Search PubMedSearch

SEARCH · Search PubMed

Results for “corneal dystrophy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

18 recordsLinked to original sources

Cryo-EM structure of TGFBIp fibrils driven by a corneal dystrophy-linked mutation enables design of peptide inhibitors of aggregation.

Corneal dystrophy is a heterogeneous group of diseases which manifests clinically by progressive corneal opacity and diminishing visual acuity. A group of corneal dystrophies are linked to autosomal dominant mutations in transforming growth factor β-induced protein (TGFBIp) and characterized by extracellular amyloid-positive deposits of unknown molecular structure. Here, we determined the cryogenic-electron microscopy (cryo-EM) structure of amyloid fibrils formed by the TGFBIp FAS1-4 domain with corneal dystrophy-linked mutation V624M. The L569 to N609 fibril core, which includes the Y571-R588 segment enriched in patient corneal deposits, forms symmetrical protofilaments with internal solvent channels. Leveraging this structure, we designed peptide inhibitors intended to bind onto fibril ends to block elongation, targeting the unequal growth of symmetrical protofilaments. Our G1 and H4 inhibitors exhibit concentration-dependent reduction of TGFBIp FAS1-4 aggregation as assessed by Thioflavin T, solubility fractionation, and electron microscopy. Our work illustrates how fibril structures can guide rational inhibitor design and suggests the targeting of protein aggregates as a therapeutic approach for corneal and ocular diseases.

betaIG-H3 Protein

Descemet Stripping Only in Fuchs Endothelial Corneal Dystrophy: Results of a Randomized Clinical Trial of Topical Ripasudil and Directions for Future Innovation.

PURPOSE: To review history of Descemet stripping only (DSO) in Fuchs endothelial corneal dystrophy, describe the results of a clinical trial of topical ripasudil after DSO (K-321-201 study), and discuss future directions. METHODS: A 1-year, phase 2, randomized, placebo-controlled multicenter clinical trial of two doses of K-321 (ripasudil) administered for 12 weeks after DSO surgery in Fuchs endothelial corneal dystrophy was performed. The primary endpoint, central corneal endothelial cell density (ECD) at 12 weeks after surgery, was determined by an independent reading center that was masked to study group assignment. Duration of corneal edema, need for medical or surgical rescue therapy, corneal thickness, and central ECD throughout the entire study period were also examined. Adverse events and exploratory endpoints were collected. RESULTS: Sixty-five subjects were enrolled (21 in the QID group, 22 in the BID, and in the placebo group). Over 95% of subjects completed the trial. The QID group had a higher central ECD 12 weeks after DSO than the placebo group (531 &#xb1; 312 cells/mm2 vs 228 &#xb1; 298 cells/mm2, P = .0065). Corneal edema cleared in 17/21 (81.0%) of the QID group at 12 weeks, compared with 2/22 (9.1%) of the placebo group (P < .0001). Rescue was required in 2/21 (9.5%) subjects in the QID group and 6/22 (27.3%) subjects in the placebo group (P = .0092). Adverse events were mild and did not lead to discontinuation of treatment. CONCLUSIONS: Topical K-321 given QID improves DSO outcomes, as demonstrated by a higher ECD, more rapid resolution of corneal edema, and reduced failure rate. The medication was well-tolerated.

Humans

Improving survival in Duchenne muscular dystrophy across eras: a systematic review and cumulative meta-analysis.

BACKGROUND: Duchenne muscular dystrophy (DMD) was historically associated with death in the late teens or early twenties, mainly from respiratory failure. Survival has improved substantially with home mechanical ventilation (HMV) and multidisciplinary care, although variability remains. This study evaluated temporal trends in survival in DMD and the impact of HMV. METHODS: A study-level cumulative meta-analysis (PROSPERO CRD420251163011) of studies reporting survival outcomes in patients with DMD was conducted (PubMed 1977 to 13 October 2025). Pooled estimates of median survival were calculated, and random-effects meta-analyses with predefined subgroups (HMV and study period) were performed, alongside meta-regressions. Risk of bias was assessed using the Newcastle-Ottawa Scale. RESULTS: 53 studies (median follow-up 8&#xa0;years), comprising more than 13,000 patients, of whom 60% received HMV, were included. Median survival differed substantially between ventilated (29&#xa0;years, 95%CI 27 to 31) and non-ventilated (19&#xa0;years, 95%CI 18 to 20) patients. Survival improved progressively over time in both groups. Glucocorticoid therapy was not associated with improved survival (p=0.45), whereas treatment with heart failure medications, including renin-angiotensin system inhibitors (p=0.002) and &#x3b2;-blockers (p=0.02), was associated with longer survival. The predominance of mortality shifted from respiratory to cardiac causes, while enhanced cardiac management was associated with a growing contribution of other causes of death. CONCLUSION: Survival in DMD has increased substantially over time, with median survival now approaching the third decade of life among ventilated patients. The growing contribution of cardiac and other non-respiratory causes of death highlights the importance of long-term multidisciplinary and early cardioprotective intervention. STUDY REGISTRATION: The meta-analysis and systematic review have been registered on PROSPERO (CRD420251163011).

Humans

Corneal Epithelial Alterations Associated With Cyclin-Dependent Kinase 4/6 Inhibitor Therapy in Hormone Receptor-Positive Breast Cancer.

IMPORTANCE: Cyclin-dependent kinase 4/6 (CDK4/6) inhibitors are standard therapy for hormone receptor-positive (HR+), HER2-negative breast cancer. By blocking the G1/S cell-cycle transition, these agents may impair renewal of the corneal epithelium. No controlled study has systematically evaluated corneal epithelial changes in patients receiving CDK4/6 inhibitors. OBJECTIVE: To determine whether CDK4/6 inhibitor-based therapy is associated with cornealepithelial alterations independent of aromatase inhibitor exposure and tear film dysfunction. DESIGN, SETTING, AND PARTICIPANTS: Retrospective comparative cross-sectional study at a tertiary ophthalmology center. A total of 132 women were enrolled: 45 receiving a CDK4/6 inhibitor plus an aromatase inhibitor (CDKAI group), 44 receiving aromatase inhibitor monotherapy (AI group), and 43 age-matched postmenopausal controls without systemic oncologic therapy. EXPOSURES: CDK4/6 inhibitor (ribociclib, palbociclib, or abemaciclib) combined with an aromatase inhibitor; aromatase inhibitor alone; or no systemic oncologic therapy. MAIN OUTCOMES AND MEASURES: Prevalence and severity of punctate epitheliopathy and vortex keratopathy, assessed by a masked ophthalmologist. Secondary outcomes included Schirmer I test, tear film break-up time, and Ocular Surface Disease Index (OSDI). RESULTS: PE was present in 44.4% of eyes in the CDKAI group vs 4.7% in the AI group and 2.3% in controls (&#x3c7;&#xb2; = 34.31; P < .001). All moderate (13.3%) and severe/complicated (8.9%) PE cases occurred exclusively in the CDKAI group. Vortex keratopathy was observed in 13.3% of CDKAI patients and in none of the other groups (P = .025). Schirmer values, tear film break-up time, and OSDI scores did not differ among groups (all P > .05). Within the CDKAI group, PE was not associated with treatment duration (P = .963) or tear film parameters. CONCLUSIONS AND RELEVANCE: In this comparative study, CDK4/6 inhibitor-based therapy was associated with significantly higher prevalence and severity of PE and vortex keratopathy, independent of aromatase inhibitor exposure and in the absence of measurable tear film dysfunction. These findings suggest a direct cytostatic effect on the corneal epithelium. Symptom scores were low, although OSDI interpretation was limited by incomplete responses. Proactive corneal surface evaluation with fluorescein staining may be warranted during CDK4/6 inhibitor treatment.

Humans

Evaluation of a cornea-specialized large language model for diagnostic and management accuracy in complex corneal cases.

PURPOSE: To evaluate whether a cornea-specialized large language model (LLM) enhanced with retrieval-augmented generation (RAG) improves clinicians' diagnostic and management accuracy in complex corneal cases compared to a general-purpose GPT-4o model and unaided clinician performance. METHODS: This prospective, randomized, masked evaluation study involved three cornea trainees who each independently reviewed 39 real-world corneal cases under three experimental conditions: unaided, GPT-4o-assisted, and assisted by a cornea-specialized GPT-4o model. The cornea-specialized model was constructed by embedding over 200 publicly available Wikipedia articles into GPT-4o's RAG framework. Participants provided open-ended diagnoses and selected the next-step management options (multiple choice). They were allowed up to three GPT-4o queries per case, and the AI-assisted arms were randomized to minimize bias. Accuracy for both tasks was compared against expert reference standards using McNemar's test. RESULTS: Diagnostic accuracy was 48.7%, 20.5%, and 38.5% unaided, improving to 69.2%, 46.2%, and 59.0% with general GPT-4o (p<0.04). The cornea-specialized GPT-4o further improved accuracy to 71.8%, 48.7%, and 74.4%, with improvements over unaided performance for all clinicians (p<0.01). For next-step decisions, unaided accuracy was 76.9%, 87.2%, and 59.0%. With the specialized model, Ophthalmologist 3 improved to 71.8% (p<0.05), Ophthalmologist 1 remained high at 82.1%, and Ophthalmologist 2 declined to 64.1% (p<0.05). CONCLUSIONS: A cornea-specialized LLM enhanced with RAG improved diagnostic accuracy in complex corneal cases, particularly among clinicians with lower baseline performance. Effects on management accuracy were inconsistent. Future studies should explore the use of open-ended management tasks and examine whether smaller, curated retrieval corpora yield better model performance.

Humans

A case report of Xp21 contiguous gene deletion syndrome with adrenal crisis and sensorineural hearing loss: clinical highlights and management pitfalls.

OBJECTIVES: To report a rare association of Xp21 contiguous gene deletion syndrome (CGDS) featuring sensorineural hearing loss (SNHL), and to discuss the diagnostic and therapeutic challenges. CASE PRESENTATION: A male infant presented with a salt-wasting adrenal crisis consistent with X-linked adrenal hypoplasia congenita. His follow-up clinical course during childhood revealed global developmental delay and SNHL, the latter of which has been under-reported in the literature for this condition. At five years of age, the development of progressive proximal muscle weakness and markedly elevated creatine phosphokinase levels led to a diagnosis of Duchenne muscular dystrophy (DMD). The patient also exhibited pseudohypertriglyceridemia and elevated urinary glycerol, consistent with glycerol kinase deficiency. While initial exome sequencing failed to detect the genetic abnormality, subsequent chromosomal microarray analysis identified an Xp21 CGDS involving NR0B1, IL1RAPL1, DMD, and GK. Treatment of adrenal insufficiency with fludrocortisone and hydrocortisone was complicated by the higher steroid doses required for the management of DMD, resulting in exogenous Cushing syndrome and associated complications. CONCLUSIONS: This case highlights the necessity of evaluating for Xp21 CGDS in patients presenting with adrenal crisis and emphasizes the importance of multidisciplinary management to optimize outcomes in this complex pediatric endocrine disorder.

Humans

Second-Generation ELZA-sub400 Protocol: Individualized High-Fluence Cross-Linking for Ultra-Thin Keratoconus Corneas.

PURPOSE: To evaluate the safety and efficacy of a second-generation individualized corneal cross-linking (CXL) protocol (ELZA-sub400) using high-fluence UV-A irradiation in ultrathin ectatic corneas. DESIGN: Retrospective, single-center, consecutive interventional case series. METHODS: Twenty-nine eyes of 24 patients with progressive keratoconus or post-LASIK ectasia and a post-soak intraoperative thinnest stromal thickness <400 &#xb5;m were included. After epithelial removal and riboflavin soaking, continuous UV-A irradiation (365 nm) at 3 or 9 mW/cm&#xb2; was delivered with total fluence titrated up to 10 J/cm&#xb2; based on intraoperative ultrasound pachymetry and a previously published nomogram targeting an uncross-linked stromal margin of approximately 70 &#xb5;m above the endothelium. Outcomes were assessed at baseline and up to 12 months using corrected distance visual acuity (CDVA) and corneal parameters measured using Scheimpflug tomography and anterior segment OCT (AS-OCT) with Placido-based topography. The main outcome measure was the proportion of eyes without progression at 12 months, defined as <1.0 D increase in maximum keratometry (Kmax). Secondary outcomes included changes in CDVA, refraction, Kmax, stromal thickness, demarcation line depth, densitometry, and safety parameters. RESULTS: At 12 months, 22/29 eyes (76%; 95% CI, 57.9%-87.8%) met the nonprogression criterion. Mean change in Kmax was -0.77 &#xb1; 5.10 D (95% CI, -2.71 to 1.17; P = .418). Mean demarcation line-to-anterior stroma distance was 205 &#xb1; 64 &#xb5;m (95% CI, 180.7-229.3), and demarcation line-to-endothelium distance was 64 &#xb5;m (IQR, 49-152). All demarcation lines remained within the stromal layer; 15/29 eyes (51.7%) had a demarcation line located &#x2264;70 &#xb5;m from the endothelium. Median CDVA changed from 0.10 to 0.32 logMAR (P = .142). Minimum stromal thickness showed a median change of -4.0 &#xb5;m (P = .309). No significant change was observed in densitometry, and no eye developed deep stromal haze or endothelial decompensation. CONCLUSIONS: Second-generation ELZA-sub400 CXL halted ectasia progression in 76% of ultrathin corneas at 12 months and was associated with an acceptable short-term safety profile, including stromal-confined demarcation line formation and no observed endothelial decompensation. The numerical decline in spectacle CDVA observed in this severely affected cohort did not reach statistical significance but is clinically important and warrants confirmation in larger prospective studies.

Humans

Astigmatic vector outcomes after FS-LASIK versus SMILE for high myopic astigmatism: a single-center retrospective comparative cohort study without cyclotorsion compensation.

PURPOSE: To compare astigmatic correction vector outcomes between femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and small-incision lenticule extraction (SMILE, also termed Keratorefractive Lenticule Extraction, KLEx) without intraoperative cyclotorsion compensation in patients with high myopic astigmatism (-&#x2009;2.00 to&#x2009;-&#x2009;3.75 D), and to clarify procedure-specific correction tendencies under this non-standardized alignment protocol. METHODS: This single-center retrospective comparative cohort study enrolled 155 eyes (one eye randomly selected per patient) that underwent FS-LASIK (80 eyes) or SMILE/KLEx (75 eyes) for high myopic astigmatism correction from January 2023 to July 2024 in Beijing Fenglian Jiayue Lige Clinic. Intraoperative cyclotorsion compensation was intentionally disabled to isolate inherent procedural astigmatism correction characteristics. Standardized Alpins vectorial analysis was performed at 3&#xa0;months and 12&#xa0;months postoperatively. PRIMARY ENDPOINT: 12-month Alpins correction index (CI). Multivariable propensity score adjustment was applied to mitigate confounding by clinical treatment selection bias. Statistical multiplicity control was implemented for secondary vector and visual outcomes. RESULTS: Baseline demographic, refractive, corneal and ocular biometric parameters were balanced between groups after propensity matching. No statistically significant intergroup differences were detected in uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), residual cylinder, safety index or efficacy index at 3 and 12&#xa0;months (all P&#x2009;>&#x2009;0.05). Under the non-cyclotorsion-compensated protocol, significant intergroup differences were identified in the magnitude of surgically induced astigmatism (SIA), correction index (CI), and magnitude error (ME) at both follow-up timepoints (all P&#x2009;<&#x2009;0.0001). Target induced astigmatism (TIA), difference vector (DV), index of success (IOS), and angle error (AE) magnitudes were comparable between groups (all P&#x2009;>&#x2009;0.05). The vector mean axis of DV differed significantly between groups at 3 and 12&#xa0;months (Watson-Williams circular test, all P&#x2009;<&#x2009;0.0001). No reoperations were documented in clinic medical records for either cohort. No standardized dry eye questionnaires, tear film testing or corneal nerve density metrics were collected to quantify dry eye adverse events; only unstructured clinical notes were reviewed for complication screening. CONCLUSIONS: Under surgical alignment without cyclotorsion compensation, FS-LASIK and SMILE/KLEx both yielded acceptable visual and refractive safety/efficacy for high myopic astigmatism (-&#x2009;2.00 to&#x2009;-&#x2009;3.75 D) at 1-year follow-up, but demonstrated divergent astigmatism correction tendencies: FS-LASIK exhibited relative astigmatism overcorrection (vector mean DV:&#x2009;-&#x2009;0.35&#x2009;&#xb1;&#x2009;0.43 D&#x2009;&#xd7;&#x2009;91&#xb0;, CI&#x2009;>&#x2009;1), while SMILE/KLEx showed relative undercorrection (vector mean DV:&#x2009;-&#x2009;0.21&#x2009;&#xb1;&#x2009;0.53 D&#x2009;&#xd7;&#x2009;12&#xb0;, CI&#x2009;<&#x2009;1). These correction biases are specific to the study's manual limbal alignment protocol without cyclotorsion tracking and cannot be generalized to modern optimized surgical platforms equipped with automated cyclotorsion compensation. Residual refractive errors across both groups are likely multifactorial, including differential corneal stromal healing responses, divergent femtosecond/excimer laser tissue modification mechanisms, and uncorrected intraoperative ocular cyclotorsion.

Humans

Seventeen-year follow-up of hypophosphatasia diagnosed in middle-aged siblings harboring a novel intronic and a rare missense ALPL gene mutation.

Hypophosphatasia (HPP) is the rare inborn-error-of-metabolism that features impaired mineralization of the skeleton and teeth due to a deactivating mutation or mutations of the gene ALPL which encodes the tissue-nonspecific isoenzyme of alkaline phosphatase (TNSALP). We report 17-year follow-up of twin sisters and a brother referred in middle-age for painful proximal femoral "stress fractures" and then diagnosed with HPP. They reported generalized muscle and bone pain, metatarsal fractures, arthropathy and, since childhood, tooth loss. Their concordant findings were explained by compound heterozygosity in ALPL for a rare maternal missense mutation (c.1403C&#xa0;>&#xa0;T, p.Ala468Val) in exon 12, together with a novel presumably paternal change (c.863-14G&#xa0;>&#xa0;A) predicting a cryptic mRNA splice site in intron 8. Fractures continued during follow-up until one sister received a three-and-one-half-year course of hydroxyapatite-targeted TNSALP supplementation therapy (asfotase alfa) during which substantial improvement occurred in her clinical, biochemical, and functional parameters as well as quality of life. Following subsequent unplanned treatment cessation she suffered significant clinical deterioration, including new fractures and loss of mobility. Her bone histopathology documented osteomalacia. Treatment resumption restored its benefits. Among ten asymptomatic family members evaluated in this four-generation kindred, eight were carriers heterozygous for either ALPL mutation. Those harboring the maternal missense defect manifested mild hypophosphatasemia, suggesting a dominant-negative mutation effect. This experience underscores the importance of in-depth phenotyping and then clinical follow-up to characterize ALPL variant combinations, and for maintaining effective asfotase alfa treatment.

Humans

Posterior Segment Risk Factors for Penetrating Keratoplasty Failure.

PURPOSE: To analyze the relationship between intraoperative and postpenetrating keratoplasty (PK) posterior segment variables and PK graft survival. DESIGN: Retrospective clinical cohort study. SUBJECTS: Patients undergoing PK between May 1, 2007 and September 1, 2018 at a single tertiary center. METHODS: Chart review for PKs performed was conducted, and the first PK completed at the institution for each patient was included for analysis. Data collected included demographics, medical and ocular history, preoperative and intraoperative findings, and intraoperative and postoperative posterior segment factors (pars plana vitrectomy [PPV], endolaser, retinal detachment [RD], and vitreous hemorrhage [VH]). After univariable analysis, variables were selected for multivariable Cox regression analysis. MAIN OUTCOME MEASURE: Graft failure, defined as irreversible and visually significant corneal edema, haze, or scarring. RESULTS: Eight hundred and thirty-five eyes of 835 patients were included. Mean age was 57.1 &#xb1; 22.0 (range: 0-100) years, and mean time from PK to final follow-up or graft failure was 3.2 &#xb1; 2.9 (range: 0.01-16.1) years. Graft failure occurred in 35.0% of cases with a mean onset of 1.9 &#xb1; 2.0 (range: 0.04-11.4) years after PK. After multivariable analysis, 9 variables had significant associations with failure. Two posterior segment variables were significant: intraoperative VH at the time of PK (hazard ratio [HR] 6.6, 95% confidence interval [CI] 1.6-27.7, P = .010) and silicone oil (SO) tamponade after the PK (HR 3.2, 95% CI 1.4-7.4, P = .007). CONCLUSIONS: Graft failure is a serious complication of PK. VH at the time of the PK and SO tamponade after the PK were associated with graft failure. In complex eyes that are undergoing PK grafts and that may also require posterior segment interventions, these findings may guide patient counseling and discussion of graft prognosis.

Humans

Clinical Outcomes and Genomic Epidemiology of Multidrug-Resistant Methicillin-Resistant Staphylococcus aureus Keratitis.

PURPOSE: To characterize the clinical features, management, antimicrobial resistance patterns, and genomic epidemiology of methicillin-resistant Staphylococcus aureus (MRSA) keratitis at two North American centers. DESIGN: Retrospective interventional case series combined with laboratory investigation PARTICIPANTS: Seventy eyes of 67 patients presenting laboratory-confirmed MRSA keratitis were included METHODS: We performed a multicenter retrospective case series of patients with culture-proven MRSA keratitis treated between 2005 and 2022. Demographic and clinical data were collected. Antimicrobial susceptibility testing was conducted, and multidrug resistance (MDR) was defined as resistance to &#x2265;3 antibiotic classes. A subset of isolates underwent whole-genome sequencing with core genome multilocus sequence typing. Vancomycin susceptibility, heteroresistance screening, and tolerance testing were performed on available isolates. MAIN OUTCOME MEASURES: Antimicrobial susceptibility and multidrug resistance rates, vancomycin phenotypic profiles, MRSA genotypic distribution, and final best-corrected visual acuity RESULTS: Median age was 63.5 years, and 61.4% were female. Ocular surface disease (67.7%) and prior ocular surgery (65.2%) were common. Only 25.4% had significant healthcare exposure in the preceding year. Most isolates (85.7%) were MDR. Fluoroquinolone susceptibility was low (moxifloxacin 19.7%). All isolates were susceptible to vancomycin (MIC&#x2089;&#x2080; 2 &#xb5;g/mL), and no vancomycin-intermediate, heteroresistant, or tolerant phenotypes were identified. Whole genome sequencing (n = 41) demonstrated predominance of clonal complexes 5 (68.3%) and 8 (29.2%). Visual outcomes were poor, with most patients (85.2%) having a final visual acuity worse than 20/60 among those with follow-up. CONCLUSIONS: MRSA keratitis is associated with high rates of multidrug resistance and poor visual outcomes despite guideline-based therapy. Infections were predominantly caused by CC5 MDR strains despite limited recent healthcare exposure. These findings highlight the persistence of highly resistant MRSA lineages in community-associated corneal infection and underscore the need for ongoing antimicrobial surveillance and optimized treatment strategies.

Humans

Impact of Contact Lens Use on Clinical Profile and Outcomes of Fungal Keratitis: An 8-Year Retrospective Study.

PURPOSE: To compare clinical characteristics, microbiological profiles, treatment strategies, and outcomes between contact lens-associated (CL) and noncontact lens-associated (non-CL) fungal keratitis. DESIGN: Retrospective, comparative clinical cohort study. METHODS: A review of culture-proven fungal keratitis treated at a tertiary referral center between 2018 and 2025 was conducted. Cases were categorized as CL or non-CL-associated. Demographic, clinical, microbiological, treatment, and outcome data were analyzed and compared between groups. RESULTS: Thirty-seven eyes were included, comprising 16 CL and 21 non-CL cases. CL users presented earlier than non-CL patients (median 7 vs 14 days, P = .007) and had fewer associated ocular risk factors (31% vs 81%, P = .001). Baseline visual acuity and infiltrate size did not differ significantly between groups. Candida species were isolated in 21% cases, Fusarium in 16% and Aspergillus in 8%. Fusarium (19% vs 13%) and Candida (24% vs 19%) infections were slightly more frequent in non-CL cases. Overall, filamentous fungi were the predominant organism group. Topical voriconazole was the most frequently used antifungal agent (78%). All CL-associated cases resolved with medical therapy alone, with a median time to resolution of 38 days (IQR 22-58). In contrast, 76% of non-CL cases resolved medically (median 42 days, IQR 32-76), while 23% required therapeutic keratoplasty (P = .04). Final visual acuity was comparable between groups (logMAR 0.2 vs 0.5, P = .56). CONCLUSION: Contact lens-associated fungal keratitis is characterized by earlier presentation and fewer underlying ocular comorbidities, with favorable outcomes achieved through medical therapy alone. Despite similar microbiological profiles and treatment approaches, noncontact lens-associated fungal keratitis more frequently follows a complicated course requiring surgical intervention.

Humans

Molecular diagnostic yield and barriers in inherited retinal diseases: a retrospective cohort study.

OBJECTIVE: To evaluate the diagnostic yield of panel-based genetic testing for inherited retinal diseases (IRDs) and identify barriers to molecular resolution. DESIGN: Retrospective cohort. PARTICIPANTS: A total of 404 patients with clinically confirmed IRDs who were evaluated at the Adult Inherited Retinal Dystrophy Service, Ontario, Canada (October 2021-September 2024). METHODS: Patients underwent targeted massive parallel sequencing panel testing. Diagnostic yield was calculated, and unresolved cases were reviewed. Associations between yield, phenotype, ethnicity, and sex were assessed using &#x3c7;&#xb2; analysis. RESULTS: Of 685 referrals, 570 had confirmed IRDs. After we excluded 140 pending results and 26 patients who declined testing, 404 patients were analyzed. At referral, 94 patients (23.2%) had a previous molecular diagnosis, and 138 (34.0%) were diagnosed through clinic-initiated testing, giving an overall yield of 57.4%. Yield varied significantly by phenotype (&#x3c7;&#xb2;, P&#x202f;=&#x202f;1.4&#x202f;&#xd7;&#x202f;10&#x207b;&#x2076;), from 94.4% in vitelliform macular dystrophies to 25.0% in vitreoretinopathies, with no sex association (P&#x202f;=&#x202f;1.0). Disease-causing variants were identified in 83 IRD-associated genes, most frequently ABCA4, USH2A, and BEST1. Of 172 unresolved cases, 62 (36.0%) had negative panels, and 110 (63.9%) were inconclusive, including 30 with unphased pathogenic variants in recessive genes and 10 with high-suspicion variants of uncertain significance. Key barriers included limited family availability for phasing, restricted access to functional assays, and lack of public coverage for whole-exome or whole-genome sequencing. CONCLUSIONS: Massive parallel sequencing-based panel testing achieved a 57% diagnostic yield in this IRD population. Success was strongly phenotype-dependent with substantial heterogeneity. Whole-exome sequencing, whole-genome sequencing, family segregation, and functional genomics could improve diagnostic outcomes and management.

Humans

The effect of compression dressing on postoperative outcomes after upper eyelid blepharoplasty: a randomized, controlled, observer-blinded evaluation study.

PURPOSE: This study aimed to evaluate the impact of a compression dressing on postoperative pain, ocular surface changes, edema, ecchymosis, and aesthetic outcomes following upper eyelid blepharoplasty. METHODS: This observer-blinded, randomized, controlled trial included 112 eyelids from 56 patients who underwent bilateral upper eyelid blepharoplasty between June and August 2025. After surgery, one eyelid received a compression dressing (CD), while the other eyelid received no dressing (ND). Edema and ecchymosis were graded by masked observers on postoperative days 1, 7, 30, and 90. Aesthetic outcomes were evaluated using the Global Aesthetic Improvement Score. Pain was evaluated using a visual analog scale, and patient comfort was assessed by side preference. RESULTS: On postoperative day 1, ecchymosis scores were significantly lower in the CD group than in the ND group (unadjusted p = 0.002; Holm-adjusted p = 0.012). Edema scores were also lower on the CD side (unadjusted p = 0.012) and aesthetic scores were higher (unadjusted p = 0.046); however, neither difference remained statistically significant after Holm-Bonferroni correction for multiple comparisons (adjusted p = 0.060 and p = 0.138, respectively). No significant differences were observed in any parameter on postoperative days 7, 30, or 90 (all adjusted p > 0.05). Corneal staining scores were comparable between groups at all follow-ups, and no corneal erosions were observed. Pain scores on day 1 were similar (p = 0.977). CONCLUSIONS: Compression dressing after upper eyelid blepharoplasty was associated with a significant reduction in early postoperative ecchymosis, an effect that persisted after correction for multiple comparisons. Reductions in edema and improvements in aesthetic scores were observed on postoperative day 1 but did not remain statistically significant after adjustment. Overall, the benefits of compression dressing were limited in magnitude and transient, and routine use may not be necessary; its application should be individualized according to patient needs. TRIAL REGISTRATION: ClinicalTrials.gov, NCT07701265 (retrospectively registered on July 8, 2026).

Humans

Continuous Intraperitoneal Insulin Infusion for People With Type 1 Diabetes: A Literature Review and International Position Statement.

Achieving glucose targets without hypoglycaemia is the treatment goal in type 1 diabetes. Structured education, intensified insulin injection regimens, continuous glucose monitoring, automated insulin delivery, and ongoing support from a multidisciplinary team all support people with type 1 diabetes to achieve this goal. Despite these advances, significant barriers to achieving optimal management remain. Continuous intraperitoneal insulin infusion has comparable or better glucose outcomes to continuous subcutaneous insulin infusion and may reduce the frequency of hypoglycaemia, including severe episodes. Intraperitoneal insulin may be considered as a treatment modality for children and adults with type 1 diabetes using optimised intensive insulin therapy for whom subcutaneous insulin has failed due to lipoatrophy, -dystrophy or -hypertrophy, local allergy, subcutaneous insulin resistance or co-existing skin conditions. Failure of subcutaneous insulin may result in recurrent or unexplained severe hypoglycaemia or hyperglycaemia. Intraperitoneal insulin may also be considered as a treatment modality for people with type 1 diabetes with severe needle-phobia, and for those being considered for islet cell or pancreatic transplantation, or where transplantation is not available. This paper summarises current intraperitoneal insulin delivery technology, its potential risks and benefits, and an expert position statement. It is intended for use by diabetes specialist healthcare professionals, and as a reference for other healthcare professionals, commissioners, payors, people with diabetes, their carers, and advocates.

Humans

Xerophthalmia and ocular manifestations of vitamin A deficiency in children in high-income countries: A systematic review.

Xerophthalmia is a vision-threatening eye condition caused by vitamin A deficiency (VAD). Cases of xerophthalmia in high-income countries (HICs) are vulnerable to misdiagnosis, causing delays in treatment and adverse visual outcomes. We define the features, causes and complications of VAD and xerophthalmia in children of HICs. Our study followed the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines (CRD42024492023). We performed a search for eligible articles on Scopus, Web of Science, Cochrane, PubMed and Medline. Cases reporting on children under 18 years of age residing in HICs with ocular features of VAD were eligible for inclusion. The search yielded 2474 results; 43 case reports and case series met the inclusion criteria consisting of a total of 61 cases (mean age 9.9&#x202f;&#xb1;&#x202f;4.2 years, range 3-17 years). Xerophthalmia was graded according to the most advanced finding for each case: 21.3% had night blindness only; 29.5% had conjunctival xerosis or Bitot spots; 29.5% had corneal xerosis, ulceration or scarring; 1.6% had xerophthalmia fundus only; and 18.0% had ocular manifestations associated with VAD that are not encompassed under the WHO classification. These features included swollen optic discs, optic neuropathy, or ocular dryness. Restrictive dietary practises were the most common mechanism of deficiency (75%), and autism was the most common underlying condition (49%). This shows that VAD remains a cause of severe visual impairment in HICs, especially when associated with delays in diagnosis and treatment. Further research is required to establish the prevalence of xerophthalmia in HICs.

Humans

Axial Length Adjustment and AL/R Ratio Optimization of IOL Power Calculation in Extremely Long Eyes.

PURPOSE: To evaluate the accuracy of modern intraocular lens (IOL) power calculation formulas and axial length (AL) adjustment methods in eyes with AL &#x2265; 30.0 mm. DESIGN: Retrospective consecutive cross-sectional study. PARTICIPANTS AND CONTROLS: A total of 308 eyes (308 patients) with AL &#x2265; 30.00 mm were included. METHODS: Accuracy of modern online formulas, alone or with established AL adjustments methods, was analyzed. Subgroup analyses were performed based on AL, keratometry (K), anterior chamber depth (ACD), lens thickness (LT), and AL-to-corneal radius (AL/R) ratio. MAIN OUTCOME MEASURES: Predictive accuracy was evaluated using the formula performance index (FPI), root mean square absolute prediction error (RMSAE), standard deviation (SD) of prediction error (PE), and percentage of eyes within &#xb1;0.25 and &#xb1;0.50 diopters (D). RESULTS: Overall, Holladay 1 combined with the nonlinear polynomial Wang-Koch axial length adjustment (H1-PWK) demonstrated the best overall performance, achieving the lowest SD (0.40), RMSAE (0.40), and highest FPI (0.494). A tendency toward hyperopic error was observed in eyes with AL &#x2265; 32.0 mm, K &#x2265; 46.0 D. The AL/R ratio showed a significant positive correlation with PE in the Ladas Super formula, Barrett Universal II, EVO, PEARL-DGS, and Hoffer QST formulas. Spline-based regression analysis indicated that the transition point of AL/R from myopic to hyperopic PE varied across different formulas. CONCLUSIONS: H1-PWK provides robust refractive accuracy in extremely long eyes. The AL/R ratio may provide a useful composite biometric stratification parameter compared to AL alone.

Humans

Association Between 24-Hour Blood Pressure and Rates of Retinal Nerve Fiber Layer Progression in Glaucoma: The Vascular Imaging in Glaucoma Study.

PURPOSE: Low systemic blood pressure (BP) has been implicated as a risk factor for glaucoma progression. The purpose of this study was to investigate the association between 24-hour BP and rates of retinal nerve fiber layer (RNFL) loss in eyes with primary open-angle glaucoma. DESIGN: Prospective cohort study. PARTICIPANTS: Seventy-nine eyes from 42 subjects with glaucoma (mean age, 68.5 &#xb1; 7.6 years) enrolled in the Vascular Imaging in Glaucoma Study at the Bascom Palmer Eye Institute. METHODS: Participants underwent 24-hour ambulatory BP monitoring at baseline. Follow-up evaluations were conducted at 4-month intervals and included ophthalmic examination, BP measurement, and peripapillary RNFL thickness measurement with spectral-domain optical coherence tomography. The association between BP and RNFL loss over time was assessed using linear mixed-effects models adjusted for age, sex, race, baseline RNFL thickness, central corneal thickness, and intraocular pressure. MAIN OUTCOME MEASURES: The effect of baseline 24-hour mean arterial pressure (MAP), systolic BP (SBP), and diastolic BP (DBP) on the rate of average RNFL loss over time. RESULTS: Eyes underwent an average of 13 &#xb1; 3 optical coherence tomography exams over 43 &#xb1; 10 months of follow-up. The mean rate of RNFL loss was -0.34 &#xb1; 0.64 &#xb5;m/y (median: -0.32; interquartile range: -0.66 to -0.04 &#xb5;m/y). After adjusting for confounding factors, every 10 mm Hg lower in 24-hour minimum MAP, SBP, and DBP was associated with -0.542 &#xb5;m/y (P < .001), -0.360 &#xb5;m/y (P = .003), and -0.458 &#xb5;m/y (P = .008) faster RNFL loss, respectively. Eyes in the lowest quartile of average 24-hour MAP (81-90 mm Hg) and minimum 24-hour DBP (35-47 mm Hg) experienced significantly faster progression compared to those in the highest quartile, with differences of -0.68 &#xb5;m/y (P = .017) and -0.63 &#xb5;m/y (P = .030), respectively. CONCLUSIONS: Lower systemic BP, especially minimum MAP, SBP, and DBP measured by 24-hour ambulatory BP monitoring, is associated with faster rates of RNFL loss in primary open-angle glaucoma eyes. 24-hour BP monitoring may help predict glaucoma patients at greater risk of progression.

Humans