Closed-loop insulin delivery for glycaemic control in hospitalised and perioperative adults: A systematic review and meta-analysis of randomised controlled trials.

We evaluated whether closed-loop insulin delivery improves glycaemic control in hospitalised and perioperative adults. PubMed/MEDLINE, Embase, CENTRAL, and ClinicalTrials.gov were searched from inception to 29 June 2026 for randomised controlled trials comparing closed-loop or automated insulin delivery with usual care or conventional insulin therapy. Random-effects meta-analyses were conducted; risk of bias was assessed using RoB 2 and certainty of evidence using GRADE. Seven trials involving 375 analysed participants were included. Closed-loop insulin delivery increased time in target glucose range by 23.91 percentage points (95% CI 19.40 to 28.43; I2 = 0%) and reduced mean glucose by 1.79 mmol/L (95% CI 1.06 to 2.53 lower; I2 = 36.3%); certainty was moderate for both outcomes. Two trials involving 69 participants reported compatible participant-level data for clinically significant hyperglycaemia, and both estimates favoured closed-loop insulin delivery, although the evidence was exploratory and imprecise. No severe hypoglycaemic events occurred in either group, precluding reliable estimation of comparative safety. Closed-loop insulin delivery may improve glycaemic process measures, but larger pragmatic trials are needed to establish clinical benefits, safety, and implementation feasibility.

Humans

Early Worsening of Diabetic Retinopathy Following Initiation of Hybrid Closed-Loop/Automated Insulin Delivery Systems in Type 1 Diabetes: A Systematic Review and Structured Study-Level Synthesis.

BACKGROUND: Hybrid closed-loop (HCL) systems achieve rapid, algorithm-driven improvements in glycaemia in type 1 diabetes (T1D). Paradoxically, rapid improvement in glycaemic control is associated with early worsening of diabetic retinopathy (EWDR), a phenomenon established in the intensive insulin therapy era. Whether HCL initiation carries a clinically meaningful EWDR risk is unknown. No systematic review has previously addressed this question. METHODS: A systematic review and structured quantitative synthesis was performed using study-level estimates only (PROSPERO CRD:420261391951). MEDLINE, SCOPUS and Web of Science were searched to 14th May 2026. Studies reporting retinal outcomes in people with T1D initiating any HCL system were eligible. Two reviewers independently screened studies and extracted data. Risk of bias was assessed using ROBINS-I and certainty of evidence using the GRADE framework. EWDR incidence was summarised using study-level proportions, and comparative studies were summarised using study-specific risk ratios for HCL versus control therapy. Given substantial heterogeneity in EWDR definitions, retinal assessment timing, follow-up duration, and comparator groups, no pooled or meta-analytic estimates were derived. RESULTS: Eight studies (n = 1487 participants; 860 HCL users) were included; all were observational and six were retrospective. EWDR varied markedly with the timing of retinal assessment. In studies assessing the retina within ≤ 12 months of HCL initiation, EWDR rates ranged from 8.9% to 26.5%. Studies with longer follow-up reported lower rates of retinal worsening or incident DR, 6.7% at 24 months and 6.1% over a mean follow-up of 4.9 years, suggesting that these studies may capture background DR progression rather than true early worsening. Three comparative studies included 177 HCL users and 315 controls; EWDR study-specific risk ratios were directionally inconsistent, ranging from 0.32 to 1.51, and were therefore not pooled. The most consistently identified risk factors were higher baseline HbA1c and older age. The magnitude of HbA1c reduction was not a consistent predictor of EWDR in the HCL context, in contrast to pre-HCL era evidence. Risk of bias ranged from moderate to critical and certainty of evidence was very low for all outcomes. CONCLUSIONS: Study-defined retinal worsening was reported in a minority of participants. The current evidence base is dominated by retrospective studies, variable retinal assessment timing, and inconsistent EWDR definitions. Well-designed prospective studies with protocol-specified retinal surveillance anchored to HCL initiation are required to generate reliable incidence estimates, identify risk factors, determine visual consequences, and inform standardised screening guidance.

Humans

Beyond Glycaemia: Fear of Hypoglycaemia, Cognition and Functional Mobility After Advanced Hybrid Closed-Loop Therapy in Older Adults With Type 1 Diabetes: A Prespecified Secondary Analysis of a Randomised, Single-Centre Study.

BACKGROUND: Evidence on psychological, cognitive and functional outcomes of advanced diabetes technologies in older adults with long-standing type 1 diabetes (T1D) remains limited. We evaluated whether initiation of advanced hybrid closed-loop (AHCL) therapy was associated with changes in fear of hypoglycaemia, diabetes distress, psychological well-being, cognition, frailty-related measures and mobility-related function in adults aged ≥ 65 years with T1D. METHODS: This prespecified, exploratory secondary analysis was conducted within a single-centre, open-label, randomised, controlled, parallel-group trial including adults aged ≥ 65 years with long-standing T1D. Participants were randomly assigned (1:1) to initiate AHCL therapy using the MiniMed 780G system or to continue standard diabetes treatment. The secondary outcomes included WHO-5, the 17-item Diabetes Distress Scale (DDS), Hypoglycemia Fear Survey-II (HFS-II), Montreal Cognitive Assessment, Digit Symbol Substitution Test, Fried frailty phenotype and performance-based functional measures. No formal sample-size calculation was performed for these secondary outcomes. RESULTS: Thirty-one participants were randomised and 29 completed 12 months of follow-up and were included in the treatment-effect analyses. In the baseline-adjusted primary analysis, AHCL therapy was associated with a lower HFS-II score than standard treatment (adjusted mean difference -18.9; 95% CI: -32.4 to -5.4; nominal p = 0.008), although this finding did not remain statistically significant after Holm correction (adjusted p = 0.104) or in an exploratory model additionally adjusted for sex (difference -13.6; 95% CI: -32.2 to 5.0; p = 0.145). Diabetes distress, psychological well-being, global cognition and processing speed did not differ between groups. In sex-adjusted sensitivity analyses, the between-group differences remained statistically significant for 6-min walk distance (92.6 m; 95% CI: 36.8 to 148.3; p = 0.002) and Timed Up and Go performance (-2.27 s; 95% CI: -4.28 to -0.27; p = 0.028), but not for gait speed (0.27 m/s; 95% CI: -0.05 to 0.59; p = 0.099). At 12 months, 12 of 14 AHCL participants were robust and 2 were pre-frail; in the control group, 11 of 15 were robust and 4 were pre-frail. No participant was classified as frail at follow-up. CONCLUSIONS: In this small, selected cohort, AHCL therapy was associated with a nominally lower fear-of-hypoglycaemia score and better performance on selected mobility-related tests over 12 months. The fear-of-hypoglycaemia finding did not remain statistically significant after correction for multiple comparisons or additional adjustment for sex. Six-minute walk distance and Timed Up and Go remained statistically significant in the exploratory sex-adjusted sensitivity analyses, whereas the gait-speed difference did not. No measurable between-group deterioration in global cognition or processing speed was observed. These exploratory findings require confirmation in larger studies with balanced representation by sex and direct measurement of physical activity. These findings also support a person-centred clinical message: older age alone should not be regarded as a barrier to AHCL when treatment is introduced with individualised education and appropriate ongoing support.

Humans

Continuous Intraperitoneal Insulin Infusion for People With Type 1 Diabetes: A Literature Review and International Position Statement.

Achieving glucose targets without hypoglycaemia is the treatment goal in type 1 diabetes. Structured education, intensified insulin injection regimens, continuous glucose monitoring, automated insulin delivery, and ongoing support from a multidisciplinary team all support people with type 1 diabetes to achieve this goal. Despite these advances, significant barriers to achieving optimal management remain. Continuous intraperitoneal insulin infusion has comparable or better glucose outcomes to continuous subcutaneous insulin infusion and may reduce the frequency of hypoglycaemia, including severe episodes. Intraperitoneal insulin may be considered as a treatment modality for children and adults with type 1 diabetes using optimised intensive insulin therapy for whom subcutaneous insulin has failed due to lipoatrophy, -dystrophy or -hypertrophy, local allergy, subcutaneous insulin resistance or co-existing skin conditions. Failure of subcutaneous insulin may result in recurrent or unexplained severe hypoglycaemia or hyperglycaemia. Intraperitoneal insulin may also be considered as a treatment modality for people with type 1 diabetes with severe needle-phobia, and for those being considered for islet cell or pancreatic transplantation, or where transplantation is not available. This paper summarises current intraperitoneal insulin delivery technology, its potential risks and benefits, and an expert position statement. It is intended for use by diabetes specialist healthcare professionals, and as a reference for other healthcare professionals, commissioners, payors, people with diabetes, their carers, and advocates.

Humans

Factors influencing the enhancement of the new iron triangle in healthcare organisations.

PURPOSE: A new paradigm, "healthcare's new iron triangle," has been developed to emphasise the technological perspective of healthcare delivery, focusing on automation, value and empathy. The study aims to build a conceptual model and to identify factors for the enhancement of the new iron triangle in healthcare organisations. DESIGN/METHODOLOGY/APPROACH: The healthcare organisation is the primary focus point of the current study. To determine the factors, a survey of the literature and healthcare experts' opinions was conducted. The healthcare professionals validated the identified factors. Data for this study were gathered using a closed-ended questionnaire and scheduled interviews. The study employed "Total Interpretive Structural Modeling methodology and Matriced' Impacts Croise´s Multiplication Appliqué´ a UN Classement/Cross-Impact Matrix Multiplication Applied to a Classification (MICMAC) analysis" to address the "why" and "how" the factors interact and prioritise the identified factors. FINDINGS: The study found that organisational structure (F8), artificial intelligence (F1), innovation (F2) and human resources (F5) are the driving or key factors of the study. RESEARCH LIMITATIONS/IMPLICATIONS: The study primarily focused on identifying factors for the enhancement of a new iron triangle in healthcare organisations. The scope could eventually be expanded to explore more areas. PRACTICAL IMPLICATIONS: Academics and other stakeholders will have a better understanding of the key drivers for the enhancement of the new iron triangle in healthcare organisations. ORIGINALITY/VALUE: In this study, total interpretive structural modeling and cross-impact MICMAC analysis are proposed as an innovative approach to address the new iron triangle in healthcare organisations.

Humans

Food-derived extracellular vesicles as delivery platforms for medicine-food homology components in metabolic syndrome.

Diet-induced obesity and associated metabolic syndromes have become major global public health challenge, highlighting the urgent need for safe and effective strategies. Recently, food-derived extracellular vesicles (FDEVs) have garnered increasing attention as natural nanocarriers due to their excellent biocompatibility and specific targeted delivery capabilities. FDEVs can efficiently deliver medicine-food homology components (MFHCs) to precisely regulate lipid metabolism, inflammatory responses, and insulin sensitivity, thereby improving obesity and its metabolic abnormalities. This systematic review summarizes recent advances in the use of FDEVs as delivery vehicles for MFHCs to suppress diet-induced obesity and metabolic syndrome, with a particular focus on the underlying molecular mechanisms, including signaling pathway regulation and cellular metabolic remodeling. In addition, the clinical translational potential and industrial application prospects of FDEVs are evaluated, and key challenges related to preparation techniques, safety assessment, and large-scale production are discussed. By integrating current evidence, this review aims to provide theoretical framework and future perspectives for the development of FDEVs as a novel targeted delivery platform and treatment of metabolic diseases.

Extracellular Vesicles

Metabolomic Responses to Oral Glucose Tolerance Test and Hyperinsulinemic-euglycemic Clamp in CKD.

BACKGROUND: The oral glucose tolerance test (OGTT) captures integrated physiological responses involving intestinal glucose absorption, incretin signaling, and endogenous insulin secretion, whereas the hyperinsulinemic-euglycemic clamp (clamp) isolates insulin-mediated glucose uptake. Comparing plasma metabolomic responses to these two challenges may identify processes specific to intestinal nutrient delivery and how they vary in CKD. METHODS: Targeted plasma metabolomics was performed in 59 adults without diabetes (39 with CKD [eGFR <60 mL/min/1.73 m2] and 20 controls) from the Study of Glucose and Insulin in Renal Disease (SUGAR). Each participant underwent a 75-g OGTT and clamp approximately one week apart. Eighty-eight plasma metabolites were quantified at fasting and during each challenge. Metabolite levels were log-transformed and normalized using Systematic Error Removal Using Random Forest (SERRF). Metabolites were classified using adjusted regression slopes relating OGTT and clamp responses. RESULTS: The mean (SD) age and eGFR were 64 (13) years and 54 (26) mL/min/1.73 m2, respectively, and 41% were female. In the overall cohort, OGTT and clamp induced broad plasma metabolic changes, with 63 (72%) and 76 (86%) metabolites significantly altered from fasting, respectively. Seventy-three metabolites (83%) demonstrated a significant relationship between OGTT and clamp responses. Of these, 22 (25%) exhibited true concordance and 51 (58%) demonstrated similar directional changes but differed in magnitude. A total of 15 (17%) metabolites were discordant or non-corresponding, of which only three were discordant. The non-corresponding metabolites were enriched in amino acid metabolism. Eleven metabolites (13%) demonstrated differential responses between OGTT and clamp by CKD status, involving amino acid and glucose metabolism pathways. CONCLUSIONS: Metabolomic responses to OGTT and clamp were largely directionally concordant but differed in magnitude, with attenuation during OGTT. Discordant metabolites were rare, while non-corresponding metabolites were confined to amino acid pathways. CKD modified OGTT-clamp correspondence for metabolites involved in amino acid and glycolytic metabolism.

Journal Article

Alarms and alarm management with automated versus conventional ventilation in neurocritical care patients.

INTRODUCTION: False or clinically irrelevant alarms are a major driver of ICU alarm fatigue and nursing workload. Ventilator alarms make up a large share, and although automated ventilation modes can reduce manual adjustments, their effect on alarm burden is still unclear. This issue can be particularly relevant in neurocritical care patients, where precise ventilator and alarm management is imperative for patient safety. OBJECTIVES: This explorative post hoc analysis of a randomized clinical trial compared alarm frequency and management between automated ventilation and conventional ventilation in neurocritical care patients. METHODS: Ventilator alarms and manual ventilator changes were captured continuously from the ventilator for up to 24&#xa0;h per patient. The primary endpoint was a composite of workload-relevant alarms; with alarm management interventions at the ventilator as a key secondary outcome. Additional endpoints included redundant alarms, alarm duration and ventilator management. RESULTS: 13 patients received automated ventilation and 24 received conventional ventilation. No difference was observed in workload-relevant alarm frequency between automated and conventional ventilation (3.28 [2.87 to 4.30] vs 3.73 [1.66 to 7.33] alarms per hour; P&#xa0;=&#xa0;0.81), while alarm management interventions at the ventilator were lower with automated ventilation (0.14 [0.10 to 0.15] vs 0.21 [0.17 to 0.31] interventions per hour; P&#xa0;=&#xa0;0.01). Other alarm frequencies, duration of alarms and ventilator management were similar. CONCLUSIONS: In this exploratory post hoc analysis of a randomized clinical trial in neurocritical care patients during the early phase of mechanical ventilation, automated ventilation did not reduce the frequency of total or workload-relevant alarms, nor their duration, but was associated with fewer alarm management interventions compared to conventional ventilation. IMPLICATIONS FOR CLINICAL PRACTICE: Automated ventilation may not reduce alarm frequency in neurocritical care patients, but the observed reduction in alarm-related bedside interventions suggests a potential benefit for nursing workload.

Humans

Effects of automated massage chair therapy on mental health and physical health: A comprehensive study.

BACKGROUND AND OBJECTIVE: Automated massage chair therapy is a non-pharmacological intervention widely believed to enhance wellness, yet evidence regarding its effects remains limited. This 3-part study evaluated the effects of automated massage chair therapy on mental and physical health. METHODS: In Part 1, 20 moderately stressed students were randomized to receive a 20-minute automated massage chair therapy session followed by a 20-minute control session, or vice versa, with a 48-hour washout period. Blood pressure (BP), heart rate (HR), electroencephalogram (EEG), State-Trait Anxiety Inventory (STAI), and Visual Analog Scale (VAS) were measured. In Part 2, 20 hypertensive hospital staff received three 20-minute automated massage chair therapy sessions on alternate days. BP, HR, and skin blood flow (SBF) were measured. In Part 3, 20 hospital staff with chronic low back pain received three 20-minute automated massage chair therapy sessions on alternate days. Electromyogram (EMG) and VAS were measured. RESULTS: Automated massage chair therapy significantly reduced diastolic blood pressure (DBP), HR, stress, and anxiety among moderately stressed students. In hospital staff with hypertension, SBF did not change significantly, whereas BP and HR decreased significantly after automated massage chair therapy. In hospital staff with chronic low back pain, low back function improved, and pain was significantly reduced after automated massage chair therapy. CONCLUSION: These findings indicate that automated massage chair therapy may help reduce stress, lower blood pressure, and alleviate low back pain.

Humans

Evaluation of the difference between automated and measured QTc intervals in children.

BACKGROUND: The corrected QT interval (QTc) is obtained through automated ECG computations or manual physician measurements. We hypothesized that differences exist in children between the measured and automated QTc intervals within and between Healthy and hypertrophic cardiomyopathy (HCM) subjects with greater differences for HCM due to structural abnormalities. METHODS: QT measurements - Bazett correction- automated (aQTc) and measured (mQTc), were extracted from the GE MUSE database for 385 Healthy pediatric (single ECG) and 208 HCM subjects (2 ECGs), stratified by age&#xa0;<&#xa0;12 and&#xa0;&#x2265;&#xa0;12&#xa0;yrs., sex, race, and ethnicity. QTc means (SD), automated and measured differences, and the difference of the differences of aQTc and mQTc were analyzed overall and by subgroups. All ECGs were read by one pediatric cardiologist with a second cardiologist reading a random subset of HCM ECGs to evaluate intraclass correlations and agreement. RESULTS: The mQTc intervals were shorter than aQTc intervals within Healthy (p&#xa0;<&#xa0;0.001) and within first HCM ECGs (p&#xa0;<&#xa0;0.001) with both aQTc and mQTc shorter in Healthy than HCM (p&#xa0;<&#xa0;0.001). The difference in these differences was significant overall using HCM ECG 1 but not HCM ECG 2. Healthy subject aQTc and mQTc intervals differed by age, sex, and race (p&#xa0;<&#xa0;0.002). HCM ECG 1 aQTc- mQTc intervals differed for age&#xa0;<&#xa0;12&#xa0;yrs., as well as by sex and race. HCM ECG 2 intervals differed only for age&#xa0;<&#xa0;12&#xa0;yrs. CONCLUSIONS: Compared to measured values, automated QTc values were significantly longer in both Healthy and HCM subjects. Automated measurements may overestimate the QTc.

Humans

An automated geometric modeling framework in GATE for the design and optimization of high-sensitivity converging-beam SPECT collimators.

Objective.The trade-off between detection sensitivity and spatial resolution is a fundamental challenge in designing organ-dedicated Single-photon emission computed tomography (SPECT) collimators. While converging-hole geometries offer a solution, their optimization is often hindered by the lack of flexible computational tools capable of modeling large-scale, non-parallel hole arrays. This study aims to develop an automated geometric modeling framework to facilitate the design and evaluation of complex converging- and diverging-hole collimators within standard Monte Carlo environments.Approach.We developed a specialized modeling framework by implementing custom C++ classes and a vector-based alignment algorithm within GATE. This platform enables automated, orientation-consistent construction of large-scale converging arrays not natively supported by standard implementations. A high-sensitivity pure cone-beam collimator (CBC) was designed using this framework. The evaluation used hot-rod, disc, and Jaszczak phantoms for physical characterization, while XCAT and dedicated brain models were employed for clinical tasks, including cardiac, brain perfusion, and DaTscan SPECT simulations.Main results.The CBC achieved a nearly fourfold sensitivity increase compared to a conventional low-energy high-resolution parallel-hole collimator at a 20 cm radius of rotation, while maintaining comparable spatial resolution. Despite a 52.3% field of view reduction, the CBC yielded a 2.2-fold noise reduction (CV: 11.7% vs 25.9%) and mitigated partial volume effects via geometric magnification. XCAT and brain phantom simulations confirmed enhanced anatomical definition and contrast recovery in cardiac, perfusion, and DaTscan tasks.Significance.This work provides an efficient computational tool for rapid design space exploration of advanced collimator geometries. The results demonstrate that the proposed CBC design offers a significant sensitivity advantage, making it highly suitable for high-performance, small-volume clinical applications such as brain and cardiac molecular imaging.

Tomography, Emission-Computed, Single-Photon

Automated CEAP Classification of Venous Duplex Reports Using Multimodal Artificial Intelligence.

OBJECTIVE: To develop and internally validate a prototype multimodal artificial intelligence system for automated CEAP (Clinical, Etiological, Anatomical and Pathophysiological) classification of venous duplex ultrasound (VDUS) reports, integrating natural language processing of free-text components with computer vision analysis of hand-drawn anatomical diagrams. METHODS: Single centre retrospective observational study using routinely collected clinical data. One thousand consecutive venous duplex ultrasound reports from Cambridge University Hospitals NHS Foundation Trust, UK (July 2024 - May 2025) were labelled according to the CEAP classification, excluding the Etiological component, which could not be reliably determined from duplex reports alone. Transfer learning was applied using ClinicalBERT for text and MobileNetV3 for diagrammatic data. Clinical classes were predicted from request line text. Text- and image-based pathophysiological models were developed for four anatomical territories (Great Saphenous Vein, Small Saphenous Vein, Deep system, Perforators), combined using late fusion with probability averaging. RESULTS: The clinical CEAP model achieved accuracy of 0.91, macro-F1 of 0.82, and macro-AUC of 0.98. Pathophysiological prediction varied, with text models broadly outperforming image models. Fusion yielded heterogeneous benefits, improving SSV performance but reducing Deep system accuracy. The performance of the final pathophysiological CEAP fusion models varied across anatomical territories: accuracy ranged from 0.70-0.92 and macro-AUC from 0.80-0.92. CONCLUSION: This study demonstrates the feasibility of automated CEAP classification from VDUS reports. Despite class imbalance affecting minority class predictions, the strong discriminatory performance validates this multimodal ML model for extracting clinically meaningful information from real-world data. This approach offers potential, pending external validation, to streamline vascular services through automated triage and guideline-compliant decision making.

Artificial intelligence

Intervention Without Borders - an Automated Self-Guided AI-Enhanced Psychoeducation Intervention for Dementia Caregivers: Parallel-Group Randomized Waitlist-Controlled Trial.

OBJECTIVE: To examine whether a fully automated, self-guided intervention (PDC30) could improve caregiver well-being over a 1-month waitlist control in an international sample. DESIGN: Randomized waitlist-controlled trial. SETTING: Web-based platform accessible globally. PARTICIPANTS: 441 individuals responded to study promotion on the internet, of whom 274 from 43 countries met the study criteria and were randomized. Eligible participants were adults providing &#x2265;10 care hours weekly to community-dwelling relatives with dementia, scoring &#x2265;5 on Patient Health Questionnaire-9 (PHQ-9), and without recent caregiver intervention. INTERVENTION: Available 24/7, PDC30 is a self-guided, automated intervention consisting of a Guidebook, an AI-powered counseling chatbot, and interactive applications for cognitive-behavioral techniques, relaxation, and caregiver-recipient bonding. MEASUREMENTS: At baseline and follow-ups at 1, 2, and 3 months, depression was assessed by PHQ-9. Secondary outcomes were measured with validated brief versions of anxiety, burden, and positive gains. RESULTS: Intent-to-treat analysis using mixed-effects regression showed treatment x time2 effects on all outcomes except anxiety. At 1-month follow-up, coinciding with exclusive access to PDC30, intervention caregivers showed significant improvements in depression (d = -0.37), burden (d = -0.34), and positive gains (d = 0.42). The differences mostly disappeared after control participants received the intervention, while improvements in both groups were sustained thereafter. Participants reported using the website several times weekly, were generally satisfied with it, and found the chatbot most helpful. CONCLUSIONS: The effects on depression and other outcomes were consistent with those observed for in-person programs, suggesting the viability of well-designed automated intervention. The study demonstrates the feasibility, acceptability, and potential global health impact of PDC30.

Humans

Performance of Automated Hematology Analyzer Criteria in Detecting Peripheral Blood Smear Abnormalities: A Systematic Literature Review.

OBJECTIVES: Criteria for visual examination of stained peripheral blood smear (PBS) differ among institutions in the United States and internationally. In an effort to standardize review criteria, the International Consensus Group for Hematology Review (ICGHR) proposed in 2005 a consensus list of rules for CBC findings that should trigger a review of automated cell counter results and potentially lead to further testing or blood smear review. The primary aim of this paper is to report on the published literature in the past 20&#x2009;years regarding PBS review criteria and their ability to identify relevant peripheral blood abnormalities. METHODS: We performed a systematic review of the published literature from 2005 to 2025 to investigate and summarize PBS review criteria and performance in the context of automated hematology analyzers in clinical laboratories. RESULTS: Of 5351 citations, 68 studies met our search criteria. These studies included 22 countries and all major hematology analyzer manufacturers. Marked variability was observed in study populations, analyzer flagging criteria, details of PBS visual review, definitions of a "positive" smear, and approaches to statistical data analysis. Across studies, the blast flag sensitivity ranged from 18% to 100% while the blast flag specificity ranged from 17% to 100%. Wide ranges in sensitivity/specificity were also seen for atypical and/or abnormal lymphocyte flags across studies. For studies analyzing the same patient population, less striking variation was seen across instruments. CONCLUSIONS: This systematic review provides a 20-year overview of the literature, highlighting significant variability in PBS review criteria, dependence on study design and hematology analyzer, and the importance of developing harmonized evidence-based guidelines.

Humans

Efficacy and Safety of Once-Weekly Semaglutide 2.0&#x2009;mg as an Add-On to Dose-Reduced Insulin Glargine versus Dose-Titrated Insulin Glargine in People With Type 2 Diabetes and Overweight (SUSTAIN OPTIMIZE).

AIMS: Type 2 diabetes (T2D) management with basal insulin can lead to hypoglycaemia and weight gain. SUSTAIN OPTIMIZE compared once-weekly semaglutide 2.0&#x2009;mg as add-on to dose-reduced insulin glargine (Sema+IGlarreduced) versus dose-titrated IGlar (IGlartitrated) on glycated haemoglobin (HbA1c), body weight (BW), daily insulin dose, and participant satisfaction. MATERIALS AND METHODS: SUSTAIN OPTIMIZE was a 40-week, phase 3b, open-label, randomised study. Adults with T2D, overweight (body mass index &#x2265;&#x2009;25&#x2009;kg/m2), and treatment with basal insulin &#x2264;&#x2009;40&#x2009;units/day were randomised 1:1 into Sema+IGlarreduced or IGlartitrated. The primary endpoint was change in HbA1c using a non-inferiority approach. Secondary endpoints assessed superiority of Sema+IGlarreduced versus IGlartitrated in reducing HbA1c, BW, daily insulin dose, and improving Diabetes Treatment Satisfaction Questionnaire change version (DTSQc) scores. RESULTS: Overall, 573 participants were randomised. Sema+IGlarreduced achieved both non-inferiority and superiority versus IGlartitrated in HbA1c reduction (estimated treatment difference [ETD]: -0.74%; 95% confidence interval [CI95]: -0.90, -0.59) and superiority in BW change (ETD: -8.5&#x2009;kg; CI95: -9.5, -7.4), relative daily insulin dose change (ETD: -121.9%; CI95: -143.1, -100.6), and DTSQc scores (ETD: 2.6; CI95: 1.6, 3.5) (p&#x2009;<&#x2009;0.0001 for all endpoints). No new safety concerns were identified. Severe hypoglycaemia was reduced (rate ratio: 0.45; CI95: 0.23, 0.87; p&#x2009;=&#x2009;0.02), while gastrointestinal events were higher for Sema+IGlarreduced (310 vs. 32 events). CONCLUSIONS: Once-weekly subcutaneous semaglutide 2.0&#x2009;mg as add-on to dose-reduced IGlar achieved superior reductions in HbA1c, BW, and daily insulin dose in people with T2D and overweight, while reducing their risk for severe hypoglycaemia compared to dose-titrated IGlar alone.

Adult

The interplay between circadian misalignment or sleep disturbances and cognition and brain function in individuals with different degrees of insulin resistance - a systematic review.

Disruption of sleep increases the risk of type 2 diabetes and worsens cognitive outcomes, yet few studies have evaluated the interaction between insulin resistance and sleep parameters in relation to cognitive outcomes or the risk of dementia. This systematic review examines how circadian misalignment and sleep disturbances affect cognition and neuroimaging findings in individuals with varying degrees of insulin resistance. Across 27 studies, disrupted circadian rhythmicity and sleep disturbances were negatively associated with brain health, possibly through its effects on insulin sensitivity, whereas the impact of sleep duration and quality were inconclusive. Methodological heterogeneity, reliance on cross-sectional designs, and limited control for confounders restricted definitive conclusions and highlighted the need for longitudinal and interventional studies with objective measurements. Nonetheless, the findings support circadian rhythmicity as a potentially modifiable risk factor for preserving cognition in insulin-resistant populations. Future research should prioritise prospective and interventional studies and focus on biological markers rather than self-reported outcomes.

Humans

Premeal insulin administration lowers postprandial blood glucose and increases myocardial microvascular blood flow in people with type 1 diabetes: a randomised, crossover clinical trial.

AIMS/HYPOTHESIS: We aimed to evaluate whether prandial insulin timing affects vascular function in people with type 1 diabetes. Our hypothesis was that premeal insulin administration would lead to greater myocardial microvascular blood flow (MBF) via blunting postprandial hyperglycaemia. METHODS: People with type 1 diabetes between 18 and 35 years of age with BMI <30 kg/m2 underwent two protocols with a 1:1 randomised crossover design wherein prandial insulin was injected either 15 min before or 15 min after meal intake began. To provide a physiological comparison, age-, sex- and BMI-matched control participants completed one study where they consumed the same meal but received no exogenous insulin. Glucose, insulin, vascular function (including ultrasound measures of myocardial and skeletal muscle microvascular perfusion, aortic stiffness, brachial artery endothelial function) and biomarkers of systemic inflammation and endothelial dysfunction were assessed at baseline and then 2 h after meal ingestion within each protocol. The primary outcome was change in myocardial MBF within each protocol. Study personnel assessing outcomes were masked to group assignment. RESULTS: Eighteen people with type 1 diabetes and 18 matched control participants were analysed within each protocol. Glucose area under the curve was significantly greater (p=0.015) in the postmeal insulin study compared with the premeal insulin study in participants with type 1 diabetes. Myocardial microvascular flow velocity significantly increased (p=0.031) with premeal insulin administration in people with type 1 diabetes and this consequently led to greater myocardial MBF (p=0.044). There were no changes in myocardial MBF within the other protocols. Changes in vital signs were similar between all protocols. CONCLUSIONS/INTERPRETATION: Appropriately timed premeal insulin led to lower postprandial blood glucose along with increased myocardial MBF in people with type 1 diabetes. Further work is needed to determine the underlying aetiology of these changes. TRIAL REGISTRATION: ClinicalTrials.gov NCT04730882.

Humans

Overcoming Immunological Barriers in MSC-Derived Insulin-Producing Cells through CRISPR-Based Hypoimmunogenic Engineering and Translational Perspectives for Type 1 Diabetes.

Mesenchymal stromal cell (MSC)-derived insulin-producing cells (IPCs) represent an emerging strategy for &#x3b2;-cell replacement in type 1 diabetes mellitus (T1DM) owing to their differentiation potential, intrinsic immunomodulatory properties, and lower tumorigenic risk compared with pluripotent stem cell-derived platforms. However, accumulating evidence indicates that differentiation-associated immunogenicity, context-dependent immune recognition, and recurrent autoimmune responses may substantially limit long-term graft survival and therapeutic durability following transplantation. This review critically examines the immunological barriers associated with MSC-derived IPCs, including altered MHC expression, susceptibility to alloimmune and autoimmune-mediated rejection, and potential reactivation of autoreactive immune memory. We discuss the application of CRISPR-based hypoimmunogenic engineering strategies targeting antigen presentation pathways, NK-cell activation, and immune checkpoint modulation to generate more immune-evasive MSC-derived IPCs while preserving &#x3b2;-cell functionality. By integrating insights from T1DM immunopathogenesis, MSC biology, genome editing, and translational immunology, we propose a framework linking immune engineering with controlled differentiation, functional maturation, and long-term safety evaluation. In parallel, we comparatively position MSC-derived IPCs alongside clinically advancing iPSC-derived &#x3b2;-cell platforms to highlight their distinct translational niche, including potential advantages related to safety, immunomodulatory capacity, manufacturing accessibility, and scalability, while acknowledging the superior functional maturity and clinical progression currently demonstrated by iPSC-derived systems. Finally, we discuss key translational challenges, including genomic stability, immune-evasion durability, GMP-compliant manufacturing, and the need for rigorous functional and immunological benchmarking prior to clinical application of hypoimmunogenic MSC-derived IPC therapies in T1DM.

Humans