Search PubMedSearch

subject

kidney biopsy

kidney biopsy: explore 1 source-linked works published from 2026 to 2026, with original documents and citations.

This collection is a preview while coverage and quality are evaluated.

Search within this collection

Coverage and selection

Includes records with this source-supplied label or an explicit phrase match in their metadata. Matches indicate a mention, not proof that a paper uses a method or tests a material. Source versions are consolidated by DOI.

Sources: pubmed. Collection updated 2026-09-15. Counts describe this index, not the complete source archives.

Complication rates of 16- and 18-gauge needles for native kidney biopsies: a systematic review and proportional meta-analysis.

This systematic review and meta-analysis evaluated complication rates and diagnostic yield reported in studies of adult native kidney biopsy using 16-gauge (16 G) or 18-gauge (18 G) needles. We included randomized trials and cohort studies of real-time ultrasound-guided biopsies, including case series. MEDLINE, Embase, and CENTRAL were searched through October 2024. Two reviewers independently performed study selection, data extraction, and risk of bias assessment using Joanna Briggs Institute tools. Random-effects meta-analyses estimated pooled proportions with 95% confidence intervals (CI), and univariable random-effects meta-regression explored study-level associations with major complications, transfusion, or gross hematuria. We screened 4,499 titles and abstracts and reviewed 319 full-text articles; 62 studies comprising 68 biopsy series were included. The pooled major complication rate in studies using 16 G needles was 1.83% (95% CI: 1.20-2.79) and 1.29% (95% CI: 0.78-2.13) in studies using 18 G needles, with no statistically significant difference. Mean glomerular yield was 18.8 with 16 G and 17.5 with 18 G needles. In study-level meta-regression, studies with higher prevalence of acute kidney injury, lower mean estimated glomerular filtration rate, or lower mean hemoglobin reported higher pooled complication rates. Most studies were single-arm cohorts; between-needle differences therefore reflect indirect study-level contrasts. Interpretation is limited by retrospective design and heterogeneity across studies. Overall, studies using both needle sizes reported low complication rates and similar diagnostic yield, although definitions and reporting varied. Direct comparative studies are needed to determine whether meaningful differences exist.

Humans
Compare source metadata on this page

These are bibliographic comparisons, not experimental rankings. Follow the original document for methods and conditions.