Search PubMedSearch

SEARCH · Search PubMed

Results for “Enrofloxacin detection”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

220 records · Page 2Linked to original sources

Liquid biopsy-based detection of circulating and exfoliated cholangiocarcinoma tumor cells from blood and bile using heparan sulfate octasaccharides on integrated microfluidic systems.

Early diagnosis of cholangiocarcinoma (CCA) remains challenging because existing diagnostic approaches often lack sufficient sensitivity for reliable detection of early-stage disease. Circulating tumor cells (CTCs) in blood and exfoliated tumor cells (ETCs) in bile represent valuable targets for liquid biopsy-based detection; however, their low abundance and the complexity of clinical sample analysis pose substantial technical challenges for reliable enrichment and identification. Herein, we present a reproducible workflow for isolating and identifying CCA tumor cells from blood for CTCs and bile for ETCs using synthetic cell-surface heparan sulfate (HS) octasaccharide-functionalized magnetic beads (MBs) on integrated microfluidic systems. The method combined sample pre-processing, magnetic bead-based enrichment, controlled low-shear mixing and immunofluorescence-based identification into a unified workflow compatible with distinct clinical sample types. Key operational parameters, including MB concentration, mixing frequency, and pressure settings, were detailed to facilitate consistent performance. Using this workflow, tumor cell capture rates of approximately 70% in bile (for ETCs) and blood (for CTCs) were achieved, with a total processing time of 60-90 min per sample under clinically relevant low-abundance conditions. The platform enables reliable detection of as few as 1 tumor cell per mL of blood or bile. This method provides a practical and adaptable strategy for glycosaminoglycan-mediated liquid biopsy applications and may be extended to other tumor-cell enrichment workflows involving heterogeneous cell-surface interactions.

Humans

Linked-color imaging with computer-aided detection and the proximal adenoma miss rate: a randomized tandem trial.

BACKGROUND AND AIMS: Linked-color imaging (LCI) aids the detection and characterization of lesions. Computer-aided detection (CADe) systems have been introduced to improve lesion detection during colonoscopy. Although several studies have been reported regarding LCI, few have investigated the combination of LCI and CADe. This study aimed to evaluate the efficacy of LCI with CADe colonoscopy compared to conventional white-light colonoscopy. METHODS: A single-center, randomized tandem trial was conducted. Participants referred for first-time colonoscopy after fecal immunochemical test (FIT)-positive, asymptomatic screening, or surveillance colonoscopy were randomized (1:1) to undergo CADe-assisted colonoscopy of LCI or white-light imaging (WLI) in the right side of the colon. The primary outcome was adenoma miss rate (AMR) in the right side of the colon. Secondary outcomes included polyp miss rate (PMR), diminutive adenoma miss rate (dAMR), sessile serrated lesion miss rate (SSLMR), advanced adenoma miss rate, advanced neoplasia miss rate, flat-type lesion miss rate (FMR), and the differences in miss rates based on expertise. RESULTS: Among 232 randomized participants, 209 were analyzed (LCI/CADe: 102; WLI: 107). AMR (WLI: 39% vs LCI/CADe: 20%; P = .001), PMR (42% vs 18%; P < .001), and dAMR (42% vs 21%; P = .003) were significantly lower in the LCI/CADe arm, particularly among experts. SSLMR (46% vs 0%), advanced AMR (30% vs 0%), advanced neoplasia miss rate (25% vs 0%), and FMR (27% vs 5.6%) were lower in LCI/CADe, although without statistical significance. CONCLUSIONS: Compared to conventional colonoscopy, LCI with CADe colonoscopy resulted in a statistically significant decrease, especially in AMR. (UMIN 000050685).

Humans

Artificial intelligence for dental caries detection: An umbrella review.

Artificial intelligence (AI) has been proposed as a tool to improve dental caries detection across imaging modalities; however, its clinical value remains uncertain. This umbrella review aimed to synthesize and critically appraise systematic reviews evaluating AI for caries detection and diagnosis. An umbrella review was conducted following PRIOR guidance (PROSPERO CRD420261340728). Searches were performed in MEDLINE, Embase, Scopus, Web of Science, and Google Scholar up to 15 March 2026. Methodological quality was assessed using AMSTAR 2, and overlap of primary studies was quantified using the corrected covered area (CCA). Seventeen systematic reviews were included, of which five reported diagnostic test accuracy meta-analyses using bivariate or HSROC models. Across these meta-analyses, pooled sensitivity ranged from 0.76 to 0.94 and specificity from 0.85 to 0.91. Most systems were based on deep learning models applied to bitewing radiographs and intraoral photographs. However, substantial heterogeneity was observed in imaging modalities, lesion thresholds, analytical tasks, and evaluation metrics. In addition, a high degree of overlap across reviews and recurrent methodological limitations, including reliance on retrospective datasets, limited external validation, and inconsistent reporting, substantially weaken the reliability of the evidence. Although AI models demonstrate high diagnostic performance under experimental conditions, current evidence does not support their use as stand-alone diagnostic tools. Their clinical applicability remains limited, and implementation should be restricted to decision-support contexts until robust prospective validation demonstrates meaningful impact on clinical decision-making and patient outcomes.

Dental Caries

Metal-organic frameworks nanozyme-integrated portable microneedle patch for visual bacterial monitoring in meat.

Foodborne microbial contamination is a major global health concern, with conventional methods often being time-consuming and complex. Herein, we developed a novel portable biosensor by integrating microneedle patch technology and a metal-organic framework (Fe/Cu-NBDC MOF) nanozyme, enabling rapid, on-site, visual detection of bacteria in meat. The sensing system works by encapsulating aptamer-functionalized MOF nanozymes within a hydrogel patch, where their catalytic sites are initially blocked by the aptamer. In the presence of Staphylococcus aureus (S. aureus) as the target, the specific aptamer's binding to bacteria exposes numerous catalytic sites, further activating the chromogenic reaction of the tetramethylbenzidine&#x2011;hydrogen peroxide (TMB-H&#x2082;O&#x2082;) system, enabling visual detection of S. aureus. The biosensor demonstrates a detection limit of 82&#xa0;CFU/mL with excellent specificity to successfully apply to commercial mutton. By integrating sampling, enrichment, and visual detection into a single compact device, this platform offers a practical, efficient solution for rapid on-site screening of foodborne pathogens.

Biosensing Techniques

Artificial intelligence-assisted detection and optical differentiation of colorectal lesions in Lynch syndrome surveillance (CADLY2): a multicentre, open-label, randomised controlled superiority trial.

BACKGROUND: Artificial intelligence (AI)-based computer-aided detection (CADe) systems improve adenoma detection in average-risk colorectal cancer screening. Meanwhile, evidence in Lynch syndrome surveillance is sparse and inconsistent. We assessed the effect of CADe on adenoma detection during Lynch syndrome surveillance. Computer-aided optical diagnosis (CADx) performance for optical differentiation of colorectal lesions was evaluated as a secondary aim. METHODS: CADLY2 was an international, multicentre, open-label, randomised controlled superiority trial at nine specialised hereditary cancer surveillance centres in Belgium, Germany, the Netherlands, and Spain. Adults aged 18 years or older with genetically confirmed Lynch syndrome scheduled for surveillance colonoscopy were randomly assigned (1:1) to high-definition white-light (HD-WL) colonoscopy alone or to HD-WL colonoscopy with computer-aided assistance from CAD EYE (Fujifilm, Tokyo, Japan). CAD EYE was used for CADe during withdrawal and for CADx after lesion detection. Randomisation was done centrally through a secure web-based system using Pocock's minimisation algorithm with a stochastic component and was stratified by centre, sex, previous colorectal cancer, underlying pathogenic variant, and interval since previous colonoscopy. Allocation concealment was ensured through the centralised web-based system. Patients were masked to group allocation until the start of withdrawal in procedures with mild sedation, or until completion of the procedure in procedures with propofol-based sedation. Endoscopists were not masked. The primary outcome was adenoma detection rate, defined as the proportion of patients with at least one histopathologically confirmed adenoma, analysed in the full analysis set (defined as all randomly allocated patients with available data for the primary outcome). The diagnostic performance of the CADx system was evaluated as a secondary outcome. The safety analysis set comprised all randomly allocated patients who underwent a study colonoscopy. This study is registered with the German Clinical Trials Register, DRKS00030695, and is completed. FINDINGS: Between May 9, 2023, and Oct 30, 2025, 757 patients were randomly allocated to HD-WL colonoscopy (377 patients) or to AI-assisted colonoscopy (380 patients); 733 patients were included in the full analysis set (369 HD-WL and 364 AI-assisted). The median age was 49 years (IQR 38-59) in the HD-WL group and 50 years (38-59) in the AI-assisted group; 213 (58%) were female and 156 (42%) male in the HD-WL group, and 207 (57%) were female and 157 (43%) male in the AI-assisted group. The adenoma detection rate was 30&#xb7;9% (114 of 369 patients) with HD-WL versus 33&#xb7;8% (123 of 364 patients) with CADe assistance (odds ratio 1&#xb7;14 [95% CI 0&#xb7;83-1&#xb7;57], p=0&#xb7;41). For CADx differentiation of neoplastic versus non-neoplastic lesions in the paired lesion-level analysis, with histopathology as the reference standard and sessile serrated lesions and traditional serrated adenomas classified as non-neoplastic, CADx sensitivity was 85&#xb7;9% (95% CI 82&#xb7;0-89&#xb7;1) and specificity was 91&#xb7;4% (89&#xb7;4-93&#xb7;0). Three adverse events occurred in the AI-assisted group: two mild post-polypectomy bleedings and one serious pulmonary embolism or deep venous thrombosis unrelated to the procedure. No adverse events occurred in the HD-WL group. INTERPRETATION: CADe-assisted colonoscopy did not show the absolute improvement in adenoma detection rate that was assumed in the prespecified sample-size calculation. CADx did not clearly improve lesion differentiation beyond expert optical diagnosis in expert Lynch syndrome surveillance settings. FUNDING: Third-party research funding of the National Center for Hereditary Tumor Syndromes, University Hospital Bonn.

Humans

Enhancing Hemoglobin Bart's hydrops fetalis syndrome prevention: a single-tube multiplex real-time PCR assay for the comprehensive detection of four significant &#x3b1;0-thalassemia deletions (--SEA, --THAI, --CR, and --SA) found in Thailand.

BACKGROUND: Hemoglobin (Hb) Bart's hydrops fetalis is a major public health concern in Southeast Asia, particularly in Thailand. Current screening strategies target the two most common &#x3b1;0 -thalassemia deletions (--SEA and --THAI). METHOD: In this study, we developed a single-tube multiplex real-time PCR assay for the simultaneous detection of four clinically relevant &#x3b1;0-thalassemia deletions (--SEA, --THAI, --CR, and --SA). The assay was validated using 538 clinical samples with diverse thalassemia genotypes and compared against conventional gap-PCR as the reference method. Analytical performance, including sensitivity, specificity, and limit of detection (LOD), was evaluated. In addition, clinical utility was assessed in 22 prenatal diagnosis cases at risk of Hb Bart's hydrops fetalis. RESULTS: The study cohort demonstrated substantial genetic heterogeneity, comprising 43 distinct genotypes. The developed assay achieved 100% sensitivity and specificity for all targeted deletions, with complete concordance with gap-PCR results. No cross-reactivity was observed with &#x3b1;+-thalassemia. The assay demonstrated a high analytical sensitivity with a LOD of 9.76&#x2009;&#xd7;&#x2009;10-3&#x2009;ng per reaction. Whereas in prenatal diagnosis, all 22 fetal genotypes were accurately identified, including five cases of homozygous --SEA and one rare compound heterozygous --SEA/--CR fetus. CONCLUSIONS: This study presents a rapid, accurate, and cost-effective multiplex real-time PCR assay capable of detecting both common and rare &#x3b1;0-thalassemia deletions in a single reaction. The assay demonstrates strong potential for implementation in routine clinical laboratories and large-scale population screening, contributing to improved prevention and control of severe thalassemia syndromes in high-prevalence regions.

Humans

Single-slice Functional Lung MRI During Metronome-Paced Tachypnea Detects Changes in Regional Ventilation Dynamics After a Single Dose of Dual Bronchodilator Treatment in COPD.

Dual long-acting bronchodilators are a standard treatment in chronic obstructive pulmonary disease (COPD), aimed at alleviating dyspnea, improving exercise tolerance, and preventing exacerbations. Metronome-paced tachypnea (MPT) offers a feasible alternative to exercise testing for the evaluation of dynamic hyperinflation (DH) in COPD. Because MPT can be performed during MRI, its combination with single-slice phase-resolved functional lung (PREFUL) MRI provides a promising approach to investigate changes in regional ventilation dynamics induced by DH. This approach was evaluated in a randomized, investigator-blinded, placebo-controlled, single-dose (SD) crossover trial with a two-week extension of once daily dual bronchodilator medication, in which patients with stable COPD underwent PREFUL MRI during resting tidal breathing (RTB) and during MPT. During RTB, no significant improvements in MRI-derived parameters were observed after SD treatment compared with placebo. During MPT, however, regional ventilation, flow-volume loop correlation, its defect percentage, and end-expiratory lung area improved significantly after SD treatment compared to the placebo scan (all p&#x2009;<&#x2009;0.02). After multi-dose treatment, five out of six measured parameters improved during MPT, when compared to the baseline scan without bronchodilator treatment (all p&#x2009;<&#x2009;0.03). In contrast to RTB, PREFUL MRI during MPT was able to detect changes in COPD patients already after SD treatment. The combination of MPT and PREFUL MRI represents a promising method to evaluate the effects of dual bronchodilators on regional ventilation dynamics and hyperinflation.

Humans

Effectiveness of STK Spray&#xae; for semen stain localization on solid surfaces: A specificity and sensitivity study.

Semen identification is a crucial step in sexual assault cases. The aim of this study was to assess STK Spray&#xae;, a presumptive test for semen, under controlled conditions including, simulated crime scene stains detection. Easy to use, it can be sprayed directly onto different surfaces and visualized under UV light. Several tests were performed on five different substrates (ceramic tile, drywall, metal, wood, and faux leather). The spray was able to enhance semen fluorescence, especially in diluted samples, with characteristic "globular" spots. Although it showed good specificity, false positives could be obtained with 10% bleach. The fluorescence signals were quantified using ImageJ&#x2122; and showed a statistically significant substrate-dependent variability. Mixture analysis indicated that saliva did not interfere with detection of semen, while urine partially suppressed the signal and blood markedly affected its interpretation. Simulation tests with UV lamp comparisons confirmed the importance of choosing the right detection method and the utility of this presumptive test in combination with additional immunochromatographic tests. A preliminary signal retention test showed stable fluorescence for up to two years when stains were stored appropriately. Finally, complete DNA profiles (100% of alleles) were obtained from all samples (n&#xa0;=&#xa0;24) after exposure to the reagent and UV light. Because of its ability to enhance semen signal, especially on specific surfaces, and its rapidity of use and detection, STK Spray&#xae; may represent a useful aid in the preliminary screening phase.

Humans

Artificial intelligence-supported double reading in European population breast cancer screening: A systematic review and meta-analysis of prospective programs.

BACKGROUND: Most European population mammography screening programs rely on double reading with arbitration, a model that delivers mortality benefit but is increasingly challenged by radiologist workload, variable specificity, and interval cancers. Artificial intelligence (AI) is being evaluated to support or optimize these established European screening pathways. PURPOSE: To synthesize prospective or program-embedded evaluations of AI conducted within European-style population screening programs and to estimate exploratory program-level absolute risk differences (RDs) per 1000 examinations for cancer detection rate (CDR) and recall. MATERIALS AND METHODS: We performed a prespecified, focused evidence synthesis of three large studies embedded within routine population screening programs operating under European-relevant workflows: MASAI (randomized AI-supported risk triage within a national program), ScreenTrustCAD (prospective paired-reader evaluation with AI as an independent reader in a double-reading framework), and PRAIM (nationwide decision-referral implementation). Outcomes were harmonized as AI-control RDs per 1000 examinations. Random-effects pooling used Hartung-Knapp-Sidik-Jonkman models. For the paired-reader design, sensitivity analyses applied a Kish effective sample-size approach across plausible within-examination correlations (&#x3c1;&#xa0;=&#xa0;0.3-0.8). Positive predictive value (PPV) and workflow/time outcomes were summarized descriptively. RESULTS: Across 597,419 examinations, the pooled CDR RD was +0.9 per 1000 (95% CI -0.0 to +1.8; I2&#xa0;&#x2248;&#xa0;12%), consistent with a modest directional increase with borderline statistical uncertainty. The pooled recall RD was -0.6 per 1000 (95% CI -3.1 to +2.1; I2&#xa0;&#x2248;&#xa0;41-43%), indicating no consistent recall increase across screening programs. Where reported, PPV was higher with AI-supported screening. Efficiency signals included 44.3% fewer total readings in MASAI and shorter reading times for AI-normal examinations in PRAIM; in PRAIM, a program-level safety-net mechanism recovered 204 cancers that would otherwise have been missed. CONCLUSION: In European population screening programs characterized by double reading and arbitration, prospective program-embedded evidence suggests that AI integration may yield a small absolute increase in cancer detection (&#x2248;1/1000) without a consistent increase in recall, alongside improved PPV and efficiency signals. These findings suggestAI primarily as a complementary reader within European screening workflows, with implementation requiring explicit quality assurance and monitoring of interval cancers and stage distribution.

Humans

Vortex-assisted liquid-liquid microextraction based on natural deep eutectic solvents for the determination of pyrethroid pesticides in urine.

A novel, facile, and environmentally friendly analytical method was developed based on vortex-assisted liquid-liquid microextraction and high-performance liquid chromatography with diode-array detection for detecting pyrethroid pesticides (PPs) in urine. Natural deep eutectic solvents (NADESs) were prepared using plant essential oil-derived monoterpenoids (thymol, carvacrol, and menthol) combined with aromatic primary alcohols (benzyl alcohol, phenethyl alcohol, and phenylpropyl alcohol) as hydrogen bond donors and acceptors. These solvents served as environmentally benign extraction media, thereby avoiding the use of conventional volatile, toxic organic solvents. NADESs are naturally derived, easy to prepare, biodegradable, and environmentally friendly solvents. Hydrophobic and &#x3c0;-&#x3c0; interactions between the NADESs and PPs may contribute to enhancing the affinity of PPs toward the NADESs phase. Vortex technology, accelerating mass transfer between the sample and extractant phases, enables fast extraction of PPs. Under optimized conditions, the method achieved a low detection limit (0.002&#xa0;mg&#xa0;L-1), satisfactory precision with relative standard deviations (0.3%-2.4%), and acceptable recovery (80.7%-86.2%). The method demonstrated excellent performance in urine analysis and was feasible as a facile and green strategy for monitoring the content of PPs in biological matrices and assessing exposure risk.

Liquid Phase Microextraction

HPV Testing Versus Cytology for Cervical Cancer Screening&#xa0;Among Women 50&#x2009;Years and Older: Evidence From the HPV FOCAL Randomized Controlled Trial.

Evidence on the comparative effectiveness of HPV testing versus cytology specifically in women aged &#x2265;&#x2009;50&#x2009;years who are approaching screening cessation remains limited. This analysis included 6471 women aged &#x2265;&#x2009;50 at baseline screening in the HPV FOCAL randomized clinical trial. Women were randomly allocated to receive cytology (Control Group, n&#x2009;=&#x2009;3248, 50.19%) or HPV testing (Intervention Group, n&#x2009;=&#x2009;3223, 49.81%) at baseline, with co-testing at 48-month exit. We calculated incidence rates and risk ratios for CIN2+ detection over follow-up and compared missed lesions at exit by screening method. At the 48-month exit, CIN2+ detection was lower among HPV baseline-negative women than among those in the cytology group (1.61/1000 [95% CI, 0.52-3.76] vs. 3.15/1000 [95% CI, 1.51-5.78]; risk ratio, 0.51 [95% CI, 0.11-0.91]), reflecting higher baseline detection with HPV testing and fewer prevalent lesions at exit. Even with cytology re-screening at 2&#x2009;years, 50% of CIN2+ cases were missed compared to 30% with HPV testing. After adjusting for age, education, smoking status, and lifetime sexual partners, the hazard ratio for CIN2+ comparing HPV to cytology was 0.44 (95% CI, 0.22-0.88). Among women aged &#x2265;&#x2009;50&#x2009;years, HPV primary screening was more effective than cytology at detecting CIN2+ lesions and was associated with a continued lower subsequent risk following a negative HPV test, supporting its use in cervical cancer screening programs in this age cohort.

Aged

Antimicrobial resistance in Staphylococcus spp. isolated from sporotrichosis-affected cats in Brazil: Detection of MRSP and MRSA.

Recently, Brazil has experienced a zoonotic emergence of sporotrichosis. The associated cutaneous lesions are often extensive and slow to heal, thereby providing a gateway for opportunistic bacteria belonging to the normal skin microbiota. Among these, Staphylococcus spp. are of particular concern due to their high prevalence and notable levels of antimicrobial resistance. The objective of this study was to identify and characterize Staphylococcus spp. isolated from the cutaneous wounds of domestic cats undergoing treatment for sporotrichosis and exhibiting clinical signs of secondary bacterial infection. A total of 233 samples from 203 cats were analyzed. Staphylococcus spp. was isolated from 156 samples (67%), with S. aureus (42.3%) and S. felis (25.6%) being the most prevalent. Antimicrobial susceptibility testing revealed high levels of resistance to penicillin (51.9%), erythromycin (28.8%), and clindamycin (19.2%). In contrast, most isolates were susceptible to chloramphenicol (98%), ciprofloxacin (96.7%), and nitrofurantoin (93%). Multidrug-resistant strains were identified in 24% (38/156) of the isolates. Overall, 12 isolates (7.7%) were classified as methicillin-resistant staphylococci, including four methicillin-resistant S. pseudintermedius (MRSP) and one methicillin-resistant S. aureus (MRSA). To investigate the genetic profiles and epidemiological relationships of these isolates, all the MRSP and MRSA strains were subjected to whole-genome sequencing. Among the MRSP isolates, four sequence types (STs) were identified, including ST551, the founder of clonal complex (CC)551, which is commonly associated with infection in dogs. The MRSA isolate belonged to ST1176, a member of CC5, which is a globally prevalent lineage and is frequently associated with nosocomial infections in humans. This study demonstrates that Staphylococcus species, including methicillin-resistant isolates, are frequently present in the wounds of sporotrichosis-infected cats exhibiting clinical signs of secondary bacterial infection. The detection of MRSA and MRSP in a cat highlights an additional public health concern associated with feline sporotrichosis and further reinforces the growing concern regarding antimicrobial resistance in companion animals.

Animals

Improved comprehensive profiling of fecal bile acids through chemical derivatization combined with HPLC-MS/MS analysis.

Bile acids (BAs) facilitate the digestion and absorption of fats and influence lipid and glucose homeostasis, making them potential therapeutic targets for obesity and related metabolic disorders. The liver and intestinal microbiota modify BAs structurally, generating diverse chemical forms and isomers. Comprehensive profiling of the BA pool is critical for understanding their key biological functions and as a therapeutic approach for related diseases. High-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) is usually chosen as the preferred method for BA detection due to the complex chemical structures, the wide range of actual concentrations and the complexity of fecal sample matrices. However, free BAs are difficult to ionize, resulting in low detection signals and a lack of characteristic structural fragments to assist in structural identification. In this method, the labeling reagent (2-aminoethyl) trimethylammonium (AETMA) is employed to label the carboxyl group of BAs. Compared with underivatized BAs, the detection sensitivity of unconjugated BAs was enhanced by 25-180 fold, while that of conjugated BAs increased by 6-160 fold. It also generates unique fragment ions and enhances MS response, facilitating the discovery of potential BAs. Methodological parameters were validated using 38 BAs as representatives. Through methodological validation, it was verified that the precision, recovery, matrix effect and stability parameters of the method met acceptable criteria. We also identified 61 confirmed BAs and 55 additional candidate BAs in human pooled fecal samples. It has been successfully applied to fecal BA analysis in obese populations, providing valuable insights into potential therapeutic strategies for obesity.

Tandem Mass Spectrometry

Morphology-engineered NiFe@C nanocages boosting electrochemical quantification of ractopamine in meat samples.

It is essential to acquire efficient electrocatalysts to develop ractopamine (RAC) electrochemical sensors. Herein, we report the synthesis of a series of carbon coated NiFe alloy nanostructures (e.g., NiFe@C nanoparticles, nanocubes and nanocages) using NiFe Prussian blue analogue (PBA) as the precursor. The NiFe@C nanocages exhibited the best electrocatalytic performance for RAC sensing. This is attributed to the embedded NiFe alloy nanoparticles that provide abundant active sites, and the unique nanocage structure facilitates electron transfer pathways while offering a high specific surface area. The resulting sensor achieves a low detection limit (LOD) of 54&#xa0;nM (S/N&#xa0;=&#xa0;3) within a linear range of 0.2-12&#xa0;&#x3bc;M. Moreover, the sensor demonstrates good reproducibility, stability, and excellent long-term stability. Practical applicability was confirmed in meat samples, yielding satisfactory recovery rates ranging from 98% to 108%. A feasible strategy was introduced herein for rational design of metal@carbon electrocatalysts.

Phenethylamines

Cine-derived mitral annular relaxation velocity for detection of preclinical left ventricular diastolic dysfunction.

OBJECTIVES: Imaging diastolic dysfunction in pre-clinical heart failure (HF) is challenging. We evaluated a novel cardiac MRI (CMR) biomarker, CMR e-prime (CMR-MARV), in patients at risk of HF. METHODS: In this substudy of the PARABLE trial (NCT04687111), 236 patients (71.6&#xa0;&#xb1;&#xa0;7.7&#xa0;years, 61.6% male) fulfilling trial-defined ALVDD citeria underwent CMR with measurement of mitral annular relaxation velocity (CMR-MARV) at four mitral annular anchor points. Diastolic strain rates from FT were also assessed. Twenty-five age- and sex-matched controls were included (73.8&#xa0;&#xb1;&#xa0;3.1&#xa0;years, 52% male). Group differences were tested with t-tests, diagnostic accuracy with ROC analysis, and predictors of diastolic dysfunction with adjusted logistic regression. RESULTS: Compared with controls, patients had significantly higher indexed maximal left atrial volume (LAVimax), LV end-diastolic and end-systolic volumes, and LV mass (all p&#xa0;<&#xa0;0.001). Of FT variables, only peak diastolic longitudinal velocity differed between groups (p&#xa0;<&#xa0;0.001). In multivariate models, CMR-MARV correlated with radial, circumferential, and longitudinal diastolic strain rates, radial and longitudinal diastolic velocities (all p&#xa0;<&#xa0;0.001), echocardiographic e' (r&#xa0;=&#xa0;0.20, p&#xa0;=&#xa0;0.007), LV mass (r&#xa0;=&#xa0;-0.18, p&#xa0;=&#xa0;0.008), LAVimax (r&#xa0;=&#xa0;-0.18, p&#xa0;=&#xa0;0.008), and NT-proBNP (r&#xa0;=&#xa0;-0.30, p&#xa0;<&#xa0;0.0001). LAVimax and CMR-MARV were strongly independently associated with ALVDD (AUC 0.89 and 0.76, respectively; p&#xa0;<&#xa0;0.0001). A combined model (LAVimax + CMR-MARV) achieved excellent discrimination (AUC 0.91, 95% CI 0.86-0.97, p&#xa0;<&#xa0;0.0001). Independent predictors included LAVimax, CMR-MARV, and peak diastolic longitudinal velocity (all p&#xa0;<&#xa0;0.001). CONCLUSION: CMR-MARV provides a simple cine-derived measure of longitudinal relaxation that correlates with established structural and biochemical markers of diastolic burden. Within an at-risk population, it offers incremental functional information beyond conventional parameters and may support multiparametric CMR phenotyping of preclinical diastolic dysfunction.

Aged

Phase-resolved functional lung MRI detects single-dose and sustained bronchodilator responses in COPD in a randomized crossover trial.

OBJECTIVES: To evaluate the effects of tiotropium/olodaterol (T/O) on phase-resolved functional lung (PREFUL) MRI parameters in hyperinflated chronic obstructive pulmonary disease (COPD) patients and examine correlations with conventional cardiopulmonary and hyperpolarized 129Xe MRI measures. MATERIALS AND METHODS: Retrospective subanalysis of a prospective, randomized, placebo-controlled, crossover trial with open-label extension. Thirty-two patients with moderate-to-severe COPD (61.5&#x2009;&#xb1;&#x2009;7.7 years; 17 men); 30 completed the MRI extension at 1.5&#x2009;T. PREFUL analysis yielded regional ventilation (RVent), flow-volume loop correlation metric (FVL-CM), normalized perfusion (QN), ventilation defect percentage (VDP), perfusion defect percentage (QDP), V/Q match metrics (VQM), and pulmonary pulse wave velocity (PWV; post-hoc parameter). Linear mixed-effects models tested treatment effects; correlations were evaluated with Spearman's rank and bootstrap 95% confidence intervals (95% CIs). RESULTS: PREFUL parameters improved after T/O single dose (SD) versus placebo, including improvements in FVL-CM by 4.1 percentage points (pp; 95% CI: 1.0 to 7.3 pp) and QN by 0.4 pp (95% CI: 0.2 to 0.6 pp) and reductions in VDP and QDP, with parallel gains in VQM(Non-Defect) (p&#x2009;<&#x2009;0.05). PWV decreased after multiple doses (-0.87&#x2009;m/s, 95% CI: -1.26 to -0.48&#x2009;m/s). PREFUL MRI baseline values showed significant correlations with pulmonary function tests, cardiac, dynamic contrast-enhanced and 129Xe MRI. SD treatment-induced absolute changes in VDP(FVL-CM) correlated with reductions in residual volume (&#x3c1;&#x2009;=&#x2009;0.41, 95% CI: 0.02 to 0.64). Further correlations were observed between PREFUL MRI and &#xb9;&#xb2;&#x2079;Xe-derived VDP, apparent diffusion coefficient, and compartment ratios. CONCLUSION: PREFUL MRI sensitively captured immediate SD T/O-induced improvements in V/Q parameters and dose-dependent PWV responses after sustained bronchodilation. KEY POINTS: Question Can phase-resolved functional lung (PREFUL) MRI sensitively capture immediate single-dose and sustain multi-dose effects of tiotropium/olodaterol on ventilation-perfusion and vascular function in COPD patients? Findings Tiotropium/olodaterol improved PREFUL MRI-derived ventilation, perfusion, and V/Q matching parameters after a single dose, with sustained pulmonary vascular improvements after repeated dosing. Clinical relevance PREFUL MRI detected immediate and sustained functional improvements after tiotropium/olodaterol and showed significant correlations with cardiopulmonary tests and hyperpolarized &#xb9;&#xb2;&#x2079;Xe MRI, supporting its role as a sensitive, radiation-free tool for monitoring COPD treatment response.

Humans

A smartphone-integrated Pt@Cu-HCF nanozyme-based paper sensor for on-site determination of total antioxidant capacity in marine oils.

Total antioxidant capacity (TAC) serves as a key indicator for evaluating the nutritional quality of foods. In this study, we designed a platinum-embedded copper hexacyanoferrate (denoted as Pt@Cu-HCF) nanozyme that exhibits high oxidase-like activity, efficiently catalyzing the oxidation of chromogenic substrates to generate robust colorimetric signals. Antioxidants quench hydroxyl radicals (&#x2219;OH) produced during the catalytic process, leading to a concentration-dependent suppression of the color signal. Leveraging this mechanism, a smartphone-integrated, colorimetric paper sensor for on-site TAC quantification was developed, using vitamin E as the calibration standard. The sensor was applied to determine TAC in fish oil, algal oil, and krill oil, demonstrating a linear response range of 9.78-312.5&#xa0;&#x3bc;M and a limit of detection (LOD) of 6.41&#xa0;&#x3bc;M. Validation using real-world marine oil samples showed excellent agreement with a commercial assay kit, confirming the reliability and practical applicability of this portable sensor for TAC measurement in complex biological matrices.

Antioxidants

Development and validation of a liquid chromatography-tandem mass spectrometry method for the quantification of twenty-five steroids in equine serum.

Steroids are potential biomarkers for monitoring equine pregnancy. However, immunoassays currently used for their quantification suffer from cross-reactivity and limited specificity, thus requiring more accurate methods. This study reports the development and validation of a robust liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous quantification of 25 steroids covering the main biosynthetic pathways of progestogens, corticosteroids, androgens, and estrogens. Steroids were extracted by protein precipitation followed by evaporation, derivatization, and reconstitution before LC-MS/MS analysis. A surrogate matrix was used for calibration and validation to avoid endogenous interference. Validation was performed according to and partly adapted from Clinical and Laboratory Standards Institute guidelines (CLSI), including linearity, trueness, precision, limits of detection and quantification, measurement uncertainty, recovery, matrix effects, carryover, selectivity, and stability. Calibration curves were fitted using the best-performing weighted linear or quadratic regression model, yielding excellent linearity (R2&#xa0;>&#xa0;0.990), trueness between -9.0% and 2.3%, and intra- and inter-day precision <6.3%. Lower limits of quantification ranged from 2.07 to 2250&#xa0;pg/mL depending on physiological analytes concentration. Extraction recovery averaged 24.3-114.9%, matrix effects were acceptable, and accuracy ranged from 94.4% to 98.9%. No carryover or interferences were detected. Measurement uncertainty remained <15%. This study presents the first LC-MS/MS method partially validated per CLSI criteria for the quantification of 24 steroids in equine serum. The method offers a sensitive and specific alternative to immunoassays and provides a robust tool for equine steroid profiling with potential applications in pregnancy monitoring, placentitis diagnosis, and fetal sex determination.

Animals