Search PubMedSearch

SEARCH · Search PubMed

Results for “mass spectrometry-based proteomics”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

484 recordsLinked to original sources

Occupationally relevant vibrations and the brain: frequency-dependent proteomics signatures in a rat model.

INTRODUCTION: Occupational exposure to whole-body vibration (WBV), particularly in agricultural environments, has been associated with adverse cognitive and physiological effects. This study examined the neurophysiological impact of WBV in a rat model at 4 Hz and 30 Hz, frequencies representative of off-road and on-road vehicle operation. METHODOLOGY: Forty-four Sprague-Dawley rats were assigned to control (0 Hz), low-frequency (4 Hz), or high-frequency (30 Hz) vibration conditions. After three days of exposure, brain tissues were collected and analyzed using mass spectrometry-based proteomics to identify differentially expressed proteins. RESULTS: Proteomic profiling revealed distinct, frequency-dependent alterations in brain protein expression. Compared with controls, 32 cognition-related proteins were differentially regulated at 4 Hz and 29 at 30 Hz, with 13 differing between the two vibration conditions. Principal component analysis showed clear separation among groups, indicating unique proteomic signatures for each exposure frequency. Functional enrichment and protein-protein interaction analyses demonstrated involvement of synaptic plasticity, cytoskeletal organization, calcium regulation, and neurotransmitter release. Exposure to 4 Hz was associated with the upregulation of proteins involved in calcium homeostasis and synaptic integrity, suggesting potential disruption of cognitive processes. In contrast, 30 Hz increased the expression of proteins related to axonal guidance and neuroprotection, indicating a less clearly adverse response that may reflect adaptive or potentially beneficial effects. DISCUSSION: These findings provide new insight into biological mechanisms underlying WBV-induced cognitive changes and underscore the importance of vibration frequency in shaping neurophysiological outcomes. They also establish a foundation for future studies integrating proteomics with behavioural assessments in animals and humans.

Animals

Metabolomic differences in the Ophiura sarsii complex from the Yellow Sea Cold Water Mass and Bering Sea Cold Pool.

Metabolomics provides a functional readout of cellular physiology and can reveal metabolite-level differences associated with environmental and evolutionary contexts. Here, we used GC-MS- and LC-MS-based metabolomics to characterize metabolic profiles of the Ophiura sarsii complex from the Yellow Sea Cold Water Mass (YSCWM) and the Bering Sea Cold Pool (BSCP). This metabolomics analysis identified 398 LC-MS/MS and 87 GC-MS/MS differential metabolites (DEMs). Marked metabolic differences were observed between the two taxa, involving antioxidant-related metabolites, central carbon-related intermediates, osmolyte-associated compounds, and membrane lipid components. O. sarsii vadicola from the YSCWM showed higher levels of glutathione, glucose, citric acid, D-ribulose 5-phosphate, and unsaturated lipid-related metabolites, indicating differences in antioxidant-related and energy-associated metabolic profiles. By contrast, O. sarsii from the BSCP was characterized by higher levels of sugar alcohols, particularly myo-inositol, together with differences in membrane lipid-associated metabolites. These results provide metabolomics-based evidence for metabolite-level physiological differences between two members of the O. sarsii complex sampled from the Yellow Sea Cold Water Mass and the Bering Sea Cold Pool, while the relative contributions of lineage divergence and site-specific environmental variation remain to be tested experimentally.

Metabolomics

Dynamic lysine acetylation and succinylation of platelet proteins regulates platelet storage lesion: mechanistic insights from multi-omics.

OBJECTIVES: Platelet storage lesion (PSL) severely impairs platelet function during storage, presenting a major hurdle in transfusion medicine; however, the dynamic interplay between global proteomic changes and post-translational modifications (PTMs) underlying these functional deteriorations remains insufficiently characterized. Here, we report the first comprehensive multi-omics analysis integrating global proteomics, acetylomics, and succinylomics to dissect the molecular dynamics during platelet storage. METHODS: We performed quantification of global proteomics, acetylome and succinylome based on TMT-labeled LC-MS/MS analysis, combined with antibody-affinity enrichment and purification. Dynamic molecular changes and functional transformation of platelet were also characterized under proper conditions stored for 1, 3, 5, 7 days, respectively. RESULTS: We systematically characterized 3,609 proteins, 1,308 acetylation sites, and 1,947 succinylation sites across multiple storage time points (D1, D3, D5, D7). We distinct temporal patterns of post-translational modifications, with succinylation showing more extensive coverage than acetylation in platelets. Pathway enrichment analysis revealed extensive metabolic reprogramming involving complement activation, energy metabolism, and cellular detoxification processes. The identification of specific motif patterns provided mechanistic insights into the functional specificity of these modifications. Random forest machine learning identified 20 core regulatory proteins representing critical nodes in PSL development. Furthermore, we employed real - time quantitative polymerase chain reaction (RT - QPCR) to measure the expression levels of key genes related to platelet function and PTM - associated pathways. CONCLUSION: By mapping the interplay between proteomic abundance shifts and PTM dynamics, this study provides a multidimensional understanding of PSL, establishing a foundational framework for optimizing storage protocols and enhancing transfusion safety.

Blood Platelets

Proteomics in environmental pollution research: Advances, challenges, and future directions.

Environmental proteomics has emerged as a powerful approach for elucidating the molecular mechanisms underlying pollutant-induced biological effects. Although this field has developed rapidly, the systematic review of recent proteomics applications in environmental pollution research remains limited. This review explored the emerging roles of toxicoproteomics in biomarker discovery and mechanistic elucidation, as well as ecotoxicoproteomics in ecological risk assessment and bioremediation strategies. Here, we review the field, highlighting recent trends such as the integration of proteomics with genomics, transcriptomics, and metabolomics to provide a comprehensive view of biological responses to environmental stressors. We further discuss the growing application of artificial intelligence in improving proteomics data interpretation and accelerating biomarker discovery. In addition, recent technological advances in environmental proteomics are highlighted, including next-generation tissue microarray proteomics, nanoscale proteomics, single-cell proteomics, and spatial proteomics. Despite its potential, proteomics faces challenges, such as high operational costs, computational complexity in analysis, and technical limitations in low-abundance protein detection. We propose that the convergence of proteomics with artificial intelligence and multi-omics approaches offers promising solutions to these challenges, enhancing the practical application of proteomics in environmental monitoring and risk assessment.

Proteomics

Proteomic characterization of the acquired enamel pellicle under acidic challenges at early and mature formation stages.

OBJECTIVES: This study aimed to characterize acquired enamel pellicle (AEP) proteomic changes after exposure to citric acid (CA) and hydrochloric acid (HCl) under different pellicle formation times (3 and 120&#x202f;min) in the same volunteers. DESIGN: Nine healthy volunteers participated in this randomized crossover in vivo study. The AEP was allowed to form for 3 or 120&#x202f;min and subsequently exposed for 10&#x202f;s to deionized water (control), 1% CA (pH 2.5), or 0.01&#x202f;M HCl (pH 2.0). Pellicle samples were collected, followed by protein extraction, tryptic digestion, and analysis by nanoliquid chromatography (nanoLC) coupled to mass spectrometry (MS) with MSE (data-independent acquisition; nanoLC-MS&#x1d31;). Label-free quantitative proteomics were performed for relative quantification using t-test (p&#x202f;<&#x202f;0.05). RESULTS: At 120&#x202f;min, CA exposure markedly reduced several typical AEP proteins, especially acidic proline-rich proteins (PRPs). Conversely, basic PRPs were upregulated, suggesting acid-resistance protein signature. At 3&#x202f;min, basal-layer proteins (PRPs, cystatins, histatins and mucins) were more abundant. Hemoglobins increased 6-8-fold (up to 150-fold in 3&#x202f;min control), suggesting association with early pellicle formation and an acid-resistant protein signature. CA exposures for 120&#x202f;min also upregulated typical AEP proteins (PRPs, mucins, cystatins, immunoglobulins), while HCl exposure depleted albumins and lactotransferrin. CONCLUSION: Intrinsic and extrinsic acids induce distinct proteomic signatures in the AEP. Hemoglobin and PRPs appear consistently enriched in the early pellicle layer, reflecting an initial acid-resistant protein signature. These findings provide new insights into the molecular remodeling of the AEP following intrinsic and extrinsic acid exposure, highlighting proteins potentially involved in early-stage pellicle formation.

Humans

Thermal analysis techniques for microplastic mass quantification: Methodological challenges and standardization needs.

Microplastics (MPs, 1 &#x3bc;m-5 mm) and nanoplastics (NPs, <1&#x202f;&#x3bc;m) are ubiquitous contaminants requiring standardized quantification methods. This systematic review evaluates thermal analysis techniques for mass-based MP detection, including pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS), thermogravimetry-MS (TGA-MS), thermal extraction desorption-GC-MS (TED-GC-MS), and differential scanning calorimetry (DSC). Database searches (Web of Science, from inception to December 1, 2025) following PRISMA guidelines identified studies across seven environmental matrices (water, soil/sediment, atmosphere, biota, human tissues). We identify critical standardization gaps: inconsistent marker ion selection, unvalidated conversion factors for tire and road wear particles (TRWPs), and the absence of certified reference materials for complex matrices. Py-GC-MS demonstrates versatility but suffers from lipid interference in biological samples; TED-GC-MS offers superior sensitivity (sample capacity &#x223c;200&#xd7; Py-GC-MS) but lacks real-time chromatographic monitoring. To advance data comparability, we propose: (i) harmonized ion selection hierarchies based on specificity-sensitivity balance, (ii) matrix-specific TRWP quantification protocols, and (iii) inter-laboratory validation using environmental reference materials. This review provides a methodological roadmap for standardizing thermal analysis in MP research.

Humans

Direct background subtraction LC-MS/MS assay for human plasma progesterone: Full validation and comparative application.

OBJECTIVE: To develop and validate a liquid chromatography-tandem mass spectrometry method based on direct background subtraction for the quantification of endogenous progesterone in human plasma. METHODS: Protein precipitation was used for sample preparation with deuterated progesterone as the internal standard. Chromatographic separation was performed on an ACQUITY C18 column using gradient elution with 0.1% formic acid in water and acetonitrile at a flow rate of 0.3&#xa0;mL/min. Mass spectrometry was operated in positive electrospray ionization mode with multiple reaction monitoring. Instead of using analyte-stripped matrix or surrogate matrix, authentic plasma was directly used for all validation experiments. Quantitation was achieved by subtracting the background signal, and results were compared with those from the classical method using stripped matrix. RESULTS: Excellent linearity was achieved over 0.1-100&#xa0;ng/mL (R2&#xa0;&#x2265;&#xa0;0.99). Precision, accuracy, recovery, matrix effect, and stability all met FDA and ICH M10 acceptance criteria. Compared with the classical method, the bias in Cmax and AUC0-t was within &#xb1;15%, indicating no significant difference between the two methods. CONCLUSION: The direct background subtraction method avoids laborious preparation of blank matrix, eliminates matrix effect discrepancies, and is simple, efficient, and low-cost. It can serve as a general strategy for endogenous substance determination.

Humans

Comprehensive study on pesticide residues and mycotoxins in freeze-dried strawberries and raspberries.

Freeze-dried fruit has gained popularity because it preserves the flavour and nutritional value of fresh fruit while providing extended shelf life. Despite this, there are concerns regarding its chemical safety. This study evaluated 58 freeze-dried fruit products from the Czech retail market, focusing on potential contamination. Pesticide residues and mycotoxins were determined using LC-MS/MS and GC-MS/MS. Overall, 111 pesticide residues (or their metabolites) and 3 mycotoxins were quantified. After applying processing factors, 12 pesticide residues exceeded EU maximum residue limits. Prohibited substances, including carbofuran, omethoate, and haloxyfop, were detected. Tenuazonic acid was found in 71% of samples, while alternariol and tentoxin were detected less frequently. More than half (54%) of strawberry samples contained 10 or more pesticide residues, indicating potential cumulative exposure concerns, particularly for children with lower body weight. These findings highlight the need for continued monitoring of freeze-dried fruits and further assessment of dietary exposure.

Pesticide Residues

Development and validation of a liquid chromatography-tandem mass spectrometry method for the quantification of twenty-five steroids in equine serum.

Steroids are potential biomarkers for monitoring equine pregnancy. However, immunoassays currently used for their quantification suffer from cross-reactivity and limited specificity, thus requiring more accurate methods. This study reports the development and validation of a robust liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous quantification of 25 steroids covering the main biosynthetic pathways of progestogens, corticosteroids, androgens, and estrogens. Steroids were extracted by protein precipitation followed by evaporation, derivatization, and reconstitution before LC-MS/MS analysis. A surrogate matrix was used for calibration and validation to avoid endogenous interference. Validation was performed according to and partly adapted from Clinical and Laboratory Standards Institute guidelines (CLSI), including linearity, trueness, precision, limits of detection and quantification, measurement uncertainty, recovery, matrix effects, carryover, selectivity, and stability. Calibration curves were fitted using the best-performing weighted linear or quadratic regression model, yielding excellent linearity (R2&#xa0;>&#xa0;0.990), trueness between -9.0% and 2.3%, and intra- and inter-day precision <6.3%. Lower limits of quantification ranged from 2.07 to 2250&#xa0;pg/mL depending on physiological analytes concentration. Extraction recovery averaged 24.3-114.9%, matrix effects were acceptable, and accuracy ranged from 94.4% to 98.9%. No carryover or interferences were detected. Measurement uncertainty remained <15%. This study presents the first LC-MS/MS method partially validated per CLSI criteria for the quantification of 24 steroids in equine serum. The method offers a sensitive and specific alternative to immunoassays and provides a robust tool for equine steroid profiling with potential applications in pregnancy monitoring, placentitis diagnosis, and fetal sex determination.

Animals

Effects of aerosol aging on composition and light-absorbance of nitrogen-containing organic compounds: Evidences from ultra-high-resolution mass spectrometry analysis.

Nitrogen-containing organic compounds (NOCs) are key components of particulate matter (PM), but their compositional evolution and light-absorbing properties during atmospheric aging remain poorly understood. In this study, ultra-high-performance liquid chromatography coupled with Orbitrap mass spectrometry was used to semi-quantitatively analyze 59 PM1 samples collected in Shanghai. NOCs accounted for 31 % and 64 % of the detected species in negative (ESI-) and positive (ESI+) ionization modes, respectively. Atmospheric aging significantly reduced the molecular diversity of polar organics, with both the number and mass concentration percentages of CHON- compounds showing significant negative correlations with aging degree. Van Krevelen analysis demonstrated a decrease in the number of carboxylic-rich alicyclic molecules and their CHON- contributions during the aging process (from 37.7 % in fresh samples to 21.2 % in aged samples). CHN+ compounds, a major NOCs group in ESI+ mode, also decreased with aging. Correlation analyses involving the Bep/(Bep+Bap) ratio, relative humidity, and mass absorption efficiency at 365 nm revealed a decline in light absorption capacity with aging, suggesting aqueous-phase oxidation as a dominant aging mechanism. CHON- and CHN+ compounds were identified as the principal light-absorbing constituents in PM1. This work provides new insights into the aging-induced transformations of NOCs in urban PM1, and their changing role in light absorption, highlighting the need for further investigation of the aging mechanisms of NOCs.

Aerosols

Unravelling bioanalytical innovations, degradation processes, and impurity landscapes of VEGFR inhibitors.

From pre-formulation studies to clinical trials, VEGFR-targeted small-molecule tyrosine kinase inhibitors (TKIs) require rigorous analytical standards. Bioanalysis, stability-indicating studies, and impurity profiling are used to examine chromatographic advances for VEGFR-targeted TKIs like sunitinib, pazopanib, axitinib, sorafenib, cabozantinib, vandetanib, apatinib, lenvatinib, nintedanib, and regorafenib. An LC-MS/MS and UPLC-MS/MS routinely show sub ng/mL performance, as shown by LLOQs (0.2&#xa0;ng/mL) for sunitinib and axitinib, 1&#xa0;ng/mL for pazopanib, 5-7&#xa0;ng/mL for sorafenib, 0.5-1.5&#xa0;ng/mL for regorafenib metabolic products, and 0.1-0.5&#xa0;ng/mL for lenvatinib. These approaches are used for pharmacokinetics and therapeutic drug monitoring due to their good correlation coefficient of 0.1-10,000&#xa0;ng/mL, accuracy of 95%-108%, and precision of 15% RSD. UPLC-QTOF-MS/MS distinguishes degradants and metabolites during forced degradation studies, enabling structural elucidation following ICH M7 risk evaluation protocol. HPTLC/MLC offers fast, sensitive screenings, while RP-HPLC/DAD or HPLC-UV offer reliable, cost-effective routine quality-control solutions with LOD/LOQ in the &#x3bc;g/mL range and linearity of 10-240&#xa0;&#x3bc;g/mL. This review lists the structures and CAS numbers of ten VEGFR-2 TKI degradants and metabolites, as well as pharmacopeial impurities in SMILES forms. It will be useful for future method development and regulatory applications. To ensure VEGFR-targeted TKI quality, safety, and therapeutic efficacy, LC-MS/MS for trace quantification and HRMS for structure elucidation provide a robust, future-oriented framework. To improve VEGFR-targeted TKI quality, safety, and regulatory compliance, analytical development should focus on HRMS-based impurity characterization, AI-assisted degradation prediction, green chromatography, and harmonized bioanalytical validation.

Humans

Furanic compounds in different coffee extraction systems: Analysis of the main influencing factors and correlation with acrylamide.

This study investigates how different coffee types representative of distinct roast profiles and brewing methods jointly affect the occurrence of furanic compounds and acrylamide in brewed coffee. Coffees were prepared using eight extraction methods (AeroPress, Clever, Chemex, French Press, Moka, Pure Brew, Turkish and V60). Five furanic compounds (furfural, furfuryl acetate, 5-methylfurfural, furfuryl alcohol and 5-hydroxymethylfurfural) were quantified in coffee powders and brews by HS-SPME-GC-MS, while acrylamide was determined by UHPLC-MS/MS. Moka and Turkish brews consistently exhibited the highest concentrations of furanic compounds, whereas paper-filtered pour-over methods (V60 and Chemex) showed the lowest levels. Pearson correlation analysis revealed coffee-dependent relationships between furanic compounds, acrylamide and extraction parameters with the strongest associations observed in dark-roasted coffee, reflecting advanced Maillard reaction chemistry. Overall, these results demonstrate that contaminant levels arise from the combined effects of intrinsic coffee chemistry and brewing mechanics and support targeted mitigation strategies: such as roast selection and brewing method optimization.

Acrylamide

Development and validation of a novel LC-MS/MS method for simultaneous quantification of fidaxomicin and metabolite (OP-1118) from feces for gut pharmacobiome studies.

Fidaxomicin is a first-line antibiotic for treating Clostridioides difficile infection. While it has low systemic absorption and reaches high colonic concentrations, it is hydrolyzed to a less active metabolite, OP-1118. Few studies have completely described critical experimental details of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for quantifying fecal fidaxomicin and OP-1118. This study developed and validated a simple, fast, and sensitive LC-MS/MS method to quantify fidaxomicin and OP-1118 in human and mouse feces. This method simplified fecal sample preparation without the use of solid phase extraction and optimized LC-MS/MS parameters. A broad working range (0.3-1000&#xa0;ng/ml) in both diluted human and murine fecal matrices was achieved with good intra- and inter-day accuracy (93-107%), precision (1-7%), and recovery (70-105%) as well as little IS-normalized matrix effects. This method was utilized to quantify fidaxomicin and OP-1118 in human and murine fecal samples. This novel method was simple, fast, sensitive, and accurate in analyzing fecal fidaxomicin and OP-1118 and could be deployed to facilitate gut pharmacobiome research.

Feces

Validated UPLC-MS/MS quantification and intracellular PK-PD Modeling of periplocin-related cardiac glycosides in H/R-injured H9c2 cells.

Reliable intracellular quantification is essential for characterizing the target-site disposition and exposure-response relationships of bioactive natural products. In this study, an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the simultaneous determination of periplocin and four related cardiac glycoside metabolites in H9c2 cell lysates. Acceptable linearity, precision, recovery, and stability were achieved for intracellular quantification. Cells were treated with each compound at 50&#xa0;&#x3bc;M, and intracellular concentrations and cell viability were monitored over 48&#xa0;h. In hypoxia/reoxygenation (H/R) -injured cells, the time to maximum intracellular concentration was shortened for all five compounds, indicating altered cellular disposition under injury conditions. Cell viability was improved by all compounds during the observation period. Pharmacokinetic-pharmacodynamic (PK-PD) integration was performed using a sigmoid Emax model, and acceptable model fits were obtained, with Akaike information criterion (AIC) values ranging from 79.22 to 130.46. Low apparent EC50 values were estimated under this single-dose design, whereas the estimated Ke0 values suggested delayed equilibration with the effect compartment. These findings indicate that sustained cytoprotective responses can be produced by periplocin and related metabolic markers in injured cardiomyocytes. This intracellular bioanalytical strategy provides a quantitative approach for linking cellular exposure to pharmacodynamic response and may support further evaluation of periplocin-related cardiac glycosides.

Tandem Mass Spectrometry

Quantifying the aromatic amino acid metabolome: UPLC-MS/MS analysis of aromatic amino acids and their host and co-metabolites in plasma.

Aromatic amino acids (AAAs), tryptophan, phenylalanine, and tyrosine along with their pathway metabolites have been implicated in the pathogenesis of diseases ranging from cardiovascular, neurological, inflammatory, and cancer diseases, among others. As such, the measurement of the primary AAAs, their host pathway metabolites, and microbiome derived co-metabolites in blood can provide a sensitive reflection of systemic health. The aim of the study was to develop a method for the quantification of 17 metabolites, the three AAAs and various of their metabolites in plasma using a high-throughput ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method. The method demonstrated a dynamic range (1 to 16,700&#xa0;ng/mL), with detection limits (LOD) as low as 0.05&#xa0;ng/mL. Quantification limits ranged from 3 to 5019&#xa0;ng/mL (LLOQ) and up to 16,700&#xa0;ng/mL (ULOQ). Recovery at LQC, MQC, and HQC was satisfactory and consistent across most metabolites, with significant matrix effects observed only for 4-ethylphenol sulfate. Furthermore, intra and inter-day accuracy and precision met all acceptance criteria at all quality control concentrations for most of the metabolites. Measurement of NIST SRM 1950 showcased the method's accuracy for most of the metabolites. Finally, the method was applied on the analysis of plasma samples from 55 individuals (13 males and 42 females) providing information on AAAs and their pathway metabolites relevant concentrations in human plasma.

Amino Acids, Aromatic

Improved comprehensive profiling of fecal bile acids through chemical derivatization combined with HPLC-MS/MS analysis.

Bile acids (BAs) facilitate the digestion and absorption of fats and influence lipid and glucose homeostasis, making them potential therapeutic targets for obesity and related metabolic disorders. The liver and intestinal microbiota modify BAs structurally, generating diverse chemical forms and isomers. Comprehensive profiling of the BA pool is critical for understanding their key biological functions and as a therapeutic approach for related diseases. High-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) is usually chosen as the preferred method for BA detection due to the complex chemical structures, the wide range of actual concentrations and the complexity of fecal sample matrices. However, free BAs are difficult to ionize, resulting in low detection signals and a lack of characteristic structural fragments to assist in structural identification. In this method, the labeling reagent (2-aminoethyl) trimethylammonium (AETMA) is employed to label the carboxyl group of BAs. Compared with underivatized BAs, the detection sensitivity of unconjugated BAs was enhanced by 25-180 fold, while that of conjugated BAs increased by 6-160 fold. It also generates unique fragment ions and enhances MS response, facilitating the discovery of potential BAs. Methodological parameters were validated using 38 BAs as representatives. Through methodological validation, it was verified that the precision, recovery, matrix effect and stability parameters of the method met acceptable criteria. We also identified 61 confirmed BAs and 55 additional candidate BAs in human pooled fecal samples. It has been successfully applied to fecal BA analysis in obese populations, providing valuable insights into potential therapeutic strategies for obesity.

Tandem Mass Spectrometry

A validated sensitive LC-MS/MS method and its application in elucidating the unique ocular pharmacokinetic profile of 0.01% atropine underpinning its clinical utility for myopia.

A sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated to quantify atropine in ten rabbit ocular tissues enabling systematic characterization of the ocular pharmacokinetic profile of 0.01% atropine sulfate eye drops after a single topical administration. The method demonstrated excellent linearity (coefficient of determination, R2&#xa0;&#x2265;&#xa0;0.9908) across all matrices, with lower limits of quantification (LLOQ) of 0.05&#xa0;ng/mL for most tissues and 0.10&#xa0;ng/mL for retina and lens; intra- and inter-day accuracy, precision, matrix effects, extraction recoveries, and stability all met the acceptance criteria. Following a single bilateral topical dose (50&#xa0;&#x3bc;L/eye) in New Zealand White rabbits, atropine distributed rapidly into all 12 ocular compartments (the sclera further divided into three anatomical regions) with marked heterogeneity-the highest exposures were found in conjunctiva and cornea, a distinct anterior-to-posterior concentration gradient was observed in the sclera, sustained retention was noted in the retina (mean residence time from zero to the last measurable time point, MRT0-t 3.30&#xa0;h), while aqueous and vitreous humor eliminated rapidly (elimination half-life, t&#x2081;/&#x2082;&#xa0;<&#xa0;0.7&#xa0;h), and all tissues except aqueous humor followed a two-compartment model. This validated method and the comprehensive pharmacokinetic data reveal that topically applied 0.01% atropine achieves sustained exposure in key myopia-regulating tissues (retina, choroid, posterior sclera) with low exposure in side-effect target tissues (iris, ciliary body, lens).

Animals

Development and validation of an LC-MS/MS method for the quantification of the KRASG12C inhibitor divarasib.

Divarasib is a newly developed covalent KRASG12C inhibitor, currently under clinical investigation in a phase 3 trial in patients with non-small cell lung cancer (NSCLC). At the moment, very limited pharmacokinetic data are publicly known. However, obtaining more insight into the pharmacokinetic properties of divarasib is important, since this may provide a better understanding of its efficacy and safety risks. Pre-clinical studies have been performed in mouse models to evaluate the effect of drug transporters and drug-metabolizing enzymes on the plasma exposure and tissue distribution of divarasib. Therefore, a reliable quantification method is required. To our knowledge, no bioanalytical assay of divarasib has been published yet. Therefore, in this study we developed and validated an assay to quantify divarasib in human plasma and in eight different mouse-related matrices, and partially in mouse plasma, using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method was initially evaluated over a concentration range of 1-10,000&#xa0;nM. However, due to carry-over observed at 10,000&#xa0;nM, the validated calibration range was established at 1-2000&#xa0;nM, with matrix-dependent LLOQs of 1-10&#xa0;nM. Erlotinib was used as an internal standard and acetonitrile was utilized to perform protein precipitation as sample pretreatment. Divarasib demonstrated stability in human plasma and in mouse plasma and tissue homogenates under various experimental conditions. A pilot in vivo study showed the applicability of our validated LC-MS/MS method. Ongoing clinical trials may collect plasma samples, and this developed method enables quantification of divarasib in both mouse and human plasma samples.

Animals