Search PubMedSearch

SEARCH · Search PubMed

Results for “Photon counting CT”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

108 recordsLinked to original sources

Photon-counting detector computed tomography (PCD-CT) in multiple myeloma: a systematic review and trial sequential meta-analysis on image quality and radiation dose.

OBJECTIVES: To systematically review and perform a meta-analysis comparing the effects of PCD-CT versus EID-CT on image quality (sharpness) and radiation dose (CTDIvol) in patients with bone lesions due to multiple myeloma&#xa0;(MM). METHODS: A comprehensive search of PubMed, Embase, Scopus, and Cochrane Central was conducted from inception to October 2025. Studies comparing PCD-CT and EID-CT in MM patients were included. Methodological quality was assessed using ROBINS-I, and the certainty of evidence was assessed using GRADE. RESULTS: A total of 41 studies were identified that matched our search criteria. After duplicate removal and screening, five studies (n = 170 patients) were included in the systematic review, with four contributing to the meta-analysis. PCD-CT showed a significant pooled mean difference in image sharpness (mean difference, + 0.99 points; 95% CI, 0.62-1.37; p < 0.001). PCD-CT also demonstrated a reduction in radiation dose (mean difference, -4.95 milligrays; 95% CI, -8.39 to -1.50; p = 0.005). Trial sequential analysis (TSA) confirmed stability of pooled estimates, with conclusive evidence for image sharpness improvement, and suggestive yet incomplete evidence for radiation dose reduction. CONCLUSION: Compared to EID-CT in MM, PCD-CT significantly improves subjective image sharpness as supported by trial sequential analysis. Conventional meta-analysis suggested a reduction in radiation dose with PCD-CT; however, trial sequential analysis indicated that the cumulative evidence remains inconclusive. Further large-scale studies are suggested to confirm the magnitude of the radiation dose reduction benefit.

Humans

Performance of Photon-counting CT for Assessing Pretreatment Breast Cancer: Comparison with Mammography, MRI, and 18F-FDG PET/CT.

Background Photon-counting CT (PCCT) offers improved spatial resolution, contrast to noise ratio, and dose efficiency, but its clinical utility remains incompletely defined for breast cancer. Purpose To evaluate the feasibility of PCCT for pretreatment breast cancer assessment through comparisons with MRI, full-field digital mammography (FFDM), and fluorine 18 (18F) fluorodeoxyglucose (FDG) PET/CT. Materials and Methods In this prospective study (March-May 2025), female participants with breast lesions categorized as Breast Imaging Reporting and Data System 4C or higher at US or FFDM underwent breast MRI and multiphasic contrast-enhanced PCCT. 18F-FDG PET/CT was performed in a subset with locally advanced disease. Four radiologists independently evaluated lesion morphologic characteristics, additional findings, and clinical TNM stage. Agreement was analyzed using intraclass correlation coefficients (ICCs) and &#x3ba; statistics. The diagnostic performance for additional lesions and nodal metastasis was compared with the reference standard (pathologic examination). Results Among 126 participants (mean age, 58.1 years &#xb1; 12.3 [SD]), interreader agreement across PCCT, MRI, and FFDM was good to excellent. PCCT agreed with MRI for lesion characterization (&#x3ba; = 0.57-0.96) and clinical T categorization (&#x3ba; = 0.86-0.88), with highest agreement with pathologic size (ICC, 0.70-0.81). For 46 pathologically confirmed additional lesions, PCCT was more sensitive than FFDM (difference, 44% [95% CI: 19, 66]) and similar to MRI (difference, 7% [95% CI: -5, 21]). Additionally, 44% (95% CI: 27, 52) of microcalcifications were missed at PCCT versus FFDM. For pathologically confirmed nodal metastasis, PCCT was more sensitive (difference, 10% [95% CI: 1, 20]) and accurate (difference, 6% [95% CI: 1, 11]) than MRI. For clinical N category, PCCT agreed with PET/CT (&#x3ba; = 0.82 [95% CI: 0.62, 0.96]; n = 19). Two distant metastases identified at PCCT were consistent with 18F-FDG PET/CT and pathologic findings. Conclusion PCCT demonstrated similar performance to MRI for lesion characterization and detection of additional lesions, with better performance for nodal metastasis evaluation; however, detection of microcalcifications was limited. &#xa9; RSNA, 2026 Supplemental material is available for this article.

Humans

An automated geometric modeling framework in GATE for the design and optimization of high-sensitivity converging-beam SPECT collimators.

Objective.The trade-off between detection sensitivity and spatial resolution is a fundamental challenge in designing organ-dedicated Single-photon emission computed tomography (SPECT) collimators. While converging-hole geometries offer a solution, their optimization is often hindered by the lack of flexible computational tools capable of modeling large-scale, non-parallel hole arrays. This study aims to develop an automated geometric modeling framework to facilitate the design and evaluation of complex converging- and diverging-hole collimators within standard Monte Carlo environments.Approach.We developed a specialized modeling framework by implementing custom C++ classes and a vector-based alignment algorithm within GATE. This platform enables automated, orientation-consistent construction of large-scale converging arrays not natively supported by standard implementations. A high-sensitivity pure cone-beam collimator (CBC) was designed using this framework. The evaluation used hot-rod, disc, and Jaszczak phantoms for physical characterization, while XCAT and dedicated brain models were employed for clinical tasks, including cardiac, brain perfusion, and DaTscan SPECT simulations.Main results.The CBC achieved a nearly fourfold sensitivity increase compared to a conventional low-energy high-resolution parallel-hole collimator at a 20 cm radius of rotation, while maintaining comparable spatial resolution. Despite a 52.3% field of view reduction, the CBC yielded a 2.2-fold noise reduction (CV: 11.7% vs 25.9%) and mitigated partial volume effects via geometric magnification. XCAT and brain phantom simulations confirmed enhanced anatomical definition and contrast recovery in cardiac, perfusion, and DaTscan tasks.Significance.This work provides an efficient computational tool for rapid design space exploration of advanced collimator geometries. The results demonstrate that the proposed CBC design offers a significant sensitivity advantage, making it highly suitable for high-performance, small-volume clinical applications such as brain and cardiac molecular imaging.

Tomography, Emission-Computed, Single-Photon

Axial Length Adjustment and AL/R Ratio Optimization of IOL Power Calculation in Extremely Long Eyes.

PURPOSE: To evaluate the accuracy of modern intraocular lens (IOL) power calculation formulas and axial length (AL) adjustment methods in eyes with AL &#x2265; 30.0 mm. DESIGN: Retrospective consecutive cross-sectional study. PARTICIPANTS AND CONTROLS: A total of 308 eyes (308 patients) with AL &#x2265; 30.00 mm were included. METHODS: Accuracy of modern online formulas, alone or with established AL adjustments methods, was analyzed. Subgroup analyses were performed based on AL, keratometry (K), anterior chamber depth (ACD), lens thickness (LT), and AL-to-corneal radius (AL/R) ratio. MAIN OUTCOME MEASURES: Predictive accuracy was evaluated using the formula performance index (FPI), root mean square absolute prediction error (RMSAE), standard deviation (SD) of prediction error (PE), and percentage of eyes within &#xb1;0.25 and &#xb1;0.50 diopters (D). RESULTS: Overall, Holladay 1 combined with the nonlinear polynomial Wang-Koch axial length adjustment (H1-PWK) demonstrated the best overall performance, achieving the lowest SD (0.40), RMSAE (0.40), and highest FPI (0.494). A tendency toward hyperopic error was observed in eyes with AL &#x2265; 32.0 mm, K &#x2265; 46.0 D. The AL/R ratio showed a significant positive correlation with PE in the Ladas Super formula, Barrett Universal II, EVO, PEARL-DGS, and Hoffer QST formulas. Spline-based regression analysis indicated that the transition point of AL/R from myopic to hyperopic PE varied across different formulas. CONCLUSIONS: H1-PWK provides robust refractive accuracy in extremely long eyes. The AL/R ratio may provide a useful composite biometric stratification parameter compared to AL alone.

Humans

Responsiveness of muscle mass gain to different load intensities of resistance training in older women: A randomized crossover study.

BACKGROUND: Aging is associated with progressive declines in skeletal muscle mass (SMM) and substantial interindividual variability in adaptations to resistance training (RT). However, whether training load intensity influences hypertrophic responsiveness in older adults remains unclear. OBJECTIVE: To investigate the effects of two commonly prescribed RT loading schemes (15RM and 10RM) on estimated SMM adaptations and responsiveness in older women. METHODS: Twenty-seven older women (67.7&#xa0;&#xb1;&#xa0;4.9&#xa0;years; 65.7&#xa0;&#xb1;&#xa0;10.6&#xa0;kg; 154.5&#xa0;&#xb1;&#xa0;5.8&#xa0;cm) completed two 8-week RT interventions performed at 15RM and 10RM in a randomized crossover design, separated by a 12-week detraining period. Estimated SMM was assessed using dual-energy X-ray absorptiometry. Responsiveness was operationally defined using the standard error of measurement, and participants were classified as responders (RP) or non-responders (N-RP) according to changes in estimated SMM. RESULTS: Both loading schemes promoted significant and comparable increases in estimated SMM (15RM: +0.62&#xa0;&#xb1;&#xa0;0.4&#xa0;kg vs. 10RM: +0.43&#xa0;&#xb1;&#xa0;0.3&#xa0;kg). Overall, 61.1% of participants were classified as responders in at least one condition, whereas 38.9% were classified as non-responders. Responsiveness status was consistent across conditions for most participants, with 48.1% classified as responders under both loading schemes and 25.9% as non-responders under both conditions. Only seven participants (25.9%) changed responsiveness status between interventions. No clear pattern indicated a greater likelihood of responsiveness with either loading scheme. CONCLUSIONS: Results suggest that both the 10RM and 15RM RT protocols significantly increase estimated SMM in older women, with no significant differences between training conditions. Although substantial interindividual variability in adaptive responses exists, training load intensity does not appear to meaningfully influence responsiveness status in most individuals. These findings suggest that both loading schemes can be effectively prescribed to promote SMM gains in older women.

Aged

Bacterial Lysates Add-On Therapy to Reduce Postoperative Recurrence in Nasal Polyps.

OBJECTIVE: This study aimed to investigate the potential role of OM-85 in reducing polyp recurrence (PR). METHODS: A single-center randomized, prospective study was performed to compare the inter-group PR rate, patient-reported outcome measures (PROMs), CT and endoscopic scores. Hundred patients were randomized to receive either add-on OM-85 (34/50) or control group (43/50); 77 participants completed the 12-month follow-up. The OM-85 group received oral treatment for 10&#x2009;days, followed by a 20-day washout (Months 1-3 and 7-9). Primary outcome was the PR rate. Secondary outcomes included PROMs, Lund-Kennedy (L-K) scores, Lund-Mackay (L-M) scores, and complete blood count (CBC) parameters. RESULTS: The PR rate was significantly lower in the OM-85 group (8.82%) than in the control group (27.91%, &#x3c7; 2&#x2009;=&#x2009;4.408, p&#x2009;=&#x2009;0.036). Univariable analysis identified pre-operative Lund-Mackay (L-M) score (p&#x2009;=&#x2009;0.008) and hyposmia VAS score (p&#x2009;=&#x2009;0.031) as significant predictors of PR. In multivariable analysis, the L-M score remained an independent predictor (OR&#x2009;=&#x2009;1.15, p&#x2009;=&#x2009;0.012), with an optimal cutoff of 10. The OM-85 group showed significant improvements in nasal obstruction, olfactory dysfunction, and mucopurulent discharge at 6 and 12&#x2009;months (p&#x2009;<&#x2009;0.05). Lund-Kennedy (L-K) score and 22-item Sinonasal Outcome Test (SNOT-22) score were also significantly improved (p&#x2009;<&#x2009;0.05). Furthermore, the OM-85 group exhibited elevated white blood cell counts and lymphocyte percentages from 6&#x2009;months onward (p&#x2009;<&#x2009;0.05). CONCLUSION: Adjuvant OM-85 may reduce postoperative PR, with improved endoscopic and symptom scores, potentially mediated by enhanced systemic immune function.

Humans

A reanalysis of the Hitachi cohort study evaluating the effectiveness of low-dose CT screening for lung cancer.

The effectiveness of low-dose thoracic computed tomography (CT) screening for lung cancer for non-smokers or light smokers has been unclear. The results of the Hitachi cohort study performed by the conventional multivariable analysis suggested the reduction of lung cancer mortality by thoracic CT screening, but also revealed the lower all-cause mortality in the CT group, which indicated the existence of self-selection bias. Because the background of the subjects in the CT screening group and that in the X-ray screening group were very different, it is critical to adjust appropriately the confounding factors. In this brief report, we describe a re-evaluation of the results of the Hitachi Cohort Study performed by using more flexible methods, propensity score matching and inverse probability weighting.

epidemiology/public health

From buffalo to human: Klebsiella pneumoniae in high-somatic cell count milk as an overlooked link in the one health chain.

High somatic cell count (SCC) is a critical indicator of udder health and milk quality in buffalo milk production. However, in many low-income regions, SCC monitoring is often underemphasized, allowing a proportion of high-SCC buffalo milk to enter the food chain and potentially compromising food safety and public health. Klebsiella pneumoniae (K. pneumoniae) is a common zoonotic pathogen found in high-SCC milk, yet systematic investigations into the prevalence and characteristics in high-SCC buffalo milk remain limited. In this study, 23 K. pneumoniae strains were screened out from 460 bacterial isolates obtained from high-SCC buffalo milk samples from Guangxi, China, with an isolation rate of 5.0%. These isolates were comprehensively characterized using whole-genome sequencing and comparative genomic analyses. The results revealed that 78.26% (18/23) of the isolates shared high genomic similarity with the human reference strain ATCC 13883, and the ST37 clone exhibited a pronounced potential of cross-species transmission. All isolates harbored core adhesion factors and intrinsic resistance genes. Notably, several strains displayed high-risk features: strain 419 carried the K1 capsular serotype, strain 326 possessed a complete yersiniabactin synthesis gene cluster, and strain 320 exhibited a multidrug-resistant phenotype. Phenotypic assays further demonstrated a positive correlation between biofilm formation capacity and virulence in Galleria mellonella. Metabolic pathway enrichment analyses suggested that K. pneumoniae has undergone substantial adaptation to the nutrient-rich buffalo milk environment. Collectively, these findings confirm that raw high-SCC buffalo milk serves as a significant reservoir for high-risk zoonotic K. pneumoniae. While industrial thermal processing effectively eliminates viable pathogens, the resilient antimicrobial resistance determinants within these isolates pose a persistent risk of horizontal gene dissemination along the food chain, providing critical evidence for enhancing pre-processing milk quality regulations within a One Health framework.

Animals

Robotic Needle Insertion for CT-guided Percutaneous Biopsy of Thoracoabdominal Lesions: A Prospective Multicenter Randomized Trial.

Purpose To compare safety and feasibility between a novel CT-guided robotic system and the conventional freehand technique for puncture biopsy of thoracoabdominal lesions. Materials and Methods In this prospective multicenter randomized trial, individuals with suspected lesions were enrolled between July 2023 and April 2024 across three university teaching hospitals and randomized to the robot-assisted group (n = 82) or the freehand group (n = 83). Procedure outcomes included the technical success rate, targeting error, number of CT scans and needle adjustments, puncture time, and complications. Descriptive and inferential statistics were calculated. Results A total of 165 participants (mean age, 60 years &#xb1; 10 [SD]; 83 male) were included. Compared with the freehand group, the robot-assisted group demonstrated a higher technical success rate (97.56% [80 of 82] vs 62.65% [52 of 83], P < .001), lower targeting error (mean Euclidean deviation: 1.7 mm &#xb1; 1.1 vs 4.5 mm &#xb1; 3.9, P < .001), and fewer CT scans (mean, 4.3 &#xb1; 1.9 vs 5.2 &#xb1; 2.3; P = .002) and needle adjustments (mean, 0.7 &#xb1; 0.7 vs 1.6 &#xb1; 1.6; P = .003). Despite differences in geometric precision, both groups achieved 100% (82 of 82 and 83 of 83) diagnostic yield. The median puncture time was comparable between groups (5.5 minutes &#xb1; 4.3 vs 4.8 minutes &#xb1; 7.0, P = .50). During lung biopsies, the robot-assisted approach yielded fewer complications compared with the freehand approach (4.88% [four of 82] vs 16.87% [14 of 83], P = .014). Conclusion Compared with the freehand approach, robot-assisted biopsy yielded greater precision and reduced adjustments and complications while demonstrating noninferior diagnostic efficacy and comparable duration. Keywords: Robotic Needle Insertion, Biopsy, Thoracoabdominal Lesions, Robot-assisted Biopsy, CT-guided Intervention, Percutaneous Needle Biopsy, Randomized Controlled Trial, Algorithm Development, CT, Clinical Testing, Interventional-Body, Biopsy/Needle Aspiration, Percutaneous, Thorax, Abdomen/GI, Liver, Lung, Kidney &#xa9;RSNA, 2026.

Humans

Mechanisms of high-humidity hot air impingement blanching (HHAIB) on microbial counts, functional properties, phenolic profile transformation, and volatile compounds in celery stalks (Apium graveolens L.).

In this study, celery stalks were pretreated with different durations (0-150&#xa0;s) of high-humidity hot air impingement blanching (HHAIB), followed by far-infrared radiation assisted pulsed vacuum freeze-drying (FIR-PVFD) at 60, 65, and 70&#xa0;&#xb0;C. The effects of HHAIB on the physicochemical properties, composition and transformation of phenolic compounds, volatile components, and antioxidant capacity of FIR-PVFD-dried celery stalks were systematically investigated. The results showed that HHAIB not only effectively reduced the counts of total mesophilic aerobic bacteria (TMAB) and total yeast and mold (TYM), but also decreased the relative activities of polyphenol oxidase (PPO) and lipoxygenase (LOX) by more than 91% after 90&#xa0;s of treatment. HHAIB altered the cellular structure of celery stalks, shortened the drying time by 29.33-41.43%, and improved their hydration properties. HHAIB pretreatment promoted the conversion of bound phenolics to free phenolics in celery stalks, with significant increases in the contents of p-coumaric acid, apigenin, graveobioside A, and other components. The total free phenolic content increased by 56.99%, thus HHAIB enhanced the antioxidant activity. An electronic nose and sensory evaluation revealed that HHAIB-pretreated celery stalks better retained the characteristic herbal and pungent notes. GC-MS results indicated that HHAIB treatment optimized the aroma profile by regulating the contents and composition of terpenes, aldehydes, ketones, alcohols, and aromatic compounds.

Apium

Discrepancies in CPAK classification between CT and long-leg radiography: a systematic review and meta-analysis.

OBJECTIVE: To determine whether substantial differences in coronal plane alignment of the knee phenotype distribution, as well as systematic angular measurement discrepancies, exist between CT and long-leg radiography. MATERIALS AND METHODS: From February 2021 to April 2025, we searched PubMed, Embase, and the Cochrane Central Register of Controlled Trials for studies comparing CT- and long-leg radiography-derived coronal plane alignment classifications of the knee in patients with osteoarthritis. The primary outcome was distribution of coronal plane alignment phenotypes. Secondary outcomes included differences in medial proximal tibial angle, lateral distal femoral angle, arithmetic hip-knee-ankle angle, and joint line obliquity. RESULTS: Four studies (1,134 knees) were included. Compared with long-leg radiography-derived classification, CT-derived classification increased type I phenotypes (risk difference: 0.10; 95% confidence interval: 0.01-0.20; P&#x2009;=&#x2009;0.040) and decreased type III (risk difference: -0.04; 95% confidence interval: -0.07 to -0.01; P&#x2009;=&#x2009;0.020) and type V phenotypes (risk difference: -0.04; 95% confidence interval: -0.07 to -0.01; P&#x2009;=&#x2009;0.004). CT yielded significantly lower medial proximal tibial angle (weighted mean difference:&#x2009;-&#x2009;1.18&#xb0;; P&#x2009;<&#x2009;0.001), arithmetic hip-knee-ankle angle (weighted mean difference:&#x2009;-&#x2009;0.95&#xb0;; P&#x2009;<&#x2009;0.001), and joint line obliquity (weighted mean difference:&#x2009;-&#x2009;1.40&#xb0;; P&#x2009;<&#x2009;0.001) than long-leg radiography. Heterogeneity was high for type I phenotype (I2&#x2009;=&#x2009;81%), lateral distal femoral angle (I2&#x2009;=&#x2009;70%), and joint line obliquity (I2&#x2009;=&#x2009;69%). CONCLUSION: Discrepancies between CT-based software-generated and long-leg radiography-derived measurements substantially affect coronal plane alignment classification and angular parameters. Surgeons should consider these modality-specific variations and employ compensatory verification strategies to ensure optimal alignment.

Humans

Which radiographic plane should be used to quantify the distal tibia angle on weightbearing CT images?

BACKGROUND: Precise quantification of distal tibial alignment is essential for planning corrective osteotomies and ankle joint replacement surgery. The lateral distal tibial angle (LDTA) is the principal radiographic parameter used for this purpose. While LDTA is increasingly measured on weightbearing cone-beam CT (WBCT) using two-dimensional coronal slices, the optimal measurement plane remains unclear. METHODS: In this retrospective comparative study, full-leg WBCT scans of patients scheduled for supramalleolar osteotomy (n&#x202f;=&#x202f;20; mean age 47&#x202f;&#xb1;&#x202f;12.8 years) were analyzed. LDTA was measured on three coronal planes of the distal tibial plafond (anterior edge, mid-dome, posterior edge) and compared with semi-automated three-dimensional (3D) tibial alignment measurements as the reference standard. RESULTS: Mid-dome LDTA showed no significant difference from the 3D reference (p&#x202f;>&#x202f;0.05) and demonstrated excellent agreement. Anterior measurements significantly overestimated LDTA, while posterior measurements underestimated it (both p&#x202f;<&#x202f;0.05), with only fair agreement. CONCLUSION: LDTA should be measured at the mid-dome of the distal tibial plafond on WBCT to ensure accurate and reproducible alignment assessment. LEVEL OF EVIDENCE: Level III - Retrospective Comparative Study.

Humans

Impact of Commercial Artificial Intelligence on Radiologist Reading Time for Pulmonary Nodule Evaluation at Chest CT.

Background Chest CT is a primary method for identifying pulmonary nodules, yet interpreting scans remains time-intensive and demanding. Currently, artificial intelligence (AI) is expected to reduce reading times, but the effect of AI on reporting times in this setting is unknown. Purpose To evaluate the impact of a commercial AI software on radiologists' reading time for pulmonary nodule assessment on chest CT scans within a real-world clinical setting. Materials and Methods This retrospective study included patients who underwent chest CT examinations at a tertiary medical center between September 2021 and May 2024. The study period was divided into pre- and post-AI phases. The primary outcome was radiology reporting time. The association between AI implementation and reporting time was evaluated using a multivariable parametric Weibull shared frailty survival model adjusted for reader function, examination type, patient location, and requesting specialty, with clustering at the radiologist level. Interaction analyses assessed heterogeneity across prespecified subgroups. An exploratory extrapolation estimated projected workforce and financial impact. Results This study included 19&#x2009;433 patients (mean age, 62 years &#xb1; 14.2 [SD]; 21&#x2009;814 men; 39&#x2009;323 chest CT examinations, 19&#x2009;190 pre-AI, and 20&#x2009;133 post-AI). AI implementation was associated with faster report completion (adjusted hazard ratio, 1.17; 95% CI: 1.14, 1.21; P < .001). The adjusted median reporting time decreased from 21.3 minutes pre-AI to 18.2 minutes post-AI (14.6% reduction; P < .001). Heterogeneity was observed across reader function (P < .001), examination type (P = .048), and requesting specialty (P = .03). The largest relative reductions were observed for CT thorax electrocardiogram-gated examinations (-41.1%; P < .001) and thoracic radiologists (-25.0%; P < .001), whereas emergency department examinations showed increased median reporting time (7.1%; P < .001). At institutional scan volumes (approximately 20&#x2009;000-22&#x2009;000 chest CT examinations annually), exploratory modeling suggested an approximate reduction of 0.5 full-time equivalent radiologist workload. Conclusion Implementation of commercial AI-assisted pulmonary nodule assessment on chest CT scans reduced radiologist reporting time in a real-world clinical setting. &#xa9; The Author(s) 2026. Published by the Radiological Society of North America under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Iwasawa in this issue.

Humans

Stage shift, histological differentiation, and survival patterns of lung squamous cell carcinoma versus adenocarcinoma in low-dose CT screening.

BACKGROUND: Whether LDCT-associated stage shift translates into similar survival patterns across lung cancer histologies remains uncertain. We compared stage shift, histological differentiation, tumor characteristics, and survival between lung squamous cell carcinoma (LUSC) and adenocarcinoma (LUAD) in the National Lung Screening Trial. METHODS: Among participants diagnosed with LUSC or LUAD, stage distribution and histological differentiation were compared between LDCT and chest X-ray (CXR) arms. Survival among diagnosed cases was measured from randomization. Multivariable models tested screening arm-by-histology interactions. Screen-detected LDCT tumors were compared by histology. RESULTS: During 6.5 years of median follow-up, 498 LUAD and 249 LUSC cases were diagnosed in the LDCT arm, and 374 and 212, respectively, were diagnosed in the CXR arm. LDCT was associated with higher odds of stage I disease for LUAD (adjusted odds ratio [aOR], 2.48; 95% CI 1.88-3.28) and LUSC (aOR, 1.71; 95% CI 1.17-2.48), without significant interaction (P&#x202f;=&#x202f;0.116). LDCT was associated with lower hazard of lung cancer-specific death among diagnosed LUAD cases (adjusted hazard ratio [aHR], 0.54; 95% CI 0.43-0.66), but not among diagnosed LUSC cases (aHR, 1.04; 95% CI 0.78-1.39; P for interaction<0.001). LUSC had lower screening sensitivity, more frequent detection in annual screening rounds, greater prediagnostic tumor size increase, and fewer well-differentiated stage I tumors than LUAD. CONCLUSION: LDCT was associated with stage shift for both subtypes, but favorable survival patterns among diagnosed cases were mainly observed for LUAD. Lower screening sensitivity, greater prediagnostic tumor size increase, and poorer histological differentiation may help explain why stage shift did not translate into similar survival patterns for LUSC. TRIAL REGISTRATION: ClinicalTrials.gov, NCT00047385.

Humans

CT-Derived pelvic morphometry for preoperative risk assessment of recurrent unilateral inguinal hernia.

BACKGROUND: Recurrent inguinal hernia remains a significant challenge in abdominal wall surgery despite advances in mesh-based repair techniques and minimally invasive approaches. Although pelvic skeletal morphology has been implicated in inguinal hernia development, its association with recurrent disease remains incompletely understood. This study aimed to evaluate computed tomography (CT)-derived pelvic morphometric parameters and investigate their potential value in preoperative recurrence risk assessment. METHODS: This retrospective study included 251 male patients with preoperative abdominal CT examinations and complete clinical records who underwent elective inguinal hernia repair at a tertiary referral center. After applying the predefined eligibility criteria, 188 patients with unilateral inguinal hernias constituted the primary study cohort, including 162 primary and 26 recurrent unilateral hernias. The Radoievitch angle and Ami's line were measured independently by two blinded radiology residents using a standardized CT-based pelvic morphometric measurement protocol, and the mean values were used for analysis. Multivariable logistic regression and receiver operating characteristic (ROC) curve analyses were performed to evaluate the association between pelvic morphometric parameters and recurrent inguinal hernia. RESULTS: Patients with recurrent unilateral inguinal hernias demonstrated significantly greater affected-side Ami's line measurements (8.27&#x2009;&#xb1;&#x2009;0.63 vs. 7.90&#x2009;&#xb1;&#x2009;0.71&#xa0;cm, p&#x2009;=&#x2009;0.014) and larger Radoievitch angles (40.68&#x2009;&#xb1;&#x2009;4.02&#xb0; vs. 38.80&#x2009;&#xb1;&#x2009;3.68&#xb0;, p&#x2009;=&#x2009;0.018) than patients with primary unilateral hernias. Both the Radoievitch angle (OR 1.14, 95% CI 1.01-1.28, p&#x2009;=&#x2009;0.033) and Ami's line (OR 2.26, 95% CI 1.14-4.49, p&#x2009;=&#x2009;0.020) remained independently associated with recurrent inguinal hernia after adjustment for age and body mass index. ROC analysis demonstrated modest discriminatory performance (AUC 0.634 for the Radoievitch angle and 0.633 for Ami's line), while the multivariable model incorporating age, body mass index, and Ami's line showed slightly improved discrimination (AUC 0.655). CONCLUSION: CT-derived pelvic morphometric parameters were independently associated with recurrent unilateral inguinal hernia. Although their individual discriminatory performance was modest, standardized CT-based pelvimetry may serve as an objective adjunctive tool for individualized preoperative recurrence risk assessment in patients who already undergo CT imaging for unrelated clinical indications. Prospective multicenter studies are warranted to validate these findings and determine their clinical applicability.

Humans

The role of artificial intelligence in the diagnosis and prognosis of traumatic brain injury based on brain CT scans: a systematic review.

Traumatic brain injury (TBI) is a leading cause of emergency department visits and a major contributor to injury-related mortality and long-term neurological disability. Non-contrast computed tomography (CT) is the gold-standard imaging modality for the rapid diagnosis of TBI. Clinical outcomes depend strongly on early detection and prompt acute management. Artificial intelligence (AI)-based models may support faster automated identification of traumatic findings and early prediction of patient prognosis.&#xa0;A systematic literature search was conducted in PubMed/MEDLINE, Scopus, IEEE Xplore, ACM Digital Library, and the Cochrane Library in accordance with PRISMA 2020 guidelines to evaluate AI-based models for automated detection of TBI-related findings on CT and for prediction of clinical outcomes. Risk of bias and applicability were assessed using QUADAS-2 for diagnostic accuracy studies and PROBAST&#x2009;+&#x2009;AI for prediction model studies.&#xa0;Twenty-two studies were included. Sixteen studies evaluated diagnostic tasks and 10 evaluated prognostic outcomes, with four studies contributing to both categories. Diagnostic performance was generally high, with many studies reporting AUC values approaching or exceeding 0.90, particularly for larger lesion volumes.Prognostic performance was more variable, with moderate to high discrimination and substantial heterogeneity. Only 9 studies incorporated independent external validation, and performance was frequently lower in external cohorts. All prognostic model studies were judged to be at high overall risk of bias using PROBAST&#x2009;+&#x2009;AI, and most diagnostic accuracy studies also demonstrated high or unclear risk of bias in at least one QUADAS-2 domain, most frequently in patient selection.&#xa0;AI-based models applied to brain CT demonstrate strong technical performance for both diagnostic and prognostic tasks in TBI. However, most studies relied on retrospective designs and lacked independent external validation which limits models generalizability and raises concern for potential overfitting. Prospective, multicenter studies with standardized methodologies and rigorous external validation are required before widespread clinical implementation.

Humans

PCa Detection in PI-RADS 4 and 5 Lesions: Comparison of [68Ga]Ga-PSMA-11 PET/CT-Guided Robot-Assisted Biopsy Versus mpMRI Cognitive-Fusion TRUS-Guided Prostate Biopsy.

Lesions with a Prostate Imaging-Reporting and Data System (PI-RADS) score of 4 or greater on multiparametric MRI (mpMRI) indicate a high likelihood of prostate cancer (PCa), and guidelines recommend a targeted biopsy. We aimed to compare the diagnostic performance of robotic arm-assisted [68Ga]Ga-PSMA-11 PET/CT-guided prostate biopsy (PGPB) with mpMRI-directed cognitive-fusion transrectal ultrasound-guided biopsy (MCFB) in biopsy-na&#xef;ve men with clinical findings suggestive of PCa. Methods: This prospective, single-center, randomized clinical trial (NCT05137561) enrolled biopsy-na&#xef;ve men age 50-90 y with elevated levels of prostate-specific antigen (&#x2265;4 ng/mL) and abnormal digital rectal examination findings. All participants underwent mpMRI, and those with a PI-RADS score of 4 or greater were randomized into 2 arms. In arm 1, participants underwent PGPB for a [68Ga]Ga-PSMA-avid lesion, and participants in arm 2 underwent MCFB. Participants in arm 1 with PET-negative findings subsequently underwent MCFB, and participants with negative biopsy results underwent PET and PGPB. The primary outcome was the detection of PCa. Secondary outcomes included complication rates and participant-reported pain. Result: Of the 267 participants enrolled, 81.3% (217) had lesions with a PI-RADS score of 4 or greater and were randomized to either PGPB (n = 112) or MCFB (n = 105). PCa was detected in 97.1% of participants (101/104) in arm 1 and 81.0% (85/105) in arm 2 (P < 0.05). PGPB showed higher diagnostic accuracy for PI-RADS 5 lesions (100% vs. 95.1%, P = 0.09). Major complications were observed in arm 2 only (n = 5). Arm 1 had significantly fewer complications (10.8% vs. 51.4%, P < 0.01), a lower median visual analog scale score for pain (3 vs. 5), and shorter procedure times. The core positivity rate was higher in arm 1 (60% &#xb1; 20%), despite obtaining fewer cores. Conclusion: [68Ga]Ga-PSMA-11 PGPB demonstrated higher diagnostic performance, fewer complications, and better tolerability compared with MCFB. This approach enables integrated diagnosis and staging, offering a promising alternative for efficient, safe, and accurate evaluation of prostate cancer.

Humans