Search PubMedSearch

SEARCH · Search PubMed

Results for “ketamine-assisted psychotherapy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

173 records · Page 6Linked to original sources

Evaluation of the difference between automated and measured QTc intervals in children.

BACKGROUND: The corrected QT interval (QTc) is obtained through automated ECG computations or manual physician measurements. We hypothesized that differences exist in children between the measured and automated QTc intervals within and between Healthy and hypertrophic cardiomyopathy (HCM) subjects with greater differences for HCM due to structural abnormalities. METHODS: QT measurements - Bazett correction- automated (aQTc) and measured (mQTc), were extracted from the GE MUSE database for 385 Healthy pediatric (single ECG) and 208 HCM subjects (2 ECGs), stratified by age&#xa0;<&#xa0;12 and&#xa0;&#x2265;&#xa0;12&#xa0;yrs., sex, race, and ethnicity. QTc means (SD), automated and measured differences, and the difference of the differences of aQTc and mQTc were analyzed overall and by subgroups. All ECGs were read by one pediatric cardiologist with a second cardiologist reading a random subset of HCM ECGs to evaluate intraclass correlations and agreement. RESULTS: The mQTc intervals were shorter than aQTc intervals within Healthy (p&#xa0;<&#xa0;0.001) and within first HCM ECGs (p&#xa0;<&#xa0;0.001) with both aQTc and mQTc shorter in Healthy than HCM (p&#xa0;<&#xa0;0.001). The difference in these differences was significant overall using HCM ECG 1 but not HCM ECG 2. Healthy subject aQTc and mQTc intervals differed by age, sex, and race (p&#xa0;<&#xa0;0.002). HCM ECG 1 aQTc- mQTc intervals differed for age&#xa0;<&#xa0;12&#xa0;yrs., as well as by sex and race. HCM ECG 2 intervals differed only for age&#xa0;<&#xa0;12&#xa0;yrs. CONCLUSIONS: Compared to measured values, automated QTc values were significantly longer in both Healthy and HCM subjects. Automated measurements may overestimate the QTc.

Humans

Artificial intelligence enabled social robotic interventions (PARO) in Australian dementia care: A systematic review and meta-analysis.

BACKGROUND: Although there is a growing body of research indicating that Personal Robot/Social Robot could be used in various aspects of care for individuals with dementia, little is known about how well these types of interventions work in an actual hospital setting in Australia. AIMS & OBJECTIVES: The objective of the present systematic review and meta-analysis is to assess the effectiveness of PARO-based socially assistive robotic intervention in terms of its effectiveness outcomes towards the reduction of dementia-related behavioural and psychological symptoms in Australian based healthcare settings. METHODS: A systematic search was conducted across five electronic databases, including MEDLINE (PubMed), EMBASE, CINAHL, PsycINFO, and the Cochrane Library, to identify randomised controlled trials (RCTs) investigating PARO-based socially assistive robotic interventions for dementia in Australian healthcare settings. This review was registered with PROSPERO (CRD420251251916) and followed the PRISMA 2020 guidelines. In addition, the Cochrane Risk of Bias tool (RoB 2) was used to evaluate the risk of bias across all studies. Pooled standardised mean differences (SMD) with 95&#xa0;% confidence intervals (CI) were calculated for agitation, anxiety, and depression. Heterogeneity across studies was evaluated using the I2 statistic. RESULTS: Six RCTs involving 1444 participants were identified for inclusion in this review. AI-enabled socially assistive robotic interventions, specifically the PARO therapeutic robot, significantly reduced agitation and anxiety when compared to standard treatment or control conditions. The pooled analysis showed that agitation [SMD&#xa0;=&#xa0;-0.44 (95&#xa0;% CI: -0.70, -0.18) p&#xa0;=&#xa0;0.0008] and anxiety [SMD&#xa0;=&#xa0;-0.59 (95&#xa0;% CI: -0.91, -0.27) p&#xa0;=&#xa0;0.0003] were reduced significantly, while the decrease in depression [SMD&#xa0;=&#xa0;-0.44 (95&#xa0;% CI: -0.95, -0.07) p&#xa0;=&#xa0;0.09] scores was non-significant among dementia patients receiving PARO-based socially assistive robotic interventions as compared to the control. The overall risk of bias across all six studies was considered low to moderate. CONCLUSION: PARO-based socially assistive robotic interventions may provide preliminary evidence of effectiveness in reducing agitation and anxiety in individuals with dementia in Australian healthcare, but the evidence regarding the reduction of depression remains unclear. Therefore, additional high-quality trials with consistent methodology and extended follow-up will be necessary to determine both the short-term and long-term clinical efficacy and practicality of implementing these interventions into practice.

Humans

Initial 4-Year Experience With Microaxial Flow Pumps Within a Tertiary Centre in Regional Australia.

BACKGROUND & AIM: The Microaxial Flow Pump (MFP) is a miniaturised rotary pump that aspirates blood from the left ventricle and expels it into the ascending aorta. It unloads the left ventricle and increases mean arterial pressure and cardiac output. MFP is most commonly utilised in cardiogenic shock, for protected percutaneous coronary intervention (PCI), and for ventricular offloading in veno-arterial extracorporeal membrane oxygenation (VA-ECMO). METHOD: We conducted a retrospective review of all patients who underwent MFP insertion at John Hunter Hospital, Australia. Categorical data are represented as counts and percentages, with continuous variables described as means with standard deviations. RESULTS: Twenty-three MFP devices were inserted between September 2020 and May 2024. Five (22%) were for protected PCI, three (13%) for venting with VA-ECMO (ECPELLA), and 15 (65%) for acute coronary syndrome (ACS) and cardiogenic shock. The median age for the overall cohort was 62 years, with a 74% male predominance. Eighty percent of the protected PCI cohort were elective outpatient procedures, and there were no deaths in this cohort. The mortality in the ECPELLA group was 67%. Thirteen (87%) of the patients with cardiogenic shock presented with an anterior infarct, and 53% had cardiac arrest on admission. The overall morality in the cardiogenic shock cohort was 40%. Complications in this cohort included limb ischaemia in four patients (17%) and site bleeding in seven patients (30%). Four patients (17%) required vascular surgery intervention. CONCLUSION: Our initial experience showed the use of MFP in a tertiary centre was safe and feasible, allowing progression from protected percutaneous intervention to acute cardiogenic shock.

Humans

RR-interval-based atrial fibrillation detection and burden estimation: cross-dataset validation and calibration-aware probability analysis.

Objective.Atrial fibrillation (AF) burden has become an increasingly important endpoint in long-duration rhythm monitoring, but reliable burden estimation requires more than accurate AF detection alone. In particular, when burden is derived by aggregating predicted AF probabilities over time, probability calibration may directly affect burden validity under external dataset shift.Approach.This study developed an interpretable-interval feature model for AF detection and evaluated it using record-wise cross-validation on a development cohort and independent cross-dataset external validation on public Holter electrocardiographic databases. Window-level performance was assessed using the area under the receiver operating characteristic curve (ROC-AUC), area under the precision-recall curve (PR-AUC), Brier score, expected calibration error (ECE), and calibration intercept and calibration slope. Recording-level AF burden was estimated using both probability-based and hard-label aggregation and evaluated using mean absolute error (MAE) and agreement analyses.Main results.The model showed high discrimination in both development and external evaluation, with external ROC-AUC ofand PR-AUC of. However, external calibration deteriorated despite preserved ranking performance, with Brier score of, ECE(15) of, calibration intercept of, and calibration slope of. In the external cohort, probability-based burden estimation preserved strong association with reference burden but showed weaker raw agreement than hard-label aggregation, with MAE ofversus, consistent with systematic probability underprediction. Repeated external recalibration across record-level splits substantially improved probability quality and probability-based burden estimation. Median probability-burden MAE decreased fromwithout recalibration toafter Platt recalibration andafter isotonic recalibration, while median ECE(15) decreased fromtoand, respectively.Significance.These findings indicate that-interval-based AF detection maintained strong ranking performance in the tested external cohort, but probability calibration should be evaluated explicitly when predicted probabilities are aggregated into AF-burden estimates.

Atrial Fibrillation

Efficacy and Safety of Mechanical Insufflation-Exsufflation in Invasively Ventilated Critically Ill Adults: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.

BACKGROUND: Mechanical insufflation-exsufflation (MI-E) is increasingly used in invasively ventilated adults in the intensive care unit (ICU), yet its therapeutic efficacy and safety remain uncertain due to inconsistent evidence. AIM: To synthesize evidence on the clinical efficacy and safety of MI-E in this population and to examine methodological and clinical heterogeneity underlying reported outcomes. STUDY DESIGN: A systematic review and meta-analysis of randomized studies (including RCTs and randomized crossover trials), conducted following PRISMA guidelines, with risk of bias assessed using the Cochrane risk-of-bias tool. RESULTS: Five randomized controlled trials involving 310 patients were included. Meta-analysis showed that mechanical insufflation-exsufflation (MI-E) significantly increased sputum clearance (SMD&#x2009;=&#x2009;0.63, 95% CI, 0.32-0.93; p&#x2009;<&#x2009;0.00011; I2&#x2009;=&#x2009;38%) without affecting oxygenation (MD&#x2009;=&#x2009;0.28, 95% CI, -0.53 to 1.09; p&#x2009;=&#x2009;0.50; I2&#x2009;=&#x2009;9%). Data on respiratory mechanics, ventilation duration and ICU stay could not be pooled. No serious adverse events were reported. CONCLUSIONS: MI-E significantly improves sputum clearance in invasively ventilated critically ill adults, with no severe adverse events reported in the included studies. Its effects on other outcomes remain inconclusive due to limited data and heterogeneity. Standardized protocols and larger trials are needed. RELEVANCE TO CLINICAL PRACTICE: Clinicians may consider MI-E as an adjunct for respiratory secretion management. Application should be guided by structured patient assessment and individualized parameter adjustment. Future research should standardize interventions and target well-defined patient subgroups to inform clear practice guidelines. TRIAL REGISTRATION: The review protocol was registered in the International Prospective Register of Systematic Reviews, with registration number CRD42023403299.

Humans

Interventions to Reduce Loneliness in Informal Caregivers of People With Dementia: A Systematic Review.

AIM: To summarize the current evidence on reducing loneliness among informal caregivers of people with dementia, such as family members or friends. DESIGN: A systematic review. METHODS: The methodological quality was evaluated using the revised Cochrane risk-of-bias tool for randomized controlled trials and the revised JBI critical appraisal checklist for quasi-experimental studies. Data were extracted as predefined and synthesized narratively. The Template for Intervention Description and Replication checklist was used to report the intervention characteristics. DATA SOURCES: Six electronic databases (MEDLINE via PubMed, EMBASE, Cochrane Library, PsycINFO, CINAHL Plus, and Web of Science Core Collection) were searched for studies published in peer-reviewed English journals from the inception of each database until 28 January 2024. RESULTS: Eight studies were included in this review, published between 2002 and 2023, with three being randomized controlled trials. All included interventions were psychosocial. Only one study reported significant improvements in loneliness. Five studies utilized remote and online interventions, such as social networking, psychotherapy, and online social support. Interventions varied in their impact on secondary outcomes, including stress, depressive symptoms, anxiety, and caregiver burden. Four studies demonstrated a positive effect on caregiver stress levels. One pilot trial reported a positive impact on depressive symptoms, and another study noted potential improvements in anxiety. One pilot study reported an average improvement in caregiver burden. CONCLUSION: While the evidence is insufficient for conclusive statements, this systematic review suggests potential benefits of interventions to reduce loneliness and improve mental health among these caregivers. It highlights the promise of remote interventions in addressing loneliness among dementia caregivers. IMPLICATIONS FOR THE PROFESSION AND/OR PATIENT CARE: The findings suggest that tailored interventions, especially those delivered remotely, can enhance the support provided to caregivers, potentially improving their mental health and overall well-being. REPORTING METHOD: This systematic review adhered to the PRISMA statement. PATIENT OR PUBLIC CONTRIBUTION: No patient or public contribution.

Humans

Post-intervention effectiveness of a computerized personalized cognitive stimulation program adapted according to cognitive reserve in older adults without cognitive impairment in Primary Care: A randomized clinical trial.

BACKGROUND: Cognitive reserve may influence responsiveness to cognitive interventions, yet it is rarely used to tailor computerized stimulation. OBJECTIVE: To evaluate the effectiveness of a computerized cognitive stimulation program personalized according to cognitive reserve on cognition, reserve-related activities, and digital competence in community-dwelling older adults without cognitive impairment in Primary Care. METHODS: In this randomized clinical trial, 102 adults aged &#x2265;65 years with normal cognitive performance were recruited from three primary care centers in Zaragoza, Spain, and stratified by cognitive reserve level before random allocation to intervention or control. The intervention comprised digital literacy sessions followed by 8 weeks of home-based computerized cognitive stimulation tailored to participants' cognitive reserve profiles and life history. Controls received a single group-based health education session focused on maintaining everyday cognitive activity. Outcomes were assessed at baseline and post-intervention using global cognition (MEC-35), the Cognitive Reserve Questionnaire, the Mobile Device Proficiency Questionnaire-16, and domain-specific neuropsychological tests. A total of 100 participants completed the final evaluation and were included in complete-case analyses. RESULTS: Compared with controls, the intervention group showed greater adjusted post-intervention improvements in global cognition (MEC-35 between-group difference: 1.8 points) and several cognitive measures, including temporal orientation, calculation, attention, praxis, verbal fluency, processing speed, executive functions, and verbal learning. CRQ scores and digital competence also improved, with small-to-large effect sizes. CONCLUSIONS: A computerized cognitive stimulation program adapted according to cognitive reserve appears feasible in Primary Care and may improve cognition, engagement in reserve-related activities, and digital competence in older adults without cognitive impairment.

Humans

An automated geometric modeling framework in GATE for the design and optimization of high-sensitivity converging-beam SPECT collimators.

Objective.The trade-off between detection sensitivity and spatial resolution is a fundamental challenge in designing organ-dedicated Single-photon emission computed tomography (SPECT) collimators. While converging-hole geometries offer a solution, their optimization is often hindered by the lack of flexible computational tools capable of modeling large-scale, non-parallel hole arrays. This study aims to develop an automated geometric modeling framework to facilitate the design and evaluation of complex converging- and diverging-hole collimators within standard Monte Carlo environments.Approach.We developed a specialized modeling framework by implementing custom C++ classes and a vector-based alignment algorithm within GATE. This platform enables automated, orientation-consistent construction of large-scale converging arrays not natively supported by standard implementations. A high-sensitivity pure cone-beam collimator (CBC) was designed using this framework. The evaluation used hot-rod, disc, and Jaszczak phantoms for physical characterization, while XCAT and dedicated brain models were employed for clinical tasks, including cardiac, brain perfusion, and DaTscan SPECT simulations.Main results.The CBC achieved a nearly fourfold sensitivity increase compared to a conventional low-energy high-resolution parallel-hole collimator at a 20 cm radius of rotation, while maintaining comparable spatial resolution. Despite a 52.3% field of view reduction, the CBC yielded a 2.2-fold noise reduction (CV: 11.7% vs 25.9%) and mitigated partial volume effects via geometric magnification. XCAT and brain phantom simulations confirmed enhanced anatomical definition and contrast recovery in cardiac, perfusion, and DaTscan tasks.Significance.This work provides an efficient computational tool for rapid design space exploration of advanced collimator geometries. The results demonstrate that the proposed CBC design offers a significant sensitivity advantage, making it highly suitable for high-performance, small-volume clinical applications such as brain and cardiac molecular imaging.

Tomography, Emission-Computed, Single-Photon

Comparison of ultrasound-guided two-point block of the rhomboid intercostal vs. thoracic paravertebral for postoperative analgesia in patients undergoing three-port thoracoscopic surgery: a prospective, randomized, non-inferiority study.

BACKGROUND: The anesthetic characteristics of ultrasound-guided two-point rhomboid intercostal block (RIB) have not been fully established. This study compared the analgesic efficacy of ultrasound-guided two-point RIB with that of two-point thoracic paravertebral block (TPVB) for postoperative pain control and recovery in patients undergoing three-port thoracoscopic surgery. METHODS: Seventy patients aged 18-80&#x2009;years scheduled for three-port thoracoscopic pulmonary resection were block-randomized in a 1:1 ratio to receive either TPVB or RIB. Both techniques were performed using 10&#x2009;mL of 0.5% ropivacaine at each injection site. The primary outcome was the numerical rating scale (NRS) pain score at rest 24&#x2009;h after surgery, with a predefined non-inferiority margin of &#x394;&#x2009;=&#x2009;1. Secondary outcomes included NRS at rest and during coughing at 0.5, 2, 4, 12, 18, 24, and 48&#x2009;h postoperatively, as well as the 24h postoperative Quality of Recovery-40 (QoR-40) score. RESULTS: The final analysis included 34 patients in the TPVB group and 34 in the RIB group. The mean difference in resting NRS scores at 24&#x2009;h between the two groups was 0.088 (95% CI, -0.377 to 0.553), confirming the non-inferiority of RIB. However, the need for rescue analgesia was numerically greater in the RIB group than in the TPVB group (p&#x2009;=&#x2009;0.045). The 24-h postoperative QoR-40 scores and cumulative sufentanil consumption within 48&#x2009;h after surgery were comparable between the groups (both p&#x2009;>&#x2009;0.05). CONCLUSION: Ultrasound-guided two-point RIB provided postoperative analgesia that was non-inferior to TPVB in patients undergoing three-port thoracoscopic surgery.

Adolescent

One Year After a Cyberattack: Lessons Learned and Dosimetric Analysis of Contingency Radiotherapy Plans.

PURPOSE: Cyberattacks on health care institutions pose significant risks to patient care, particularly in radiotherapy departments, which are heavily reliant on digital systems. This study examines the impact of a ransomware attack on our hospital and evaluates the effectiveness of the contingency measures implemented to resume radiotherapy treatments. METHODS AND MATERIALS: Following the cyberattack, our radiotherapy department faced a complete shutdown. After an initial estimate considering a shutdown of several weeks, a contingency plan was executed, including manual patient data retrieval and collaboration with a backup hospital. Contingency plans were prepared and delivered within hours, despite a partial lack of information. These plans allowed some patients to restart treatment 3 days after the attack. A dosimetric analysis was performed for the contingency plans, including various pathologies, mainly glioblastoma, head and neck cancers, and lung cancer. We compared the original and contingency plans in terms of dose coverage to the clinical target volume, biological effective dose, and their clinical impact as assessed at the 1&#x2011;year follow&#x2011;up after the cyberattack. RESULTS: Treatments resumed within 12 days at our hospital. Patients with glioblastoma showed good target coverage because of generous margins, resulting in favorable outcomes. In head and neck cases, the lack of detailed imaging led to significant target volume misses, suggesting that more conservative initial treatments could have been beneficial. Lung cases demonstrated accurate peripheral lesion targeting but faced challenges in central lesions because of the absence of positron emission tomography information. In most cases, the approach of using a contingency plan, even with limited information, led to a higher biological effective dose than would have been achieved if treatment had been stopped until full recovery at our hospital. CONCLUSIONS: The study highlights the critical importance of robust contingency planning in radiotherapy departments, emphasizing the need for backup systems and tailored approaches based on tumor location and available diagnostic information. These lessons emphasize that preparedness for digital disruptions should not focus exclusively on information and technology infrastructure.

Humans

Delphi study robot consenso: Strategies for the implementation of robotic surgery in general surgery in the Spanish hospital network.

INTRODUCTION: The implementation of robotic surgery in public hospitals presents multiple logistical, educational, and organizational challenges. In the absence of unified guidelines, a national consensus is required to optimize its safe and efficient adoption. This study aimed to establish a set of consensus-based and measurable recommendations for the implementation of robotic surgery programs in hospitals within the Spanish National Health System, based on the experience of centres with established robotic programs and intended to serve as guidance for hospitals that are initiating or planning their implementation. METHODS: A national Delphi study was conducted with the participation of robotic surgery experts from 26 public hospitals. The expert panel was composed exclusively of digestive surgeons with experience in robotic surgery. Three iterative rounds of expert panel evaluation were conducted between March 2024 and March 2025. The questions were grouped into five thematic blocks. Consensus was defined as an agreement level of &#x2265;66.7%. Kendall's W coefficient was used to assess concordance. RESULTS: High levels of consensus were achieved on key aspects related to infrastructure, structured training, cost evaluation, and quality assurance mechanisms. Areas of disagreement were also identified, such as the need for a dedicated anaesthesiologist, purchase of accessory instruments during the initial phase, and official accreditation pathways. CONCLUSIONS: This study provides a guideline for developing a national robotic surgery strategy focused on patient safety, program sustainability, and standardized training of surgical teams. These recommendations can guide hospitals at different stages of robotic technology adoption. Given that the consensus was reached from an exclusively surgical perspective, the recommendations focus on patient safety, program sustainability, and standardized training of the surgical team, and should be interpreted in an adaptable manner according to each centre's context, case volume, and available resources.

Cirug&#xed;a Asistida por Robot

Effects of an actuated ankle exoskeleton on walking stability in healthy adults: a controlled laboratory study.

BACKGROUND: Ankle exoskeletons are widely used to reduce the metabolic cost of walking, yet their effects on walking stability during unperturbed gait remain insufficiently understood. Walking stability can be characterized using complementary measures that capture stride-to-stride variability, global temporal organization, and local dynamic stability. Understanding how walking with an actuated ankle exoskeleton system influences these different aspects of gait stability is essential for the safe design and control of wearable robotic devices. METHODS: Eighteen healthy adults walked on a treadmill at a constant speed (1.1&#xa0;m/s) with and without an actuated bilateral ankle exoskeleton in a randomized crossover design. Spatiotemporal variability was quantified using coefficients of variation (CoV) of stride length, step width, and stance ratio. Global gait stability was assessed using detrended fluctuation analysis of stride time. Local dynamic stability was evaluated using maximum Lyapunov exponent calculated for the trunk, hip, upper leg, lower leg, and foot. Paired-samples two-sided t-tests were used to compare conditions. RESULTS: Walking with the ankle exoskeleton resulted in increased stride-to-stride spatiotemporal variability, reflected by higher CoV values for stride length (p&#x2009;<&#x2009;0.001) and stance ratio (p&#x2009;=&#x2009;0.005), while mean stride length and step width remained unchanged. Mean stance ratio was reduced in the exoskeleton condition (p&#x2009;<&#x2009;0.001). Global gait stability did not differ between conditions, indicating preserved long-range temporal gait organization. Local dynamic stability increased at the lower leg (p&#x2009;<&#x2009;0.001) and foot (p&#x2009;=&#x2009;0.019) when walking with the exoskeleton. CONCLUSIONS: Walking with the actuated ankle exoskeleton alters gait control across multiple levels during steady walking. While stride-to-stride variability in stride length and stance ratio increased, global gait stability remained unchanged. Local dynamic stability was increased at the lower leg and foot, suggesting segment-specific effects of ankle-level assistance close to the assisted joint. However, these findings should be interpreted as the combined effect of wearing the exoskeleton and receiving active assistance, rather than the isolated effect of plantarflexion assistance. These&#xa0;results provide insight for the design and control of ankle exoskeletons with respect to stability-related effects during walking.

Humans

Comparative evaluation of molecular technologies for the identification of prevalent non-tuberculous mycobacteria in pulmonary infections: a systematic review and meta-analysis.

BACKGROUND: The increasing prevalence of non-tuberculous mycobacteria pulmonary disease (NTM PD) is a burden to public health. Successful management of NTM PD critically depends on accurate species identification and reliable drug susceptibility testing to guide appropriate antibiotic therapy. Emerging molecular technologies offer rapid diagnostic solutions compared to conventional methods, but their performance varies. This study aims to provide a comprehensive evaluation of current molecular techniques for NTM identification and to present a global antibiotic resistance profile. METHODS: A systematic literature search was conducted in PubMed and Web of Science for studies published between 2005 and 2024. Studies applying molecular methods for NTM identification and resistance detection in humans were included. Data on study characteristics, diagnostic methods, sample types, sample sizes, identification sensitivity, and drug susceptibility results were extracted. Meta-analysis was performed using R with the meta4diag package. The quality of included studies was assessed using the QUADAS-2 tool. RESULTS: The analysis included 49 studies on NTM identification and 33 studies on antibiotic resistance. For species identification, all evaluated molecular technologies (MALDI-TOF MS, PCR-based methods, Sequencing, DNA chip, and DNA strip) demonstrated high pooled sensitivities (>0.92). Subgroup analysis revealed that sample type significantly affected performance for MALDI-TOF MS. Preliminary analysis of antibiotic resistance rates revealed varying patterns. For slowly growing mycobacteria, a significantly high Ethambutol resistance rate was observed in M. avium (69.20%). Among rapidly growing mycobacteria, resistance to Imipenem was notable (54.22%), and Clarithromycin resistance varied significantly within the Mycobacterium abscessus complex. CONCLUSION: Emerging molecular technologies have revolutionized the methodology for NTM identification with excellent performance. However, their performance can be influenced by sample type, particularly for MALDI-TOF MS. The alarming and heterogeneous antibiotic resistance patterns also highlight the critical need for rapid and accurate species identification and drug susceptibility testing to inform effective therapeutic strategies. Key messagesMolecular technologies demonstrate high accuracy for NTM identification.Antibiotic resistance is a serious concern with variations among NTM species and subspecies.Rapid and accurate species identification and drug susceptibility testing are crucial for guiding effective clinical management of NTM PD.

Humans

A STORM-based protocol for nanoscale imaging and quantitative analysis of protein-associated and phospholipid-associated structures in natural rubber.

Stochastic Optical Reconstruction Microscopy (STORM) enables nanoscale mapping of molecular components beyond the diffraction limit; however, its reproducible implementation in hydrophobic polymer matrices remains challenging because fluorescence-labeling specificity, fluorophore photoswitching, three-dimensional localization, chromatic registration, and quantitative image analysis must be carefully controlled. This protocol presents a standardized experimental workflow for dual-color labeling, astigmatism-based three-dimensional STORM acquisition, and quantitative analysis of protein-associated and phospholipid-associated structures in natural rubber (NR). The workflow covers sample pretreatment, Cy5 NHS ester labeling of protein-associated primary amines, DiI labeling of phospholipid-rich domains, STORM imaging-buffer preparation, three-dimensional single-molecule localization, dual-channel registration, generation of standardized xy projections, aggregate-size analysis, and projected lateral spatial correlation assessment. Reproducibility is supported by defined acquisition and localization criteria, three independent sample preparations with at least five fields of view analyzed per condition, and unlabeled, single-color, dye-only matrix, and processing-associated Cy5 controls. Mean lateral localization precisions of 11.8&#x202f;&#xb1;&#x202f;2.3&#x202f;nm for Cy5 and 13.5&#x202f;&#xb1;&#x202f;2.9&#x202f;nm for DiI were obtained, while two-dimensional Fourier ring correlation analysis of the xy projections yielded effective lateral image resolutions of approximately 25 and 28&#x202f;nm, respectively. Image-based particle segmentation and localization-coordinate-based density-based spatial clustering of applications with noise (DBSCAN) were applied to standardized xy projections as complementary quantitative approaches. Application of the protocol to untreated, centrifuged, and protease-treated NR samples demonstrated treatment-associated changes in the detected abundance and projected size distributions of protein- and phospholipid-associated aggregates, together with a non-monotonic change in their projected lateral spatial correlation. These observations describe alterations in nanoscale organization but do not, by themselves, establish stable protein-phospholipid complex formation. Unlike previous studies that primarily demonstrated the feasibility of STORM imaging in rubber materials, the principal contribution of this work is an end-to-end, step-by-step protocol incorporating defined controls, three-dimensional localization, image-quality metrics, chromatic-registration procedures, and complementary quantitative-analysis pipelines for non-expert users. The workflow may be adaptable to other hydrophobic polymers and soft-material systems after appropriate optimization and validation.

Rubber

Diagnostic Performance of Machine Learning for Systemic Lupus Erythematosus: Systematic Review and Meta-Analysis.

BACKGROUND: Early and accurate diagnosis of systemic lupus erythematosus (SLE) and its organ involvement is essential. Previous reviews of machine learning (ML) in SLE combined heterogeneous tasks and validation strategies and may have overinterpreted model performance. OBJECTIVE: This study evaluated the diagnostic performance of ML and deep learning (DL) models for 3 clinically distinct SLE-related tasks: SLE classification or diagnosis, lupus nephritis (LN) diagnosis, and neuropsychiatric systemic lupus erythematosus (NPSLE) discrimination. We also assessed methodological quality and certainty of evidence. METHODS: PubMed, Embase, Cochrane Library, Web of Science, and IEEE Xplore were searched from January 2014 to April 2026. Eligible peer-reviewed diagnostic accuracy studies developed or validated ML or DL models for 1 of the 3 prespecified tasks, used an accepted reference standard, and provided data for a 2&#xd7;2 contingency table. Bivariate random-effects meta-analyses with the Hartung-Knapp-Sidik-Jonkman adjustment were used to pool sensitivity and specificity. We reported 95% prediction intervals (PIs), assessed risk of bias using the Quality Assessment of Diagnostic Accuracy Studies for Artificial Intelligence tool (QUADAS-AI; Viknesh Sounderajah [Imperial College London]), and evaluated certainty of evidence using the Grading of Recommendations Assessment, Development, and Evaluation framework for diagnostic test accuracy. RESULTS: Twenty-nine studies were included: 17 for SLE classification, 5 for LN diagnosis, and 7 for NPSLE discrimination. In the primary task-stratified analysis, pooled sensitivity was 0.91 (95% CI 0.86-0.94; 95% PI 0.56-0.99), and pooled specificity was 0.94 (95% CI 0.91-0.96; 95% PI 0.69-0.99), with low heterogeneity (I&#xb2;=23.9% and 22.9%, respectively). DL models showed a sensitivity of 0.93 and specificity of 0.95, compared with 0.88 and 0.94 for traditional ML models. Certainty of evidence was high for most analyses but low for LN diagnosis because of inconsistency and imprecision. All studies were retrospective, and only 9 of 29 (31%) performed independent external validation. Overall risk of bias was high or unclear in 22 of 29 (75.9%) studies. No study reported model calibration, decision-curve analysis, or net clinical benefit. CONCLUSIONS: ML models showed promising diagnostic accuracy across 3 distinct SLE-related tasks, but wide PIs, limited external validation, and pervasive risk of bias restrict conclusions about real-world generalizability. Prospective multicenter studies with standardized tasks and reference standards, independent external validation, and formal assessment of calibration and clinical utility are required before clinical implementation.

Humans

Five-year outcomes in a randomised controlled trial of prolonged exposure therapy and supportive counselling for post-traumatic stress disorder in adolescents: a task-shifted intervention.

BACKGROUND: Cognitive-behavioural therapies with a trauma focus are effective in reducing posttraumatic stress disorder and other psychological distress in adolescents. Long-term follow-up data on adolescents treated for PTSD remain scarce, with few studies extending beyond 12 months after treatment completion. OBJECTIVE: To evaluate the maintenance of treatment gains in a comparative study of effectiveness of PE-A and SC up to 60 months post-treatment. METHOD: Sixty-three adolescents diagnosed with PTSD were randomly assigned to either treatment, provided by newly trained and supervised non-specialist health workers. The primary outcome measure was PTSD symptom severity, as independently assessed on the Child PTSD Symptom Scale (CPSS). We report on the 60-month post-treatment follow-up, building on post-treatment, 3-month, 6-month, 12-month and 24-month post-treatment data that have been published previously. RESULTS: Participants in both treatment groups maintained a significant reduction in PTSD symptoms up to 60-months post-treatment (F (7, 343)&#x2009;=&#x2009;2.86, p&#x2009;<&#x2009;.01). Participants receiving prolonged exposure experienced greater improvement on the CPSS at all follow-up assessment timepoints, except for the 60-month FU (p&#x2009;=&#x2009;.28; g&#x2009;=&#x2009;0.33). CONCLUSION: Adolescents with PTSD continued to maintain treatment gains up to 60-months post-treatment. These data, along with findings from the original RCT, indicate that a brief treatment protocol (averaging 9 sessions of PE-A or SC) in a LMIC, task-shifted to be delivered by nurses without prior psychotherapy experience, led to lasting improvements in PTSD and comorbid symptoms for up to five years. The sustained benefits and improved functioning over the first few years post-treatment support expanding both treatments, especially PE-A, in community settings.

Humans

Changes in hippocampal functional connectivity and volume associated with cognitive improvement and decline in amnestic mild cognitive impairment following computerized cognitive training.

BACKGROUND: The hippocampus influences the outcomes of amnestic mild cognitive impairment (aMCI) and undergoes different changes during the cognitive decline or recovery of aMCI compared to elderly individuals with normal cognition, which may reveal disease-dependent neurodegeneration or plasticity. We first aimed to investigate the hippocampal changes associated with cognitive changes in aMCI using a combined case-control study design. METHODS: In total, 50&#x202f;aMCI individuals and 50 healthy controls (HCs) were recruited in Shenyang, China, and separately randomized into training and control groups: aMCI training group, aMCI no training group, HC training group, and HC no training group. The aMCI and HC training groups received computerized cognitive training (CCT) thrice weekly for 12 weeks. Cognitive assessments and MRI data were collected at baseline and follow-up. RESULTS: The primary outcome was significant CCT&#xd7;diagnosis interaction effect on the change in cognitive performance as measured by clock drawing test (CDT) scores (F&#x202f;=&#x202f;4.322, P&#x202f;=&#x202f;0.041); this interaction was driven by CCT specifically in aMCI (F&#x202f;=&#x202f;4.465, P&#x202f;=&#x202f;0.038). Significant CCT&#xd7;diagnosis interaction effects of right-hippocampal FC changes were observed in the bilateral precuneus/cuneus (Pvoxel<0.05) driven by CCT in aMCI (F&#x202f;=&#x202f;5.429, P&#x202f;=&#x202f;0.023), and in the left superior temporal gyrus/middle temporal gyrus (STG/MTG, Pvoxel<0.05), driven by CCT of only in HCs (F&#x202f;=&#x202f;6.587, P&#x202f;=&#x202f;0.013). A significant interaction effect of left-hippocampal FC changes were observed in the right triangular part of the inferior frontal gyrus (IFGtriang, Pvoxel<0.05), driven by CCT in aMCI and HCs (F&#x202f;=&#x202f;6.550, P&#x202f;=&#x202f;0.013; F&#x202f;=&#x202f;7.097, P&#x202f;=&#x202f;0.010). No significant interaction effect on the change in hippocampal GMV was noted (P&#x202f;>&#x202f;0.05). CONCLUSION: CCT can improve the visuospatial ability of aMCI, which is reflected by the CDT scores. CCT can alter hippocampal FC in the bilateral precuneus/cuneus, the right IFGtriang, and the left STG/MTG. The hippocampal GMV is difficult to change in both HCs and aMCI during the cognitive decline. REGISTRATION NUMBER: ChiCTR1900026849. DATE OF REGISTRATION: 24 October 2019 NAME OF TRIAL REGISTRY: Chinese Clinical Trial Registry (ChiCTR).

Humans

Evaluation of a cornea-specialized large language model for diagnostic and management accuracy in complex corneal cases.

PURPOSE: To evaluate whether a cornea-specialized large language model (LLM) enhanced with retrieval-augmented generation (RAG) improves clinicians' diagnostic and management accuracy in complex corneal cases compared to a general-purpose GPT-4o model and unaided clinician performance. METHODS: This prospective, randomized, masked evaluation study involved three cornea trainees who each independently reviewed 39 real-world corneal cases under three experimental conditions: unaided, GPT-4o-assisted, and assisted by a cornea-specialized GPT-4o model. The cornea-specialized model was constructed by embedding over 200 publicly available Wikipedia articles into GPT-4o's RAG framework. Participants provided open-ended diagnoses and selected the next-step management options (multiple choice). They were allowed up to three GPT-4o queries per case, and the AI-assisted arms were randomized to minimize bias. Accuracy for both tasks was compared against expert reference standards using McNemar's test. RESULTS: Diagnostic accuracy was 48.7%, 20.5%, and 38.5% unaided, improving to 69.2%, 46.2%, and 59.0% with general GPT-4o (p<0.04). The cornea-specialized GPT-4o further improved accuracy to 71.8%, 48.7%, and 74.4%, with improvements over unaided performance for all clinicians (p<0.01). For next-step decisions, unaided accuracy was 76.9%, 87.2%, and 59.0%. With the specialized model, Ophthalmologist 3 improved to 71.8% (p<0.05), Ophthalmologist 1 remained high at 82.1%, and Ophthalmologist 2 declined to 64.1% (p<0.05). CONCLUSIONS: A cornea-specialized LLM enhanced with RAG improved diagnostic accuracy in complex corneal cases, particularly among clinicians with lower baseline performance. Effects on management accuracy were inconsistent. Future studies should explore the use of open-ended management tasks and examine whether smaller, curated retrieval corpora yield better model performance.

Humans