Alarms and alarm management with automated versus conventional ventilation in neurocritical care patients.
Abstract
INTRODUCTION: False or clinically irrelevant alarms are a major driver of ICU alarm fatigue and nursing workload. Ventilator alarms make up a large share, and although automated ventilation modes can reduce manual adjustments, their effect on alarm burden is still unclear. This issue can be particularly relevant in neurocritical care patients, where precise ventilator and alarm management is imperative for patient safety. OBJECTIVES: This explorative post hoc analysis of a randomized clinical trial compared alarm frequency and management between automated ventilation and conventional ventilation in neurocritical care patients. METHODS: Ventilator alarms and manual ventilator changes were captured continuously from the ventilator for up to 24 h per patient. The primary endpoint was a composite of workload-relevant alarms; with alarm management interventions at the ventilator as a key secondary outcome. Additional endpoints included redundant alarms, alarm duration and ventilator management. RESULTS: 13 patients received automated ventilation and 24 received conventional ventilation. No difference was observed in workload-relevant alarm frequency between automated and conventional ventilation (3.28 [2.87 to 4.30] vs 3.73 [1.66 to 7.33] alarms per hour; P = 0.81), while alarm management interventions at the ventilator were lower with automated ventilation (0.14 [0.10 to 0.15] vs 0.21 [0.17 to 0.31] interventions per hour; P = 0.01). Other alarm frequencies, duration of alarms and ventilator management were similar. CONCLUSIONS: In this exploratory post hoc analysis of a randomized clinical trial in neurocritical care patients during the early phase of mechanical ventilation, automated ventilation did not reduce the frequency of total or workload-relevant alarms, nor their duration, but was associated with fewer alarm management interventions compared to conventional ventilation. IMPLICATIONS FOR CLINICAL PRACTICE: Automated ventilation may not reduce alarm frequency in neurocritical care patients, but the observed reduction in alarm-related bedside interventions suggests a potential benefit for nursing workload.
Explore related subjects
Keep this discovery
Geertje J C van Limpt, Peter van Vliet, Manon A Molenaar, Ashley J R de Bie, Lisan van Haren, Tobias D van Leijsen, Chiara Robba, Jante S Sinnige, Janneke Horn, Ary Serpa Neto, Frederique Paulus, Marcus J Schultz, Laura A Buiteman-Kruizinga, ACTiVE investigators. 2026-06-18. Alarms and alarm management with automated versus conventional ventilation in neurocritical care patients.. https://doi.org/10.1016/j.iccn.2026.104471
Cite the original work for its findings. Save a collection to share your selection of sources.
Discover connections
Connections use source metadata and explicit phrase matches, not verified experimental comparisons.