Search PubMedSearch

SEARCH · Search PubMed

Results for “screw placement accuracy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

166 records · Page 9Linked to original sources

Unravelling bioanalytical innovations, degradation processes, and impurity landscapes of VEGFR inhibitors.

From pre-formulation studies to clinical trials, VEGFR-targeted small-molecule tyrosine kinase inhibitors (TKIs) require rigorous analytical standards. Bioanalysis, stability-indicating studies, and impurity profiling are used to examine chromatographic advances for VEGFR-targeted TKIs like sunitinib, pazopanib, axitinib, sorafenib, cabozantinib, vandetanib, apatinib, lenvatinib, nintedanib, and regorafenib. An LC-MS/MS and UPLC-MS/MS routinely show sub ng/mL performance, as shown by LLOQs (0.2 ng/mL) for sunitinib and axitinib, 1 ng/mL for pazopanib, 5-7 ng/mL for sorafenib, 0.5-1.5 ng/mL for regorafenib metabolic products, and 0.1-0.5 ng/mL for lenvatinib. These approaches are used for pharmacokinetics and therapeutic drug monitoring due to their good correlation coefficient of 0.1-10,000 ng/mL, accuracy of 95%-108%, and precision of 15% RSD. UPLC-QTOF-MS/MS distinguishes degradants and metabolites during forced degradation studies, enabling structural elucidation following ICH M7 risk evaluation protocol. HPTLC/MLC offers fast, sensitive screenings, while RP-HPLC/DAD or HPLC-UV offer reliable, cost-effective routine quality-control solutions with LOD/LOQ in the μg/mL range and linearity of 10-240 μg/mL. This review lists the structures and CAS numbers of ten VEGFR-2 TKI degradants and metabolites, as well as pharmacopeial impurities in SMILES forms. It will be useful for future method development and regulatory applications. To ensure VEGFR-targeted TKI quality, safety, and therapeutic efficacy, LC-MS/MS for trace quantification and HRMS for structure elucidation provide a robust, future-oriented framework. To improve VEGFR-targeted TKI quality, safety, and regulatory compliance, analytical development should focus on HRMS-based impurity characterization, AI-assisted degradation prediction, green chromatography, and harmonized bioanalytical validation.

Humans

Physical reconfiguration of limb electrodes for Precordial Bipolar Lead acquisition: Morphological validation against digital subtraction.

BACKGROUND: The V2 - V1 Precordial Bipolar Lead (PBL) selectively evaluates the right-to-left retrosternal axis and has shown diagnostic value beyond the standard 12‑lead electrocardiogram. However, its use has been limited by the need for raw electrocardiographic data and post-processing software. This study evaluated whether a simple physical reconfiguration of limb electrodes could reproduce the digitally derived V2 - V1 morphology with sufficient accuracy for clinical application. METHODS: Thirty-seven subjects underwent two sequential 10-s 12‑lead recordings using a Cardiovit FT-1 electrocardiograph sampled at 1000 Hz. In the standard recording, the digital PBL was calculated as V2 - V1. In the second recording, the right-arm and left-arm electrodes were repositioned to the V1 and V2 sites so that Lead I directly recorded the retrosternal dipole. Signals were filtered, synchronized, and analyzed using median beats. Morphological agreement was assessed with Pearson correlation on Z-normalized signals, while absolute agreement was evaluated using Lin's concordance correlation coefficient (CCC), intraclass correlation coefficient (ICC (Lewis, 1931; Nehb, 1938 [1,2])), root mean square error (RMSE), and Bland-Altman analysis. RESULTS: Mean Pearson correlation between digital and physical PBL was 0.955 (SD 0.043), with segment-specific correlations of 0.953 (SD 0.054) for QRS and 0.967 (SD 0.052) for ST-T. Lin's CCC and ICC(2,1) were both 0.871 (SD 0.110), and RMSE was 0.091 (SD 0.049) mV. Bland-Altman analysis showed minimal bias (-0.008 mV). CONCLUSIONS: Physical acquisition of the V2 - V1 PBL achieved high agreement with the digitally derived signal, supporting a simplified analog method for broader clinical implementation.

Humans

Future promise, current clinical ambiguity: a systematic review of machine learning algorithm outputs predicting risk of cardiovascular disease.

OBJECTIVE: To examine whether the outputs of machine learning algorithms designed to predict risk of cardiovascular disease (CVD) address known deficiencies of the Framingham Risk Score (FRS) and improve risk estimates. METHODS: For this critical review, Medline, Embase and IEEE were searched from inception to 1 January 2025. Included were studies describing machine learning algorithms designed to specifically compare output of cardiovascular risk assessment with the FRS. Commentaries, letters, unpublished work or non-peer-reviewed papers were excluded.Following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, two reviewers screened titles and abstracts independently, then populated a purpose-built data extraction form. A subsequent qualitative thematic analysis focused on algorithms' strengths, added value, potential harms, unintended consequences and equity implications.The main outcome assessed was whether, among healthy adults, the algorithm improved CVD risk prediction relative to the FRS. RESULTS: Of 707 studies retrieved, 29 met inclusion criteria. 23 reported improved predictive ability relative to the FRS. Most datasets and/or medical records used included sociodemographic predictors of CVD not included among FRS inputs. Some added costly diagnostic tests like CT angiography to FRS screening indicators. When they were defined, inputs and outcomes such as hypertension or myocardial infarction did not always adhere to FRS values. Statistical significance was generally taken as a proxy for clinical significance. Some algorithms overestimated the number at risk compared with the FRS without discussing whether that larger proportion might be at risk of overdiagnosis rather than CVD, while a few decreased the proportion found to be at risk. CONCLUSIONS: Use of artificial intelligence to improve accuracy of risk assessment for CVD demonstrates the technological capacity to merge known sociodemographic predictors with biologic variables and examine non-linear interactions among these. Still needed to achieve patient benefit is clinical insight, adherence to screening principles and cost-benefit assessment of inputs selected.

Humans

Meta-PseU: A meta-classifier for robust prediction of RNA pseudouridine modification sites from long sequences.

BACKGROUND AND OBJECTIVES: Pseudouridine (Ψ) represents one of the most abundant and conserved RNA modifications. Ψ provides an additional hydrogen-bond donor that enhances RNA structural stability and modulates translation. It participates in diverse biological processes, including RNA-protein interactions, splicing, translational control, and stress responses. Aberrant pseudouridylation is implicated in cancer, neurodegenerative disorders, and autoimmune diseases. Despite its biological importance, experimental identification of Ψ sites remains time-consuming and costly, limiting the feasibility of transcriptome-wide profiling. Computational approaches have therefore become essential complements to experimental techniques. However, state-of-the-art machine-learning and deep-learning predictors often suffer from limited generalizability due to small training datasets. To overcome these issues, we aim at constructing new long-sequence datasets and developing a novel Ψ site predictor. METHODS: New long-sequence datasets were constructed as benchmarks for RNA Ψ-site prediction. The Ψ modification sites in RMBase 3.0 were mapped to the reference genomes across three species of human, mouse, and yeast, and the RNA sequences with a length of 201 were generated by extending the upstream and downstream from the mapped, central sites. To eliminate sequence redundancy, the sequences were clustered using CD-HIT with a 70% sequence identity threshold. We developed Meta-PseU, a logistic regression-based meta-classifier that considered 118 machine learning and deep learning classifiers. The datasets and programs are freely accessible at https://github.com/kuratahiroyuki/MetaPseU. RESULTS: By optimizing model configuration, we proposed the Meta-PseU model stacking 32 machine learning and deep learning classifiers out of 118 classifiers. Meta-PseU substantially improved model generalizability, overcoming a key limitation of existing approaches. It greatly outperformed state-of-the-art predictors and achieved increasing accuracy with increasing sequence length. CONCLUSIONS: Long-sequence datasets were newly constructed as benchmarks for RNA Ψ-site prediction. Meta-PseU offers a new framework for robust Ψ-site identification by using long sequences.

Pseudouridine

Retrosigmoid craniotomy surgical guide: The way forward for precise exposure of the transverse-sigmoid sinuses.

INTRODUCTION: The retrosigmoid craniotomy is the workhorse approach to the cerebellopontine angle. Accurate localisation of the transverse-sigmoid junction (TSJ) is key for optimised exposure and cerebellar retraction. Various methods, both anatomical and navigational, have been used but with suboptimal results. We utilised a 3D-printed retrosigmoid surgical guide in an attempt to overcome this and report our early outcomes and experiences in the design, production and utilisation of the guide. METHODS: This is a prospective cohort study of the patients with retrosigmoid craniotomies performed using the surgical guides. Patient demographics and diagnoses, along with the accuracy of the planned burrhole and craniotomy, need for craniotomy extension, presence of venous sinus injury, set-up time, and cost were reported. RESULTS: There were ten cerebellopontine angle cases in which the surgical guides were utilised, three petrous meningiomas, two trigeminal neuralgias, two metastasis, and three other tumours. The planned burrhole and craniotomy were precise in all cases with accurate exposure of the TSJ and no requirement for craniotomy extension. The mean set up time was 3.9 min, and the mean cost of the surgical guides was USD 470.90. One elderly patient had an intraoperative transverse sinus injury related to adherent dura that was planned for exposure. CONCLUSION: The 3D-printed surgical guide is a potential solution to the rapid, precise and consistent identification of the TSJ when performing a retrosigmoid craniotomy. We present our early experience and discuss nuances in the designing, production, and intraoperative phases to optimise the precision of this guide. We suggest two methods to avoid sinus injury in elderly patients: either to plan the craniotomy to the edge of the sinus, or to plan sinus exposure but to use burr drills rather than the osteotome, as in our case, to expose the sinus.

Humans

Construction of precision clinical-proteomics risk model based on machine learning for predicting heart failure in type II diabetes mellitus.

BACKGROUND AND AIMS: Heart failure (HF) is a severe complication in type 2 diabetes mellitus (T2DM), but current risk stratification scores have limited predictive accuracy. We aimed to develop novel prediction tools integrating clinical variables with proteomics to improve risk stratification of hospitalization for HF in T2DM. METHODS AND RESULTS: In this study, we included 2111 UK Biobank participants with T2DM but no prior HF, and profiled 2920 proteins to predict 10-year incident HF hospitalization. Participants were randomly divided into training (70%), tuning (10%), and validation (20%) sets.Three prediction models were developed: a Clinical model based on demographic characteristics, comorbidities, medication use, and laboratory indices; a Protein model based on 40 proteins selected by the Light Gradient Boosting Machine (LGBM); and the Clinical OMics and Protein ASSessment for Heart Failure (COMPASS-HF) model, which integrated both clinical variables and the LGBM-selected proteins. Models were evaluated for area under the curve (AUC), sensitivity, and specificity. During follow-up, 168 participants (7.96%) developed incident HF. The COMPASS-HF model showed better discrimination than the Clinical model, with an AUC of 0.897 (95% CI: 0.850-0.945) versus 0.790 (95% CI: 0.723-0.856). It also demonstrated higher sensitivity (0.882; 95% CI: 0.725-0.967) and consistent performance in subgroups. COMPASS-HF effectively stratified risk of hospitalization for HF, with cumulative incidence rates of 31.9% in the high-risk group and 1.2% in the low-risk group. CONCLUSIONS: By combining clinical and proteomic variables, we developed a high-performance HF prediction model for T2DM, enabling precise risk stratification and informing early intervention strategies.

Humans

A bimodal large language model reduces misalignment in patient education: A double-blinded randomized trial.

BACKGROUND: Effective patient education requires accurate communication aligned with patients' emotional and semantical needs. Text-based large language models (LLMs) lack access to non-verbal cues, which may contribute to misaligned responses. METHODS: We evaluated emotional and semantic misalignment in a text-based LLM using 64,200 utterances from 16,583 patient education cases across six departments and three centers. Dolphin was developed integrating text and audio cues and evaluated through emotion recognition, semantic consistency assessment, branch-level ablations, and a double-blinded randomized trial against a matched text-based LLM comparator (Chinese Clinical Trial Registry: (ChiCTR2500095933). FINDINGS: The text-based LLM showed emotional misalignment in 36.7% of responses and semantic misalignment in 28.3% of cases, with higher misalignment under greater burden. Dolphin outperformed the text-based LLM in emotion recognition accuracy (0.886 vs. 0.713) and semantic consistency (84.9% vs. 82.1%; both adjusted p < 0.001). Ablations supported contribution of audio branches. Dolphin received higher expert ratings than the text-based LLM and human educators (all p < 0.001). In 555 patients, Dolphin was associated with greater patient satisfaction (98.6% vs. 93.8%), suggestion acceptance (76.1% vs. 58.9%; p < 0.001), proactive disclosure (44.6% vs. 26.5%; p < 0.001), and fewer 7-day unplanned recontact (12.9% vs. 22.9%; p = 0.002). No unsafe recommendations or safety events were identified. CONCLUSIONS: Compared with text-based LLM, Dolphin improved emotional-semantic alignment and patient-education outcomes, supporting bimodal alignment as a strategy for reducing misalignment-driven communication failures. FUNDING: National Natural Science Foundation of China, State Key Laboratory Special Fund, and Chinese Academy of Medical Sciences Innovation Fund.

Humans

Diagnostic performance of machine learning models versus established risk stratification for intracranial aneurysm rupture: a systematic review and bivariate meta-analysis.

BACKGROUND: Machine learning (ML) models have been proposed to improve the discrimination of intracranial aneurysm rupture status beyond established clinical risk stratification tools. However, reported performance is heterogeneous and the relative contribution of model architecture and feature dominance remains unclear. METHODS: We performed a Preferred Reporting Items for Systematic Reviews and Meta-Analyses-diagnostic test accuracy systematic review and diagnostic meta-analysis of studies evaluating ML models for intracranial aneurysm rupture discrimination. PubMed, Embase and CENTRAL were searched to February 2026. Sensitivity and specificity were pooled using a bivariate random-effects model, with summary receiver operating characteristic curves generated across training, internal testing and external validation datasets. Models were compared with regression-based approaches and Population, Hypertension, Age, Size of aneurysm, Earlier subarachnoid haemorrhage, Site of aneurysm (PHASES) scores. Subgroup and meta-regression analyses explored associations between algorithm family and feature domain. RESULTS: Sixty-two retrospective cohorts (29&#x2009;709 patients 209 models) met the inclusion criteria. In training datasets, pooled sensitivity and specificity for ML were 0.81 (95% CI 0.75 to 0.85)&#x2009;and 0.83 (0.80-0.86), with an area under the curve (AUC) of 0.878, exceeding PHASES (AUC 0.667). In testing datasets, ML retained higher discrimination (AUC 0.837) than regression models (0.806) and PHASES (0.646). In external validation, sensitivity was preserved (0.82), but specificity declined (0.66). Deep learning demonstrated the highest AUCs (training and testing). Incorporation of haemodynamic or radiomic features improved pooled discrimination relative to morphology alone. Evidence of small-study effects and mostly unclear Prediction Model Risk Of Bias Assessment Tool ratings were observed. CONCLUSIONS: ML approaches demonstrate higher pooled discrimination for aneurysm rupture status than conventional risk scores in retrospective datasets, but reduced external validation specificity and heterogeneity limit confidence for clinical translation. Prospective, externally validated, calibrated models are required before integration into routine cerebrovascular risk stratification.

Humans

Mortality of Individuals With PRNP Variants Associated With Prion Disease in the United States, 1998-2024.

BACKGROUND AND OBJECTIVES: To characterize the survival of individuals with pathogenic PRNP variants-including to estimate annual hazards, to judge the accuracy of previously reported survival data, and to evaluate the utility of public record searches in determining vital status. METHODS: In this single-center cohort study, we gathered data on individuals who received positive antemortem PRNP genetic tests at the US National Prion Disease Pathology Surveillance Center (NPDPSC), including both diagnostic tests in symptomatic individuals, and predictive tests in asymptomatic individuals. Genetic test and autopsy results were queried from the NPDPSC database, and public record searches were conducted using online tools. RESULTS: Four hundred four individuals received positive genetic test results. Of 206 cases symptomatic at the time of genetic testing, 188 are likely now deceased based on typical disease duration for their genetic variants. Combined autopsy and public record searches in combination confirmed 174 of these deaths, for an estimated 92.6% sensitivity. We evaluated the age-dependent penetrance of the reportedly highly penetrance variants D178N and E200K and the reportedly low-penetrance variant V210I. Among 99 initially asymptomatic individuals with the pathogenic E200K variant, more than 936 person-years of follow-up, 18 deaths were observed, significantly fewer than 27.4 expected according to life tables based on retrospective data. The age-dependent penetrance of E200K calculated from these longitudinal data was significantly lower than that from retrospective data, with 69% penetrance by age 80 and a median age at death of 75. For the pathogenic D178N variant, the median age at death was 57, which was numerically later, but not significantly different from, that seen in retrospective data. For V210I, just 2 deaths occurred, both after age 90, consistent with minimal penetrance. DISCUSSION: Our data support high penetrance of PRNP D178N and E200K variants and low penetrance of V210I. For E200K, the age at onset distribution appears to be shifted slightly later, and lifetime risk slightly lower, than previously reported. Autopsy data and public death records in combination were sensitive and concordant for determining long-term outcomes, but additional prospective data should be gathered to support future preventive trials.

Journal Article

Comfort and Usability of Digital Versus Conventional Custom-Fit Mouthguards: A Randomized Clinical Trial.

BACKGROUND/OBJECTIVES: The use of mouthguards protects teeth and the supporting tissues against impacts. Digital impressions and 3D-printed models can reduce manufacturing steps and minimize discomfort. This study evaluated the fit, comfort, and usability of custom-made mouthguards, obtained by conventional and digital workflow, in amateur athletes. MATERIALS AND METHODS: Amateur athletes were recruited for this randomized, double-blind, crossover clinical study. Each participant received two 4-mm-thick custom-fit mouthguards made of ethylene vinyl acetate (EVA) sheets using two protocols: conventional impression using alginate to produce dental stone cast (CMP) and intraoral digital scanning to produce 3D-printed resin models (DMP). Each mouthguard was worn during all training and matches over 3&#x2009;months. The order of mouthguard use was randomly assigned. Patient satisfaction with the impression protocol and mouthguard use, model accuracy, and mouthguard fit were assessed. RESULTS: Overall, 46 participants completed the study. The DMP protocol required less execution time (p&#x2009;=&#x2009;0.023), caused less discomfort (p&#x2009;=&#x2009;0.018), anxiety (p&#x2009;=&#x2009;0.008), nausea (p&#x2009;=&#x2009;0.027), difficulty breathing (p&#x2009;<&#x2009;0.001), and unpleasant taste (p&#x2009;=&#x2009;0.006) compared to the CMP protocol. The pain (p&#x2009;=&#x2009;0.971) perceived by the participants was similar in both impression protocols. The CMP-mouthguards were considered to be better fitting by the majority of participants (p&#x2009;=&#x2009;0.027). Between-group comparisons revealed that DMP-mouthguard caused less discomfort immediately postadaptation (p&#x2009;=&#x2009;0.034), with no significant differences observed at 30 or 90&#x2009;days. CONCLUSIONS: The digital workflow demonstrated to be efficient in the fabrication of mouthguards. Digital impression was more comfortable, requiring less execution time, with more accurate printed models and produced mouthguards with reported comfort and fit levels similar to those manufactured conventionally.

Humans

The prevalence of isthmic and degenerative lumbar spondylolisthesis: an analysis of 1376 patients.

INTRODUCTION: Typically, spondylolisthesis is an asymptomatic spinal condition that is often captured accidently in radiographic studies. The limited studies reviewing incidence primarily used lateral radiographs, which lack the granularity of advanced imaging. In response, computed tomography (CT) has been recommended to enhance the accuracy of spondylolisthesis diagnosis (degenerative versus isthmic). In the present study, we sought to determine the prevalence of isthmic and degenerative spondylolisthesis using CT imaging. METHODS: We conducted a retrospective study of 1,680 patients who underwent abdominal/pelvic CT scans at a single level-1 trauma center from January 1, 2017, to January 31, 2017. RESULTS: A total of 1,680 CT scans were screened, of which 1,376 patient scans met the inclusion criteria of having undergone complete imaging (axial and sagittal images). The average age of the study population was 57.1 (standard deviation, 18.7) years; 51.1% were female, and 83.2% were Caucasian. The prevalence of isthmic spondylolisthesis was 5.4% (n&#xa0;=&#xa0;71): 3.6% of cases were at the L5-S1 level, 2.1% were at the L4-L5 level, and 0.6% were at the L3-L4 level. The female-to-male ratio was 0.73:1. The prevalence of degenerative spondylolisthesis was higher at 21.5% (n&#xa0;=&#xa0;285), and the level most commonly affected was L4-L5 (11.8%), followed by L5-S1 (9.7%) and L3-L4 (4.6%). The female-to-male ratio was 1.3:1. There was a higher prevalence of degenerative spondylolisthesis in women at L4-L5 (51.2% vs. 35.6%; P&#xa0;<&#xa0;0.001). CONCLUSION: We found that degenerative spondylolisthesis was more prevalent, occurring primarily in older women, between the L4-L5 vertebrae. On the other hand, isthmic spondylolisthesis more commonly occurred within male patients between the L5-S1 vertebrae. Our study is one of the first to recognize a high rate of degenerative spondylolisthesis within the L5-S1 region, highlighting the utility of CT scan to visualize spinal translation. LEVEL OF EVIDENCE: IV.

Humans

Reliability, Device Agreement and Validity of Load-Velocity Profiles: A Systematic Review with Meta-analysis.

BACKGROUND: For a valid one-repetition maximum (1RM) prediction via load-velocity (LV) relationships, high reliability and accuracy must be assumed. OBJECTIVE: Since individual study results indicate ambivalent prediction, this systematic review and meta-analysis was designed to provide a updated and comprehensive overview, extending knowledge about the validity and reliability of commercially available velocity sensors in Part I and the validity and reliability of velocity-based 1RM prediction models in Part II. METHODS: A systematic literature search was conducted in PubMed/MEDLINE, Web of Science, and Scopus. Validity and/or reliability studies or velocity-based 1RM prediction evaluations were included. Methodological quality was assessed using adapted COSMIN. The analysis was performed for intraclass correlation coefficient (ICC), Lin's concordance correlation coefficient (CCC), and Pearson's correlation coefficient (r). The review was preregistered in PROSPERO (CRD42025634595). RESULTS: Sixty-three studies were included for sensor validity and reliability and 38 for 1RM prediction models. Part I: Velocity sensors demonstrated good-to-excellent pooled validity and device agreement (ICC&#x2009;=&#x2009;0.91-0.92 [0.83-0.97]; k&#x2009;=&#x2009;55 and 439, respectively); intra- and inter-day reliability were classified as good to excellent with ICC&#x2009;=&#x2009;0.90-0.91 [0.85-0.95] (k&#x2009;=&#x2009;228 and 608, respectively), with sensor technology moderating the results. However, substantial heterogeneity and wide ranges of study-level estimates indicated considerable variability across moderators, linear position transducer (LPT) generally showing more consistent performance than inertial measurement units (IMU). Part II: Velocity-based 1RM prediction showed ICCs&#x2009;=&#x2009;0.90 [0.83-0.94] (k&#x2009;=&#x2009;124) and ICC&#x2009;=&#x2009;0.91 [0.72-0.98] (k&#x2009;=&#x2009;9); for reliability and validity, respectively. DISCUSSION: Commercial velocity sensors generally provide high relative validity and reliability. Results varied depending on exercise complexity, intensity, sensor technology, and modeling approach. While velocity-based 1RM prediction demonstrated high average validity, large heterogeneity in lower body exercises significantly biased the results. Furthermore, the dearth of measurement error and agreement analyses prohibits final conclusions. CONCLUSION: Therefore, velocity-based monitoring and 1RM prediction require cautious interpretation, as sensor- and exercise-specific evidence remains limited.

Load&#x2013;velocity relationship

Clinical applications of digital twin technology in In Vitro Fertilisation.

BACKGROUND: Digital twin technology, originating from aerospace and manufacturing industries, has emerged as a transformative tool in healthcare. In vitro fertilisation (IVF) faces persistent challenges including suboptimal embryo selection, unpredictable treatment outcomes, and limited personalisation of protocols. Despite advances in assisted reproductive technology, existing literature exhibits fragmentation: artificial intelligence applications in embryo selection, ovarian stimulation, and endometrial assessment have been developed independently without systematic integration into comprehensive treatment frameworks. Digital twin technology offers unprecedented opportunities to create virtual replicas of biological systems, enabling real-time monitoring, predictive modelling, and personalised treatment strategies. AIM: This narrative review aims to critically examine the current applications of digital twin technology in IVF, evaluate its potential benefits and limitations, synthesize existing evidence into an integrative conceptual model, and identify future directions for implementation in reproductive medicine. METHOD: A comprehensive narrative review was conducted using PubMed, Scopus, Web of Science, and IEEE Xplore databases. A narrative review approach was selected over systematic review to accommodate the heterogeneity of evidence types in this emerging field, including theoretical frameworks, simulation studies, and proof-of-concept implementations that would be excluded from systematic reviews. Search terms included "digital twin," "IVF," "in vitro fertilisation," "assisted reproductive technology," "embryo selection," and "predictive modelling." Studies published between 2015 and 2025 were included, focusing on original research articles, systematic reviews, and proof-of-concept studies describing digital twin applications in reproductive medicine. RESULTS: Digital twin technology in IVF demonstrates significant potential across multiple domains including embryo development simulation, ovarian response prediction, endometrial receptivity modelling, and personalised stimulation protocols. Current applications integrate artificial intelligence, machine learning algorithms, time-lapse imaging, and omics data to create comprehensive virtual models. Early evidence suggests improvements in embryo selection accuracy, ovarian response prediction, and treatment protocol optimization, though large-scale randomized controlled trials remain limited. Implementation challenges include data integration complexity, computational requirements, regulatory considerations, and validation requirements. CONCLUSION: Digital twin technology represents a paradigm shift in IVF practice, offering personalised, predictive, and precision medicine approaches. This review synthesizes existing evidence to propose an integrative conceptual model for digital twin implementation across the IVF treatment spectrum, identifies critical knowledge gaps, and establishes research priorities to advance clinical translation. Despite current limitations, continued advancement promises improved success rates and patient outcomes.

Humans

Cine-derived mitral annular relaxation velocity for detection of preclinical left ventricular diastolic dysfunction.

OBJECTIVES: Imaging diastolic dysfunction in pre-clinical heart failure (HF) is challenging. We evaluated a novel cardiac MRI (CMR) biomarker, CMR e-prime (CMR-MARV), in patients at risk of HF. METHODS: In this substudy of the PARABLE trial (NCT04687111), 236 patients (71.6&#xa0;&#xb1;&#xa0;7.7&#xa0;years, 61.6% male) fulfilling trial-defined ALVDD citeria underwent CMR with measurement of mitral annular relaxation velocity (CMR-MARV) at four mitral annular anchor points. Diastolic strain rates from FT were also assessed. Twenty-five age- and sex-matched controls were included (73.8&#xa0;&#xb1;&#xa0;3.1&#xa0;years, 52% male). Group differences were tested with t-tests, diagnostic accuracy with ROC analysis, and predictors of diastolic dysfunction with adjusted logistic regression. RESULTS: Compared with controls, patients had significantly higher indexed maximal left atrial volume (LAVimax), LV end-diastolic and end-systolic volumes, and LV mass (all p&#xa0;<&#xa0;0.001). Of FT variables, only peak diastolic longitudinal velocity differed between groups (p&#xa0;<&#xa0;0.001). In multivariate models, CMR-MARV correlated with radial, circumferential, and longitudinal diastolic strain rates, radial and longitudinal diastolic velocities (all p&#xa0;<&#xa0;0.001), echocardiographic e' (r&#xa0;=&#xa0;0.20, p&#xa0;=&#xa0;0.007), LV mass (r&#xa0;=&#xa0;-0.18, p&#xa0;=&#xa0;0.008), LAVimax (r&#xa0;=&#xa0;-0.18, p&#xa0;=&#xa0;0.008), and NT-proBNP (r&#xa0;=&#xa0;-0.30, p&#xa0;<&#xa0;0.0001). LAVimax and CMR-MARV were strongly independently associated with ALVDD (AUC 0.89 and 0.76, respectively; p&#xa0;<&#xa0;0.0001). A combined model (LAVimax + CMR-MARV) achieved excellent discrimination (AUC 0.91, 95% CI 0.86-0.97, p&#xa0;<&#xa0;0.0001). Independent predictors included LAVimax, CMR-MARV, and peak diastolic longitudinal velocity (all p&#xa0;<&#xa0;0.001). CONCLUSION: CMR-MARV provides a simple cine-derived measure of longitudinal relaxation that correlates with established structural and biochemical markers of diastolic burden. Within an at-risk population, it offers incremental functional information beyond conventional parameters and may support multiparametric CMR phenotyping of preclinical diastolic dysfunction.

Aged

Comparison of a Modified Regimen of Prophylactic Phenylephrine Boluses Versus Variable Rate Infusion During Elective Cesarean Delivery Under Spinal Anesthesia: A Noninferiority Randomized Double-Blind Study.

BACKGROUND: Prophylactic phenylephrine boluses have been found to be as effective as variable rate infusions during elective cesarean delivery but require a higher number of physician interventions to maintain blood pressure near baseline values. Therefore, there is a need to find a feasible regimen of bolus administration that is equally efficacious to the infusion regimen while at the same time requires a comparable number of physician interventions and is thus non-inferior to the infusion regimen. METHODS: Healthy pregnant women with term, uncomplicated, singleton pregnancies undergoing elective cesarean delivery under spinal anesthesia were randomly divided into two groups. The Bolus group received a phenylephrine bolus 100 &#x3bc;g immediately after spinal anesthesia and then at every systolic blood pressure value <90% of the baseline. The infusion group received a prophylactic variable-rate infusion of phenylephrine beginning at 50 &#x3bc;g/min and titrated to maintain systolic blood pressure at 90-99% of baseline. The primary outcome was the number of physician interventions needed to maintain the target systolic blood pressure; the secondary outcomes included phenylephrine requirements, incidence of hypotension/hypertension/bradycardia, umbilical arterial and venous blood gas analysis, Apgar scores, and maternal complications. The primary outcome was analyzed in terms of non-inferiority using a non-inferiority margin of two interventions. RESULTS: Eighty patients were included in the study. The median (interquartile range [IQR]) number of physician interventions was 6 (5-8) in the infusion group and 3 (2-4) in the bolus group (P < .001). The difference of medians (95% confidence interval [CI]) between the two groups was -3 (-4 to -2). Phenylephrine requirements were higher in the infusion group (630 [426-765] &#x3bc;g) compared to the bolus group (300 [200-400] &#x3bc;g; P < .001). Blood pressure was higher at certain time points in the infusion group, but overall accuracy of blood pressure control was not different between the groups. Incidence of hypotension, hypertension, and bradycardia, neonatal outcomes, and maternal complications did not differ between the groups. CONCLUSIONS: The modified regimen of prophylactic boluses is non-inferior to variable rate prophylactic phenylephrine infusion in terms of physician interventions needed to maintain systolic blood pressure within the target range and maternal and neonatal outcomes.

Humans

Comparative evaluation of molecular technologies for the identification of prevalent non-tuberculous mycobacteria in pulmonary infections: a systematic review and meta-analysis.

BACKGROUND: The increasing prevalence of non-tuberculous mycobacteria pulmonary disease (NTM PD) is a burden to public health. Successful management of NTM PD critically depends on accurate species identification and reliable drug susceptibility testing to guide appropriate antibiotic therapy. Emerging molecular technologies offer rapid diagnostic solutions compared to conventional methods, but their performance varies. This study aims to provide a comprehensive evaluation of current molecular techniques for NTM identification and to present a global antibiotic resistance profile. METHODS: A systematic literature search was conducted in PubMed and Web of Science for studies published between 2005 and 2024. Studies applying molecular methods for NTM identification and resistance detection in humans were included. Data on study characteristics, diagnostic methods, sample types, sample sizes, identification sensitivity, and drug susceptibility results were extracted. Meta-analysis was performed using R with the meta4diag package. The quality of included studies was assessed using the QUADAS-2 tool. RESULTS: The analysis included 49 studies on NTM identification and 33 studies on antibiotic resistance. For species identification, all evaluated molecular technologies (MALDI-TOF MS, PCR-based methods, Sequencing, DNA chip, and DNA strip) demonstrated high pooled sensitivities (>0.92). Subgroup analysis revealed that sample type significantly affected performance for MALDI-TOF MS. Preliminary analysis of antibiotic resistance rates revealed varying patterns. For slowly growing mycobacteria, a significantly high Ethambutol resistance rate was observed in M. avium (69.20%). Among rapidly growing mycobacteria, resistance to Imipenem was notable (54.22%), and Clarithromycin resistance varied significantly within the Mycobacterium abscessus complex. CONCLUSION: Emerging molecular technologies have revolutionized the methodology for NTM identification with excellent performance. However, their performance can be influenced by sample type, particularly for MALDI-TOF MS. The alarming and heterogeneous antibiotic resistance patterns also highlight the critical need for rapid and accurate species identification and drug susceptibility testing to inform effective therapeutic strategies. Key messagesMolecular technologies demonstrate high accuracy for NTM identification.Antibiotic resistance is a serious concern with variations among NTM species and subspecies.Rapid and accurate species identification and drug susceptibility testing are crucial for guiding effective clinical management of NTM PD.

Humans

Diagnostic performance of intraoperative in vivo hyperspectral imaging for meningioma grading and molecular alterations: results from a prospective feasibility study.

OBJECTIVE: Hyperspectral imaging (HSI) is an emerging intraoperative, noninvasive, contrast agent-free imaging modality that enables quantitative assessment of tissue composition. The present study aimed to investigate whether HSI-derived tissue parameters correlate with WHO grade and molecular markers of aggressiveness in cranial meningiomas. METHODS: In this prospective study, intraoperative in vivo HSI was performed using the TIVITA tissue system, capturing spectral signatures between 500 and 1000 nm. Quantitative tissue parameters included tissue oxygen saturation (StO2), near-infrared perfusion index, organ hemoglobin index (OHI), and tissue water index (TWI). HSI parameters were correlated with histopathological WHO grade and molecular alterations, including CDKN2A/B deletion, TERT promoter mutation, and 1p/22q loss. Group differences were analyzed using one-way ANOVA, and diagnostic performance was assessed using receiver operating characteristic (ROC) analysis. RESULTS: Forty-six meningiomas were included, comprising WHO grade 1 (n = 35) and WHO grade 2-3 (n = 11) tumors. TWI was significantly higher in WHO grade 2-3 meningiomas compared with WHO grade 1 tumors (mean 0.49 [SD 0.12] vs 0.38 [SD 0.17], p = 0.048). ROC analysis demonstrated an area under the ROC curve (AUC) of 0.71 (95% CI 0.56-0.86, p = 0.036) for TWI in discriminating higher-grade disease. A TWI cutoff &#x2265; 0.367 identified all WHO grade 2-3 meningiomas with 100% sensitivity and 100% negative predictive value. In a molecular subgroup (n = 15), OHI appeared higher in tumors with homozygous CDKN2A/B deletion than in nondeleted tumors (mean 0.77 [SD 0.04] vs 0.62 [SD 0.10]). However, only 3 CDKN2A/B-deleted cases were available, and these findings should be considered descriptive. ROC analysis yielded an AUC of 0.89 (95% CI 0.71-1.00). An OHI cutoff &#x2265; 0.712 identified all three CDKN2A/B-deleted tumors (100% sensitivity), with 83.3% specificity and 86.7% accuracy. CONCLUSIONS: The present investigation demonstrated that HSI-derived tissue water and hemoglobin metrics provide biologically meaningful information in meningiomas. Low tissue water content appeared to rule out higher-grade diseases in this first subset cohort, while elevated hemoglobin showed a potential association with CDKN2A/B deletion in a small exploratory subgroup. These findings support the potential of HSI as a real-time noninvasive tool for intraoperative risk stratification and should be evaluated in large-scale studies. German Clinical Trials Register no. DRKS00036771 (www.drks.de).

Humans

PCa Detection in PI-RADS 4 and 5 Lesions: Comparison of [68Ga]Ga-PSMA-11 PET/CT-Guided Robot-Assisted Biopsy Versus mpMRI Cognitive-Fusion TRUS-Guided Prostate Biopsy.

Lesions with a Prostate Imaging-Reporting and Data System (PI-RADS) score of 4 or greater on multiparametric MRI (mpMRI) indicate a high likelihood of prostate cancer (PCa), and guidelines recommend a targeted biopsy. We aimed to compare the diagnostic performance of robotic arm-assisted [68Ga]Ga-PSMA-11 PET/CT-guided prostate biopsy (PGPB) with mpMRI-directed cognitive-fusion transrectal ultrasound-guided biopsy (MCFB) in biopsy-na&#xef;ve men with clinical findings suggestive of PCa. Methods: This prospective, single-center, randomized clinical trial (NCT05137561) enrolled biopsy-na&#xef;ve men age 50-90 y with elevated levels of prostate-specific antigen (&#x2265;4 ng/mL) and abnormal digital rectal examination findings. All participants underwent mpMRI, and those with a PI-RADS score of 4 or greater were randomized into 2 arms. In arm 1, participants underwent PGPB for a [68Ga]Ga-PSMA-avid lesion, and participants in arm 2 underwent MCFB. Participants in arm 1 with PET-negative findings subsequently underwent MCFB, and participants with negative biopsy results underwent PET and PGPB. The primary outcome was the detection of PCa. Secondary outcomes included complication rates and participant-reported pain. Result: Of the 267 participants enrolled, 81.3% (217) had lesions with a PI-RADS score of 4 or greater and were randomized to either PGPB (n = 112) or MCFB (n = 105). PCa was detected in 97.1% of participants (101/104) in arm 1 and 81.0% (85/105) in arm 2 (P < 0.05). PGPB showed higher diagnostic accuracy for PI-RADS 5 lesions (100% vs. 95.1%, P = 0.09). Major complications were observed in arm 2 only (n = 5). Arm 1 had significantly fewer complications (10.8% vs. 51.4%, P < 0.01), a lower median visual analog scale score for pain (3 vs. 5), and shorter procedure times. The core positivity rate was higher in arm 1 (60% &#xb1; 20%), despite obtaining fewer cores. Conclusion: [68Ga]Ga-PSMA-11 PGPB demonstrated higher diagnostic performance, fewer complications, and better tolerability compared with MCFB. This approach enables integrated diagnosis and staging, offering a promising alternative for efficient, safe, and accurate evaluation of prostate cancer.

Humans