Search PubMedSearch

SEARCH · Search PubMed

Results for “high-sensitivity imaging”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,027 recordsLinked to original sources

An automated geometric modeling framework in GATE for the design and optimization of high-sensitivity converging-beam SPECT collimators.

Objective.The trade-off between detection sensitivity and spatial resolution is a fundamental challenge in designing organ-dedicated Single-photon emission computed tomography (SPECT) collimators. While converging-hole geometries offer a solution, their optimization is often hindered by the lack of flexible computational tools capable of modeling large-scale, non-parallel hole arrays. This study aims to develop an automated geometric modeling framework to facilitate the design and evaluation of complex converging- and diverging-hole collimators within standard Monte Carlo environments.Approach.We developed a specialized modeling framework by implementing custom C++ classes and a vector-based alignment algorithm within GATE. This platform enables automated, orientation-consistent construction of large-scale converging arrays not natively supported by standard implementations. A high-sensitivity pure cone-beam collimator (CBC) was designed using this framework. The evaluation used hot-rod, disc, and Jaszczak phantoms for physical characterization, while XCAT and dedicated brain models were employed for clinical tasks, including cardiac, brain perfusion, and DaTscan SPECT simulations.Main results.The CBC achieved a nearly fourfold sensitivity increase compared to a conventional low-energy high-resolution parallel-hole collimator at a 20 cm radius of rotation, while maintaining comparable spatial resolution. Despite a 52.3% field of view reduction, the CBC yielded a 2.2-fold noise reduction (CV: 11.7% vs 25.9%) and mitigated partial volume effects via geometric magnification. XCAT and brain phantom simulations confirmed enhanced anatomical definition and contrast recovery in cardiac, perfusion, and DaTscan tasks.Significance.This work provides an efficient computational tool for rapid design space exploration of advanced collimator geometries. The results demonstrate that the proposed CBC design offers a significant sensitivity advantage, making it highly suitable for high-performance, small-volume clinical applications such as brain and cardiac molecular imaging.

Tomography, Emission-Computed, Single-Photon

Enhanced fracture detection on radiographs with AI assistance for clinicians: a systematic review and meta-analysis.

BACKGROUND: Emergency radiographic interpretation for fractures is prone to missed or misdiagnoses. Artificial intelligence (AI) is expected to become a powerful tool to assist clinicians in fracture detection. PURPOSE: A systematic review and meta-analysis was performed to assess whether AI improves clinicians' ability to detect fractures on radiographs. MATERIALS AND METHODS: A literature search was conducted in PubMed, Web of Science, and Cochrane Library for studies published between January 1, 2010, and October 10, 2025. A meta-analysis of diagnostic accuracy studies was performed using a Summary Receiver Operating Characteristic (SROC) curve. The quality of included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Subgroup analysis and meta-regression were conducted to explore potential sources of heterogeneity. RESULTS: A total of 26 studies were included . The pooled sensitivity of clinicians increased from 77% (95% CI: 72-81) to 87% (95% CI: 83-90) with AI assistance, while the pooled specificity improved from 88% (95% CI: 85-90) to 92% (95% CI: 89-94). The corresponding AUC values were 0.90 (95% CI: 0.87-0.92) before and 0.95 (95% CI: 0.93-0.97) after AI assistance. Eight studies were rated as high risk of bias. Subgroup analysis and meta-regression identified potential sources of heterogeneity, including fracture location, AI model type, high risk of bias, and reference standards. CONCLUSION: AI assistance significantly improves clinicians' diagnostic performance in detecting fractures on radiographs for extremity and trunk fractures.

Humans

AI-driven snapshot hyperspectral imaging for on-line sorting systems in food industry: From real-time sensing to intelligent decision-making.

High-throughput food sorting requires rapid, non-destructive detection of external defects, foreign materials, and internal quality attributes in heterogeneous food matrices. Conventional scanning hyperspectral imaging may suffer from motion-induced spatial-spectral mismatches, whereas snapshot hyperspectral imaging (S-HSI) captures spectral images within a single integration time. However, its advantage is limited by trade-offs in resolution, signal-to-noise ratio (SNR), reconstruction uncertainty, and calibration stability, which are further amplified by variable tissue structure, surface reflection, moisture, and fat distribution in foods. This review critically examines artificial intelligence (AI)-driven S-HSI for on-line food sorting within a sensing-representation-decision-execution framework. Compact architectures are compared according to their physical constraints, food-sorting suitability, and ability to support mapping between spectral responses and physicochemical quality attributes. AI strategies are reviewed for spectral reconstruction, image restoration, spatial-spectral representation, band selection, uncertainty-aware decision-making, and edge implementation. AI can partially compensate for snapshot-specific limitations, but current evidence remains largely limited to laboratory or prototype studies. Future work should link system performance to food safety and quality outcomes by reporting throughput, decision latency, calibration drift, missed-detection risk, false-rejection cost, and closed-loop sorting success.

Hyperspectral Imaging

Artificial intelligence for dental caries detection: An umbrella review.

Artificial intelligence (AI) has been proposed as a tool to improve dental caries detection across imaging modalities; however, its clinical value remains uncertain. This umbrella review aimed to synthesize and critically appraise systematic reviews evaluating AI for caries detection and diagnosis. An umbrella review was conducted following PRIOR guidance (PROSPERO CRD420261340728). Searches were performed in MEDLINE, Embase, Scopus, Web of Science, and Google Scholar up to 15 March 2026. Methodological quality was assessed using AMSTAR 2, and overlap of primary studies was quantified using the corrected covered area (CCA). Seventeen systematic reviews were included, of which five reported diagnostic test accuracy meta-analyses using bivariate or HSROC models. Across these meta-analyses, pooled sensitivity ranged from 0.76 to 0.94 and specificity from 0.85 to 0.91. Most systems were based on deep learning models applied to bitewing radiographs and intraoral photographs. However, substantial heterogeneity was observed in imaging modalities, lesion thresholds, analytical tasks, and evaluation metrics. In addition, a high degree of overlap across reviews and recurrent methodological limitations, including reliance on retrospective datasets, limited external validation, and inconsistent reporting, substantially weaken the reliability of the evidence. Although AI models demonstrate high diagnostic performance under experimental conditions, current evidence does not support their use as stand-alone diagnostic tools. Their clinical applicability remains limited, and implementation should be restricted to decision-support contexts until robust prospective validation demonstrates meaningful impact on clinical decision-making and patient outcomes.

Dental Caries

Repeated scoring with the adult appendicitis score improves the sensitivity and the specificity of appendicitis diagnosis in patients with early equivocal signs of appendicitis: a secondary analysis.

PURPOSE: The utilization of computed tomography in the early stage of acute appendicitis may result in overdiagnosis and unnecessarily expose patients to ionising radiation. The Adult Appendicitis Score (AAS) can be used to select patients for imaging. Observation and re-scoring in the DIAMOND trial reduced the need for imaging. Now, we wanted to determine if the change in AAS (∆AAS) can serve as a diagnostic tool to select patients for imaging even more precisely. METHODS: Eighty-eight patients with early equivocal appendicitis participated in the observation arm of the DIAMOND trial. The data for these patients were reanalysed, and ∆AAS during the observation was calculated. The baseline AAS, final AAS, and the change in C-reactive protein (∆CRP) were selected as reference standards. RESULTS: Eighty-three patients with complete data were included in the analysis. The AUROC (Area Under the Receiver Operating Characteristic) values are as follows: ∆AAS, 0.932 (95% CI 0.868-0.996); baseline AAS, 0.629 (95% CI 0.498-0.760); final AAS, 0.936 (95% CI 0.886-0.987); and ∆CRP, 0.796 (95% CI 0.696-0.897). Using receiver operating characteristic curves, we established the thresholds for low (AAS ≤ -2), intermediate (AAS -1 to 0), and high (AAS ≥ 1) probability of appendicitis. The negative predictive value for the low-probability group and the positive predictive value for the high-probability group concerning acute appendicitis were 97% and 94%, respectively. CONCLUSION: Patients with equivocal signs of appendicitis may benefit from short observation and the calculation of ∆AAS to reduce overdiagnosis and exposure to excessive imaging. REGISTRATION: The DIAMOND trial was officially registered on ClinicalTrials.gov (NCT02742402) on April 13, 2016.

Adult

Efficacy of current approaches to non-invasive diagnosis of skin cancer and the potential impact of artificial intelligence: A systematic review and meta-analysis.

BACKGROUND: Skin cancer is one of the most prevalent malignancies worldwide, particularly within Caucasian populations. This systematic review and meta-analysis aimed to quantitatively review the current literature on non-invasive diagnosis of skin cancer and evaluate the current evidence to support the use of tools in addition to, or in replacement of clinician face-to-face assessment. METHODS: A literature search was conducted for publications in PubMed, Medline and Embase databases. Articles describing accuracy, sensitivity, specificity and outcomes of their mode of assessment were included. A total of 208 articles met the inclusion criteria. RESULTS AND CONCLUSION: This systematic review and meta-analysis showed that the diagnostic performance of artificial intelligence (AI) in the interpretation of dermatoscopic images was high for melanoma diagnosis, basal cell carcinoma or malignancy, in comparison to dermatoscopic assessment alone by clinicians and experts. Although AI interpretation of images demonstrated higher sensitivity for melanoma diagnosis in comparison to clinical assessment combined with dermatoscopic assessment, it is unclear if this is also the case for basal cell carcinoma and squamous cell carcinoma diagnosis. Reflectance confocal microscopy, a non-invasive high resolution imaging technique, is known to have a high sensitivity for diagnosing cutaneous malignancy, and this may have applications within secondary care. Therefore, AI could help reduce resource burden and aid in clinical assessment, particularly within primary care settings.

Humans

Diagnostic criteria and severity assessment for syndesmosis injury using magnetic resonance imaging: A systematic review.

High ankle sprains involving syndesmosis injury present challenges in both diagnosis and severity assessment. Magnetic resonance imaging is widely regarded as the preferred modality for evaluating syndesmosis injury and related structural damage. This systematic review primarily examined the diagnostic utility of magnetic resonance imaging. Secondarily, it explores grading and prognostics of syndesmosis injuries with magnetic resonance imaging and identified possible imaging parameters predictive of injury severity. A comprehensive search of MEDLINE, Embase, CINAHL Complete, and Scopus was performed through February 12, 2025, following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Peer-reviewed human studies in English that used magnetic resonance imaging to assess syndesmosis injury were included. Excluded were review articles, case reports, abstract-only studies, and biomechanical or cadaveric investigations. Twenty-seven studies comprising 1931 ankles met inclusion criteria. Magnetic resonance imaging demonstrated high diagnostic accuracy for complete tears of the anterior and posterior inferior tibiofibular ligaments. Ancillary signs such as the ring-of-fire edema pattern, distal tibiofibular joint effusion, and widening of the distal joint space exhibited high specificity with variable sensitivity and may assist in grading injury severity. Magnetic resonance imaging in chronic syndesmosis injury primarily detects fibrotic scarring and post-injury changes. Evidence gaps remain regarding the parameters that best determine injury severity and indicate early surgical intervention in competitive athletes. Consolidating multiple magnetic resonance imaging findings into standardized diagnostic criteria may improve reliability and clinical decision-making.

Humans

Combining neuromelanin-sensitive MRI and quantitative susceptibility mapping for enhanced diagnosis and differentiation of parkinson's disease: A systematic review.

BACKGROUND: Loss of dopaminergic neurones and iron deposition in the substantia nigra pars compacta (SNpc) are two major pathological hallmarks of Parkinson's disease (PD). Such changes can be visualised by advanced techniques including neuromelanin-sensitive MRI (NM-MRI) and quantitative susceptibility mapping (QSM). This systematic review investigates the diagnostic performance and methodological development of the integrated use of NM-MRI and QSM in PD. METHODS: The systematic search was performed in four databases (Scopus, PubMed, ScienceDirect, and Web of Science) according to the PRISMA 2020 guidelines until July 2026. Bias was assessed using QUADAS-2 and certainty of evidence was assessed using GRADE. RESULTS: Seventeen studies with 2228 participants were included. Combined NM-MRI and QSM consistently showed reduced neuromelanin volume/contrast and increased iron deposition in the SNpc of PD patients compared to healthy controls. Multimodal integration yielded a significant improvement in diagnostic accuracy (AUC values 0.86-0.99), and was able to successfully differentiate PD. Recent methodological advances included simultaneous acquisition sequences (e.g. MTC-GRE, STAGE, setMag) and AI-driven automated segmentation, which led to significantly reduced scan times and improved reproducibility. CONCLUSION: The combination of NM-MRI and QSM has a synergistic effect and provides powerful complementary biomarkers for the diagnosis and differential diagnosis of PD.

Humans

Artificial Intelligence for Diagnosing Meibomian Gland Dysfunction: A Systematic Review and Meta-Analysis of Diagnostic Test Accuracy Studies.

PURPOSE: To identify, appraise, and synthesize the performance of artificial intelligence-based meibography reading as compared with human graders in diagnosing meibomian gland dysfunction. METHODS: We followed Cochrane methodology and reporting guidelines for diagnostic test accuracy reviews. To assess potential risk of bias and applicability, we used a modified Quality Assessment of Diagnostic Accuracy Studies-2 checklist. We applied bivariate logistic models to estimate summary sensitivity and specificity when appropriate and used the GRADE framework to rate the certainty of the evidence. RESULTS: We identified 14 eligible studies involving 5511 predominantly middle-aged participants (average age: 27-55 years) who were primarily female (≥54.5%). A total of 18,926 meibography images were obtained through noncontact infrared (11 studies) or in vivo confocal microscopy (three studies). Two studies reported external validation of deep learning models, 12 reported internally validated models, and one reported both. All but one study had high risk of bias in at least one domain; 12 studies raised high or intermediate concern about applicability. Based on three external evaluations, the summary sensitivity and specificity for diagnosing meibomian gland dysfunction from normal glands were 97.5% (95% confidence interval: 77.5%-99.8%) and 85.5% (95% confidence interval: 47.3%-97.5%). Sources of heterogeneity in internally validated models included study population, case mix, and others. The overall evidence was very low to low certainty because of imprecision, high risk of bias, and concerns about applicability. CONCLUSIONS: Artificial intelligence-based meibography grading appears less accurate than human graders. Future studies should adopt rigorous designs, including a more diverse participant pool (or image set), and external validation.

Humans

Quantitative susceptibility mapping in neurodegenerative diseases: An umbrella review of iron-related biomarkers and mechanisms.

Pathological iron accumulation is a common pathophysiological hallmark across multiple neurodegenerative diseases (NDDs), motivating the need for accurate, non-invasive quantification methods. Quantitative susceptibility mapping (QSM) is an advanced magnetic resonance imaging (MRI) technique that enables in vivo measurement of tissue magnetic susceptibility (χ), providing a sensitive proxy for iron content. This umbrella review systematically evaluates the diagnostic accuracy, clinical correlations, and distinct iron distribution patterns of QSM in major NDDs, such as Parkinson's disease (PD), Alzheimer's disease (AD), amyotrophic lateral sclerosis (ALS), and atypical Parkinsonism. We included 15 (13/15 were rated Low or Critically Low on AMSTAR 2) systematic reviews and meta-analyses (through July 15, 2026); however, the findings should be interpreted cautiously because of heterogeneity and the low methodological quality. A Corrected Covered Area (CCA) analysis demonstrated only slight overlap of primary studies across the included reviews (CCA = 5.42%). Collectively, the evidence indicates that QSM provides comparable or higher diagnostic sensitivity and reliability than conventional R2* and SWI techniques, particularly for deep gray matter structures. The findings support significant iron overload in the substantia nigra, particularly in the pars compacta, as a robust biomarker for PD that correlates with motor severity and disease duration. Furthermore, regional iron profiling in the basal ganglia is critical for differential diagnosis; specifically, elevated χ in the putamen and globus pallidus effectively distinguishes multiple system atrophy and progressive supranuclear palsy from idiopathic PD. Distinctively, AD and ALS exhibit specific χ alterations in the thalamus, motor cortex, and hippocampus, reflecting divergent iron-related pathophysiological mechanisms, which correlate with cognitive impairment and upper motor neuron signs. Overall, QSM shows diagnostic promise and offers mechanistic insights into iron-related neurodegenerative processes.

Humans

Prevalence of Slowly Expanding Lesions in Patients With Multiple Sclerosis: A Systematic Review and Meta-Analysis.

BACKGROUND AND OBJECTIVES: Chronic active lesions (CALs) reflect chronic inflammation in multiple sclerosis (MS). Slowly expanding lesions (SELs) are CALs identified on conventional MRI by linear, concentric expansion over time, while paramagnetic rim lesions (PRLs) are CALs characterized by a paramagnetic rim on susceptibility-sensitive MRI. However, the prevalence of SELs and their overlap with PRLs remain unclear. The aims of this study were to (1) estimate the proportion of SELs among all T2 lesions and the proportion of patients with at least 1 SEL and (2) assess the proportion of SELs overlapping with PRLs. METHODS: We systematically searched PubMed, Scopus, Web of Science, and Embase on February 1, 2026, for studies evaluating SELs in MS. At least 2 authors independently assessed study eligibility. Primary outcomes were the pooled proportion of SELs among T2 lesions and the proportion of patients with at least 1 SEL. We estimated mean per-patient volumes of SELs and total T2 lesions and the proportion of SELs overlapping with PRLs. Random-effects generalized linear mixed-effects models and inverse-variance methods were used, with between-study heterogeneity assessed using τ2 and I2 and robustness using sensitivity analyses. Univariable meta-regression explored heterogeneity. PROSPERO: CRD42024603778. RESULTS: Of 5,980 records, 20 studies comprising 4,786 patients with MS were included (mean age: 43.6 ± 6.3 years; 63.7% female). Sample sizes varied by outcome. SELs accounted for 14% (95% CI 10-21) of all T2 lesions, and 78% (67-85) of patients had at least 1 SEL. After sensitivity analysis, per-patient mean volumes were 1.42 mL (0.79-2.06) for SELs and 10.6 mL (8.53-12.67) for total T2 lesions. In total, 11% (6-20) of SELs overlapped with PRLs. In subgroup analyses, proportions of SELs were similar in relapsing-remitting and progressive MS (15%), but the proportion of patients with at least 1 SEL was higher in progressive MS. Between-study heterogeneity was high across analyses with no significant sources identified. DISCUSSION: Although SELs represent a minority of T2 lesions, most patients have at least 1 SEL and a subset overlaps with PRLs, suggesting a partial correspondence between these 2 imaging markers of chronic inflammatory activity. Limitations include possible publication bias, high unexplained heterogeneity, differences in SEL identification methods, and differences in MRI time point number/timing.

Humans

The Role of Artificial Intelligence Combined With Digital Cholangioscopy for Indeterminant and Malignant Biliary Strictures: A Systematic Review and Meta-analysis.

BACKGROUND: Current endoscopic retrograde cholangiopancreatography (ERCP) and cholangioscopic-based diagnostic sampling for indeterminant biliary strictures remain suboptimal. Artificial intelligence (AI)-based algorithms by means of computer vision in machine learning have been applied to cholangioscopy in an effort to improve diagnostic yield. The aim of this study was to perform a systematic review and meta-analysis to evaluate the diagnostic performance of AI-based diagnostic performance of AI-associated cholangioscopic diagnosis of indeterminant or malignant biliary strictures. METHODS: Individualized searches were developed in accordance with PRISMA and MOOSE guidelines, and meta-analysis according to Cochrane Diagnostic Test Accuracy working group methodology. A bivariate model was used to compute pooled sensitivity and specificity, likelihood ratio, diagnostic odds ratio, and summary receiver operating characteristics curve (SROC). RESULTS: Five studies (n=675 lesions; a total of 2,685,674 cholangioscopic images) were included. All but one study analyzed a deep learning AI-based system using a convoluted neural network (CNN) with an average image processing speed of 30 to 60 frames per second. The pooled sensitivity and specificity were 95% (95% CI: 85-98) and 88% (95% CI: 76-94), with a diagnostic accuracy (SROC) of 97% (95% CI: 95-98). Sensitivity analysis of CNN studies (4 studies, 538 patients) demonstrated a pooled sensitivity, specificity, and accuracy (SROC) of 95% (95% CI: 82-99), 88% (95% CI: 72-95), and 97% (95% CI: 95-98), respectively. CONCLUSIONS: Artificial intelligence-based machine learning of cholangioscopy images appears to be a promising modality for the diagnosis of indeterminant and malignant biliary strictures.

Humans

Mitigating pH-induced instability in deruxtecan-based ADCs: an onboard-mixing icIEF approach for robust charge heterogeneity characterization.

Accurate charge variant analysis of antibody-drug conjugates (ADCs) is essential for understanding product heterogeneity and ensuring quality control. However, Deruxtecan (DXd)-based ADCs present a unique analytical challenge due to the intrinsic instability of the payload, where the lactone ring readily undergoes hydrolysis under alkaline conditions, resulting in time-dependent shifts in charge distribution during imaged capillary isoelectric focusing (icIEF). In this study, we describe the development of an onboard-mixing icIEF method designed to minimize pH-induced degradation during sample preparation. By separating ADC samples from carrier ampholytes (CAs) prior to injection and enabling real-time mixing within the instrument, this approach effectively suppresses premature lactone ring opening and stabilizes charge variant profiles. Comparative studies between conventional premixing and onboard-mixing approach demonstrated that the latter significantly enhances reproducibility, particularly for acidic variants that are highly sensitive to structural conversion. Comprehensive method validation confirmed excellent precision, linearity, and sensitivity, with consistent performance across run-to-run and intra-day analyses. The results underscore the importance of controlling microenvironmental pH exposure in the analysis of chemically instable ADCs. The proposed onboard-mixing strategy provides a robust and efficient solution for icIEF-based characterization, reducing analytical artifacts while simplifying method development. This approach is broadly applicable to ADCs and other biotherapeutics containing pH-sensitive functional groups.

Hydrogen-Ion Concentration

Development and Crossover Evaluation of an Artificial Intelligence-Assisted System for Solid Pancreatic Lesion Detection and Pancreatic Parenchyma Recognition in Endoscopic Ultrasonography (With Video).

BACKGROUND AND STUDY AIMS: Pancreatobiliary endoscopic ultrasonography (EUS) is technically demanding, and supervised training opportunities are limited. We developed an artificial intelligence (AI) overlay system for detecting solid pancreatic lesions (SPL) and recognizing pancreatic parenchyma (PP) and evaluated its effect on reader performance. PATIENTS AND METHODS: Across six centers, two deep learning-based models were trained using expert-annotated EUS frames. We then conducted a randomized, two-sequence, two-period crossover reader study in which eight endosonographers (five novices and three experts) interpreted image sets with and without AI assistance. The primary endpoint was superiority of sensitivity for SPL detection among novices; key secondary endpoints included specificity and PP recognition. RESULTS: From 118 patients, 120 SPL-positive/negative image sets and 160 PP-positive/negative image sets were constructed. Among novices, AI assistance improved SPL detection sensitivity (88.7% vs. 76.8%, p&#x2009;<&#x2009;0.001) and accuracy (86.4% vs. 78.7%), while specificity met the predefined noninferiority criterion (84.2% vs. 80.5%, p&#x2009;<&#x2009;0.001). For PP recognition, sensitivity increased numerically (86.3% vs. 83.3%) but did not meet the predefined superiority criterion (p&#x2009;=&#x2009;0.095); specificity met the noninferiority criterion (87.8% vs. 81.0%), and accuracy increased from 82.1% to 87.0%. Among experts, sensitivity was maintained for both tasks, whereas specificity increased with AI assistance. CONCLUSIONS: AI assistance improved SPL detection among novice endosonographers. For PP recognition, sensitivity increased without reaching statistical superiority, whereas specificity met the predefined noninferiority criterion. These findings support a potential adjunctive role for AI in EUS interpretation.

Humans

Diagnostic performance of intraoperative in vivo hyperspectral imaging for meningioma grading and molecular alterations: results from a prospective feasibility study.

OBJECTIVE: Hyperspectral imaging (HSI) is an emerging intraoperative, noninvasive, contrast agent-free imaging modality that enables quantitative assessment of tissue composition. The present study aimed to investigate whether HSI-derived tissue parameters correlate with WHO grade and molecular markers of aggressiveness in cranial meningiomas. METHODS: In this prospective study, intraoperative in vivo HSI was performed using the TIVITA tissue system, capturing spectral signatures between 500 and 1000 nm. Quantitative tissue parameters included tissue oxygen saturation (StO2), near-infrared perfusion index, organ hemoglobin index (OHI), and tissue water index (TWI). HSI parameters were correlated with histopathological WHO grade and molecular alterations, including CDKN2A/B deletion, TERT promoter mutation, and 1p/22q loss. Group differences were analyzed using one-way ANOVA, and diagnostic performance was assessed using receiver operating characteristic (ROC) analysis. RESULTS: Forty-six meningiomas were included, comprising WHO grade 1 (n = 35) and WHO grade 2-3 (n = 11) tumors. TWI was significantly higher in WHO grade 2-3 meningiomas compared with WHO grade 1 tumors (mean 0.49 [SD 0.12] vs 0.38 [SD 0.17], p = 0.048). ROC analysis demonstrated an area under the ROC curve (AUC) of 0.71 (95% CI 0.56-0.86, p = 0.036) for TWI in discriminating higher-grade disease. A TWI cutoff &#x2265; 0.367 identified all WHO grade 2-3 meningiomas with 100% sensitivity and 100% negative predictive value. In a molecular subgroup (n = 15), OHI appeared higher in tumors with homozygous CDKN2A/B deletion than in nondeleted tumors (mean 0.77 [SD 0.04] vs 0.62 [SD 0.10]). However, only 3 CDKN2A/B-deleted cases were available, and these findings should be considered descriptive. ROC analysis yielded an AUC of 0.89 (95% CI 0.71-1.00). An OHI cutoff &#x2265; 0.712 identified all three CDKN2A/B-deleted tumors (100% sensitivity), with 83.3% specificity and 86.7% accuracy. CONCLUSIONS: The present investigation demonstrated that HSI-derived tissue water and hemoglobin metrics provide biologically meaningful information in meningiomas. Low tissue water content appeared to rule out higher-grade diseases in this first subset cohort, while elevated hemoglobin showed a potential association with CDKN2A/B deletion in a small exploratory subgroup. These findings support the potential of HSI as a real-time noninvasive tool for intraoperative risk stratification and should be evaluated in large-scale studies. German Clinical Trials Register no. DRKS00036771 (www.drks.de).

Humans

Artificial intelligence-supported double reading in European population breast cancer screening: A systematic review and meta-analysis of prospective programs.

BACKGROUND: Most European population mammography screening programs rely on double reading with arbitration, a model that delivers mortality benefit but is increasingly challenged by radiologist workload, variable specificity, and interval cancers. Artificial intelligence (AI) is being evaluated to support or optimize these established European screening pathways. PURPOSE: To synthesize prospective or program-embedded evaluations of AI conducted within European-style population screening programs and to estimate exploratory program-level absolute risk differences (RDs) per 1000 examinations for cancer detection rate (CDR) and recall. MATERIALS AND METHODS: We performed a prespecified, focused evidence synthesis of three large studies embedded within routine population screening programs operating under European-relevant workflows: MASAI (randomized AI-supported risk triage within a national program), ScreenTrustCAD (prospective paired-reader evaluation with AI as an independent reader in a double-reading framework), and PRAIM (nationwide decision-referral implementation). Outcomes were harmonized as AI-control RDs per 1000 examinations. Random-effects pooling used Hartung-Knapp-Sidik-Jonkman models. For the paired-reader design, sensitivity analyses applied a Kish effective sample-size approach across plausible within-examination correlations (&#x3c1;&#xa0;=&#xa0;0.3-0.8). Positive predictive value (PPV) and workflow/time outcomes were summarized descriptively. RESULTS: Across 597,419 examinations, the pooled CDR RD was +0.9 per 1000 (95% CI -0.0 to +1.8; I2&#xa0;&#x2248;&#xa0;12%), consistent with a modest directional increase with borderline statistical uncertainty. The pooled recall RD was -0.6 per 1000 (95% CI -3.1 to +2.1; I2&#xa0;&#x2248;&#xa0;41-43%), indicating no consistent recall increase across screening programs. Where reported, PPV was higher with AI-supported screening. Efficiency signals included 44.3% fewer total readings in MASAI and shorter reading times for AI-normal examinations in PRAIM; in PRAIM, a program-level safety-net mechanism recovered 204 cancers that would otherwise have been missed. CONCLUSION: In European population screening programs characterized by double reading and arbitration, prospective program-embedded evidence suggests that AI integration may yield a small absolute increase in cancer detection (&#x2248;1/1000) without a consistent increase in recall, alongside improved PPV and efficiency signals. These findings suggestAI primarily as a complementary reader within European screening workflows, with implementation requiring explicit quality assurance and monitoring of interval cancers and stage distribution.

Humans

Longitudinal Prediction of Retinal Sensitivity Based on Disease Progression Quantified From Optical Coherence Tomography in Geographic Atrophy.

PURPOSE: The purpose of this study was to analyze the association between disease progression of geographic atrophy (GA) from optical coherence tomography (OCT) with retinal sensitivity (RS) in microperimetry (MP) over a 2-year follow-up period. METHODS: This is a longitudinal analysis of the OAKS Phase-III clinical trial. Both study and fellow eyes with GA that underwent imaging with the Spectralis OCT and consecutive MP examination were eligible. Pointwise quantification of ellipsoid zone (EZ) thickness, EZ and retinal pigment epithelium (RPE) loss from OCT volumes was correlated with localized RS. A longitudinal predictive model using a Markov Chain framework was implemented to predict RS change over time based on OCT biomarkers. The modeling of morphological and functional progression was based on the fellow-eye cohort. RESULTS: A total of 39,681 MP points from 406 patients were analyzed. In the fellow eye cohort, baseline (BSL) EZ thickness was positively associated with RS (0.3 decibel [dB]/&#xb5;m, P < 0.001). Decrease in EZ thickness between visits during follow-up was significantly associated with decrease in RS (0.1 dB / 1&#xa0;&#xb5;m change). RS was significantly lower in MP points within EZ loss during follow-up compared with MP points within the retina with measurable EZ (P < 0.001). The largest functional decline was observed within RPE loss, also associated with the highest probability of absolute scotoma (P < 0.001). Morphological progression to EZ and RPE loss was influenced by EZ thickness and the morphology of adjacent MP points (P < 0.001). CONCLUSIONS: Two exploratory endpoints were developed, namely quantification of EZ thickness and loss, and localized RS within high-risk OCT areas. RS decline during follow-up is associated with automatically quantified disease progression in OCT.

Humans

A multi-scale fusion model based on multi-phase contrast-enhanced CT for predicting pancreatic cancer resectability.

Purpose.Develop a multi-scale fusion model (MSFM) based on multi-phase contrast-enhanced computed tomography (CECT) to predict pancreatic cancer (PC) resectability, thereby assisting expert decision-making.Methods.This retrospective study enrolled 280 patients with PC from four institutions, which were randomly divided into a training cohort (202 patients) and an independent test cohort (78 patients). Three-phase CECT images (arterial, venous, and delayed phases) were used for modeling. The MSFM comprises two sub-networks: (1) a multi-phase fusion network for extracting cross-phase shared fusion features, (2) a phase-specific branch network for capturing phase-specific features; and a post-fusion strategy to generate the final predictive score by integrating the shared fusion features and three groups of phase-specific features. Additionally, a human-machine fusion deep learning model (HMfDL) was constructed by fusing the predictive score of the MSFM with expert assessments.Results.In the independent test, the MSFM achieved an AUC (area under the receiver operating characteristic curve) of 0.8385 (95% CI: 0.7521-0.9249), accuracy of 84.62%, sensitivity of 72.00%, and specificity of 90.57%. This performance outperformed single-phase models (AUC range: 0.7638-0.7781), two-phase models (AUC range: 0.7826-0.7864), and ten states-of-the-art classifiers (AUC range: 0.7404-0.7796). The HMfDL further improved the performance, reaching an AUC of 0.8626 (95% CI: 0.7853-0.9400), accuracy of 91.03%, sensitivity of 80.00%, and specificity of 96.23%. Notably, the HMfDL corrected 58.82% of misdiagnosis made by experts.Conclusions. The MSFM effectively fuses multi-phase CECT to enable highly accurate predictions of PC resectability, and provides valuable support for expert decision-making through HMfDL.

Humans