Search PubMedSearch

SEARCH · Search PubMed

Results for “noninferior”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

7 recordsLinked to original sources

Choice of Anesthesia in Microelectrode Recording-guided Deep Brain Stimulation Surgery for Parkinson's Disease (CHAMPION): A Noninferiority Randomized Controlled Trial.

BACKGROUND: Deep brain stimulation for Parkinson's disease is often performed under conscious sedation or general anesthesia. However, anesthetic agents may influence intraoperative microelectrode recording, and the optimal anesthesia method for microelectrode recording remains unclear. This study compared general anesthesia and conscious sedation in preserving microelectrode recording signal intensity during deep brain stimulation. METHODS: In this prospective, noninferiority randomized controlled trial, patients with Parkinson's disease (United Kingdom Brain Bank criteria) undergoing elective bilateral surgery were randomized 1:1 to the conscious sedation or the general anesthesia group. During surgery, a desflurane anesthetic titrated against the quality of the electrophysiologic signal was applied in the general anesthesia group, whereas patients in the conscious sedation group received dexmedetomidine anesthesia. The primary outcome was the proportion of patients with high-quality microelectrode recording (normalized root mean square greater than 2.0), assessed postoperatively off-line. Secondary outcomes included operation and recording duration, 6-month clinical efficacy, and complication rates. RESULTS: Of 188 randomized patients (94 general anesthesia, 93 conscious sedation), desflurane anesthesia was noninferior for high normalized root mean square proportion (89.4% vs . 90.3%; difference, -0.96%; 95% CI, -9.62 to 7.70). The general anesthesia group had shorter operative time (difference, -9.07&#x2009;min; 95% CI, -13.99 to -4.14; P < 0.001). At 6 months, changes in Unified Parkinson's Disease Rating Scale score (difference, -2.50; 95% CI, -7.20 to 2.20; P = 0.297), levodopa equivalent daily dose (difference, -58.4&#x2009;mg; 95% CI, -133.56 to 16.75; P = 0.128), and complication rates (general anesthesia: 10.9% vs . conscious sedation: 8.9%; P = 0.655) were comparable between the groups. CONCLUSIONS: General anesthesia is noninferior to conscious sedation for microelectrode-guided subthalamic nucleus deep brain stimulation, providing equivalent signal intensity and clinical outcomes while improving procedural efficiency, supporting its use as a valid clinical option.

Humans

MIS-TLIF Versus Open TLIF in Combined Lumbar Stenosis and Low-Grade Spondylolisthesis : Of Discharge Timing and Treatment Pricing.

STUDY DESIGN: An open-label, randomized, noninferiority clinical trial. OBJECTIVE: To determine the effectiveness of the MIS-TLIF over the O-TLIF in patients with symptomatic lumbar stenosis combined with low-grade spondylolisthesis by comparing the clinical efficacy and safety. SUMMARY OF BACKGROUND DATA: In patients with combined lumbar spinal stenosis and spondylolisthesis, it remains uncertain whether minimally invasive fusion surgery is noninferior to the open approach. MATERIALS AND METHODS: We conducted an open-label, noninferiority trial involving patients with symptomatic lumbar stenosis combined with low-grade spondylolisthesis. Patients were randomly assigned in a 1:1 ratio to undergo either MIS-TLIF or open TLIF surgery. The primary endpoint was the reduction in the Oswestry disability index (ODI) score from baseline to three months postsurgery, with a noninferiority margin of 12 points. Secondary outcomes included three-month changes from baseline in back and leg pain, neuropathic pain, satisfaction with treatment, intraoperative data, and cost-effectiveness. RESULTS: In the modified intention-to-treat population, the mean difference was 0.4, with the corresponding 90% CI of -5.7 to 6.5, having a lower bound below the noninferiority margin of 12. Similar results were obtained by analysis of the per-protocol population. 82.8% of patients achieved the MCID for the ODI. Results for secondary outcomes (clinical scales, complications) showed no significant differences between the treatment groups (all P >0.05). Although the open TLIF group had a hospital stay that was 1.5 days longer ( P =0.005) and required additional analgesia more frequently ( P =0.026), direct costs were 10.5% higher in the MIS-TLIF group ( P <0.001). CONCLUSIONS: This is the first high-quality study comparing open TLIF and MIS-TLIF with a validated primary endpoint. Among patients with combined lumbar degenerative stenosis and degenerative spondylolisthesis, MIS-TLIF resulted in clinical outcomes at three months that were noninferior to those with open TLIF.

Humans

Comparison of a Modified Regimen of Prophylactic Phenylephrine Boluses Versus Variable Rate Infusion During Elective Cesarean Delivery Under Spinal Anesthesia: A Noninferiority Randomized Double-Blind Study.

BACKGROUND: Prophylactic phenylephrine boluses have been found to be as effective as variable rate infusions during elective cesarean delivery but require a higher number of physician interventions to maintain blood pressure near baseline values. Therefore, there is a need to find a feasible regimen of bolus administration that is equally efficacious to the infusion regimen while at the same time requires a comparable number of physician interventions and is thus non-inferior to the infusion regimen. METHODS: Healthy pregnant women with term, uncomplicated, singleton pregnancies undergoing elective cesarean delivery under spinal anesthesia were randomly divided into two groups. The Bolus group received a phenylephrine bolus 100 &#x3bc;g immediately after spinal anesthesia and then at every systolic blood pressure value <90% of the baseline. The infusion group received a prophylactic variable-rate infusion of phenylephrine beginning at 50 &#x3bc;g/min and titrated to maintain systolic blood pressure at 90-99% of baseline. The primary outcome was the number of physician interventions needed to maintain the target systolic blood pressure; the secondary outcomes included phenylephrine requirements, incidence of hypotension/hypertension/bradycardia, umbilical arterial and venous blood gas analysis, Apgar scores, and maternal complications. The primary outcome was analyzed in terms of non-inferiority using a non-inferiority margin of two interventions. RESULTS: Eighty patients were included in the study. The median (interquartile range [IQR]) number of physician interventions was 6 (5-8) in the infusion group and 3 (2-4) in the bolus group (P < .001). The difference of medians (95% confidence interval [CI]) between the two groups was -3 (-4 to -2). Phenylephrine requirements were higher in the infusion group (630 [426-765] &#x3bc;g) compared to the bolus group (300 [200-400] &#x3bc;g; P < .001). Blood pressure was higher at certain time points in the infusion group, but overall accuracy of blood pressure control was not different between the groups. Incidence of hypotension, hypertension, and bradycardia, neonatal outcomes, and maternal complications did not differ between the groups. CONCLUSIONS: The modified regimen of prophylactic boluses is non-inferior to variable rate prophylactic phenylephrine infusion in terms of physician interventions needed to maintain systolic blood pressure within the target range and maternal and neonatal outcomes.

Humans

Development and Crossover Evaluation of an Artificial Intelligence-Assisted System for Solid Pancreatic Lesion Detection and Pancreatic Parenchyma Recognition in Endoscopic Ultrasonography (With Video).

BACKGROUND AND STUDY AIMS: Pancreatobiliary endoscopic ultrasonography (EUS) is technically demanding, and supervised training opportunities are limited. We developed an artificial intelligence (AI) overlay system for detecting solid pancreatic lesions (SPL) and recognizing pancreatic parenchyma (PP) and evaluated its effect on reader performance. PATIENTS AND METHODS: Across six centers, two deep learning-based models were trained using expert-annotated EUS frames. We then conducted a randomized, two-sequence, two-period crossover reader study in which eight endosonographers (five novices and three experts) interpreted image sets with and without AI assistance. The primary endpoint was superiority of sensitivity for SPL detection among novices; key secondary endpoints included specificity and PP recognition. RESULTS: From 118 patients, 120 SPL-positive/negative image sets and 160 PP-positive/negative image sets were constructed. Among novices, AI assistance improved SPL detection sensitivity (88.7% vs. 76.8%, p&#x2009;<&#x2009;0.001) and accuracy (86.4% vs. 78.7%), while specificity met the predefined noninferiority criterion (84.2% vs. 80.5%, p&#x2009;<&#x2009;0.001). For PP recognition, sensitivity increased numerically (86.3% vs. 83.3%) but did not meet the predefined superiority criterion (p&#x2009;=&#x2009;0.095); specificity met the noninferiority criterion (87.8% vs. 81.0%), and accuracy increased from 82.1% to 87.0%. Among experts, sensitivity was maintained for both tasks, whereas specificity increased with AI assistance. CONCLUSIONS: AI assistance improved SPL detection among novice endosonographers. For PP recognition, sensitivity increased without reaching statistical superiority, whereas specificity met the predefined noninferiority criterion. These findings support a potential adjunctive role for AI in EUS interpretation.

Humans

Accelerated Diagnostic Pathways for Suspected Acute Coronary Syndrome in Practice: A Randomized Trial of 0/1-Hour vs 0/3-Hour Troponin Testing.

BACKGROUND: For suspected acute coronary syndrome (ACS), guidelines recommend using high-sensitivity troponins (hs-cTn) in accelerated diagnostic pathways (ADPs) with 0/1-hour recommended over 0/3-hour ADP. However, implementation of these ADPs, with universal use of hs-cTns, has not been directly compared in randomized trials OBJECTIVES: This study sought to compare the efficiency and safety of the European Society of Cardiology (ESC) 0/1-hour and a 0/3-hour ADP when implemented in real-world clinical practice. METHODS: This pragmatic, randomized, noninferiority implementation trial compared the safety and efficiency of clinician decision making using these 2 pathways. To prevent incorporation bias, an independent hs-cTnI was used for formal adjudication using the fourth universal definition of myocardial infarction (MI). Efficiency was judged by the proportion of patients discharged within 4 hours. The safety endpoint was major adverse cardiac events (MACE) within 30 days (adjudicated index or representation type 1 MI, cardiovascular death, and urgent coronary revascularization) for those who were considered not to have ACS and discharged. The noninferiority margin, for absolute difference in sensitivity, between the ESC 0/1-hour and the 0/3-hour ADP was set at 3%, assessed with a 1-sided 97.5% CI. RESULTS: From December 2021 to July 2024, of 13,983 screened 3,543 individual patients with suspected ACS were recruited and consented from 2 major emergency departments in North-West England, with 100% follow-up achieved for all representations to any national hospital. The median age was 60 years (IQR: 49.5-70.5 years), 53% were men, 6.7%, and 7.6% had adjudicated index type 1 MI and MACE within 30 days, respectively. The turnaround time from sample to result for central laboratory hs-cTnT was 81 minutes (IQR: 69-101 minutes). The proportion of patients discharged within 4 hours was relatively low and did not differ substantially (21.8% vs 19.2%, P = 0.07). In addition, the 0/1-hour pathway was noninferior for safety, in patients discharged, compared with the 0/3-hour pathway, absolute difference in sensitivity was +4.2% (1-sided 97.5% CI: -2.5) in favor of the 0/1-hour pathway. The calculated sensitivities were 93.7% (95% CI: 88.4%-97.1%) vs 89.5% (95% CI: 82.7%-94.3%), respectively. CONCLUSIONS: Implementation of the ESC 0/1-hour pathway failed to discharge significantly more patients within 4 hours of presentation compared with the 0/3-hour ADP. In addition, The ESC 0/1-hour was noninferior to the 0/3-hour hs-cTn pathway for safety of discharge, although safety for both pathways was less than that imputed by observational studies. This trial demonstrates that perceived benefits to emergency department efficiency of a reduced sampling interval are mitigated by central laboratory turnaround times as well as system constraints. (Pragmatic Randomised Trial of the ESC 0/&#x200b;1 Versus 0/&#x200b;3 Hour Troponin Pathway [MACROS2]; NCT05322395).

Acute Coronary Syndrome

Recent advances in Strongyloides screening, diagnostics, therapeutics, and management.

PURPOSE OF REVIEW: Strongyloidiasis affects an estimated 30-100 million people globally and can have life-threatening consequences in immunocompromised hosts, yet it remains underdiagnosed due to limited access and performance of available diagnostics. Novel assays and anthelmintics may reshape screening, diagnosis, treatment, and prevention for at-risk populations. RECENT FINDINGS: Advances in molecular diagnostics coupled with robust stool extraction methods have supplanted traditional parasitologic methods in settings where nucleic acid amplification is feasible. Transition from standard immunoglobulin G (IgG)-based immunoassays to the new IgG- and IgG4-based rapid diagnostic tests using recombinant Strongyloides stercoralis nematode immunodominant E antigen (NIE) and/or S. stercoralis immunoreactive antigen (SsIR) has facilitated serologic screening at the point of care. The World Health Organization now conditionally recommends community-wide ivermectin mass drug administration in highly endemic settings. Regarding new treatment options, moxidectin is noninferior to ivermectin with 93-94% cure rates and a longer half-life, while emodepside shows 80-90% predicted cure rates in early trials and offers a mechanistically distinct option. Understanding of immunosuppressed populations at risk for hyperinfection has expanded, prompting updated screening recommendations. SUMMARY: Serologic and molecular tools are improving screening and diagnosis, and moxidectin and emodepside may broaden treatment options, but data in severe disease and special populations remain limited. Priorities include harmonized screening algorithms and prospective studies in high-risk groups.

Humans

Robotic Needle Insertion for CT-guided Percutaneous Biopsy of Thoracoabdominal Lesions: A Prospective Multicenter Randomized Trial.

Purpose To compare safety and feasibility between a novel CT-guided robotic system and the conventional freehand technique for puncture biopsy of thoracoabdominal lesions. Materials and Methods In this prospective multicenter randomized trial, individuals with suspected lesions were enrolled between July 2023 and April 2024 across three university teaching hospitals and randomized to the robot-assisted group (n = 82) or the freehand group (n = 83). Procedure outcomes included the technical success rate, targeting error, number of CT scans and needle adjustments, puncture time, and complications. Descriptive and inferential statistics were calculated. Results A total of 165 participants (mean age, 60 years &#xb1; 10 [SD]; 83 male) were included. Compared with the freehand group, the robot-assisted group demonstrated a higher technical success rate (97.56% [80 of 82] vs 62.65% [52 of 83], P < .001), lower targeting error (mean Euclidean deviation: 1.7 mm &#xb1; 1.1 vs 4.5 mm &#xb1; 3.9, P < .001), and fewer CT scans (mean, 4.3 &#xb1; 1.9 vs 5.2 &#xb1; 2.3; P = .002) and needle adjustments (mean, 0.7 &#xb1; 0.7 vs 1.6 &#xb1; 1.6; P = .003). Despite differences in geometric precision, both groups achieved 100% (82 of 82 and 83 of 83) diagnostic yield. The median puncture time was comparable between groups (5.5 minutes &#xb1; 4.3 vs 4.8 minutes &#xb1; 7.0, P = .50). During lung biopsies, the robot-assisted approach yielded fewer complications compared with the freehand approach (4.88% [four of 82] vs 16.87% [14 of 83], P = .014). Conclusion Compared with the freehand approach, robot-assisted biopsy yielded greater precision and reduced adjustments and complications while demonstrating noninferior diagnostic efficacy and comparable duration. Keywords: Robotic Needle Insertion, Biopsy, Thoracoabdominal Lesions, Robot-assisted Biopsy, CT-guided Intervention, Percutaneous Needle Biopsy, Randomized Controlled Trial, Algorithm Development, CT, Clinical Testing, Interventional-Body, Biopsy/Needle Aspiration, Percutaneous, Thorax, Abdomen/GI, Liver, Lung, Kidney &#xa9;RSNA, 2026.

Humans