Search PubMedSearch

SEARCH · Search PubMed

Results for “Assisted reproductive technology”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

363 records · Page 9Linked to original sources

Validated UPLC-MS/MS quantification and intracellular PK-PD Modeling of periplocin-related cardiac glycosides in H/R-injured H9c2 cells.

Reliable intracellular quantification is essential for characterizing the target-site disposition and exposure-response relationships of bioactive natural products. In this study, an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the simultaneous determination of periplocin and four related cardiac glycoside metabolites in H9c2 cell lysates. Acceptable linearity, precision, recovery, and stability were achieved for intracellular quantification. Cells were treated with each compound at 50 μM, and intracellular concentrations and cell viability were monitored over 48 h. In hypoxia/reoxygenation (H/R) -injured cells, the time to maximum intracellular concentration was shortened for all five compounds, indicating altered cellular disposition under injury conditions. Cell viability was improved by all compounds during the observation period. Pharmacokinetic-pharmacodynamic (PK-PD) integration was performed using a sigmoid Emax model, and acceptable model fits were obtained, with Akaike information criterion (AIC) values ranging from 79.22 to 130.46. Low apparent EC50 values were estimated under this single-dose design, whereas the estimated Ke0 values suggested delayed equilibration with the effect compartment. These findings indicate that sustained cytoprotective responses can be produced by periplocin and related metabolic markers in injured cardiomyocytes. This intracellular bioanalytical strategy provides a quantitative approach for linking cellular exposure to pharmacodynamic response and may support further evaluation of periplocin-related cardiac glycosides.

Tandem Mass Spectrometry

Quantifying the aromatic amino acid metabolome: UPLC-MS/MS analysis of aromatic amino acids and their host and co-metabolites in plasma.

Aromatic amino acids (AAAs), tryptophan, phenylalanine, and tyrosine along with their pathway metabolites have been implicated in the pathogenesis of diseases ranging from cardiovascular, neurological, inflammatory, and cancer diseases, among others. As such, the measurement of the primary AAAs, their host pathway metabolites, and microbiome derived co-metabolites in blood can provide a sensitive reflection of systemic health. The aim of the study was to develop a method for the quantification of 17 metabolites, the three AAAs and various of their metabolites in plasma using a high-throughput ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method. The method demonstrated a dynamic range (1 to 16,700 ng/mL), with detection limits (LOD) as low as 0.05 ng/mL. Quantification limits ranged from 3 to 5019 ng/mL (LLOQ) and up to 16,700 ng/mL (ULOQ). Recovery at LQC, MQC, and HQC was satisfactory and consistent across most metabolites, with significant matrix effects observed only for 4-ethylphenol sulfate. Furthermore, intra and inter-day accuracy and precision met all acceptance criteria at all quality control concentrations for most of the metabolites. Measurement of NIST SRM 1950 showcased the method's accuracy for most of the metabolites. Finally, the method was applied on the analysis of plasma samples from 55 individuals (13 males and 42 females) providing information on AAAs and their pathway metabolites relevant concentrations in human plasma.

Amino Acids, Aromatic

Effects of an actuated ankle exoskeleton on walking stability in healthy adults: a controlled laboratory study.

BACKGROUND: Ankle exoskeletons are widely used to reduce the metabolic cost of walking, yet their effects on walking stability during unperturbed gait remain insufficiently understood. Walking stability can be characterized using complementary measures that capture stride-to-stride variability, global temporal organization, and local dynamic stability. Understanding how walking with an actuated ankle exoskeleton system influences these different aspects of gait stability is essential for the safe design and control of wearable robotic devices. METHODS: Eighteen healthy adults walked on a treadmill at a constant speed (1.1&#xa0;m/s) with and without an actuated bilateral ankle exoskeleton in a randomized crossover design. Spatiotemporal variability was quantified using coefficients of variation (CoV) of stride length, step width, and stance ratio. Global gait stability was assessed using detrended fluctuation analysis of stride time. Local dynamic stability was evaluated using maximum Lyapunov exponent calculated for the trunk, hip, upper leg, lower leg, and foot. Paired-samples two-sided t-tests were used to compare conditions. RESULTS: Walking with the ankle exoskeleton resulted in increased stride-to-stride spatiotemporal variability, reflected by higher CoV values for stride length (p&#x2009;<&#x2009;0.001) and stance ratio (p&#x2009;=&#x2009;0.005), while mean stride length and step width remained unchanged. Mean stance ratio was reduced in the exoskeleton condition (p&#x2009;<&#x2009;0.001). Global gait stability did not differ between conditions, indicating preserved long-range temporal gait organization. Local dynamic stability increased at the lower leg (p&#x2009;<&#x2009;0.001) and foot (p&#x2009;=&#x2009;0.019) when walking with the exoskeleton. CONCLUSIONS: Walking with the actuated ankle exoskeleton alters gait control across multiple levels during steady walking. While stride-to-stride variability in stride length and stance ratio increased, global gait stability remained unchanged. Local dynamic stability was increased at the lower leg and foot, suggesting segment-specific effects of ankle-level assistance close to the assisted joint. However, these findings should be interpreted as the combined effect of wearing the exoskeleton and receiving active assistance, rather than the isolated effect of plantarflexion assistance. These&#xa0;results provide insight for the design and control of ankle exoskeletons with respect to stability-related effects during walking.

Humans

A STORM-based protocol for nanoscale imaging and quantitative analysis of protein-associated and phospholipid-associated structures in natural rubber.

Stochastic Optical Reconstruction Microscopy (STORM) enables nanoscale mapping of molecular components beyond the diffraction limit; however, its reproducible implementation in hydrophobic polymer matrices remains challenging because fluorescence-labeling specificity, fluorophore photoswitching, three-dimensional localization, chromatic registration, and quantitative image analysis must be carefully controlled. This protocol presents a standardized experimental workflow for dual-color labeling, astigmatism-based three-dimensional STORM acquisition, and quantitative analysis of protein-associated and phospholipid-associated structures in natural rubber (NR). The workflow covers sample pretreatment, Cy5 NHS ester labeling of protein-associated primary amines, DiI labeling of phospholipid-rich domains, STORM imaging-buffer preparation, three-dimensional single-molecule localization, dual-channel registration, generation of standardized xy projections, aggregate-size analysis, and projected lateral spatial correlation assessment. Reproducibility is supported by defined acquisition and localization criteria, three independent sample preparations with at least five fields of view analyzed per condition, and unlabeled, single-color, dye-only matrix, and processing-associated Cy5 controls. Mean lateral localization precisions of 11.8&#x202f;&#xb1;&#x202f;2.3&#x202f;nm for Cy5 and 13.5&#x202f;&#xb1;&#x202f;2.9&#x202f;nm for DiI were obtained, while two-dimensional Fourier ring correlation analysis of the xy projections yielded effective lateral image resolutions of approximately 25 and 28&#x202f;nm, respectively. Image-based particle segmentation and localization-coordinate-based density-based spatial clustering of applications with noise (DBSCAN) were applied to standardized xy projections as complementary quantitative approaches. Application of the protocol to untreated, centrifuged, and protease-treated NR samples demonstrated treatment-associated changes in the detected abundance and projected size distributions of protein- and phospholipid-associated aggregates, together with a non-monotonic change in their projected lateral spatial correlation. These observations describe alterations in nanoscale organization but do not, by themselves, establish stable protein-phospholipid complex formation. Unlike previous studies that primarily demonstrated the feasibility of STORM imaging in rubber materials, the principal contribution of this work is an end-to-end, step-by-step protocol incorporating defined controls, three-dimensional localization, image-quality metrics, chromatic-registration procedures, and complementary quantitative-analysis pipelines for non-expert users. The workflow may be adaptable to other hydrophobic polymers and soft-material systems after appropriate optimization and validation.

Rubber

Ecological Restoration of the Soil-Like Function in the Bauxite Residue: Natural Microbiomes Mediated Molecular Transformation of Dissolved Organic Matter.

Soilization of bauxite residues offers a scalable route for long-term carbon management and ecological restoration. However, the microbial processes that transform exogenous organic inputs into stable soil-like carbon pools remain poorly resolved. Here, we combined cross-ecosystem meta-analysis, machine-learning prediction, native synthetic community (SynCom) construction, 13C-labeled straw microcosms, field validation, Fourier transform ion cyclotron resonance mass spectrometry, and genome-resolved metagenomics to unravel microbiome-mediated carbon transformation at the dissolved organic matter (DOM) molecular scale. Our meta-analysis revealed that alkaline industrial wastes retained soil-like DOM signatures but were enriched in microbial humic- and protein-like components, indicating active yet incomplete carbon processing. Guided by these patterns, native SynCom inoculation increased 13C incorporation into total organic carbon (TOC) and dissolved organic carbon (DOC), enlarged biodegradable and adsorbable DOC fractions, and shifted DOM from recalcitrant aromatic pools toward oxygenated carbohydrate-, tannin-, and phenolic-like molecular classes. Genome-resolved analyses linked this transformation to complementary polymer degradation and nutrient-cycling functions across fungal and bacterial guilds, including enriched carbohydrate-active enzymes in straw-carbon-utilizing metagenome-assembled genomes. Null model and thermodynamic analyses further showed that microbial communities were constrained by homogeneous selection, whereas DOM molecules were diversified through variable selection and redox-dependent transformation. Field-scale validation confirmed that SynCom promoted TOC and DOC accumulation and humic-like, high-density DOM fractions under alkaline conditions. Together, these findings establish a mechanistic framework in which functional microbiomes couple plant carbon depolymerization, DOM molecular diversification, and mineral-interactive carbon stabilization, providing a microbiome-guided strategy for carbon sequestration and soilization in the bauxite residue.

Soil

A versatile reversed-phase liquid chromatography charged aerosol detection method for streamlined monitoring of QS-21 content and stability in liposomal adjuvant formulations.

Identifying and quantifying an active adjuvant along with its degradants in drug formulations is essential for ensuring the safety and efficacy of the drug product. QS-21 is a potent adjuvant that is being evaluated in several clinical trials and is currently formulated in licensed vaccines that protect against shingles, malaria, and RSV. In aqueous environments, QS-21 is subject to hydrolytic degradation that is influenced by pH and temperature, resulting in the formation of a degradant known as QS-21 Hydrolyzed Product, QS-21 HP, which can occur during manufacturing and/or prolonged storage. The intact QS-21 and QS-21 HP induce distinct immune response profiles, making it critical to monitor the degradation of QS-21 in vaccine adjuvant formulations. To date, there has been a paucity of reliable assays for QS-21, its isomers, and degradant QS-21 HP in liposomal adjuvant formulations available that can be transferred seamlessly in quality control (QC) environments. Herein, we introduce a simple and QC-friendly liquid chromatography coupled to a charged aerosol detector (LC-CAD) enabled by stationary phase screening combined with in silico method development optimization. The method exploits 2.7&#xa0;&#x3bc;m fused-core phenyl hexyl particles, ensuring its versatility in standard and ultra-high pressure LC systems. This approach demonstrates a high correlation between predicted retention time (RT) and experimental outcomes with overall &#x2206;RT&#xa0;<&#xa0;4%. In addition, this assay shows great linearity, precision, specificity, and accuracy to advance process development characterization of new vaccine formulations.

Liposomes

Simultaneous determination of imiquimod and terbinafine in skin permeation studies: Validation of a liquid chromatography method with fluorescence detection.

Chromoblastomycosis is a chronic, neglected subcutaneous mycosis posing significant therapeutic challenges. A topical strategy combining terbinafine (TBF), an antifungal, with imiquimod (IMQ), a TLR-7/8 agonist immunomodulator, has emerged a promising alternative. However, no validated analytical method is currently available to simultaneously quantify both drugs in skin, which is crucial for novel formulation development. This study reports the development and validation of a simple HPLC method with fluorescence detection (excitation 236&#xa0;nm, emission 340&#xa0;nm) for the simultaneous determination of TBF and IMQ extracted from porcine skin. Separation was achieved on a C8 reversed-phase column (125&#xa0;&#xd7;&#xa0;4.0&#xa0;mm, 5&#xa0;&#x3bc;m) using a mobile phase of methanol and water (60,40, v/v), both containing 0.1% formic acid at a flow rate of 0.8&#xa0;mL/min. The method showed excellent linearity (r&#xa0;>&#xa0;0.999) over 0.01-1.0&#xa0;&#x3bc;g/mL for IMQ and 0.1-2.0&#xa0;&#x3bc;g/mL for TBF. Intra- and inter-day precision demonstrated coefficients of variation below 5%, and recovery rates from skin (79-105%) confirmed accuracy. Limits of detection were 0.001&#xa0;&#x3bc;g/mL for IMQ and 0.004&#xa0;&#x3bc;g/mL for TBF, with quantification limits of 0.02&#xa0;&#x3bc;g/mL and 0.16&#xa0;&#x3bc;g/mL, respectively. This selective, sensitive, and reproducible method represents a valuable analytical tool for supporting the development and quality control of topical formulations for chromoblastomycosis and other fungal skin diseases.

Animals

Impact of adenosine in controlled aortic root reperfusion on clinical outcomes among patients undergoing valvular heart surgery.

BACKGROUND: Adenosine is a vital medication in cardiac surgery, particularly in valvular heart procedures. While its use has been linked to improved postoperative cardiac function in some studies, there remains significant uncertainty regarding the adenosine usage in aortic reperfusion phase. This lack of consensus poses challenges for surgeons, perfusionists, and anesthesiologists alike. This study aims to explore the impact of adenosine on clinical outcomes in patients undergoing valvular heart surgery. METHOD: This prospective randomized controlled trial was conducted over a three-month period. Sixty patients undergoing valvular heart surgery were enrolled using a continuous sampling method and randomly allocated into two equal groups of 30 patients each. The intervention group received adenosine-enriched aortic root reperfusion immediately prior to aortic declamping, while the control group underwent standard warm blood aortic root reperfusion. Both groups were matched for demographic and clinical characteristics to ensure comparability. RESULTS: Results indicated no significant differences in mean cardiopulmonary bypass (CPB) time, aortic cross-clamping duration, or mechanical ventilation between the intervention and control groups. However, the intervention group that received adenosine had a higher rate of antiarrhythmic agent usage in the operating room (P&#xa0;<&#xa0;0.05). Inotropic agent usage was similar in both groups during surgery and in the ICU. Additionally, laboratory parameters on the first day of ICU admission were comparable between groups. CONCLUSION: Results in the control group showed more favorable outcomes in terms of anti-arrhythmic drug usage, electroshock application, and arrhythmia prevalence. This study showed advantages for the standard warm blood aortic root reperfusion technique in managing post-operative cardiac rhythm disturbances, in comparison with the trial group.

Humans

Diagnostic Performance of Machine Learning for Systemic Lupus Erythematosus: Systematic Review and Meta-Analysis.

BACKGROUND: Early and accurate diagnosis of systemic lupus erythematosus (SLE) and its organ involvement is essential. Previous reviews of machine learning (ML) in SLE combined heterogeneous tasks and validation strategies and may have overinterpreted model performance. OBJECTIVE: This study evaluated the diagnostic performance of ML and deep learning (DL) models for 3 clinically distinct SLE-related tasks: SLE classification or diagnosis, lupus nephritis (LN) diagnosis, and neuropsychiatric systemic lupus erythematosus (NPSLE) discrimination. We also assessed methodological quality and certainty of evidence. METHODS: PubMed, Embase, Cochrane Library, Web of Science, and IEEE Xplore were searched from January 2014 to April 2026. Eligible peer-reviewed diagnostic accuracy studies developed or validated ML or DL models for 1 of the 3 prespecified tasks, used an accepted reference standard, and provided data for a 2&#xd7;2 contingency table. Bivariate random-effects meta-analyses with the Hartung-Knapp-Sidik-Jonkman adjustment were used to pool sensitivity and specificity. We reported 95% prediction intervals (PIs), assessed risk of bias using the Quality Assessment of Diagnostic Accuracy Studies for Artificial Intelligence tool (QUADAS-AI; Viknesh Sounderajah [Imperial College London]), and evaluated certainty of evidence using the Grading of Recommendations Assessment, Development, and Evaluation framework for diagnostic test accuracy. RESULTS: Twenty-nine studies were included: 17 for SLE classification, 5 for LN diagnosis, and 7 for NPSLE discrimination. In the primary task-stratified analysis, pooled sensitivity was 0.91 (95% CI 0.86-0.94; 95% PI 0.56-0.99), and pooled specificity was 0.94 (95% CI 0.91-0.96; 95% PI 0.69-0.99), with low heterogeneity (I&#xb2;=23.9% and 22.9%, respectively). DL models showed a sensitivity of 0.93 and specificity of 0.95, compared with 0.88 and 0.94 for traditional ML models. Certainty of evidence was high for most analyses but low for LN diagnosis because of inconsistency and imprecision. All studies were retrospective, and only 9 of 29 (31%) performed independent external validation. Overall risk of bias was high or unclear in 22 of 29 (75.9%) studies. No study reported model calibration, decision-curve analysis, or net clinical benefit. CONCLUSIONS: ML models showed promising diagnostic accuracy across 3 distinct SLE-related tasks, but wide PIs, limited external validation, and pervasive risk of bias restrict conclusions about real-world generalizability. Prospective multicenter studies with standardized tasks and reference standards, independent external validation, and formal assessment of calibration and clinical utility are required before clinical implementation.

Humans

A validated sensitive LC-MS/MS method and its application in elucidating the unique ocular pharmacokinetic profile of 0.01% atropine underpinning its clinical utility for myopia.

A sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated to quantify atropine in ten rabbit ocular tissues enabling systematic characterization of the ocular pharmacokinetic profile of 0.01% atropine sulfate eye drops after a single topical administration. The method demonstrated excellent linearity (coefficient of determination, R2&#xa0;&#x2265;&#xa0;0.9908) across all matrices, with lower limits of quantification (LLOQ) of 0.05&#xa0;ng/mL for most tissues and 0.10&#xa0;ng/mL for retina and lens; intra- and inter-day accuracy, precision, matrix effects, extraction recoveries, and stability all met the acceptance criteria. Following a single bilateral topical dose (50&#xa0;&#x3bc;L/eye) in New Zealand White rabbits, atropine distributed rapidly into all 12 ocular compartments (the sclera further divided into three anatomical regions) with marked heterogeneity-the highest exposures were found in conjunctiva and cornea, a distinct anterior-to-posterior concentration gradient was observed in the sclera, sustained retention was noted in the retina (mean residence time from zero to the last measurable time point, MRT0-t 3.30&#xa0;h), while aqueous and vitreous humor eliminated rapidly (elimination half-life, t&#x2081;/&#x2082;&#xa0;<&#xa0;0.7&#xa0;h), and all tissues except aqueous humor followed a two-compartment model. This validated method and the comprehensive pharmacokinetic data reveal that topically applied 0.01% atropine achieves sustained exposure in key myopia-regulating tissues (retina, choroid, posterior sclera) with low exposure in side-effect target tissues (iris, ciliary body, lens).

Animals

Development and validation of an LC-MS/MS method for the quantification of the KRASG12C inhibitor divarasib.

Divarasib is a newly developed covalent KRASG12C inhibitor, currently under clinical investigation in a phase 3 trial in patients with non-small cell lung cancer (NSCLC). At the moment, very limited pharmacokinetic data are publicly known. However, obtaining more insight into the pharmacokinetic properties of divarasib is important, since this may provide a better understanding of its efficacy and safety risks. Pre-clinical studies have been performed in mouse models to evaluate the effect of drug transporters and drug-metabolizing enzymes on the plasma exposure and tissue distribution of divarasib. Therefore, a reliable quantification method is required. To our knowledge, no bioanalytical assay of divarasib has been published yet. Therefore, in this study we developed and validated an assay to quantify divarasib in human plasma and in eight different mouse-related matrices, and partially in mouse plasma, using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method was initially evaluated over a concentration range of 1-10,000&#xa0;nM. However, due to carry-over observed at 10,000&#xa0;nM, the validated calibration range was established at 1-2000&#xa0;nM, with matrix-dependent LLOQs of 1-10&#xa0;nM. Erlotinib was used as an internal standard and acetonitrile was utilized to perform protein precipitation as sample pretreatment. Divarasib demonstrated stability in human plasma and in mouse plasma and tissue homogenates under various experimental conditions. A pilot in vivo study showed the applicability of our validated LC-MS/MS method. Ongoing clinical trials may collect plasma samples, and this developed method enables quantification of divarasib in both mouse and human plasma samples.

Animals

Smart crutch tipsTM real-time feedback improves adherence to partial weight-bearing protocols following lower extremity fracture surgery: a pilot study.

PURPOSE: To evaluate the effectiveness of Smart Crutch Tips&#x2122; in promoting adherence to prescribed early partial weight-bearing (PWB) protocols and to assess patient experience with real-time weight-bearing feedback during home rehabilitation. METHODS: Twenty patients with lower extremity fractures prescribed partial weight-bearing (PWB) were randomized into two groups utilizing real-time feedback crutch tips (RFC). The Intervention group (n&#x2009;=&#x2009;10) used Smart Crutch Tips&#x2122; (ComeBack Mobility Inc., Kiev, Ukraine), which provided real-time feedback on weight-bearing compliance. The Control group (n&#x2009;=&#x2009;10) also used crutches equipped with Smart Crutch Tips&#x2122;, but notifications were disabled, allowing passive data collection without patient feedback. Weight-bearing compliance was defined as the percentage of steps within &#xb1;&#x2009;10% of the prescribed target. Secondary outcomes included patient satisfaction and device usability assessed using the System Usability Scale (SUS) throughout the home rehabilitation period. RESULTS: The Intervention group demonstrated significantly greater PWB compliance compared with the Control group (73.6% vs. 21.1%, p&#x2009;<&#x2009;0.01). The Intervention group reported a mean SUS score of 84.25, indicating excellent usability. No device-related complications or adverse events were observed. Patient satisfaction, assessed through video interviews, was high, with participants in the Intervention group expressing a strong willingness to recommend the device to others with similar injuries and rating it 10 out of 10. CONCLUSION: Smart Crutch Tips&#x2122; significantly improved adherence to prescribed partial weight-bearing protocols following lower extremity fracture surgery. The RFC device demonstrated high usability, excellent patient satisfaction, and no device-related complications during home rehabilitation throughout the study period.

Humans

Angiotensin II regulates anxiety and social-affective top-down and bottom-up attention control in a sex-dependent manner.

BACKGROUND: The renin-angiotensin system (RAS) has been increasingly recognized as potent modulator of cognitive and affective functions, with angiotensin II type 1 receptor (AT1R) antagonists emerging as repurposing candidate for anxiety and stress-related disorders. However, it remains unclear whether transient AT1R blockade modulates emotional attentional control and whether these effects are sex-dependent. METHODS: We conducted a preregistered, randomized, double-blind, placebo-controlled pharmacological eye-tracking study in 79 healthy adults (males and females) and determined effects of transient AT1R blockade via losartan (50&#xa0;mg) on emotional attention control using a validated anti-saccade paradigm with social (emotional faces) and non-social stimuli. Treatment effects on state anxiety and oculomotor responses were characterized using traditional metrics and a novel trial-history informed dynamic control framework. RESULTS: Losartan reduced state anxiety irrespective of sex but induced sexually dimorphic effects on attentional control. In females, losartan enhanced performance by reducing endpoint error without altering latency. Conversely, in males, losartan increased endpoint error and prolonged latency of the first correct saccade. Trial-history analyses revealed losartan reduced error probabilities following errors and repeat trials in both sexes. Yet, following correct trials, females receiving losartan maintained lower error probabilities, while males exhibited higher errors, potentially reflecting failure to disengage from effortful control. CONCLUSIONS: The RAS modulates anxiety and attentional control, the latter sex-dependently. AT1R blockade reconfigures attentional processing and adaptive control, suggesting sex-specific therapeutic potential in disorders characterized by excessive anxiety and attentional dysregulation. CLINICAL TRIALS REGISTRATION: ClinicalTrials.gov; https://clinicaltrials.gov/;NCT06329050.

Humans

Changes in hippocampal functional connectivity and volume associated with cognitive improvement and decline in amnestic mild cognitive impairment following computerized cognitive training.

BACKGROUND: The hippocampus influences the outcomes of amnestic mild cognitive impairment (aMCI) and undergoes different changes during the cognitive decline or recovery of aMCI compared to elderly individuals with normal cognition, which may reveal disease-dependent neurodegeneration or plasticity. We first aimed to investigate the hippocampal changes associated with cognitive changes in aMCI using a combined case-control study design. METHODS: In total, 50&#x202f;aMCI individuals and 50 healthy controls (HCs) were recruited in Shenyang, China, and separately randomized into training and control groups: aMCI training group, aMCI no training group, HC training group, and HC no training group. The aMCI and HC training groups received computerized cognitive training (CCT) thrice weekly for 12 weeks. Cognitive assessments and MRI data were collected at baseline and follow-up. RESULTS: The primary outcome was significant CCT&#xd7;diagnosis interaction effect on the change in cognitive performance as measured by clock drawing test (CDT) scores (F&#x202f;=&#x202f;4.322, P&#x202f;=&#x202f;0.041); this interaction was driven by CCT specifically in aMCI (F&#x202f;=&#x202f;4.465, P&#x202f;=&#x202f;0.038). Significant CCT&#xd7;diagnosis interaction effects of right-hippocampal FC changes were observed in the bilateral precuneus/cuneus (Pvoxel<0.05) driven by CCT in aMCI (F&#x202f;=&#x202f;5.429, P&#x202f;=&#x202f;0.023), and in the left superior temporal gyrus/middle temporal gyrus (STG/MTG, Pvoxel<0.05), driven by CCT of only in HCs (F&#x202f;=&#x202f;6.587, P&#x202f;=&#x202f;0.013). A significant interaction effect of left-hippocampal FC changes were observed in the right triangular part of the inferior frontal gyrus (IFGtriang, Pvoxel<0.05), driven by CCT in aMCI and HCs (F&#x202f;=&#x202f;6.550, P&#x202f;=&#x202f;0.013; F&#x202f;=&#x202f;7.097, P&#x202f;=&#x202f;0.010). No significant interaction effect on the change in hippocampal GMV was noted (P&#x202f;>&#x202f;0.05). CONCLUSION: CCT can improve the visuospatial ability of aMCI, which is reflected by the CDT scores. CCT can alter hippocampal FC in the bilateral precuneus/cuneus, the right IFGtriang, and the left STG/MTG. The hippocampal GMV is difficult to change in both HCs and aMCI during the cognitive decline. REGISTRATION NUMBER: ChiCTR1900026849. DATE OF REGISTRATION: 24 October 2019 NAME OF TRIAL REGISTRY: Chinese Clinical Trial Registry (ChiCTR).

Humans

Determination of 13 per- and polyfluoroalkyl substances in human plasma samples using LC-MS/MS: application to capillary microsamples.

Per- and polyfluoroalkyl substances (PFAS) are chemicals widely applied in industrial processes and highly persistent in the environment, whose extensive use has been linked to adverse health effects. Venous plasma is the conventional matrix for PFAS assessment in blood, and LC-MS/MS is the most used quantification technique. Despite the relevance of this topic, biomonitoring data on human exposure to PFAS in Brazil remain limited. This study validated an LC-MS/MS method for determination of 13 PFAS in human plasma. Blood samples were collected from volunteers by phlebotomy, followed by protein precipitation with acetonitrile containing 1% formic acid (v/v) and solid-phase extraction. Chromatographic separation was achieved on an Acquity UPLC HSS T3 column. The assay was linear over a calibration range of 0.2-20&#xa0;ng/mL. Intra- and inter-assay precision (CV%) were within the ranges of 2.06-12.0% and 0.25-10.7%, respectively. As for accuracy, results were 89.0-112.9%. Matrix effect ranged from -1.31 to 0.05%. Stability after four freeze/thaw cycles and under autosampler conditions were also confirmed for all analytes. The method was applied to 40 paired venous and capillary plasma samples. Both measures exhibited high correlation (r&#xa0;=&#xa0;0.926). PFOS was the only compound detected at concentrations &#x2265;0.2&#xa0;ng/mL (LLOQ) in all samples, with capillary plasma concentrations of 0.85-13.50&#xa0;ng/mL. In summary, the method showed good validation performance and demonstrated the suitability of capillary plasma samples as an alternative matrix for PFAS quantification.

Humans

Pictographs: feasibility and acceptability of a novel method of newborn identification to reduce wrong-patient errors in the NICU.

Wrong-patient errors cause serious harm in newborns. These errors involve ordering and administering tests, procedures, medications, and breast milk to an unintended patient. Newborns receiving care in neonatal intensive care units (NICUs) are at particularly high risk. Although more distinct newborn naming conventions as recommended by the Joint Commission significantly reduce wrong-patient orders, name similarities among multiple-birth infants and truncation of differentiating information in some electronic health record (EHR) systems contribute to this persistent increased risk. Accordingly, novel newborn identifiers are urgently needed. We propose Pictographs&#xa0;-&#xa0;images that are appealing, recognizable, and appropriate&#xa0;-&#xa0;to serve as visual identifiers for newborns in NICUs. Pictographs are selected by caregivers, uploaded into the EHR, and displayed at bedside. As part of a multicenter randomized controlled trial assessing effectiveness of Pictographs to prevent wrong-patient order errors, we initially evaluated feasibility and acceptability of Pictographs at two study sites. Pictographs as novel visual identifiers for newborns in the NICU were generally well received by caregivers and clinicians, and the vast majority of caregivers selected a Pictograph for their infant(s), which was posted at the bedside and uploaded into the EHR. Ordering clinicians&#xa0;-&#xa0;the primary target of the intervention to prevent wrong-patient errors&#xa0;-&#xa0;recognized the potential for Pictographs to provide a visual cue when placing orders, particularly for multiple-birth infants. Here, we describe the rationale, implementation, framework, feasibility, usefulness, and acceptability of Pictographs among key stakeholders. If found effective for preventing wrong-patient errors, Pictographs could be adopted as a patient safety solution in hospitals worldwide.

Female

Emerging techniques of CRISPR/Cas system in antiviral therapy and diagnostics: Applications, limitations, and translational perspectives.

The CRISPR/Cas (clustered regularly interspaced short palindromic repeats) system is a versatile technology for developing antiviral medicines and editing viral genomes in both diagnostics and vaccine synthesis. Emerging insights into class 2 effectors, such as Cas9, Cas12, and Cas13, which target viral DNA and RNA, have revolutionized vaccines against viruses such as HIV, HPV, HBV, and EBV. Innovative diagnostic techniques such as SHERLOCK, DETECTR, and FELUDA have demonstrated system's diversity and accuracy in detecting the virus markers, supporting clinical decision-making, indicating adaptability and precision of CRISPR. This review critically evaluates CRISPR's role in RNA editing, emphasizing its importance for functional genomics and development of recombinant vaccines. Translational challenges are critically discussed, including off-target effects, delivery limitations, and ethical issues, for which unique approaches such as high-fidelity Cas variants, non-viral delivery systems, and bioethical frameworks are evaluated to address these limitations. This review also covers other social implications, such as accessibility and biosecurity risks, associated with CRISPR technologies Collectively, these advances underscore the transformative potential of CRISPR technologies in shaping next-generation antiviral diagnostics and therapeutics.

CRISPR-Cas Systems

SBUF-SMUF: On the path to the optimum hemofiltration technique in pediatric cardiopulmonary bypass: A randomized clinical trial.

BACKGROUND: Hemofiltration during pediatric cardiopulmonary bypass (CPB) is essential to mitigate hemodilution, inflammatory responses, and postoperative complications. Conventional ultrafiltration (CUF) is widely practiced, but novel methods such as subzero balanced ultrafiltration combined with simple modified ultrafiltration (SBUF-SMUF) may offer superior outcomes. OBJECTIVE: To compare the clinical efficacy and safety of CUF versus SBUF-SMUF in pediatric patients undergoing open-heart surgery. METHODS: In this prospective randomized, outcome-assessor-blinded clinical trial, 80 pediatric patients with congenital heart disease were allocated to either CUF (n = 40) or SBUF-SMUF (n = 40) during CPB. Baseline demographics, intraoperative characteristics, fluid balance, blood product utilization, and postoperative outcomes were assessed. Statistical analysis was conducted using independent t-tests, Chi-square tests, and Fisher's exact tests. Statistical significance was defined as a two-tailed p-Value of less than 0.05. RESULTS: Demographic and preoperative variables were comparable between groups. Mean fluid balance was significantly positive in the CUF group (+192.1 &#xb1; 178.8 mL) but negative in the SBUF-SMUF group (-105.0 &#xb1; 78.9 mL, p < 0.001). The SBUF-SMUF group required significantly less intraoperative PRBC (141.7 &#xb1; 70.2 vs. 261.0 &#xb1; 68.8 mL, p < 0.001) and postoperative FFP transfusion (2% vs. 10%, p = 0.020). Post-bypass hematocrit levels were higher (31.2% vs. 27.3%, p = 0.001) and extubation occurred earlier in the SBUF-SMUF group (1.05 &#xb1; 1.03 vs. 2.27 &#xb1; 2.37 days, p = 0.006). No significant differences were observed in potassium levels or incidence of acute kidney injury. CONCLUSION: The SBUF-SMUF technique is safe, effective, and superior to CUF in optimizing fluid balance, reducing blood product utilization, and facilitating earlier extubation in pediatric cardiac surgery. No additional risk of oliguria or electrolyte imbalance was observed compared to CUF. Its simplicity and reproducibility support its consideration as a standard approach in pediatric CPB.

Humans