Search PubMedSearch

subject

Image-Guided Biopsy

Image-Guided Biopsy: explore 3 source-linked works published from 2026 to 2026, with original documents and citations.

This collection is a preview while coverage and quality are evaluated.

Search within this collection

Coverage and selection

Includes records with this source-supplied label or an explicit phrase match in their metadata. Matches indicate a mention, not proof that a paper uses a method or tests a material. Source versions are consolidated by DOI.

Sources: pubmed. Collection updated 2026-09-15. Counts describe this index, not the complete source archives.

PCa Detection in PI-RADS 4 and 5 Lesions: Comparison of [68Ga]Ga-PSMA-11 PET/CT-Guided Robot-Assisted Biopsy Versus mpMRI Cognitive-Fusion TRUS-Guided Prostate Biopsy.

Lesions with a Prostate Imaging-Reporting and Data System (PI-RADS) score of 4 or greater on multiparametric MRI (mpMRI) indicate a high likelihood of prostate cancer (PCa), and guidelines recommend a targeted biopsy. We aimed to compare the diagnostic performance of robotic arm-assisted [68Ga]Ga-PSMA-11 PET/CT-guided prostate biopsy (PGPB) with mpMRI-directed cognitive-fusion transrectal ultrasound-guided biopsy (MCFB) in biopsy-na&#xef;ve men with clinical findings suggestive of PCa. Methods: This prospective, single-center, randomized clinical trial (NCT05137561) enrolled biopsy-na&#xef;ve men age 50-90 y with elevated levels of prostate-specific antigen (&#x2265;4 ng/mL) and abnormal digital rectal examination findings. All participants underwent mpMRI, and those with a PI-RADS score of 4 or greater were randomized into 2 arms. In arm 1, participants underwent PGPB for a [68Ga]Ga-PSMA-avid lesion, and participants in arm 2 underwent MCFB. Participants in arm 1 with PET-negative findings subsequently underwent MCFB, and participants with negative biopsy results underwent PET and PGPB. The primary outcome was the detection of PCa. Secondary outcomes included complication rates and participant-reported pain. Result: Of the 267 participants enrolled, 81.3% (217) had lesions with a PI-RADS score of 4 or greater and were randomized to either PGPB (n = 112) or MCFB (n = 105). PCa was detected in 97.1% of participants (101/104) in arm 1 and 81.0% (85/105) in arm 2 (P < 0.05). PGPB showed higher diagnostic accuracy for PI-RADS 5 lesions (100% vs. 95.1%, P = 0.09). Major complications were observed in arm 2 only (n = 5). Arm 1 had significantly fewer complications (10.8% vs. 51.4%, P < 0.01), a lower median visual analog scale score for pain (3 vs. 5), and shorter procedure times. The core positivity rate was higher in arm 1 (60% &#xb1; 20%), despite obtaining fewer cores. Conclusion: [68Ga]Ga-PSMA-11 PGPB demonstrated higher diagnostic performance, fewer complications, and better tolerability compared with MCFB. This approach enables integrated diagnosis and staging, offering a promising alternative for efficient, safe, and accurate evaluation of prostate cancer.

Humans

Complication rates of 16- and 18-gauge needles for native kidney biopsies: a systematic review and proportional meta-analysis.

This systematic review and meta-analysis evaluated complication rates and diagnostic yield reported in studies of adult native kidney biopsy using 16-gauge (16&#x2009;G) or 18-gauge (18&#x2009;G) needles. We included randomized trials and cohort studies of real-time ultrasound-guided biopsies, including case series. MEDLINE, Embase, and CENTRAL were searched through October 2024. Two reviewers independently performed study selection, data extraction, and risk of bias assessment using Joanna Briggs Institute tools. Random-effects meta-analyses estimated pooled proportions with 95% confidence intervals (CI), and univariable random-effects meta-regression explored study-level associations with major complications, transfusion, or gross hematuria. We screened 4,499 titles and abstracts and reviewed 319 full-text articles; 62 studies comprising 68 biopsy series were included. The pooled major complication rate in studies using 16&#x2009;G needles was 1.83% (95% CI: 1.20-2.79) and 1.29% (95% CI: 0.78-2.13) in studies using 18&#x2009;G needles, with no statistically significant difference. Mean glomerular yield was 18.8 with 16&#x2009;G and 17.5 with 18&#x2009;G needles. In study-level meta-regression, studies with higher prevalence of acute kidney injury, lower mean estimated glomerular filtration rate, or lower mean hemoglobin reported higher pooled complication rates. Most studies were single-arm cohorts; between-needle differences therefore reflect indirect study-level contrasts. Interpretation is limited by retrospective design and heterogeneity across studies. Overall, studies using both needle sizes reported low complication rates and similar diagnostic yield, although definitions and reporting varied. Direct comparative studies are needed to determine whether meaningful differences exist.

Humans

Robotic Needle Insertion for CT-guided Percutaneous Biopsy of Thoracoabdominal Lesions: A Prospective Multicenter Randomized Trial.

Purpose To compare safety and feasibility between a novel CT-guided robotic system and the conventional freehand technique for puncture biopsy of thoracoabdominal lesions. Materials and Methods In this prospective multicenter randomized trial, individuals with suspected lesions were enrolled between July 2023 and April 2024 across three university teaching hospitals and randomized to the robot-assisted group (n = 82) or the freehand group (n = 83). Procedure outcomes included the technical success rate, targeting error, number of CT scans and needle adjustments, puncture time, and complications. Descriptive and inferential statistics were calculated. Results A total of 165 participants (mean age, 60 years &#xb1; 10 [SD]; 83 male) were included. Compared with the freehand group, the robot-assisted group demonstrated a higher technical success rate (97.56% [80 of 82] vs 62.65% [52 of 83], P < .001), lower targeting error (mean Euclidean deviation: 1.7 mm &#xb1; 1.1 vs 4.5 mm &#xb1; 3.9, P < .001), and fewer CT scans (mean, 4.3 &#xb1; 1.9 vs 5.2 &#xb1; 2.3; P = .002) and needle adjustments (mean, 0.7 &#xb1; 0.7 vs 1.6 &#xb1; 1.6; P = .003). Despite differences in geometric precision, both groups achieved 100% (82 of 82 and 83 of 83) diagnostic yield. The median puncture time was comparable between groups (5.5 minutes &#xb1; 4.3 vs 4.8 minutes &#xb1; 7.0, P = .50). During lung biopsies, the robot-assisted approach yielded fewer complications compared with the freehand approach (4.88% [four of 82] vs 16.87% [14 of 83], P = .014). Conclusion Compared with the freehand approach, robot-assisted biopsy yielded greater precision and reduced adjustments and complications while demonstrating noninferior diagnostic efficacy and comparable duration. Keywords: Robotic Needle Insertion, Biopsy, Thoracoabdominal Lesions, Robot-assisted Biopsy, CT-guided Intervention, Percutaneous Needle Biopsy, Randomized Controlled Trial, Algorithm Development, CT, Clinical Testing, Interventional-Body, Biopsy/Needle Aspiration, Percutaneous, Thorax, Abdomen/GI, Liver, Lung, Kidney &#xa9;RSNA, 2026.

Humans
Compare source metadata on this page

These are bibliographic comparisons, not experimental rankings. Follow the original document for methods and conditions.