Search PubMed⌕ Search

Biomedical subjects

A Caprihan

Publications and source records attributed to A Caprihan.

At least 19 recordsLinked to original sources

Pulsed gradient spin echo nuclear magnetic resonance imaging of diffusion in granular flow

We derive the formalism to obtain spatial distributions of collisional correlation times for macroscopic particles undergoing granular flow from pulsed gradient spin echo nuclear magnetic resonance diffusion data. This is demonstrated with an example of axial motion in the shear flow regime of a 3D granular flow in a horizontal rotating cylinder at one rotation rate.

Journal Article↗

Correlation time and diffusion coefficient imaging: application to a granular flow system.

A parametric method for spatially resolved measurements for velocity autocorrelation functions, R(u)(tau) = , expressed as a sum of exponentials, is presented. The method is applied to a granular flow system of 2-mm oil-filled spheres rotated in a half-filled horizontal cylinder, which is an Ornstein-Uhlenbeck process with velocity autocorrelation function R(u)(tau) = e(- ||tau ||/tau(c)), where tau(c) is the correlation time and D = tau(c) is the diffusion coefficient. The pulsed-field-gradient NMR method consists of applying three different gradient pulse sequences of varying motion sensitivity to distinguish the range of correlation times present for particle motion. Time-dependent apparent diffusion coefficients are measured for these three sequences and tau(c) and D are then calculated from the apparent diffusion coefficient images. For the cylinder rotation rate of 2.3 rad/s, the axial diffusion coefficient at the top center of the free surface was 5.5 x 10(-6) m(2)/s, the correlation time was 3 ms, and the velocity fluctuation or granular temperature was 1.8 x 10(-3) m(2)/s(2). This method is also applicable to study transport in systems involving turbulence and porous media flows.

Diffusion↗

Imaging obstructed ventilation with NMR using inert fluorinated gases.

We partially obstructed the left bronchi of rats and imaged an inert insoluble gas, SF(6), in the lungs with NMR using a technique that clearly differentiates obstructed and normal ventilation. When the inhaled fraction of O(2) is high, SF(6) concentrates dramatically in regions of the lung with low ventilation-to-perfusion ratios (VA/Q); therefore, these regions are brighter in an image than where VA/Q values are normal or high. A second image, made when the inhaled fraction of O(2) is low, serves as a reference because the SF(6) fraction is nearly uniform, regardless of VA/Q. The quotient of the first and second images displays the low-VA/Q regions and is corrected for other causes of brightness variation. The technique may provide sufficient quantification of VA/Q to be a useful research tool. The noise in the quotient image is described by the probability density function for the quotient of two normal random variables. When the signal-to-noise ratio of the denominator image is >10, the signal-to-noise ratio of the quotient image is similar to that of the parent images and decreases with pixel value.

Animals↗

Transforming NMR data despite missing points.

Some NMR experiments produce data with several of the initial points missing. The inverse discrete Fourier transform (IDFT) assumes these points are present so the data cannot be so transformed without artifact-ridden results. This problem is often particularly severe when projection imaging with free-induction decays (FIDs). This paper compares recent methods for obtaining a projection from incomplete data and elaborates on their strengths and limitations. One method is to write the transform that would take the desired projection to the truncated data set, and then solve the matrix equation by singular value decomposition. A second replaces the missing data with zeros, so that an IDFT produces a projection with unwanted artifacts. Then one solves the matrix equation that takes the desired projection to the artifact-ridden projection. A third uses the same artifact-ridden projection, but fits the region outside the bandwidth of the sample with as many sinusoidal functions as there are missing data. The coefficients of these functions are estimates of the missing data, and the projection is obtained by transforming the completed FID or subtracting the extrapolation of the fitted curve from the region containing the object. We show that when all three methods are applicable, they theoretically produce the same result. They differ by ease of implementation and possibly by computational errors. They give a result similar to that of the previous method that iteratively corrects the FID and projection after repeated IDFTs and DFTs. We find that one can obtain a projection despite missing a substantial number of data.

Artifacts↗

Effect of head-down tilt on brain water distribution.

Vascular and tissue fluid dynamics in the microgravity of space environments is commonly simulated by head-down tilt (HDT). Previous reports have indicated that intracranial pressure and extracranial vascular pressures increase during acute HDT and may cause cerebral edema. Tissue water changes within the cranium are detectable by T2 magnetic resonance imaging. We obtained T2 images of sagittal slices from five subjects while they were supine and during -13 degrees HDT using a 1.5-Tesla whole-body magnet. The analysis of difference images demonstrated that HDT leads to a 21% reduction of T2 in the subarachnoid cerebrospinal fluid (CSF) compartment and a 11% reduction in the eyes, which implies a reduction of water content; no increase in T2 was observed in other brain regions that have been associated with cerebral edema. These findings suggest that water leaves the CSF and ocular compartments by exudation as a result of increased transmural pressure causing water to leave the cranium via the spinal CSF compartment or the venous circulation.

Adult↗

Efficacy of recombinant human Hb by 31P-NMR during isovolemic total exchange transfusion.

The ability of recombinant human Hb (rHb1.1), which is being developed as an oxygen therapeutic, to support metabolism was measured by in vivo 31P-NMR surface coil spectroscopy of the rat abdomen in control animals and in animals subjected to isovolemic exchange transfusion to hematocrit of <3% with human serum albumin or 5 g/dl rHb1.1. No significant changes in metabolite levels were observed in control animals for up to 6 h. The albumin-exchange experiments, however, resulted in a more than eightfold increase in Pi and a 50% drop in phosphocreatine and ATP within 40 min. The tissue pH dropped from 7.4 to 6.8. The decrease in high-energy phosphates obeyed Michaelis-Menten kinetics, with a Michaelis-Menten constant of 3% as the hematocrit at which a 50% drop in high-energy phosphates was observed. Exchange transfusion with rHb1.1 resulted in no significant drop in high-energy phosphates, no rise in Pi, and no change in tissue pH from 7.35 +/- 0.15 for up to 5 h after exchange. By these criteria, rHb1.1 at a plasma Hb concentration of approximately 5 g/dl after total exchange transfusion was able to sustain energy metabolism of gut tissue at levels indistinguishable from control rats with a threefold higher total Hb level in erythrocytes.

Anesthesia↗

Imaging lungs using inert fluorinated gases.

Rat lungs were imaged by 19F projection MRI of hexafluoroethane, mixed with 20% oxygen to form the inhaled gas. The 3D image had 700 microm resolution, and the data took 4.3 h to acquire. Free induction decays were collected in the presence of steady magnetic field gradients in 686 different directions. To take advantage of fast relaxation (T1 = 5.9 +/- 0.2 ms), the repetition time was 5 ms. To eliminate signal loss from magnetic field inhomogeneities, data were collected within 2 ms of spin excitation (from 80 micros to 2 ms after the 42-micros pi/2 pulses). The singular value decomposition of the transform from frequency to time domain was used to obtain projections despite the absence of data during and immediately after the RF pulses. Inert fluorinated gas imaging may be less expensive than polarized noble gas imaging and is appropriate for imaging steady-state rather than transient gas concentrations.

Animals↗

A programmable pre-emphasis system.

MRI systems often use magnetic field gradient and shim pulse-shaping networks (pre-emphasis) to correct for magnetic field distortions caused by eddy currents. A pre-emphasis system that uses up to 16 fixed resistor-capacitor (RC) time constants per channel with programmable amplitude coefficients is described. The magnetic fields induced by the pre-emphasis RC time constants serve as a set of basis functions for compensating eddy-current fields induced by the gradient set. The resultant time-varying magnetic field gradient accurately reflects the gradient specified by the pulse programmer. Reductions in eddy-current fields are demonstrated for actively shielded and unshielded gradient sets.

Artifacts↗

Diffusion imaging with hyperpolarized 3He Gas

We used MRI of hyperpolarized 3He to demonstrate some novel aspects of gas diffusion. Two different techniques were used. First, a slice was burned into a one-dimensional image by inverting the spins in the slice and diffusion was studied by measuring the magnetization as it filled the depleted slice. A diffusion coefficient was determined by the fit of these data. Second, one-dimensional diffusion images were made using a Stejskal-Tanner PGSE method. This was done with and without a temperature gradient present, showing that the effect of temperature can be dynamically monitored by such diffusion images. Copyright 1997 Academic Press. Copyright 1997Academic Press

Journal Article↗

Changes in muscle proton transverse relaxation times and acidosis during exercise and recovery.

We studied changes in muscle proton (1H) transverse relaxation times (T2) by magnetic resonance imaging during exercise and compared these changes with alterations in muscle metabolism measured by phosphorus-31 magnetic resonance spectroscopy (31P-MRS). Eleven subjects completed two trials of intermittent incremental forearm wrist flexion exercise requiring 30 contractions/min for 5 min, 7 min of recovery between stages, and 5-N load increments/stage. Between stages of the first trial, T2 images of muscle 1H were obtained. Muscle T2 increased from 27.3 +/- 1.1 (SD) ms at rest to 35.8 +/- 3.6 ms after volitional fatigue (P < 0.05), whereas less active wrist extensor muscle T2 remained unchanged (26.8 +/- 0.9 to 28.8 +/- 1.6 ms; P > 0.05). After localizing the predominant muscle recruited from the T2 images, subjects completed an identical trial at least 1 wk later but involving surface coil 31P-MRS of the T2-enhanced muscle to measure the H+ concentration ([H+]). Intramuscular [H+] of T2-enhancing muscle increased from 1.1 +/- 0.1 x 10(-7) M at rest to 4.1 +/- 2.0 x 10(-7) M after volitional fatigue. Both muscle T2 and intramuscular [H+] increased in a bimodal manner, with T2 increasing before muscle [H+] (P < 0.05). The correlation coefficient between the percent change in T2 and muscle [H+] during exercise was +0.74 (range 0.48-0.98; P < 0.05) and +0.47 during recovery. After 12 min of recovery, muscle [H+] decreased to 1.4 +/- 0.3 x 10(-7) M (P < 0.05), and T2 remained close to postexercise values (32.2 +/- 3.1 ms, P > 0.05). The data indicate that 1) the T2 increases during increases in exercise intensity are nonlinear, 2) the T2 increases during exercise are significantly correlated with increases in [H+], and 3) the slow recovery of T2 compared with [H+] indicates that [H+] has a minor contribution to the recovery in T2.

Acidosis↗

A weighted least-squares method for nuclear magnetic resonance velocity imaging.

The phase method for velocity measurements in NMR imaging with more than two velocity encoding steps is discussed. The weighted least-squares method takes into account the variation in the accuracy of phase calculations at a voxel with the size of the velocity encoding gradients. We choose the weights so that the method is equivalent to the method of maximum-likelihood for high signal-to-noise ratios. We propose a method of implementation to minimize the problem of phase wrapping. We also discuss the number of velocity encoding steps, the choice of step size, and signal averaging, to improve the reproducibility of velocity measurements. Standard deviation images for the velocity have been calculated and used to reduce velocity noise by thresholding the velocity image.

Algorithms↗

Alveolar ventilation to perfusion heterogeneity and diffusion impairment in a mathematical model of gas exchange.

This study describes a two-compartment model of pulmonary gas exchange in which alveolar ventilation to perfusion (VA/Q) heterogeneity and impairment of pulmonary diffusing capacity (D) are simultaneously taken into account. The mathematical model uses as input data measurements usually obtained in the lung function laboratory. It consists of two compartments and an anatomical shunt. Each compartment receives fractions of alveolar ventilation and blood flow. Mass balance equations and integration of Fick's law of diffusion are used to compute alveolar and blood O2 and CO2 values compatible with input O2 uptake and CO2 elimination. Two applications are presented. The first is a method to partition O2 and CO2 alveolar-arterial gradients into VA/Q and D components. The technique is evaluated in data of patients with chronic obstructive pulmonary disease (COPD). The second is a theoretical analysis of the effects of blood flow variation in alveolar and blood O2 partial pressures. The results show the importance of simultaneous consideration of D to estimate VA/Q heterogeneity in patients with diffusion impairment. This factor plays an increasing role in gas alveolar-arterial gradients as severity of COPD increases. Association of VA/Q heterogeneity and D may produce an increase of O2 arterial pressure with decreasing QT which would not be observed if only D were considered. We conclude that the presented computer model is a useful tool for description and interpretation of data from COPD patients and for performing theoretical analysis of variables involved in the gas exchange process.

Blood Gas Monitoring, Transcutaneous↗

Velocity imaging of slow coherent flows using stimulated echoes.

We measure the velocity distribution of slow fluid flow in model systems using stimulated echoes and velocity phase encoding. We show velocity images of slow coherent flow with velocities of the order of 0.1 mm/s which is slower than can be obtained by the bolus-tracking method. The eddy current errors were compensated by phase correction.

Humans↗

Human left main coronary artery blood flow: noninvasive Doppler echocardiography with sample volume tracking.

We developed sample volume tracking units that controlled the pulsed ultrasonic Doppler sample volume location in relation with the anterior-posterior movement of the human left main coronary artery (LMCA). Combined with noninvasive Doppler echocardiographic mechanical sector scanners (DS), the trackers controlled the axial location of the sample volume by range gate control. The Doppler angle was minimized with the long axis of the imaged LMCA. Both stored waveform, memory-driven (MD) and real-time (RT) trackers were developed. These devices were used to measure blood velocity spectral waveforms and lumen diameters, which were used to calculate flow. Using the RT tracker, we compared DS measurements with known flows (0-1000 ml/min) in a moving 4 mm tygon tubing phantom (r = 0.92, SEE = 32 ml/min). Using the MD tracker, we compared the DS with simultaneous invasive flow measurements in 11 patients with angiographically normal coronaries and ventricular function during cardiac catheterization. Using the RT tracker, we compared the DS measurements with subsequent nonsimultaneous, invasive flow data in 8 similar patients. Invasively determined flows were calculated from angiographic diameters and blood velocities which were obtained with a Doppler velocimeter catheter. Regression coefficients (r) were: (Table: see text). V = maximum velocity, D = diameter, Q = mean flow, *p less than .05 Interoperator and intraoperator variabilities in vivo of DS measurements with RT tracking were 21% and 15%, respectively. We conclude that Doppler echocardiography with either MD or RT sample volume tracking may be of limited clinical usefulness in the noninvasive measurement of phasic left main coronary artery blood flow in unselected patients.

Angiocardiography↗

Rapid average-flow velocity measurement by NMR.

We describe an NMR method to make a quick determination of average fluid velocity by monitoring the change in phase of the magnetization during a transient signal. We give an example utilizing the second Carr-Purcell-Meiboom-Gill echo in which we measured the velocity of water up to 54 cm/s where each velocity was determined by data taken over 2.5 ms.

Humans↗