Abstract

The advantage of using a proximal ingrowth hip revision component is restoring physiologic load to the revision femur. Although first generation components had limited survivorship and diminished clinical outcomes, subsequent designs have proven much better with rates of aseptic loosening of 2% to 5%, and good clinical scores. Titanium is the favored substrate metal for these components because of its bone affinity and low modulus of elasticity. A series of 107 consecutive revisions of standard stems is presented using a calcar replacement long stem design with an overall 92.7% 11-year survivorship. Bone ingrowth was achieved in all but two components. Radiographic stress shielding was seen in 11.4% with 42.6% having some calcar healing. These implants can be used in most revision situations, but require sufficient proximal metaphysis of the femur to provide support of the component. Supplemental allograft may need to be used. These implants require a tight fit in the isthmus of the femur and fill of the proximal femur. Modularity makes achieving this easier, but monoblock designs also can be successful.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Roger H Emerson. 2004. Proximal ingrowth components.. https://doi.org/10.1097/00003086-200403000-00018

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

In vivo behavior of acrylic bone cement in total hip arthroplasty.

Polymethylmethacrylate (PMMA) bone cement serves as the primary fixation material between bone and the prosthetic component in cemented total hip arthroplasty. In vivo degradation of bone cement may lead to a decrease in mechanical properties of PMMA and result in aseptic loosening. However, other factors such as porosity and location of the cement relative to the bone implant interface may also contribute to mechanical behavior in vivo. This study investigated the mechanical properties of Simplex cement retrieved from 43 patients undergoing revision total hip arthroplasty. The time in vivo was between 1 month and 27 years. The variables studied included fracture toughness (KIC), porosity, molecular weight, time in vivo of the cement, and relative in vivo location of the cement with respect to the implant and bone. KIC did not correlate with time in vivo of the samples or with molecular weight. This suggests that time in vivo may not be the limiting factor in the mechanical integrity of the bone cement, A significant and inverse relationship was found between porosity and KIC. This implies that porosity is the most important factor in the mechanical behavior of bone cement during in vivo use.

Arthroplasty, Replacement, Hip↗

Three-dimensional computer-aided design based design sensitivity analysis and shape optimization of the stem using adaptive p-method.

The number of stem designs for total hip arthroplasty is increasing, and occasionally design changes have yielded unexpected clinical results. At present, we are not able to clearly identify which parameter of the stem is most important, and the optimum value of many parameters. The goals of this study were to identify which parameter is most important, to understand the effect of design change, and to find the optimum stem shape. For this purpose, we used adaptive p-method together with three-dimensional computer-aided design software program for the design sensitivity analysis (DSA) and shape optimization of the stem. The results suggested that increasing the lateral and medial width of the distal cross-section together with decreasing the medial-lateral width and the medial radius of the distal cross-section from the default value would lead to a decrease in the largest maximum principal stress of the distal cement. The medial width of middle cross-section, however, was not so simple. The result of DSA suggested that decreasing this parameter from the default value decreased the stress in the distal cement, but the optimum shape was obtained by increasing this parameter. The method used in this study will assist our engineers and surgeons in the process of modifying and optimizing the stem design.

Arthroplasty, Replacement, Hip↗