D&#x2009;&#xd7;&#x2009;12&#xb0;, CI&#x2009;<&#x2009;1). These correction biases are specific to the study's manual limbal alignment protocol without cyclotorsion tracking and cannot be generalized to modern optimized surgical platforms equipped with automated cyclotorsion compensation. Residual refractive errors across both groups are likely multifactorial, including differential corneal stromal healing responses, divergent femtosecond/excimer laser tissue modification mechanisms, and uncorrected intraoperative ocular cyclotorsion.

Humans

Effects of automated massage chair therapy on mental health and physical health: A comprehensive study.

BACKGROUND AND OBJECTIVE: Automated massage chair therapy is a non-pharmacological intervention widely believed to enhance wellness, yet evidence regarding its effects remains limited. This 3-part study evaluated the effects of automated massage chair therapy on mental and physical health. METHODS: In Part 1, 20 moderately stressed students were randomized to receive a 20-minute automated massage chair therapy session followed by a 20-minute control session, or vice versa, with a 48-hour washout period. Blood pressure (BP), heart rate (HR), electroencephalogram (EEG), State-Trait Anxiety Inventory (STAI), and Visual Analog Scale (VAS) were measured. In Part 2, 20 hypertensive hospital staff received three 20-minute automated massage chair therapy sessions on alternate days. BP, HR, and skin blood flow (SBF) were measured. In Part 3, 20 hospital staff with chronic low back pain received three 20-minute automated massage chair therapy sessions on alternate days. Electromyogram (EMG) and VAS were measured. RESULTS: Automated massage chair therapy significantly reduced diastolic blood pressure (DBP), HR, stress, and anxiety among moderately stressed students. In hospital staff with hypertension, SBF did not change significantly, whereas BP and HR decreased significantly after automated massage chair therapy. In hospital staff with chronic low back pain, low back function improved, and pain was significantly reduced after automated massage chair therapy. CONCLUSION: These findings indicate that automated massage chair therapy may help reduce stress, lower blood pressure, and alleviate low back pain.

Humans

Repeated low-level red-light therapy for improving asthenopic symptoms and accommodation in presbyopia.

BACKGROUND: To assess the short-term effectiveness of repeated low-level red light (RLRL) therapy in relieving asthenopia and enhancing accommodation in presbyopia. METHODS: This randomized, parallel-group, double-masked clinical trial enrolled adults with presbyopia and self-reported asthenopia. Participants were allocated using computer-generated randomization and randomly assigned at a 1:1 ratio to RLRL or sham groups. Blinding included participants, examiners, assessors, and statisticians. The primary outcome was the change from baseline in the Computer Vision Syndrome Questionnaire (CVS-Q) score at day 31. Secondary outcomes were the change in accommodative amplitude (AA), Near Activity Visual Questionnaire (NAVQ) score, habitual near visual acuity, near-addition power, accommodative facility, positive and negative relative accommodation, binocular cross-cylinder response, and accommodative convergence-to-accommodation ratio. Continuous outcomes were analyzed using linear mixed-effects models. RESULTS: Sixty-four of 66 randomized participants (aged 41-62&#x2009;years) completed the 1-month trial. At day 31, RLRL showed greater improvement than sham in CVS-Q score (adjusted mean difference, -1.75 points; 95% CI, -3.10 to -0.39), binocular AA (1.09 D; 95% CI, 0.37 to 1.82), and NAVQ score (-8.07 points; 95% CI, -14.17 to -1.97). The effect on AA was most pronounced in a subgroup of eyes with baseline amplitude >2.0&#x2009;D (adjusted mean difference 1.33&#x2009;D; 95% CI 0.32-2.34). Other measures did not differ between groups at each visit. No treatment-related adverse events were reported. Adherence was similar between groups (mean compliance: 98.2% vs 97.5%). CONCLUSIONS: Short-term treatment with RLRL significantly reduced asthenopic symptoms and improved accommodative amplitude in individuals with presbyopia.Trial registration: NCT06745661 (registered December 8, 2024).

Humans

The effect of dietetic counseling combined with digital tools intervention on hemodynamic markers in Greek adults: The GATEKEEPER Study.

BACKGROUND AND AIM: Hypertension is a leading cardiovascular risk factor with substantial global impact on morbidity, mortality, and healthcare costs. While lifestyle interventions remain central to management, mHealth technologies offer promising adjunctive support, though their clinical effectiveness remains uncertain. This study evaluated whether combining dietetic counseling with digital tools improves hemodynamic markers in adults aged &#x2265;55 years with increased cardiometabolic risk. METHODS AND RESULTS: This 3-month RCT (NCT05031299) included 954 adults with at least one metabolic syndrome risk factor, allocated 1:1:1 to Standard Care (dietetic counseling), Platform (counseling plus web-based platform), or Platform&#xa0;+&#xa0;Devices (counseling plus platform plus wearables). Outcomes included anthropometrics, lifestyle characteristics, blood pressure, pulse pressure, and estimated pulse wave velocity, analyzed using linear mixed-effects models adjusted for age and sex. All groups improved over 3 months. Waist circumference decreased by -6.29, -4.92, and -4.69&#xa0;cm across Standard Care, Platform, and Platform&#xa0;+&#xa0;Devices groups respectively, and systolic blood pressure declined by -4.84 to -7.15&#xa0;mmHg across groups. The Platform&#xa0;+&#xa0;Devices group showed greater increases in physical activity (94.62 MET-min/week; 95% CI 66.49 to 122.76) and greater reductions in pulse pressure (-3.90&#xa0;mmHg; -6.58 to -1.22) versus Standard Care. Weight loss was associated with lower odds of hypertension (OR 0.4; 95% CI 0.2-0.7), greater likelihood of hypertension reversal (OR 3.6; 1.2-10.3), and higher probability of achieving normal pulse pressure (OR 1.8; 1.1-3.1). CONCLUSIONS: Dietary lifestyle intervention improved cardiometabolic outcomes, with limited added benefit from digital tools. Weight loss was the primary driver of hemodynamic improvement.

Aged

Treatment of OSA using mandibular advancement versus CPAP in improving cardiovascular health.

BACKGROUND: Obstructive sleep apnea is a significant risk factor for hypertension. We assessed the relative effectiveness of mandibular advancement device (MAD) versus continuous positive airway pressure (CPAP) in reducing 24 h ambulatory blood pressure (BP) and other health-related outcomes over 12 months. METHODS: In a randomized, non-inferiority trial, 321 participants with hypertension and increased cardiovascular risk were recruited for polysomnography. Of these, 220 with moderate-to-severe OSA (apnea-hypopnea index (AHI) &#x2265;15 events/hour) were randomized to MAD or CPAP (1:1). We report the final outcomes at the 12-month follow-up. RESULTS: A total of 180 participants (MAD: 89; CPAP: 91) completed the 12-month follow-up. Median usage for MAD and CPAP was 5.5 and 4.9 h per night, respectively. Compared to baseline, the 24 h mean arterial BP at 12 months decreased by 2.3 mmHg (P = 0.200) in the MAD group and by 1.0 mmHg (P = 0.999) in the CPAP group. The difference between-groups was -0.6 mmHg (95% confidence interval: -2.53 to 1.39, non-inferiority P < 0.019). The MAD group demonstrated a larger reduction in asleep BP compared to the CPAP group. The prevalence of excessive daytime sleepiness in the MAD group decreased from 30.3% at baseline to 10.1% at 12-month follow-up (P = 0.001), and from 38.5% to 7.7% in the CPAP group (P < 0.001). The between-group difference was 10.6% (P = 0.097). No significant within-group or between-group differences were observed in the prevalence of arrhythmias and plasma levels of cardiac biomarkers. CONCLUSION: At 12-month, MAD is non-inferior to CPAP for reducing 24 h mean arterial BP in participants with hypertension and increased cardiovascular risk. TRIAL REGISTRATION: NCT04119999.

Humans

Intraocular Pressure Changes Following Intraluminal Stent Removal From the Paul Glaucoma Implant: A Systematic Review and Meta-Analysis.

PURPOSE: This study aims to systematically review and perform a single-arm meta-analysis to comprehensively evaluate the effect of removal of intraluminal stent from the Paul glaucoma implant (PGI) on intraocular pressure (IOP) changes and to summarize its long-term efficacy and safety. CLINICAL RELEVANCE: Glaucoma remains one of the leading global causes of irreversible vision loss, necessitating effective surgical management for refractory cases. Glaucoma drainage devices are critical for these complex forms, and intraluminal stent removal from the PGI serves as a key strategy to titrate aqueous outflow and optimize long-term IOP control. METHODS: A systematic review was conducted by searching EMBASE, Medline, and CENTRAL. The meta-analysis ultimately included 5 observational studies. The Risk of Bias in Nonrandomized Studies of Interventions (ROBINS-I) tool was used to assess the quality of the included studies. Continuous outcomes (eg, postremoval stent IOP reduction) were analyzed using the mean difference (MD) with 95% confidence intervals (CI); dichotomous outcomes (eg, hypotony incidence) were evaluated using pooled proportion with 95% CI. All meta-analyses employed a random-effects model. RESULTS: Our meta-analysis included 5 studies, involving a total of 283 eyes. The meta-analysis revealed that removal of the stent leads to a significant and immediate IOP reduction. The IOP reduction (immediate postremoval stent IOP minus preremoval stent IOP) was significant, with a pooled MD of -9.09 mm Hg IOP (MD = 9.09; 95% CI = [-11.77, -6.41]). In the preremoval stent high-IOP (>21 mm Hg) subgroup, the IOP reduction is -11.82 (95% CI = [-10.14, -13.51]). This reduction was significantly greater than the preremoval stent low-IOP (<21 mm Hg) subgroup, whose reduction is -6.66 mm Hg (95% CI = [-5.55, -7.77]). Regarding safety, the pooled proportion of clinically hypotony was low and highly consistent (I&#xb2; = 0.00%) at only 0.03 (95% CI = [0.00, 0.15]). CONCLUSIONS: Intraluminal stent removal from the PGI is an effective and safe IOP-lowering intervention. Its IOP reduction effect is significantly more pronounced in patients with preremoval stent high IOP, providing crucial clinical guidance for managing persistently high IOP after PGI implantation.

Humans

Association between pulse pressure and markers of cognitive function: a systematic review and meta-analysis.

Our aim was to systematically review and meta-analyse evidence on the association between pulse pressure (PP) and cognitive function using PubMed, PsycInfo, Embase and Scopus (inception-July 2025) publication databases. Studies were included if they reported an association between PP and cognitive function and summarized narratively and by performing fixed-effects meta-analysis. The search identified 4171 publications with 43 studies meeting inclusion criteria. Domains assessed included global cognition, memory, language, attention, executive function, processing speed and visuospatial ability. Meta-analysis suggests a positive association between PP and global cognition, and a negative association with memory in both cross-sectional and longitudinal studies with inconsistent findings from narratively summarized studies. Processing speed, executive function and language negatively associated with PP in cross-sectional studies with limited evidence provided by longitudinal studies or narratively summarized studies. There was limited evidence of an association with attention and visuospatial ability.

Humans

Association Between 24-Hour Blood Pressure and Rates of Retinal Nerve Fiber Layer Progression in Glaucoma: The Vascular Imaging in Glaucoma Study.

PURPOSE: Low systemic blood pressure (BP) has been implicated as a risk factor for glaucoma progression. The purpose of this study was to investigate the association between 24-hour BP and rates of retinal nerve fiber layer (RNFL) loss in eyes with primary open-angle glaucoma. DESIGN: Prospective cohort study. PARTICIPANTS: Seventy-nine eyes from 42 subjects with glaucoma (mean age, 68.5 &#xb1; 7.6 years) enrolled in the Vascular Imaging in Glaucoma Study at the Bascom Palmer Eye Institute. METHODS: Participants underwent 24-hour ambulatory BP monitoring at baseline. Follow-up evaluations were conducted at 4-month intervals and included ophthalmic examination, BP measurement, and peripapillary RNFL thickness measurement with spectral-domain optical coherence tomography. The association between BP and RNFL loss over time was assessed using linear mixed-effects models adjusted for age, sex, race, baseline RNFL thickness, central corneal thickness, and intraocular pressure. MAIN OUTCOME MEASURES: The effect of baseline 24-hour mean arterial pressure (MAP), systolic BP (SBP), and diastolic BP (DBP) on the rate of average RNFL loss over time. RESULTS: Eyes underwent an average of 13 &#xb1; 3 optical coherence tomography exams over 43 &#xb1; 10 months of follow-up. The mean rate of RNFL loss was -0.34 &#xb1; 0.64 &#xb5;m/y (median: -0.32; interquartile range: -0.66 to -0.04 &#xb5;m/y). After adjusting for confounding factors, every 10 mm Hg lower in 24-hour minimum MAP, SBP, and DBP was associated with -0.542 &#xb5;m/y (P < .001), -0.360 &#xb5;m/y (P = .003), and -0.458 &#xb5;m/y (P = .008) faster RNFL loss, respectively. Eyes in the lowest quartile of average 24-hour MAP (81-90 mm Hg) and minimum 24-hour DBP (35-47 mm Hg) experienced significantly faster progression compared to those in the highest quartile, with differences of -0.68 &#xb5;m/y (P = .017) and -0.63 &#xb5;m/y (P = .030), respectively. CONCLUSIONS: Lower systemic BP, especially minimum MAP, SBP, and DBP measured by 24-hour ambulatory BP monitoring, is associated with faster rates of RNFL loss in primary open-angle glaucoma eyes. 24-hour BP monitoring may help predict glaucoma patients at greater risk of progression.

Humans

Efficacy, tolerability, and threshold effect of atropine eye drops for myopia control: A systematic review and dose-response meta-analysis.

Atropine is an emerging therapy for myopia, yet the optimal concentration for prescription remains uncertain. We searched PubMed, Embase, Web of Science, Cochrane Library, World Health Organization International Clinical Trials, and ClinicalTrials.gov registry platforms. We included the randomized clinical trials (RCTs) that compared any dose of atropine against a placebo in myopic children. Among 3566 studies assessed, we identified 33 eligible RCTs involving 6301 children aged 4-18 years, with 10 different concentrations and a mean follow-up time of 19.5&#x202f;&#xb1;&#x202f;12.3 months. A nonlinear relationship was observed between atropine dosage and treatment efficacy (P&#x202f;<&#x202f;0.001). Compared to placebo groups, the mean differences in reducing annual spherical equivalent refraction progression for atropine concentrations of 0.01%, 0.02%, 0.03%, 0.04%, and 0.05% were 0.21 diopters (D) (95% CI, 0.13-0.28), 0.35 D (95% CI, 0.23-0.46), 0.42 D (95% CI, 0.28-0.56), 0.45 D (95% CI, 0.30-0.60), and 0.46 D (95% CI, 0.32-0.61) respectively For higher concentrations, the estimates were 0.49 D (95% CI, 0.34-0.63) for 0.1% and 0.99 D (95% CI, 0.66-1.31) for 1%, although these were based on fewer and smaller trials. Higher doses of atropine were associated with decreased amplitude of accommodation (P&#x202f;=&#x202f;0.02), increased pupil diameters (P&#x202f;=&#x202f;0.01) and a higher frequency of photophobia (P&#x202f;=&#x202f;0.02). Our findings suggest that the increase in treatment efficacy with higher concentrations may plateau beyond a certain range, and that the current practice of increasing atropine concentrations for children who show inadequate responses to lower doses should be confined to a specific concentration range. This analysis is limited by the number, design heterogeneity, and sample sizes of available trials for higher concentrations, and by the frequent lack of pre-intervention refractive history in included studies. Therefore, estimates-particularly for doses exceeding 0.1%-should be interpreted with caution.

Humans

Venous Sinus Stenting for Pulsatile Tinnitus: A Systematic Review and Meta-Analysis.

BACKGROUND: Pulsatile tinnitus (PT) is frequently caused by venous sinus stenosis and may be associated with idiopathic intracranial hypertension (IIH). Venous sinus stenting (VSS) directly addresses venous outflow obstruction and has emerged as a therapeutic option; however, outcome data remain heterogeneous. We performed an updated systematic review and meta-analysis to evaluate the efficacy and durability of VSS for PT and to compare outcomes between IIH-associated and isolated PT. METHODS: MEDLINE, Scopus, and Web of Science were searched from inception through December 2025 following PRISMA guidelines. Clinical studies reporting PT outcomes after VSS were included. Random-effects meta-analyses of proportions were conducted to estimate pooled rates of overall improvement, complete resolution, and recurrence. Prespecified subgroup analyses compared IIH versus isolated PT. RESULTS: Thirty-two studies comprising 850 patients were included (641 with IIH; 209 with isolated PT). Venous sinus stenosis accounted for 90.3% of treated etiologies. The pooled rate of overall PT improvement was 89.8% (95% CI, 85.5-92.9). Complete resolution occurred in 87.1% (95% CI, 82.5-90.6). Recurrence at last follow-up was 10.9% (95% CI, 8.3-14.2). Improvement and complete resolution rates did not differ significantly between IIH and isolated PT. Recurrence was higher in IIH (12.0%) than in isolated PT (5.7%), without reaching statistical significance. CONCLUSIONS: VSS is associated with high rates of PT improvement and complete resolution with low recurrence. Recurrence trends appear higher in IIH, suggesting underlying pathophysiology may influence durability.

Humans

Prevalence and cardiometabolic impact of mild autonomous cortisol secretion in primary aldosteronism: a systematic review and meta-analysis.

Many primary aldosteronism (PA) patients harbor concomitant mild autonomous cortisol secretion (MACS), termed "Connshing syndrome." The prevalence and cardiometabolic impact of this co-secretion have not been quantitatively synthesized. To determine the pooled prevalence of MACS in PA and evaluate its association with cardiovascular (CV) events, type 2 diabetes mellitus (T2DM), and obesity. PubMed, Embase, Cochrane, Web of Science, and Scopus through January 2026. Following PRISMA 2020 and MOOSE guidelines (PROSPERO: CRD420261334965), studies reporting MACS prevalence [post-1&#x200a;mg dexamethasone suppression test (DST) cortisol &#x2265;1.8&#x200a;&#x3bc;g/dl] in PA were included. Prevalence was pooled using random-effects models. Odds ratios (ORs) were calculated for cardiometabolic outcomes. Certainty was evaluated using GRADE. Fourteen studies (2356 patients) were included. Pooled MACS prevalence was 26.2% [95% confidence interval (CI): 24.1-28.4; I2 = 24.2%; prediction interval: 21.6-31.4%], consistent across European (27.0%) and East Asian (25.2%) cohorts ( P = 0.62). MACS + PA patients had higher odds of CV events (OR 1.60; 95% CI: 1.07-2.38; P = 0.021) and T2DM (OR 1.37; 95% CI: 1.00-1.86; P = 0.048), but not obesity (OR 1.10; P = 0.411). Sensitivity analyses confirmed robustness. GRADE certainty was moderate for prevalence and low for CV events. Approximately one in four PA patients has MACS, associated with a 60% higher CV event risk. These findings support routine DST screening in PA and have implications for perioperative management and cardiometabolic risk stratification.

Humans