Search PubMedSearch

SEARCH · Search PubMed

Results for “medical device regulation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

688 recordsLinked to original sources

An impact assessment of the European medical device regulations implementation - the current status quo.

BACKGROUND: This research aims to assess the current impact of the medical and in-vitro diagnostic devices regulations (MDR/IVDR) on the device industry in the EU, under the lens of postimplementation and the amending regulation, and in advance of the final transition to the IVDR/MDR in the future. RESEARCH DESIGN AND METHODS: A quantitative survey was administered to a diverse cohort of medical device enterprises, ranging from micro to large organizations. RESULTS: The survey indicates that the MDR/IVDR has harmed innovation, leading many manufacturers to seek initial device approval and launch elsewhere before in Europe. There is evidence that some manufacturers have rationalized their existing product portfolios and removed devices from the market as they stated they would in previous industry surveys. The MDR/IVDR has been shown to negatively impact manufacturers, with increased costs related to notified body (NB) fees, maintaining and updating documentation, recertification fees, and hiring additional staff. CONCLUSION: This study provides a current status of the effects of MDR/IVDR on manufacturers and finds that despite amending regulations and other interventions taken by the EU to mitigate regulatory burden, ensure product availability, and address stakeholder concerns, the EU is no longer the market of choice for new products.

Equipment and Supplies

Insights from expert panels on the EU clinical evaluation consultation procedure.

BACKGROUND: The Clinical Evaluation Consultation Procedure (CECP) under the EU Medical Device Regulation aims to strengthen and harmonize the assessment of high-risk medical devices. This review summarizes early insights from expert panels to support improved clinical evaluation practices. RESEARCH DESIGN AND METHODS: This review analyses 34 expert panel opinions derived from 281 CECP submissions between April 2021 and December 2025. Statements from opinions were systematically extracted, de-duplicated, and grouped into thematic categories, with independent review and validation. The analysis focuses on common challenges found during the consultation procedure of the expert panels on the content of the clinical assessment in relation to clinical evidence, benefit-risk assessment, intended purpose alignment, and post-market clinical follow-up planning. RESULTS: Expert panel findings highlight recurrent issues in the sufficiency, consistency, and transparency of clinical evidence, underscoring the need for improved standardization and clearer guidance. CONCLUSIONS: Strengthening documentation quality and alignment across stakeholders will enhance the robustness, efficiency, and predictability of conformity assessments for high-risk medical devices.

Humans

Review of regulatory requirements for benefit-risk assessment for medical devices: uncovering existing methodologies.

INTRODUCTION: A positive benefit-risk profile is a prerequisite for the market approval of medical devices. However, regulations are often criticized for providing limited information on benefit-risk assessment (BRA) despite growing expectations for quantitative methods. A clearer understanding of regulatory requirements, existing methodologies, and unresolved issues is needed. AREAS COVERED: Relevant regulatory documents referencing BRA for medical devices were systematically identified, with a primary focus on the European regulation followed by screening to extract BRA‑related requirements and any explicitly or implicitly described methods. The findings were analyzed and consolidated by BRA context, type, objective, methodological description, and implementation, thereby establishing a basis for the BRA methodological landscape. EXPERT OPINION: BRA is not a single concept, but a set of context‑dependent assessments across lifecycle of a medical device. BRA within clinical evaluation framed into BRAs of risk management holds a pivotal role and is supported by the most detailed methodological guidance, although BRAs in other contexts are important. A structured overview of existing BRA requirements clarifies their treatment across regulatory documents. By differentiating BRA contexts, types, objectives, and required methodological detail, the analysis supports a more transparent understanding of BRA and helps identify priorities for methodological refinement and interface clarification.

Risk Assessment

Copper-Containing Surface Engineering for Soft-Tissue Biomedical Devices: Structure-Function Relationships and Ion Release-Driven Biological Performance, A Systematic Review.

Copper and copper-based materials have gained increasing attention for the functional modification of implantable medical devices intended for prolonged soft-tissue contact, including vascular stents, catheters, and intrauterine devices. Owing to their broad-spectrum antimicrobial activity, redox reactivity, and involvement in angiogenesis and cellular signaling, copper-based systems offer significant potential for multifunctional surface engineering. However, achieving a balance between antibacterial efficacy, corrosion behavior, controlled ion release, and cytocompatibility remains a critical challenge. This PRISMA-compliant systematic review analyzes copper-containing materials and surface modification strategies for soft-tissue biomedical applications. A structured search of Scopus, Web of Science, and PubMed (2015-2025) identified 65 eligible studies. The review encompasses bulk copper-containing alloys, electrochemical and chemical surface modification techniques, physical vapor deposition approaches, and advanced hybrid systems integrating copper with polymers, hydrogels, or metal-phenolic networks. Across the reviewed literature, antibacterial performance was strongly dependent on copper concentration, microstructural distribution, and spatiotemporal ion release profiles. Moderate, well-controlled copper incorporation frequently improved antibacterial efficacy while maintaining acceptable hemocompatibility and cytocompatibility, particularly in vascular and blood-contacting devices. In contrast, excessive copper loading often accelerated corrosion and induced adverse cellular responses. Emerging multifunctional architectures demonstrated improved regulation of biological interactions, enabling simultaneous antibacterial, antithrombotic, and proendothelial effects. Overall, copper-based surface technologies represent a versatile platform for soft-tissue implant modification. Future translational progress will require precise control of copper release kinetics and comprehensive long-term in vivo validation to ensure safety and sustained therapeutic performance. From the authors' perspective, the most promising future direction involves multifunctional copper-based hybrid coatings capable of dynamically regulating ion release, host tissue integration, and antibacterial performance simultaneously. Strategies integrating hierarchical architectures, stimulus-responsive release systems, and clinically scalable fabrication methods are expected to play a key role in translating copper-containing surfaces from experimental concepts toward commercially viable soft-tissue biomedical devices.

Copper

Percutaneous left ventricular assist device in cardiogenic shock associated with and without acute myocardial infarction: a real-world retrospective cohort study.

BACKGROUND: Percutaneous left ventricular assist devices (pLVAD, such as Impella), are increasingly used for cardiogenic shock (CS). Outcomes may differ between acute myocardial infarction-related CS (AMI-CS) and non-AMI CS due to differing pathophysiology and trajectories. METHODS: Using the USA TriNetX Network (2016-2024), we identified adults with CS treated withpLVAD. AMI-CS was defined by MI within seven days of implantation; non-AMI CS included all patients with CS not attributable to acute MI, representing heterogeneous etiologies such as decompensated cardiomyopathy, myocarditis, valvular failure, pulmonary vascular causes, and arrhythmic shock. Patients with recent coronary artery bypass graft (CABG) were excluded. Propensity matching produced two balanced cohorts (n&#x2009;=&#x2009;2,026 each). RESULTS: Among 6,873 AMI-CS and 4,521 non-AMI CS patients, matched groups were similar (mean age 63&#x2009;years, 26% female). AMI-CS had higher mortality at 30&#x2009;days (hazard ratio [HR] 1.19, p&#x2009;=&#x2009;0.002), 90&#x2009;days (HR 1.13, p&#x2009;=&#x2009;0.02), and 180&#x2009;days (HR 1.14, p&#x2009;=&#x2009;0.007). Heart failure (HF) exacerbations (HR 1.21, p&#x2009;<&#x2009;0.001) and pulmonary edema (HR 1.23, p&#x2009;=&#x2009;0.005) were also more common in AMI-CS. Stroke, ventricular arrhythmias, cardiac arrest, acute kidney injury, major bleeding, vascular complications, and hemodialysis were comparable. CONCLUSION: AMI-CS patients supported with pLVAD experienced higher mortality and greater HF-related morbidity than non-AMI CS.

Humans

Efficacy of targeted neuromodulation treatments: a clinical report.

BACKGROUND: Peripheral neuropathy is a debilitating condition characterized by chronic pain, numbness, tingling, burning, and tightness/swelling. Conventional therapies often focus on symptom management, and some patients experience chronic and refractory symptoms. RESEARCH DESIGN AND METHODS: This retrospective clinical analysis evaluated the clinical outcomes of neuromodulation neuropathy treatment using the NeuroGen-Series device in patients with diabetic peripheral neuropathy (DPN) or idiopathic peripheral neuropathy (IPN). 9,805 unique patients who underwent 133,741 treatments between 18 August 2017, and 23 July 2024, were analyzed. Patients were divided into treatment completers (&#x2265;24 sessions) and noncompleters (<24 sessions). Paired t-tests confirmed statistically significant reductions in pre- and post-treatment symptom scores (p&#x2009;<&#x2009;0.001). RESULTS: Among completers, symptom severity decreased by an average of 46.2%. Tingling and pain showed the greatest improvement, while tightness/swelling and numbness showed the least reduction. 64% of patients reported improvement after one session, and 84% reported improvement after 24 sessions. Nonresponders accounted for 5.8% of patients overall. Younger patients and those with higher initial symptom severity were more likely to discontinue treatment. CONCLUSIONS: Overall, neuromodulation treatment resulted in statistically significant reductions in symptom severity, though nonresponders and high attrition rate highlight the need for individualized treatment strategies and further investigation.

Humans

Effectiveness of Wearable Digital Therapeutics in Improving Sleep Outcomes Among Individuals With Insomnia: Systematic Review and Meta-Analysis of Randomized Controlled Trials.

BACKGROUND: Wearable devices are increasingly used for sleep monitoring and as adjunctive treatment. Existing meta-analyses mostly pool composite digital therapies and rarely isolate stand-alone wearables or distinguish between objective and subjective end points. Whether stand-alone wearable interventions improve sleep outcomes in adults with insomnia, and which factors moderate treatment heterogeneity, remains unclear. OBJECTIVE: This study aims to evaluate the effectiveness of wearable digital interventions on sleep outcomes in adults with insomnia versus control strategies and explore moderators of effectiveness, including device-wearing position, intervention duration, and control type, using meta-regression. METHODS: This systematic review and meta-analysis was conducted in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta&#x2011;Analyses) 2020 statement and the PRISMA-S (Preferred Reporting Items for Systematic Reviews and Meta&#x2011;Analyses Literature Search Extension) guideline. Five electronic databases and clinical trial registries were searched from inception to May 18, 2026. Eligible studies were randomized controlled trials (RCTs) evaluating wearable digital interventions in adults with insomnia compared with sham, waitlist, usual care, or active control conditions and had an intervention duration of at least 1 week. Study screening, data extraction, and risk-of-bias assessment were carried out independently by 2 reviewers. Pooled estimates were calculated using a restricted maximum likelihood random-effects model with the Hartung-Knapp-Sidik-Jonkman correction. Heterogeneity was assessed using the I&#xb2; statistic, and 95% prediction intervals (PIs) were calculated for the primary analyses. The certainty of evidence was rated using the GRADE (Grading of Recommendations, Assessment, Development, and Evaluation) approach. RESULTS: Sixteen RCTs (N=910) were included. Wearable digital interventions were associated with a significant reduction in objective sleep-onset latency (SOL; mean difference [MD] -4.52, 95% CI -8.38 to -0.67, PI -9.52 to 0.47 min) and a significant improvement in subjective sleep efficiency (SE; MD 2.00%, 95% CI 1.90%-2.11%, PI 1.85%-2.15%). Subjective total sleep time (TST) also showed a significant increase (MD 19.11, 95% CI 2.98-35.24, PI -16.20 to 54.43 minutes). Meta-regression showed that control type, intervention duration, and device location did not explain the heterogeneity of the insomnia severity index (ISI) (R&#xb2;=0). Sensitivity analysis confirmed the robustness of pooled ISI estimates, and an Egger test indicated no small-study effects (P=.07). Certainty of evidence ranged from moderate to high. CONCLUSIONS: Wearable digital interventions provide selective benefits for objective SOL, subjective SE, and subjective TST in adults with insomnia, with no improvement in overall ISI. Despite statistically significant effects on several sleep parameters, wide PIs, substantial heterogeneity, and limited study numbers indicate preliminary, nonconclusive findings. Wearables should be viewed as affordable adjunctive tools requiring further validation, not substitutes for first-line cognitive behavioral therapy for insomnia. Large-scale, long-term RCTs with standardized protocols and patient-level external validation are required to consolidate the evidence base.

Humans

Glaucoma filtering surgery combined with phacoemulsification in the era of new aqueous humor filtration devices: A systematic review.

We evaluate the efficacy and safety of filtering glaucoma surgeries combined with phacoemulsification (PCE)-including new aqueous humor drainage devices-compared to standalone procedures. We performed a systematic search up to March 23, 2025, including all comparative studies assessing trabeculectomy (TRAB), non-penetrating deep sclerectomy (NPDS), Xen&#xae; Gel Stent (XEN), or Preserflo&#xae; MicroShunt (PMS) combined with PCE, versus the same surgery alone. Key exclusion criteria include inadequate follow-up (less than 12-month), absence of a defined success criterion, more than 50% of loss to follow-up at 12-month, and lens extraction performed without PCE. Main outcome was surgical success at &#x2265;&#x202f;12 months. Secondary outcomes included intraocular pressure (IOP) reduction, decrease in hypotensive medications, and rates of complications. A total of 27 studies were included for analysis. Among studies comparing TRAB/PCE with standalone TRAB, half reported similar success rates, while others favored standalone TRAB, particularly using strict IOP thresholds. Safety profiles were comparable. For NPDS/PCE, data mostly showed equivalent outcomes versus standalone NPDS, with comparable safety. In studies on XEN/PCE and PMS/PCE, results suggested similar rates of surgical success, efficacy in IOP and medication reduction, and safety compared to their stand-alone procedures. Small differences occasionally favored standalone procedures under stricter success definitions. Current evidence suggests that combined filtering glaucoma surgery provides long-term efficacy and safety comparable to standalone, though some subgroups and outcome thresholds may slightly favor standalone approaches. The limited availability of high-quality prospective trials underscores the need for further large-scale robust studies.

Humans

Optimizing smoking cessation pharmacotherapy and counseling for adult primary care patients: a factorial randomized controlled trial.

BACKGROUND: Even with the most effective smoking cessation pharmacotherapies (i.e., varenicline or combination nicotine replacement [C-NRT]), the majority of people ultimately return to smoking. This research explored how to optimize the use of varenicline and C-NRT to promote smoking cessation. METHODS: Primary care patients participated in a 2x2x2x2 factorial experiment that evaluated 4 factors: 1) Medication Type (Varenicline vs. C-NRT [patch&#xa0;+&#xa0;mini-lozenge]), 2) Preparation (pre-quit) Medication (4 Weeks vs. Standard); 3) Medication Duration (Extended [24&#xa0;weeks] vs. Standard [12&#xa0;weeks]); and 4) Counseling Type (Cessation Counseling [4 sessions] vs. Referral Support [2 sessions focused on use of referral resources]). This study was discontinued prior to reaching the proposed sample size (N&#xa0;=&#xa0;608) due to pandemic-related budgetary constraints. RESULTS: Participants (N&#xa0;=&#xa0;496) were 55% women and 45.6% Black individuals. There were no statistically significant main effects of the 4 factors on abstinence at 12, 26 or 52&#xa0;weeks. There was a 3-way interaction between Medication Type, Preparation Medication, and Counseling Type (p&#xa0;=&#xa0;0.04) predicting the primary outcome of biochemically confirmed abstinence at 52&#xa0;weeks; cessation counseling vs. referral support improved varenicline quit rates when 4&#xa0;weeks versus 1&#xa0;week of pre-quit medication was offered. For C-NRT, counseling type did not significantly improve quit rates regardless of the use of preparation medication. CONCLUSIONS: There was no robust evidence that enhanced pre-quit or extended duration of varenicline or C-NRT increased abstinence rates. More intensive counseling may support cessation for different pharmacotherapy regimens. Given the lack of consistent findings, this research should be viewed as exploratory to guide future research.

Humans

Hand Pain and Sensory Deficits: Carpal Tunnel Syndrome: 2026 Revision. Using the Evidence to Guide Musculoskeletal Rehabilitation Practice.

SYNOPSIS: Carpal tunnel syndrome is common in women, manual laborers, and during pregnancy; it is often associated with medical conditions such as obesity and diabetes. The musculoskeletal rehabilitation clinician's approach to managing hand pain and sensory deficits associated with carpal tunnel syndrome should include prescribing a neutral-positioned wrist orthosis plus instructing the patient on how to modify activities, adjust ergonomics, and reduce exposure to risk factors. Here, we present for clinicians the most up-to-date information to guide their work in managing hand pain and sensory deficits associated with carpal tunnel syndrome. J Orthop Sports Phys Ther 2026;56(9):622-623. doi:10.2519/jospt.2026.0502.

Humans

Clinical Trial: Effectiveness and Safety of a Novel Anal Insert Device for Treatment of Faecal Incontinence.

BACKGROUND: Treatment options for medically-refractory faecal incontinence (FI)-including anorectal biofeedback, dextranomer injection, and sacral nerve stimulation-are limited and outcomes are often suboptimal. Anal or vaginal insert devices are infrequently used. AIMS: We evaluated the safety and effectiveness of a new anal insert device (StaySure) in patients with FI. METHODS: Patients with FI for&#x2009;&#x2265;&#x2009;6&#x2009;months and&#x2009;&#x2265;&#x2009;4 moderate or large FI episodes during a 4-week baseline entered a 2-4&#x2009;week fitting/run-in period to individualise device size (10 or 13&#x2009;mm) followed by a 4-week treatment period. Outcomes included effectiveness, safety, and quality of life (QoL). The primary outcome was the proportion achieving a&#x2009;&#x2265;&#x2009;50% reduction in FI frequency. RESULTS: Of 124 enrolled patients, 98, 71, and 61 progressed through the baseline, fitting/run-in, and treatment phases respectively, with few exclusions due to device intolerance. In the intent-to-treat cohort of 59 participants (93% women), mean (SD) number of days with FI declined from 13.2 (7.0) to 6.3 (6.9), and FI weekly episodes declined from 5.4 (6.9) to 2.1 (5.1) (69% reduction; p&#x2009;<&#x2009;0.001) with similar results for both device sizes. The primary endpoint was achieved in 76.3% of participants; 54.2% achieved&#x2009;&#x2265;&#x2009;75% reduction. The FIQoL overall score increased from a mean (SD) of 1.9 (0.6) to 2.3 (0.6) (p&#x2009;<&#x2009;0.001), indicating improved QoL. Improvements in FI frequency, FIQoL exceeded minimal clinically important difference thresholds, confirming clear clinical benefit. No treatment-related serious adverse events were reported. CONCLUSIONS: The StaySure anal insert device is safe, well tolerated, and effective in reducing FI in patients with moderate to severe symptoms refractory to conservative therapies. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT03898778.

Adult

Home-Based Cardiac Rehabilitation Using a Smart Ring and Telephone Counselling: A Randomized Controlled Trial.

BACKGROUND: Home-based cardiac rehabilitation (HB-CR) is a promising alternative to center-based cardiac rehabilitation as it can address several barriers impeding CR implementation because of its enhanced accessibility. However, to date, HB-CR has not garnered adequate attention due to a lack of communication between patients and medical staff. In this study, we aimed to investigate the effectiveness of HB-CR by monitoring the pulse rate (PR) using a smart ring equipped with photoplethysmography. METHODS: Patients with cardiovascular disease were educated on structured HB-CR methods following a symptom-limited cardiopulmonary exercise test (CPET), and were instructed to wear the device during the exercise session. The recorded PR was uploaded to a website via a smartphone and monitored by medical staff. Patients were randomly assigned to one of two groups: intervention or control group. The intervention group received weekly telephone counselling and was encouraged to maintain optimal levels of physical activity. In contrast, the control group only recorded their exercise data without additional interventions. After 3 months of training, the CPET was performed. RESULTS: Among the 64 randomized patients (32 in each group), an intention-to-treat analysis showed that peak oxygen consumption increased over time in both the groups, with a significantly greater improvement in the intervention group. The group-by-time interaction for peak oxygen consumption was statistically significant (estimated mean difference, 2.0 mL/kg/min; 95% confidence interval, 0.7-3.3; P = 0.004). CONCLUSION: HB-CR using a smart device was effective in improving oxygen consumption. However, appropriate monitoring and timely counselling by medical professionals are important for improved outcomes. TRIAL REGISTRATION: Clinical Research Information Service Identifier: KCT0005893.

Humans

One in three patients with positional obstructive sleep apnea does not benefit from positional therapy: Insights from a home-based trial.

PURPOSE: Positional obstructive sleep apnea (POSA) is the most common phenotype of obstructive sleep apnea, yet patient selection for positional therapy (PT) remains suboptimal. With this analysis we aimed to clarify how many patients with POSA may not require PT because they do not habitually sleep supine at home, and how many fail vibrotactile PT despite appropriate indication. METHODS: We conducted a retrospective observational study of consecutive adults with POSA evaluated at a tertiary sleep center between 2021 and 2024. All patients underwent a home-based trial with a neck-based vibrotactile positional therapy device (Night Shift&#x2122;), consisting of monitoring mode followed by therapy mode. Outcomes included the proportion of non-supine sleepers at home, failure rate of vibrotactile PT, device compliance and differences in supine sleep time between diagnostic testing and home monitoring. RESULTS: Of 92 screened patients, 74 met inclusion criteria (mean age 60.3&#x202f;&#xb1;&#x202f;13.2 years; mean AHI 22.9&#x202f;&#xb1;&#x202f;13.3 events/h). Fifteen percent (11/74) did not habitually sleep supine at home, indicating no clinical need for PT, and an additional 14.8% (11/74) failed vibrotactile PT. Overall, 30% of patients were either unlikely to benefit from PT or failed therapy. Non-response was frequently associated with psychotropic or sedative medication use and neurological or sleep-related comorbidities. CONCLUSION: A substantial proportion of patients diagnosed with POSA either do not require or fail vibrotactile treatment in real-world conditions. Incorporating a brief home monitoring and therapy trial into routine clinical practice may optimize patient selection, reduce unnecessary costs, and improve personalized management of POSA.

Humans

Oxygen-controlled gamma-irradiation and annealing enable terminal processing of collagen-based biomaterials.

Gamma irradiation is a widely adopted method for terminal sterilization of medical devices; however, its application to collagen-based extracellular matrix (ECM) materials remains limited due to radiation-induced degradation of structural integrity and mechanical performance. Here, we present an engineered terminal-processing strategy that combines oxygen controlled gamma irradiation (25-30&#xa0;kGy) with post-irradiation dry-heat annealing to preserve ECM functionality while achieving effective sterilization. By modulating oxygen availability during irradiation, this approach alters radical reaction pathways, suppresses oxygen-mediated oxidative degradation, and generates a metastable radical-containing intermediate, which is subsequently converted into a structurally stabilized collagen network through thermal annealing. As a result, the treated matrices preserved ECM integrity and recovered clinically relevant mechanical properties. Furthermore, the process achieved cumulative viral reductions exceeding 6 log10 across a representative panel including enveloped and non-enveloped DNA and RNA viruses, demonstrating compatibility with sterility assurance and viral safety requirements for biologically derived medical devices. Notably, preliminary observations indicate that mechanical integrity can be partially preserved even at elevated irradiation doses up to 50&#xa0;kGy, suggesting potential applicability to sterilization validation frameworks requiring higher assurance levels. Overall, this work establishes a mechanistically grounded terminal-processing paradigm that enables control of radical fate, decouples sterilization efficacy from material degradation, and integrates sterilization, viral safety, and functional preservation into a unified and scalable framework for collagen-based biomaterials. This concept repositions gamma-irradiation from a purely degradative process to a controllable tool for tuning collagen structure and performance.

Gamma Rays

Implementing a novel digital health platform for self-management of postmenopausal osteoporosis: A qualitative study of user experiences, perspectives and implementation outcomes.

BACKGROUND: Osteoporosis self-management requires scalable support, and digital health platforms may meet this need. This study aimed to characterise the experiences and perspectives of postmenopausal women who participated in a 12-month randomised controlled trial (RCT) of a digital voice assistant (DVA) delivered osteoporosis self-management intervention, and to assess key implementation outcomes. METHODS: This was a qualitative analysis of interviews with postmenopausal women from the intervention arm (DVA group) of the RCT. The DVA program broadcast education videos, medication reminders, home-based exercise, nutrition advice and monthly quizzes through a DVA device. Semi-structured interviews were recorded, transcribed and managed in NVivo through reflexive thematic analysis, guided by the Practical Planning for Implementation and Scale-Up and Proctor's implementation outcome taxonomy frameworks. Evidence weighting summarised participant coverage and code density. RESULTS: Twenty-two of 25 (88%) DVA group participants completed semi-structured interviews. Thematic analysis identified seven themes mapped to Proctor's implementation outcomes. Evidence weighting indicated strong support for the intervention's appropriateness and acceptability, moderate support for its adoption, fidelity, feasibility and sustainability, and limited support for costs. Participants valued clear audiovisual guidance, conversation-based interactions with natural language, and flexible home-based access to self-management. CONCLUSION: Digital health platforms for osteoporosis self-management appear feasible, acceptable and sustainable among postmenopausal women. Findings indicate that these platforms are approaching readiness for evaluation in implementation-focused settings, contingent on streamlined content, reliable delivery modalities, accessible user support, clear privacy regulations and pragmatic pricing models.

Humans

Comparison of three tracking methods to assess usage of two pediatric powered mobility devices for young children with cerebral palsy.

Powered mobility devices are underutilized for promoting self-initiated mobility in young children with cerebral palsy due to prioritization of walking, caregiver effort, device characteristics, and environmental factors. Understanding device usage patterns is important to assess the impact of powered mobility interventions on child outcomes. As part of clinical trial (NCT04684576), three objective tracking methods including integrated loggers, Global Positioning System trackers (GPST), and caregiver reported activity logs (CRAL) were compared to provide insights into device usage patterns. Metrics included play session frequency, session duration, total usage minutes, and unique usage days for two powered mobility devices: Modified Ride-on Cars (MROC) and the Permobil Explorer Mini (EM). Twelve children with cerebral palsy used each device for eight consecutive weeks in home and community settings (16&#x2009;weeks total), with device ordered randomized. Results showed no significant differences among tracking methods for the MROC. For the EM, only session duration differed between GPST and CRAL. Correlation analysis revealed variable relationships amongst tracking methods for both devices. The EM was used more frequently than the MROC, with significantly greater total usage minutes and session duration via CRAL, not GPST. The findings highlight the need for reliable tracking technologies that can be used across powered mobility devices.

Child, Preschool

Effect of Music on Pain, Anxiety, and Satisfaction During Intrauterine Device Application: A Randomized Clinical Trial.

This randomized controlled trial aimed to determine the effect of music played during intrauterine device (IUD) insertion on perceived pain, state anxiety, and satisfaction levels. The study was conducted with 70 women who applied to a maternal and child health and family planning center and were randomly assigned to the intervention and control groups using simple randomization. Data were collected using a Demographic Information Form, the State-Trait Anxiety Inventory (STAI-I), and the Visual Analog Scale (VAS), as well as Bluetooth speakers and the musical piece Evgeny Grinko-Valse. Participants in the intervention group listened to music before and during the IUD insertion procedure, whereas the control group received routine care only. Data were analyzed using SPSS version 26 with appropriate descriptive and inferential statistical methods. Women in the music group had significantly lower perceived pain (p&#x2009;<&#x2009;0.001) and state anxiety levels during the procedure (p&#x2009;=&#x2009;0.022), and significantly higher satisfaction levels compared with the control group (p&#x2009;<&#x2009;0.001). In addition, post-procedure state anxiety levels were positively correlated with pain intensity experienced during and after the procedure (r&#x2009;=&#x2009;0.542 and r&#x2009;=&#x2009;0.496, respectively; p&#x2009;<&#x2009;0.001), and negatively correlated with procedural satisfaction (r&#x2009;=&#x2009;-0.652; p&#x2009;<&#x2009;0.001). These findings suggest that listening to music during IUD insertion may help reduce pain and anxiety while potentially enhancing patient satisfaction. Trial Registration: NCT06215183.

Humans

Assessment of Surgical Salvage Outcomes for Exposed Cranial Neuromodulating Devices.

OBJECTIVES: Implanted neuromodulating devices (NMDs) such as cochlear implants (CIs) and deep brain stimulators (DBSs) are commonly used in modern medicine. Rarely, complications arise post-operatively, including hardware exposure. Traditional teaching suggests that these devices require removal if exposed; however, surgical salvage is a high risk, high reward alternative. We review our single institution experience managing NMD exposure with surgical salvage. METHODS: Retrospective chart review was performed on individuals who had a NMD implanted and underwent an attempt at surgical salvage for exposure during the study period (January 01, 2021 through December 31, 2023). Study outcome success was defined as maintaining a functional NMD 1&#x2009;year after salvage was attempted. Surgical techniques associated with successful salvage were compared. RESULTS: Nine of 729 patients (1.2%) implanted with NMDs experienced hardware exposure during this 2-year study period. Nine subjects were referred for NMD salvage; however, only 6 of 9 subjects (66.7%, CI&#x2009;=&#x2009;3; DBS&#x2009;=&#x2009;3) underwent NMD salvage attempts. Four of the subjects had successful salvage demonstrated successful salvage with a functioning NMD and without wound healing concerns 1&#x2009;year after their salvage procedure. CONCLUSIONS: Classic teaching states that exposed NMDs require explantation. However, this approach necessarily imposes time without benefit from the NMD between explantation and reimplantation. Our experience demonstrates that surgical salvage can be a successful alternative for the majority (66.7%) of individuals.

Humans