Search PubMedSearch

SEARCH · Search PubMed

Results for “environmental design”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

740 records · Page 14Linked to original sources

Application of Three-Dimensionally Printed Surgical Guides in Precise Sacral Tumor Excision and Defect Reconstruction.

OBJECTIVE: Precise resection of sacral tumors remains technically demanding due to their deep anatomical location and close proximity to critical neurovascular structures. Conventional freehand techniques often result in suboptimal resection margins, excessive blood loss, and compromised lumbopelvic stability. This study evaluated whether patient-specific three-dimensional (3D)-printed guiding templates improve surgical accuracy and perioperative outcomes in sacral tumor resection and reconstruction. METHODS: Nineteen patients undergoing en bloc sacral tumor resection (S1-S3 involvement) with spinopelvic reconstruction (2006-2020) were retrospectively analyzed. Patients were divided into a 3D-printing group (n&#x2009;=&#x2009;10) and a conventional freehand group (n&#x2009;=&#x2009;9). In the 3D-printing group, computer-aided design and 3D-printed templates were used for osteotomy, screw placement, and defect reconstruction. Perioperative metrics, surgical accuracy, and complications were compared between groups using Welch's t-test and the Hodges-Lehmann method; oncologic events during follow-up were recorded descriptively. RESULTS: The 3D-printing group demonstrated significantly shorter operative time (456.5&#x2009;&#xb1;&#x2009;62.36 vs. 574.44&#x2009;&#xb1;&#x2009;114.58&#x2009;min, p&#x2009;=&#x2009;0.012), reduced blood loss (4081.40&#x2009;&#xb1;&#x2009;838.99 vs. 5090.0&#x2009;&#xb1;&#x2009;1059.67&#x2009;mL, p&#x2009;=&#x2009;0.034), and fewer fluoroscopic exposures (4.2&#x2009;&#xb1;&#x2009;0.79 vs. 10.0&#x2009;&#xb1;&#x2009;1.58, p&#x2009;<&#x2009;0.001) compared with the conventional group. Osteotomy accuracy was also superior in the 3D-printing group, with significantly lower angular deviation (3.33&#xb0;&#x2009;&#xb1;&#x2009;0.45&#xb0; vs. 6.79&#xb0;&#x2009;&#xb1;&#x2009;2.16&#xb0;, p&#x2009;=&#x2009;0.0012). Postoperative complication rates were comparable (30% vs. 44.4%, p&#x2009;=&#x2009;0.649), but hospital stay was significantly shorter in the 3D-printing group (10.7&#x2009;&#xb1;&#x2009;2.71 vs. 18.11&#x2009;&#xb1;&#x2009;4.01&#x2009;days, p&#x2009;<&#x2009;0.001). CONCLUSION: Patient-specific 3D-printed guiding templates enhance precision in sacral tumor excision and reconstruction, improving surgical efficiency and perioperative safety. This computer-assisted, template-guided approach represents a valuable advancement for complex sacral oncologic surgery.

Humans

Shielding performance and clinical applicability of lead-free materials in computed tomography.

Owing to the high radiation exposure associated with computed tomography (CT) examinations and the image quality degradation caused by conventional radiation shielding materials, this study evaluated the dose reduction performance and image quality maintenance potential of a newly developed lead-free composite shielding material. This material was composed of bismuth, tungsten, tungsten carbide, aluminium, and polyurethane. Phantom-based dose measurements demonstrated that the shielding material achieved dose reduction rates ranging from 17.6% to 37.6%, depending on tube voltage. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and changes in tube current-time product (mAs) under a scout-based automatic exposure control (AEC) protocol were analysed according to the presence or absence of the shielding material across regions. For the clinical evaluation, CT scans were performed on four patients. Furthermore, the images were reviewed to evaluate whether this material affected image quality. The shielding material exhibited radiation reduction levels comparable to those reported in previous studies. SNR and CNR analyses showed minor statistical variations in certain regions; however, most differences were not statistically significant, and even significant differences remained within a range that did not compromise diagnostic image quality. Under the scout-based AEC protocol, the use of the shielding material resulted in less than 1% variation in mAs values. No visually perceptible artefacts or clinically significant image quality degradation were observed. The proposed composite shielding material demonstrated the potential to mitigate some limitations of conventional shielding materials and showed preliminary clinical feasibility as an adjunctive strategy for radiation dose reduction in CT examinations.

Radiation Protection

Virtual surgical planning-assisted versus free-hand head and neck reconstruction: Systematic review, meta-analysis, and a novel classification.

Virtual surgical planning (VSP)-assisted reconstruction is increasingly used as an alternative to conventional free-hand (FH) techniques in mandibular and maxillary free-flap reconstruction. This systematic review and meta-analysis compared clinical outcomes and proposed a Reconstruction Complexity-Completeness classification. PubMed/MEDLINE, Scopus, Web of Science, Google Scholar, and reference lists were searched from inception to 20 June 2026. Comparative studies were eligible. Risk of bias was assessed using RoB 2 or the Newcastle-Ottawa Scale. Random-effects meta-analyses used restricted maximum likelihood estimation and Hartung-Knapp adjustment. Forty-two studies included 2763 patients (1204 VSP; 1559 FH). VSP significantly reduced operative time (33 studies; MD -64.75&#x202f;min, 95% CI -83.51 to -46.00), ischemia time (15 studies; MD -37.40&#x202f;min, 95% CI -48.97 to -25.82), and hospital stay (16 studies; MD -1.75 days, 95% CI -3.43 to -0.08). VSP was associated with significantly lower odds of bony non-union (OR 0.31, 95% CI 0.16-0.59) and malocclusion (OR 0.14, 95% CI 0.03-0.64), whereas flap loss, surgical site infection, and plate exposure did not differ significantly. VSP-assisted reconstruction was associated with improved operative efficiency, shorter hospitalization, and lower odds of bony non-union and malocclusion, while no statistically significant differences were detected in flap loss, surgical site infection, or plate exposure. The proposed classification may support complexity-adjusted reporting and comparison.

Humans

Triazole resistance in clinical Aspergillus fumigatus isolates in India, a multicenter surveillance study.

BACKGROUND: Triazole resistance in Aspergillus fumigatus is a global public health concern associated with treatment failure, notably in invasive aspergillosis. However, population-level data on triazole resistance from India remain limited, with most reports originating from single-center studies. METHODS: We conducted a multicenter surveillance study to assess the prevalence of triazole resistance among clinical A. fumigatus isolates across India. Antifungal susceptibility testing was performed using the CLSI broth microdilution method (M38-Ed3), and molecular characterization was conducted on resistant isolates. A total of 518 isolates were analyzed: 115 prospectively collected from 13 tertiary-care hospitals from 2015-2020, and 403 archived isolates obtained from the National Culture Collection of Pathogenic Fungi (1994-2020). RESULTS: The overall pooled prevalence of non-wildtype isolates was 4.1% for itraconazole (95% CI: 2.54-6.17%), 3.9% for posaconazole (95% CI: 2.39-5.94%), while 1.4% were resistant to voriconazole (95% CI: 0.55-2.77%). One multi-azole-resistant isolate from an immunocompromised, mold-active triazole-na&#xef;ve patient carried the TR34/L98H mutation, suggesting environmental acquisition. Prevalence of resistance did not differ significantly across geographic regions or between public and private sector hospitals. Linear regression analysis revealed a significant temporal increase in median MICs of all three licensed triazoles between 1994 and 2020. Approximately 29% of isolates exhibited amphotericin B MICs exceeding the epidemiological cutoff value; however, the clinical significance of this finding remains uncertain. CONCLUSIONS: Azole resistance among clinical A. fumigatus isolates in India remains uncommon (<5%), supporting the continued use of triazoles as first-line therapy. However, the observed temporal increase in triazole MICs underscores the need for sustained national surveillance to detect emerging resistance trends.

Aspergillus fumigatus

Efficacy and Safety of Psychedelic Microdosing on Psychological Outcomes in Healthy Adults: A Systematic Review and Meta-analysis.

BACKGROUND: Psychedelic microdosing has gained increasing popularity for enhancing mood and cognition, yet its effects on psychological outcomes in healthy adults remain unclear. We aim to evaluate the efficacy and safety of psychedelic microdosing on psychological outcomes in healthy/non-clinical adult&#xa0;population. METHODS: This review was registered in the International Prospective Register of Systematic Reviews (PROSPERO; CRD420251035294). We searched Embase, MEDLINE, and PsycINFO from inception to February 2026 for original studies in healthy adults using sub-hallucinogenic psychedelic doses on separate days. We included randomized studies, nonrandomized prospective studies, cross-sectional studies, and observational longitudinal designs and stratified meta-analyses by design. Random-effects models were used; safety in randomized controlled trials (RCTs) was pooled as risk differences (RDs). Risk of bias was assessed using the Joanna Briggs Institute (JBI) critical appraisal tools appropriate for each study design. RESULTS: 24 studies (3,681 participants) met inclusion criteria, 6 contributed to meta-analyses. RCTs of psilocybin and LSD microdosing showed subjective and neurophysiological effects but minimal impact on cognition, creativity, or sustained mood. Psilocybin altered EEG and speech with little behavioral change, while LSD caused transient mood and minor physiological effects without lasting cognitive or personality benefits. Observational studies indicated mood and personality improvements, likely influenced by expectancy or lifestyle factors. Meta-analyses included two parallel RCTs (3 comparisons; n = 117) and three non-RCT studies (n = 1,013). Adverse event analyses included two RCTs (4 comparisons; n = 109). RCTs showed no clear evidence of immediate symptom reduction: depressive symptoms (SMD = -0.19; 95% CI -0.56, 0.19; I2 = 0%), anxiety (SMD = -0.20; 95% CI -1.11, 0.71; I2 = 82.3%),and stress (SMD = 0.02; 95% CI -0.39, 0.43; I2 = 0%). Non-RCT within-arm estimates were imprecise and heterogeneous for depressive symptoms (SMCC -0.33; 95% CI -0.75, 0.08) and anxiety (SMCC -0.29; 95% CI-0.84, 0.26). Exploratory pooling across all designs suggested decreases in depressive symptoms and stress, while anxiety remained uncertain. Adverse event risks were similar between treatment and control. CONCLUSIONS: Microdosing does not show consistent immediate benefits for depressive, anxiety, or stress symptoms in healthy adults, and evidence from RCTs remains inconclusive. Although improvements were observed in some studies, these effects were not significantly different from placebo. Larger, well-designed RCTs are needed to clarify the efficacy and safety of psychedelic microdosing beyond placebo.

Humans

A hybrid effectiveness-implementation trial to integrate precision skin cancer risk feedback in federally qualified health centers.

BACKGROUND: Skin cancers are the most common type of cancer in the United States, occur in all segments of the population, and are preventable. Our previous research with primary care patients' demonstrated interest in and efficacy of a precision prevention intervention providing feedback on MC1R risk level (higher versus average) in combination with prevention education materials relative to a standard educational intervention. Our current study is a hybrid type 1 effectiveness-implementation trial deployed at six federally-qualified health centers. This paper presents the study protocol. METHODS: A community advisory panel will guide development of study materials and measures. Staff training at each clinic will be completed in-person. Patients will be approached and screened in-person. Those completing genetic testing and the baseline survey will be randomized to the precision versus standard intervention for each risk level with a target sample size of 286 for each combination. Primary outcomes of effectiveness, assessed at 6 and 12&#xa0;months, include a tanning score (5 items assessing intentional and unintentional tanning), number of sunburns, conduct of a skin self-examination, and electronic health record documentation of clinician-patient communication about skin cancer prevention. Effectiveness comparisons will focus on the precision relative to the standard intervention among higher risk participants. Implementation data will be collected to identify barriers and facilitators. RESULTS: Effectiveness and implementation outcomes will be evaluated following study completion. CONCLUSIONS: Results will guide subsequent scale-up of the precision intervention, including modifications of the intervention as well as methods for implementation. CLINICAL TRIALS IDENTIFIER: NCT07222995.

Humans

What's the meta now? More updates on the problems with systematic reviews.

BACKGROUND: Systematic reviews are intended to provide trustworthy evidence synthesis, yet previous iterations of this living review have identified numerous recurring problems in their conduct and reporting. This article presents the third version and second update of the living systematic review examining issues raised across the academic literature. METHODS: Using consistent eligibility criteria and methods from earlier versions, literature searches were updated to May 2025. Eligible meta-research and editorial articles describing problems with systematic reviews were analyzed to identify emerging themes. Additionally, four basic indicators of methodological quality of the included meta-research were presented across review versions. RESULTS: The update included 209 additional articles. Critically low methodological quality and absence of protocols remained among the most frequently reported issues in systematic reviews across disciplines and journals but notably in evidence underpinning clinical practice guidelines. Spin in abstracts and conflicts of interest continued to be common. Apparent improvements in reporting quality were inconsistent, with modest gains in some full-text reporting but persistent deficiencies in abstracts. Authorship diversity of systematic reviews improved in gender representation but remained geographically concentrated in high-income countries, and primary research included in reviews similarly lacked global representativeness. The issue of misalignment between systematic review evidence bases and global burden of disease bring the total number of problems with systematic reviews to 69. Emerging use of automation and artificial intelligence was variably reported. Descriptive comparison of meta-research articles over the three versions of this living review suggests a greater proportion meeting basic quality indicators in more recent updates. CONCLUSION: Across successive updates, problems with systematic reviews remain widespread and consistent rather than isolated. Incremental reporting improvements coexist with persistent concerns about transparency, bias, and representativeness. Future efforts should prioritize evaluating interventions and aligning research incentives to support genuinely trustworthy evidence synthesis.

Humans

Transcriptomic insights into thermal stress reveal physiological trade-off between thermal stress adaptation and reproductive investment in Spodoptera litura.

Spodoptera litura, a highly polyphagous lepidopteran pest, poses a major threat to agricultural productivity due to its remarkable adaptability to diverse environmental conditions. Although heat stress is known to trigger transcriptional reprogramming in insects, the molecular mechanisms underlying thermal stress responses in S. litura remain poorly understood. In the present study, fourth-instar larvae were exposed to acute heat stress (44&#xa0;&#xb0;C) and compared with control conditions (27&#xa0;&#xb1;&#xa0;1&#xa0;&#xb0;C) to investigate heat-induced transcriptional alterations affecting physiology and reproduction. High-quality RNA-Seq data achieved more than 80% mapping efficiency, with a total of 15,782 transcripts were identified. Transcriptome analysis of S. litura larvae showed 323 differentially expressed genes (DEGs), of which 262 genes were significantly upregulated and 61 were downregulated in heat-stressed larvae compared to the control group. The DEGs were associated with stress response, reproduction, signalling, proteostasis, detoxification, oxidative stress, metabolism, development, and chromatin regulation. Heat shock proteins genes, including HSP70, HSP90, and HSP27, together with co-chaperones such as TRET-1, STIP1, and Starvin, were strongly upregulated, indicating enhanced cellular protection against protein damage and oxidative stress under heat stress. Conversely, key reproductive and cell cycle-related genes, including BARR, CAPD2, FEO, CDK2 and MORULA, were significantly downregulated, suggesting reproductive impairment and developmental arrest. RT-qPCR validation corroborated the RNA-Seq findings, demonstrating a heat-induced physiological trade-off that prioritizes survival over reproduction. Consistent with these molecular responses, heat-stressed insects exhibited marked reproductive impairment, including significant reductions in gonadosomatic index, eupyrene sperm bundle count, mating frequency, mating success, female calling behaviour, copulation duration, fecundity, and egg fertility. Collectively, these findings provide comprehensive insights into the molecular basis of thermal adaptation in S. litura and demonstrate that acute heat stress compromises reproductive fitness while activating conserved stress-response pathways that promote short-term survival.

Animals

Physical reconfiguration of limb electrodes for Precordial Bipolar Lead acquisition: Morphological validation against digital subtraction.

BACKGROUND: The V2&#xa0;-&#xa0;V1 Precordial Bipolar Lead (PBL) selectively evaluates the right-to-left retrosternal axis and has shown diagnostic value beyond the standard 12&#x2011;lead electrocardiogram. However, its use has been limited by the need for raw electrocardiographic data and post-processing software. This study evaluated whether a simple physical reconfiguration of limb electrodes could reproduce the digitally derived V2&#xa0;-&#xa0;V1 morphology with sufficient accuracy for clinical application. METHODS: Thirty-seven subjects underwent two sequential 10-s 12&#x2011;lead recordings using a Cardiovit FT-1 electrocardiograph sampled at 1000&#xa0;Hz. In the standard recording, the digital PBL was calculated as V2&#xa0;-&#xa0;V1. In the second recording, the right-arm and left-arm electrodes were repositioned to the V1 and V2 sites so that Lead I directly recorded the retrosternal dipole. Signals were filtered, synchronized, and analyzed using median beats. Morphological agreement was assessed with Pearson correlation on Z-normalized signals, while absolute agreement was evaluated using Lin's concordance correlation coefficient (CCC), intraclass correlation coefficient (ICC (Lewis, 1931; Nehb, 1938 [1,2])), root mean square error (RMSE), and Bland-Altman analysis. RESULTS: Mean Pearson correlation between digital and physical PBL was 0.955 (SD 0.043), with segment-specific correlations of 0.953 (SD 0.054) for QRS and 0.967 (SD 0.052) for ST-T. Lin's CCC and ICC(2,1) were both 0.871 (SD 0.110), and RMSE was 0.091 (SD 0.049) mV. Bland-Altman analysis showed minimal bias (-0.008&#xa0;mV). CONCLUSIONS: Physical acquisition of the V2&#xa0;-&#xa0;V1 PBL achieved high agreement with the digitally derived signal, supporting a simplified analog method for broader clinical implementation.

Humans

Ageing effects on chemical, physical, mechanical, and morphological properties of clear aligners - a systematic review.

BACKGROUND: Clear aligner (CA) therapy has experienced rapid use over the past two decades to treat orthodontic malocclusions. However, evidence on CA material degradation in the oral environment remains limited and often focuses on single brands or isolated material properties. OBJECTIVES: To investigate CA ageing characteristics across different materials and brands and evaluate the chemical, physical, mechanical, and morphological changes following simulated or intraoral ageing. SEARCH METHODS: Five databases (PubMed, Web of Science, MEDLINE [Ovid], ProQuest, and Scopus) were searched to 18 March 2026, with no restrictions. ELIGIBILITY CRITERIA: Studies assessing CA properties after intraoral use or simulated ageing (thermocycling, cyclic loading, or liquid immersion) were included. DATA COLLECTION AND ANALYSIS: Study selection followed PRISMA 2020. RoB was assessed using QUIN for purely in vitro studies, JBI for cohort in vivo studies, and Cochrane RoB 2 for RCTs. Results were synthesised narratively and organised by property domain, as substantial methodological heterogeneity precluded formal meta-analysis. Where protocols were comparable, a simple pooled weighted mean was calculated and presented graphically. RESULTS: Ninety-five studies were included. RoB was low in eight studies, moderate in sixty-two, and high in twenty-five. Chemical composition remained largely stable during ageing, though some brands showed trace elemental release. Physical, mechanical, and morphological properties showed material-dependent deterioration. Pooled discolouration was greatest with coffee (weighted mean &#x394;E&#x2009;=&#x2009;70.9), versus tea (&#x394;E&#x2009;=&#x2009;18.4) and red wine (&#x394;E&#x2009;=&#x2009;11.5), with Invisalign&#xae; consistently exceeding the clinically perceptible threshold. Force decay of 40-90% typically occurred within 48&#xa0;h. Thermoplastic polyurethane (TPU)-based and directly printed aligners (DPAs) generally showed greater susceptibility than polyethylene terephthalate glycol-modified (PETG)-based aligners, though findings on hardness, roughness, and stiffness were inconsistent. CONCLUSIONS: CA materials undergo clinically relevant degradation during use, particularly in TPU-based and DPAs aligners. Clinicians may need to prioritise material-specific protocols, reinforce dietary and cleaning instructions, and consider force decay when determining aligner replacement intervals. PROSPERO number: CRD420251110248.

Humans

Anatomy and Biomechanics of the Deltoid Ligament Complex in Healthy Ankles: Protocol for a Systematic Review and Meta-Analysis.

INTRODUCTION: Up to one in two individuals who have a history of an ankle injury will develop chronic ankle instability, which subsequently increases the risk of osteoarthritis development. Although lateral ankle ligament injuries are the most common, recent research shows that concomitant injuries to the deltoid (medial collateral) ligament complex may be more prevalent than previously recognised. However, the anatomy and biomechanics of the deltoid ligament complex are reported inconsistently in the literature. This systematic review will summarise current evidence on the anatomy and biomechanics of the deltoid ligament complex in healthy adult ankles. METHODS: Searches will be conducted in Scopus, MEDLINE, Embase, CINAHL and SPORTDiscus. Our search strategy will cover terms associated with 'deltoid ligament', 'anatomy' and 'biomechanics'. We will only include dissection and imaging studies published in English that report any of the listed clinically relevant properties of the deltoid ligament in healthy adult human ankles. Two reviewers will independently perform screening and assess study quality using the anatomical quality assessment (AQUA) tool. One reviewer will extract relevant data, which will be independently verified by co-authors. Primary outcomes include band prevalence, length, width, cross-sectional area, maximum and/or failure load and elastic modulus. If three or more studies report a primary outcome, we will conduct a meta-analysis and report findings as pooled means with 95% confidence intervals. If a meta-analysis is not feasible, outcomes will be summarised as a narrative analysis. Measures will be taken during data synthesis to address anticipated methodological heterogeneity across included studies, and pooled estimates will be interpreted with caution. DISCUSSION: This protocol details a systematic review that aims to summarise the anatomy and biomechanics of the deltoid ligament complex. Our findings will inform computational modelling, clinical management and biomechanics for ankle pathologies, as well as identifying research gaps and directions for future research. TRIAL REGISTRATION: PROSPERO: CRD420251142867.

Humans

Comparative efficacy and safety of bi-flanged metal stents versus lumen-apposing metal stents for endoscopic drainage of pancreatic fluid collections: a systematic review and meta-analysis.

INTRODUCTION: Pancreatic fluid collections (PFCs), particularly walled-off necrosis, are common complications of acute pancreatitis that often require endoscopic drainage. Bi-flanged metal stents (BFMS; NAGI; Taewoong Medical, Gyenoggi-do, Korea) and electrocautery-enhanced lumen-apposing metal stents (LAMS; AXIOS, Boston Scientific Corporation, Marlborough, Massachusetts, USA) are frequently used, but comparative data remain limited. This study aims to compare the efficacy and safety of BFMS and LAMS in the endoscopic drainage of PFCs. METHODS: This meta-analysis followed the Cochrane Handbook for Systematic Reviews of Interventions and Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Comprehensive database searches were conducted through November 2024 to identify studies comparing BFMS and LAMS for endoscopic ultrasound-guided drainage of PFCs. Outcomes were pooled using a random-effects model with RevMan Web, and statistical significance was defined as a P value less than 0.05. RESULTS: Three studies ( n &#x2005;=&#x2005;627; 329 BFMS and 298 LAMS) met inclusion criteria. No significant differences were observed between BFMS and LAMS for technical success [odds ratio (OR): 1.16; 95% confidence interval (CI): 0.55-2.43] or clinical success (OR: 0.97; 95% CI: 0.51-1.87). Similarly, there were no differences in walled-off necrosis recurrence (OR: 2.01; 95% CI: 0.17-24.02), number of direct endoscopic necrosectomy sessions (OR: 0.52; 95% CI: 0.05-5.12), or mean number of endoscopic procedures (mean difference: 0.18, 95% CI: 2.08-2.45). Adverse events were also comparable between groups, including bleeding (OR: 0.64), infection (OR: 1.18), stent migration (OR: 1.83), and stent occlusion/dysfunction (OR: 1.71). CONCLUSION: BFMS and LAMS provide equivalent efficacy and safety in the endoscopic ultrasound-guided drainage of PFCs. Either stent type represents a viable therapeutic option. Further large-scale prospective studies are warranted to refine stent selection strategies.

Humans

Comfort and Usability of Digital Versus Conventional Custom-Fit Mouthguards: A Randomized Clinical Trial.

BACKGROUND/OBJECTIVES: The use of mouthguards protects teeth and the supporting tissues against impacts. Digital impressions and 3D-printed models can reduce manufacturing steps and minimize discomfort. This study evaluated the fit, comfort, and usability of custom-made mouthguards, obtained by conventional and digital workflow, in amateur athletes. MATERIALS AND METHODS: Amateur athletes were recruited for this randomized, double-blind, crossover clinical study. Each participant received two 4-mm-thick custom-fit mouthguards made of ethylene vinyl acetate (EVA) sheets using two protocols: conventional impression using alginate to produce dental stone cast (CMP) and intraoral digital scanning to produce 3D-printed resin models (DMP). Each mouthguard was worn during all training and matches over 3&#x2009;months. The order of mouthguard use was randomly assigned. Patient satisfaction with the impression protocol and mouthguard use, model accuracy, and mouthguard fit were assessed. RESULTS: Overall, 46 participants completed the study. The DMP protocol required less execution time (p&#x2009;=&#x2009;0.023), caused less discomfort (p&#x2009;=&#x2009;0.018), anxiety (p&#x2009;=&#x2009;0.008), nausea (p&#x2009;=&#x2009;0.027), difficulty breathing (p&#x2009;<&#x2009;0.001), and unpleasant taste (p&#x2009;=&#x2009;0.006) compared to the CMP protocol. The pain (p&#x2009;=&#x2009;0.971) perceived by the participants was similar in both impression protocols. The CMP-mouthguards were considered to be better fitting by the majority of participants (p&#x2009;=&#x2009;0.027). Between-group comparisons revealed that DMP-mouthguard caused less discomfort immediately postadaptation (p&#x2009;=&#x2009;0.034), with no significant differences observed at 30 or 90&#x2009;days. CONCLUSIONS: The digital workflow demonstrated to be efficient in the fabrication of mouthguards. Digital impression was more comfortable, requiring less execution time, with more accurate printed models and produced mouthguards with reported comfort and fit levels similar to those manufactured conventionally.

Humans

Electrospun Nanofiber Dressings for Diabetic Wounds: From Single-Layer to Intelligent Composite Systems.

Diabetic chronic wounds have become a major challenge for clinical treatment due to their complex pathological microenvironment, including persistent inflammatory response, angiogenesis disorder, excessive oxidative stress, and susceptible infection. Traditional dressings as a passive barrier have difficulty meeting the above multiple treatment needs. Electrospinning technology, with its ability to mimic the fibrous network structure of the natural extracellular matrix (ECM), offers a high specific surface area, controllable porosity, and excellent drug-loading capacity, making it an ideal platform for developing a new generation of multifunctional wound dressings. This article provides a systematic review of the research progress on electrospun nanofiber dressings in the treatment of diabetic wounds, focusing on the design evolution from basic single-layer structures to advanced complex structures and elucidating the mechanisms of action and quantifiable effects of each structural type in addressing specific pathological challenges. We also compared the current status of clinical translation for electrospun dressings with that of other advanced wound care platforms and proposed a standardized preclinical evaluation framework. A large number of research data show that these advanced designs can effectively improve the quality of healing. Finally, this paper points out the challenges faced by this field, such as scalable fabrication, in vivo reliability of smart systems, and long-term biosafety, and provides theoretical basis and technical reference for the design of efficient and intelligent electrostatic spinning diabetic wound dressings.

Nanofibers

CanDo (Canadian Donor Milk) randomised controlled trial: pasteurised human donor milk supplementation in the well-baby unit - protocol.

INTRODUCTION: Mother's milk is the gold standard for feeding newborns. Despite lactation support while in hospital, supplementation rates remain high in Canadian well-baby units at 35-50%. When supplementation is needed, the choice between formula milk and pasteurised human donor milk (donor milk) remains uncertain with a lack of clinical trials to inform this practice. This study aims to compare the effect of supplementing mother's milk with donor milk versus formula in infants at higher risk for supplementation (infants of diabetic mothers, infants born small for gestational age or with a birth weight less than 2.5&#x2009;kg and late preterm infants born between 350/7 and 366/7 weeks gestation). METHODS AND ANALYSIS: This is an ongoing, open-label, single-centre, randomised controlled trial conducted at Mount Sinai Hospital, Toronto, Canada. A total of 112 infants (56 per group) will be randomised to receive donor milk or infant formula as a supplement to mother's milk during their initial hospital stay, when supplementation is deemed necessary by the family and/or healthcare team. The primary outcome is exclusive human milk feeding at 4 months of age. Secondary outcomes include any or exclusive human milk feeding at 1, 2 and 3 months; infant growth and health indicators and breastfeeding self-efficacy. Exploratory outcomes encompass infant temperament; parental mental health (assessed using the State-Trait Anxiety Inventory and Edinburgh Postnatal Depression Scale); milk cortisol concentrations; and informal milk sharing comparing donor milk and formula supplementation. Follow-up includes monthly telephone assessments and a virtual or in-person visit at 4 months post partum. Data will be analysed using intention-to-treat principles. ETHICS AND DISSEMINATION: The CanDo trial has received ethics approval from the Mount Sinai Hospital Research Ethics Board and the University of Toronto. Results will be disseminated through peer-reviewed journals, conference presentations and stakeholder engagement with hospital and public health decision-makers. Findings will address a critical evidence gap regarding the use of donor milk supplementation in well-baby units and may inform future clinical practice and policy in newborn feeding. TRIAL REGISTRATION NUMBER: NCT06315127.

Humans

Multi-centre randomised controlled feasibility trial with embedded process evaluation of a samba percussion intervention for people living with Parkinson's disease: a protocol for the Sparky Samba trial.

INTRODUCTION: Parkinson's disease (PD) is the second most common neurodegenerative disorder, its principal symptom being deterioration of motor function. Current treatment options are limited to symptom management but there is evidence that physical activity can provide motor benefits. More recently there is evidence to suggest that rhythmic auditory stimulation may improve gait and balance in PD. Sparky Samba is a community initiative in South Wales, UK, founded by a person living with PD. Sessions incorporate the following samba rhythms from a trained facilitator and are held weekly in a community setting. METHODS: The Sparky Samba trial is a multi-site, non-blinded, randomised controlled feasibility trial of Sparky Samba compared with activity as usual. A total of 60 people with PD will be randomised 1:1 to take part in a local Sparky Samba group for 12 weeks or continue their normal activities for the same length of time. The primary outcome is feasibility defined by recruitment, retention, data completeness and intervention adherence. Secondary outcomes relating to motor function, cognition, well-being and self-efficacy will also be assessed at baseline and at 12 weeks. Additionally, we will conduct a process evaluation to understand contextual mechanisms surrounding Sparky Samba. This will be achieved through qualitative interviews and structured participant questionnaires following individual trial completion and through structured questionnaires with intervention delivery staff, supplemented with qualitative interviews. ANALYSIS: Feasibility outcomes will be assessed according to pre-defined criteria. For secondary outcomes, means and standard deviations (or medians and IQRs) will be calculated by arm, alongside 95% CIs for change from baseline to 12-week follow-up. Qualitative data will be subject to thematic analysis using NVivo software. ETHICS AND DISSEMINATION: This study received a favourable ethical opinion from the North of Scotland Research Ethics Committee in April 2025 (REC reference 25/NS/0037). Study results will be disseminated through the peer-review literature, the ISRCTN registry and directly to participants, which will be facilitated by the study's public and patient involvement steering group. TRIAL REGISTRATION NUMBER: ISRCTN11861663.

Humans

Physician-Modified Fenestrated Stent-Grafts Planned Using Three-Dimensional Techniques for Complex Aortic Pathology: A Systematic Review and Meta-Analysis.

BACKGROUND: Complex aortic pathology involving the visceral arteries remains a significant therapeutic challenge. Open repair is associated with considerable perioperative risk, particularly in patients with multiple comorbidities, while standard endovascular aneurysm repair (EVAR) is often not feasible because of inadequate proximal sealing zones. Fenestrated and branched endovascular repair (F/BEVAR) represents an established treatment strategy; however, the use of custom-made devices is limited by manufacturing time and availability. Physician-modified stent grafts (PMSGs) have therefore emerged as a pragmatic alternative. Three-dimensional planning techniques have been increasingly used to facilitate accurate graft modification. The aim of this systematic review and meta-analysis was to evaluate the effectiveness and safety of PMSG procedures planned with three-dimensional techniques. Technical success, target vessel patency, early mortality, endoleak occurrence, and reintervention rates were analyzed. METHODS: A systematic search was conducted in the PubMed/MEDLINE and Embase databases. Studies describing the use of physician-modified fenestrated stent grafts planned with three-dimensional tools were included. Meta-analyses were performed using a random-effects model with restricted maximum likelihood estimation. A logit transformation was used for the analysis of proportions. RESULTS: The analysis included five studies involving 172 patients. The estimated weighted mean follow-up duration was 14.9 months. The overall technical success rate was 92.9% (95% confidence interval [CI]: 84.5-96.9%), with low-to-moderate heterogeneity. Target vessel patency was 96.9% (95% CI: 93.6-98.5%). Early mortality was 5.5% (95% CI: 2.1-13.3%). The incidence of endoleaks was 13.3% (95% CI: 5.8-27.4%), with significant heterogeneity among studies. Reinterventions were reported in 6.6% of patients (95% CI: 2.3-17.5%). CONCLUSION: The results indicate that PMSG procedures planned with three-dimensional techniques are associated with a high rate of technical success and preserved patency of target vessels in patients with complex aortic pathology. The observed variability in endoleak and reintervention rates likely reflects differences in anatomical complexity and patient selection among studies. Further prospective studies are needed to confirm long-term outcomes.

Humans

Characterization and application potential of two newly isolated phages targeting the prevalent multidrug resistant Salmonella serovars in China.

The escalating global threat of multidrug resistant (MDR) Salmonella, a foodborne pathogen with animal-derived foods serving as the primary transmission vehicle, underscores the urgent need for effective lytic phages for biocontrol. From 142 environmental and farm samples in Shandong Province, we isolated 103 phages active against MDR S. Enteritidis and S. Typhimurium, which were the most prevalent Salmonella serovars in China. Two Siphoviridae phages vB-SenS-S1 and vB-SenS-SEC2 were selected for further study. With optimal multiplicities of infection (MOIs) of 10-2 (vB-SenS-S1) and 10-5 (vB-SenS-SEC2), both phages exhibited a 20&#xa0;min latent period, yielding burst sizes of 52 and 37 PFU/cell, respectively. They also demonstrated stability across a range of temperatures (50-60&#xa0;&#xb0;C), pH levels (5-11), and after 1&#xa0;h of UV exposure. Genomic analysis identified vB-SenS-S1 (43,002&#xa0;bp, 47.04% GC) and vB-SenS-SEC2 (42,948&#xa0;bp, 47.65% GC) as novel double-stranded DNA phages. Functional annotation confirmed the presence of genes essential for structural assembly, host lysis, and DNA replication/metabolism, and also verified the absence of resistance, virulence, and lysogeny-associated genes. Both phages vB-SenS-S1 and vB-SenS-SEC2 exhibited synergy with colistin and tetracycline. The synergy with colistin was particularly potent, leading to complete bacterial eradication in vitro. The in vivo therapeutic efficacy was further validated in both Galleria mellonella larvae and murine models of MDR Salmonella infection. Combination therapy with vB-SenS-SEC2 and colistin not only dramatically increased survival but also achieved a significant reduction in bacterial burden across multiple visceral organs of infected mice. Moreover, vB-SenS-S1 (108 PFU/mL) completely inhibited MDR Salmonella on chicken meat at 4&#xa0;&#xb0;C and -20&#xa0;&#xb0;C when initial contamination was &#x2264;103&#xa0;CFU/mL. This study not only expands the diversity of Salmonella phages but also highlights their potential as biocontrol agents in both clinical veterinary use and food decontamination, thereby enhancing food quality and safety at both the meat production source and the terminal product.

Animals