Search PubMedSearch

PubMed · 42364705

Second-Generation ELZA-sub400 Protocol: Individualized High-Fluence Cross-Linking for Ultra-Thin Keratoconus Corneas.

Abstract

PURPOSE: To evaluate the safety and efficacy of a second-generation individualized corneal cross-linking (CXL) protocol (ELZA-sub400) using high-fluence UV-A irradiation in ultrathin ectatic corneas. DESIGN: Retrospective, single-center, consecutive interventional case series. METHODS: Twenty-nine eyes of 24 patients with progressive keratoconus or post-LASIK ectasia and a post-soak intraoperative thinnest stromal thickness <400 &#xb5;m were included. After epithelial removal and riboflavin soaking, continuous UV-A irradiation (365 nm) at 3 or 9 mW/cm&#xb2; was delivered with total fluence titrated up to 10 J/cm&#xb2; based on intraoperative ultrasound pachymetry and a previously published nomogram targeting an uncross-linked stromal margin of approximately 70 &#xb5;m above the endothelium. Outcomes were assessed at baseline and up to 12 months using corrected distance visual acuity (CDVA) and corneal parameters measured using Scheimpflug tomography and anterior segment OCT (AS-OCT) with Placido-based topography. The main outcome measure was the proportion of eyes without progression at 12 months, defined as <1.0 D increase in maximum keratometry (Kmax). Secondary outcomes included changes in CDVA, refraction, Kmax, stromal thickness, demarcation line depth, densitometry, and safety parameters. RESULTS: At 12 months, 22/29 eyes (76%; 95% CI, 57.9%-87.8%) met the nonprogression criterion. Mean change in Kmax was -0.77 &#xb1; 5.10 D (95% CI, -2.71 to 1.17; P = .418). Mean demarcation line-to-anterior stroma distance was 205 &#xb1; 64 &#xb5;m (95% CI, 180.7-229.3), and demarcation line-to-endothelium distance was 64 &#xb5;m (IQR, 49-152). All demarcation lines remained within the stromal layer; 15/29 eyes (51.7%) had a demarcation line located &#x2264;70 &#xb5;m from the endothelium. Median CDVA changed from 0.10 to 0.32 logMAR (P = .142). Minimum stromal thickness showed a median change of -4.0 &#xb5;m (P = .309). No significant change was observed in densitometry, and no eye developed deep stromal haze or endothelial decompensation. CONCLUSIONS: Second-generation ELZA-sub400 CXL halted ectasia progression in 76% of ultrathin corneas at 12 months and was associated with an acceptable short-term safety profile, including stromal-confined demarcation line formation and no observed endothelial decompensation. The numerical decline in spectacle CDVA observed in this severely affected cohort did not reach statistical significance but is clinically important and warrants confirmation in larger prospective studies.

Explore related subjects

Keep this discovery

BibTeXRIS

Farhad Hafezi, R&#xfc;&#x15f;t&#xfc; Emre Akcan, Sabine Kling, L&#xe9;onard Kollros, Michalina Depczy&#x144;ska, Shady Awwad, Boris Knyazer, Nikki Hafezi, Frank Blaser, Mark Hillen, Emilio A Torres-Netto. 2026-06-27. Second-Generation ELZA-sub400 Protocol: Individualized High-Fluence Cross-Linking for Ultra-Thin Keratoconus Corneas.. https://doi.org/10.1016/j.ajo.2026.06.034

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

Corneal Epithelial Alterations Associated With Cyclin-Dependent Kinase 4/6 Inhibitor Therapy in Hormone Receptor-Positive Breast Cancer.

IMPORTANCE: Cyclin-dependent kinase 4/6 (CDK4/6) inhibitors are standard therapy for hormone receptor-positive (HR+), HER2-negative breast cancer. By blocking the G1/S cell-cycle transition, these agents may impair renewal of the corneal epithelium. No controlled study has systematically evaluated corneal epithelial changes in patients receiving CDK4/6 inhibitors. OBJECTIVE: To determine whether CDK4/6 inhibitor-based therapy is associated with cornealepithelial alterations independent of aromatase inhibitor exposure and tear film dysfunction. DESIGN, SETTING, AND PARTICIPANTS: Retrospective comparative cross-sectional study at a tertiary ophthalmology center. A total of 132 women were enrolled: 45 receiving a CDK4/6 inhibitor plus an aromatase inhibitor (CDKAI group), 44 receiving aromatase inhibitor monotherapy (AI group), and 43 age-matched postmenopausal controls without systemic oncologic therapy. EXPOSURES: CDK4/6 inhibitor (ribociclib, palbociclib, or abemaciclib) combined with an aromatase inhibitor; aromatase inhibitor alone; or no systemic oncologic therapy. MAIN OUTCOMES AND MEASURES: Prevalence and severity of punctate epitheliopathy and vortex keratopathy, assessed by a masked ophthalmologist. Secondary outcomes included Schirmer I test, tear film break-up time, and Ocular Surface Disease Index (OSDI). RESULTS: PE was present in 44.4% of eyes in the CDKAI group vs 4.7% in the AI group and 2.3% in controls (&#x3c7;&#xb2; = 34.31; P < .001). All moderate (13.3%) and severe/complicated (8.9%) PE cases occurred exclusively in the CDKAI group. Vortex keratopathy was observed in 13.3% of CDKAI patients and in none of the other groups (P = .025). Schirmer values, tear film break-up time, and OSDI scores did not differ among groups (all P > .05). Within the CDKAI group, PE was not associated with treatment duration (P = .963) or tear film parameters. CONCLUSIONS AND RELEVANCE: In this comparative study, CDK4/6 inhibitor-based therapy was associated with significantly higher prevalence and severity of PE and vortex keratopathy, independent of aromatase inhibitor exposure and in the absence of measurable tear film dysfunction. These findings suggest a direct cytostatic effect on the corneal epithelium. Symptom scores were low, although OSDI interpretation was limited by incomplete responses. Proactive corneal surface evaluation with fluorescein staining may be warranted during CDK4/6 inhibitor treatment.

Humans

Descemet Stripping Only in Fuchs Endothelial Corneal Dystrophy: Results of a Randomized Clinical Trial of Topical Ripasudil and Directions for Future Innovation.

PURPOSE: To review history of Descemet stripping only (DSO) in Fuchs endothelial corneal dystrophy, describe the results of a clinical trial of topical ripasudil after DSO (K-321-201 study), and discuss future directions. METHODS: A 1-year, phase 2, randomized, placebo-controlled multicenter clinical trial of two doses of K-321 (ripasudil) administered for 12 weeks after DSO surgery in Fuchs endothelial corneal dystrophy was performed. The primary endpoint, central corneal endothelial cell density (ECD) at 12 weeks after surgery, was determined by an independent reading center that was masked to study group assignment. Duration of corneal edema, need for medical or surgical rescue therapy, corneal thickness, and central ECD throughout the entire study period were also examined. Adverse events and exploratory endpoints were collected. RESULTS: Sixty-five subjects were enrolled (21 in the QID group, 22 in the BID, and in the placebo group). Over 95% of subjects completed the trial. The QID group had a higher central ECD 12 weeks after DSO than the placebo group (531 &#xb1; 312 cells/mm2 vs 228 &#xb1; 298 cells/mm2, P = .0065). Corneal edema cleared in 17/21 (81.0%) of the QID group at 12 weeks, compared with 2/22 (9.1%) of the placebo group (P < .0001). Rescue was required in 2/21 (9.5%) subjects in the QID group and 6/22 (27.3%) subjects in the placebo group (P = .0092). Adverse events were mild and did not lead to discontinuation of treatment. CONCLUSIONS: Topical K-321 given QID improves DSO outcomes, as demonstrated by a higher ECD, more rapid resolution of corneal edema, and reduced failure rate. The medication was well-tolerated.

Humans

Axial Length Adjustment and AL/R Ratio Optimization of IOL Power Calculation in Extremely Long Eyes.

PURPOSE: To evaluate the accuracy of modern intraocular lens (IOL) power calculation formulas and axial length (AL) adjustment methods in eyes with AL &#x2265; 30.0 mm. DESIGN: Retrospective consecutive cross-sectional study. PARTICIPANTS AND CONTROLS: A total of 308 eyes (308 patients) with AL &#x2265; 30.00 mm were included. METHODS: Accuracy of modern online formulas, alone or with established AL adjustments methods, was analyzed. Subgroup analyses were performed based on AL, keratometry (K), anterior chamber depth (ACD), lens thickness (LT), and AL-to-corneal radius (AL/R) ratio. MAIN OUTCOME MEASURES: Predictive accuracy was evaluated using the formula performance index (FPI), root mean square absolute prediction error (RMSAE), standard deviation (SD) of prediction error (PE), and percentage of eyes within &#xb1;0.25 and &#xb1;0.50 diopters (D). RESULTS: Overall, Holladay 1 combined with the nonlinear polynomial Wang-Koch axial length adjustment (H1-PWK) demonstrated the best overall performance, achieving the lowest SD (0.40), RMSAE (0.40), and highest FPI (0.494). A tendency toward hyperopic error was observed in eyes with AL &#x2265; 32.0 mm, K &#x2265; 46.0 D. The AL/R ratio showed a significant positive correlation with PE in the Ladas Super formula, Barrett Universal II, EVO, PEARL-DGS, and Hoffer QST formulas. Spline-based regression analysis indicated that the transition point of AL/R from myopic to hyperopic PE varied across different formulas. CONCLUSIONS: H1-PWK provides robust refractive accuracy in extremely long eyes. The AL/R ratio may provide a useful composite biometric stratification parameter compared to AL alone.

Humans