Search PubMed⌕ Search

PubMed · 16282649

Electroactive fabrics for distributed, comfortable and interactive systems.

Abstract

Monitoring body kinematics has fundamental relevance in several biological and technical disciplines. In particular the possibility to know the posture exactly may furnish a main aid in rehabilitation topics. In the present work a collection of innovative and unobtrusive garments able to detect the posture and the movement of the human body are introduced. This paper deals with the design, the development and the realization of sensing garments, from the characterization of innovative comfortable and spreadable sensors to the methodologies employed to gather information on the posture and movement. Several new algorithms devoted to the device operation are presented and tested. Data derived from the sensing garment are analyzed and compared with the data derived from a traditional movement tracking system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Federico Lorussi, Alessandro Tognetti, Mario Tesconi, Giuseppe Zupone, Raphael Bartalesi, Danilo De Rossi. 2005. Electroactive fabrics for distributed, comfortable and interactive systems.. https://pubmed.ncbi.nlm.nih.gov/16282649/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Ultrasonic model and system for measurement of corneal biomechanical properties and validation on phantoms.

Non-invasive measurement of biomechanical properties of corneas may provide important information for ocular disease management and therapeutic procedures. An ultrasonic non-destructive evaluation method with a wave propagation model was developed to determine corneal biomechanical properties in vivo. In this study, we tested the feasibility of the approach in differentiating the mechanical properties of soft contact lenses as corneal phantoms. Three material types of soft contact lenses (six samples in each group) were measured using a broadband ultrasound transducer. The ultrasonic reflections from the contact lenses were recorded by a 500MHz/8-bit digitizer, and displayed and processed by a PC. A reference signal was recorded to compute the normalized power spectra using Fast Fourier Transformation. An inverse algorithm based on least-squares minimization was used to reconstruct three parameters of the contact lenses: density, thickness, and elastic constants lambda+2micro. The thickness of each sample was verified using an electronic thickness gauge, and the averaged density for each type of lenses was verified using Archimedes' principle and manufacturer's report. Our results demonstrated that the ultrasonic system was able to differentiate the elastic properties of the three types of the soft contact lenses with statistical significance (P-value<0.001). The reconstructed thicknesses and densities agreed well with the independent measurements. Our studies on corneal phantoms indicated that the ultrasonic system was sensitive and accurate in measuring the material properties of cornea-like structures. It is important to optimize the system for in vivo measurements.

Biomechanical Phenomena↗

Orientation feedback during simulated simple translation tests has little clinical significance on the magnitude and precision of glenohumeral joint translations.

The repeatability of shoulder instability clinical examinations has been reported to be poor, producing a large range of translations. The objective of this study was to determine the effect of providing the clinician with joint orientation feedback on the magnitude and precision of glenohumeral joint kinematics. A 6-degree of freedom magnetic tracking system was used to determine the kinematics of the humerus with respect to the scapula (n=8 cadaveric shoulders). The joints were preconditioned with simple loading tests five times. At 60 degrees of glenohumeral abduction and 0 degrees of flexion/extension, a clinician then applied an anterior and posterior load to the humerus until a manual maximum simulating a simple translation test (STT) was achieved at 0, 30, and 60 degrees of external rotation with and without angular orientation feedback of the humerus with respect to the scapula. The precision for the external rotation was within 4.3 degrees for the feedback group and 17.5 degrees for the no feedback group over all external rotations. For achieving the target external rotation of 30 degrees , there was a significant difference in precision between the feedback and no feedback groups (p<0.05). The magnitudes of the anterior translations were 18.2+/-5.3, 15.5+/-5.1, and 9.9+/-5.5 mm for the feedback group and 19.3+/-6.6, 17.5+/-4.9, and 11.5+/-5.3 mm for the no feedback group, at 0, 30, and 60 degrees of external rotation, respectively. There was a significant difference in the precision of anterior translation at 30 and 60 degrees of external rotation for 4 of 8 specimens (p<0.05). Significant differences in the precision of the posterior translation was only detected at 0 degrees of external rotation for 3 of 8 specimens (p<0.05). Based on the data obtained, providing orientation feedback to a clinician performing a simulated STT results in increased precision for not only the target external rotations but also the resulting glenohumeral translations. While providing feedback may be a necessary step to achieving precise results for experimental studies, the magnitudes of translations in the anterior and posterior directions were relatively similar for the feedback and no feedback states indicating little benefit for clinical examinations.

Biomechanical Phenomena↗

Reflection makes sense of rotation of the eyes.

Our 3-D percept of the world is constructed from the two-dimensional visual images on the retina of each eye, but these images and the relationships between them are affected by the 3-D rotations of each eye. These 3-D eye rotations are constrained to patterns such as Listing's law, or its generalisation 'L2', according to the context. Our understanding of the patterns of such three-dimensional eye rotations, and their effect on the retinal images, has been greatly advanced by the development of algebraic methods (Haustein, 1989; Tweed & Vilis, 1987; Westheimer, 1957) for calculating the effect of eye rotations. But not many would say, with Dirac, that they understand the equations describing the 3-D geometry in the sense that they have "a way of figuring out the characteristic of its solution without actually solving it" (Dirac, according to Feynman, Leighton, & Sands, 1964). I show here how the geometry of 3-D rotations of the eye and their visual effects can be made easier to understand by use of the principle that a rotation through angle alpha can be achieved by a pair of reflections in planes with an angular separation alpha/2, and a common line that is the rotation axis (Tweed, 1997b; Tweed, Cadera, & Vilis, 1990). Mathematically (see Appendix A), the method is equivalent to decomposing the unit quaternions so successfully used to study three-dimensional eye rotations (Tweed & Vilis, 1987; Westheimer, 1957) into pairs of pure quaternions (ones whose scalar part is zero) which represent the reflections (Coxeter, 1946).

Biomechanical Phenomena↗