Search PubMedSearch

SEARCH · Search PubMed

Results for “Cardiac surgical procedures”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

386 records · Page 8Linked to original sources

Sodium Glucose Co-Transporter 2 Inhibitors and Ventricular Arrhythmias in Patients with Type 2 Diabetes: A Systematic Review of Observational Studies.

BACKGROUND: Sodium glucose co-transporter 2 inhibitors (SGLT2i) may exert antiarrhythmic effects, but their association with ventricular arrhythmias remains unclear. OBJECTIVE: We conducted a systematic review to evaluate the association between SGLT2i use and the risk of ventricular arrhythmias, cardiac arrest, and sudden cardiac death compared with other antidiabetic medications or no SGLT2i use among patients with type 2 diabetes mellitus. METHODS: MEDLINE, EMBASE, and CENTRAL were searched for observational studies published between March 2013 and March 2026. Quality was assessed using the Risk of Bias In Non-Randomized Studies of Interventions (ROBINS-I) tool, alongside evaluation of pharmacoepidemiology-specific biases. RESULTS: A total of 17 studies (16 cohort and one nested case-control) were included. Based on ROBINS-I, seven studies had moderate, eight serious, and two critical risks of bias. Eleven studies had at least one pharmacoepidemiology-specific bias. For ventricular arrhythmias, estimates ranged from a protective effect (hazard ratio [HR] 0.20, 95% confidence interval [CI] 0.04-0.97) to a potential increased risk (odds ratio 1.87, 95% CI 0.89-3.95) with SGLT2i use. For cardiac arrest, estimates consistently reported a lower risk with estimates that ranged from HR 0.63 (95% CI 0.59-0.68) to HR 0.85 (95% CI 0.82-0.88). The only study on sudden cardiac death reported a potential risk reduction (HR 0.62, 95% CI 0.38-1.01). CONCLUSIONS: While the association between SGLT2i and ventricular arrhythmias remains inconsistent, the use of SGLT2i likely reduces cardiac arrest and may reduce sudden cardiac death, suggesting a possible protective effect on ventricular arrhythmias among patients with type 2 diabetes.

Journal Article

Fundamentals of pacemakers ECG interpretation - part 2.

BACKGROUND: Modern pacemakers incorporate arrhythmia-response algorithms, ventricular pacing minimization protocols, and safety mechanisms that generate ECG patterns indistinguishable from pathological AV block, sensing malfunction, or device-mediated tachycardia. Failure to recognize these algorithm-driven signatures leads to unnecessary interventions, misdiagnosis, and inappropriate device reprogramming. This manuscript is the second in a two-part series on pacemaker ECG interpretation. METHODS: We conducted a narrative review of peer-reviewed literature and device-specific documentation on algorithm-driven ECG behavior, synthesizing evidence across arrhythmia recognition, upper rate physiology, ventricular pacing minimization, mode switching, safety mechanisms, and hysteresis algorithms. RESULTS: Pacemaker-mediated tachycardia produces regular paced wide-complex tachycardia locked at the upper tracking rate, initiated by any event with retrograde VA conduction. Ventricular tachycardia is identified by QRS morphology diverging from the known paced pattern, absent pacing spikes, and AV dissociation. Upper rate Wenckebach behavior mimics Mobitz type I AV block; 2:1 upper rate response mimics second-degree AV block. Ventricular pacing minimization algorithms produce isolated nonconducted P waves and prolonged AV intervals that simulate pathological conduction disease. Mode switching causes abrupt rate drops misidentified as output failure. Ventricular safety pacing generates a conspicuously short, fixed AV interval. Three discrete pacing artifacts reflect AV-sequential cardiac resynchronization therapy (CRT), ventricular safety pacing in CRT, or His-bundle pacing with backup RV output. Rate and AV hysteresis produce pauses and wandering AV intervals mimicking oversensing or Wenckebach periodicity. CONCLUSIONS: Recognizing algorithm-driven ECG patterns requires knowledge of device timing intervals and refractory periods, which lets clinicians distinguish programmed behavior from true malfunction or cardiac arrhythmia.

Humans

Vaginal Hysterectomy Versus Vaginal Assisted Natural Orifice Transluminal Endoscopic Surgery Hysterectomy; Results of a Randomised Controlled Trial.

OBJECTIVE: To compare Vaginal Hysterectomy (VH) with Vaginal Assisted Natural Orifice Transluminal Endoscopic Surgery (NOTES) hysterectomy (VANH) as a day-care procedure. DESIGN: Single-blind, multicentre randomised controlled trial. SETTING: Two Dutch non-academic teaching hospitals. POPULATION: Women aged &#x2265;&#x2009;18&#x2009;years undergoing hysterectomy for benign indications. METHODS: Women were randomised 1:2 (VH or VANH). Primary outcome was SDD. Secondary outcomes included operative time, rate of elective salpingectomies, intraoperative blood loss, complications (Clavien-Dindo), pain scores (NRS) and analgesic use, post-operative recovery (RI-10), and quality of life (EQ-5D-5L). Analyses were performed on an intention-to-treat basis. RESULTS: A total of 113 patients were included in the analyses (n&#x2009;=&#x2009;42 VH, and n&#x2009;=&#x2009;71 VANH). SDD occurred significantly more frequently in the VANH group (87.3%) than VH group (71.4%; OR 2.76, 95% CI 1.04-7.25; p&#x2009;=&#x2009;0.04). VANH was associated with a significantly shorter operative time (median 55&#x2009;min versus 65&#x2009;min; p&#x2009;=&#x2009;0.005), less blood loss (median 50&#x2009;mL vs. 150&#x2009;mL; p&#x2009;<&#x2009;0.001) and more often elective opportunistic salpingectomy compared to VH (100% vs. 77.4%; p&#x2009;=&#x2009;0.008). NRS were significantly lower in the VANH group the first hour post-operative (3 vs. 1, p&#x2009;<&#x2009;0.001). Post-operative complications (VH 9.5% vs. VANH 15.5%; p&#x2009;=&#x2009;0.34), readmission (VH 4.8% vs. VANH 8.5%; p&#x2009;=&#x2009;0.47), analgesic use, recovery, and quality of life were not statistically significant. CONCLUSIONS: VANH is a safe and effective alternative to VH, offering a higher likelihood of SDD, shorter operative time, reduced blood loss, and more often an elective salpingectomy, without increased complications or differences in pain, recovery, or quality of life.

Humans

Astigmatic vector outcomes after FS-LASIK versus SMILE for high myopic astigmatism: a single-center retrospective comparative cohort study without cyclotorsion compensation.

PURPOSE: To compare astigmatic correction vector outcomes between femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and small-incision lenticule extraction (SMILE, also termed Keratorefractive Lenticule Extraction, KLEx) without intraoperative cyclotorsion compensation in patients with high myopic astigmatism (-&#x2009;2.00 to&#x2009;-&#x2009;3.75 D), and to clarify procedure-specific correction tendencies under this non-standardized alignment protocol. METHODS: This single-center retrospective comparative cohort study enrolled 155 eyes (one eye randomly selected per patient) that underwent FS-LASIK (80 eyes) or SMILE/KLEx (75 eyes) for high myopic astigmatism correction from January 2023 to July 2024 in Beijing Fenglian Jiayue Lige Clinic. Intraoperative cyclotorsion compensation was intentionally disabled to isolate inherent procedural astigmatism correction characteristics. Standardized Alpins vectorial analysis was performed at 3&#xa0;months and 12&#xa0;months postoperatively. PRIMARY ENDPOINT: 12-month Alpins correction index (CI). Multivariable propensity score adjustment was applied to mitigate confounding by clinical treatment selection bias. Statistical multiplicity control was implemented for secondary vector and visual outcomes. RESULTS: Baseline demographic, refractive, corneal and ocular biometric parameters were balanced between groups after propensity matching. No statistically significant intergroup differences were detected in uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), residual cylinder, safety index or efficacy index at 3 and 12&#xa0;months (all P&#x2009;>&#x2009;0.05). Under the non-cyclotorsion-compensated protocol, significant intergroup differences were identified in the magnitude of surgically induced astigmatism (SIA), correction index (CI), and magnitude error (ME) at both follow-up timepoints (all P&#x2009;<&#x2009;0.0001). Target induced astigmatism (TIA), difference vector (DV), index of success (IOS), and angle error (AE) magnitudes were comparable between groups (all P&#x2009;>&#x2009;0.05). The vector mean axis of DV differed significantly between groups at 3 and 12&#xa0;months (Watson-Williams circular test, all P&#x2009;<&#x2009;0.0001). No reoperations were documented in clinic medical records for either cohort. No standardized dry eye questionnaires, tear film testing or corneal nerve density metrics were collected to quantify dry eye adverse events; only unstructured clinical notes were reviewed for complication screening. CONCLUSIONS: Under surgical alignment without cyclotorsion compensation, FS-LASIK and SMILE/KLEx both yielded acceptable visual and refractive safety/efficacy for high myopic astigmatism (-&#x2009;2.00 to&#x2009;-&#x2009;3.75 D) at 1-year follow-up, but demonstrated divergent astigmatism correction tendencies: FS-LASIK exhibited relative astigmatism overcorrection (vector mean DV:&#x2009;-&#x2009;0.35&#x2009;&#xb1;&#x2009;0.43 D&#x2009;&#xd7;&#x2009;91&#xb0;, CI&#x2009;>&#x2009;1), while SMILE/KLEx showed relative undercorrection (vector mean DV:&#x2009;-&#x2009;0.21&#x2009;&#xb1;&#x2009;0.53 D&#x2009;&#xd7;&#x2009;12&#xb0;, CI&#x2009;<&#x2009;1). These correction biases are specific to the study's manual limbal alignment protocol without cyclotorsion tracking and cannot be generalized to modern optimized surgical platforms equipped with automated cyclotorsion compensation. Residual refractive errors across both groups are likely multifactorial, including differential corneal stromal healing responses, divergent femtosecond/excimer laser tissue modification mechanisms, and uncorrected intraoperative ocular cyclotorsion.

Humans

Enhanced risk stratification in hypertrophic cardiomyopathy through the integration of extracellular volume fraction on cardiovascular magnetic resonance.

AIMS: This study investigated the incremental prognostic value of cardiovascular magnetic resonance (CMR)-derived extracellular volume fraction (ECV), a marker of diffuse interstitial fibrosis, beyond late gadolinium enhancement (LGE) in hypertrophic cardiomyopathy (HCM). METHODS AND RESULTS: We analysed 990 consecutive HCM patients (median age 58 years, male 68.3%) who underwent CMR between 2012 and 2024. LGE and global ECV were quantified, and their associations with the primary endpoint of HCM-related events-a composite of sudden cardiac death (SCD) events, heart failure (HF) events, and HCM-related death-were assessed. During a median follow-up of 3.2 years, 64 (6.5%) patients experienced the primary endpoint. While LGE (median 7.1%, IQR 2.3-16.9%) and ECV (median 29.0%, IQR 26.6-32.0%) were moderately correlated (R = 0.604, P < 0.001), both were significantly associated with increased risk of the primary endpoint and individual outcomes of SCD and HF events, and optimal cutoffs were determined as LGE &#x2265; 27% and ECV &#x2265; 35%. Patients with ECV &#x2265; 35% had more symptoms, a more severe phenotype with greater systolic and diastolic dysfunction, and more pathogenic gene variants. Notably, ECV remained a significant predictor of the primary endpoint (adjusted HR 1.08, 95% CI 1.02-1.15, per 1%) after adjustment for key disease variables, including left ventricular ejection fraction and LGE. Elevated ECV effectively identified high-risk individuals even among lower-risk subgroups, including those with low LGE burden. CONCLUSION: Increased ECV is an independent predictor of HCM-related outcomes. ECV may serve as a novel imaging biomarker to refine risk stratification in HCM patients who do not meet traditional LGE-based high-risk criteria.

Humans

Impact of subthreshold troponin levels and temporal trends on short term adverse cardiovascular outcomes in patients discharged from the emergency department: a RACE-IT trial substudy.

BACKGROUND: High-sensitivity cardiac troponin I assays enable early exclusion of myocardial infarction in the emergency department. However, the clinical implications of detectable troponin values below the 99th percentile upper reference limit (4-18 ng/L) remain unclear. OBJECTIVE: To assess the association between subthreshold troponin levels and 30-day outcomes in patients from the RACE-IT trial, using exact troponin values when available. METHODS: This post-hoc analysis of the RACE-IT stepped-wedge randomized controlled trial included patients with troponin&#x2009;&#x2264;&#x2009;18 ng/L across nine EDs. Patients were stratified by initial troponin, peak value, absolute change, and percent change. The primary outcome was a 30-day composite of all-cause death, acute MI, percutaneous coronary intervention, and coronary artery bypass grafting. Logistic regression analysis after adjusting for age, sex, race, and coronary artery disease was performed. RESULTS: Among 19,194 patients with troponin&#x2009;&#x2264;&#x2009;18 ng/L, 117 (0.6%) experienced the composite outcome. Higher troponin levels were associated with increased event rates in unadjusted analyses. Adjusted analyses showed no independent associations overall, though patients whose highest troponin values fell within the&#x2009;&#x2265;&#x2009;11-&#x2009;&#x2264;&#x2009;18 ng/L range continued to demonstrate significantly worse outcomes than those with lower peak levels. Elevated troponin values correlated with older age, male sex, and greater comorbidity burden. CONCLUSION: In this post-hoc analysis of patients with troponin values below the 99th percentile URL, absolute levels and temporal changes were not independently associated with 30-day adverse outcomes. These findings support the use of subthreshold troponin values in rapid rule-out protocols, emphasizing the need to consider clinical context and comorbidities in risk assessment.

Humans

SBUF-SMUF: On the path to the optimum hemofiltration technique in pediatric cardiopulmonary bypass: A randomized clinical trial.

BACKGROUND: Hemofiltration during pediatric cardiopulmonary bypass (CPB) is essential to mitigate hemodilution, inflammatory responses, and postoperative complications. Conventional ultrafiltration (CUF) is widely practiced, but novel methods such as subzero balanced ultrafiltration combined with simple modified ultrafiltration (SBUF-SMUF) may offer superior outcomes. OBJECTIVE: To compare the clinical efficacy and safety of CUF versus SBUF-SMUF in pediatric patients undergoing open-heart surgery. METHODS: In this prospective randomized, outcome-assessor-blinded clinical trial, 80 pediatric patients with congenital heart disease were allocated to either CUF (n = 40) or SBUF-SMUF (n = 40) during CPB. Baseline demographics, intraoperative characteristics, fluid balance, blood product utilization, and postoperative outcomes were assessed. Statistical analysis was conducted using independent t-tests, Chi-square tests, and Fisher's exact tests. Statistical significance was defined as a two-tailed p-Value of less than 0.05. RESULTS: Demographic and preoperative variables were comparable between groups. Mean fluid balance was significantly positive in the CUF group (+192.1 &#xb1; 178.8 mL) but negative in the SBUF-SMUF group (-105.0 &#xb1; 78.9 mL, p < 0.001). The SBUF-SMUF group required significantly less intraoperative PRBC (141.7 &#xb1; 70.2 vs. 261.0 &#xb1; 68.8 mL, p < 0.001) and postoperative FFP transfusion (2% vs. 10%, p = 0.020). Post-bypass hematocrit levels were higher (31.2% vs. 27.3%, p = 0.001) and extubation occurred earlier in the SBUF-SMUF group (1.05 &#xb1; 1.03 vs. 2.27 &#xb1; 2.37 days, p = 0.006). No significant differences were observed in potassium levels or incidence of acute kidney injury. CONCLUSION: The SBUF-SMUF technique is safe, effective, and superior to CUF in optimizing fluid balance, reducing blood product utilization, and facilitating earlier extubation in pediatric cardiac surgery. No additional risk of oliguria or electrolyte imbalance was observed compared to CUF. Its simplicity and reproducibility support its consideration as a standard approach in pediatric CPB.

Humans

Editorial Commentary: Stiff Patients After Rotator Cuff Repair: How Many Had Underrecognized Preoperative Adhesive Capsulitis?

Stiffness after rotator cuff repair is one of the most common sources of disability and one of the most common complications. Smoking, diabetes, Workers' compensation status, and traumatic tears are among the strongest risk factors. This is important information in setting appropriate expectations for both the patient and the surgeon preoperatively. Some of these factors are also associated with preoperative stiffness, so surgeons should maintain a high index of suspicion for concomitant adhesive capsulitis in patients presenting with limited motion, particularly in diabetic and non-English speaking populations. In cases where both a rotator cuff tear and adhesive capsulitis coexist, performing a concurrent capsular release or manipulation during the index procedure may improve functional outcomes and reduce the necessity for secondary surgical intervention.

Humans

Cine-derived mitral annular relaxation velocity for detection of preclinical left ventricular diastolic dysfunction.

OBJECTIVES: Imaging diastolic dysfunction in pre-clinical heart failure (HF) is challenging. We evaluated a novel cardiac MRI (CMR) biomarker, CMR e-prime (CMR-MARV), in patients at risk of HF. METHODS: In this substudy of the PARABLE trial (NCT04687111), 236 patients (71.6&#xa0;&#xb1;&#xa0;7.7&#xa0;years, 61.6% male) fulfilling trial-defined ALVDD citeria underwent CMR with measurement of mitral annular relaxation velocity (CMR-MARV) at four mitral annular anchor points. Diastolic strain rates from FT were also assessed. Twenty-five age- and sex-matched controls were included (73.8&#xa0;&#xb1;&#xa0;3.1&#xa0;years, 52% male). Group differences were tested with t-tests, diagnostic accuracy with ROC analysis, and predictors of diastolic dysfunction with adjusted logistic regression. RESULTS: Compared with controls, patients had significantly higher indexed maximal left atrial volume (LAVimax), LV end-diastolic and end-systolic volumes, and LV mass (all p&#xa0;<&#xa0;0.001). Of FT variables, only peak diastolic longitudinal velocity differed between groups (p&#xa0;<&#xa0;0.001). In multivariate models, CMR-MARV correlated with radial, circumferential, and longitudinal diastolic strain rates, radial and longitudinal diastolic velocities (all p&#xa0;<&#xa0;0.001), echocardiographic e' (r&#xa0;=&#xa0;0.20, p&#xa0;=&#xa0;0.007), LV mass (r&#xa0;=&#xa0;-0.18, p&#xa0;=&#xa0;0.008), LAVimax (r&#xa0;=&#xa0;-0.18, p&#xa0;=&#xa0;0.008), and NT-proBNP (r&#xa0;=&#xa0;-0.30, p&#xa0;<&#xa0;0.0001). LAVimax and CMR-MARV were strongly independently associated with ALVDD (AUC 0.89 and 0.76, respectively; p&#xa0;<&#xa0;0.0001). A combined model (LAVimax + CMR-MARV) achieved excellent discrimination (AUC 0.91, 95% CI 0.86-0.97, p&#xa0;<&#xa0;0.0001). Independent predictors included LAVimax, CMR-MARV, and peak diastolic longitudinal velocity (all p&#xa0;<&#xa0;0.001). CONCLUSION: CMR-MARV provides a simple cine-derived measure of longitudinal relaxation that correlates with established structural and biochemical markers of diastolic burden. Within an at-risk population, it offers incremental functional information beyond conventional parameters and may support multiparametric CMR phenotyping of preclinical diastolic dysfunction.

Aged

Nerve injury in revision total elbow arthroplasty: a systematic review and meta-analysis.

BACKGROUND: Revision total elbow arthroplasty (TEA) is technically demanding and carries a substantial risk of postoperative neurological complications because of scarring, altered anatomy, implant removal, and repeated humeral and ulnar exposure. The incidence, nerve distribution, and recovery profile of nerve injury after revision TEA remain incompletely defined. This study aimed to systematically review the literature to define the incidence, recovery profile, and risk factors for nerve injury after revision TEA. METHODS: A systematic review of the literature was performed in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidance. Thirteen retrospective case series were included, comprising 282 revision TEAs in 271 patients. Random-effects meta-analysis of proportions was undertaken where the data permitted. The primary outcome was postoperative nerve injury following revision TEA. Secondary outcomes included nerve type, recovery, secondary nerve-related procedures, infection, triceps insufficiency, metallosis, periprosthetic fracture, and re-revision. RESULTS: The pooled incidence of postoperative nerve injury was 22.3% (95% confidence interval [CI] 16.3 to 29.6; I2 = 34.6%). The crude incidence was 60 of 282 revisions (21.3%, 95% CI 16.6 to 26.5). The ulnar nerve was involved in 66.7% of all nerve injuries, the radial nerve in 31.7%, and the median nerve in 1.7%. No significant difference in pooled nerve-injury incidence was identified between studies published before 2010 and those published from 2010 onwards (22.9% vs. 21.4%, P = .837). Recovery reporting was heterogeneous; among injuries with numerically extractable outcomes, 85.4% improved partially or completely (95% CI 72.2 to 93.9). Secondary nerve-related procedures were reported in 7 studies. Pooled complication estimates were 10.2% for infection, 13.6% for triceps insufficiency, 25.5% for metallosis, 15.9% for periprosthetic fracture, and 14.0% for re-revision. CONCLUSIONS: Postoperative nerve injury is a common and clinically important complication of revision TEA, affecting approximately 1 in 5 cases. The ulnar nerve is most frequently involved, although radial nerve injury accounts for a substantial proportion of cases. Many neuropathies improve during follow-up, but persistent deficits and the need for secondary nerve-related procedures are not uncommon. Future studies should adopt standardized neurological definitions and reporting to improve comparability and guide preventive surgical strategies.

Humans

Recurrent myocardial infarction identified by centralized troponin review: Insights from the MINT trial.

BACKGROUND: The utility of routine troponin testing to identify recurrent myocardial infarction (MI) after an incident MI is unclear. We assessed the incidence and prognosis of recurrent MIs identified from centralized troponin review in patients from the Myocardial Ischemia and Transfusion (MINT) trial. METHODS: The MINT trial randomized patients with acute MI and anemia to a liberal vs restrictive red blood cell transfusion strategy. Suspected recurrent MIs were identified through both site-report and centralized review of troponin levels collected for 3 days following randomization. Differences in cardiac, noncardiac, and all-cause death at 30 and 180 days were compared across patients with any site-reported MI, only centrally identified MI, and no recurrent MI. RESULTS: Among 3,504 patients, 275 (7.8%) had a recurrent MI within 30 days; 119 (43.3%) by site-report, and 156 (56.7%) by central troponin review only. Rates of cardiac and all-cause death at 30 and 180 days were highest for patients with site-reported MI, intermediate for centrally identified MI, and lowest for no recurrent MI; rates of noncardiac death did not vary. Patients with only centrally identified recurrent MI had an increased risk of cardiac death at 30 days (RR 1.9, 95% CI 1.0-3.4) and 180 days (RR 1.7, 95% CI 1.1-2.7) compared to those without recurrent MI. CONCLUSIONS: In patients with acute MI and anemia, centralized troponin review identified more than half of all recurrent MI events. Patients with centrally identified MI had a higher risk of cardiac death than those with no recurrent MI. TRIAL REGISTRATION: ClinicalTrials.gov NCT02981407 https://clinicaltrials.gov/study/NCT02619136.

Humans

Effect of Roux-en-Y Gastric Bypass and Sleeve Gastrectomy on Male Sexual Function: A Systematic Review and Meta-Analysis.

BACKGROUND: Obesity negatively impacts male sexual function and fertility through hormonal imbalances, endothelial dysfunction, and psychosocial factors. Metabolic and bariatric surgery (MBS) constitutes an effective intervention; however, procedure-stratified changes in male reproductive parameters after Roux-en-Y gastric bypass (RYGB) and sleeve gastrectomy (SG) remain incompletely synthesized. METHODOLOGY: A systematic search of PubMed, Embase, Cochrane Library, Scopus, and Web of Science was conducted in November 2024. Sexual function, testosterone levels, and semen quality were included. Risk of bias was assessed using MINORS criteria. Random-effects meta-analyses were performed separately for each surgical modality, with heterogeneity quantified via I2 statistics. RESULTS: Twenty-one studies comprising 848 patients were included. Meta-analysis of pre-post data demonstrated that both RYGB and SG were independently associated with improvements in sex hormone-binding globulin and testosterone levels. In studies examining SG, significant improvements were observed in erectile function (SMD: 1.38, 95% CI: 0.66-2.10, p&#x2009;=&#x2009;0.0002) and sperm concentration (SMD: 0.91, 95% CI: 0.56-1.26, p&#x2009;<&#x2009;0.00001). Studies evaluating RYGB did not demonstrate statistically significant changes in erectile function (SMD: 0.62, 95% CI: -0.06 to 1.30, p&#x2009;=&#x2009;0.07) or sperm concentration (SMD: -0.01, 95% CI: -0.45 to 0.42, p&#x2009;=&#x2009;0.95). CONCLUSION: The meta-analytical findings suggest beneficial effects of both RYGB and SG on male hormonal parameters. Studies of SG demonstrated significant improvements in erectile function and sperm concentration. However, direct comparative analyses between the two procedures were not performed, precluding definitive conclusions regarding their relative efficacy. Future research necessitates head-to-head comparisons with standardized reproductive endpoints and extended follow-up periods.

Humans

Conduction System Pacing Versus Right Ventricular Pacing in Patients With Atrioventricular Block and Anticipated High Pacing Burden.

Right ventricular pacing (RVP) in patients with atrioventricular (AV) block and high anticipated pacing burden is associated with pacing-induced cardiomyopathy (PICM) in approximately 12% to 20% of patients, whereas conduction system pacing (CSP) preserves more physiologic ventricular activation and may mitigate these consequences; the totality of contemporary randomized evidence has not been systematically pooled. We conducted a systematic review and meta-analysis of randomized controlled trials (RCTs) comparing CSP with RVP in patients with AV block or anticipated high ventricular pacing burden and a minimum 6-month follow-up, with co-primary outcomes of PICM incidence and change in left ventricular ejection fraction (&#x394;LVEF) and secondary outcomes of heart failure hospitalization (HFH), all-cause mortality, composite clinical endpoint, and paced QRS duration (PROSPERO CRD420261400227); random-effects meta-analysis used DerSimonian-Laird estimation. Five RCTs (LBBP-FAVOUR, CSPACE, Prague CSP, PACE-HF, STAY; N = 806) met inclusion criteria. CSP significantly reduced PICM (hazard ratio [HR] 0.30, 95% confidence interval [CI] 0.18 to 0.48; p <0.001; I&#xb2; = 0%; k = 4), was associated with greater LVEF preservation (pooled mean difference [MD] +4.41%, 95% CI +1.82 to +6.99; p = 0.001; I&#xb2; = 87%; k = 5), and reduced HFH (HR 0.24, 95% CI 0.12 to 0.48; p <0.001; I&#xb2; = 0%; k = 5). CSP shortened paced QRS duration (MD -27.5 ms, 95% CI -32.6 to -22.5; p <0.001; k = 5). All-cause mortality was numerically lower with CSP but did not reach significance (HR 0.57, 95% CI 0.29 to 1.12; p = 0.10; k = 4). In a prespecified sensitivity analysis restricting to multicenter trials with N &#x2265; 150, all findings were concordant with the primary analysis. In conclusion, CSP substantially reduces PICM, preserves LVEF, and reduces HFH compared with RVP in patients with AV block and anticipated high pacing burden, supporting its consideration as the preferred pacing strategy in appropriately selected patients.

Humans

Premeal insulin administration lowers postprandial blood glucose and increases myocardial microvascular blood flow in people with type 1 diabetes: a randomised, crossover clinical trial.

AIMS/HYPOTHESIS: We aimed to evaluate whether prandial insulin timing affects vascular function in people with type 1 diabetes. Our hypothesis was that premeal insulin administration would lead to greater myocardial microvascular blood flow (MBF) via blunting postprandial hyperglycaemia. METHODS: People with type 1 diabetes between 18 and 35 years of age with BMI <30 kg/m2 underwent two protocols with a 1:1 randomised crossover design wherein prandial insulin was injected either 15 min before or 15 min after meal intake began. To provide a physiological comparison, age-, sex- and BMI-matched control participants completed one study where they consumed the same meal but received no exogenous insulin. Glucose, insulin, vascular function (including ultrasound measures of myocardial and skeletal muscle microvascular perfusion, aortic stiffness, brachial artery endothelial function) and biomarkers of systemic inflammation and endothelial dysfunction were assessed at baseline and then 2 h after meal ingestion within each protocol. The primary outcome was change in myocardial MBF within each protocol. Study personnel assessing outcomes were masked to group assignment. RESULTS: Eighteen people with type 1 diabetes and 18 matched control participants were analysed within each protocol. Glucose area under the curve was significantly greater (p=0.015) in the postmeal insulin study compared with the premeal insulin study in participants with type 1 diabetes. Myocardial microvascular flow velocity significantly increased (p=0.031) with premeal insulin administration in people with type 1 diabetes and this consequently led to greater myocardial MBF (p=0.044). There were no changes in myocardial MBF within the other protocols. Changes in vital signs were similar between all protocols. CONCLUSIONS/INTERPRETATION: Appropriately timed premeal insulin led to lower postprandial blood glucose along with increased myocardial MBF in people with type 1 diabetes. Further work is needed to determine the underlying aetiology of these changes. TRIAL REGISTRATION: ClinicalTrials.gov NCT04730882.

Humans

Characteristics of post-exercise responders versus non-responders following aerobic or isometric exercise in physically inactive adults of African and South Asian descent with high-normal blood pressure or grade I hypertension.

OBJECTIVE: To investigate interindividual variability in post-exercise hypotension (PEH) and to characterise cardiovascular and autonomic differences between responders and non-responders following aerobic and isometric exercise in adults of African and South Asian descent with elevated blood pressure (BP). METHODS: Physically inactive adults of African and South Asian descent living in Suriname (18-65&#x2009;years) with high-normal BP or grade I hypertension participated in a randomised controlled crossover trial. In this randomised cross-over trial, 47 adults (50.1&#x2009;&#xb1;&#x2009;10.8&#x2009;years; 38% male) with high-normal blood pressure or grade I hypertension completed three conditions: aerobic exercise (30&#x2009;min at 40-60% heart rate reserve), isometric handgrip exercise, and a non-exercise control. Ambulatory BP was assessed over 24&#x2009;h. PEH was defined as the net effect: (post-exercise&#x2009;-&#x2009;pre-exercise) - (post-control&#x2009;-&#x2009;pre-control). Participants were classified as responders if daytime BP decreased &#x2265;5&#x2009;mmHg. Arterial stiffness, cardiac, and autonomic parameters were assessed. RESULTS: Following aerobic exercise, 46% of participants were classified as systolic responders compared with 28% after isometric exercise. No baseline differences were observed in demographic or clinical characteristics between responders and non-responders, suggesting that PEH variability may reflect underlying physiological rather than clinical differences. Aerobic responders demonstrated greater reductions in aortic augmentation index (-19.4% vs. -10.9%, p&#x2009;=&#x2009;0.05), larger increases in stroke volume (+8.1 vs. -5.3&#x2009;mL, p&#x2009;=&#x2009;0.05) and cardiac output (+1.54&#x2009;&#xb1;&#x2009;1.89 vs. +0.58&#x2009;&#xb1;&#x2009;1.60&#x2009;L/min, p&#x2009;=&#x2009;0.009), and more favourable autonomic recovery. Among all variables, only the change in cardiac output was associated with PEH magnitude (r&#x2009;=&#x2009;-0.46, p&#x2009;=&#x2009;0.006). No consistent physiological differences were observed following isometric exercise. CONCLUSION: PEH following aerobic exercise is characterised by a distinct responder phenotype associated with greater reductions in aortic augmentation index and favourable cardiac adaptations. These findings highlight substantial interindividual variability in BP responses and support the need for individualised exercise strategies in hypertension management.

Adolescent

Accelerated Diagnostic Pathways for Suspected Acute Coronary Syndrome in Practice: A Randomized Trial of 0/1-Hour vs 0/3-Hour Troponin Testing.

BACKGROUND: For suspected acute coronary syndrome (ACS), guidelines recommend using high-sensitivity troponins (hs-cTn) in accelerated diagnostic pathways (ADPs) with 0/1-hour recommended over 0/3-hour ADP. However, implementation of these ADPs, with universal use of hs-cTns, has not been directly compared in randomized trials OBJECTIVES: This study sought to compare the efficiency and safety of the European Society of Cardiology (ESC) 0/1-hour and a 0/3-hour ADP when implemented in real-world clinical practice. METHODS: This pragmatic, randomized, noninferiority implementation trial compared the safety and efficiency of clinician decision making using these 2 pathways. To prevent incorporation bias, an independent hs-cTnI was used for formal adjudication using the fourth universal definition of myocardial infarction (MI). Efficiency was judged by the proportion of patients discharged within 4 hours. The safety endpoint was major adverse cardiac events (MACE) within 30 days (adjudicated index or representation type 1 MI, cardiovascular death, and urgent coronary revascularization) for those who were considered not to have ACS and discharged. The noninferiority margin, for absolute difference in sensitivity, between the ESC 0/1-hour and the 0/3-hour ADP was set at 3%, assessed with a 1-sided 97.5% CI. RESULTS: From December 2021 to July 2024, of 13,983 screened 3,543 individual patients with suspected ACS were recruited and consented from 2 major emergency departments in North-West England, with 100% follow-up achieved for all representations to any national hospital. The median age was 60 years (IQR: 49.5-70.5 years), 53% were men, 6.7%, and 7.6% had adjudicated index type 1 MI and MACE within 30 days, respectively. The turnaround time from sample to result for central laboratory hs-cTnT was 81 minutes (IQR: 69-101 minutes). The proportion of patients discharged within 4 hours was relatively low and did not differ substantially (21.8% vs 19.2%, P = 0.07). In addition, the 0/1-hour pathway was noninferior for safety, in patients discharged, compared with the 0/3-hour pathway, absolute difference in sensitivity was +4.2% (1-sided 97.5% CI: -2.5) in favor of the 0/1-hour pathway. The calculated sensitivities were 93.7% (95% CI: 88.4%-97.1%) vs 89.5% (95% CI: 82.7%-94.3%), respectively. CONCLUSIONS: Implementation of the ESC 0/1-hour pathway failed to discharge significantly more patients within 4 hours of presentation compared with the 0/3-hour ADP. In addition, The ESC 0/1-hour was noninferior to the 0/3-hour hs-cTn pathway for safety of discharge, although safety for both pathways was less than that imputed by observational studies. This trial demonstrates that perceived benefits to emergency department efficiency of a reduced sampling interval are mitigated by central laboratory turnaround times as well as system constraints. (Pragmatic Randomised Trial of the ESC 0/&#x200b;1 Versus 0/&#x200b;3 Hour Troponin Pathway [MACROS2]; NCT05322395).

Acute Coronary Syndrome

Improving survival in Duchenne muscular dystrophy across eras: a systematic review and cumulative meta-analysis.

BACKGROUND: Duchenne muscular dystrophy (DMD) was historically associated with death in the late teens or early twenties, mainly from respiratory failure. Survival has improved substantially with home mechanical ventilation (HMV) and multidisciplinary care, although variability remains. This study evaluated temporal trends in survival in DMD and the impact of HMV. METHODS: A study-level cumulative meta-analysis (PROSPERO CRD420251163011) of studies reporting survival outcomes in patients with DMD was conducted (PubMed 1977 to 13 October 2025). Pooled estimates of median survival were calculated, and random-effects meta-analyses with predefined subgroups (HMV and study period) were performed, alongside meta-regressions. Risk of bias was assessed using the Newcastle-Ottawa Scale. RESULTS: 53 studies (median follow-up 8&#xa0;years), comprising more than 13,000 patients, of whom 60% received HMV, were included. Median survival differed substantially between ventilated (29&#xa0;years, 95%CI 27 to 31) and non-ventilated (19&#xa0;years, 95%CI 18 to 20) patients. Survival improved progressively over time in both groups. Glucocorticoid therapy was not associated with improved survival (p=0.45), whereas treatment with heart failure medications, including renin-angiotensin system inhibitors (p=0.002) and &#x3b2;-blockers (p=0.02), was associated with longer survival. The predominance of mortality shifted from respiratory to cardiac causes, while enhanced cardiac management was associated with a growing contribution of other causes of death. CONCLUSION: Survival in DMD has increased substantially over time, with median survival now approaching the third decade of life among ventilated patients. The growing contribution of cardiac and other non-respiratory causes of death highlights the importance of long-term multidisciplinary and early cardioprotective intervention. STUDY REGISTRATION: The meta-analysis and systematic review have been registered on PROSPERO (CRD420251163011).

Humans

An automated geometric modeling framework in GATE for the design and optimization of high-sensitivity converging-beam SPECT collimators.

Objective.The trade-off between detection sensitivity and spatial resolution is a fundamental challenge in designing organ-dedicated Single-photon emission computed tomography (SPECT) collimators. While converging-hole geometries offer a solution, their optimization is often hindered by the lack of flexible computational tools capable of modeling large-scale, non-parallel hole arrays. This study aims to develop an automated geometric modeling framework to facilitate the design and evaluation of complex converging- and diverging-hole collimators within standard Monte Carlo environments.Approach.We developed a specialized modeling framework by implementing custom C++ classes and a vector-based alignment algorithm within GATE. This platform enables automated, orientation-consistent construction of large-scale converging arrays not natively supported by standard implementations. A high-sensitivity pure cone-beam collimator (CBC) was designed using this framework. The evaluation used hot-rod, disc, and Jaszczak phantoms for physical characterization, while XCAT and dedicated brain models were employed for clinical tasks, including cardiac, brain perfusion, and DaTscan SPECT simulations.Main results.The CBC achieved a nearly fourfold sensitivity increase compared to a conventional low-energy high-resolution parallel-hole collimator at a 20 cm radius of rotation, while maintaining comparable spatial resolution. Despite a 52.3% field of view reduction, the CBC yielded a 2.2-fold noise reduction (CV: 11.7% vs 25.9%) and mitigated partial volume effects via geometric magnification. XCAT and brain phantom simulations confirmed enhanced anatomical definition and contrast recovery in cardiac, perfusion, and DaTscan tasks.Significance.This work provides an efficient computational tool for rapid design space exploration of advanced collimator geometries. The results demonstrate that the proposed CBC design offers a significant sensitivity advantage, making it highly suitable for high-performance, small-volume clinical applications such as brain and cardiac molecular imaging.

Tomography, Emission-Computed, Single-Photon