Search PubMedSearch

SEARCH · Search PubMed

Results for “Three-dimensional excitation-emission matrix (3D-EEM) fluorescence spectroscopy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

667 recordsLinked to original sources

Coupling of spectroscopy and nitrogen-oxygen isotopes unveils the mechanisms of dissolved organic matter and nitrate pollution in lakes within the agro-pastoral transition zone.

Lakes in arid and semi-arid regions are subjected to severe ecological stress, such as organic pollution, eutrophication, and salinization, due to climate change and human activities. This study investigates Chagannur Lake, a typical arid-region lake that is representative and ecologically sensitive in Northern China's agro-pastoral ecotone, to uncover its pollution characteristics and mechanisms. We employed fluorescence spectroscopy and stable isotope analysis to trace dissolved organic matter (DOM) and nitrate sources. The DOM composition was dominated by microbial metabolic byproducts and protein-like substances, suggesting that microbial processes are key to organic matter transformation. Source apportionment revealed that pollutants primarily originated from livestock and poultry manure (37.6 %), agricultural fertilizers (35.6 %), and soil erosion (24.7 %), with agricultural fertilizers contributing most significantly in the Gogstai River (63.3 %). A structural equation model (SEM) coupling spectral and mass spectrometric data revealed that microbial transformation significantly impairs the lake's self-purification capacity, thereby promoting pollutant accumulation (path coefficient = 0.91,*p < 0.05). Moreover, microbial processes link endogenous and exogenous pollution, a mechanism effectively traced by isotopic and fluorescence indices (path coefficient = 0.55, &#x204e;&#x204e;p < 0.01). These findings enhance the understanding of pollution sources and transformation mechanisms in arid-region lakes and offer foundational theoretical support for policymakers engaged in pollution control strategies.

Lakes

Volumetric bone marrow cellularity (VBMC) assessment from routinely processed trephines using three-dimensional x-ray histology and gaussian peak modelling.

Objective.Bone marrow cellularity is routinely estimated from a small number of two-dimensional histology sections, making assessment sensitive to section representativeness, processing artefacts and observer interpretation. Three-dimensional (3D) x-ray histology (XRH), using x-ray computed microtomography (&#xb5;CT), enables non-destructive whole-block imaging of trephine biopsies. This study evaluated whether XRH combined with Gaussian peak modelling could provide a pragmatic whole-block volumetric bone marrow cellularity (VBMC) estimate from formalin-fixed paraffin-embedded (FFPE) trephine biopsy blocks.Approach.Six routinely processed FFPE bone marrow trephine blocks were imaged using &#xb5;CT-based XRH at &#x223c;15 &#xb5;m spatial resolution. VBMC was defined as the red-marrow (RM) fraction of the marrow soft-tissue compartment, RM/(RM + intra-biopsy wax), with wax serving as the volumetric proxy for adipocyte/yellow marrow space. Whole-volume greyscale histograms were modelled using a three-peak Gaussian approach representing intra-biopsy wax, RM and demineralised trabecular matrix. Peak-height and area-under-the-curve metrics were compared with whole-volume 3D segmentation and clinical two-dimensional (2D) cellularity estimates.Main Results.Gaussian peak modelling successfully approximated the segmented tissue-phase distributions. The peak-height-derived VBMC metric showed the closest agreement with whole-volume 3D segmentation, with an average absolute percentage difference of 9.3%, compared with 18.6% for clinical expert 2D cellularity estimates. The area-under-the-curve metric followed similar trends but consistently overestimated VBMC. Clinical 2D cellularity broadly followed whole-biopsy trends but showed one discordant case not explained by slice-position sampling alone. XRH also enabled unrestricted virtual reslicing and visualisation of sectioning-associated artefacts prior to further microtomy.Significance.Pre-sectioning XRH combined with Gaussian peak modelling provides a rapid, segmentation-free route to volumetric cellularity estimation from intact clinical FFPE trephine blocks. The approach supports objective whole-biopsy assessment while remaining compatible with routine histopathology workflows, reflecting the expected limitations of section-based visual estimation despite its role as the current clinical standard. In the near term, it could provide a non-disruptive adjunct to conventional 2D cellularity reporting, pending larger validation studies.

Imaging, Three-Dimensional

A STORM-based protocol for nanoscale imaging and quantitative analysis of protein-associated and phospholipid-associated structures in natural rubber.

Stochastic Optical Reconstruction Microscopy (STORM) enables nanoscale mapping of molecular components beyond the diffraction limit; however, its reproducible implementation in hydrophobic polymer matrices remains challenging because fluorescence-labeling specificity, fluorophore photoswitching, three-dimensional localization, chromatic registration, and quantitative image analysis must be carefully controlled. This protocol presents a standardized experimental workflow for dual-color labeling, astigmatism-based three-dimensional STORM acquisition, and quantitative analysis of protein-associated and phospholipid-associated structures in natural rubber (NR). The workflow covers sample pretreatment, Cy5 NHS ester labeling of protein-associated primary amines, DiI labeling of phospholipid-rich domains, STORM imaging-buffer preparation, three-dimensional single-molecule localization, dual-channel registration, generation of standardized xy projections, aggregate-size analysis, and projected lateral spatial correlation assessment. Reproducibility is supported by defined acquisition and localization criteria, three independent sample preparations with at least five fields of view analyzed per condition, and unlabeled, single-color, dye-only matrix, and processing-associated Cy5 controls. Mean lateral localization precisions of 11.8&#x202f;&#xb1;&#x202f;2.3&#x202f;nm for Cy5 and 13.5&#x202f;&#xb1;&#x202f;2.9&#x202f;nm for DiI were obtained, while two-dimensional Fourier ring correlation analysis of the xy projections yielded effective lateral image resolutions of approximately 25 and 28&#x202f;nm, respectively. Image-based particle segmentation and localization-coordinate-based density-based spatial clustering of applications with noise (DBSCAN) were applied to standardized xy projections as complementary quantitative approaches. Application of the protocol to untreated, centrifuged, and protease-treated NR samples demonstrated treatment-associated changes in the detected abundance and projected size distributions of protein- and phospholipid-associated aggregates, together with a non-monotonic change in their projected lateral spatial correlation. These observations describe alterations in nanoscale organization but do not, by themselves, establish stable protein-phospholipid complex formation. Unlike previous studies that primarily demonstrated the feasibility of STORM imaging in rubber materials, the principal contribution of this work is an end-to-end, step-by-step protocol incorporating defined controls, three-dimensional localization, image-quality metrics, chromatic-registration procedures, and complementary quantitative-analysis pipelines for non-expert users. The workflow may be adaptable to other hydrophobic polymers and soft-material systems after appropriate optimization and validation.

Rubber

Application of Three-Dimensionally Printed Surgical Guides in Precise Sacral Tumor Excision and Defect Reconstruction.

OBJECTIVE: Precise resection of sacral tumors remains technically demanding due to their deep anatomical location and close proximity to critical neurovascular structures. Conventional freehand techniques often result in suboptimal resection margins, excessive blood loss, and compromised lumbopelvic stability. This study evaluated whether patient-specific three-dimensional (3D)-printed guiding templates improve surgical accuracy and perioperative outcomes in sacral tumor resection and reconstruction. METHODS: Nineteen patients undergoing en bloc sacral tumor resection (S1-S3 involvement) with spinopelvic reconstruction (2006-2020) were retrospectively analyzed. Patients were divided into a 3D-printing group (n&#x2009;=&#x2009;10) and a conventional freehand group (n&#x2009;=&#x2009;9). In the 3D-printing group, computer-aided design and 3D-printed templates were used for osteotomy, screw placement, and defect reconstruction. Perioperative metrics, surgical accuracy, and complications were compared between groups using Welch's t-test and the Hodges-Lehmann method; oncologic events during follow-up were recorded descriptively. RESULTS: The 3D-printing group demonstrated significantly shorter operative time (456.5&#x2009;&#xb1;&#x2009;62.36 vs. 574.44&#x2009;&#xb1;&#x2009;114.58&#x2009;min, p&#x2009;=&#x2009;0.012), reduced blood loss (4081.40&#x2009;&#xb1;&#x2009;838.99 vs. 5090.0&#x2009;&#xb1;&#x2009;1059.67&#x2009;mL, p&#x2009;=&#x2009;0.034), and fewer fluoroscopic exposures (4.2&#x2009;&#xb1;&#x2009;0.79 vs. 10.0&#x2009;&#xb1;&#x2009;1.58, p&#x2009;<&#x2009;0.001) compared with the conventional group. Osteotomy accuracy was also superior in the 3D-printing group, with significantly lower angular deviation (3.33&#xb0;&#x2009;&#xb1;&#x2009;0.45&#xb0; vs. 6.79&#xb0;&#x2009;&#xb1;&#x2009;2.16&#xb0;, p&#x2009;=&#x2009;0.0012). Postoperative complication rates were comparable (30% vs. 44.4%, p&#x2009;=&#x2009;0.649), but hospital stay was significantly shorter in the 3D-printing group (10.7&#x2009;&#xb1;&#x2009;2.71 vs. 18.11&#x2009;&#xb1;&#x2009;4.01&#x2009;days, p&#x2009;<&#x2009;0.001). CONCLUSION: Patient-specific 3D-printed guiding templates enhance precision in sacral tumor excision and reconstruction, improving surgical efficiency and perioperative safety. This computer-assisted, template-guided approach represents a valuable advancement for complex sacral oncologic surgery.

Humans

Recovering membrane interaction kinetics of single molecules from 3D tracking data.

Interactions between cytosolic biomolecules and the bacterial inner membrane are fundamental to many cellular processes, yet directly measuring their binding kinetics in living cells remains challenging. Conventional 2D single-molecule tracking analyses can be insufficient, particularly when membrane association does not markedly alter the diffusion rate. Here, we present a method to recover membrane interaction kinetics from 3D single-molecule trajectories in rod-shaped bacteria. Using simulated 3D tracking data, we identify membrane-associated motion by quantifying how well short trajectory segments follow the circular curvature of the cell membrane. The resulting measure is further analyzed using a hidden Markov modeling framework, enabling robust discrimination between cytosolic and membrane-bound states and capturing the dynamics of state transitions without requiring diffusion-rate changes or direct colocalization with membrane markers. This work establishes a general framework for extracting membrane interaction kinetics from 3D single-molecule tracking data in live bacteria and highlights the value of realistic microscopy simulations for quantitative interpretation and systematic bias assessment.

Kinetics

Three-Dimensional Fracture Mapping of the Terrible Triad of the Elbow: Morphological Characteristics and Clinical Implications.

BACKGROUND: The morphology of fractures in the terrible triad of the elbow (TTE) is complex, and precise management relies on a profound understanding of this morphology. This study aims to systematically analyze, for the first time, the distribution and morphological characteristics of TTE fracture lines using three-dimensional (3D) imaging technology. METHODS: Clinical data and thin-slice CT scans of 112 patients with TTE from January 2021 to December 2024 were retrospectively included. 3D fracture models were reconstructed using Mimics software. Virtual reduction and standardized alignment were performed using 3-matic software. Fracture lines were mapped onto standard ulnar and radial templates, and 3D fracture heat maps were generated using the E-3D software to demonstrate the high-frequency distribution zones of the fracture lines visually. Statistical analysis was performed using SPSS software (version 21.0, IBM Corp., Armonk, NY, USA). Continuous variables were compared using one-way analysis of variance (ANOVA), and categorical variables were compared using the chi-square test (&#x3c7;2 test). A two-tailed p&#x2009;<&#x2009;0.05 was considered statistically significant. RESULTS: The study revealed distinct patterns in the distribution of TTE fracture lines. In the coronoid process, the fracture "hot zone" presented as an annular high-density band extending from the lateral middle aspect to the tip. In the radial head, an oblique high-density band was observed in the anterolateral quadrant of the articular surface. The radial neck exhibited a circumferential high-density zone, which was most prominent in the anterolateral aspect. Statistical analysis indicated a significant correlation between age and fracture complexity; the proportion of Regan-Morrey type III coronoid fractures and Mason type III radial head fractures was significantly higher in elderly patients (>&#x2009;60&#x2009;years) (p&#x2009;<&#x2009;0.05), suggesting that advanced age is a significant risk factor for complex fractures. CONCLUSION: This study is the first to visually reveal the Collaborative Distribution Patterns of TTE fracture lines using 3D fracture mapping technology. This model provides morphological evidence for understanding the injury mechanism of TTE and offers an anatomical framework that may assist surgeons in individualizing surgical approaches and fixation strategies.

Humans

Which radiographic plane should be used to quantify the distal tibia angle on weightbearing CT images?

BACKGROUND: Precise quantification of distal tibial alignment is essential for planning corrective osteotomies and ankle joint replacement surgery. The lateral distal tibial angle (LDTA) is the principal radiographic parameter used for this purpose. While LDTA is increasingly measured on weightbearing cone-beam CT (WBCT) using two-dimensional coronal slices, the optimal measurement plane remains unclear. METHODS: In this retrospective comparative study, full-leg WBCT scans of patients scheduled for supramalleolar osteotomy (n&#x202f;=&#x202f;20; mean age 47&#x202f;&#xb1;&#x202f;12.8 years) were analyzed. LDTA was measured on three coronal planes of the distal tibial plafond (anterior edge, mid-dome, posterior edge) and compared with semi-automated three-dimensional (3D) tibial alignment measurements as the reference standard. RESULTS: Mid-dome LDTA showed no significant difference from the 3D reference (p&#x202f;>&#x202f;0.05) and demonstrated excellent agreement. Anterior measurements significantly overestimated LDTA, while posterior measurements underestimated it (both p&#x202f;<&#x202f;0.05), with only fair agreement. CONCLUSION: LDTA should be measured at the mid-dome of the distal tibial plafond on WBCT to ensure accurate and reproducible alignment assessment. LEVEL OF EVIDENCE: Level III - Retrospective Comparative Study.

Humans

Screening of Estrogenic and Antiestrogenic Effects of Estradiol, Bisphenol A, and Fulvestrant Using 2D and 3D Breast Cancer Cell Systems With a Luciferase Reporter Gene Assay.

Endocrine-disrupting chemicals (EDCs) like bisphenol A (BPA) pose health risks by interfering with hormones. This study develops and utilizes in&#xa0;vitro 2D and 3D cell models to evaluate the estrogenic and antiestrogenic properties of compounds. Human breast cancer cell lines T47D and MCF7, stably transfected with a luciferase reporter gene (ERE-LUC), were first compared in 2D. Due to the significantly higher sensitivity and responsiveness observed in the T47D line during preliminary 2D screenings, this cell line was exclusively selected for the development of the 3D spheroid model. Cells were treated with 17&#x3b2;-estradiol (E2), BPA, and Fulvestrant (FUL) to assess cell viability and luciferase activity. In 2D models, T47D ERE-LUC cells showed higher responsiveness than MCF7 ERE-LUC, which failed to show significant luciferase induction with E2. In the 3D T47D model, cells exhibited significant and robust changes in luciferase activity in response to E2 and BPA, highlighting the enhanced fidelity of 3D cultures in replicating tissue conditions compared to their 2D counterparts. The study highlights the effectiveness of 3D models over 2D in evaluating estrogenic activity. Specifically, the 3D T47D ERE-LUC system serves as a superior, sensitive, and reliable platform for screening EDCs, offering benefits in cost, data speed, and reduced in&#xa0;vivo reliance.

Humans

Simultaneous determination of imiquimod and terbinafine in skin permeation studies: Validation of a liquid chromatography method with fluorescence detection.

Chromoblastomycosis is a chronic, neglected subcutaneous mycosis posing significant therapeutic challenges. A topical strategy combining terbinafine (TBF), an antifungal, with imiquimod (IMQ), a TLR-7/8 agonist immunomodulator, has emerged a promising alternative. However, no validated analytical method is currently available to simultaneously quantify both drugs in skin, which is crucial for novel formulation development. This study reports the development and validation of a simple HPLC method with fluorescence detection (excitation 236&#xa0;nm, emission 340&#xa0;nm) for the simultaneous determination of TBF and IMQ extracted from porcine skin. Separation was achieved on a C8 reversed-phase column (125&#xa0;&#xd7;&#xa0;4.0&#xa0;mm, 5&#xa0;&#x3bc;m) using a mobile phase of methanol and water (60,40, v/v), both containing 0.1% formic acid at a flow rate of 0.8&#xa0;mL/min. The method showed excellent linearity (r&#xa0;>&#xa0;0.999) over 0.01-1.0&#xa0;&#x3bc;g/mL for IMQ and 0.1-2.0&#xa0;&#x3bc;g/mL for TBF. Intra- and inter-day precision demonstrated coefficients of variation below 5%, and recovery rates from skin (79-105%) confirmed accuracy. Limits of detection were 0.001&#xa0;&#x3bc;g/mL for IMQ and 0.004&#xa0;&#x3bc;g/mL for TBF, with quantification limits of 0.02&#xa0;&#x3bc;g/mL and 0.16&#xa0;&#x3bc;g/mL, respectively. This selective, sensitive, and reproducible method represents a valuable analytical tool for supporting the development and quality control of topical formulations for chromoblastomycosis and other fungal skin diseases.

Animals

Test-retest reliability of spatiotemporal, kinematic, and kinetic measures in marker-based 3D gait analysis: A systematic review.

BACKGROUND: Marker-based 3D gait analysis (3DGA) is widely used to quantify impairments and evaluate treatment effects. For longitudinal clinical interpretation, clinicians and researchers need reference values for inter-session measurement error. For this purpose, this systematic review synthesized Standard Error of Measurement (SEM) values for spatiotemporal, kinematic, and kinetic (moments) outcomes obtained from marker-based 3DGA studies. METHODS: PubMed and Scopus were searched (final search: 11 December 2025). Studies reporting inter-session test-retest SEM and/or MDC for steady-state overground or treadmill walking using marker-based motion capture were included. Two authors screened records and appraised methodological/reporting quality using a custom tool informed by COSMIN, GRRAS, and biomechanics-specific items. Due to heterogeneity, results were synthesized descriptively using study-level median SEM values, stratified by joint, plane, population (healthy, pathological, single subgroups), and walking condition. Minimal Detectable Change (MDC) values were computed for all available data. RESULTS: Thirty-four studies (762 participants, 44.2% females) were included, with substantially more evidence for overground than treadmill walking. Overground spatiotemporal outcomes showed low errors (walking speed SEM of 0.06 m/s; timing typically &#x2264;0.03 s; spatial parameters generally &#x2264;0.03 m). For joint kinematics during overground walking, median SEMs were 2.4&#xb0; (sagittal), 1.9&#xb0; (frontal), and 3.3&#xb0; (transverse). The corresponding joint-kinetic SEMs were approximately 0.06, 0.04, and 0.03 Nm/kg, respectively. Treadmill data followed similar patterns. SIGNIFICANCE: Marker-based 3DGA allows for accurate assessment of spatiotemporal, kinematic, and kinetic gait features. We provided detailed SEM/MDC lookup tables to support clinical decision-making. Results further offer a benchmark for validating emerging gait assessment technologies (e.g., markerless systems) against realistic limits of marker-based 3DGA.

Humans

Three-dimensional source apportionment and quantitative characterization of horizontal and vertical transport fluxes of O3 and its precursors in the Beijing-Tianjin-Hebei region, China.

Persistent surface ozone (O3) pollution in the Beijing-Tianjin-Hebei (BTH) region is driven by coupled precursor emissions and multi-scale transport, yet its altitude-dependent transport and source contributions remain insufficiently quantified. Here we integrated the Weather Research and Forecasting and the Comprehensive Air Quality Model with Extensions with the Ozone Source Apportionment Technology and a quantitative transport-flux framework to characterize three-dimensional source apportionment and horizontal/vertical fluxes of O3, Volatile Organic Compounds&#x200c; (VOCs), and Nitrogen Oxides (NOx) across dynamic meteorological scenarios. Simulations showed that VOCs and NOx were dominated by local emissions near the surface (73.61 %-82.18 %), whereas surface O3 was primarily controlled by regional transport, with local contributions of only 11.01 %-13.75 %. Notably, the transport dominance further strengthened with altitude, exceeding 93 % at 1.8 km. Industrial and transportation emissions together contributed more than 75 % of precursor emissions and account for approximately 80 % of O3 formation, while favorable/unfavorable meteorological years modulated long-range transport efficiency and the vertical distribution of contributions. Horizontal flux analysis highlighted three major pathways (Northwest-Southeast, Southeast-Northwest, and Southwest-Northeast), with Shijiazhuang serving as a critical pollutant "sink" across altitude layers. Vertical fluxes revealed an altitude transition near 600 m: net downward transport dominated below 600 m, whereas enhanced summer convection promoted upward transport above 600 m. These results support altitude-dependent, scenario-specific strategies for coordinated regional O3 mitigation in the BTH region.

Ozone

Systematic evaluation of one-dimensional-to-two-dimensional near-infrared spectroscopy transformations with deep learning for quantifying coconut sap adulteration.

Near-infrared (NIR) spectroscopy have limitations when combined with deep learning (DL) algorithms because they rely on low-dimensional datasets. Therefore, we investigated the potential of transforming one-dimensional (1D) NIR spectra into two-dimensional (2D) spectrograms using synchronous and asynchronous techniques and the continuous wavelet transform (CWT) and their effectiveness by integrating with DL for detecting adulteration in coconut sap. NIR spectra (12,500-4000&#xa0;cm-1) were collected from binary mixtures (0%-100%;w/w). The performance of all DL (convolutional neural networks-CNN, AlexNet and ResNet) models was compared with that of partial least squares (PLS). The models were ranked in the mentioned order based on their performances: 2D-CWT&#xa0;>&#xa0;2D-asynchronous > 2D-synchronous > 1D/2D-PLS. The important features of the best model can be explained and visualized using gradient-weighted-class-activation-mapping. The findings highlight that the 1D-to-2D NIR data transformation combined with DL is a highly robust approach because it addresses the feature representation gap in NIR data and effectively captures the spatial-spectral correlations.

Spectroscopy, Near-Infrared

Fused Deposition Modeling (FDM) of polyether-ether-ketone (PEEK) dental implants: A systematic review of the effect of printing parameters on mechanical behaviour and surface quality.

PURPOSE: This systematic review evaluated how FDM printing parameters influence mechanical behaviour and surface characteristics of 3D-printed PEEK and identified parameter combinations linked to the most favourable mechanical performance and surface quality. MATERIALS AND METHODS: An electronic search was conducted in: MEDLINE (Ovid), PubMed, Embase, Web of Science, Scopus, and Compendex (last update: January 2025). Studies that evaluated the effect of FDM printing parameters on mechanical and surface properties of PEEK were included. Outcomes comprised compressive, tensile, and flexural strengths, elastic modulus, fracture toughness, surface hardness, roughness, and wettability. RESULTS: Of 4005 reports screened, 54 manuscripts were included. 92.6% (n&#x202f;=&#x202f;50) of articles showed low risk-of-bias, while 7.4% (n&#x202f;=&#x202f;4) showed medium risk-of-bias. Tensile strength was the most investigated mechanical parameter (78%), followed by elastic modulus (41%), flexural strength (30%), compressive strength (20%), and fracture toughness (6%). Surface roughness was the most evaluated surface property (30%), followed by hardness (17%) and wettability (6%). Across studies, higher printing temperatures, lower printing speed, thinner layer thickness, and maximum infill ratio in a horizontal printing orientation were associated with higher strengths, less warpage, increased accuracy, and improved surface quality. CONCLUSION: Specific combinations of FDM printing parameters can significantly improve the mechanical and surface properties of PEEK. However, it is difficult to meet all the optimal conditions simultaneously. Thus, balancing between different parameters must be considered in practical production.

Benzophenones

Three-dimensional porous nano-hydroxyapatite@gelatin composite as efficient adsorbent for uranyl ion removal from low-level radioactive wastewater.

The contamination of water resources by uranyl (UO22+) ions poses significant environmental and health risks, requiring the development of efficient and sustainable remediation strategies. Adsorption-based techniques have emerged as promising approaches in the field of UO22+ removal, but the design of cost-effective, high-capacity, and environmentally friendly adsorbents remains challenging. In this study, a three-dimensional porous nano-hydroxyapatite@gelatin (nHAP@Ge) composite was synthesized through glutaraldehyde cross-linking, combining the structural stability of Ge with the high uranium affinity of nHAP. The optimized nHAP@Ge, with a nHAP:Ge mass ratio of 1:0.5, exhibited exceptional UO22+ removal efficiency (97 %), along with high adsorption capacity (364.03 mg/g). Systematic characterizations using scanning electron microscopy (SEM), thermogravimetric analysis (TGA), Fourier transform infrared (FT-IR) spectroscopy, and X-ray photoelectron spectroscopy (XPS) methods revealed that the porous structure and surface functional groups (-OH, Ca2+, and PO43-) of the material synergistically contributed to binding UO22+ species. Furthermore, the incorporation of nHAP into the Ge framework resulted in enhanced thermal stability while significantly improving the UO22+ adsorption performance. This work presents a scalable, eco-friendly, and recyclable strategy for the effective treatment of uranium-contaminated water, with potential applications in nuclear wastewater treatment and environmental remediation.

Adsorption

Exploring the Diagnostic Utility of Ferumoxytol for Brachial Plexus MR Neurography.

Background Ferumoxytol has been described as an alternative contrast agent for vascular suppression in MR neurography (MRN), but its diagnostic utility in patients has yet to be evaluated. Purpose To evaluate the impact of ferumoxytol on vascular suppression, nerve conspicuity, and evaluation of nerve abnormalities at three-dimensional (3D) brachial plexus MRN, compared with noncontrast and gadolinium-enhanced MRN, in participants with suspected Parsonage-Turner syndrome (PTS) or thoracic outlet syndrome (TOS). Materials and Methods This prospective study included participants who underwent 3D MRN with and/or without gadolinium chelate for clinical suspicion of PTS or TOS and subsequently underwent 3D MRN with ferumoxytol (within 3 months of the clinical examination). Two musculoskeletal radiologists qualitatively evaluated 3D short-tau inversion-recovery fast spin-echo scans for the degree of vascular suppression, nerve conspicuity, and presence of nerve abnormalities. Wilcoxon signed-rank or McNemar tests were used for comparing noncontrast and gadolinium-enhanced scans with ferumoxytol-enhanced scans. Results This study included 18 participants (mean age, 42 years &#xb1; 15.2 [SD]; 10 men). Ferumoxytol-enhanced scans demonstrated improved vascular suppression compared with both noncontrast scans (both raters, P < .001) and gadolinium-enhanced scans (both P = .04). For rater 2, ferumoxytol-enhanced acquisitions demonstrated improved conspicuity of several nerve segments relative to the noncontrast scan, including segments of the suprascapular (P = .01), axillary (P = .02), and long thoracic nerves (P = .004). The distribution of scores for these nerve segments for rater 1 also favored ferumoxytol-enhanced versus noncontrast scans, but the differences were not statistically significant (all P &#x2265; .06). There was no evidence of a difference in nerve conspicuity between ferumoxytol-enhanced and gadolinium-enhanced scans (P &#x2265; .17 for all nerve segments) and also no evidence of discrepancies in abnormal nerve findings between the acquisitions (all P &#x2265; .48). Conclusion Ferumoxytol improved vascular suppression compared with noncontrast and gadolinium-enhanced 3D short-tau inversion-recovery fast spin-echo sequences in brachial plexus MRN, enhancing the conspicuity of several nerve branches versus noncontrast scans, with similar detection of abnormal nerve findings. &#xa9; RSNA, 2026 Supplemental material is available for this article.

Humans

Comfort and Usability of Digital Versus Conventional Custom-Fit Mouthguards: A Randomized Clinical Trial.

BACKGROUND/OBJECTIVES: The use of mouthguards protects teeth and the supporting tissues against impacts. Digital impressions and 3D-printed models can reduce manufacturing steps and minimize discomfort. This study evaluated the fit, comfort, and usability of custom-made mouthguards, obtained by conventional and digital workflow, in amateur athletes. MATERIALS AND METHODS: Amateur athletes were recruited for this randomized, double-blind, crossover clinical study. Each participant received two 4-mm-thick custom-fit mouthguards made of ethylene vinyl acetate (EVA) sheets using two protocols: conventional impression using alginate to produce dental stone cast (CMP) and intraoral digital scanning to produce 3D-printed resin models (DMP). Each mouthguard was worn during all training and matches over 3&#x2009;months. The order of mouthguard use was randomly assigned. Patient satisfaction with the impression protocol and mouthguard use, model accuracy, and mouthguard fit were assessed. RESULTS: Overall, 46 participants completed the study. The DMP protocol required less execution time (p&#x2009;=&#x2009;0.023), caused less discomfort (p&#x2009;=&#x2009;0.018), anxiety (p&#x2009;=&#x2009;0.008), nausea (p&#x2009;=&#x2009;0.027), difficulty breathing (p&#x2009;<&#x2009;0.001), and unpleasant taste (p&#x2009;=&#x2009;0.006) compared to the CMP protocol. The pain (p&#x2009;=&#x2009;0.971) perceived by the participants was similar in both impression protocols. The CMP-mouthguards were considered to be better fitting by the majority of participants (p&#x2009;=&#x2009;0.027). Between-group comparisons revealed that DMP-mouthguard caused less discomfort immediately postadaptation (p&#x2009;=&#x2009;0.034), with no significant differences observed at 30 or 90&#x2009;days. CONCLUSIONS: The digital workflow demonstrated to be efficient in the fabrication of mouthguards. Digital impression was more comfortable, requiring less execution time, with more accurate printed models and produced mouthguards with reported comfort and fit levels similar to those manufactured conventionally.

Humans

Recent advances in supramolecular macrocycle-based artificial light-harvesting systems.

Artificial light-harvesting systems (ALHSs) inspired by the antenna function of natural photosynthesis provide molecular platforms for collecting excitation energy and directing it to emissive or reactive acceptors. In many supramolecular ALHSs, however, practical performance is limited by poorly defined donor-acceptor orientation, aggregation-caused quenching (ACQ), interfacial defects, and limited stability in aqueous or complex media. Supramolecular macrocycles-particularly pillar[n]arenes (PAs), cucurbit[n]urils (CBs), calixarenes (CAs), cyclodextrins (CDs), and supramolecular coordination complexes (SCCs)-offer a useful design space because their cavities, pre-organized scaffolds, and reversible non-covalent interactions can confine chromophores, tune local donor/acceptor ratios, and modulate F&#xf6;rster resonance energy transfer (FRET). This Review systematically examines the unique structural advantages and assembly mechanisms of the five macrocyclic families, with an emphasis on their use in constructing ALHSs-from single-step to cascaded FRET-and in advancing aqueous photocatalysis, near-infrared bioimaging, panchromatic fluorescence modulation, and singlet oxygen generation. The resulting structure-property-application framework is intended to guide the rational design of macrocycle-assisted photofunctional materials while avoiding overextension of the photosynthesis analogy.

Journal Article

Retrosigmoid craniotomy surgical guide: The way forward for precise exposure of the transverse-sigmoid sinuses.

INTRODUCTION: The retrosigmoid craniotomy is the workhorse approach to the cerebellopontine angle. Accurate localisation of the transverse-sigmoid junction (TSJ) is key for optimised exposure and cerebellar retraction. Various methods, both anatomical and navigational, have been used but with suboptimal results. We utilised a 3D-printed retrosigmoid surgical guide in an attempt to overcome this and report our early outcomes and experiences in the design, production and utilisation of the guide. METHODS: This is a prospective cohort study of the patients with retrosigmoid craniotomies performed using the surgical guides. Patient demographics and diagnoses, along with the accuracy of the planned burrhole and craniotomy, need for craniotomy extension, presence of venous sinus injury, set-up time, and cost were reported. RESULTS: There were ten cerebellopontine angle cases in which the surgical guides were utilised, three petrous meningiomas, two trigeminal neuralgias, two metastasis, and three other tumours. The planned burrhole and craniotomy were precise in all cases with accurate exposure of the TSJ and no requirement for craniotomy extension. The mean set up time was 3.9&#xa0;min, and the mean cost of the surgical guides was USD 470.90. One elderly patient had an intraoperative transverse sinus injury related to adherent dura that was planned for exposure. CONCLUSION: The 3D-printed surgical guide is a potential solution to the rapid, precise and consistent identification of the TSJ when performing a retrosigmoid craniotomy. We present our early experience and discuss nuances in the designing, production, and intraoperative phases to optimise the precision of this guide. We suggest two methods to avoid sinus injury in elderly patients: either to plan the craniotomy to the edge of the sinus, or to plan sinus exposure but to use burr drills rather than the osteotome, as in our case, to expose the sinus.

Humans