Transforming NMR data despite missing points.

Some NMR experiments produce data with several of the initial points missing. The inverse discrete Fourier transform (IDFT) assumes these points are present so the data cannot be so transformed without artifact-ridden results. This problem is often particularly severe when projection imaging with free-induction decays (FIDs). This paper compares recent methods for obtaining a projection from incomplete data and elaborates on their strengths and limitations. One method is to write the transform that would take the desired projection to the truncated data set, and then solve the matrix equation by singular value decomposition. A second replaces the missing data with zeros, so that an IDFT produces a projection with unwanted artifacts. Then one solves the matrix equation that takes the desired projection to the artifact-ridden projection. A third uses the same artifact-ridden projection, but fits the region outside the bandwidth of the sample with as many sinusoidal functions as there are missing data. The coefficients of these functions are estimates of the missing data, and the projection is obtained by transforming the completed FID or subtracting the extrapolation of the fitted curve from the region containing the object. We show that when all three methods are applicable, they theoretically produce the same result. They differ by ease of implementation and possibly by computational errors. They give a result similar to that of the previous method that iteratively corrects the FID and projection after repeated IDFTs and DFTs. We find that one can obtain a projection despite missing a substantial number of data.

Artifacts↗

Ultra-fast velocity imaging in stenotically produced turbulent jets using RUFIS.

A method for rapidly producing velocity images is presented. This sequence combines a modified bipolar gradient pulse to magnitude encode the velocity with the rotating ultra-fast imaging sequence (RUFIS) to image the encoded spins. Velocity encoding is done in 3 msec, and RUFIS acquires 32 projections in 8 msec. The method is applied to turbulent jets associated with a 75% stenosis in a 15-mm inner diameter glass pipe. Data is acquired upstream and downstream from the stenosis for Reynolds numbers from 560 to 3750. In addition, a robust method of reconstructing the unobserved short time region of a free induction decay is presented and incorporated into the image processing.

Image Processing, Computer-Assisted↗

A programmable pre-emphasis system.

MRI systems often use magnetic field gradient and shim pulse-shaping networks (pre-emphasis) to correct for magnetic field distortions caused by eddy currents. A pre-emphasis system that uses up to 16 fixed resistor-capacitor (RC) time constants per channel with programmable amplitude coefficients is described. The magnetic fields induced by the pre-emphasis RC time constants serve as a set of basis functions for compensating eddy-current fields induced by the gradient set. The resultant time-varying magnetic field gradient accurately reflects the gradient specified by the pulse programmer. Reductions in eddy-current fields are demonstrated for actively shielded and unshielded gradient sets.

Artifacts↗

Ultra-fast imaging using low flip angles and FIDs.

A new ultra-fast imaging technique that does not place extreme demands on the speed of the gradient system is described. When used with comparable MRI systems, the rotating ultra-fast imaging sequence (RUFIS) can acquire images 4 to 5 times faster than gradient-moment nulled EPI and more than twice as fast as DUFIS, OUFIS, or BURST techniques. Because the technique uses free induction decays instead of echoes, it can be made particularly insensitive to effects of motion, flow, and diffusion. Preliminary images of turbulent flow are presented to demonstrate this insensitivity. However, with appropriate encoding, flow effects may be imaged.

Algorithms↗

A novel eddy current compensation scheme for pulsed gradient systems.

We describe a modified pre-emphasis network that uses a number of fixed time constants, only whose amplitudes are adjustable. In comparison with variable time constant pre-emphasis networks we have used, the fixed time constant network is more effective and easier to set on the fly. We have further developed a method to set the fixed time constant network mathematically using a linear least squares technique.

Algorithms↗

On the feasibility of MRI-guided focused ultrasound for local induction of gene expression.

Gene therapy is a promising approach to the treatment of many forms of disease, including cancer. Of critical concern in its implementation is the ability to control the location, duration, and level of expression of the therapeutic gene. Here, we propose the use of local heat in combination with a heat-sensitive promoter to help accomplish this. Certain members of the family of heat shock protein (hsp) promoters display a regulation that depends strongly on temperature. We present a study of natural hsp70 induction in rat leg by MRI-guided focused ultrasound to investigate the hsp70 promoter as a possible candidate for use in control of gene expression with local heat. A temperature increase of 5-8 degrees C in the focal region for 45 minutes led to a differential expression of the hsp70 mRNA between the focal region and the surrounding tissue ranging from a factor of 3 to 67.

Animals↗