Search PubMedSearch

SEARCH · Search PubMed

Search Search PubMed

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

20 recordsLinked to original sources

Determination of 13 per- and polyfluoroalkyl substances in human plasma samples using LC-MS/MS: application to capillary microsamples.

Per- and polyfluoroalkyl substances (PFAS) are chemicals widely applied in industrial processes and highly persistent in the environment, whose extensive use has been linked to adverse health effects. Venous plasma is the conventional matrix for PFAS assessment in blood, and LC-MS/MS is the most used quantification technique. Despite the relevance of this topic, biomonitoring data on human exposure to PFAS in Brazil remain limited. This study validated an LC-MS/MS method for determination of 13 PFAS in human plasma. Blood samples were collected from volunteers by phlebotomy, followed by protein precipitation with acetonitrile containing 1% formic acid (v/v) and solid-phase extraction. Chromatographic separation was achieved on an Acquity UPLC HSS T3 column. The assay was linear over a calibration range of 0.2-20 ng/mL. Intra- and inter-assay precision (CV%) were within the ranges of 2.06-12.0% and 0.25-10.7%, respectively. As for accuracy, results were 89.0-112.9%. Matrix effect ranged from -1.31 to 0.05%. Stability after four freeze/thaw cycles and under autosampler conditions were also confirmed for all analytes. The method was applied to 40 paired venous and capillary plasma samples. Both measures exhibited high correlation (r = 0.926). PFOS was the only compound detected at concentrations ≥0.2 ng/mL (LLOQ) in all samples, with capillary plasma concentrations of 0.85-13.50 ng/mL. In summary, the method showed good validation performance and demonstrated the suitability of capillary plasma samples as an alternative matrix for PFAS quantification.

Humans

Spatially confined electrochemical strategy with DNA-assembled nanogaps for SNP detection.

Accurate detection of low-abundance single nucleotide polymorphisms (SNPs) against a large excess of homologous wild-type sequences requires both selective molecular recognition and effective transduction of small sequence differences into measurable signals. Here, we report a spatially confined electrochemical strategy that couples sequence-selective recognition with size-dependent mass-transport gating. DNA-hybridization-driven self-assembly of gold nanoparticles (AuNPs) forms a three-dimensional self-assembled electrode (3D-SAE) with a DNA-defined interparticle architecture. Competitive probes (SP/WP) convert single-base recognition into distinct molecular-size states: the SNP-associated pathway preferentially triggers a hybridization chain reaction (HCR), generating bulky AuNP-anchored HCR/methylene blue complexes (Au@HCR/MB) with reduced electrochemical accessibility through the porous 3D-SAE, whereas the wild-type pathway does not trigger HCR and maintains a high-current response from more readily accessible MB-containing species. Thus, sequence recognition is translated into a molecular-size difference and subsequently into an electrochemical signal through differential mass transport. Under buffer conditions, the platform achieved a statistically estimated detection limit of ∼0.47 fM and a quantitative range of 1 fM-100 pM. It discriminated a 0.1% mutant abundance in a fragmented genomic-DNA background. The downstream signal-transduction chemistry is enzyme-free and isothermal. This work establishes a mechanistical recognition-size-conversion-mass-transport-gating architecture for electrochemical nucleic acid analysis.

Polymorphism, Single Nucleotide

Development and validation of a novel LC-MS/MS method for simultaneous quantification of fidaxomicin and metabolite (OP-1118) from feces for gut pharmacobiome studies.

Fidaxomicin is a first-line antibiotic for treating Clostridioides difficile infection. While it has low systemic absorption and reaches high colonic concentrations, it is hydrolyzed to a less active metabolite, OP-1118. Few studies have completely described critical experimental details of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for quantifying fecal fidaxomicin and OP-1118. This study developed and validated a simple, fast, and sensitive LC-MS/MS method to quantify fidaxomicin and OP-1118 in human and mouse feces. This method simplified fecal sample preparation without the use of solid phase extraction and optimized LC-MS/MS parameters. A broad working range (0.3-1000 ng/ml) in both diluted human and murine fecal matrices was achieved with good intra- and inter-day accuracy (93-107%), precision (1-7%), and recovery (70-105%) as well as little IS-normalized matrix effects. This method was utilized to quantify fidaxomicin and OP-1118 in human and murine fecal samples. This novel method was simple, fast, sensitive, and accurate in analyzing fecal fidaxomicin and OP-1118 and could be deployed to facilitate gut pharmacobiome research.

Feces

Vortex-assisted liquid-liquid microextraction based on natural deep eutectic solvents for the determination of pyrethroid pesticides in urine.

A novel, facile, and environmentally friendly analytical method was developed based on vortex-assisted liquid-liquid microextraction and high-performance liquid chromatography with diode-array detection for detecting pyrethroid pesticides (PPs) in urine. Natural deep eutectic solvents (NADESs) were prepared using plant essential oil-derived monoterpenoids (thymol, carvacrol, and menthol) combined with aromatic primary alcohols (benzyl alcohol, phenethyl alcohol, and phenylpropyl alcohol) as hydrogen bond donors and acceptors. These solvents served as environmentally benign extraction media, thereby avoiding the use of conventional volatile, toxic organic solvents. NADESs are naturally derived, easy to prepare, biodegradable, and environmentally friendly solvents. Hydrophobic and π-π interactions between the NADESs and PPs may contribute to enhancing the affinity of PPs toward the NADESs phase. Vortex technology, accelerating mass transfer between the sample and extractant phases, enables fast extraction of PPs. Under optimized conditions, the method achieved a low detection limit (0.002 mg L-1), satisfactory precision with relative standard deviations (0.3%-2.4%), and acceptable recovery (80.7%-86.2%). The method demonstrated excellent performance in urine analysis and was feasible as a facile and green strategy for monitoring the content of PPs in biological matrices and assessing exposure risk.

Liquid Phase Microextraction

Simultaneous determination of imiquimod and terbinafine in skin permeation studies: Validation of a liquid chromatography method with fluorescence detection.

Chromoblastomycosis is a chronic, neglected subcutaneous mycosis posing significant therapeutic challenges. A topical strategy combining terbinafine (TBF), an antifungal, with imiquimod (IMQ), a TLR-7/8 agonist immunomodulator, has emerged a promising alternative. However, no validated analytical method is currently available to simultaneously quantify both drugs in skin, which is crucial for novel formulation development. This study reports the development and validation of a simple HPLC method with fluorescence detection (excitation 236 nm, emission 340 nm) for the simultaneous determination of TBF and IMQ extracted from porcine skin. Separation was achieved on a C8 reversed-phase column (125 × 4.0 mm, 5 μm) using a mobile phase of methanol and water (60,40, v/v), both containing 0.1% formic acid at a flow rate of 0.8 mL/min. The method showed excellent linearity (r > 0.999) over 0.01-1.0 μg/mL for IMQ and 0.1-2.0 μg/mL for TBF. Intra- and inter-day precision demonstrated coefficients of variation below 5%, and recovery rates from skin (79-105%) confirmed accuracy. Limits of detection were 0.001 μg/mL for IMQ and 0.004 μg/mL for TBF, with quantification limits of 0.02 μg/mL and 0.16 μg/mL, respectively. This selective, sensitive, and reproducible method represents a valuable analytical tool for supporting the development and quality control of topical formulations for chromoblastomycosis and other fungal skin diseases.

Animals

Quantifying the aromatic amino acid metabolome: UPLC-MS/MS analysis of aromatic amino acids and their host and co-metabolites in plasma.

Aromatic amino acids (AAAs), tryptophan, phenylalanine, and tyrosine along with their pathway metabolites have been implicated in the pathogenesis of diseases ranging from cardiovascular, neurological, inflammatory, and cancer diseases, among others. As such, the measurement of the primary AAAs, their host pathway metabolites, and microbiome derived co-metabolites in blood can provide a sensitive reflection of systemic health. The aim of the study was to develop a method for the quantification of 17 metabolites, the three AAAs and various of their metabolites in plasma using a high-throughput ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method. The method demonstrated a dynamic range (1 to 16,700 ng/mL), with detection limits (LOD) as low as 0.05 ng/mL. Quantification limits ranged from 3 to 5019 ng/mL (LLOQ) and up to 16,700 ng/mL (ULOQ). Recovery at LQC, MQC, and HQC was satisfactory and consistent across most metabolites, with significant matrix effects observed only for 4-ethylphenol sulfate. Furthermore, intra and inter-day accuracy and precision met all acceptance criteria at all quality control concentrations for most of the metabolites. Measurement of NIST SRM 1950 showcased the method's accuracy for most of the metabolites. Finally, the method was applied on the analysis of plasma samples from 55 individuals (13 males and 42 females) providing information on AAAs and their pathway metabolites relevant concentrations in human plasma.

Amino Acids, Aromatic

An RPA-assisted homogeneous electrochemical DNA sensor for on-site eDNA detection toward early warning of crown-of-thorns starfish outbreaks.

Crown-of-thorns starfish (COTS) outbreaks seriously threaten coral reef ecosystems, while conventional monitoring approaches are time-consuming and often lack sufficient sensitivity for early warning. Existing electrochemical DNA sensors usually require complex electrode-surface immobilization procedures, which can lead to uneven probe distribution, significant steric hindrance, and poor stability. Meanwhile, the low concentration of environmental DNA (eDNA) in marine environments further complicates detection. To overcome these challenges, this study developed a homogeneous electrochemical DNA sensor assisted by recombinase polymerase amplification (RPA) for COTS eDNA detection. Target DNA was first amplified by RPA, and the amplification products were then hybridized in solution with capture probe (CP)-modified magnetic beads (MB) and biotin-labeled signal probe (SP) to form sandwich-structured MB complexes. These complexes were subsequently magnetically enriched and immobilized on the electrode surface for electrochemical signal readout. Under optimized conditions, the sensor displayed a linear response to COTS genomic DNA from 3.77 fg/μL to 1 ng/μL, with an LOD of 2.02 fg/μL and an LOQ of 3.77 fg/μL. The sensor was applied to Xisha Islands samples, and the results agreed with droplet digital PCR (ddPCR) (P > 0.05), demonstrating its potential for sensitive and reliable on-site COTS eDNA detection.

Animals

Selective monitoring of trace-level catechin and myricetin in herbal and aqueous matrices using magnetic MIP-DSPME: Optimization via design of experiments.

A novel dispersive solid-phase microextraction approach utilizing a magnetic molecularly imprinted polymer (MMIP) integrated with HPLC-UV detection was developed for the concurrent quantification of catechin and myricetin in herbal extracts and aqueous samples. The sorbent was engineered as a core-shell nanocomposite, consisting of a selective polymer layer deposited onto Fe3O4@SiO2-APTMS magnetic nanoparticles. Dual-template imprinting using catechin and myricetin generated complementary binding cavities within the polymer framework. Experimental variables influencing extraction were systematically screened and subsequently optimized. A Plackett-Burman design was first applied to identify the most influential factors, with pH and sorption time identified as the dominant variables. These parameters were subsequently fine-tuned using a central composite design, and the optimization process was completed in only 30 experimental runs. The sorption characteristics of the imprinted sorbent (MMIP) were compared with those of its non-imprinted counterpart (MNIP). The MMIP demonstrated markedly higher maximum binding capacities (Qmax), reaching 119.3 mg g-1 for myricetin and 112.1 mg g-1 for catechin, whereas the corresponding values for the MNIP were 32.55 and 32.08 mg g-1, respectively. Moreover, the affinity constants (KL = 0.760-0.950 L mg-1) were approximately 2.3-fold higher for the MMIP, confirming its stronger and more selective interactions with the target analytes. The selectivity coefficients for the targeted flavonoids relative to structurally related compounds, including ferulic acid, p-coumaric acid, melatonin, and curcumin, exceeded 3.5 for the MMIP, whereas the corresponding values for the MNIP were close to 1.1, demonstrating the high molecular recognition capability of the imprinted sorbent. Method validation demonstrated limits of detection (LODs) of 0.33-0.59 ng mL-1 and limits of quantification (LOQs) of 1.10-1.96 ng mL-1, and excellent linearity over the concentration range of 5.0-5500 ng mL-1 (R2 > 0.998). The method achieved recoveries of 93.96% to 105.69% with RSDs below 5.5%, while the preconcentration factors ranged from 209 to 229. Furthermore, the sorbent retained more than 95% of its extraction efficiency after four consecutive reuse cycles and more than 80% after six cycles, demonstrating excellent stability and reusability. The proposed method was successfully applied to the analysis of six medicinal plant extracts and water samples, showing negligible matrix interference and superior sensitivity, selectivity, and operational simplicity compared with conventional solid-phase extraction methods.

Flavonoids

Validated UPLC-MS/MS quantification and intracellular PK-PD Modeling of periplocin-related cardiac glycosides in H/R-injured H9c2 cells.

Reliable intracellular quantification is essential for characterizing the target-site disposition and exposure-response relationships of bioactive natural products. In this study, an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the simultaneous determination of periplocin and four related cardiac glycoside metabolites in H9c2 cell lysates. Acceptable linearity, precision, recovery, and stability were achieved for intracellular quantification. Cells were treated with each compound at 50 μM, and intracellular concentrations and cell viability were monitored over 48 h. In hypoxia/reoxygenation (H/R) -injured cells, the time to maximum intracellular concentration was shortened for all five compounds, indicating altered cellular disposition under injury conditions. Cell viability was improved by all compounds during the observation period. Pharmacokinetic-pharmacodynamic (PK-PD) integration was performed using a sigmoid Emax model, and acceptable model fits were obtained, with Akaike information criterion (AIC) values ranging from 79.22 to 130.46. Low apparent EC50 values were estimated under this single-dose design, whereas the estimated Ke0 values suggested delayed equilibration with the effect compartment. These findings indicate that sustained cytoprotective responses can be produced by periplocin and related metabolic markers in injured cardiomyocytes. This intracellular bioanalytical strategy provides a quantitative approach for linking cellular exposure to pharmacodynamic response and may support further evaluation of periplocin-related cardiac glycosides.

Tandem Mass Spectrometry

Improved comprehensive profiling of fecal bile acids through chemical derivatization combined with HPLC-MS/MS analysis.

Bile acids (BAs) facilitate the digestion and absorption of fats and influence lipid and glucose homeostasis, making them potential therapeutic targets for obesity and related metabolic disorders. The liver and intestinal microbiota modify BAs structurally, generating diverse chemical forms and isomers. Comprehensive profiling of the BA pool is critical for understanding their key biological functions and as a therapeutic approach for related diseases. High-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) is usually chosen as the preferred method for BA detection due to the complex chemical structures, the wide range of actual concentrations and the complexity of fecal sample matrices. However, free BAs are difficult to ionize, resulting in low detection signals and a lack of characteristic structural fragments to assist in structural identification. In this method, the labeling reagent (2-aminoethyl) trimethylammonium (AETMA) is employed to label the carboxyl group of BAs. Compared with underivatized BAs, the detection sensitivity of unconjugated BAs was enhanced by 25-180 fold, while that of conjugated BAs increased by 6-160 fold. It also generates unique fragment ions and enhances MS response, facilitating the discovery of potential BAs. Methodological parameters were validated using 38 BAs as representatives. Through methodological validation, it was verified that the precision, recovery, matrix effect and stability parameters of the method met acceptable criteria. We also identified 61 confirmed BAs and 55 additional candidate BAs in human pooled fecal samples. It has been successfully applied to fecal BA analysis in obese populations, providing valuable insights into potential therapeutic strategies for obesity.

Tandem Mass Spectrometry

Development and validation of a liquid chromatography-tandem mass spectrometry method for the quantification of twenty-five steroids in equine serum.

Steroids are potential biomarkers for monitoring equine pregnancy. However, immunoassays currently used for their quantification suffer from cross-reactivity and limited specificity, thus requiring more accurate methods. This study reports the development and validation of a robust liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous quantification of 25 steroids covering the main biosynthetic pathways of progestogens, corticosteroids, androgens, and estrogens. Steroids were extracted by protein precipitation followed by evaporation, derivatization, and reconstitution before LC-MS/MS analysis. A surrogate matrix was used for calibration and validation to avoid endogenous interference. Validation was performed according to and partly adapted from Clinical and Laboratory Standards Institute guidelines (CLSI), including linearity, trueness, precision, limits of detection and quantification, measurement uncertainty, recovery, matrix effects, carryover, selectivity, and stability. Calibration curves were fitted using the best-performing weighted linear or quadratic regression model, yielding excellent linearity (R2&#xa0;>&#xa0;0.990), trueness between -9.0% and 2.3%, and intra- and inter-day precision <6.3%. Lower limits of quantification ranged from 2.07 to 2250&#xa0;pg/mL depending on physiological analytes concentration. Extraction recovery averaged 24.3-114.9%, matrix effects were acceptable, and accuracy ranged from 94.4% to 98.9%. No carryover or interferences were detected. Measurement uncertainty remained <15%. This study presents the first LC-MS/MS method partially validated per CLSI criteria for the quantification of 24 steroids in equine serum. The method offers a sensitive and specific alternative to immunoassays and provides a robust tool for equine steroid profiling with potential applications in pregnancy monitoring, placentitis diagnosis, and fetal sex determination.

Animals

Direct background subtraction LC-MS/MS assay for human plasma progesterone: Full validation and comparative application.

OBJECTIVE: To develop and validate a liquid chromatography-tandem mass spectrometry method based on direct background subtraction for the quantification of endogenous progesterone in human plasma. METHODS: Protein precipitation was used for sample preparation with deuterated progesterone as the internal standard. Chromatographic separation was performed on an ACQUITY C18 column using gradient elution with 0.1% formic acid in water and acetonitrile at a flow rate of 0.3&#xa0;mL/min. Mass spectrometry was operated in positive electrospray ionization mode with multiple reaction monitoring. Instead of using analyte-stripped matrix or surrogate matrix, authentic plasma was directly used for all validation experiments. Quantitation was achieved by subtracting the background signal, and results were compared with those from the classical method using stripped matrix. RESULTS: Excellent linearity was achieved over 0.1-100&#xa0;ng/mL (R2&#xa0;&#x2265;&#xa0;0.99). Precision, accuracy, recovery, matrix effect, and stability all met FDA and ICH M10 acceptance criteria. Compared with the classical method, the bias in Cmax and AUC0-t was within &#xb1;15%, indicating no significant difference between the two methods. CONCLUSION: The direct background subtraction method avoids laborious preparation of blank matrix, eliminates matrix effect discrepancies, and is simple, efficient, and low-cost. It can serve as a general strategy for endogenous substance determination.

Humans

A versatile reversed-phase liquid chromatography charged aerosol detection method for streamlined monitoring of QS-21 content and stability in liposomal adjuvant formulations.

Identifying and quantifying an active adjuvant along with its degradants in drug formulations is essential for ensuring the safety and efficacy of the drug product. QS-21 is a potent adjuvant that is being evaluated in several clinical trials and is currently formulated in licensed vaccines that protect against shingles, malaria, and RSV. In aqueous environments, QS-21 is subject to hydrolytic degradation that is influenced by pH and temperature, resulting in the formation of a degradant known as QS-21 Hydrolyzed Product, QS-21 HP, which can occur during manufacturing and/or prolonged storage. The intact QS-21 and QS-21 HP induce distinct immune response profiles, making it critical to monitor the degradation of QS-21 in vaccine adjuvant formulations. To date, there has been a paucity of reliable assays for QS-21, its isomers, and degradant QS-21 HP in liposomal adjuvant formulations available that can be transferred seamlessly in quality control (QC) environments. Herein, we introduce a simple and QC-friendly liquid chromatography coupled to a charged aerosol detector (LC-CAD) enabled by stationary phase screening combined with in silico method development optimization. The method exploits 2.7&#xa0;&#x3bc;m fused-core phenyl hexyl particles, ensuring its versatility in standard and ultra-high pressure LC systems. This approach demonstrates a high correlation between predicted retention time (RT) and experimental outcomes with overall &#x2206;RT&#xa0;<&#xa0;4%. In addition, this assay shows great linearity, precision, specificity, and accuracy to advance process development characterization of new vaccine formulations.

Liposomes

Development and validation of an LC-MS/MS method for the quantification of the KRASG12C inhibitor divarasib.

Divarasib is a newly developed covalent KRASG12C inhibitor, currently under clinical investigation in a phase 3 trial in patients with non-small cell lung cancer (NSCLC). At the moment, very limited pharmacokinetic data are publicly known. However, obtaining more insight into the pharmacokinetic properties of divarasib is important, since this may provide a better understanding of its efficacy and safety risks. Pre-clinical studies have been performed in mouse models to evaluate the effect of drug transporters and drug-metabolizing enzymes on the plasma exposure and tissue distribution of divarasib. Therefore, a reliable quantification method is required. To our knowledge, no bioanalytical assay of divarasib has been published yet. Therefore, in this study we developed and validated an assay to quantify divarasib in human plasma and in eight different mouse-related matrices, and partially in mouse plasma, using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method was initially evaluated over a concentration range of 1-10,000&#xa0;nM. However, due to carry-over observed at 10,000&#xa0;nM, the validated calibration range was established at 1-2000&#xa0;nM, with matrix-dependent LLOQs of 1-10&#xa0;nM. Erlotinib was used as an internal standard and acetonitrile was utilized to perform protein precipitation as sample pretreatment. Divarasib demonstrated stability in human plasma and in mouse plasma and tissue homogenates under various experimental conditions. A pilot in vivo study showed the applicability of our validated LC-MS/MS method. Ongoing clinical trials may collect plasma samples, and this developed method enables quantification of divarasib in both mouse and human plasma samples.

Animals

Dual signal-enhanced immunochromatographic test strip based on Au@PtNPs: From sensitive detection of thiamethoxam to multiplex pesticide screening in vegetables.

Immunochromatographic test strip (ICTS) is a rapid analytical technique widely used in environmental and food detection owing to its merits of simple operation and short analysis time. Herein, three-dimensional nanoflower-structured gold&#x2011;platinum nanoparticles (Au@PtNPs) were synthesized via a seed-growth method. Compared with conventional gold nanoparticles (AuNPs), Au@PtNPs exhibited stronger signal intensity, excellent catalytic performance, and efficient antibody binding efficiency. Colorimetric Au@PtNPs-ICTS and catalytic colorimetric Au@PtNPs-ICTS were developed for the sensitive detection of thiamethoxam (THI) in vegetables. The limits of detection (LODs) for colorimetric Au@PtNPs-ICTS and catalytic colorimetric Au@PtNPs-ICTS quantitative analysis were 0.18&#xa0;ng/mL and 0.093&#xa0;ng/mL, respectively, representing approximately 3-fold and 6-fold improvement compared to AuNPs-ICTS (0.56&#xa0;ng/mL). Furthermore, highly sensitive detection of multiple pesticide residues (chlorpyrifos, acetamiprid, and imidacloprid) was achieved by replacing the corresponding target antigens and antibodies, which further verified the universality of this immunochromatographic strategy.

Thiamethoxam

A smartphone-integrated Pt@Cu-HCF nanozyme-based paper sensor for on-site determination of total antioxidant capacity in marine oils.

Total antioxidant capacity (TAC) serves as a key indicator for evaluating the nutritional quality of foods. In this study, we designed a platinum-embedded copper hexacyanoferrate (denoted as Pt@Cu-HCF) nanozyme that exhibits high oxidase-like activity, efficiently catalyzing the oxidation of chromogenic substrates to generate robust colorimetric signals. Antioxidants quench hydroxyl radicals (&#x2219;OH) produced during the catalytic process, leading to a concentration-dependent suppression of the color signal. Leveraging this mechanism, a smartphone-integrated, colorimetric paper sensor for on-site TAC quantification was developed, using vitamin E as the calibration standard. The sensor was applied to determine TAC in fish oil, algal oil, and krill oil, demonstrating a linear response range of 9.78-312.5&#xa0;&#x3bc;M and a limit of detection (LOD) of 6.41&#xa0;&#x3bc;M. Validation using real-world marine oil samples showed excellent agreement with a commercial assay kit, confirming the reliability and practical applicability of this portable sensor for TAC measurement in complex biological matrices.

Antioxidants

Morphology-engineered NiFe@C nanocages boosting electrochemical quantification of ractopamine in meat samples.

It is essential to acquire efficient electrocatalysts to develop ractopamine (RAC) electrochemical sensors. Herein, we report the synthesis of a series of carbon coated NiFe alloy nanostructures (e.g., NiFe@C nanoparticles, nanocubes and nanocages) using NiFe Prussian blue analogue (PBA) as the precursor. The NiFe@C nanocages exhibited the best electrocatalytic performance for RAC sensing. This is attributed to the embedded NiFe alloy nanoparticles that provide abundant active sites, and the unique nanocage structure facilitates electron transfer pathways while offering a high specific surface area. The resulting sensor achieves a low detection limit (LOD) of 54&#xa0;nM (S/N&#xa0;=&#xa0;3) within a linear range of 0.2-12&#xa0;&#x3bc;M. Moreover, the sensor demonstrates good reproducibility, stability, and excellent long-term stability. Practical applicability was confirmed in meat samples, yielding satisfactory recovery rates ranging from 98% to 108%. A feasible strategy was introduced herein for rational design of metal@carbon electrocatalysts.

Phenethylamines

Selective and sensitive colorimetric sensing of carbosulfan based on BiO2-x/Bi2O2.75 nanosheets with excellent haloperoxidase-like activity.

The development of colorimetric methods based on directly inhibiting nanozyme activity for pesticide detection has attracted considerable attention. In this study, we report a novel colorimetric sensing strategy utilizing BiO2-x/Bi2O2.75 nanosheets (BiO2-x/Bi2O2.75 NSs) with haloperoxidase (HPO)-like activity for the rapid and sensitive detection of carbosulfan (CBS) in foods. Oxygen-vacancy-rich BiO2-x/Bi2O2.75 NSs with HPO-like activity were rationally constructed. Kinetic studies revealed a remarkable Michaelis-Menten constant (Km) of 0.014&#xa0;mM for I-, indicating a higher affinity for iodide ions than other reported HPO-like nanozymes, as evidenced by its lower Km. Under acidic conditions, CBS tends to be hydrolyzed to produce reductive sulfide species, which directly inhibit the iodoperoxidase-like activity of BiO2-x/Bi2O2.75 NSs, enabling selective detection with a limit of detection (LOD) of 0.18&#xa0;&#x3bc;g/mL and a linear range of 0.20-100&#xa0;&#x3bc;g/mL. When the concentration of interfering pesticides and substances was 5 times that of CBS, the sensor remained unaffected, exhibiting excellent stability and specificity. This work contributes to the detection of CBS in complex food matrices, bridging the application gap of HPO-like nanozymes in pesticide detection and providing a promising method for food safety detection.

Colorimetry