Search PubMedSearch

PubMed · 42420766

Early Worsening of Diabetic Retinopathy Following Initiation of Hybrid Closed-Loop/Automated Insulin Delivery Systems in Type 1 Diabetes: A Systematic Review and Structured Study-Level Synthesis.

Abstract

BACKGROUND: Hybrid closed-loop (HCL) systems achieve rapid, algorithm-driven improvements in glycaemia in type 1 diabetes (T1D). Paradoxically, rapid improvement in glycaemic control is associated with early worsening of diabetic retinopathy (EWDR), a phenomenon established in the intensive insulin therapy era. Whether HCL initiation carries a clinically meaningful EWDR risk is unknown. No systematic review has previously addressed this question. METHODS: A systematic review and structured quantitative synthesis was performed using study-level estimates only (PROSPERO CRD:420261391951). MEDLINE, SCOPUS and Web of Science were searched to 14th May 2026. Studies reporting retinal outcomes in people with T1D initiating any HCL system were eligible. Two reviewers independently screened studies and extracted data. Risk of bias was assessed using ROBINS-I and certainty of evidence using the GRADE framework. EWDR incidence was summarised using study-level proportions, and comparative studies were summarised using study-specific risk ratios for HCL versus control therapy. Given substantial heterogeneity in EWDR definitions, retinal assessment timing, follow-up duration, and comparator groups, no pooled or meta-analytic estimates were derived. RESULTS: Eight studies (n = 1487 participants; 860 HCL users) were included; all were observational and six were retrospective. EWDR varied markedly with the timing of retinal assessment. In studies assessing the retina within ≤ 12 months of HCL initiation, EWDR rates ranged from 8.9% to 26.5%. Studies with longer follow-up reported lower rates of retinal worsening or incident DR, 6.7% at 24 months and 6.1% over a mean follow-up of 4.9 years, suggesting that these studies may capture background DR progression rather than true early worsening. Three comparative studies included 177 HCL users and 315 controls; EWDR study-specific risk ratios were directionally inconsistent, ranging from 0.32 to 1.51, and were therefore not pooled. The most consistently identified risk factors were higher baseline HbA1c and older age. The magnitude of HbA1c reduction was not a consistent predictor of EWDR in the HCL context, in contrast to pre-HCL era evidence. Risk of bias ranged from moderate to critical and certainty of evidence was very low for all outcomes. CONCLUSIONS: Study-defined retinal worsening was reported in a minority of participants. The current evidence base is dominated by retrospective studies, variable retinal assessment timing, and inconsistent EWDR definitions. Well-designed prospective studies with protocol-specified retinal surveillance anchored to HCL initiation are required to generate reliable incidence estimates, identify risk factors, determine visual consequences, and inform standardised screening guidance.

Explore related subjects

Keep this discovery

BibTeXRIS

Matthew Anson, Ahmed Iqbal, Shazli Azmi, Philip Weston, Lucy Hughes, Mahreen Choudhury, David M Hughes, Yalin Zheng, Philip I Burgess, Uazman Alam. 2026-07-08. Early Worsening of Diabetic Retinopathy Following Initiation of Hybrid Closed-Loop/Automated Insulin Delivery Systems in Type 1 Diabetes: A Systematic Review and Structured Study-Level Synthesis.. https://doi.org/10.1111/dom.71084

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

Diabetic macular edema and GLP-1 receptor agonist use: a systematic review and meta-analysis.

BACKGROUND: Glucagon-like peptide-1 receptor agonists (GLP-1RAs) are widely used for type II diabetes and obesity because of their cardiometabolic benefits. However, concerns regarding potential ocular adverse effects, particularly diabetic macular edema (DME), have prompted the need to clarify their retinal safety. METHODS: A systematic review and meta-analysis study was conducted in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses and Meta-analysis of Observational Studies in Epidemiology statements (PROSPERO registration: CRD420251176164). MEDLINE (Ovid), EMBASE (Ovid), CENTRAL (Ovid), Web of Science, and PubMed were searched from inception to October 24, 2025. Randomized trials and observational cohort or case-control studies, including individuals with diabetes without baseline DME and exposed to GLP-1RAs were eligible. Two reviewers independently screened studies, extracted data, and assessed risk of bias using ROBINS-I. Certainty of evidence was evaluated using Grading of Recommendations, Assessment, Development, and Evaluation. Random-effects models were used to pool incidence proportions and hazard ratios (HRs). RESULTS: Thirteen retrospective cohort studies (2021-2025) using large real-world databases were included. Across 6 studies, the pooled proportion of incident DME among GLP-1RA users was 0.14 (95% CI: 0.07-0.23; I² = 99.8%). Compared with mixed antihyperglycemic therapies, GLP-1RA use was not associated with increased DME risk (pooled HR: 0.81, 95% CI: 0.52-1.26). GLP-1RAs were associated with a higher relative risk of DME compared with sodium-glucose cotransporter-2 inhibitors (HR: 1.50, 95% CI: 1.17-1.94) but not compared with dipeptidyl peptidase-4 inhibitors (HR: 0.90, 95% CI: 0.69-1.19). Evidence certainty was very low. CONCLUSION: Current low-certainty observational evidence does not support an overall increased risk of DME with GLP-1RA use. Prospective studies are needed to clarify comparative retinal safety.

Humans

Optimal dose and exercise modality to improve HbA1c in older adults with type 2 diabetes mellitus: a systematic review with pairwise, network, and dose-response meta-analyses.

We aimed to compare exercise modalities and evaluate dose-response relationships with glycemic control including continuous aerobic exercise (CAE), resistance training (RT), combined exercise (CE), mind-body exercise (MBE), and high-intensity interval training (HIIT) in older adults with type 2 diabetes mellitus (T2DM). Three databases were searched for randomized controlled trials of exercise interventions in older adults with T2DM reporting glycated hemoglobin (HbA1c). Pairwise, Bayesian network, and dose-response meta-analyses were conducted. Compared with control, HIIT demonstrated the largest estimated reduction (MD = -0.95%; 95% CrI -1.45, -0.49), followed by CE (MD = -0.59%; 95% CrI -0.93, -0.25), CAE (MD = -0.46%; 95% CrI -0.69, -0.24), MBE (MD = -0.42%; 95% CrI -0.76, -0.10), and RT (MD = -0.29%; 95% CrI -0.51, -0.08). Dose-response network meta-analyses suggested a non-linear association between overall exercise dose and HbA1c reduction, with maximal estimated benefits at approximately 704 METs-min/week with the 95% CrI excluding zero between 241 and 920 METs-min/week. HIIT demonstrated the steepest estimated dose-response relationship, but with wider credible intervals. Other exercise modalities showed more gradual dose-response patterns across their estimated effective ranges. Our findings suggest that exercise prescription for older adults with T2DM should be individualized according to exercise modality, dose, and health status.

Humans

Mobile health apps improve Health-Related Quality of Life in Type 2 Diabetes Mellitus by enhancing medication adherence: A multicentre randomised controlled trial with mediation analysis.

AIMS: This study evaluated whether a gamified mHealth application (CareAide&#xae;) improves Health-Related Quality of Life (HRQoL) in Type 2 Diabetes Mellitus (T2DM) and whether this effect is mediated by medication adherence. METHODS: Prespecified secondary analysis of the T2DM cohort from a 6-month multicentre RCT (NCT06068309; N&#x202f;=&#x202f;663; three Malaysian hospitals). Participants were randomised 1:1 to standard care or CareAide&#xae;. Adherence (MMAS-8), EQ-5D-5L utility (Malaysian value set), and AQoL-6D were assessed at baseline and 6 months. Simple mediation analysis (PROCESS Model 4; 5000 bootstraps) adjusted for baseline HRQoL. RESULTS: CareAide&#xae; significantly predicted higher MMAS-8 scores (mean difference +1.756; d = 1.638; p&#x202f;<&#x202f;0.001). Higher MMAS-8 scores significantly predicted improved AQoL-6D utility (b = 0.024; p&#x202f;<&#x202f;0.001). The direct effect on AQoL-6D was non-significant (p&#x202f;=&#x202f;0.248). Bootstrapped indirect effect confirmed full mediation via AQoL-6D (0.042; 95% CI [0.024, 0.060]). A sensitivity analysis adjusting for baseline HbA1c confirmed full mediation (indirect = 0.034; 95% CI [0.015, 0.052]; n&#x202f;=&#x202f;563). EQ-5D-5L utility showed a significant direct between-group difference at 6 months (p&#x202f;=&#x202f;0.012) but did not operate as a mediation outcome. CONCLUSIONS: Medication adherence fully mediates the AQoL-6D HRQoL benefit of a gamified mHealth intervention in T2DM, as confirmed by both the primary and HbA1c-adjusted sensitivity analyses. These findings support integration of behaviourally informed digital adjuncts into routine primary diabetes care.

Humans