Three-dimensional computer-aided design based design sensitivity analysis and shape optimization of the stem using adaptive p-method.

Abstract

The number of stem designs for total hip arthroplasty is increasing, and occasionally design changes have yielded unexpected clinical results. At present, we are not able to clearly identify which parameter of the stem is most important, and the optimum value of many parameters. The goals of this study were to identify which parameter is most important, to understand the effect of design change, and to find the optimum stem shape. For this purpose, we used adaptive p-method together with three-dimensional computer-aided design software program for the design sensitivity analysis (DSA) and shape optimization of the stem. The results suggested that increasing the lateral and medial width of the distal cross-section together with decreasing the medial-lateral width and the medial radius of the distal cross-section from the default value would lead to a decrease in the largest maximum principal stress of the distal cement. The medial width of middle cross-section, however, was not so simple. The result of DSA suggested that decreasing this parameter from the default value decreased the stress in the distal cement, but the optimum shape was obtained by increasing this parameter. The method used in this study will assist our engineers and surgeons in the process of modifying and optimizing the stem design.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Tanino, H Ito, M Higa, N Omizu, I Nishimura, K Matsuda, Y Mitamura, T Matsuno. 2005-07-18. Three-dimensional computer-aided design based design sensitivity analysis and shape optimization of the stem using adaptive p-method.. https://doi.org/10.1016/j.jbiomech.2005.05.024

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

In vivo behavior of acrylic bone cement in total hip arthroplasty.

Polymethylmethacrylate (PMMA) bone cement serves as the primary fixation material between bone and the prosthetic component in cemented total hip arthroplasty. In vivo degradation of bone cement may lead to a decrease in mechanical properties of PMMA and result in aseptic loosening. However, other factors such as porosity and location of the cement relative to the bone implant interface may also contribute to mechanical behavior in vivo. This study investigated the mechanical properties of Simplex cement retrieved from 43 patients undergoing revision total hip arthroplasty. The time in vivo was between 1 month and 27 years. The variables studied included fracture toughness (KIC), porosity, molecular weight, time in vivo of the cement, and relative in vivo location of the cement with respect to the implant and bone. KIC did not correlate with time in vivo of the samples or with molecular weight. This suggests that time in vivo may not be the limiting factor in the mechanical integrity of the bone cement, A significant and inverse relationship was found between porosity and KIC. This implies that porosity is the most important factor in the mechanical behavior of bone cement during in vivo use.

Arthroplasty, Replacement, Hip↗

A comparison of the shrinkage of commercial bone cements when mixed under vacuum.

The outcome of a cemented hip arthroplasty is partly dependent on the type of cement which is used. The production of an interface gap between the stem and the cement mantle as a result of shrinkage of the cement, may be a factor involved. Palacos R, Palacos LV (both with gentamicin), CMW 1, CMW 2, CMW Endurance (CMWE) and Simplex were prepared under vacuum and allowed to cure overnight in similar cylinders. The next day this volume was determined by the displacement of water. Shrinkage varied between 3.82% and 7.08% with CMWE having the lowest and Palacos LV the highest. This could be a factor to consider when choosing a cement for a shape-closed stem.

Arthroplasty, Replacement, Hip↗

CT analysis of defects of the cement mantle and alignment of the stem: in vitro comparison of Charnley-Kerboul femoral hip implants inserted line-to-line and undersized in paired femora.

Using a modern cementing technique, we implanted 22 stereolithographic polymeric replicas of the Charnley-Kerboul stem in 11 pairs of human cadaver femora. On one side, the replicas were cemented line-to-line with the largest broach. On the other, one-size undersized replicas were used (radial difference, 0.89 mm sd 0.13).CT analysis showed that the line-to-line stems without distal centralisers were at least as well aligned and centered as undersized stems with a centraliser, but were surrounded by less cement and presented more areas of thin (< 2 mm) or deficient (< 1 mm) cement. These areas were located predominantly at the corners and in the middle and distal thirds of the stem. Nevertheless, in line-to-line stems, penetration of cement into cancellous bone resulted in a mean thickness of cement of 3.1 mm (sd 0.6) and only 6.2% of deficient and 26.4% of thin cement. In over 90% of these areas, the cement was directly supported by cortical bone or cortical bone with less than 1 mm of cancellous bone interposed. When Charnley-Kerboul stems are cemented line-to-line, good clinical results are observed because cement-deficient areas are limited and are frequently supported by cortical bone.

Arthroplasty, Replacement, Hip↗