Search PubMedSearch

SEARCH · Search PubMed

Results for “screw placement accuracy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

166 recordsLinked to original sources

Safety and Stability of a Combined C2 Screw Placement Strategy With Vertebral Artery Mobilization.

BACKGROUND: Although C2 pedicle screws are considered the gold standard for atlantoaxial fixation, the optimal fixation strategy for patients with high-riding vertebral arteries (HRVA) or narrow C2 pedicles (NC2P) remains controversial because of the increased risk of vertebral artery injury and the limitations of alternative fixation techniques. OBJECTIVE: To evaluate the safety, stability, and clinical efficacy of an individualized C2 screw fixation strategy incorporating vertebral artery mobilization for complex upper cervical anatomy. METHODS: A retrospective study was conducted in 312 patients who underwent C2 fixation between 2017 and 2025. Patients were categorized according to fusion method, screw laterality, and VA transposition requirement. Bone fusion rates and screw accuracy (Gertzbein-Robbins grading) were compared across groups using &#x3c7;2, Fisher's exact, and multivariate logistic regression analyses to control confounders. RESULTS: All procedures were successfully completed without permanent neurovascular injury. At 6&#x2009;months, the fusion rate with an atlantoaxial fusion cage was significantly higher than with interlaminar bone grafting (92.3% vs. 51.0%, p&#x2009;<&#x2009;0.001). Unilateral C2 pedicle screw fixation combined with a contralateral alternative screw achieved comparable stability to bilateral fixation (p&#x2009;>&#x2009;0.05). Screw placement accuracy was 100% clinically acceptable in normal anatomy and 60% in cases requiring VA mobilization, with no VA injury or blood flow compromise. CONCLUSION: The proposed multi-strategy C2 screw placement protocol-integrating fusion cage support and VA mobilization-achieves superior fusion, reliable fixation, and high safety, even in anatomically challenging conditions. This approach provides a reproducible and versatile solution for C2 instrumentation in complex craniovertebral junction surgery.

Humans

Robot-assisted versus freehand cannulated-screw fixation for femoral neck fractures: a systematic review of technical, clinical and adoption outcomes.

Robot-assisted guidance may improve the technical precision of percutaneous cannulated-screw fixation for femoral neck fractures. Whether these procedural advantages translate into better clinical outcomes remains uncertain. We compared robot-assisted and conventional freehand fixation in adults with femoral neck fractures. MEDLINE, Embase and CINAHL were searched from inception to 15 July 2026 without language restrictions. Google Scholar was used only as a supplementary search source, together with forward and backward citation searching. Comparative studies of robot-assisted versus freehand fluoroscopy-guided cannulated-screw fixation were included. Risk of bias was assessed using RoB 2 and ROBINS-I, with the Newcastle-Ottawa Scale used as a complementary appraisal of non-randomised studies. Random-effects meta-analyses included prediction intervals and prespecified sensitivity analyses. The protocol was registered prospectively (PROSPERO CRD420261465038). Sixteen comparative studies involving 1,293 participants were included. Of these, 597 underwent robot-assisted fixation and 696 underwent freehand fixation. Two studies reporting random allocation and 14 non-randomised studies were included in the study. Robot-assisted fixation was associated with fewer guide-wire manipulations, greater screw-placement accuracy and 13.9 fewer fluoroscopic acquisitions per procedure (95% confidence interval [CI] -20.3 to -7.5). Earlier radiographic healing and modestly higher final Harris Hip Scores were also observed. Pooled estimates suggested lower risks of union failure, avascular necrosis and composite complications. Fluoroscopy duration, overall operative time and reoperation did not differ significantly. Heterogeneity was substantial for several continuous outcomes, with prediction intervals crossing the null for several estimates, indicating that the magnitude of benefit varied considerably between studies. Some clinical associations were also sensitive to eligibility-restricted analyses. Robot-assisted cannulated-screw fixation improves technical execution compared with freehand fixation. Patient-important clinical superiority and economic value have not been established, and evidence concerning learning curves, operator acceptability and system reliability remains insufficient. Current evidence does not support routine widespread adoption; adequately powered multicentre randomised trials incorporating economic and implementation evaluation are required.

Humans

Application of Three-Dimensionally Printed Surgical Guides in Precise Sacral Tumor Excision and Defect Reconstruction.

OBJECTIVE: Precise resection of sacral tumors remains technically demanding due to their deep anatomical location and close proximity to critical neurovascular structures. Conventional freehand techniques often result in suboptimal resection margins, excessive blood loss, and compromised lumbopelvic stability. This study evaluated whether patient-specific three-dimensional (3D)-printed guiding templates improve surgical accuracy and perioperative outcomes in sacral tumor resection and reconstruction. METHODS: Nineteen patients undergoing en bloc sacral tumor resection (S1-S3 involvement) with spinopelvic reconstruction (2006-2020) were retrospectively analyzed. Patients were divided into a 3D-printing group (n&#x2009;=&#x2009;10) and a conventional freehand group (n&#x2009;=&#x2009;9). In the 3D-printing group, computer-aided design and 3D-printed templates were used for osteotomy, screw placement, and defect reconstruction. Perioperative metrics, surgical accuracy, and complications were compared between groups using Welch's t-test and the Hodges-Lehmann method; oncologic events during follow-up were recorded descriptively. RESULTS: The 3D-printing group demonstrated significantly shorter operative time (456.5&#x2009;&#xb1;&#x2009;62.36 vs. 574.44&#x2009;&#xb1;&#x2009;114.58&#x2009;min, p&#x2009;=&#x2009;0.012), reduced blood loss (4081.40&#x2009;&#xb1;&#x2009;838.99 vs. 5090.0&#x2009;&#xb1;&#x2009;1059.67&#x2009;mL, p&#x2009;=&#x2009;0.034), and fewer fluoroscopic exposures (4.2&#x2009;&#xb1;&#x2009;0.79 vs. 10.0&#x2009;&#xb1;&#x2009;1.58, p&#x2009;<&#x2009;0.001) compared with the conventional group. Osteotomy accuracy was also superior in the 3D-printing group, with significantly lower angular deviation (3.33&#xb0;&#x2009;&#xb1;&#x2009;0.45&#xb0; vs. 6.79&#xb0;&#x2009;&#xb1;&#x2009;2.16&#xb0;, p&#x2009;=&#x2009;0.0012). Postoperative complication rates were comparable (30% vs. 44.4%, p&#x2009;=&#x2009;0.649), but hospital stay was significantly shorter in the 3D-printing group (10.7&#x2009;&#xb1;&#x2009;2.71 vs. 18.11&#x2009;&#xb1;&#x2009;4.01&#x2009;days, p&#x2009;<&#x2009;0.001). CONCLUSION: Patient-specific 3D-printed guiding templates enhance precision in sacral tumor excision and reconstruction, improving surgical efficiency and perioperative safety. This computer-assisted, template-guided approach represents a valuable advancement for complex sacral oncologic surgery.

Humans

K-wire versus screw fixation in Scarf-Akin osteotomy for hallux valgus: A retrospective cohort study.

BACKGROUND: Retention of metal implants after Scarf-Akin osteotomy (SAO) may cause irritation and psychological discomfort, often necessitating a hardware removal procedure. This study aimed to introduce K-wire fixation, allowing for outpatient removal, and to compare it with screw fixation. METHODS: This retrospective study included 64 patients with hallux valgus, comprising 32 in the K-wire fixation group and 32 in the screw fixation group. Clinical outcomes were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) score, visual analogue scale (VAS), and patient satisfaction. Radiographic parameters included hallux valgus angle(HVA), intermetatarsal angle(IMA), and distal metatarsal articular angle(DMAA). RESULTS: Both groups showed significant clinical and radiographic improvement (P&#x202f;<&#x202f;0.01). No significant between-group differences were observed in the other clinical or radiographic outcomes (P&#x202f;>&#x202f;0.05). Treatment costs were significantly lower in the K-wire group (P&#x202f;<&#x202f;0.001). CONCLUSIONS: K-wire fixation provides clinical and radiographic outcomes comparable to screw fixation, while avoiding the need for an additional procedure to remove the implant. LEVEL OF EVIDENCE: Level III.

Humans

Comparative efficacy of percutaneous vertebroplasty combined with minimally invasive pedicle screw fixation versus percutaneous vertebroplasty alone in the treatment of elderly osteoporotic vertebral compression fractures.

The study aimed to assess the comparative efficacy of percutaneous vertebroplasty (PVP) combined with minimally invasive pedicle screw fixation versus PVP alone in elderly patients with osteoporotic vertebral compression fractures (OVCF). Ninety-four elderly patients with OVCF were randomly classified into the control (47 patients) and combined (47 patients) groups. The control group received PVP, while the combined group received PVP combined with minimally invasive pedicle screw fixation. Perioperative indicators such as intraoperative blood lose, operative time, and hospitalization time were recorded. Pain was assessed using the VAS before and at baseline and 1, 3, and 7 days postoperatively. At 1 and 3 days postoperatively, Serum CRP levels, WBC, and neutrophil counts were measured postoperatively. Radiographic outcomes (vertebral height ratio and Cobb angle), ADL scores, JOA scores, and ODI were evaluated preoperatively and at 3 months post-operation. Postoperative complications were documented. Baseline characteristics were comparable. The combined group showed superior pain relief, vertebral height restoration, Cobb angle correction, functional recovery, and reduced inflammatory markers (CRP, WBC, neutrophils) postoperatively (all P&#x2009;<&#x2009;0.05). Blood loss and hospital stay were shorter in the combined group, though operative time was longer (P&#x2009;<&#x2009;0.05). Complication rates did not differ significantly (P&#x2009;>&#x2009;0.05). PVP combined with minimally invasive pedicle screw fixation yields better outcomes in elderly OVCF patients by enhancing pain control, vertebral height, and functional recovery without increasing perioperative risk.

Humans

Bioabsorbable vs. titanium screws in first metatarsophalangeal joint arthrodesis: a pilot randomized controlled trial with 2-year follow-up.

INTRODUCTION: To assess the feasibility and preliminary clinical outcomes of bioabsorbable screw fixation in first metatarsophalangeal joint arthrodesis compared to conventional titanium screw fixation. METHODS: In this prospective pilot randomized controlled trial, 30 patients were allocated 1:1 to bioabsorbable or titanium cannulated lag screw fixation. Arthrodesis was performed using a cup-and-cone technique at two Finnish hospitals. Full weight-bearing in an orthopaedic shoe was allowed after six weeks. Outcomes included AOFAS and VA-FAS FA-VAS scores, union rates, and complications assessed at 3, 6, 12, and 24 months. RESULTS: Both groups showed significant functional improvement with no between-group differences. At 24 months, mean AOFAS scores were 89.1 (SD 2.7) in the titanium group and 90.0 (SD 0.0) in the bioabsorbable group (p = 0.23). Mean FA-VAS total scores (sum of pain, function, and complaints subscales) were 1948 (SE 59.4) in the titanium group and 1914 (SE 61.4) in the bioabsorbable group (p = 0.655). Union rate was 90% overall; nonunion occurred in one titanium and two bioabsorbable patients, all requiring revision. No implant-related complications or hardware removal surgeries were recorded. Degradation of bioabsorbable screws caused no adverse clinical or radiographic reactions. CONCLUSIONS: Bioabsorbable screws appear safe and feasible in first metatarsophalangeal joint arthrodesis, with preliminary outcomes comparable to titanium fixation. These findings support the conduct of a larger confirmatory trial. TRIAL REGISTRATION: ClinicalTrials.gov, NCT03133039, registered 28 April 2017. https://clinicaltrials.gov/ct2/show/NCT03133039.

Humans

Oblique Lateral Interbody Fusion With Lateral Vertebral Screw Fixation Versus Transforaminal Lumbar Interbody Fusion for Severe Lumbar Stenosis: Results of a Multicenter Randomized Controlled Trial.

BACKGROUND AND OBJECTIVES: The benefits of oblique lateral interbody fusion (OLIF) vs transforaminal lumbar interbody fusion (TLIF) in severe lumbar stenosis (Schizas C/D) remain uncertain. This randomized trial compared clinical, radiographic, and safety outcomes of OLIF and TLIF. METHODS: From November 2018 to December 2021, a prospective, multicenter, randomized controlled trial enrolled 260 adults with single-level severe stenosis and instability. In total, 224 patients were randomized to OLIF or TLIF. Prespecified outcomes followed consolidated standards of reporting trials. Primary outcomes were visual analog scale back/leg pain and Oswestry Disability Index (ODI), with minimal clinically important difference thresholds of ODI &#x2265;12-13 points or &#x2265;30% improvement, and visual analog scale &#x2265;1.5-2.0 points. Radiographic measures included disc height, lumbar and segmental lordosis, and canal cross-sectional area (CSA). Complications were recorded. Ethics approval was obtained from the institutional review board, the trial was registered with ISRCTN.com , and all patients provided written informed consent. RESULTS: In total, 224 patients were randomized, 5 were lost to follow-up (TLIF n = 2, OLIF n = 3). Baseline features were comparable. OLIF was associated with shorter operative time, less blood loss, earlier ambulation, and shorter hospital stay (all P < .05). Both groups achieved significant, clinically meaningful improvements. OLIF showed greater back pain reduction at 3-6 months and 2 years ( P < .05) and superior ODI improvement at 3 and 6 months ( P < .001), although long-term ODI scores were similar. Radiographically, OLIF provided greater restoration of disc height and segmental lordosis (all P < .001) and demonstrated progressive CSA increase (dynamic decompression), whereas TLIF achieved immediate, sustained CSA enlargement. Fusion rates were comparable at 1-2 years. Complication rates were low and similar (7.3% TLIF vs 5.5% OLIF), with most OLIF-specific events transient. CONCLUSION: Both OLIF and TLIF yield improvements in severe lumbar stenosis. OLIF offers perioperative advantages, earlier functional recovery, radiographic restoration, and dynamic canal remodeling, supporting its role as an equivalent alternative for lumbar spinal stenosis with some secondary advantages.

Humans

Feasibility of implementation, diagnostic accuracy, and end-user impact of an electronic health record (EHR)-based ureteral stent tracking tool in a pediatric population.

INTRODUCTION & OBJECTIVES: Ureteral stent tracking systems have reduced stent retention in adults, but their accuracy and impact in pediatrics have been minimally explored. With low event rates in children, such tools may yield high false positives, raising questions on balancing event prevention with provider burden. We aimed to evaluate the feasibility, diagnostic accuracy, and end-user impact of an Electronic Surveillance Tool for Evaluating Nephroureteral stent Tracking (eSTENT) at our institution. STUDY DESIGN: eSTENT, implemented in 1/2024, flags ureteral stents at risk for retention based on implant documentation, expected explant date, and explant documentation. Monthly reports are generated for stents missing explant documentation. We retrospectively evaluated the diagnostic performance of eSTENT from 1/2024-8/2025 at our pediatric hospital. A usability survey including a validated 1-7 implementation score (higher = easier implementation) was distributed to pediatric urologists and operating room nurses. RESULTS: Of 172 cases with ureteral stent placement, eSTENT flagged 28 events (16%) in 24 patients. Of these, 26 represented documentation gaps where explant had been appropriate. Two flags had no documentation of explant, representing near miss events that were identified. No retained stents occurred, consistent with high sensitivity and modest specificity. There were no flags in the last 6 months of the study period. Survey response rate was 100% for surgeons and 55% for nurses. Before eSTENT, stents were not routinely tracked. All surgeons and 93% of nurses reported no added burden, despite occasional misidentification of retained stents. Three surgeons found eSTENT beneficial, four were neutral, and free-text responses generally cited eSTENT's "fail safe" nature as positive. Nurses suggested improvements, including user support and integrated documentation reminders. The average implementation score among both groups was 6/7, indicating easy adoption. DISCUSSION: While the impact of stent tracking tools in adult literature has been positive, our study emphasizes the feasibility of broader adoption at a pediatric hospital. Integration of eSTENT may avoid the potentially devastating consequences of a retained stent. Prioritizing sensitivity over specificity appears acceptable for a "never event" in patient safety. Our study is limited by the retrospective nature of data collection and survey bias. CONCLUSIONS: Though no stents were retained in the study period, eSTENT appropriately flagged two cases without added burden to most end-users. Further optimization is warranted, but adoption in pediatric centers may enhance care reliability.

Humans

New World screwworm: a re-emerging parasitic threat.

PURPOSE OF REVIEW: New World screwworm (NWS) is an emerging parasitic threat in Central America and Mexico, which is spreading northward into the southern United States. Here we highlight the changing epidemiology, lifecycle of the NWS fly, clinical presentation, identification, treatment, and potential complications of NWS myiasis. RECENT FINDINGS: Despite decades of successfully containing NWS flies south of the Darien Gap in southern Panama, NWS flies reemerged in the Central America region in 2023 and have continued to spread northward ever since. On 3 June 2026, United States Department of Agriculture (USDA) confirmed the identification of an NWS infestation in a young calf in southern Texas. In addition to describing the current epidemiology of the NWS outbreak, we present information about clinical presentation and management of NWS myiasis in patients and include representative cases of patients who experienced NWS myiasis. SUMMARY: This review provides important epidemiologic and clinical updates to an emerging parasitic threat so clinicians can understand the risks and clinical management for patients with suspected NWS myiasis.

Animals

Clinical Performance of Bulk-Fill Versus Incremental Composite Placement Approaches in Vital Posterior Teeth: A 24&#x2009;Months Randomized Controlled Trial.

BACKGROUND: Composite resin placement technique may influence marginal integrity, polymerization stress distribution, and long-term clinical performance of posterior restorations. This randomized controlled clinical trial evaluated the 24-month clinical performance of four different placement techniques in Class I posterior composite restorations. METHODS: Fifty patients aged 20-35&#x2009;years presenting with four occlusal carious lesions each were enrolled, resulting in 200 restorations. Cavities (4-5&#x2009;mm depth) were prepared according to caries extension. Restorations were randomly allocated into four equal groups (n&#x2009;=&#x2009;50) according to placement technique: stamp technique, snowplow technique, modified incremental "pizza" technique, and bulk-fill technique. All materials were applied following manufacturers' instructions. Clinical evaluation was performed at baseline and after 6, 12, and 24&#x2009;months using FDI criteria. Functional (fracture/retention, marginal adaptation), esthetic (marginal staining, anatomical form), and biological (postoperative sensitivity, secondary caries) properties were assessed by two calibrated evaluators. Statistical analysis was performed at a significance level of &#x3b1;&#x2009;=&#x2009;0.05. RESULTS: Thirty-eight patients with a total of 152 restorations were evaluated at the end of the 24&#x2009;months in line with FDI at the end of the study with 76% recall rates. No statistically significant differences were observed among groups regarding fracture/retention or secondary caries (p&#x2009;>&#x2009;0.05). Marginal adaptation and marginal staining demonstrated minor deterioration over time across all groups, with statistically significant intergroup differences found (p&#x2009;<&#x2009;0.05). Postoperative sensitivity was minimal and transient in all groups with no significant difference (p&#x2009;=&#x2009;0.181). CONCLUSIONS: Within the limitations of this 24-month follow-up, the four placement techniques demonstrated comparable clinical performance in Class I posterior composite restorations. Selection of technique may therefore be guided by clinical preference and procedural efficiency rather than differences in short-term clinical outcomes. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT07415317.

Humans

Double-Axis Maxillary Skeletal Expander Suggests Higher Expansion Efficiency in Early Activation: A Finite Element Analysis.

INTRODUCTION: Conventional single-axis maxillary skeletal expanders (MSE) have some drawbacks, such as limited control over maxillary expansion and possible asymmetric expansion between the anterior nasal spine (ANS) and posterior nasal spine (PNS). This report introduces a double-axis maxillary skeletal expander (DAMSE) concept to overcome these drawbacks and enhance the efficiency of maxillary skeletal expansion. MATERIALS AND METHODS: Five different DAMSE designs were compared with a conventional single-axis MSE. Finite element analysis was performed to analyse their expansion efficiency, stress magnitude and distribution occurring in a simplified bone model. RESULTS: DAMSE outperformed the single-axis MSE and provided better control over ANS and PNS expansion. During early activation, the highest expansion efficiency (31.7%) was achieved by DAMSE Model V, 13% more efficient than the single-axis MSE. This efficiency was increased to 100.8% by combining the DAMSE Model V with midpalatal suture surgery. However, with the simplified bone model, the current study could not demonstrate that DAMSE can resolve the issue of asymmetric expansion between ANS and PNS. CONCLUSIONS: An appropriately designed DAMSE can be a promising tool for maxillary expansion treatment. DAMSE offers more efficient treatment than the conventional single-axis MSE while maintaining similar levels of patient comfort and invasiveness.

Finite Element Analysis

A systematic literature review of cultural concepts taught by pharmacist preceptors during pharmacy student experiential placements.

BACKGROUND: Cultural concepts such as cultural intelligence, awareness, competency and safety are essential in guiding culturally responsive care in health professional practice. Pharmacist preceptors play a pivotal role in sharing both clinical and cultural safe practice with pharmacy students. Culturally responsive care can contribute to achieving health equity, which is especially important for Indigenous communities. AIM: To review literature on cultural concepts in pharmacist preceptorship practices, and how these concepts are taught and communicated to pharmacy students during experiential learning. METHOD: The systematic review followed the PRISMA 2020 guideline. Scopus, PubMed, and Google Scholar were used to identify articles specific to pharmacist preceptors and pharmacy students published between 2015 and 2025, and available in English. RESULTS: Three full-text articles met the inclusion criteria. Major themes and subthemes were identified; pharmacist preceptors lacked preparedness to teach cultural concepts, resulting in variability in preceptors' understanding of cultural concepts and confidence in fulfilling preceptor responsibilities, underutilised structured frameworks to guide students' learning, challenges with preceptorship due to limited resources and support, and the influence of preceptorship on student learning, which impacted students' learning and competency. CONCLUSION: Pharmacy students had minimal exposure to culturally informed pharmacist preceptorship. It is likely that pharmacist preceptors require country-specific educational resources to support culturally safe preceptorship. Future research is required to substantiate these findings, and to guide culturally responsive practice and promote equitable health outcomes in diverse populations.

Humans

Comparison of short-term clinical outcomes and patient satisfaction between intraoral scanning and conventional impressions for complete-arch implant prostheses: a pilot RCT.

OBJECTIVE: To compare framework passive fit, subjective evaluations, and short-term clinical outcomes between conventional impressions (CI) and intraoral scanning (IOS) for complete-arch implant-supported fixed dental prostheses (CIFDPs). METHODS: In this randomized controlled trial, 22 patients were allocated to the CI or IOS groups. All participants received a definitive one-piece CIFDP. The primary outcome was framework passive fit, assessed using the Vision and Tactile Score (V&T score), which included framework lift-off, the single-screw test, the full-screw test, smoothness of screw insertion, and radiographic gap assessment. Secondary outcomes included operator evaluation, patient satisfaction using a visual analog scale (VAS), early implant survival, marginal bone loss (MBL), modified Plaque Index (mPII), and complications at the 6-month follow-up. RESULTS: Twenty-two patients were enrolled (CI: n = 11; IOS: n = 11), and one patient in the CI group was lost to follow-up. No statistically significant difference in the V&T score was observed between the CI and IOS groups (4.66 &#xb1; 0.17 vs. 4.65 &#xb1; 0.28; P = 0.93). The operator reported greater nervousness during the CI procedure than during IOS (21.82 &#xb1; 15.69 vs. 8.64 &#xb1; 7.47; P < 0.05). Patients in the CI group reported significantly greater discomfort, including nausea and anxiety, than those in the IOS group (P < 0.05). At the 6-month follow-up, the early implant survival rate was 100% in both groups. No significant differences were found between the groups in MBL (0.09 &#xb1; 0.09 vs. 0.06 &#xb1; 0.10 mm; P = 0.43) or mPII (0.10 &#xb1; 0.12 vs. 0.10 &#xb1; 0.28; P = 0.99). CONCLUSION: IOS and CI achieved comparable short-term clinical outcomes in patients who met the predefined inclusion criteria, including controlled implant number, spacing, and angulation. IOS provided a more favorable experience for both operators and patients. CLINICAL SIGNIFICANCE: In complete-arch implant restorations, intraoral scanning may provide clinical outcomes comparable to those of conventional impressions while improving patient comfort.

Humans

Evaluation of a cornea-specialized large language model for diagnostic and management accuracy in complex corneal cases.

PURPOSE: To evaluate whether a cornea-specialized large language model (LLM) enhanced with retrieval-augmented generation (RAG) improves clinicians' diagnostic and management accuracy in complex corneal cases compared to a general-purpose GPT-4o model and unaided clinician performance. METHODS: This prospective, randomized, masked evaluation study involved three cornea trainees who each independently reviewed 39 real-world corneal cases under three experimental conditions: unaided, GPT-4o-assisted, and assisted by a cornea-specialized GPT-4o model. The cornea-specialized model was constructed by embedding over 200 publicly available Wikipedia articles into GPT-4o's RAG framework. Participants provided open-ended diagnoses and selected the next-step management options (multiple choice). They were allowed up to three GPT-4o queries per case, and the AI-assisted arms were randomized to minimize bias. Accuracy for both tasks was compared against expert reference standards using McNemar's test. RESULTS: Diagnostic accuracy was 48.7%, 20.5%, and 38.5% unaided, improving to 69.2%, 46.2%, and 59.0% with general GPT-4o (p<0.04). The cornea-specialized GPT-4o further improved accuracy to 71.8%, 48.7%, and 74.4%, with improvements over unaided performance for all clinicians (p<0.01). For next-step decisions, unaided accuracy was 76.9%, 87.2%, and 59.0%. With the specialized model, Ophthalmologist 3 improved to 71.8% (p<0.05), Ophthalmologist 1 remained high at 82.1%, and Ophthalmologist 2 declined to 64.1% (p<0.05). CONCLUSIONS: A cornea-specialized LLM enhanced with RAG improved diagnostic accuracy in complex corneal cases, particularly among clinicians with lower baseline performance. Effects on management accuracy were inconsistent. Future studies should explore the use of open-ended management tasks and examine whether smaller, curated retrieval corpora yield better model performance.

Humans

Artificial Intelligence for Diagnosing Meibomian Gland Dysfunction: A Systematic Review and Meta-Analysis of Diagnostic Test Accuracy Studies.

PURPOSE: To identify, appraise, and synthesize the performance of artificial intelligence-based meibography reading as compared with human graders in diagnosing meibomian gland dysfunction. METHODS: We followed Cochrane methodology and reporting guidelines for diagnostic test accuracy reviews. To assess potential risk of bias and applicability, we used a modified Quality Assessment of Diagnostic Accuracy Studies-2 checklist. We applied bivariate logistic models to estimate summary sensitivity and specificity when appropriate and used the GRADE framework to rate the certainty of the evidence. RESULTS: We identified 14 eligible studies involving 5511 predominantly middle-aged participants (average age: 27-55 years) who were primarily female (&#x2265;54.5%). A total of 18,926 meibography images were obtained through noncontact infrared (11 studies) or in vivo confocal microscopy (three studies). Two studies reported external validation of deep learning models, 12 reported internally validated models, and one reported both. All but one study had high risk of bias in at least one domain; 12 studies raised high or intermediate concern about applicability. Based on three external evaluations, the summary sensitivity and specificity for diagnosing meibomian gland dysfunction from normal glands were 97.5% (95% confidence interval: 77.5%-99.8%) and 85.5% (95% confidence interval: 47.3%-97.5%). Sources of heterogeneity in internally validated models included study population, case mix, and others. The overall evidence was very low to low certainty because of imprecision, high risk of bias, and concerns about applicability. CONCLUSIONS: Artificial intelligence-based meibography grading appears less accurate than human graders. Future studies should adopt rigorous designs, including a more diverse participant pool (or image set), and external validation.

Humans

Diagnostic accuracy of bronchoalveolar lavage fluid-based testing for pulmonary cryptococcosis: A systematic review and meta-analysis.

BACKGROUND: Pulmonary cryptococcosis(PC) presents diagnostic challenges because of its non-specific clinical and radiological manifestations. Bronchoalveolar lavage fluid (BALF)-based testing, which includes latex agglutination (LA) and lateral flow assay (LFA), offers a minimally invasive diagnostic method, yet its pooled diagnostic accuracy remains unclear. METHODS: We systematically searched PubMed, Embase, Cochrane Library, and Scopus from inception to May 2026. Studies evaluating BALF-based testing for PC with extractable 2 &#xd7; 2 data were included. The methodological quality of relevant studies was assessed by the QUADAS-2 tool. Pooled sensitivity, specificity, likelihood ratios, and diagnostic odds ratio (DOR) were estimated using a bivariate random-effects model. Subgroup analyses were performed by testing method and reference standard type. Heterogeneity was evaluated through paired forest plots, HSROC visualization, and exploratory bivariate meta-regression. RESULTS: The pooled sensitivity was 0.87 (95% CI: 0.81-0.91), and the specificity was 0.99 (95% CI: 0.982 - 0.995). The pooled positive likelihood ratio (PLR) was 88.00 (95% CI: 47.39 - 163.42), the negative likelihood ratio (NLR) was 0.13 (95% CI: 0.09 -0.20), and the DOR was 658.50 (95% CI: 285.36-1519.55). No significant threshold effect or publication bias was detected. Exploratory meta-regression suggested a possible assay-method effect in the joint model (P = 0.03), mainly driven by specificity (P = 0.01). CONCLUSIONS: The study demonstrates the high accuracy of CrAg in BALF for the diagnosis of pulmonary cryptococcosis, supporting its role as an important adjunctive diagnostic tool, particularly when tissue biopsy is not feasible or rapid results are needed. Larger prospective studies with standardized protocols are needed to validate these estimates.

Humans

Diagnostic accuracy of nuclear STAT6 immunohistochemistry for solitary fibrous tumour: a systematic review and meta-analysis.

Nuclear STAT6 immunohistochemistry is the diagnostic surrogate for the NAB2::STAT6 fusion of solitary fibrous tumour (SFT); its sensitivity is established, but specificity varies for unexamined reasons. This review quantified pooled accuracy and tested whether antibody clone and nuclear threshold govern specificity. PubMed, Scopus and Web of Science were searched to 29 June 2026 for studies reporting nuclear STAT6 immunohistochemistry against a reference standard (NAB2::STAT6 confirmation and/or expert consensus) in SFT and comparators, with extractable two-by-two data. Two reviewers screened, extracted data and applied QUADAS-2. A bivariate generalised linear mixed model gave summary sensitivity and specificity, and exploratory subgroup analysis and meta-regression tested antibody clone, anatomical site and reference-standard type. Twenty-three studies (1216 SFT and 4715 comparators) were included. Summary sensitivity was 98.7% (95% confidence interval 96.7-99.5) and specificity 99.1% (97.8-99.6); the diagnostic odds ratio was approximately 8656. The monoclonal YE361 subgroup (8 studies) reached specificity 99.9% (99.3-100), with one false positive among 861 comparators, versus 98.1% (96.0-99.1) for polyclonal and other antibodies. False positives concentrated in dedifferentiated liposarcoma and prostatic stromal tumours. Estimates were stable after removing studies at higher risk of bias (98.9%/99.1%) and on leave-one-out analysis; the Deeks test was non-significant (p&#xa0;=&#xa0;0.08). Nuclear STAT6 immunohistochemistry is therefore highly sensitive and specific for SFT, and the residual specificity loss is structured and largely avoidable: the monoclonal YE361 read at a strict nuclear threshold is preferred, with MDM2 and CDK4 applied to exclude dedifferentiated liposarcoma when nuclear STAT6 is unexpectedly positive.

Humans