Search PubMedSearch

SEARCH · Search PubMed

Results for “Psychomotor Performance”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

827 records · Page 7Linked to original sources

Is There a Difference in Occurrence of Complications Between Adults With Hemoglobin SS and Hemoglobin SC Disease: An Extended Systematic Review.

Sickle cell disease (SCD) is characterized by both acute and chronic complications. The clinical manifestation of these complications differs between genotypes. Given the large amount of research already published, this systematic review aims to offer a complete overview of types of sickle cell complications between adults in the most common genotypes Hemoglobin SS (HbSS) and Hemoglobin SC (HbSC), putting options for further research into perspective. An extensive literature search was performed to study all available evidence on these complications. This review was performed according to the "Preferred Reporting Items for Systematic Reviews and Meta-Analyses" (PRISMA) statement guidelines, and was performed on January 2, 2024. A total of 710 references were identified. After careful screening, 521 records were excluded based on title and abstract and other exclusion criteria. In total, 158 articles were excluded after full-text assessment. Our analysis of 31 studies highlights key differences in complications between HbSS and HbSC genotypes in sickle cell disease (SCD). Vaso-occlusive crises (VOCs) remain the most common acute complication in both genotypes. HbSS patients experience more frequent VOCs, while HbSC patients generally have a milder clinical course when it comes to acute complications. Chronic complications, particularly in the ocular and pulmonary systems, are more prevalent in HbSC patients. However, as acute complications are more common in HbSS and chronic complications more common in HbSC, both genotypes face progressive organ damage due to recurrent ischemic injury and inflammation.

Humans

Reliability-aware hierarchical learning for Chagas disease screening from 12-lead ECGs: tackling label uncertainty and class imbalance.

Objective.Chagas disease, a neglected tropical disease (NTD) with significant cardiovascular impact, remains underdiagnosed in resource-limited regions. Electrocardiogram (ECG) screening offers a low-cost tool for detecting cardiac involvement, yet algorithm development is challenged by label noise, data scarcity, and the latent nature of infection. This study proposes a robust ECG-based screening framework that explicitly addresses these constraints.Approach.We introduce aReliability-Aware Hierarchical Learningstrategy that calibrates supervision according to data provenance, prioritizing serology-confirmed labels over noisy self-reports. To mitigate data scarcity, we compare a specialized convolutional neural network (CNN) trained from scratch with a transfer learning approach based on a Spatio-Temporal ECG foundation Model (FM). Performance is evaluated across varying data scales, and the representation structure is analyzed to interpret model behavior.Main results.On the official hidden test set of the George B. Moody PhysioNet/Computing in Cardiology Challenge 2025, our approach achieved a Challenge Score of 0.163. We observe that while the specialized CNN performs competitively in data-rich regimes, the FM exhibits superior robustness in extreme low-resource settings. Furthermore, performance reaches a plateau imposed by underlying disease physiology. Bimodal score distributions suggest that models distinguish established cardiomyopathy from indeterminate infection, which remains electrophysiologically indistinguishable from healthy controls.Significance.These findings clarify both the potential and intrinsic limits of ECG-based AI screening for NTD-associated cardiac involvement. Reliability-aware supervision and data-efficient transfer learning provide a practical framework toward scalable and clinically meaningful ECG screening systems in resource-constrained environments.

Humans

Efficacy of the NMIC-150 system in identifying extended-spectrum beta-lactamases in clinical isolates.

Extended-spectrum beta-lactamases (ESBLs) are significant contributors to the growing global crisis of antimicrobial resistance. This study evaluated the performance of the NMIC-150 System for susceptibility testing of third-generation cephalosporins (3GCs) and assessed whether ceftazidime-avibactam and aztreonam-avibactam could identify ESBL-producing carbapenem-resistant Enterobacterales (CREs). A total of 278 non-duplicate clinical isolates (Klebsiella pneumoniae, E. coli, and Proteus mirabilis) were analyzed. Antimicrobial susceptibility was determined using reference broth microdilution (BMD) and the NMIC-150 System. ESBL production was defined as an ≥eight-fold reduction in the minimum inhibitory concentration (MIC) of 3GCs in the presence of clavulanic acid, according to CLSI criteria. Whole-genome sequencing was performed to characterize ESBL and carbapenemase genes among 3GC-resistant isolates. A Random Forest model was used to predict ESBL-producing isolates based on MIC values. The NMIC-150 System demonstrated over 90% categorical and essential agreement with BMD for ceftazidime and ceftriaxone, along with robust predictive performance via Random Forest analysis. These findings suggest that the NMIC-150 System is a reliable platform for 3GC susceptibility testing and that an ≥eight-fold MIC reduction with ceftazidime-avibactam or aztreonam-avibactam may serve as a phenotypic indicator of ESBL production in CRE isolates. In conclusion, the NMIC-150 System shows potential for routine antimicrobial resistance surveillance and may facilitate the rapid identification of ESBL-producing CREs in clinical settings.

Microbial Sensitivity Tests

A reanalysis of the Hitachi cohort study evaluating the effectiveness of low-dose CT screening for lung cancer.

The effectiveness of low-dose thoracic computed tomography (CT) screening for lung cancer for non-smokers or light smokers has been unclear. The results of the Hitachi cohort study performed by the conventional multivariable analysis suggested the reduction of lung cancer mortality by thoracic CT screening, but also revealed the lower all-cause mortality in the CT group, which indicated the existence of self-selection bias. Because the background of the subjects in the CT screening group and that in the X-ray screening group were very different, it is critical to adjust appropriately the confounding factors. In this brief report, we describe a re-evaluation of the results of the Hitachi Cohort Study performed by using more flexible methods, propensity score matching and inverse probability weighting.

epidemiology/public health

Automated CEAP Classification of Venous Duplex Reports Using Multimodal Artificial Intelligence.

OBJECTIVE: To develop and internally validate a prototype multimodal artificial intelligence system for automated CEAP (Clinical, Etiological, Anatomical and Pathophysiological) classification of venous duplex ultrasound (VDUS) reports, integrating natural language processing of free-text components with computer vision analysis of hand-drawn anatomical diagrams. METHODS: Single centre retrospective observational study using routinely collected clinical data. One thousand consecutive venous duplex ultrasound reports from Cambridge University Hospitals NHS Foundation Trust, UK (July 2024 - May 2025) were labelled according to the CEAP classification, excluding the Etiological component, which could not be reliably determined from duplex reports alone. Transfer learning was applied using ClinicalBERT for text and MobileNetV3 for diagrammatic data. Clinical classes were predicted from request line text. Text- and image-based pathophysiological models were developed for four anatomical territories (Great Saphenous Vein, Small Saphenous Vein, Deep system, Perforators), combined using late fusion with probability averaging. RESULTS: The clinical CEAP model achieved accuracy of 0.91, macro-F1 of 0.82, and macro-AUC of 0.98. Pathophysiological prediction varied, with text models broadly outperforming image models. Fusion yielded heterogeneous benefits, improving SSV performance but reducing Deep system accuracy. The performance of the final pathophysiological CEAP fusion models varied across anatomical territories: accuracy ranged from 0.70-0.92 and macro-AUC from 0.80-0.92. CONCLUSION: This study demonstrates the feasibility of automated CEAP classification from VDUS reports. Despite class imbalance affecting minority class predictions, the strong discriminatory performance validates this multimodal ML model for extracting clinically meaningful information from real-world data. This approach offers potential, pending external validation, to streamline vascular services through automated triage and guideline-compliant decision making.

Artificial intelligence

Enhanced fracture detection on radiographs with AI assistance for clinicians: a systematic review and meta-analysis.

BACKGROUND: Emergency radiographic interpretation for fractures is prone to missed or misdiagnoses. Artificial intelligence (AI) is expected to become a powerful tool to assist clinicians in fracture detection. PURPOSE: A systematic review and meta-analysis was performed to assess whether AI improves clinicians' ability to detect fractures on radiographs. MATERIALS AND METHODS: A literature search was conducted in PubMed, Web of Science, and Cochrane Library for studies published between January 1, 2010, and October 10, 2025. A meta-analysis of diagnostic accuracy studies was performed using a Summary Receiver Operating Characteristic (SROC) curve. The quality of included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Subgroup analysis and meta-regression were conducted to explore potential sources of heterogeneity. RESULTS: A total of 26 studies were included . The pooled sensitivity of clinicians increased from 77% (95% CI: 72-81) to 87% (95% CI: 83-90) with AI assistance, while the pooled specificity improved from 88% (95% CI: 85-90) to 92% (95% CI: 89-94). The corresponding AUC values were 0.90 (95% CI: 0.87-0.92) before and 0.95 (95% CI: 0.93-0.97) after AI assistance. Eight studies were rated as high risk of bias. Subgroup analysis and meta-regression identified potential sources of heterogeneity, including fracture location, AI model type, high risk of bias, and reference standards. CONCLUSION: AI assistance significantly improves clinicians' diagnostic performance in detecting fractures on radiographs for extremity and trunk fractures.

Humans

The effect of olfactory training and odor exposure on visual selective attention.

Olfactory training (OT) is a well-established, non-invasive intervention that improves olfactory function by repeated, structured exposure to odorants. Beyond sensory outcomes, it also influences multiple aspects of cognition. Yet, its influence on attention, a fundamental process underlying many cognitive domains, remains unclear. This study examined the impact of a 12-week OT program on visual selective attentional performance and the effect of on-task odor exposure. Ninety-four healthy participants were initially included, and randomized into OT or placebo groups. Participants completed the d2 Test of Attention simultaneously with and without odor exposure in a randomized sequence at baseline, post-training, and a follow-up four weeks after stopping the training. The d2 test measures commission errors, omission errors, and concentration performance. Ninety-three participants (OT=51, placebo=42) completed baseline measurement, 74 (OT=39, placebo=35) returned for post-training session, and 57 participants (OT=29, placebo=28) returned for the follow-up appointment. Results showed that OT did not significantly improve d2 test performance. In the primary model, on-task PEA exposure reduced commission errors compared to the odorless condition, suggesting a possible transient effect of olfactory input on the inhibitory control in the context of the d2 attentional test. This effect, however, was no longer significant once the follow-up data were included and should be regarded as preliminary. Overall, these findings raise the possibility of a distinction between relatively long-term OT and short-term odor exposure: while OT did not improve visual selective attention, brief on-task odor exposure may transiently enhance inhibitory control during attentional tasks, a possibility that remains to be confirmed.

Humans

Response-optimised training improves learning of a complex motor task and closely related motor tasks.

Regular physical exercise is essential for promoting healthy aging and longevity. In older adults with varying physical and cognitive decline, optimising exercise interventions is crucial to maximise benefits. A promising approach to achieve this goal is by adjusting task demands to individual abilities in turn preventing over- or underloading their abilities. In the field of motor learning, it is currently unclear whether such an optimised training improves not only performance on the trained task but also transfers to untrained motor and cognitive tasks. We conducted a randomized, single-blinded, 6-week dynamic balance training (DBT) with healthy older adults (n = 30). Training was tailored to individual balance ability. Participants were assigned to either suboptimal (high or low difficulty) or optimal (moderate difficulty) training groups. Transfer effects were assessed via cognitive tasks (memory and executive) and motor tasks (untrained DBT variations and other balance tasks) measured pre-, mid- and post-intervention. Multivariate longitudinal statistical analysis showed higher performance gains in the optimal training group in three out of six sessions compared to the suboptimal groups, especially under testing conditions with high task demands. The optimal group also showed greater improvements in near motor transfer tasks mid- and post-intervention, while no significant differences were observed in the cognitive tasks. Within-group DBT learning positively correlated with transfer gains, highlighting the role of training response in achieving transfer. In conclusion, optimised task difficulty in balance training enhances both task-specific performance and related motor skills, supporting the use of personalised interventions to maintain function and independence in older adults.

Humans

Could creatine supplementation combined with physical rehabilitation accelerate return to play in athletes with patellar tendinopathy?

BACKGROUND: Several dietary supplements have been proposed to positively influence the rehabilitation process following injury. However, to date, no studies have specifically examined the effects of scientifically supported ergogenic aids on recovery outcomes when combined with physical performance interventions. Therefore, the aim of this study was to analyze the ergogenic effects of creatine supplementation on neuromuscular performance, tendon thickness, pain, and body composition in athletes diagnosed with patellar tendinopathy (PT). METHODS: Using a triple-blind experimental design, 20 federated athletes (age: 33.7&#x2009;&#xb1;&#x2009;9.84 years) with PT were randomly assigned to either a creatine supplementation group (CR; n&#x2009;=&#x2009;9) or a placebo group (PLA; n&#x2009;=&#x2009;11). All participants followed a physical rehabilitation intervention that included daily eccentric training combined with stretching exercises, along with one session every 10 days of extracorporeal shock wave therapy (ESWT) and manual therapy targeting the tendon and surrounding muscle tissue. At the end of each eccentric training session, the participants ingested 3 capsules of creatine monohydrate - Creapure&#xae; (CR) or sucrose (PLA). At the beginning (PRE), after 4 weeks (MID), and after 8 weeks (POST), the pain level (Victorian Institute for Sports Assessment-Patella, VISA-P), tendon thickness (echography), body composition (bioelectrical impedance system), and neuromuscular performance using a countermovement jump test (CMJ) and a strength test (5-RM) of knee extension in the injured leg. RESULTS: A significant main effect of time was observed for VISA-P scores (p&#x2009;<&#x2009;0.001; &#x3b7;2 p&#x2009;=&#x2009;0.626), indicating a reduction in pain over time in both the creatine (CR) and placebo (PLA) groups. At POST, both groups showed significant improvements compared to PRE (CR: 78.0 points [69.2-86.8] vs. 60.6 points [53.4-67.7]; p&#x2009;=&#x2009;0.002; PLA: 75.2 points [66.3-84.0] vs. 60.0 points [52.5-67.5]; p&#x2009;=&#x2009;0.003). However, only the CR group showed a statistically significant improvement in the MID compared to PRE (MID: 70.2 points [60.0-80.5]; p&#x2009;=&#x2009;0.027). A significant main effect of time was observed for both tendon thickness (p&#x2009;<&#x2009;0.001; &#x3b7;2 p&#x2009;=&#x2009;0.629) and the 5-RM leg extension test (p&#x2009;<&#x2009;0.001; &#x3b7;2 p&#x2009;=&#x2009;0.739), with both groups showing progressive improvements over time. Nevertheless, as trend toward a statistically significant time&#xb7;supplementation interaction was observed (p&#x2009;=&#x2009;0.099; &#x3b7;2p&#x2009;=&#x2009;0.126), with an increase in performance only in CMJ in MID vs PRE (36.8&#x2009; cm (33.8-39.7) vs 34.3&#x2009; cm (30.8-37.7); p&#x2009;=&#x2009;0.019) and POST vs MID (POST: 37.6&#x2009; cm (33.5-41.8); p&#x2009;=&#x2009;0.015). CONCLUSIONS: A physical rehabilitation program involving eccentric training, stretching, and ESWT is effective in reducing tendon thickness and increasing muscle strength. However. It seems that the addition of CR induces an earlier reduction of pain and a positive effect on CMJ performance. Therefore, CR could be considered as an ergogenic recovery aid in athletes with PT.

Humans

Axial Length Adjustment and AL/R Ratio Optimization of IOL Power Calculation in Extremely Long Eyes.

PURPOSE: To evaluate the accuracy of modern intraocular lens (IOL) power calculation formulas and axial length (AL) adjustment methods in eyes with AL &#x2265; 30.0 mm. DESIGN: Retrospective consecutive cross-sectional study. PARTICIPANTS AND CONTROLS: A total of 308 eyes (308 patients) with AL &#x2265; 30.00 mm were included. METHODS: Accuracy of modern online formulas, alone or with established AL adjustments methods, was analyzed. Subgroup analyses were performed based on AL, keratometry (K), anterior chamber depth (ACD), lens thickness (LT), and AL-to-corneal radius (AL/R) ratio. MAIN OUTCOME MEASURES: Predictive accuracy was evaluated using the formula performance index (FPI), root mean square absolute prediction error (RMSAE), standard deviation (SD) of prediction error (PE), and percentage of eyes within &#xb1;0.25 and &#xb1;0.50 diopters (D). RESULTS: Overall, Holladay 1 combined with the nonlinear polynomial Wang-Koch axial length adjustment (H1-PWK) demonstrated the best overall performance, achieving the lowest SD (0.40), RMSAE (0.40), and highest FPI (0.494). A tendency toward hyperopic error was observed in eyes with AL &#x2265; 32.0 mm, K &#x2265; 46.0 D. The AL/R ratio showed a significant positive correlation with PE in the Ladas Super formula, Barrett Universal II, EVO, PEARL-DGS, and Hoffer QST formulas. Spline-based regression analysis indicated that the transition point of AL/R from myopic to hyperopic PE varied across different formulas. CONCLUSIONS: H1-PWK provides robust refractive accuracy in extremely long eyes. The AL/R ratio may provide a useful composite biometric stratification parameter compared to AL alone.

Humans

The Role of Artificial Intelligence Combined With Digital Cholangioscopy for Indeterminant and Malignant Biliary Strictures: A Systematic Review and Meta-analysis.

BACKGROUND: Current endoscopic retrograde cholangiopancreatography (ERCP) and cholangioscopic-based diagnostic sampling for indeterminant biliary strictures remain suboptimal. Artificial intelligence (AI)-based algorithms by means of computer vision in machine learning have been applied to cholangioscopy in an effort to improve diagnostic yield. The aim of this study was to perform a systematic review and meta-analysis to evaluate the diagnostic performance of AI-based diagnostic performance of AI-associated cholangioscopic diagnosis of indeterminant or malignant biliary strictures. METHODS: Individualized searches were developed in accordance with PRISMA and MOOSE guidelines, and meta-analysis according to Cochrane Diagnostic Test Accuracy working group methodology. A bivariate model was used to compute pooled sensitivity and specificity, likelihood ratio, diagnostic odds ratio, and summary receiver operating characteristics curve (SROC). RESULTS: Five studies (n=675 lesions; a total of 2,685,674 cholangioscopic images) were included. All but one study analyzed a deep learning AI-based system using a convoluted neural network (CNN) with an average image processing speed of 30 to 60 frames per second. The pooled sensitivity and specificity were 95% (95% CI: 85-98) and 88% (95% CI: 76-94), with a diagnostic accuracy (SROC) of 97% (95% CI: 95-98). Sensitivity analysis of CNN studies (4 studies, 538 patients) demonstrated a pooled sensitivity, specificity, and accuracy (SROC) of 95% (95% CI: 82-99), 88% (95% CI: 72-95), and 97% (95% CI: 95-98), respectively. CONCLUSIONS: Artificial intelligence-based machine learning of cholangioscopy images appears to be a promising modality for the diagnosis of indeterminant and malignant biliary strictures.

Humans

Cisplatin-Induced Hearing Loss Prevention With Intratympanic Therapy Systematic Review and Meta-Analysis.

INTRODUCTION: Cisplatin-induced hearing loss (CIHL) is a well-described, long-term consequence of cisplatin treatment for malignancy. Intratympanic (IT) injections have been trialed to prevent CIHL in humans. To provide clarity on which agents have been studied through IT injection and to review their efficacy for hearing loss prevention, we performed a systematic review and meta-analysis. DATA SOURCES: OVID Medline, Embase, Web of Science, and Cochrane Library were queried. METHODS: Databases were searched in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. Prospective randomized trials were included, and a systematic review was performed for all studies. Demographic, audiometric, and therapeutic data were collected. Random-effects models were used to compare across studies, and subgroup analyses were performed for each IT agent. RESULTS: The initial database search yielded 1017 articles, which were screened according to inclusion and exclusion criteria. Ten studies were identified, involving a total of 284 patients. Studies included data on IT dexamethasone, IT N-acetylcysteine (NAC), and IT sodium thiosulfate (STS). Pooled analysis across all agents and frequencies did not reveal a significant difference in hearing thresholds between treatment and control ears [prediction interval [-3.77, 3.20], negative favors treatment). Subgroup analysis of IT dexamethasone [-1.74, 3.80] and IT NAC [-1.02, 4.64] also did not demonstrate significant differences. STS data were not amenable to pooled analysis; however, one study demonstrated a significant decrease in ASHA-defined ototoxicity (40% vs. 85%, P =0.0027). CONCLUSIONS: To date, no IT agent has consistently prevented CIHL, although limited data suggest that IT STS may decrease ototoxicity. More trials are necessary to fully elucidate these effects.

Humans

Assessment of atypical glandular cell interpretation in Pap tests using the Hologic Genius Digital Diagnostics System.

Atypical glandular cells (AGC) are a diagnostic challenge. The aim of this study was to evaluate the efficacy and diagnostic performance of AGC detection on the Hologic Genius Digital Diagnostics System (HGDDS). A retrospective analysis of 451 ThinPrep Pap cases was conducted, including 207 cases of AGC, 27 cases of high-grade squamous intraepithelial lesion (HSIL), 25 cases of low-grade squamous intraepithelial lesion (LSIL), and 192 benign cases. All AGC cases had follow-up histologic diagnoses, with 66 cases subsequently diagnosed as adenocarcinoma. The slides were randomized, scanned, and analyzed by the HGDDS. Patient age and HPV test results were provided to reviewers, an experienced cytologist, who screened the cases, followed by two cytopathologists who independently examined the cases on the HGDDS. Diagnostic concordance between the two cytopathologists indicated strong agreement (&#x3ba; = 0.829). Sensitivity of AGC on Papanicolaou (Pap) tests for adenocarcinoma detection on HGDDS was 98.5% and 95.5%, respectively, comparable to the original ThinPrep interpretation (OTPI). Specificity for adenocarcinoma detection was significantly higher (84.6% and 85.6%) with the HGDDS than 27.7% with OTPI. Overall, the diagnostic performance for AGC/HSIL interpretation to detect CIN2/3/adenocarcinoma appeared to have improved with HGDDS compared with OTPI, particularly for specificity and positive predictive value (PPV). This is the first study evaluating AGC diagnosis using the HGDDS. The findings demonstrate that the sensitivity of adenocarcinoma detection as AGC on HGDDS is comparable to the ThinPrep Imaging System, but the specificity and PPV are improved. This suggests the potential of artificial intelligence to augment the performance of cervical cancer screening.

Humans

A randomized study of antibiotic prophylaxis after hypospadias repair in children.

BACKGROUND AND OBJECTIVE: Antibiotic resistance is a challenge in contemporary world. Urethroplasty for hypospadias is one of the most common urological surgeries performed around the world, yet, there is still no consensus on the use of antibiotics pre- and post-operatively. Our objective was to analyze the effectiveness of antibiotic prophylaxis and therapy before, during, and after hypospadias repair in children. METHODS: A prospective randomized trial was carried out including patients with coronal hypospadias who underwent urethroplasty performed by one surgeon. Urethral catheters were used in all cases for 10 days. Study participants were randomly assigned in a 1:1:1 ratio to receive a single intraoperative administration of antibiotics (Group I); an intraoperative antibiotic prophylaxis and antibiotic therapy for 10 days until the removal of urethral catheter (Group II); no antibiotic administration (Group III). Randomization was performed using computer-generated permuted blocks with randomly varying block sizes, prepared by an independent statistician. The results were analyzed using the analysis of variance (ANOVA). The following criteria were compared: postoperative functional complications, such as: urethral fistula, stenosis, diverticulum; wound infection symptoms: hyperemia of surgical site, pain during palpation, and symptomatic urinary tract infection. RESULTS: A total of 300 patients were included in the study. Two patients (2%) in Group I, two patients (2%) in Group II, and four patients (4%) in Group III had urethral fistulas, requiring surgery 6 months after primary repair, yet without statistical difference between groups. We found no significant difference in frequency of symptomatic UTIs between three groups (p = 0.182). CONCLUSION: There is no effect of antibiotic prophylaxis and therapy on the frequency of postoperative surgical and infectious complications after urethroplasty for coronal hypospadias repair in children.

Humans

Comparative effects of 12-week resistance training on unstable and stable surfaces on muscle stiffness, muscle co-activation, and balance in older patients with knee osteoarthritis.

OBJECTIVE: This randomized trial compared the effects of unstable resistance training (URT), involving resistance exercises on unstable surfaces, and stable resistance training (SRT), performed on stable surfaces, on muscle stiffness, co-activation, and balance in older adults with knee osteoarthritis (KOA). We hypothesized that URT would yield greater improvements by enhancing neuromuscular adaptability. METHODS: Fifty patients with KOA were randomly assigned to the URT group (n&#x202f;=&#x202f;25) or the SRT group (n&#x202f;=&#x202f;25). After attrition, 46 participants (URT: n&#x202f;=&#x202f;23; SRT: n&#x202f;=&#x202f;23) completed the intervention and were included in the final analysis. Both groups completed a 12-week supervised lower-limb resistance training program (3 sessions/week) consisting of 10 exercises performed under either unstable or stable support conditions. RESULTS: After 12 weeks of intervention, both groups showed significant reductions in pain intensity (p&#x202f;<&#x202f;0.001). However, compared with the SRT group, the URT group demonstrated significantly greater reductions in quadriceps stiffness (p&#x202f;<&#x202f;0.05), selected hamstring stiffness outcomes (p&#x202f;<&#x202f;0.05), and quadriceps-hamstring co-activation (p&#x202f;<&#x202f;0.001), alongside superior improvements in both dynamic balance and static balance (all p&#x202f;<&#x202f;0.05). CONCLUSION: While both training modalities are effective for pain relief, URT elicited greater improvements in balance-related performance and neuromuscular-mechanical outcomes than SRT in older adults with KOA. These findings suggest that incorporating unstable support conditions into resistance training may provide additional rehabilitation benefits for this population.

Humans

RR-interval-based atrial fibrillation detection and burden estimation: cross-dataset validation and calibration-aware probability analysis.

Objective.Atrial fibrillation (AF) burden has become an increasingly important endpoint in long-duration rhythm monitoring, but reliable burden estimation requires more than accurate AF detection alone. In particular, when burden is derived by aggregating predicted AF probabilities over time, probability calibration may directly affect burden validity under external dataset shift.Approach.This study developed an interpretable-interval feature model for AF detection and evaluated it using record-wise cross-validation on a development cohort and independent cross-dataset external validation on public Holter electrocardiographic databases. Window-level performance was assessed using the area under the receiver operating characteristic curve (ROC-AUC), area under the precision-recall curve (PR-AUC), Brier score, expected calibration error (ECE), and calibration intercept and calibration slope. Recording-level AF burden was estimated using both probability-based and hard-label aggregation and evaluated using mean absolute error (MAE) and agreement analyses.Main results.The model showed high discrimination in both development and external evaluation, with external ROC-AUC ofand PR-AUC of. However, external calibration deteriorated despite preserved ranking performance, with Brier score of, ECE(15) of, calibration intercept of, and calibration slope of. In the external cohort, probability-based burden estimation preserved strong association with reference burden but showed weaker raw agreement than hard-label aggregation, with MAE ofversus, consistent with systematic probability underprediction. Repeated external recalibration across record-level splits substantially improved probability quality and probability-based burden estimation. Median probability-burden MAE decreased fromwithout recalibration toafter Platt recalibration andafter isotonic recalibration, while median ECE(15) decreased fromtoand, respectively.Significance.These findings indicate that-interval-based AF detection maintained strong ranking performance in the tested external cohort, but probability calibration should be evaluated explicitly when predicted probabilities are aggregated into AF-burden estimates.

Atrial Fibrillation

Endoscopic submucosal dissection for locally recurrent gastric neoplasia following endoscopic resection: a systematic review and meta-analysis.

BACKGROUND AND AIMS: Endoscopic submucosal dissection (ESD) for locally recurrent gastric neoplasia following endoscopic resection (ER) is technically challenging because of scar-related submucosal fibrosis. We performed a systematic review and meta-analysis to evaluate the efficacy and safety of salvage ESD in this setting. METHODS: Multiple databases were searched through December 2025 for studies reporting ESD outcomes for locally recurrent gastric lesions at or contiguous with a prior ER scar. Primary outcome was curative resection and need for surgery. Secondary outcomes were en bloc and R0 resection, local recurrence, delayed bleeding, and perforation. Meta-analyses were performed using a random effects model. Heterogeneity was assessed using I2. RESULTS: Seven studies (259 patients; 265 ESDs) were included. Across 5 studies and 243 ESDs, pooled curative resection rate was 69.7% (95% CI, 60.6-78.1; I2 = 38%), while 8.2% (95% CI, 3.3-14.6; I2 = 38.4%) required surgery. En bloc resection rate was 92.3% (95% CI, 79.1-99.7; I2 = 83.7%) across 6 studies, and pooled R0 resection rate was 87.5% (95% CI, 82.1-92.2; I2 = 0%) across 4 studies. Over a mean follow-up of 42 months, pooled local recurrence was 2.0% (95% CI, 0.0-9.7; I2 = 54.1%) across 6 studies. Delayed bleeding was 4.1% (95% CI, 0.8-9.0; I2 = 40.8%) and perforation was 4.1% (95% CI, 1.6-7.3; I2 = 0%). CONCLUSIONS: ESD for locally recurrent gastric neoplasia after ER achieves acceptable curative resection, high en bloc/R0 resection, and low local recurrence and morbidity. It is a viable organ-preserving option for appropriately selected patients, ideally performed at expert centers with close surveillance.

Humans

Urinary Small Extracellular Vesicle DNA as a Biomarker for the Non-Invasive Diagnosis of Bladder Cancer.

Existing diagnostic technologies for bladder cancer (BC) suffer from low sensitivity, low specificity, or a lack of validation. Therefore, validated, non-invasive diagnostic biomarkers with high sensitivity and specificity for early detection of BC are needed to complement and improve upon the limitations of existing diagnostic methods. We used low-pass whole genome sequencing (LP-WGS) technology to detect copy number variations (CNVs) in small extracellular vesicle (sEV) DNA isolated from urine samples of patients. Based on these results, we constructed and validated a diagnostic model to differentiate between benign and malignant bladder lesions. We conducted a receiver operating characteristic analysis and calculated the area under the curve (AUC) to evaluate the performance of the diagnostic model. The urine sEV-DNA LP-WGS data revealed CNV differences between benign and malignant samples. The diagnostic model achieved an AUC of 0.953, a sensitivity of 86.7%, and a specificity of 100% in the training cohort and an AUC of 0.985, a sensitivity of 90%, and a specificity of 100% in the validation cohort. Even at the lowest coverage depth of 0.01X, the performance of the diagnostic model remained relatively robust. Notably, the performance of this diagnostic model surpassed that of the biomarker neuron-specific enolase (sensitivity: 85.7% vs. 64.3%; specificity: 100% vs. 87.5%) and urinary cytology (sensitivity: 100% vs. 66.7%; specificity: 100% vs. 94.1%). Our study demonstrates that urine sEV-DNA exhibits high discriminatory power in distinguishing between benign and malignant bladder lesions, making it a promising tool for auxiliary diagnosis of BC.

Humans