Search PubMedSearch

SEARCH · Search PubMed

Results for “scalpel blade”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

4 recordsLinked to original sources

The use of diode laser and scalpel blade in stage-two dental implant surgery: a comparative study.

OBJECTIVE: The use of lasers in dental implant procedures raises questions regarding the preservation of keratinized tissues and implant outcomes. This study aimed to compare the clinical effects (pain and impression time) and soft tissue healing (keratinization, peri-implant probing, bleeding, and healing) of diode lasers and scalpels used during stage-two dental implant surgery. METHOD AND MATERIALS: A prospective randomized clinical trial with a 1:1 allocation ratio was conducted. The study included 30 patients, each with a single, fully osseointegrated implant. Patients were categorized into two groups. The study group underwent stage-two implant surgery using a 970-nm diode laser. In the control group, implants were exposed using a conventional surgical blade. A comparison between the diode laser and conventional scalpel groups was made based on clinical outcomes (pain and impression time) and soft tissue healing (keratinization, peri-implant probing, bleeding, and healing). Data were analyzed using a paired t test. RESULTS: Pain intensity significantly decreased from immediate postoperative to 7 days in both scalpel (49.87 ± 6.78, t = 28.48, df = 14, P .001) and diode laser (7.67 ± 7.58, t = 3.91, df = 14, P = .002) groups. Immediately after surgery, pain scores were significantly higher in the scalpel group compared with the diode laser group (94.53 ± 4.45 vs 46.93 ± 5.85, t = 25.076, df = 26.151, P .001). Although pain decreased in both groups by day 7, the scalpel group continued to exhibit significantly greater pain (44.67 ± 5.96 vs 39.27 ± 3.73, t = 2.974, df = 23.513, P = .007). Impression time (P = .231) and gingival keratinized tissue (P = .736) did not differ significantly between the scalpel and diode laser approaches. At week 6, the scalpel group exhibited a significantly higher mean peri-implant bleeding index (2.60 ± 0.507) compared with the laser group (0.07 ± 0.258, P .001). However, after 12 weeks, no significant difference was observed (1.58 ± 0.19 vs 1.55 ± 0.21, P = .748). Laser surgery produced significantly better early wound healing at all intervals (P .001), while intraoperative bleeding was more common with the scalpel technique than with the diode laser (100.0% vs 66.7%, P = .042). CONCLUSION: Compared with the scalpel method, the diode laser method resulted in a significant reduction in pain intensity, improved wound healing, and less peri-implant bleeding during the stage-two dental implant surgery.

Humans

Re-evaluating pediatric laryngoscope blade size recommendations: Comparable intubation performance across blade sizes in pediatric manikin models.

BACKGROUND: Pediatric airway management traditionally emphasizes strict adherence to age-based laryngoscope blade size recommendations, despite limited empirical validation. OBJECTIVES: To evaluate whether intubation performance varies across a range of blade sizes, and whether a Macintosh 2 blade performs comparably across multiple pediatric age groups in a simulation setting. METHODS: We conducted a randomized crossover simulation study using three pediatric airway manikins (neonate, infant, and child age groups). Emergency medicine residents and faculty physicians performed intubations using multiple laryngoscope blade types and sizes, including standard and nonstandard options. Primary outcomes were intubation time and first-attempt success. Secondary outcomes included complications and operator-rated ease of glottic view and tube passage. Between-blade differences were estimated with 95% confidence intervals. RESULTS: Across manikin sizes and blade types, intubation times were short and first-attempt success rates exceeded 98% in most conditions. Performance remained consistent even with blade sizes outside conventional age-based recommendations. Between-blade differences in intubation time were small, and complication rates were low across conditions. The Macintosh 2 blade performed comparably across all manikin sizes, with similar intubation times, high success rates, and favorable ease ratings. CONCLUSIONS: Intubation performance in pediatric manikin models was similar across a wide range of blade sizes. These hypothesis-generating findings warrant prospective clinical evaluation of simplified blade selection strategies for pediatric intubation.

Manikins

Prostate morcellation devices: a systematic review and meta-analysis of clinical outcomes and efficiency.

OBJECTIVE: To systematically evaluate the efficiency and safety of different prostate morcellators used during prostate enucleation for benign prostatic hyperplasia (BPH). METHODS: A systematic review was performed according to the Preferred Reporting Items for Systematic Review and Meta-analyses guidelines. PubMed/Medline, Scopus, and Web of Science were searched for studies published between October 2012 and May 2025. Studies reporting clinical outcomes of morcellators used during prostate enucleation were included. Primary outcome was morcellation efficiency (g/min). Secondary outcomes included intraoperative complications, device malfunction, and cost when available. Risk of bias (RoB) was assessed using the Risk Of Bias In Non-randomised Studies of Interventions (ROBINS-I), RoB 2 tool, and European Association of Urology case-series criteria. Random-effects meta-analyses and multilevel meta-regression adjusted for prostate volume were conducted. RESULTS: A total of 22 studies comprising 5980 patients were included, most undergoing holmium laser enucleation of the prostate. The most frequently evaluated devices were the Piranha™ (Richard Wolf GmbH, Knittlingen, Germany) and Lumenis VersaCut™ (Lumenis Ltd., Yokneam, Israel; 12 and 13 studies, respectively), followed by DrillCut™ (Karl Storz SE & Co. KG, Tuttlingen, Germany), MultiCut™ (Asclepion Laser Technologies GmbH, Jena, Germany), and Cyber Blade™ (Quanta System SpA, Milan, Italy) systems. Unadjusted weighted mean morcellation efficiency was 7.80 g/min (95% confidence interval [CI] 6.26-9.34 g/min) for Piranha, 4.70 g/min (95% CI 3.61-5.79 g/min) for VersaCut, 5.90 g/min (95% CI 3.16-8.64 g/min) for DrillCut, and 9.59 g/min (95% CI 4.78-14.39 g/min) for MultiCut. In volume-adjusted meta-regression using Piranha as reference, VersaCut remained significantly less efficient (-2.75 g/min; 95% CI -4.58 to -0.92 g/min; P = 0.003), with an even greater difference in prostates >70 mL (-4.34 g/min). Bladder mucosal injury was the most frequently reported complication; however, relatively rare across all devices. Meta-analysis demonstrated a significantly higher risk with VersaCut compared to Piranha (risk ratio 3.22, 95% CI 1.81-5.71), with low heterogeneity. CONCLUSION: This systematic review provides a contemporary clinical benchmark of the efficiency and safety of currently available prostate morcellators. Oscillating blade systems, particularly the Piranha morcellator, demonstrated higher morcellation efficiency and a more favourable safety profile than reciprocating blade devices, with the largest performance differences observed in patients with larger prostates.

Humans

A framework for delivering real-time, instrument-relative navigation in transoral robotic surgery.

Transoral robotic surgery (TORS) is a minimally invasive, inside-out technique that, compared with traditional open approaches, provides fewer post-operative complications, shorter hospital stays, and improved survival for early-stage head and neck cancer. However, TORS is limited by its steep learning curve and poor visualization of deep tumor margins. This randomized crossover study evaluated a surgical navigation system's potential to enhance accuracy and user experience with real-time, instrument-relative feedback. Seven Teflon beads (d = 2.381 mm) were embedded at the tongue base of a porcine pharynx-and-larynx model. Tongue blade compression and retraction were applied to the model to mimic intraoperative tissue deformation, reproducing the anatomical shifts that occur relative to preoperative imaging. Eight participants used the da Vinci Surgical system to localize the beads by placing pins under two conditions: (a) preoperative computed tomography with no navigation; (b) model-based visual navigation with quantitative instrument-to-target metrics. Surgical accuracy was determined by calculating the target localization error (TLE, pin-to-bead Euclidean distance) and the angular error (AE, pin axis trajectory to bead). Accounting for training level and bead depth, surgical navigation reduced TLE by 5.44 mm (95% CI, 4.02-6.86 mm; p = 2.00e-11) and AE by 8.47 degrees (95% CI, 6.21-10.72 degrees; p = 5.17e-11). Impressions of the system were generally favorable using a 5-point Likert survey and task duration (p = 0.26) or cognitive workload via the NASA-Task Load Index (p = 0.22) were not significantly affected. The navigation system demonstrated translational promise, offering improved target localization accuracy and more consistent performance across experience levels, two critical determinants of surgical quality in TORS.

Robotic Surgical Procedures