A programmable pre-emphasis system.

Abstract

MRI systems often use magnetic field gradient and shim pulse-shaping networks (pre-emphasis) to correct for magnetic field distortions caused by eddy currents. A pre-emphasis system that uses up to 16 fixed resistor-capacitor (RC) time constants per channel with programmable amplitude coefficients is described. The magnetic fields induced by the pre-emphasis RC time constants serve as a set of basis functions for compensating eddy-current fields induced by the gradient set. The resultant time-varying magnetic field gradient accurately reflects the gradient specified by the pulse programmer. Reductions in eddy-current fields are demonstrated for actively shielded and unshielded gradient sets.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H M Gach, I J Lowe, D P Madio, A Caprihan, S A Altobelli, D O Kuethe, E Fukushima. 1998. A programmable pre-emphasis system.. https://doi.org/10.1002/mrm.1910400313

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts

MRI screening of the cerebellopontine angle and inner ear with fast spin-echo T2 technique.

In patients with unilateral hearing loss and dizziness it is important to rule out a cerebellopontine angle process. This is often done by audiological and otoneurological investigations. However, in many cases we must rely on the imaging of the temporal bone and the cerebello-brainstem area. The paper has presented the three dimensional (3D) Fast Spin-Echo (FSE) T2 weighted, 0.7 mm thick MR images, which in addition to being quick, does not require the use of expensive contrast material. Between September 1996 and November 1997, 152 patients with unilateral hearing loss and/or balance disorders were investigated. In normal cases the 7th and 8th nerves could be followed accurately from the brainstem to the internal auditory meatus. The found tumors were hypointense compared to the cerebrospinal fluid and could be outlined with reasonable accuracy even without gadolinium contrast. The inner ear had high signal, like cerebrospinal fluid. The patency of the cochlea could be estimated accurately. Thus, 3D FSE T2 weighted images can reliably differentiate between patients with and without pathologies of the cerebellopontine angle. The use of gadolinium contrast could be avoided in most of the cases, but contrast is necessary for differential diagnostic purposes in patients with alterations in the cerebellopontine angle or in doubtful cases.

Artifacts

The use of modified primers to eliminate cycle sequencing artifacts.

Cycle sequencing is the workhorse of DNA sequencing projects, allowing the production of large amounts of product from relatively little template. This cycling regime, which is aimed at linear growth of the desired products, can also produce artifacts by exponential amplification of minor side-products. These artifacts can interfere with sequence determination. In an attempt to allow linear but prevent exponential growth of products, and thus eliminate artifacts, we have investigated the use of primers containing modified residues that cannot be replicated by DNA polymerase. Specifically, we have used primers containing 2'- O -methyl RNA residues or abasic residues. Oligomers consisting of six DNA residues and 20 2'- O -methyl RNA residues, with the DNA residues located at the 3'-end, primed as efficiently as DNA primers but would not support exponential amplification. Oligonucleotides containing fewer DNA residues were not used as efficiently as primers. DNA primers containing a single abasic site located six residues from the 3'-end also showed efficient priming ability without yielding exponential amplification products. Together these results demonstrate that certain types of modified primers can be used to eliminate artifacts in DNA sequencing. The technique should be particularly useful in protocols involving large numbers of cycles, such as direct sequencing of BAC and genomic DNA.

Artifacts