Search PubMedSearch

SEARCH · Search PubMed

Results for “Magnetic Resonance Imaging”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

252 records · Page 7Linked to original sources

Shielding performance and clinical applicability of lead-free materials in computed tomography.

Owing to the high radiation exposure associated with computed tomography (CT) examinations and the image quality degradation caused by conventional radiation shielding materials, this study evaluated the dose reduction performance and image quality maintenance potential of a newly developed lead-free composite shielding material. This material was composed of bismuth, tungsten, tungsten carbide, aluminium, and polyurethane. Phantom-based dose measurements demonstrated that the shielding material achieved dose reduction rates ranging from 17.6% to 37.6%, depending on tube voltage. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and changes in tube current-time product (mAs) under a scout-based automatic exposure control (AEC) protocol were analysed according to the presence or absence of the shielding material across regions. For the clinical evaluation, CT scans were performed on four patients. Furthermore, the images were reviewed to evaluate whether this material affected image quality. The shielding material exhibited radiation reduction levels comparable to those reported in previous studies. SNR and CNR analyses showed minor statistical variations in certain regions; however, most differences were not statistically significant, and even significant differences remained within a range that did not compromise diagnostic image quality. Under the scout-based AEC protocol, the use of the shielding material resulted in less than 1% variation in mAs values. No visually perceptible artefacts or clinically significant image quality degradation were observed. The proposed composite shielding material demonstrated the potential to mitigate some limitations of conventional shielding materials and showed preliminary clinical feasibility as an adjunctive strategy for radiation dose reduction in CT examinations.

Radiation Protection

Linked-color imaging with computer-aided detection and the proximal adenoma miss rate: a randomized tandem trial.

BACKGROUND AND AIMS: Linked-color imaging (LCI) aids the detection and characterization of lesions. Computer-aided detection (CADe) systems have been introduced to improve lesion detection during colonoscopy. Although several studies have been reported regarding LCI, few have investigated the combination of LCI and CADe. This study aimed to evaluate the efficacy of LCI with CADe colonoscopy compared to conventional white-light colonoscopy. METHODS: A single-center, randomized tandem trial was conducted. Participants referred for first-time colonoscopy after fecal immunochemical test (FIT)-positive, asymptomatic screening, or surveillance colonoscopy were randomized (1:1) to undergo CADe-assisted colonoscopy of LCI or white-light imaging (WLI) in the right side of the colon. The primary outcome was adenoma miss rate (AMR) in the right side of the colon. Secondary outcomes included polyp miss rate (PMR), diminutive adenoma miss rate (dAMR), sessile serrated lesion miss rate (SSLMR), advanced adenoma miss rate, advanced neoplasia miss rate, flat-type lesion miss rate (FMR), and the differences in miss rates based on expertise. RESULTS: Among 232 randomized participants, 209 were analyzed (LCI/CADe: 102; WLI: 107). AMR (WLI: 39% vs LCI/CADe: 20%; P = .001), PMR (42% vs 18%; P < .001), and dAMR (42% vs 21%; P = .003) were significantly lower in the LCI/CADe arm, particularly among experts. SSLMR (46% vs 0%), advanced AMR (30% vs 0%), advanced neoplasia miss rate (25% vs 0%), and FMR (27% vs 5.6%) were lower in LCI/CADe, although without statistical significance. CONCLUSIONS: Compared to conventional colonoscopy, LCI with CADe colonoscopy resulted in a statistically significant decrease, especially in AMR. (UMIN 000050685).

Humans

An RPA-assisted homogeneous electrochemical DNA sensor for on-site eDNA detection toward early warning of crown-of-thorns starfish outbreaks.

Crown-of-thorns starfish (COTS) outbreaks seriously threaten coral reef ecosystems, while conventional monitoring approaches are time-consuming and often lack sufficient sensitivity for early warning. Existing electrochemical DNA sensors usually require complex electrode-surface immobilization procedures, which can lead to uneven probe distribution, significant steric hindrance, and poor stability. Meanwhile, the low concentration of environmental DNA (eDNA) in marine environments further complicates detection. To overcome these challenges, this study developed a homogeneous electrochemical DNA sensor assisted by recombinase polymerase amplification (RPA) for COTS eDNA detection. Target DNA was first amplified by RPA, and the amplification products were then hybridized in solution with capture probe (CP)-modified magnetic beads (MB) and biotin-labeled signal probe (SP) to form sandwich-structured MB complexes. These complexes were subsequently magnetically enriched and immobilized on the electrode surface for electrochemical signal readout. Under optimized conditions, the sensor displayed a linear response to COTS genomic DNA from 3.77&#xa0;fg/&#x3bc;L to 1&#xa0;ng/&#x3bc;L, with an LOD of 2.02&#xa0;fg/&#x3bc;L and an LOQ of 3.77&#xa0;fg/&#x3bc;L. The sensor was applied to Xisha Islands samples, and the results agreed with droplet digital PCR (ddPCR) (P&#xa0;>&#xa0;0.05), demonstrating its potential for sensitive and reliable on-site COTS eDNA detection.

Animals

Ketamine Plus Midazolam versus Fentanyl Plus Midazolam for Sedation and Analgesia during Image-guided Procedures in Interventional Radiology: Randomized Clinical Trial.

Background Opioid-benzodiazepine regimens remain common for radiologist-administered procedural sedation despite respiratory and analgesic effectiveness concerns. Purpose To compare intraprocedural pain and patient-reported experience between ketamine/midazolam and fentanyl/midazolam during image-guided procedural sedation. Materials and Methods This randomized clinical trial was conducted at a single academic center between June 2025 and February 2026. Adults undergoing image-guided lung or bone biopsy or abscess drainage were randomized to fentanyl/midazolam or ketamine/midazolam administered by interventional radiologists. Procedures were performed using US, CT, CT fluoroscopy, or combined CT and US guidance. The primary outcome was maximum intraprocedural pain (0-10 on the Numeric Rating Scale). Secondary outcomes included sedation depth, physiologic parameters, oxygen desaturation, patient-reported experience assessed using a modified Heidelberg questionnaire, and complications. Results Among 264 randomized procedures (132 procedures per group) in 260 participants (median age, 68 years [IQR, 61-75 years]; 135 [52%] female), ketamine/midazolam resulted in lower maximum intraprocedural pain than fentanyl/midazolam (mean difference, -1.4 points [95% CI: -2.0, -0.8]; P < .001). Pain scores greater than 4 occurred less frequently with ketamine/midazolam (2.3% vs 17%; absolute difference, 14 percentage points [95% CI: 8, 21]; P < .001). Ketamine/midazolam was associated with higher nadir oxygen saturation (mean difference, +1.4% [95% CI: 0.6, 2.2]; P = .001) and fewer oxygen desaturation events below 90% (three [2.3%] vs 13 [9.8%]; absolute difference, 7.6 percentage points [95% CI: 1.9, 13.3]; P = .02). Ketamine/midazolam produced deeper sedation and higher intraprocedural systolic blood pressure. Hallucinations occurred more frequently with ketamine/midazolam (15 [11.4%] vs five [3.8%]; absolute difference, 7.6 percentage points [95% CI: 1.3, 13.9]; P = .03), though overall procedural comfort, reduced recall, and perceived adequacy of sedation were improved. Procedure-related and sedation-related complications did not differ between groups. Conclusion Radiologist-administered ketamine/midazolam during image-guided procedural sedation improved analgesia and patient-reported experience with fewer hypoxemic events and no increase in complications compared with fentanyl/midazolam. Clinical trial registration no. NCT07040163

Aged

Gender-specific pathways linking body dissatisfaction, self-disgust, and social anxiety in Chinese adolescents: A three-wave longitudinal study.

Adolescence is a critical period for physical and psychological development. Body dissatisfaction is a significant concern during this stage, contributing to psychological issues such as social anxiety. However, the longitudinal relationships among body dissatisfaction, self-disgust, and social anxiety, as well as the potential role of gender differences in these dynamics, remain unclear. A total of 1109 junior high school students in China completed the baseline survey, with data collected at three time points (Mage = 12.67 years, SD&#x202f;=&#x202f;0.68; 51.9% girls). Data were collected using the Body Areas Satisfaction Scale (BASS), the Self-Disgust Scale (SDS), and the Social Anxiety Scale for Children (SASC). Structural equation modeling (SEM) was employed to examine the longitudinal mediating effects among body dissatisfaction, self-disgust, and social anxiety, as well as to explore gender differences in these relationships. After controlling for autoregressive effects of self-disgust and social anxiety across waves, body dissatisfaction at T1 was found to indirectly predict social anxiety at T3 through self-disgust at T2, while indirectly predicting self-disgust at T3 through social anxiety at T2. Multi-group analyses revealed significant gender differences: for females, only the mediating pathway with self-disgust as the mediator was significant; for males, only the pathway with social anxiety as the mediator was significant. These findings contribute to a more nuanced understanding of the emotional mechanisms linking body dissatisfaction to social anxiety and highlight the importance of considering gender-specific pathways in prevention and intervention efforts.

Adolescent

Comparison of Iodinated Contrast Doses Based on Total Body Weight and Lean Body Weight in Pediatric Patients: Impact on Image Quality and Contrast Exposure.

INTRODUCTION: Iodinated contrast dosing in pediatric computed tomography (CT) traditionally relies on total body weight (TBW), which may result in excessive contrast administration, particularly in patients with higher adiposity. Lean body weight (LBW)-based protocols have shown promise in adults but remain underexplored in children. Therefore, the aim of this study was to compare contrast volume requirements and hepatic enhancement quality among three dosing protocols: LBW-based, TBW-based, and the Control Group (CG), based on the institutional standard for pediatric abdominal CT. METHODS: This prospective study enrolled 66 patients (age 0-16 years) undergoing contrast-enhanced abdominal CT between September 2023 and August 2024. Patients were randomly assigned to receive iodinated contrast (iobitridol 350mg I/mL) dosed by: (1) LBW (0.63 g iodine/kg x LBW, calculated using Peters formula; n = 23), (2) TBW (0.46 g iodine/kg x TBW; n = 20), or (3) institutional control protocol (2 mL/kg x TBW, equivalent to 0.7 g iodine/kg; n = 23). Kruskal-Wallis, ANOVA, Two-way ANOVA, ANCOVA, Scheirer-Ray-Hare, and Cohen's Kappa tests with Likert scale were used. RESULTS: The LBW group received lower median contrast volumes (27 mL; IQR, 10-80 mL) compared to the TBW group (34.5 mL; IQR, 18-78 mL) and the CG group (40 mL; IQR, 13-80 mL), although the differences did not reach statistical significance (P > 0.05). Notably, this reduction did not compromise hepatic enhancement, which remained comparable to the CG (552 &#xb1; 139 HU; P = 0.107). CONCLUSION: Lean body weight may be a useful parameter for estimating contrast dose in pediatric abdominal CT, potentially reducing administered volumes without compromising diagnostic image quality. IMPLICATIONS FOR PRACTICE: These results provide early evidence that LBW-based dosing may support more individualized contrast administration in pediatric CT, potentially reducing exposure-related risks.

Humans

Liquid biopsy-based detection of circulating and exfoliated cholangiocarcinoma tumor cells from blood and bile using heparan sulfate octasaccharides on integrated microfluidic systems.

Early diagnosis of cholangiocarcinoma (CCA) remains challenging because existing diagnostic approaches often lack sufficient sensitivity for reliable detection of early-stage disease. Circulating tumor cells (CTCs) in blood and exfoliated tumor cells (ETCs) in bile represent valuable targets for liquid biopsy-based detection; however, their low abundance and the complexity of clinical sample analysis pose substantial technical challenges for reliable enrichment and identification. Herein, we present a reproducible workflow for isolating and identifying CCA tumor cells from blood for CTCs and bile for ETCs using synthetic cell-surface heparan sulfate (HS) octasaccharide-functionalized magnetic beads (MBs) on integrated microfluidic systems. The method combined sample pre-processing, magnetic bead-based enrichment, controlled low-shear mixing and immunofluorescence-based identification into a unified workflow compatible with distinct clinical sample types. Key operational parameters, including MB concentration, mixing frequency, and pressure settings, were detailed to facilitate consistent performance. Using this workflow, tumor cell capture rates of approximately 70% in bile (for ETCs) and blood (for CTCs) were achieved, with a total processing time of 60-90&#xa0;min per sample under clinically relevant low-abundance conditions. The platform enables reliable detection of as few as 1 tumor cell per mL of blood or bile. This method provides a practical and adaptable strategy for glycosaminoglycan-mediated liquid biopsy applications and may be extended to other tumor-cell enrichment workflows involving heterogeneous cell-surface interactions.

Humans

Assessment of temporomandibular joint space changes after orthognathic surgery in skeletal malocclusion patients: a systematic review.

PURPOSE: To interpret postoperative changes in temporomandibular joint (TMJ) joint space dimensions and condylar position following orthognathic surgery in patients with skeletal malocclusions, and to determine whether reported alterations represent clinically meaningful displacement or physiological adaptive remodeling. MATERIALS AND METHODS: A comprehensive search of PubMed, SCOPUS, Web of Science, EBSCOhost, and Cochrane Library was performed to assess pre- and postoperative TMJ changes using three-dimensional imaging. Joint spaces including anterior (AJS), superior (SJS), and posterior (PJS) and condylar morphology were evaluated. Methodological quality was appraised using the Joanna Briggs Institute (JBI) checklist. Due to methodological and clinical heterogeneity, findings were synthesized narratively with attention to malocclusion type and surgical movement. RESULTS: A total of 16 studies consisting 628 patients undergoing BSSO, Le Fort I osteotomy, vertical ramus osteotomy, or bimaxillary surgery were included. Most studies reported minor, adaptive postoperative changes in AJS, SJS, and PJS. Class II patients showed more consistent increases in AJS/SJS, whereas Class III patients demonstrated variable posterior or anterior remodelling depending on surgical movement. Volumetric analyses revealed region-specific adaptations without significant condylar displacement. Postoperative temporomandibular disorder symptoms were infrequent, and no consistent evidence supported detrimental TMJ effects attributable to surgery. CONCLUSION: Postoperative TMJ joint space changes after orthognathic surgery primarily represent physiological adaptive remodeling rather than pathological condylar displacement, with reported variability driven by malocclusion type, surgical movement, fixation method, and imaging protocol. Recognizing these predictable patterns is essential to prevent overinterpretation of postoperative imaging and to improve clinical assessment through standardized three-dimensional and long-term evaluation strategies.

Humans

Association Between 24-Hour Blood Pressure and Rates of Retinal Nerve Fiber Layer Progression in Glaucoma: The Vascular Imaging in Glaucoma Study.

PURPOSE: Low systemic blood pressure (BP) has been implicated as a risk factor for glaucoma progression. The purpose of this study was to investigate the association between 24-hour BP and rates of retinal nerve fiber layer (RNFL) loss in eyes with primary open-angle glaucoma. DESIGN: Prospective cohort study. PARTICIPANTS: Seventy-nine eyes from 42 subjects with glaucoma (mean age, 68.5 &#xb1; 7.6 years) enrolled in the Vascular Imaging in Glaucoma Study at the Bascom Palmer Eye Institute. METHODS: Participants underwent 24-hour ambulatory BP monitoring at baseline. Follow-up evaluations were conducted at 4-month intervals and included ophthalmic examination, BP measurement, and peripapillary RNFL thickness measurement with spectral-domain optical coherence tomography. The association between BP and RNFL loss over time was assessed using linear mixed-effects models adjusted for age, sex, race, baseline RNFL thickness, central corneal thickness, and intraocular pressure. MAIN OUTCOME MEASURES: The effect of baseline 24-hour mean arterial pressure (MAP), systolic BP (SBP), and diastolic BP (DBP) on the rate of average RNFL loss over time. RESULTS: Eyes underwent an average of 13 &#xb1; 3 optical coherence tomography exams over 43 &#xb1; 10 months of follow-up. The mean rate of RNFL loss was -0.34 &#xb1; 0.64 &#xb5;m/y (median: -0.32; interquartile range: -0.66 to -0.04 &#xb5;m/y). After adjusting for confounding factors, every 10 mm Hg lower in 24-hour minimum MAP, SBP, and DBP was associated with -0.542 &#xb5;m/y (P < .001), -0.360 &#xb5;m/y (P = .003), and -0.458 &#xb5;m/y (P = .008) faster RNFL loss, respectively. Eyes in the lowest quartile of average 24-hour MAP (81-90 mm Hg) and minimum 24-hour DBP (35-47 mm Hg) experienced significantly faster progression compared to those in the highest quartile, with differences of -0.68 &#xb5;m/y (P = .017) and -0.63 &#xb5;m/y (P = .030), respectively. CONCLUSIONS: Lower systemic BP, especially minimum MAP, SBP, and DBP measured by 24-hour ambulatory BP monitoring, is associated with faster rates of RNFL loss in primary open-angle glaucoma eyes. 24-hour BP monitoring may help predict glaucoma patients at greater risk of progression.

Humans

Impact of Diabetes on Outcomes of Contemporary PCI Guided by OCT vs Angiography: The ILUMIEN IV Trial.

BACKGROUND: Patients with diabetes are at higher risk for adverse events after percutaneous coronary intervention (PCI) compared with patients without diabetes. OBJECTIVES: This study sought to assess the influence of diabetes and complex lesions on the outcomes of patients undergoing PCI with and without optical coherence tomography (OCT) guidance during a follow-up period of 2 years. METHODS: Patients in ILUMIEN IV randomized to OCT-guided vs angiography-guided PCI were grouped into those with (n = 1,044) and without diabetes (n = 1,443). Study endpoints were target vessel failure (TVF) and serious major adverse cardiovascular events (MACE). RESULTS: After adjustment for differences in clinical and angiographic characteristics, the 2-year rates of both TVF (9.9% vs 6.3%; adjusted HR: 1.48; 95% CI: 1.09-2.02; P = 0.01) and serious MACE (5.3% vs 2.7%; adjusted HR: 1.77; 95% CI: 1.14-2.76; P = 0.01) were increased in diabetic compared with nondiabetic patients, consistently in patients with and without complex lesions (Pinteraction = 0.22 and 0.14, respectively), although the highest 2-year rates were in patients with diabetes and complex lesions. In all randomized patients, OCT guidance compared with angiography guidance did not reduce TVF or serious MACE. These effects were consistent in patients with and without diabetes (Pinteraction = 0.41 and 0.20, respectively), and were not modified by treatment of complex lesions. CONCLUSIONS: In the large-scale ILUMIEN IV trial, patients with diabetes remained at increased risk for adverse events after PCI compared with nondiabetic patients despite the use of OCT procedural guidance. Patients with diabetes and complex lesions were at particularly high risk for adverse outcomes after PCI.

Humans

Role of routine surveillance stress testing in patients with or without imaging-guided or physiology-guided PCI.

OBJECTIVE: The optimal follow-up strategy for high-risk patients who underwent imaging-guided or physiology-guided percutaneous coronary intervention (PCI) remains uncertain. We investigated whether routine surveillance stress testing after PCI provides clinical benefit when the procedure is guided by intravascular ultrasonography (IVUS) or fractional flow reserve (FFR). METHODS: In the Pragmatic Trial Comparing Symptom-Oriented vs Routine Stress Testing in High-Risk Patients Undergoing PCI randomised trial, 1706 high-risk patients who underwent PCI were assigned to either routine functional testing at 1 year or standard care alone. In this prespecified subgroup analysis, patients were subsequently categorised according to whether IVUS or FFR was used at the index procedure. The primary outcome was a composite of death, myocardial infarction or hospitalisation for unstable angina over 2 years. RESULTS: Among the randomised population, 74% underwent IVUS-guided intervention and 36% underwent FFR-guided intervention. At 2 years, rates of the primary outcome were similar between routine testing and standard care both in patients treated with IVUS guidance (5.3% vs 6.7%; HR 0.79; 95% CI 0.50 to 1.24) and without IVUS guidance (5.7% vs 3.8%; HR 1.52; 95%&#x2009;CI 0.63 to 3.68; interaction p=0.21). Comparable results were observed in patients with FFR guidance (2.6% vs 3.9%; HR 0.65; 95%&#x2009;CI 0.26 to 1.58) and without FFR guidance (7.0% vs 7.1%; HR 0.99; 95%&#x2009;CI 0.63 to 1.55; interaction p=0.59). Routine functional testing was consistently associated with higher use of invasive coronary angiography and repeat revascularisation, without improvement in clinical outcomes. CONCLUSIONS: Among high-risk patients who underwent PCI, routine surveillance stress testing did not reduce the risk of death, myocardial infarction or unstable angina, regardless of the use of IVUS or FFR at the index procedure. Routine functional testing increased downstream invasive procedures without clinical benefit. These findings support guideline recommendations against routine surveillance testing after PCI. TRIAL REGISTRATION NUMBER: NCT03217877.

Humans

Robotic Needle Insertion for CT-guided Percutaneous Biopsy of Thoracoabdominal Lesions: A Prospective Multicenter Randomized Trial.

Purpose To compare safety and feasibility between a novel CT-guided robotic system and the conventional freehand technique for puncture biopsy of thoracoabdominal lesions. Materials and Methods In this prospective multicenter randomized trial, individuals with suspected lesions were enrolled between July 2023 and April 2024 across three university teaching hospitals and randomized to the robot-assisted group (n = 82) or the freehand group (n = 83). Procedure outcomes included the technical success rate, targeting error, number of CT scans and needle adjustments, puncture time, and complications. Descriptive and inferential statistics were calculated. Results A total of 165 participants (mean age, 60 years &#xb1; 10 [SD]; 83 male) were included. Compared with the freehand group, the robot-assisted group demonstrated a higher technical success rate (97.56% [80 of 82] vs 62.65% [52 of 83], P < .001), lower targeting error (mean Euclidean deviation: 1.7 mm &#xb1; 1.1 vs 4.5 mm &#xb1; 3.9, P < .001), and fewer CT scans (mean, 4.3 &#xb1; 1.9 vs 5.2 &#xb1; 2.3; P = .002) and needle adjustments (mean, 0.7 &#xb1; 0.7 vs 1.6 &#xb1; 1.6; P = .003). Despite differences in geometric precision, both groups achieved 100% (82 of 82 and 83 of 83) diagnostic yield. The median puncture time was comparable between groups (5.5 minutes &#xb1; 4.3 vs 4.8 minutes &#xb1; 7.0, P = .50). During lung biopsies, the robot-assisted approach yielded fewer complications compared with the freehand approach (4.88% [four of 82] vs 16.87% [14 of 83], P = .014). Conclusion Compared with the freehand approach, robot-assisted biopsy yielded greater precision and reduced adjustments and complications while demonstrating noninferior diagnostic efficacy and comparable duration. Keywords: Robotic Needle Insertion, Biopsy, Thoracoabdominal Lesions, Robot-assisted Biopsy, CT-guided Intervention, Percutaneous Needle Biopsy, Randomized Controlled Trial, Algorithm Development, CT, Clinical Testing, Interventional-Body, Biopsy/Needle Aspiration, Percutaneous, Thorax, Abdomen/GI, Liver, Lung, Kidney &#xa9;RSNA, 2026.

Humans

Artificial intelligence for dental caries detection: An umbrella review.

Artificial intelligence (AI) has been proposed as a tool to improve dental caries detection across imaging modalities; however, its clinical value remains uncertain. This umbrella review aimed to synthesize and critically appraise systematic reviews evaluating AI for caries detection and diagnosis. An umbrella review was conducted following PRIOR guidance (PROSPERO CRD420261340728). Searches were performed in MEDLINE, Embase, Scopus, Web of Science, and Google Scholar up to 15 March 2026. Methodological quality was assessed using AMSTAR 2, and overlap of primary studies was quantified using the corrected covered area (CCA). Seventeen systematic reviews were included, of which five reported diagnostic test accuracy meta-analyses using bivariate or HSROC models. Across these meta-analyses, pooled sensitivity ranged from 0.76 to 0.94 and specificity from 0.85 to 0.91. Most systems were based on deep learning models applied to bitewing radiographs and intraoral photographs. However, substantial heterogeneity was observed in imaging modalities, lesion thresholds, analytical tasks, and evaluation metrics. In addition, a high degree of overlap across reviews and recurrent methodological limitations, including reliance on retrospective datasets, limited external validation, and inconsistent reporting, substantially weaken the reliability of the evidence. Although AI models demonstrate high diagnostic performance under experimental conditions, current evidence does not support their use as stand-alone diagnostic tools. Their clinical applicability remains limited, and implementation should be restricted to decision-support contexts until robust prospective validation demonstrates meaningful impact on clinical decision-making and patient outcomes.

Dental Caries

E-cigarette product characteristics and packaging features and interest in e-cigarette use: Results from a randomized within-person trial nested in three prospective cohorts.

BACKGROUND: Product characteristics and packaging may be key targets for regulation to reduce e-cigarette use among youth, but existing data are limited. METHODS: Data are from an experimental study (2018-2020) nested within three prospective cohorts (age 14-26) in southern California (N&#x2009;=&#x2009;3565). Participants were shown five e-cigarette (e-liquid) packages in a random order that varied in flavor (sweet vs. tobacco), flavor name (descriptive ["blueberry cheesecake"] vs. concept ["smurf cake"] vs. none [number only]), and cartoon image on package (yes/no). For each stimuli, survey items assessed the following outcomes: product appeal (self-enjoyment, others' enjoyment; Likert scale [1-5]), susceptibility to use (use if friends offered, curiosity; 4 ordered responses [definitely not-definitely yes]), peer acceptability (definitely not-definitely yes), and perceived harm (definitely not-definitely yes). Mixed effects proportional odds models evaluated within-person effects of each factor (flavor, flavor name, cartoon) with each outcome. RESULTS: Participants reported greater appeal, susceptibility, and peer acceptability (OR range=3.7-16.9; ps<0.05), and lower perceived harm (OR=0.61; 95%CI=0.53, 0.70) for sweet (vs. tobacco-flavored) e-cigarettes; effects were progressively stronger for younger cohorts. The descriptive flavor name rated higher than the concept flavor (OR range=1.13-2.02; ps<0.05) or number only (OR range=1.18-1.69; ps<0.05) for appeal and susceptibility measures; no differences for concept vs. number were found. The cartoon image rated higher for appeal, curiosity, and peer acceptability (OR range=1.24-1.51; ps<0.05). CONCLUSIONS: Sweet flavors, descriptive flavor names, and cartoon images may increase the appeal of e-cigarettes among youth and young adults with no history of e-cigarette use, and are key targets for regulation.

Humans

Ultrasound protocols used to detect vascular gas emboli in divers: a systematic review.

INTRODUCTION: Venous gas emboli (VGE) detected via ultrasound can be used as a surrogate marker for decompression stress. While Doppler ultrasound is the historical gold standard, two-dimensional (2D) ultrasonography offers advantages for on-site monitoring, including a wider field of view and reduced dependence on noise-free environments. This systematic review evaluates 2D ultrasonography protocols used in decompression research since the 2015 International Meeting on Ultrasound for Diving Research, identifying methodological similarities, differences, and adherence to consensus recommendations. METHODS: A search of PubMed and Scopus identified studies using 2D ultrasound to detect VGE in divers. Inclusion criteria were: (1) use of 2D ultrasound, (2) detection of VGE or monitoring of decompression stress, (3) inclusion of a diver cohort, and (4) publication after 2015. Data extraction focused on VGE scoring systems, ultrasound hardware, measurement protocols, and operator experience. Risk of bias was assessed using ROBINS-I-V2, and compliance with the 2015 consensus recommendations was evaluated. RESULTS: Twenty studies were included. The Eftedal-Brubakk scale was most commonly used (n = 15), with cardiac ultrasound as the primary imaging modality; one study assessed a peripheral vessel. Common shortcomings included post-dive measurements lasting less than two hours, underreporting of operator experience and hardware specifications, limited individual-level data, and inappropriate use of parametric statistics for ordinal bubble grade data. No study fully complied with all consensus recommendations. CONCLUSIONS: This review demonstrates that, although two-dimensional ultrasound is widely used for post-dive VGE assessment, methodological heterogeneity with multiple shortcomings remain. Furthermore, nearly all studies restricted imaging to the heart, thus leaving peripheral vessel assessment largely unexplored.

Embolism, Air

Current Concepts and Emerging Technologies in Aesthetic Outcome Assessment of Breast Reconstruction.

Aesthetic outcomes are a crucial determinant of the overall success of breast reconstruction. Recently, aesthetic assessment has evolved from relying mainly on subjective impressions to incorporating more quantitative methods. This systematic review summarizes current concepts and emerging technologies in aesthetic outcome assessment after breast reconstruction. A comprehensive search of studies evaluating aesthetic outcomes following implant-based, autologous or hybrid breast reconstruction was performed between 2000 and 2025. Assessments were classified as subjective or objective. Extracted variables included assessment characteristics, aesthetic outcome domains, and patient-centered outcomes. Risk of bias was assessed using the Joanna Briggs Institute Critical Appraisal Checklist. Levels of evidence were classified according to the Oxford Centre for Evidence-Based Medicine. A total of 51 studies involving 7711 participants from 16 countries were included. Subjective tools were most frequently employed, led by the BREAST-Q (35/51, 69%), followed by expert- or panel-based evaluations (17/51, 33%) and the visual analog scale (2/51, 4%). Objective methods were applied in 19 studies and included 3-dimensional surface imaging (8/51, 16%), BCCT.core (7/51, 14%), eye tracking (3/51, 6%), and artificial intelligence-based analyses (3/51, 6%). Although subjective tools captured satisfaction with breast appearance, objective tools quantified morphological parameters and positional landmarks. BREAST-Q remains the cornerstone of outcome evaluation after breast reconstruction, providing patient-centered perspectives, including, but not limited to, aesthetic perception. A progressive shift toward multimodal evaluation was noticed, as no single modality comprehensively addressed all aesthetic domains. Future research should focus on integrating subjective and objective assessment methods within a unified framework. Level of Evidence: 3 (Therapeutic) For image description, please refer to the figure legend and surrounding text.

Humans

Higher Rates of PASS and SCB After Arthroscopic Subspine Decompression Are Associated With a Positive Diagnostic AIIS Injection: A Propensity Score-Matched Cohort Study.

BACKGROUND: Hip arthroscopy effectively treats femoroacetabular impingement syndrome (FAIS), but persistent pain may be related to concomitant extra-articular pathology such as subspine impingement syndrome (SSI). Standard diagnosis of SSI often relies on 3-dimensional computed tomography (3D-CT) morphology (Hetsroni type II/III), although this morphology is common in individuals who are asymptomatic and correlates poorly with symptoms. PURPOSE: To compare minimum 2-year clinical outcomes after arthroscopic subspine decompression in patients with concurrent FAIS and type II/III anterior inferior iliac spine (AIIS) morphology, stratified by diagnostic method: 3D-CT morphology alone versus 3D-CT morphology plus a positive ultrasound-guided diagnostic injection. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: This study included patients aged 18 to 55 years with type II/III AIIS morphology who underwent primary hip arthroscopy for FAIS and SSI between January 2021 and November 2023 and had minimum 2-year follow-up. Patients diagnosed by CT morphology alone (CT classification group) were propensity score matched 1:1 to patients with a positive ultrasound-guided AIIS injection (injection group), with 57 patients per group. Matching variables were age, sex, body mass index, lateral center-edge angle, alpha angle, T&#xf6;nnis grade, and Beighton score. All patients underwent arthroscopic subspine decompression. Patient-reported outcomes and rates of achieving the minimal clinically important difference, Patient Acceptable Symptom State (PASS), and substantial clinical benefit (SCB) were compared. RESULTS: Preoperative patient-reported outcome scores were similar between groups (all P > .05). At minimum 2-year follow-up, the injection group had significantly better scores on the modified Harris Hip Score (90.8 vs 84.2), Hip Outcome Score-Activities of Daily Living (88.4 vs 82.4), Hip Outcome Score-Sports Subscale (71.9 vs 64.1), 12-item International Hip Outcome Tool (83.9 vs 76.1), and visual analog scale for pain (1.2 vs 2.0) (all P < .001). Minimal clinically important difference rates were high in both groups, with higher rates in the injection group for modified Harris Hip Score (93% vs 77%; P = .033) and Hip Outcome Score-Activities of Daily Living (91% vs 75%; P = .042). PASS and SCB rates were significantly higher in the injection group across all patient-reported outcome measures (all P < .05). Revision and complication rates were low and did not differ significantly between groups. CONCLUSION: Both groups improved significantly after arthroscopic subspine decompression. However, patients with a positive ultrasound-guided diagnostic AIIS injection achieved higher PASS and SCB rates than those selected by CT morphology alone, suggesting that injection-confirmed SSI may improve patient selection for subspine decompression.

Humans

Mitigating pH-induced instability in deruxtecan-based ADCs: an onboard-mixing icIEF approach for robust charge heterogeneity characterization.

Accurate charge variant analysis of antibody-drug conjugates (ADCs) is essential for understanding product heterogeneity and ensuring quality control. However, Deruxtecan (DXd)-based ADCs present a unique analytical challenge due to the intrinsic instability of the payload, where the lactone ring readily undergoes hydrolysis under alkaline conditions, resulting in time-dependent shifts in charge distribution during imaged capillary isoelectric focusing (icIEF). In this study, we describe the development of an onboard-mixing icIEF method designed to minimize pH-induced degradation during sample preparation. By separating ADC samples from carrier ampholytes (CAs) prior to injection and enabling real-time mixing within the instrument, this approach effectively suppresses premature lactone ring opening and stabilizes charge variant profiles. Comparative studies between conventional premixing and onboard-mixing approach demonstrated that the latter significantly enhances reproducibility, particularly for acidic variants that are highly sensitive to structural conversion. Comprehensive method validation confirmed excellent precision, linearity, and sensitivity, with consistent performance across run-to-run and intra-day analyses. The results underscore the importance of controlling microenvironmental pH exposure in the analysis of chemically instable ADCs. The proposed onboard-mixing strategy provides a robust and efficient solution for icIEF-based characterization, reducing analytical artifacts while simplifying method development. This approach is broadly applicable to ADCs and other biotherapeutics containing pH-sensitive functional groups.

Hydrogen-Ion Concentration